SmartZone Gateway-Enabled MSPO Series Rack PDU
Contents
1. Before installing your PDU ensure that it has been inspected If the product has any vis ible signs of damage please contact Panduit customer support at 800 777 3300 or cs panduit com Please register your product to receive notification of firmware and product updates at http bit ly 1aXKhr1 Plug Connection This product is intended to be connected by the customer and must be installed by a competent person in compliance with all local and national regulations Hardwiring This product is intended to be hardwired by the customer It must be installed by a qual ified electrician in compliance with all local and national regulations 1 To install the power cable remove the securing screws on the removable user panel 2 Connect the conductors to the rack PDU terminals in line with the terminal mark ings provided Gateway Enabled MSPO Series Rack PDU User Manual 3 Ensure that the cover is replaced and secure before commissioning Vertical Mounting Panduit recommends using the provided external grounding stud for supplementary ground bonding to the rack metalwork 1 Insert the tool less mounting buttons into the fixing holes on the back of the rack cabinet 2 Install the PDU using the bracket mounting buttons and the mounting brackets loc ated at either end of the PDU 10 Gateway Enabled MSPO Series Rack PDU User Manual 11 Gateway Enabled MSPO Series Rack PDU User Manual Hor
2. E24 Gateway User Manual e SmartZone EP042 Gateway User Manual e SmartZone EPA064 Gateway User Manual e SmartZone EPA126 Gateway User Manual 21 Gateway Enabled MSPO Series Rack PDU User Manual Appendix A Temperature Sensor Adapter Installation Follow the instructions below to install the ZAHTLADT 02 v1 01 01 temperature sensor adapter module This adapter allows legacy sensors to provide more accurate tem perature readings Note This adapter does not work with the ZETHL 14 temperature sensor New Installations Follow these instructions when you are installing a standard temperature sensor but the upgraded sensor input is required 1 Plug the adapter directly into the back of the gateway at the sensor port to be used for temperature 2 Plug the temperature sensor connector into the adapter 3 Update the gateway firmware to the latest release See Hardware for details 299 Gateway Enabled MSPO Series Rack PDU User Manual Existing Installations Follow these instructions when the sensor is already installed along with the gateway 1 Unplug the current temperature sensor from the gateway noting the location where it resided 2 Insert the adapter into that location 3 Plug the sensor into the end of the adapter 4 5 The gateway firmware must be updated to the latest firmware See Hardware for Perform these steps for all other temperature sensors to be changed details
3. e Appropriate local AC power receptacle to power the PDU e Local active Ethernet port to communicate with the PDU Safety Precautions This section contains important safety and regulatory information that should be reviewed before installing and using the Rack PDU Servicing There are no user serviceable parts inside these products Any maintenance or repair must be performed by approved service trained personnel Opening the unit will void the product warranty Product Safety Warnings A Warning Use only in dry locations Indoor use only PDU hardware has an International Protection Rating of IPX0 The installer must connect the power distribution unit to an electrical supply that has a protective Earth conductor For pluggable equipment the socket outlet should be installed near the equipment and should be easily accessible A Warning For permanently connected equipment a readily accessible disconnect device should be incorporated external to the equipment Rack PDUs must be protected by a branch circuit protective device rated at the max imum rating of the product specified on the product rating label To avoid risk of overload do not plug additional multiple outlet power distribution devices into the power distribution unit socket outlets This equipment is intended only for installation and use in a Service Access Location in accordance with the following installation and use instructions This equipment is designed
4. Existing Installations AAA A A II 23 Fitting the Adapter iMac 23 Gateway Enabled MSPO Series Rack PDU User Manual SmartZone Gateway Enabled MSPO Series Rack PDU Gateway Enabled MSPO Monitored and Switched Per Outlet Series Rack PDUs man age and distribute power to multiple power devices through a single power connector This PDU allows you to access configure and manage power consumption and envir onmental parameters from remote locations The MSPO Series PDU monitors per phase power voltage and current per outlet power voltage and current per branch current and includes the ability to switch the power to each outlet off or on SmartZone Gateway Enabled PDUs are available in a wide range of configurations and power connections and outlets _ and can be mounted vertically or horizontally Contacting Panduit For Technical Support on PDU hardware and associated software please contact Pan duit Technical Support using one of the following methods 1 866 721 5302 toll free Monday Friday 7 30 am 5 00 pm CST systemsupport panduit com Symbols Used Description Danger Electric Shock Hazard A Warning Possible Safety Hazard Primary Earth Ground Gateway Enabled MSPO Series Rack PDU User Manual Description Gateway Enabled MSPO Series Rack PDU User Manual Equipment Overview The power inlet cord s connects the PDU to the electrical power source The LCD dis plays the current
5. Series Rack PDU User Manual Model Numbers The following table lists the specifications for the Gateway Enabled Rack PDU model numbers Horizontal IQ Adapter HC wwwVxxA IM wwwVxxA HD wwwVxxA IL wwwVxxA HL wwwVxxA Single Inline HM wwwVxxA GM wwwVxxA HP wwwVxxA GL wwwVxxA HS wwwVxxA Dual Inline Vertical LM wwwVxxA VC wwwVxxA LL wwwVxxA VD wwwVxxA Quad Inline VL wwwVxxA AM wwwVxxA VM wwwVxxA AL wwwVxxA VP wwwVxxA Under the Floor VS wwwVxxA UM wwwVxxA In the tables above www is the voltage for single phase or 3 phase and xx is the pos sible current associated with the voltage Refer to the chart below for valid International and U S values International U S Voltage Voltage Current 10 13 16 20 30 15 20 30 50 240 415 32 48 63 120 208 60 80 Gateway Enabled MSPO Series Rack PDU User Manual Pre Installation The Gateway Enabled Rack PDU products covered by this guide are designed to be installed within EIA racks and cabinets Use of this product in other applications is acceptable but other precautions may be required to allow for specific installations not covered by this guideline Gateway Enabled MSPO Series Rack PDU User Manual Installation The Gateway Enabled Rack PDUs are designed to be installed within 19 rack cabinets Use of this product in other applications is acceptable but other precautions may be required to allow for specific installations not covered here Product Inspection
6. a metallic item such as a paper clip is not recommended as a reset tool The reset tool should be inserted perpendicular to the surface of the device and pressed until the button is reached and is actuated The reset tool should bump into the button within 1 8 of an inch of being inserted and should be lightly depressed and held for at least 1 second The reset tool should never be inserted more than 1 4 of an inch Resetting the PDU device starts the bootloader Wait between 1 and 30 seconds for the Display Backlight to blink on and off at a rate of 2 blinks per second The bootloader stays in this mode for at least 4 seconds 8 blinks if no user operation is detected 47 Gateway Enabled MSPO Series Rack PDU User Manual Mode Button Operation Bootloader Startup When the user presses and holds the Mode button the Display Backlight switches to one blink per second indicating the bootloader is waiting for one of the following oper ations e Ifthe user releases the Mode button after two blinks the backlight goes solid on and stays in the bootloader entering the firmware recovery mode See the Firm ware Recovery Mode section below for more details e Ifthe user releases the Mode button after four blinks the backlight goes solid on and attempts to boot the backup firmware image e Ifthe user does not operate the Mode button as described above the Display Back light is turned off The firmware updatable ap
7. to be installed on a dedicated circuit 14 Gateway Enabled MSPO Series Rack PDU User Manual e The dedicated circuit must have circuit breaker or fuse protection e Rack PDUs have been designed without a master circuit breaker or fuse to avoid becoming a single point of failure It is the customer s responsibility to provide adequate protection for the dedicated power circuit Protection of capacity equal to the current rating of the Rack PDU must be provided and must meet all applicable codes and regulations In North America protection must have a 10 000A interrupt capacity A Warning Always disconnect the power supply cord before opening to avoid elec trical shock Pans DANGER High leakage current Ground connection is essential before con necting supply Passe DANGER Double Pole Neutral Fusing The plug on the power supply cord must be installed near the equipment and must be easily accessible Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment gen erates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio com munications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expe
8. Before the adapter is fitted After the adapter is fitted Fitting the Adapter In line This procedure is not recommended but it may be the only solution in some cases ae Gateway Enabled MSPO Series Rack PDU User Manual 1 Using a patch lead from the gateway and an RJ45 Jack to Jack through connector on its non gateway end plug the adapter RJ45 Plug into the through connector 2 Plug either the RJ45 plug of a temperature sensor into the jack on the adapter or a patch lead with the temperature sensor on the end 24
9. PANDUIT SmartZone Gateway Enabled MSPO Series Rack PDU User Manual Release 1 0 Issue 1 0 Gateway Enabled MSPO Series Rack PDU User Manual Copyright 2014 Panduit Corp All rights reserved No part of this book shall be reproduced stored in a retrieval system or transmitted by any means electronic mechanical photocopying recording or otherwise without written permission from Panduit No patent liability is assumed with respect to the use of the information contained herein Although every precaution has been taken in the preparation of this book Panduit assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from the use of the information contained herein Gateway Enabled MSPO Series Rack PDU User Manual Table of Contents SmartZone Gateway Enabled MSPO Series Rack PDU ooo 4 Contacting Pan E e dedos Audi abu td edaseh acy Jasna 4 SyMDOISUSEA ed sane oral Bottle A dade Nadal adnan s EERS 4 Equipment Overview occ o oo ccc cece ec ec ec ALADA LALALE DLE LLL LLa nann 6 BOX COMEMS A e e ta o A ed eo len DIA od a e ae Boulet eno 6 Cable Detalls escote hontai ido bes ce rote some 6 Model Numbers sioc22 3 2 cch cue dute e liada 7 Pr nstallation AA ses aonb a megse A 8 Installati n tone oes rt boca ities do da Cuesta sneak e aoe 9 ole ea eo AAA toe ee Joke tos dA E hate RiP a 9 Plug Connection lt 5 oat vagi ata cela iat as A Sate aan 9 Eo fice lta seid ares Gee il ie l
10. e ices Avene A A See 9 Vertical Mounting axes cece 2tcce soc ed IAS A O 10 Horizontal Mounting 0 c22 eee ri ii Je duce lola det 12 SmartZone 1RU Inline Meters 0 0 2 o coco c cece cece ec ececececeeeeceeeeeeeees 12 Optional Accessories cr E EA SS oats oa seen Te es 13 Additional Required Mes sitio lis e ek ash el gis tt 14 Safety Precautions id A iaa 14 e E E E ESR 14 Product Safety Warnings 220 2 1 s 4cc o dd el 14 RUS e a e El edite e el a ded 15 Environmental Specifications ooooooococccccccccccccccccccocococococcccccononononinicicicns 16 o A A A AA IA 16 HAL Ware 2 e o o e dd o o e e 17 E O IA 17 Reset BUON uea then a een Geel tate ik tw eh at e oa dd GO 17 Mode Button Operation licor ista cc aah o tia es eed ae Ee ie sk ees 18 BO IAEA SATU e nd ip da 18 Firmware Recovery Mode o ocococcococcococcccononcononccnoncoconcnconcncononccncncccincnics 18 Application Startup a e e enn bo RE LEN tek wR La aaa ARES 18 Internal Error Notification 0 0 0 22 2 2 c coco ccccccccc ec ccoo cc ccccececececeeeceeeeeeees 19 Gateway User Interface ooo ccoo coco coco ee ees 20 Access the PDU Graphical User Interface 0 0 00 o occ c cece cece eee ec cece cece ee 20 Using the PDU Graphical User Interface oooococcccccccccccnccccccccnccocnccnonino 21 Appendix A Temperature Sensor Adapter Installation 22 New TS Fea alonso a es a e ope hh ae e eel ea Saag Nd 22
11. izontal Mounting To mount this product horizontally use the RU mountings via the brackets found at either end of the PDU with the provided accessory screws listed below e Horizontal Models North American units 4 10 32 x 1 2 MOUNTING SCREWS 4 12 24 x 1 2 MOUNTING SCREWS Global units 4 M6 x 20mm MOUNTING SCREWS 4 12 24 x 1 2 MOUNTING SCREWS ojoo ooencse O DO O OD O OO 0O 0n 5 00 o 00 o om ooonoo0oojo SmartZone 1RU Inline Meters Install this product to the racks frame via the mounting plate holes found at either end of the PDU using the provided mounting hardware The mounting plate can be adjusted as shown below 12 Gateway Enabled MSPO Series Rack PDU User Manual Optional Accessories Temperature Sensor External Temperature Sensor Humidity Sensor Temperature Humidity Sensor Water Contact Sensor Water Rope Sensor Air Flow Sensor Shock Sensor Digital Input Sensor Passive Infra Red PIR Sensor Door Contact micro switch Door Contact magnetic Standard Electronic Swing Handle Kit Smoke Detector Differential Pressure Transducer Flashing Beacon with Sounder Flashing Beacon with no Sounder HID Access and Control Card Reader Keypad Kit LCD Display Module with Selector Switches PCB only External LCD Display 13 Gateway Enabled MSPO Series Rack PDU User Manual Additional Required Items e Flathead and Phillips screwdrivers
12. load for each input feed or electrical phase per input feed Box Contents The SmartZone Gateway Enabled Rack PDU box contains the following Gateway Enabled Rack PDU Configuration Cable CD Mains Adapter External Grounding Stud Cable Details e 63A single and three phase feed cable 10mm 0 40 inches conductors HO7 cable type terminated with 1P 3 pin 63A commando and 3P 5 pin 63A com mando IEC60309 e 32A single and three phase feed cable 6 0mm 0 23 inches conductors HO7 cable type terminated with 1P 3 pin 32A commando and 3P 5 pin 32A com mando IEC60309 e 16A single and three phase feed cable 2 5mm 0 10 inches conductors HO7 cable type terminated with 1P 3 pin 16A commando and 3P 5 pin 16A com mando IEC60309 13A single phase feed cable 1 5mm 0 06 inches HO7 cable type ter minated with 3 pin UK plug 10A single phase feed cable 1 0mm 0 04 inches HO7 cable type ter minated with 3 pin IEC C14 Plug For IEC C 20 inlet PDUs a customer supplied cord is used for connection to the power source The connection end to the PDU has an IEC C 19 plug for connection to the PDU The opposite end of the cord shall have a plug suitable for connecting to the cus tomer supplied receptacle The cord and plug shall be rated for 20A in North America and 16A outside of North America The connection to the PDU should be made prior to connecting to the power source Gateway Enabled MSPO
13. nse Changes modifications not approved by the responsible party could void the user s authority to operate the equipment 15 Gateway Enabled MSPO Series Rack PDU User Manual Environmental Specifications Operating Temperature OC to 40C Transportation Temperature 10C to 70C Operating Humidity 15 to 85 non condensing Transportation Humidity 5 to 90 non condensing Bonding This product contains an external earthing screw with a star washer which should be used for supplementary Earth bonding to the rack metalwork Bonding pranaicudrg32a i2AWS pana incudrg sa SAW dp tanaincudrga0a pAWo Over 16A less than or equal to 40A Over 40A less than or equal to 63A 16 Gateway Enabled MSPO Series Rack PDU User Manual Hardware LCD Display The display shows the firmware version number device model number serial number MAC Address IP Address and electrical readings The display automatically scrolls through the readings which include e Start Up messages e Configuration serial product number messages e Error Status messages Aggregate data e Single Phase data 3 Phase Delta data or 3 Phase Wye data e Branch current data if the unit has breakers During normal operation the mode button may be used to quickly advance through the LCD display pages Reset Button Push the Reset button using a non metallic item similar in size to a paper clip to reset the PDU device AN Warning
14. plication image continues loading Firmware Recovery Mode The Gateway Enabled PDU provides a firmware recovery mode in case a firmware update is interrupted while in progress and fails to complete successfully Note Do not power cycle or restart a device while a firmware update is in progress If a firmware update does not complete successfully and the device fails to be oper ational after 30 minutes contact Panduit Technical Support 1 866 721 5302 toll free Monday Friday 7 30 am 5 00 pm CST systemsupport panduit com Application Startup When the application is ready a message is displayed on the LCD Starting up The display backlight blinks quickly three times and remains lit The LCD then displays Hold MODE button to reset to defaults 18 Gateway Enabled MSPO Series Rack PDU User Manual The application stays in this mode for at least five seconds If no button operation is detected the application continues to normal system operation If the customer presses and holds the Mode button for five seconds the following mes sage displays on the LCD Hold MODE button more than 5 seconds to reset to defaults If the customer continues to press and hold the Mode button the following message dis plays on the LCD Reset to defaults is detected Please release MODE button The customer should release the Mode button at this point The following message dis plays on the LCD Device is Reset
15. ss 192 168 0 253 TPv4 Network 255 255 255 0 IPv4 Gateway 192 168 0 1 If the device has firmware revision 2 3 04 or later DHCP is the default and one of the following scenarios will be used e If you have a DHCP Server available connect to the appliance through that server using the PDU s IP Address Note The IP address for the Rack PDU is displayed on the device s LCD screen after the label IPv4 e lf you do not have a DHCP server you can run one on your PC To connect to the device use the IP address displayed on the LCD screen e lf you want to use automatic IPv4 address configuration you must activate DHCP on your PC and then connect directly to the PDU This will give you an address on the 169 254 0 0 16 network You can then connect directly using the IP Address displayed on the LCD screen Access the PDU Graphical User Interface To access the GUI open a web browser and enter the IP Address of the PDU When the login page opens you will be prompted to enter a login and password 20 Gateway Enabled MSPO Series Rack PDU User Manual PANDUIT Username Password Login Serial Number 16403 Firmware 1 10 18 The default login and password are Login admin Password admin After successful login the GUI opens to the Overview page Using the PDU Graphical User Interface For detailed information on working with the GUI refer to the appropriate SmartZone Gateway User Manual e SmartZone
16. ting to factory defaults If the customer does not operate the Mode button as described above the application continues normal system operation Internal Error Notification After system start up is complete the LCD screen may blink during normal operation of the unit This typically indicates a temporary or persistent internal error condition If the condition is persistent the LCD screen displays the word STATUS followed by a hexadecimal code similar to the following STATUS 0x009000080 The hexadecimal code is a composition of per outlet control per outlet monitoring and per phase monitoring status For example if a three phase Per outlet Monitoring or Switched unit loses a power phase the status screen will reflect that communication to those boards has been lost For definitions and recommended actions on status codes provide the displayed hexa decimal number to Panduit Technical Support 19 Gateway Enabled MSPO Series Rack PDU User Manual Gateway User Interface The SmartZone Gateway Enabled Rack PDU provides access to configuration power and sensor data through the Gateway Graphical User Interface GUI using a standard browser There are several ways to connect to the device s Gateway GUI depending on your network configuration and the firmware revision of the device If the PDU has firmware revision 2 3 03 or earlier Static IP is the default The con figuration settings in this case are IPv4 Addre
Download Pdf Manuals
Related Search
Related Contents
HP Compaq dc7800 Base Model Ultra-slim Desktop PC ISO-TECH IMT-3300 Instruction manual Manuel d`instructions Quick Start Guide & Installation manual Guide de d`emarrage et Olympus 227590 User's Manual SID User Manual November 2012 MICROTHIOL® SPECIAL LÍQUIDO Canada - Buyandsell.gc.ca 平成 21 年度委託業務 「木材表面刺傷装置」の設計・製作 Copyright © All rights reserved.