Home
Racks P7C Controller – HI tecnologia
Contents
1. connections Keep the equipment away from water Do not use it if wet Avoid the overheating Unwind the cable and do not cover it with any material Do not superimpose drag or put objects above the cable AC Rack PWS800 Terminal Con Signal nector 1 AC 2 AC 3 Ground DC Rack DCC850 Terminal Signal Connector 1 5 2 3 Ground 1 Check the Notes and Acronysms List at the beggining of this document Technical Specifications Ref PMU107001 Version 1 0 07 Release 10 20 10 34 EX Hi tecnologia User Manual P7C Controller IMPORTANT The main Rack MRK AC power supply can be from 85 to 265 VAC or 100 to 400 VDC The main Rack MRK DC power supply can be from 10 to 36VDC We recommend the use of a rigid or flexible 2 5mm2 wire 7mm stripped or flexible 1 5mm2 wire with eyelets terminal Earth Protection Connector Note The modules can have lever connectors for the new modules or screw connectors IMPORTANT Use connector Faston 6 3 totally isolated for 1mm2 green and yellow cable This connection with the rack can be made at the bottom side on the top side or both ways Addressing Racks addresing The expansion racks are coupled on the main rack right side being possible to couple up to five expansions Each rack has a three straps set named J1 J2 J3 This set placed at the backplanes between the connectors of the third and fourth slots must be c
2. RA z HI tecnologia RA Automac o Industrial Racks P7C Controller HI tecnologia The content of this document is part of P7C User Manual PMU1070011 The Notes and Acronyms full list is at the complete version of the manual To get it please access www hitecnologia com br User Manual P7C Controller Ref PMU107001 FN EXI HI tecnologia tecnologia Automa o Industral Technical Specifications Presentation P7C programmable controllers line was developed for attending machine and process control ap plications This PLC has up to 368 I O points at its full configuration and offers all the others HI con trollers versatility including also new and exclusive features Its design is based on expansible racks supporting up to 4 hardware modules per rack The basic configuration is composed by a main rack with power supply and capacity up to 4 modules On the other hand the Full configuration can be composed by 1 main rack 5 expansion racks providing 24 slots for use The racks interconnection must be done always on the right side of the rack using the connector placed at the backplane Main Rack oR a Siinnly Module ee CPU Module Expansion Rack Termination Module Modules Free Slot Note The modules can have lever connectors for the new mod ules or screw connectors 1 Check the Notes and Acronysms List at the beggining of this document Technical Specifica
3. ad performance or damages to the product Picture A Screw Picture B Locks Screws Picture C Connection 1 Check the Notes and Acronysms List at the beggining of this document Technical Specifications Release 10 20 10 33 Version 1 0 07 Ref PMU107001 ay HI tecnologia gt Industrial User Manual P7C Controlle E _____ S Supply The power supply connector is a spring connector that does not need a screw to be tightened To insert the wire in the terminal block use a screw driver at the smaller hole as indicated by A at the following picture Push the screw driver until open the spring as indicated by letter B at the following picture and after insert the wire in the corresponding terminal block After this procedure remove the screw driver and make sure the connection was completed correctly To remove the wire is pos sible to execute the same procedure indicated by letters A and B of the following picture ATTENTION Electric shock danger the bad utilisation may result in fire or death Read and follow the instructions indicated at this manual Make sure that the cables which will be connected to the power supply are disenergized be fore any operation Inspect the cable before each utilisation Do not use if the cable is damaged Insert the cable completely into the terminal block Do not use excessive force to make the
4. gree Dimensions 10 to 36 VDC automatic 30 Watts m x 0 to 60 C 25 C to 80 C lt 90 without condensation 1 0 Kg approximately Aluminium and Carbon Steel IP30 150 L x 110 A x 115 P mm Technical Data Expansion Rack 300 107 200 100 Power Supply Consumption Operating temperature Storage temperature 1 Check the Notes and Acronysms List at the beggining of this document Supplied by main rack O to 60 C 25 C to 80 C Technical Specifications Ref PMU107001 Version 1 0 07 Release 10 20 10 32 as Tike ologia User Manual P7C Controller Humidity lt 90 without condensation Rack weight 0 5 Kg Box Aluminium and Carbon Steel Protection Degree IP30 Dimensions 110 W x 110 H x 115 P mm Maximum number 5 expansion racks Racks connection The expansion racks must be connected to the right side of the main rack In the case of adding one expansion rack it is necessary to remove the screw place at the main rack side Picture A and loosen the two screws placed on the rack back side in order to fit the red locks as shown on the picture Picture B and there the connection will be made For that approach both racks in order to fit the locks and connectors together Push both screws M3x4 to fix the two locks as Picture C shows IMPORTANT Note the perfect racks connection they must be aligned after the correct con nection The incorrect connection may result in b
5. onfigured according to the position of the rack using jumpers as the following Identification Main Rack OFF OFF OFF Expansion Rack 01 ON OFF OFF Expansion Rack 02 OFF ON OFF Caption Expansion Rack 03 ON ON OFF P per OFF without jumper Expansion Rack 04 OFF OFF ON Expansion Rack 05 ON OFF ON Caption 1 Check the Notes and Acronysms List at the beggining of this document Technical Specifications Ref PMU107001 Version 1 0 07 Release 10 20 10 35 EX HI tecnologia User Manual P7C Controller Main Expansion 01 Expansion 02 Expansion 03 Expansion 04 Expansion 05 Note The modules can have lever connectors for the new modules or screw connectors Termination Module BBT260 The termination module must be obligatorily connected to the last expansion rack or if it does not exist then it must be connected to the main rack IMPORTANT The equipment does not work without the termination module The module can not be connected and or disconnected with the equipment turned on Make sure the equipment is turned off before any opperation Fixing the Rack on trails To fix the rack on the trail is necessary to fit the rack lower part as indicated by number 1 at the picture pushing from the bottom to the top To put the rack in the trail just fit the lower part of the rack as indicated by number 1 at the picture pushing to the top and at the direction of the trail as indicated by numbe
6. r 2 at the picture 1 1 Check the Notes and Acronysms List at the beggining of this document 2 Technical Specifications Ref PMU107001 Version 1 0 07 Release 10 20 10 36 aes F HI tecnologia FS J User Manual P7C Controller Ea Automa o Industrial Removing the rack from trails To remove the rack from the trail just push it to the top as indicated by number 1 at the picture and also move it to the front as indicated by number 2 at the picture Dimensions mm Main Rack FEF 123 31 ST ET Dg hed d bead bead head bead bed lalallala alealyinelelst ele 110 81 ri M Expansion Rack 107 00 123 31 110 81 Note The modules can have lever connectors for the new modules or screw connectors Part Number Code Identification 300 107 200 000 P7C MRK AC main rack 300 107 200 010 P7C MRK DC main rack 300 107 200 100 P7C XRK expansion rack 1 Check the Notes and Acronysms List at the beggining of this document Technical Specifications Ref PMU107001 Version 1 0 07 Release 10 20 10 37
7. tions Version 1 0 07 Release 10 20 10 31 User Manual P7C Controller ae i HI tecnologia gt Industrial Applicable Standards P7C controller was developed for attending CE certification requirements being adherent to the standards defined by IEC61131 2 According to the criterion defined by IEC61131 2 the equipment is able to operate on the named Zone B attending to the specification of the following standards Standards Name CISPR11 CISPR16 1 CISPR11 CISPR16 1 and CISPR16 2 IEC61000 4 2 IEC61000 4 3 IEC61000 4 4 IEC61000 4 5 IEC61000 4 6 IEC61000 4 8 Irradiated interference Conducted interference Electromagnetic discharge immunity Irradiated eletromagnetic fields immunity Fast transients immunity Immunity against high energy outbreaks Immunity against conducted radiofrequency Immunity against electromagnetic fields Technical Data Main Rack AC 300 107 200 000 Power Supply AC PWS800 Consumption Operating temperature Storage temperature Humidity Rack weight Box Protection Degree Dimensions 85 to 265 VAC or 100 to 400 VDC automatic 25 Watts m x 0 to 60 C 25 C to 80 C lt 90 without condensation 1 0 Kg approximately Aluminium and Carbon Steel IP30 150 W x 110 H x 115 L mm Technical Data Main Rack DC 300 107 200 010 Power Supply DC DCC850 Consumption Operating temperature Storage temperature Humidity Rack weight Box Protection De