Home
        FX100
         Contents
1.   switched on off  for each channel    Burnout upscale downscale selectable  Burnout condition   Normal  less than 2 kQ  Burnout  more than 100 kQ  Filter function   FX103  On off selectable for each channel  Time constant  selectable from 2  5  and10  seconds  FX106  FX112  Moving average on off selectable for  each channel  moving average cycles 2 to  16 selectable  Calculation  Differential computation  linear scaling   square root    Display  Display unit  5 5 inch TFT color LCD  320 x 240 pixels   Waveform span rate   FX103  15  30 sec   1  2 5  10  15  20  30 min   1  2   4  10 hours div selectable  FX106  FX112   1  2 5  10  15  20  30 min   1  2  4  10  hours div selectable  LCD back light saver function   Automatically dims if no key is touched for a  certain preset time  Timer setpoint   1  2  5  10  30 or 60 min  Temperature unit     C or   F selectable  Language  English  French and German selectable    Data Saving Function    Internal memory   Flash memory  1 2M   External storage medium   Selectable from  1  None  2  3 5 inch floppy disk   2HD  1 44 MB   3  Compact flash memory card   32 to 512 MB   Saving method  Manual or automatic selectable  Measurement data files   Display data and event data  Data saving period   Display data file   Linked with the waveform span rate  Event file  Linked with the specified sampling period  Event File sampling period   FX103  Selectable from 250  500 ms  and 1  2  5   10  30  60  120  300  600 s  FX106  FX112   Selectable fr
2.  and all key  operations are not permitted       User name        User ID    and    password    are  required to enter the operation mode    And key lock by password can be set to  prevent to change settings     GS 04L20A01 00E 1st Edition Oct 10 2003 00     lt  lt Contents gt  gt   lt  lt Index gt  gt        E SPECIFICATIONS OF OPTIONAL  FUNCTIONS    Alarm Output Relays   A1   A2   A3      Outputs  Number of outputs  2  4  6 points  An alarm signal is output from the rear panel as a relay  contact signal   Relay contact rating   250 VDC 0 1 A  for resistance load  250  VAC  50 60 Hz  3 A  Terminal configuration   SPDT  NO C NC   Energized at alarm   deenergized at alarm  AND OR  and hold   non hold actions are selectable     Serial Communication Interface   C2   C3      Allows the host computer to control and make settings  for the recorder as well as receive data from the  recorder   Connection  EIA RS 232   C2  or RS 422 A 485   C3   Protocols  YOKOGAWA private protocol  Modbus  protocol  Synchronization method   Start stop asynchronous transmission  Connection method  RS 422 A 485    4 wire half duplex multi drop connection   1  N where N   1 to 32   Transmission speed   1200  2400  4800  9600  19200 or 38400    bps  Data length  7 or 8 bits  Stop bit  1 bit  Parity  Odd  even  or none  Communication distance  RS 422 A 485    Up to 1 2 km    Communication mode   ASCII for input output for control and setting  ASCII or binary for output of measured data  Modbus communicati
3.  lt  lt Contents gt  gt   lt  lt Index gt  gt     General FX100  Specifications          GS 04L20A01 00E          E OVERVIEW    FX100 displays real time measurement data on TFT color  LCD and saves the data in external media  3 5    FD or  Flash memory card  or FTP server  It comes with a  three  six or twelve channel  As the input signal  a DC  voltage  thermocouple  resistance temperature detector   or contact signal can be set to each channel     NKOLNOLETAWANK 2    GROUP 1 Zy espeennin 216   Sep Bd  2083 15 00 49 RTE                   E Standard Specifications    Construction  Dimensions  144 W  x 144 H  x 234 D  mm      S  Weight  FX1xx   0  2 2 kg Z deer e A A      am      a  mis  C      FX1xx 1  2 5 kg salina   L  FX1xx   4  2 3 kg   Front panel  Water and dust proof  based on IEC529   IP65        Inputs Input Ranges and Measuring Ranges    Number of inputs  Input Type   Input Range Measuring Range  FX103  3 channels  20 00 to 20 00 mV  FX106  6 channels Perey    FX112  12 channels  Measurement interval  200 mV    200 0 to 200 0 mV   2 000 to 2 000 V    FX103  250 ms Pav    6v      6 000 to 6 000 V    FX106  FX112 1s 2s  Inputs  VDC  DC voltage   TC  thermocouple   RTD eer arse   50 00 to 50 00 V    DCV 2V  6V   resistance temperature detector   DI  digital  0 0 to 1760 0  C   32 to 3200 0  F  0 0 to 1760 0  C   32 to 3200 0  F  0 0 to 1820 0  C   32 to 3308 0  F   200 0 to 1370 0  C    328 to 2498 0  F   200 0 to 800 0  C   328 0 to 1472 0  F   200 0 to 1100 0  C   32
4.  of isolated input type    N2 can be specified only for FX106 and FX112   A  B  b legs of FX103 is isolated as standard     Pt1000 input   N3      Measuring ranges  measurement accuracy  and  resolution of digital display   See table of Input and standard performance     Pulse input mathematic function   PM1   Number of inputs   3 points  8 points are available in case of  using remote inputs   Max  sampling pulse period   Max 100 Hz  Minimum pulse length   5 ms  Allowed input voltage   30 VDC  Pulse measuring accuracy    1pulse  for instantaneous mode   Measuring mode   Instantaneous mode setting   Pulse count during measuring period  Summation mode setting   Pulse count summation by mathematical  function  TLOG SUM     Remote Control   R1      Number of remote inputs  8 points   This option allows the following eight functions to be   controlled remotely by a contact input    e Start stop of memory  level    e Trigger for event file  trigger  250 ms or longer    e Time adjustment  adjusting the time to a preset time  upon contact signal  trigger  250 ms or longer    e Start stop of computation  level    e Reset of computation data  trigger  250 ms or longer    e Manual data sample  trigger  250 ms or longer    e Message display  Up to 8 different messages can be  set  trigger  250 ms or longer    e Load of setting parameters   Up to 3 settings can be  set  trigger  and 250 ms or longer except for non   media model    e Alarm acknowledgement  trigger  250 ms or longer    e S
5. 8 0 to 2012 0  F  1a  200 0 to 400 0  C    328 0 to 752 0  F     4     4   Option  6    input for event recording   DCA  DC current   with external shunt resistor attached   0 0 to 1300 0  C 32 to 2372 0  F  0 0 to 2315 0  C     328 0 to 4199 0  F       200 0 to 900 0  C   328 0 to 1652 0  F     200 0 to 400 0  C      328 0 to 752 0  F  0 0 to 2400 0  C 32 to 4352 0  F     200 0 to 600 0  C   328 0 to 1112 0  F  RTD  5  200 0 to 550 0  C   328 0 to 1022 0  F    200 0 to 600 0  C   328 0 to 1112 0  F   OFF  Less than 2 4 V  ON  More than 2 4 V  oo Contact Input ON OFF     1  R  S  B  K  E  J  T  N  IEC584 1 1995   DIN IEC584  JIS C1602 1995   2  W  W   5  Re W 26  Re  Hoskins Mfg  Co    ASTM E988   3  L  Fe CuNi  DIN43710  U  Cu CuNi  DIN43710   4  Pt100  JIS C1604 1997  IEC751 1995  DIN IEC751 1996   JPt100  JIS C1604 1989  JIS C1606 1989   Measuring current  i 1 mA   B  WRe  W 5  Re W 25  Re  Hoskins Mfg  Co     6  Measuring current  i 0 16 mA          GS 04L20A01 00E  YOKOGAWA   Copyright Oct  2003    1st Edition Oct   2003     lt  lt Contents gt  gt   lt  lt Index gt  gt        Inputs terminal  Clamp terminals  clamp connector    detachable terminal connector  Allowable wire size  0 2 to 2 5 mm2  AWG24 12   Integral time of A D converter   20 ms  50 Hz   16 7 ms  60 Hz   100 ms   50 60 Hz  for FX106 and FX112   AUTO selectable  automatic selection by  detection of power supply frequency from  20 ms  16 7 ms   Themoccouple Burnout   Burnout upscale downscale function can be
6. andard Performance    Measuring and Recording Accuracy   The following specifications apply to operation of the recorder under standard operation conditions   Temperature  23 2  C  Humidity   55   10  RH  Power supply voltage   90 to 132 or 180 to 250 VAC   Power supply frequency   50 60 Hz  1   Warm up time   At least 30 min   Other ambient conditions such as vibration should not adversely affect recorder operation     Input Type Measurement accuracy  digital display  Erea       0 1  of rdg   2digits     10 mV     0 1  of rdg   3digits  10 mV    DC voltage   DCV     20 V       ON    BV  EEI        0 15  of rdg   1  C     S   However  R  S   3 7  C at 0 to 100  C    1 5  C at 100 to 300  C  B   2  C at 400 to 600  C   Accuracy at less than 400  C is not guaranteed    Thermocouple   0 15  of rdg   0 7  C    TC   Excluding the However    0 15  of rdg   1  C  at  200 to    100  C  reference junction   0 15  of rdg   0 5  C   compensation owever  0 1  C  accuracy   0 15  of rdg   0 7  C  at  200 to  100  C      0 15  ofrdg 0 7  C  ssi aD      0 15  of rdg   1  00  ssi    0 15  of rdg   0  50   te rons   0 15  of og   0 7  C  at  200 to  100  C  Wae    Pt1000     0 2  of rdg   0 4  C    option     All Rights Reserved  Copyright    2003  Yokogawa Electric Corporation GS 04L20A01 00E 1st Edition Oct 10 2003 00     lt  lt Contents gt  gt   lt  lt Index gt  gt        Measurement accuracy in case of scaling  digits      measurement accuracy  digits   lt  scaling  span  digits  measurem
7. ent span  digits    2  digits  Decimals are rounded off to the next highest number   Reference junction compensation   INT  internal  EXT  external  selectable   common for all channels   Reference junction compensation accuracy   above 0  C  in balance of input terminal  temperature  more than 60 minutes after  application of power    Types R  S  B  W  WRe   1 0  C  Types K  J  E  T  N  L  U   0 5  C  Note  Internal reference junction compensation accuracy  for type B is fixed to 0   C    Maximum allowable input voltage    10 VDC  continuous  for less than  200mVDC ranges and TC  RTD  DI ranges   60 VDC  continuous  for except above  ranges  Input resistance   Approximately 10 MQ or more for DCV  ranges of 200 mVDC or less and TC  Approximately 1 MQ for more than 2 VDC  ranges  Input source resistance   VDC  TC  2 kQ or less  RTD  10    or less per wire  The resistance  of all three wires must be equal    RTD parallel capacity   0 01 uF or less  Input bias current   10 nA or less  Maximum common mode noise voltage   250 VAC rms  50 60 Hz   Maximum noise voltage between channels   250 VAC rms  50 60 Hz   Interference between channels   120 dB  the input source resistance  500 Q  the inputs to other channels  30 V   Common mode rejection ratio   120 dB  50 60 Hz   0 1   500 Q imbalance  between the minus terminal and ground   Normal mode rejection ratio   40 dB  50 60 Hz   0 1      Effects on Operating Conditions    Ambient temperature  With temperature variation of 10  C    F
8. ints 4 o  a T     A2 Alarm output 4 points  1    A3 Alarm output 6 points  1  RS 232 communication interface  including Modbus master slave protocol function   2 3  RS 422 A 485 communication interface  including Modbus master slave protocol function   2 3  ic7   Ethernet  10BASE T  communication interface      FAIL memory end output  4  Mathematical function  with report function      N2 3 legs isolated RTD    Pt1000Q input     PM1 Pulse input 3 points  control input 5 points  including Mathematical function    5  Remote control 8 points     1  A1   A2   A3 cannot be specified together     2  C2   C3 cannot be specified together     3  In case that Modbus master function is utilized   M1 or  PM1 must be specified    4  If  F1 is specified   A3 cannot be specified     5  If  PM1 is specified  each  A3   R1   M1 cannot be specified     5  If  PM1 is specified   A2 and  F1 cannot be specified together        E Application Software E Optional Accessories    Model code  Description   OS   Product  Shunt resister  Clamp module   E Standard Accessories    B9968NM 32 MB    Product   Quantity    Mounting brackets       Mounting bracket B9900BX     1  For a model with no communication port and no external  memory  DAQSTANDARD is not attatched    2  Only for FX1xx 4 model       All Rights Reserved  Copyright    2003  Yokogawa Electric Corporation GS 04L20A01 00E 1st Edition Oct 10 2003 00     lt  lt Contents gt  gt   lt  lt Index gt  gt        E Dimensions                      Unit   m
9. lay output in occurrence of system  alarm   Manual save mode   Relay output before the specified time of  overwriting inside memory  Selectable from 1  2  5  10  20  50  or 100  hours   Auto save mode   Relay output when the amount of memory  media reaches 90    Relay contact rating   250 VDC 0 1 A  for resistance load  250  VAC  50 60 Hz  3 A    Mathematical Functions   M1      Displays and records computed data assigned to  channels  Number of computed data assignable channels   Up to 12 channels  Type of computation   General arithmetic operations   Four arithmetic operations  square root   absolute  common logarithm  exponential   power  relational operations   lt   S   gt   2          logic operations  AND  OR  NOT  XOR   Statistical operations   Average  maximum  minimum and  summation  Long tern rolling average computation   is performed on the results of computation  Constant  Available  Up to 30 constants   Digital data input via communication   Digital data via communication can be used  in mathematical expression  Up to 12 data   Remote status input   Remote input status  0 1  can be used in  mathematical expression  Up to 8 inputs   Report functions   Report type  Hourly  daily  hourly   daily   daily   weekly and daily   monthly  Type of computation   Average  maximum  minimum and  summation  Data format  ASCII    GS 04L20A01 00E 1st Edition Oct 10 2003 00     lt  lt Contents gt  gt   lt  lt Index gt  gt        3 legs Isolated RTD Input   N2      A  B  b legs are
10. m   approx  inch                                    0 95   2 30     24 1 175  6 89  58 4 9 4  0 37   pie       min  space for mounting                                                         7 5  0 30    dimension after mounting        La         RS 232 or RS 422A 485       Ethernet    Power Supply  Terminal       Option Terminal             Input Terminal  1 to 12ch                         All Rights Reserved  Copyright    2003  Yokogawa Electric Corporation    The TCP IP software used in this product and the document for that TCP IP software are based in part on  BSD networking software  Release 1 licensed from The Regents of the University of California     e Microsoft  MS and Windows are registered trademarks of Microsoft Corporation USA   e Lotus and 1 2 3 are registered trademark of Lotus Development Corporation    e Ethernet is a registered trademark of XEROX Corporation    e Modbus is a registered trademark of AEG Schneider    e Other company and or product names are registered trade mark of their manufactures     GS 04L20A01 00E       1st Edition Oct 10 2003 00    
11. napshot  trigger  250 ms or longer        Load of setting parameters is not be available for non   media model     All Rights Reserved  Copyright    2003  Yokogawa Electric Corporation    E APPLICATION SOFTWARE  DAQSTANDARD    Operating environment  OS  Microsoft Windows 98 Me NT4 0 2000 XP  Basic function  packages    Configuration software   External memory medium  configuration of  setup and set mode  Configuration via communication   configuration of setup and set mode without  communication configuration  ex  address   Data viewer   Numbers of display channels   32 channels for each group  at most 30  groups  Display function   Waveform display  digital display  circular  display  list display  TLOG display  report  display etc   File connection display   Connect data files that are divided by auto   save during measuring data or power failure   can connect up to total a million   Section computation   Max  value  Min  value  average value   effective value  p p value  Data conversion   File conversion to ASCII  Lotus 1 2 3 or MS   Excel format  Print out  Print out retrieved data    GS 04L20A01 00E 1st Edition Oct 10 2003 00     lt  lt Contents gt  gt   lt  lt Index gt  gt  T       E Model Code    Model   Suttix code  Optioncode  Description  eos   o    oen oo  exo    doen oo  en   o    oaae ooo  External memory    0      None o  a    frp sine 4am  o          Compactnash memory card 82MB    Display Language    2     English  GermaniFrench  oo  Option im _ Alarmoutput2po
12. om 1  2  5  10  30  60  120   300  and 600 s    All Rights Reserved  Copyright    2003  Yokogawa Electric Corporation    Alarm Function    Number of alarm levels   Up to four levels for each channel  Alarm types High and low limits  differential high and low  limits  high and low rate of change limits  and delay high and low  Interval time of rate of change alarms   The measurement interval times 1 to 15  The alarm status  type  is displayed in the  digital value display area upon occurrence  of an alarm  A common alarm indication is  also displayed   The alarming behavior   Non hold or hold type can be selectable for  common to all channels   Hysteresis  On  0 5  of display span   off selectable   common to all channels and alarm levels   Outputs  Number of points  2  4  or 6 points  optional   Relay action Energized deenergized and hold non hold  selectable   The times of alarm occurrences recoveries   alarm types  etc  are stored in the memory    Up to 120 latest alarm events are stored      Display     Memory     Normal Operating Conditions    Ambient temperature    0 to 50  C  when using FDD  0 to 40  C   Ambient humidity    20  to 80  RH  at 0 to 40  C    10  to 50   RH  at 40 to 50  C   Vibration  10 to 60 Hz  0 2 m s  or less  Shock  Not acceptable  Magnetic field  400 AT m or less  DC and 50 60 Hz   Noise    Normal mode  50 60 Hz     VDC  The peak value including the signal must  be less than 1 2 times the measuring  range    TC  The peak value including the signal m
13. on   Operation mode  RTU MASTER or RTU SLAVE    Ethernet Communication   C7     Connection  Ethernet  10BASE T   Protocols  SMTP  HTTP1 0  FTP  TCP  UDP  IP  ARP   ICMP  E mail inform function   Kinds of inform   The following information can be informed  by E mail  selectable from inform misinform  for each group  Alarm inform   Informs in occurring alarm canceling alarm  System inform   Informs in recovering power failure informs  the time of recovering  informs the rest of  time before rewriting on Inside memory   manual save mode  informs the rest of  amount in reaching 90  of media volume  and media error  auto save mode   Schedule time inform  Inform the moment value at a  certain time or interval  Report inform  Inform report data in report timeup    All Rights Reserved  Copyright    2003  Yokogawa Electric Corporation    Web server function   Displays an image  alarm information  and  moment values of FX screen by browser  soft   Enables message input from browser  screen    FTP client function   File auto transfer from FX  display data file   event file  report file  and snapshot    FTP server function   Manual transfer of file in the outside media  from host computer  directory operation   information of file elimination and of rest of  amount of memory in media   Real time monitoring function   Real time monitoring FX data by  communication  Yokogawa private protocol     Fail Memory End Output   F1      The relay contact output in following cases   System Error  Re
14. or VDC and TC range     0 1  of rdg   1 digit  or less  For RTD inputs     0 1  of rdg   2 digits  or less   Power supply  With variation within 90 to 132 V and 180  to 250 VAC  50 60 Hz     1 digit or less  With variation of  2 Hz from rated power  frequency  at 100 VAC     0 1  of rdg   1  digit  or less   Magnetic field  AC  50 60 Hz  and DC 400 A m fields     0 1  of rdg   10 digits  or less    All Rights Reserved  Copyright    2003  Yokogawa Electric Corporation    Input source resistance  With variation of  1 KQ   1  VDC range   Ranges of 200 mV or less  within  10 uV  Ranges of 2 V or greater   approximately  0 1  of rdg   2  TC range  Within  10 uV    100 uV when the  burnout upscale downscale function is  switched on    3  RTD range  Pt100    With variation of 10 Q per wire  resistance  of all three wires must be equal     0 1  of  rdg   1 digit   With maximum difference of 40 mQ between wires   Approximately 0 1  C    Other Specifications    Clock  With calendar function  year of grace   The time can be adjusted by a remote  contact  with the remote option     Summer winter time    Summer and wintertime can be set    Accuracy of clock    100 ppm  excluding a delay  of 1 second   maximum  caused each time the power is  turned on    Memory backup    A built in lithium battery backs up the setup  parameters  battery life  approximately ten  years at room temperature     Key lock function    ON OFF and password can be set    Log in function    Power on with log out mode
15. ust  be less than 1 2 times the measuring  thermal electromotive force    RTD  100 mV or less   Common mode noise voltage  50 60 Hz    250 V AC rms or less for all ranges  Maximum noise voltage between channels  50 60 Hz    250 V AC rms or less  Warm up time  At least 30 min after power on    Transport and Storage Conditions    Ambient temperature      25  C to 60  C  Humidity  5  to 95  RH  No condensation is  allowed   Vibration  10 to 60 Hz  4 9 m s  maximum  Shock  392 m s  maximum  while being packed   Safety and EMC Standards  Safety standards   CSA22 2 No 1010 1  UL61010B B  CSA  NRTL C   EN61010 1  EMC standard   EN61326  EN55011 Class A  EN61000 3 2  EN61000 3 3    GS 04L20A01 00E 1st Edition Oct 10 2003 00     lt  lt Contents gt  gt   lt  lt Index gt  gt  3       Power Supply Dielectric strength     Power supply to ground terminal   Rated power supply  l  ee a Contact Aa ate EAE  Allowable power supply voltage range  i  90 to 132 or 180 to 264 VAC ee  OODD ee ENIN    Measuring input terminal to ground terminal   1500 VAC  50 60 Hz   1 min  Between measuring input terminals   1000 VAC  50 60 Hz   1 min  except for b    LOD eave mods   Normal     Max    terminal of RTD input of non isolated   Pp   y g Between remote control terminal to ground terminal   1000 VDC  1 min  1000 VDC  1 min  Insulation resistance     Each terminal to ground terminal   20 MV or greater  at 500 VDC     Rated power supply frequency   50 60 Hz  automatic switching   Power consumption        St
    