Home

Sinewave Inverters

image

Contents

1. Peak Power 250VA 65 C ON 45 C OFF Output Waveform Pure Sinewave Isolation Input Output 1100VDC Input Case 1100VDC Protection Short circuit Overload pur ans ee eircuitry Overtemperature Indicators Overload Overtemperature Length 20 0 cm Height 7 2 cm Clearance 2 5 cm all around Nominal voltage VDC 12 24 Material Aluminium Voltage range VDC 10 5 15 21 30 Finish Black Anodize Powder Epoxy Coat Amps Pnom A 14 6 5 Weight 2 7 Kg Protection circuitry Overvoltage Lowvoltage 12V DC Car Plug 24V DC cable Idle current 230V ON A 0 22 0 17 Connections AC connector Efficiency max 91 93 Connector supplied with inverter Efficiency full load 72 80 Warranty 2 years Indicators Overvoltage Lowvoltage Standards Approval to CE e Mark 300VA Nominal VAC 230 5 Operating Temp 10 to 40 C maximum output Output Frequency 50Hz 0 3 Range Derating Linearly 4 per C from 40 C Nominal power 300VA continous Humidity 0 95 Relative Humidity non condensing Nominal current 1 3A 230VAC nominal Power Audible Noise NONE Odb 1m Fan OFF Power for 3 min 360VA Fan Load and temperature controlled Peak Power 500VA 65 C ON 45 C OFF Output Waveform Pure Sinewave Isolation Input Output 1100VDC Input Case 1100VDC Protection Short circuit Overload Output Case 500VDC circuitry Overtemperature Indicators Overload Overtemperat
2. a short notice about your system and the failure observed In case you have to send the unit above state borders please make sure to fill the correct pa pers needed for customs To reduce time and save money contact the consignee how to de clare the delivery Arising costs for customs has to be paid by the sender An actual list of authorized service center will be provided at our homepage www ripenergy ch Manual Swing doc 11 12 Version 1 1 21 Notes Manual Swing doc 12 12 Version 1 1
3. fast red Cut Off caused by DC Over voltage Flashing slow red sssssssssssseseeeeneen enne Cut Off caused by DC Low voltage Steady red erinnerte Cut Off caused by overload Flashing intermittently red see Cut Off caused by over temperature 17 Maintenance Only little maintenance is required to keep your inverter and system operating reliable The inverter must be switched off during maintenance and or repair activities It also must be secured against un expected and unintentional switching on Therefore switch off the connection between batteries and inverter and be sure that third parties cannot reverse the measures taken The following Steps must be undertaken at least once a year Check cable and wires for damage and if they are still firmly connected Defects such as loose connections ore damaged cables etc must be corrected immediately Keep the inverter dry clean it from dust in order to ensure good heat dis charge Manual Swing doc 9 12 Version 1 1 18 Technical data 150VA Nominal VAC 230 5 Operating Temp 10 to 40 C maximum output Output Frequency 50Hz 0 3 Range Derating Linearly 4 per C from 40 C Nominal power 150VA continous Humidity 0 95 Relative Humidity non condensing Nominal current 0 65A 230VAC nominal Power Audible Noise NONE Odb 1m Fan OFF Power for 3 min 200VA Load and temperature controlled
4. of the inverter Even more safe is to use a 15mA or 30mA earth leakage switch in the AC Installation 13 5 Grounding The earth wire protection is only possible if the inverter enclosure is also connected to earth Use a 8 10mm2 cable AWG 8 and connect it to the earth terminal of the inverter This is also important for lighting protection 14 Remote ON OFF Use a cable 0 75mm2 and standard switch for remote controlled ON OFF of the Inverter Connect the cable to the provided remote terminals on the inverter The main switch on the front panel of the inverter must be in the remote position when using the remote switch to control the inverter Manual Swing doc 8 12 Version 1 1 15 Operation The Inverter is controlled by a single three position switch located on the front panel of the inverter Engaging Switch to ON Position The green LED will illuminate The Inverter is ready to use Power down Switch to OFF Position All LED s are dark The inverter is OFF Remark Even if the inverter is switched to off it is not disconnected from the battery It still draws very little power from the battery If you don t need the inverter for an extended period disconnect it from the battery to avoid low discharge of battery Before using the remote cable to control the inverter the main switch must be in the REMOTE Position 16 LED Display Steady Green Anne teda te epi tee d De Peres ebbe eei AC Output OK Flashing
5. or breaking the warranty label without a written permission from RIPEnergy AG means that the warranty is lost immediately Always return the units in it s original package and completely assembled A short description of the failure problem will help us to serve you better see also instructions on item 20 RIPEnergy AG is not paying for costs arising for transport of the unit or damage that arise during the time the unit is unserviceable The general terms of delivery and terms of sale of RIPEnergy AG are valid 8 Unpacking After unpacking carefully check the inverter for possible damage If any damage due to transport is visible immediately contact your dealer for further instructions Keep the original packing in case you need it to transport the inverter later 9 Environmental protection RIPEnergy AG continually commits a considerable part of its resources towards minimizing the envi ronmental impact of its products The inverter is manufactured with valuable materials and easy to recycle 10 Description of the inverter The model Swing 150VA and Swing 300VA pure sinewave inverter supplies a 230VAC output voltage either from a 12V or 24V VDC power source The shape of the output voltage is pure sinewave clean power as from the grid The inverter design is based on proven 50Hz technologie All functions are controlled by a micropro cessor Extra input and output filtering to reduce EMI to extremely low levels Reliability featur
6. Sinewave Inverters SWING 150VA and 300VA User s manual Sw pue Sinewa 1 Warranty RIPEnergy is not manufacturer of these units All technical information s data s and dimension s rely on information s given by the manufacturer Therefore RIPEnergy AG is not responsible for the data s provided in this manual Should work take place which is not in accordance with guidelines local rules instruction s or specification s damage may occur All of these matters will lead to loss of war ranty RIPEnergy AG can not accept any liability for damages or costs arising due to the use of these inverters 2 Distributor s address RIPEne The power conversion company RIPEnergy AG W gitalstrasse 24 CH 8854 Siebnen Schweiz Tel 41 0 43 8185385 Fax 41 0 43 818 53 87 Email info ripenergy ch Internet www RIPEnergy ch 3 Retail dealer s address Date of purchase Manual Swing doc 2 12 Version 1 1 Contents OONOOARWND 13 lur 2 Distributors address cree teat e o s eto tese ta etae un een ee tecta redd 2 Retail dealers address Date of purchase ssssssssssseeeneeenn nennen 2 General Informatlon rte rete pte cete e Dice ae pn oe ive Pete eoe vaa 4 Use ofthis mantalean eet et t etta estre neto ebene real 4 Limitation ot lrabllity 3 ertet ee tete tae ect et Ri ta e thee e de tete bete aus 4 Warranty specifications short form ssssssesseseeeenenen nennen nne 4 Bere de TE e
7. ater If acid contacts eyes immediately flush with running cold water for at least 20 minutes and get medical attention as soon as possible Never smoke or allow a spark or flame in vicinity of batteries Do not drop metal tools on batteries The resulting spark or short circuit may cause an explosion Remove personal metal items such as rings bracelets necklaces and watches when working with batteries 13 Planning and mounting the inverter This section will provide you information s about configuring and installing your inverter Make sure that you are aware of local rules and safety measurements 13 1 Required power draw Before connecting your appliances to the inverter always check the power draw required The inverter is affordable to supply surge power for a short time so as to start up electrical equipment such as pumps motors etc Some equipment needs more power while starting up The inverter is protected against overload and will switch off automatically when overload is applied As ambient temperature is above 20 C the inverters nominal power may be smaller due to reduced cooling Using the inverter in high altitudes may also reduce nominal power of the inverter because of less heat discharge As a rule of thumb the reduction of nominal power is approximately 1 596 per 100m eleva tion 13 2 Installation These units must be only installed by qualified authorized and trained personnel familiar with the locally applicab
8. e 5 Environmental protection arrarir aan iann RAAKA ARESE TATARAN AAAA AAA AAS RAR IAPAA SARANKAN 5 Description of the inverter orpoen naa arana Aena AARET CARENE ERARON VA AERE AAAA AAR AVAATA nennt nennen 5 Block 9 Te zio MET 6 Safety Information iet Reinheit 6 12 1 General informatlon ias Are rein linke 6 12 2 Working with batteries 444444444HHnnnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn enne 7 Planning and mounting the inverter nennen nennen nennen 7 13 1 Required power draw erarintan rairai idaan TAES RAN HATARA TEA EER a AATAS AANE ARANEA TEREGA AER FAREA 7 13 2 AAEE E m A EE EEE T EEE AE TNE TEE A A TE E T 7 13 3 Beute ER 8 19 4 AB WirNg sio rer Len e E EL LH EU et 8 13 5 GFOUNdINGE ts dac emt cA ct Lett se Acc eM E ee 8 Remote ON ORE Ze kes Here re e eL LER c E MD LE a 8 SBeratign sodes dec Mtt e M cc E M Ce R d 9 EED DISplay ein detenti ntetetediteat dta LLL t aattet 9 Maintenance i detta ti cree dese tede tere e eL eec teeter errs 9 Technical data s aestate adeundi nte 10 Trouble shooting En teste bee Dalee poe tbe ee bb e an ad 11 Further assistance and sending the unit for repair sseeen e 11 INOteS itt ta pee teme t aD etes DAL Lt Ld E i 12 Manual Swing doc 3 12 Version 1 1 4 General Information Thank you for choosing a product supplied by RIPEnergy AG The product you have bought is manu factured to meet the highest quality standards Our manufactu
9. e is above 2 55V Cell Remove the battery charger and stop charging the battery Note If battery voltage is dropping below 2 5V Cell the inverter restarts auto matically If load is smaller than nominal power of inverter check if ventilation of the inverter is blocked Maybe the ambient temperature is too high Over temperature If load is exceeding nominal power of inverter reduce the load Note The inverter will switch on automatically if temperature of the inverter is within normal operating temperature range Overload Reduce load Remove unnecessary consumers Reset the inverter with the front panel switch OFF than ON Other failures Check system for correct grounding or contact your dealer V Cell The nominal voltage using lead acid batteries is 2VDC Cell Example A 12V Battery contains 6 single cells a 24V Battery contains 12 single cells etc 20 Further assistance and sending the unit for repair In the rare case the unit is not working contact your dealer providing him some details as 1 2 3 Check Battery voltage wiring and display for possible failures Note Type of unit and serial number Now call your dealer or nearest service center They will help you with further instruction s If he is recommend to send the unit for repair use the original packing Include a copy of invoice Warranty repair is only possible with a copy of invoice or certificate showing date of purchase and
10. es in clude an input fuse thermal shutdown current limiting and output short circuit shutdown with automat ic recovery The input and output is fully isolated The superb overload capability supplies short time peak power to start heavy equipment such as pumps and compressors Manual Swing doc 5 12 Version 1 1 11 Block Diagram Power Board UL Internal Power Microprozessor Supply Board Remote Display Unit Input Output L DC Source Battery Fuel Cell Wind PV Power supply etc DC Filtering AC Filtering AC Consumers TV PC Fridge Light Pumps etc 12 Safety Information 12 1 General information Read the manual carefully before installing or operating the inverter If you do not understand or are uncertain about any operation or information please contact your dealer Before installation you must be aware of local standards and rules applicable to use such equipment For installation and use of the inverter pay attention to local applicable standards all relevant safety guidelines and measures These rules may be different to the information s provided in this manual High voltages up to 1200V inside the inverter Never open the enclosure High voltage may harm or even kill persons or animals Never touch wires or blank connectors Do not operate the inverter with damaged or substandard wiring Check local standards for lightning protection of inverter systems No other inverter out
11. le standards and taking into consideration all relevant safety guidelines and measures Before installing the unit check for correct DC Voltage and power level of the inverter The Inverter may be installed in any position Install the inverter in a dry well ventilated and dust free location It must be installed out of reach for unauthorized personnel especially children s Do not in stall the inverter in the same compartment as the batteries Never use or install the inverter in locations where there is gas or explosive danger For proper cooling of the Inverter ensure that the airflow is not obstructed and keep a clearance dis tance of 2 5cm to other units If the inverter is installed in a closed compartment the nominal power may be reduced In order to keep the battery cables as short as possible max 6m locate the inverter close to the DC Distribution or Battery Be aware that during charging of batteries an explosive gas can be generated Manual Swing doc 7 12 Version 1 1 13 3 DC Wiring Position of the switch on the front panel must be OFF A high power fuse must be installed direct to the battery to protect the DC Wiring not for Swing 150 12 230 DC current according to the datasheet Not installing a fuse may result in melting or even burning DC Cables in case of excessive overload or failure of the inverter The way of wiring has influence on the EMC behaviour of the system Most problems using inverter are because of
12. ny loss damage or costs arising from operating these inverters The products supplied by RIPEnergy AG are not for application s in any medical equipment intended for use as a component of any life support system If products are used in such systems a specific written agreement between the manufacturer RIPEnergy AG and the installer manufacturer of the System is needed In addition the manufacturer of the system must agree to indemnify RIPEnergy AG from any claims arising from use of products supplied by RIPEnergy AG in the life support equipment 7 Warranty specifications short form The inverters are built for RIPEnergy AG in according to the legally applicable standards During pro duction and prior to delivery all products are tested and inspected RIPEnergy AG is looking to find the best available products on the market Good quality parts and the latest technology of the units will ensure a long lasting and trouble free operation of these units Manual Swing doc 4 12 Version 1 1 If any problem occurs during warranty period please contact your dealer first He is able to serve you with instructions and explains you how to send the unit to the nearest service center if necessary Warranty can only be guaranteed if you enclose a document Invoice or delivery documents to the defective units Damage attributable to normal wear and tear overload or improper handling or installation is not cov ered by the warranty Modifications
13. put AC Generator or other AC Source may be connected to the inverters AC Output The inverter will be destroyed immediately The enclosure may heat up to 80 C Never obstruct louvers nor place other items on the inverters enclosure If ventilation is not sufficient the unit may overheat and an automatic shut off may occur Even if DC Wiring is not longer connected to the batteries inbuilt large capacitors may hold Dc Voltage for an extended period of time The inverter may only be opened by skilled and authorized personnel Modifications or breaking the warranty label without a written permission from RIPEnergy AG means that warranty is lost immediately The inverter contains components which can produce arks and sparks To prevent fire or explosion do not install or operate in compartments containing batteries or flammable materials Never use or operate the unit where there is danger of gas or dust explosion After automatic shut down of the inverter because of any failure the inverter may switch ON automatic again The OFF period is depending on what causes the shut down and may vary from only seconds to several minutes Manual Swing doc 6 12 Version 1 1 12 2 Working with batteries Using batteries in awrong way may result in danger for personnel animals or the environment Check information from battery manufacturer for safe installation and operation If battery acid contacts skin or clothing wash immediately with soap and w
14. rers have a very long experience in manufacturing of high end electronic equipment 5 Use of this manual This user s manual contains the information you need to install and operate this inverter correctly Check that you have the correct manual for your unit It is valid for the following units Sinewave Inverter Swing 150 12 230 and 150 24 230 Sinewave Inverter Swing 300 12 230 and 300 24 230 Read the manual carefully before installing or operating the inverter If you do not under stand or are uncertain about any operation or information please contact your dealer He will be able to help you with an explanation or will demonstrate the operation These inverters must be only installed by qualified authorized and trained personnel familiar with the locally applicable standards and taking into consideration all relevant safety guidelines and measures Never remove the type number plate Important technical information required for service or delivery of spare parts can be derived from the type number plate The user must always have access to the user s manual The latest version of the manual is provided and can be downloaded from the homepage of RIPEnergy AG AG means that warranty is lost immediately Modifications or breaking the warranty label without a written permission from RIPEnergy Always contact your dealer first if you have any problems 6 Limitation of liability RIPENERGY AG is not responsible or liable for a
15. unprofessional wiring Lay the cables in a metal duct If this is not possible the cables should be twisted and lay parallel to a metal bar To thin cable or loose connections can cause dangerous overheating of cables or terminals Always use DC cables of the correct size to avoid fire and other damage To define the size of cable we provide a Cable Size Calculator on our website for free use Only SWING 150 12 230 DC Connector already mounted to DC Cable Do not remove It is for use with cigarette lighter output in your car Check the fuse of your car for correct size gt 15A Connect the cables with care to the battery inline fuse If possible use coloured cables Red colour means battery positive while black is used for battery negative Reversing positive and negative will cause major damage to the inverter and is not covered by warranty Note Large capacitors in the units may hold DC Voltage for a long period of time Also a spark may occur while connecting the DC cables or inserting the DC Fuse after installation This is normal If you connect other consumers to the battery contact your dealer 13 4 AC Wiring Use the included AC Connector to connect the AC Load to the output of the inverter Even the inverter is protected against overload and short circuit we recommend to use an AC Circuit breaker of correct size For safe operation it is necessary to connect earth PE and neutral N of the inverter output to central ground
16. ure Width 15 5 cm Height 7 2cm Nominal voltage VDC 12 24 Clearance 2 5 cm all around Voltage range VDC 10 5 15 21 30 Material Aluminium Amps Pnom A 27 13 Finish Black Anodize Powder Epoxy Coat Protection circuitry Overvoltage Lowvoltage Weight 3 5Kg Idle current 230V ON A 0 25 0 19 c i DC cable AC connector onnections m Efficiency max 9196 94 Connector supplied with inverter Efficiency full load 72 80 Warranty 2 years Indicators Overvoltage Lowvoltage Standards Approval to CE e Mark Manual Swing doc 10 12 Version 1 1 19 Trouble shooting Warning Never remove the cover of the inverter Do not self repair the inverter no serviceable parts are inside the unit Check LED Display to identify the reason According the failure indicated by the display see sections below to solve the problem No function Check wiring for correct size damage or loose screws Check batteries battery fuse or fuse installed on AC output If switch is in remote position but no remote cable is connected switch it to the ON Position The battery voltage dropped below 1 75V Cell Check battery fuse Charge the battery if charging is not solving the problem maybe the battery is DC Low voltage defect The wiring may be too thin or check installation for loose connections Note If battery voltage rises above 2 1V Cell the inverter restarts automatical ly DC Over voltage The battery voltag

Download Pdf Manuals

image

Related Search

Related Contents

servicios a la navegacion en el espacio aereo mexicano  INSTALLATION AND OPERATION INSTRUCTIONS FOR Liberty US    Simplexa™ CMV - Focus Diagnostics  Manual de instalação  cado de G arantia Certifi  Mikrotik RB493G  preliminary - HDTV Solutions  pimus tipo - Arca Costruzioni  PB21FLf_PU 6,9,12G & PU 6 GX frz:PB02LWT_03 dt Wandhyd gr  