1. DSA 1000 RS232 Cable PRT 1000 1 Attach DSA 1000 to a power source either through adaptors provided in the package or through DC socket with a DC power supply 2 Attach Thermal Printer to a power source through adaptors provided in the package and turn on the power switch situated on the left side of the device 3 Connect Thermal Printer to the COM1 port of DSA 1000 by a RS 232 cable provided within Thermal Printer package 4 Connect DSA 1000 to the LAN port of your Gateway Controller by an Ethernet cable Note You need to connect to the correct LAN port if your Gateway Controller is operating in Port based mode 5 To verify that the system is up and running enter the WMI of your Gateway Controller and ping DSA 1000 192 168 1 10 You should see replies from DSA 1000 as shown below this means that the de vices are setup and working properly 10 Wake on LAN Ping Trace Route ARP Table Status PING 192 168 1 10 192 168 1 10 56 84 bytes of data 64 bytes from 192 168 1 10 icmp_seg 1 t 64 time 1 31 ms 64 bytes from 192 168 1 10 icmp_seq tl 64 time 1 39 ms 64 bytes from 192 168 1 10 icmp_seq 3 ttl 64 time 1 32 ms 64 bytes from 192 168 1 10 icmp_seg 4 tl 64 time 1 34 ms Result 192 168 1 10 ping statistics 4 packets transmitted 4 received 0 packet loss time 3003ms rtt min avg max mdey 1 317 1 346 1 390 0 027 ms lf you are unable to get a reply from pinging DSA 1000 please refer to Sys
2. configured to match your Note serial device operating requirements If your serial device application operates on pure serial communication then you need to setup a COM port redirector _6 2 Device Overview Panel Overview 12V 1A Restart 10 100Mbps Cott Top Panel Mi DSA 1000 com com2 ee Link Act icombps OPTION FUNCTION gt COMI se nein Bottom Panel Main Panel Top Panel Adapter Socket The power socket for connecting to an external power source 12V 1A through the power adapter provided in the package DC Socket DC12V The power socket for connecting to an external power source through a DC power supply Restart Button Press to restart DSA 1000 Ethernet Port Ethernet port for connecting to a Controller Gateway Bottom Panel Serial Port for connection with a Thermal Printer COM 2 Serial Port for connection with a Thermal Printer Used for back up when COM 1 malfunctions Main Panel LED indicators Power Turned on when properly connect to power supply COM 1 Turned on when output is switched to COM1 Note When COM 1 and COM 2 are blinking simultaneously this means that Device Server configuration is not set correctly Please check the settings in Device Server of your Gate way Controller When COM 1 and COM 2 are turned on simultaneously this means that the system is in safe mode COM 2 Turned on when output is switched to COM2 Note W
3. er provided in the package Connect the administrator PC to the Ethernet Port of DSA 1000 via an Ethernet cable Launch a web browser and type in the default IP address of DSA 1000 in the address field http 192 168 1 10 the web interface of DSA 1000 should appear Serial Settings Data Baud Rate 9600 v Data Bits 8 v Data Paritiy None v Stop Bits 1 v Flow Control None v Network Settings Static IP Address 192 168 1 10 Static Subnet Mask 255 255 255 0 Static Default Gateway 192 168 1254 Static DNS Server 168 95 1 1 Transmit Timer 10 Server Listening Port 5000 Lock Password 0 Cl Safe Mode Se Utilities Firmware Upgrade Apply Restart Apply Reset to Factory Default Apply Status Software Version Step3 Change DSA 1000 Network Settings if necessary so that the IP address of DSA 1000 is under the same subnet as the Gateway Controller s interface which DSA 1000 will be connected to Click Apply to save the settings Serial Settings Data Baud Rate 9800 v Data Bits 8 v Data Paritiy None v Stop Bits 1 v Flow Control None v Network Settings Static IP Address 192 168 1 10 Static Subnet Mask 255 255 255 0 Static Default Gateway 192 168 1254 Static DNS Server 168 95 1 1 Transmit Timer 10 Server Listening Port 5000 Lock Password 0 Cl Safe Mode So Utilities Firmware Upgrade Apply Restart Apply R
4. eset to Factory Default Apply Status Software Version 243 2 4 2 Gateway Controller Configuration procedures are similar on all Gateway Controller models the following instruction steps uses WHG 1000 as illustration Note the screenshots may be slightly different for your Gateway Controller model Step1 Connect administrator PC to your Gateway Controller and access the WMI web management interface Sy Sem Uses Betio k Lili ties STALS Welcome to System Main Menu This Administrative Web Interface allows you to set various networking parameters to customize network services to manage iser accounts and to monitor user status Functions are separated into 5 main categories System Users Network Utilities and Status Step2 Enter the configuration page of the Service Zone which DSA 1000 will be connected to Check to make sure that the network settings of DSA 1000 are under the same subnet as this service zone Basic Settings Private Operation Mode NAT Router Network Interface Disable DHCP Server Enable DHCP Server Start IP Address 192 168 1 1 End IP Address 192 168 1 100 Preferred DNS Server 192 168 1 254 DHCP Server Alternate DNS Server Domain Name domain WINS Server Lease Time 1Day v Reserved IP Address List Enable DHCP Relay 14 Step3 Go to the configuration page for On demand authentication click Configure to edit Device Server settings Enter the IP add
5. hen COM 1 and COM 2 are blinking simultaneously this means that Device Server configuration is not set correctly Please check the settings in Device Server of your Gate way Controller When COM 1 and COM 2 are turned on simultaneously this means that the system is in safe mode Link Act Turned on when LAN port is connected to an upstream networking device such as a switch or Gateway Controller 100 Mbps Turned on when LAN port is connected 7 Segment Displays an integer between 0 9 which indicates the billing plan number selected For future use Il OPTION Increase the numeric display for selecting a billing plan number For switching the output to COM1 or COM2 Press this button followed by selecting a number and press Enter will perform a specific action The available combinations are as follows FUNTION 1 ENTER Print out the IP address of DSA 1000 FUNTION 8 ENTER Enter panel test mode FUNTION 9 ENTER Reset DSA 1000 to factory default FUNTION 0 ENTER Lock the panel of DSA 1000 To Unlock select your lock number and press ENTER Decrease the numeric display for selecting a billing plan number Create and print out an account for the chosen billing plan 3 Hardware Setup The following diagram illustrates how to connect DSA 1000 to the Thermal Printer and Gate ways Controllers Please follow the steps described below to install hardware Ethernet Cable WHG 1000
6. led Note ae Appendix A DSA 1000 Web Interface Summary The attribute setting in this web interface is for COM 1 only COM 2 uses default settings that are unchan geable Serial Settings Data Baud Rate Data Bits Data Pariti Stop Bits Flow Control Network Settings Static IP Address 192 168 1 10 Static Subnet Mask 255 255 255 0 Static Default Gateway 192 168 1254 Static DNS Server 1685 95 11 Transmit Timer 0 Server Listening Port Lock Fassword C safe Mode Be Utilities Firmware Upgrade Restart Apply Reset to Factory Default Apply Status Software Version Serial Settings corresponding to Thermal Printer Data Baud Rate Select the desired baud rate The number of characters per second transferred Select the number of bits in each character Data Parity Choose between Even or Odd for error detection or select None for no error detection Stop Bits Choose the number of stop bits to be sent at the end of every character Electronic devices usually use 1 bit slower electromechanical devices use 1 5 bit Flow Control Choose the method of flow control to pause and resume the transmission of data to coordinate with printer speed Select None if flow control is not required Appendix E Command Line Interface Transmit Timer TCP transmit timer set the desired value or use default value When the timer expires for a sent packet sender will retransmit the packet Server Listening Po
7. level Eanes E Ki Zea E DE B one LevelOne DSA 1000 PRT 1000 Device Server Thermal Printer User Manual TABLE OF CONTENTS MMI ROD UG PIO INicsasceisisacaccacccosanseareonsaseanaasscanscesuoucsseedaseedersausoudescustoupsonasveasecensenscuansecseabacenssntesaedutsusesdonasaucsuaareens E 3 2 DEVICE OVERVIEW spsiscissicsssssassaucsascesacsessssecsssecosssussasonsasnsbasseseotesnsssosdevsce sssevectensonsavoasopeesouatucessosesencesendsouesoacsecenseveaeesaeredseos 7 HARDWARE SETUP esana E 10 4 SYSTEM CONFIGURATION All trademarks and trade names are the properties of their respective owners 1 Introduction Overview of Ticket Generator Kit Whether you are operating a wireless hotspot service for generating revenue or providing free but controlled wireless internet access to guests it would be handy to both the operators and the wireless users if the account information Such as username password SSID and etc can be readily output to Thermal Printers and printed out as account tickets DSA 1000 is designed specifically to operate in conjunction with specific Controllers Gateways Typical serial Thermal Printers on the market today may or may not be IP network ready and it is not practical to integrate each brand one by one with Controllers Gateways Hence it has specifically designed a smart device server DSA 1000 for two purposes 1 Attaching before a serial Thermal Printer so that o
8. ne or more Thermal Printers can be connected to a Controller Gateway via IP networks 2 Pre integrated with the Controller Gateway so that account generation becomes quick and easy to the operator simply by a push of buttons on the device It provides DSA 1000 and a Thermal Printer as a combo set called Ticket Generator Kit The followings are typical application scenarios A small business who wishes to quickly set up a wireless service hotspot for charged internet service may purchase a Gateway and a Ticket Generator Kits set The Gateway alone serves as an AP and a gateway Ticket Generator Kit enables the registration operator to generate and issue accounts via push buttons on the DSA 1000 and hand out the account ticket printed out by Thermal Printer Acorporate has several sites Deployed at the reception area of each site are with a DSA 1000 and a Thermal Printer Guests who need wireless connection to the internet simply need to request the receptionist and obtain a slip with account information The guest account will automatically expire after the pre configured time A hotel has a Controller Gateway and multiple APs within it s hospitality areas Multiple sets of Ticket Generator Kit are distributed at the service desks and lounge counters The service clerks are able to create accounts for their guests with charged or free internet service depending on the hotel s service model Below are two network diagrams examples usi
9. ng Ticket Generator Kit combo set 1 One Gateway with one Ticket Generator Kit set WHG 1000 DSA 1000 RS232 Cable PRT 1000 2 One Gateway with multiple Ticket Generator Kit sets Ethernet Cable DSA 1000 Bi 232 Coble DSA 1000 RS232 Cable PRT 1000 PRT 1000 Application Diagram Ethernet Cable R45 g fE R5232 Authentication Server RADIUS LOAF Authenticate users POPS 500 on demand accounts XDSLCable Modem Internet _ Monitor and Configure 20 IP m devices of status WHG 1000 a AAA Admin 10 Billing pians LANI private LAN2 Regired authentication Trusted users DSA 1000 DSA 1000 k Oevjee Server IP devices IP device Manage up to 10sets j of printer ji PRT 1000 _ ll PRT 1000 Authenticate users Therrmial Thermal Printer Printer Though DSA 1000 is specifically designed to for on demand account generation and operate Thermal Printers it can also be deployed independently to connect other RS232 devices to an Ethernet network for remote operation If you will be deploying DSA 1000 independently to manage other serial devices please carefully set the Serial Settings in DSA 1000 to match the operating needs of your serial device If you connect other serial device to DSA 1000 and are unable to remotely operate your connected serial device please check that The settings under Serial Settings of DSA 1000 are
10. ress 192 168 1 10 and Port 5000 of DSA 1000 Ticket Customization Configure Billing Plans Configure External Payment Gateway Configure Terminal Server Configure On demand Account Creation Create Ye Terminal Server Configuration Item Server IP Port Location Remark 192 168 1 10 5000 ae Step4 Edit and enable desired billing plans Billing Plans Plan Type Quota Price Enable Function 1 Usage time 10 day s 2 hr s 3 min s 34 7 Edit 2 Duration time From 2010 05 20 01 18 00 till 2010 06 25 07 15 00 45 W Edit 3 Usage time 8 day s 9 hr s 30 min s 5 W Edit 4 N A Edit 5 N A Edit 6 N A Edit ee 5 Operation Instructions After completing the Hardware Setup and the devices are physically connected the system is ready for operation This section will describe how to operate DSA 1000 to printout tickets for enabled billing plans 1 Select an enabled billing plan number on DSA 1000 ORD button The numeric LED dis play on the center of the device represents the billing plan number currently selected Press button on DSA 1000 to create and print out an on demand account of the selected billing plan THERMAL PRINTER will print out the ticket with the text format Without background image con figured on your Gateway Controller in Ticket Customization If you are unable to get a ticket printout after pressing ENTER please check if the selected plan is enab
11. rt set the port number for communication with the Gate way Controller Lock Password This attribute is the integer between 0 9 that will be set as the password for unlocking the main panel Firmware Upgrade Firmware of DSA 1000 can be upgraded by clicking the Apply button Note Upgrade preparations are required before upgrade please refer to Appendix B Firmware Upgrade Restart Click Apply to restart DSA 1000 device Reset to Factory Default Click Apply to reset DSA 1000 to factory default settings Software Version The current software version running on DSA 1000 18 Appendix E Command Line Interface Appendix B Firmware Upgrade Software tools tftpd32 is required in the upgrade procedure please download and install tftod32 before you proceed further Tftpd32 can be downloaded from the following link Note iittp tftpd32 jounin net tftpd32 html Step1 Place the new firmware of DSA 1000 on a local location for example desktop in the PC that is accessing DSA 1000 s web interface and performing the upgrade Step2 Configure the TCP IP settings of your PC with an IP address under the same subnet mask as DSA 1000 For example 192 168 1 20 Step3 Launch tftpd32 and click the DHCP tab 1 In Current Directory field browse for the location path where the firmware is stored 2 Enter the IP address of your PC in Server interfaces field 3 In P pool starting address field enter the start IP addre
12. ss of an IP segment that is available for allocation 4 Set the size of the IP pool 5 Enter the firmware filename in Boot file field 6 Enter 255 255 0 0 in the Mask field 7 Click Save button Note Please make sure that the location path and the firmware for upgrade is correct 19 Appendix E Command Line Interface 1 Current Directory Le AUsershuser Desktor 3 IF pool starting address Size of pool Boot File WINS ONS Server Default router Mask Domain Name Additional Option Settings Step4 Click Apply of Firmware Upgrade in DSA 1000 s web interface DSA 1000 will automatically res tart and connect to tftpd32 server set in Step3 as a DHCP client download the firmware and perform the upgrade Progress can be observed on tftpd32 gt Tftpd32 by Ph Jounin Current Directory C Users user Desktop _ Browse Server interlace 192 166 1 20 show Dir Titp Server Tftp Client DHCP server Syslog server Log viewer IF pool starting address 1921681 3 _ Size of pool E r Boot File p100 00 00200 bin WINS DNS Server D000 _ Default router Dani o Mask 255 255 00 Domain Hame p 4ipnet_SDS100 1_00_00 00200 Teea File size 149633 00 06 10 10 35 94208 Bytes sent 11776 Butes sec Step5 When complete check the information displayed at Software Version DSA 1000 have successful ly upgraded to the new firmware 20
13. tem Configuration Note and check that the network settings of DSA 1000 and Gateway Controller interface connected to are under the same subnet 11 4 System Configuration DSA 1000 is designed specifically to operate in conjunction with all Gateways Controllers If you are not using default settings before connecting DSA 1000 to your Gateway Controller some configurations steps are required The configuration instructions for Gateways Controllers and DSA 1000 are covered in the following sections 4 1 DSA 1000 DSA 1000 supports web based configuration By factory default DSA 1000 web interface can be ac cessed with IP address 192 168 1 10 Subnet Mask 255 255 255 0 Default Gateway 192 168 1 254 Step1 Configure administrator PC s TCP IP settings with a static IP address that is under the same subnet mask as DSA 1000 For example 192 168 1 20 Internet Protocol TCP IP Properties See ee General Tou can get IF settings assigned automatically if your network supports this capability Otherwise pou need to ask your network administrator for the appropriate IP settings O Obtain an IF address automatically Use the following IP address IP address 168 1 20 Subnet mask 255 255 255 0 Default gateway 2 168 1 254 Use the following DNS server addresses Preferred ONS server Alternate ONS server ae Step2 Attach DSA 1000 to a power supply using the adapt

Download Pdf Manuals

image

Related Search

Related Contents

METRISO PRIME+ Comprobador de aislamiento de alta tensión digital  Département - Ecole Nationale de la Magistrature  Targus Bluetooth Multimedia Keypad  CatLog-S2 - User Manual  L220x Breitbildmonitor Bedienungsanleitung  TOTO  Bosch KIR18V20GB refrigerator  Location liste de prix  Guía de inicio rápido  Philips myKidsRoom Suspension light 40279/55/16  