Home
WX201 DataBrowser User`s Manual
Contents
1. Note If Search Subfolders is Selected e Searches the subfiles within the specified folder e All data files 1 to 9 are searched Specified search folder 1 2 4 5 6 7 8 9 The maximum allowable length for a path is 255 characters including the file name IM WX201 01E 2 4 Executing the Search Procedure Explanation IM WX201 01E 1 Specify search folders and search conditions See sections 2 2 and 2 3 2 Click the Search button in the Search conditions area Select the Search subfolders check box if necessary Ji Search subfolders Search Search within results The Search status dialog box appears Search status Host Name Folder ID Status Status Error 1 CPCO01 13666 01 Folder001 Finished 295 401 OH 2 CPCO01 13666 01 Folder002 Finished FFE OH 3 CPCO01 13666 01 FolderD03 Finished 36 37 OH d CPCO01 13666 01 Folder004 Finished 0 29 OH 5 cPco01 05713 02 Folder BO02 Failure 070 Ka E4946 Connection failure Changes to the Close button when the serach stop When searching ei JJ Host Name Displays the name ofthe host containing the specified search folder Folder ID Displays the folder ID of the specified search folder Status left Displays the search status Starting Searching Receiving data in progress Yo Finished Error An error occured during the search Stop Press to stop the search Status right Displa
2. Explanation The Import Data files function allows you to copy data files saved on the floppy disk or CF card of a recorder to a specified folder By specifying a copy source and destination the first time you import files subsequent imports can be done quickly and easily Note Only folders on the local host can be specified as the source and destination folders Select Buttons Import Data files Dialog Box A folder for specifying folders is displayed New Folder Browse Folders Dialog Box Lets you create a new folder in a specified location The Create New Folder dialog box is displayed Start Button Import Data files Dialog Box Executes the import of data files This button is not active unless a source and destination folder are selected Stop Button Import Data files Dialog Box Becomes available once importing has started Stops the importing of data files Close Button Import Data files Dialog Box Closes the Import Data files dialog box OK Button Create New Folder Dialog Box Creates the new folder Cancel Button Create New Folder Dialog Box Cancels creation of the new folder and closes the Browse Folders dialog box 2 24 IM WX201 01E Chapter 3 3 1 Operation of the Trend Display Window Names of Parts in the Trend Display Window The Trend display window consists of the display channel settings screen and the waveform display screen Opening the Trend Display Window Procedure 1 Click cas
3. Output Fie CC DataBrowserbinengiProject output votpat xla File Faso Esc 3 Select a conversion type of Excel Text or Lotus To change the range of data to be converted specify a Start and End point 4 Enter the number of steps See Explanation for details 5 To select a channel whose interval is to be used for the interval during data conversion select the Write Measured point of the following channel check box and click the Select button The Selection dialog box opens See Explanation for details Select the channel for output of measured points 6 If you click channel whose measured points are output that channel is displayed in the Data Conversion dialog box 7 Click the File button The File name dialog box opens AAA WW AR Savein E Output EI rb PS Save as hype Excel Files xls sl Cancel YA IM WX201 01E 3 23 MOPUIM Aeldsig pudij au jo uougiodo H 3 8 Converting Data Formats 8 Enter a destination folder and file name and click the OK button The name of the output file appears in the Data Conversion dialog box 9 Click the Start button eg Data Conversion EA Start 450 2004412403 15 36 46 000 End Gi 20044 2 05 15 44 22 000 Step Setting IM Write Measured point of the following channel OH CHO Select Output File DA WDataBrowseribinteng Projectioutputiutput xls File a Start Close
4. Explanation Conversion Type Excel Data that can be opened using Microsoft s spreadsheet application Excel version 8 0 Excel97 or later The extension is xls Text Text data with each data point separated by a comma The extension is DN Lotus Data that can be opened using Lotus spreadsheet application 1 2 3 version 2 0 or later The extension is wj2 Start and End Points You can select a range of data to convert If cursors are placed in the trend display screen the range determined by the cursors defines the start and end points If no cursors are displayed all the first and last data of all the data represent the start and end points Also the start and end times are displayed to the right of the entry boxes Step Setting You can specify an interval for data conversion output This area includes the setting for the number of steps and a setting for specifying the channel whose measured points are to be output Write Measured point of the following channel e If the Write Measured point of the following channel check box is not selected the measured points of all channels assigned to the group are output and the smallest unit interval is used as the reference interval e If the Write Measured point of the following channel check box is selected the interval of the selected channel is used as the reference interval e By specifying the number of steps rather than outputting all points in the range steps 1 you ca
5. Wd pp CHO2 Min Max 20044 2 08 14 05 10 000 20044 2108 14 12 46 000 ee display Value of Cursor A Value of Cursor B A Value of Cursor B Time of Cursor A Time of Cursor B Alarm indication Explanation The data at the currently displayed cursors are displayed Data No Displays the data number at the Cursor A and B positions Time Difference Displays the time difference between cursors A and B Relative Time Displays the time using the first data of the displayed range between cursors A and B as a reference Value A and Value B Displays the values and alarms of each channel at cursor A or cursor B Changes to red if an alarm occurred and green if an alarm did not occur The value is blank if no data exists at the cursor position Value B A Displays the result of subtracting the values at cursor A from those at cursor B Time A and Time B Displays the time at cursors A and B IM WX201 01E 3 17 MOPUIM Aeldsig pudij au Jo uougiodo H 3 5 Displaying Cursor Values Normal and MinMax Format Display Values of channels In Normal format are displayed in a single row Values of channels in MinMax format are displayed in two rows one for the minimum and maximum value at the cursor position Switching the Active Channel You can switch the active channel The active channel mark is displayed between the waveform number and its color Click the box of the channel you wish to make active This changes
6. a E E ATAN Bee _ UE Seen EI See For Help click Help Topics on the Help Menu A IM WX201 01E 3 5 Displaying Cursor Values 1 Inthe waveform display click the group from which you wish to read values using Cursors 2 Click the position in the waveform display area where you wish to read the data If you wish to read another point at the same time drag the cursor Cursor A appears at the position where you first clicked Cursor B appears at the position where you released the mouse button The measurement point is displayed where the waveform and the cursor cross using a yellow circle Cursor B Cursor A 3 Click the Display Cursor Rearout button on the toolbar The Cursor Readout dialog box opens Data number at the Cursor A position Move Data number at the Cursor B position Cursor A Move Cursor B E S Difference in the data Active channel mark Cursor js Cursor E Difference number between Data No Cursor A and B Time Difference Relative Time 000 15 00 000 000 22 36 Channel HOM Min Max HOI Min Max HOM Min Max Time A 20041 2 03 15 36 46 000 20044 2 03 15 36 46 000 20041 2 03 15 36 46 000 2004 14 2 03 15 36 46 000 200441 2 08 14 05 10 000 20044 2 08 14 05 10 000 20044 2 08 14 05 10 000 Time B 2004 1 2103 15 44 22 000 2004 1 2103 15 44 22 000 2004 1 2 03 15 44 22 000 2004 1 2 03 15 44 22 000 20044 206 14 12 46 000 2004 206 14 12 46 000 2004 206 14 12 46 000
7. s DataBrowser Trend display New config VS File View Window Help ll x 18 x Ba cas AM 2 kuiunga a Group Name Group01 Pi Scale Zone Fom No Channel Y Axis om Min SE Se Trip1 Trip 2 Color la WW TAGOOO1 m Linear 4 200 0 200 0 0 mr 200 0 r 200 0 B fl VYO2 TAC0002 Lo Linear 4 60 00 60 00 0 100 F 60 00 60 00 fa WWO3 TAGO003 Lo Linear 4 2 000 2 000 0 100 r 2 000 2 000 fl VYO4 TAGOOO4 La Linear 4 200 0 200 0 0 100 F 200 0 7 200 0 fa wos 00001 Lei Linear 4 2 0000 2 0000 0 100 2 0000 2 0000 fi woe 00002 La Linear 4 2 0000 2 0000 0 100 F 2 0000 2 0000 fa WO 00003 Lo Linear 4 2 0000 2 0000 0 100 2 0000 2 0000 fa wog 00004 Lo Linear 4 2 0000 2 0000 0 100 r 2 0000 2 0000 B G B D H H H B M G M M LFL e e KR Le J IM WX201 01E 3 1 Names of Parts in the Trend Display Window Explanation Group Name You can specify a group name using up to thirty alohanumeric characters No Number assigned within groups Channel Tag Number and Tag Comment Displays identifiers for the channels display can be switched using the group tab tool bar Start Time Time of the first data End Time Time of the last data Trigger Time Time of the trigger point if no trigger point exists the first data is used Interval sec The save interval for the data Data Size The number of saved data Data Type The instrument or software that saved the dat
8. Reacquires channel data Copy Opens the trend display screens Opens the channel setup screens RAR E hl MM Me Zei i L Shows channel details Displays conversion settings Displays computed results statistcs Displays the cursor values Clip Scale calculation Switches between absolute time Relative time Zoom in and out display all specify factor Switches the trend display User zone Edit zone Full zone Side zone Auto zone Multi zone 3 4 IM WX201 01E 3 2 Selecting a Group for Adding Channels Channels can be assigned to groups in the channel display configure screen Up to fifty groups can be created each with up to thirty two channels When channels are added in the Search window see section 2 6 they are added to the selected groups Adding and Deleting Groups Clicking the ES button in either of the channel setup screens adds a new group tab on the end of any existing tabs Clicking the button in either of the channel setup screens deletes the currently displayed group tab Linked Group Settings IM WX201 01E This function links cursor positions and time reference modes across groups in the trend display screen The available settings are Link OFF Link 1 Link 2 3 and 4 You can select either from any group Groups with the same link number are called inked groups and up to four linked groups can be set Select a group then select one of the options OFF i E 7 J AA OP oo r
9. AddTrigger Yes No Note Instruments that can save in MinMax format such as the DX100 200 MV100 200 CX1000 2000 and FX100 save data in two formats called Event data and Display data format Event data is saved in Normal format and Display data is saved in MinMax format For details see the user s manual for your particular instrument 3 12 IM WX201 01E 3 4 Displaying Trends Waveform Display in Normal Format indstop and indstart MinMax Format In Normal format waveforms are displayed in the position corresponding to the data value at that time In MinMax format waveforms are displayed as a fill between the two points corresponding to the Min and Max values at that time When the Min and Max values are the same items are displayed as if in Normal format If the difference between the Min and Max values is large the thickness of the trace increases Intersection between Waveform and Cursor In Normal format the intersection is marked with a circle In MinMax format the two intersecting points of the Min and Max values are enclosed by an ellipse Normal Format MinMax Format Circle Ellips Maximum value Minmum value Displaying Alarms You can show or hide the alarm display area using the Alarm ON OFF button on the toolbar This operation mirrors the alarm ON OFF operation in the Cursor Value dialog box Up to four alarm levels per channel are allowed As shown in the figure below the alarm levels are 1 2 3 and 4 starting
10. The Host List displays the names of any hosts on the network that are running DataBrowser Up to two hundred hosts can be displayed File List Displays the settings files and comments saved on the host selected in the host list Host Name Displays the name of the host selected in the host list Update button Updates the host list and file list Open Button and Cancel Button See Opening Search Results Files from a Local Host 2 22 IM WX201 01E 2 8 Copying Data Files This section describes the procedure for copying a data file from a specified folder to another folder Procedure 1 Click mp on the toolbar or choose File gt Import Data Files from the menu bar The Import Data files dialog box opens Import Data files Source Select Destination Select start Cancel 2 Click the Select button for the Source The Browse for Folders dialog box is displayed Browse for roder E Ar 040 WOR AME Ce ata Floppy AN EH DAQWORS Bey ddr oof AddObserver Runtime oof AddQbserver Sr AddTrigger DAQ32Plus O DAQ32Plus Client of DAQEXPLORER oof DAQLOGGER f DAQLOGGER Client gt New Folder Cancel 3 Select a source folder and click the OK button The Import Data files dialog box reappears 4 Asin step 2 click the Select button for the Destination The Browse for Folders dialog box is displayed Dil hiranoiDACWwORe Trend Data C D
11. date and time Time Range or for those of a specific time range regardless of the day Time Range each day 2 File Name Search for data files of a specified file name or extension 3 Data Type Search for data files from a specific instrument DX100 200 CX1000 2000 MX100 MV100 200 or FX100 or data acquisition software application DAQLOGGER AddTrigger or AddMulti MKLOGGER MX Standard 4 Keywords Search for data files containing a specified keyword s 5 Serial Number Search for data files of the specified instrument serial number Data Display Function Trend Display Window e You can display waveforms of data having different times and acquisition intervals and obtained by different instruments and applications all on the same screen e You can read values using cursors and compute statistics over an area e Data can be converted to Excel text or Lotus format e All data or a range of data specified by the cursor can be printed Diagram of Data Saving and Loading Seach settings files Search results files Search results files IM WX201 01E 1 1 Jasmoige eg ou Buisn a10jog E 1 1 Overview of DataBrowser Diagram of Data Searching and Display conditions 24 Send Ke Date time range conditions each day Mapanga File name Each host must be running D
12. 22 Copying Data FIGS Wi 2 23 Contents vi Chapter 3 Operation of the Trend Display Window Chapter 4 Index 3 1 Names of Parts in the Trend Display Window n nennnnnsnnnnnsnnennsrrrnesrrrnssrrrnsrrrrrsrnrresrrrrennne 3 1 Opening the Trend Display Window nnnnnnnsnnnnonnnnnnnnnennnssnsnnnnnnnnnnnsrsrnnrrrrrrensnssnnnrnrrrrernnene 3 1 Display Channel Setting Screen cc ccccccsesccccecceeeeesseeeeeeeeeeeceeeeeeseeeeeeeeceeeeeesssssaeasseeeeeeees 3 1 Editing Functions in the Channel Display Configure Green 3 3 Waveform Display Screen ccccccccccceeececeeeeseeeeeeceeeeeseeaeesseeceeeeeesseesauaseceeeeeeeeessaeaaaaeesess 3 4 3 2 Selecting a Group for Adding Channels 3 5 Adding and Deleting Ee wrcaccictesexssccatececcaduveediesendascddocertncieimceucnenceddindendiierdecendelotenentes 3 5 Linked Group E dl EN 3 5 3 3 Settings in the Channel Setup Screens snsn000nannnnennennnennnnnnnnnnnnsesrnnnnrnrrnnnnsennnrnrrrennenene 3 6 SA DISH Lee EE 3 9 Displaying Waveforms of Different Intervals cccccseccecceseeeeecesseeecceeeeeseueeeseeaeseesseees 3 11 Time Reference Mode nonnennnnnennnnnnnensrnnnrrnsrrnrnrrssrnrrrrnsrnrrrrrnnrrrrrnnrsnnrrrnnnnnnrernnnnrrrrn nnn 3 12 Save Format of Displayed Data 3 12 Display NGA MS ai 3 13 MPS RE 3 13 Ee AG HO E 3 15 EIER Eege 3 16 Copying the Trend RRE 3 16 35 Displaying Curso aati U2 III 3 17 WA dere 3 18 3 6 Displaying Comp
13. 3 5 6 and 11 shall survive any termination of this Agreement 11 Governing Law Disputes This Agreement shall be governed by and construed in accordance with the laws of Japan Any dispute controversies or differences which may arise between the parties hereto out of in relation to or in connection with this Agreement Dispute shall be resolved amicably through negotiation between the parties based on mutual trust Should the parties fail to settle the Dispute within ninety 90 days after the notice is given from either party to the other the Dispute shall be addressed in the following manner i If you are a Japanese individual or entity the Dispute shall be brought exclusively in the Tokyo District Court The Main Court in Japan ii If you are not a Japanese individual or entity the Dispute shall be finally settled by arbitration in Tokyo Japan in accordance with the Commercial Arbitration Rules of the Japan Commercial Arbitration Association All proceedings in arbitration shall be conducted in the English language unless otherwise agreed The award of arbitration shall be final and binding upon both parties however each party may make an application to any court having jurisdiction for judgment to be entered on the award and or for enforcement of the award 12 Miscellaneous 12 1 This Agreement supersedes all prior oral and written understandings representations and discussions between the parties concerning the subject matter
14. EXCEED THE DEPRECIATED VALUE OF THE LICENSE FEE PAID TO YOKOGAWA FOR THE USE OF THE CONCERNED PART OF THE SOFTWARE PRODUCT If the Software Product delivered by Yokogawa is altered modified or combined with other software or is otherwise made different from Yokogawa catalogues General Specifications basic specifications functional specifications or manuals without Yokogawa s prior written consent Yokogawa shall be exempted from its obligations and liabilities under this Agreement or law 6 2 Any claim against Yokogawa based on any cause of action under or in relation to this Agreement must be given in writing to Yokogawa within three 3 months after the cause of action accrues 7 Export Control You agree not to export or provide to any other countries whether directly or indirectly the Software Product in whole or in part without prior written consent of Yokogawa If Yokogawa agrees such exportation or provision you shall comply with the export control and related laws regulations and orders of Japan the United States of America and any other applicable countries and obtain export import permit and take all necessary procedures under your own responsibility and at your own expense 8 Audit Withholding 8 1 Yokogawa shall have the right to access and audit your facilities and any of your records including data stored on computers in relation to the use of the Software Product as may be reasonably necessary in Yokogawa s opinion to verif
15. PP Shows the difference between the maximum and minimum values of the range selected by the cursors or the entire range Mean Shows the mean values of the range selected by the cursors or the entire range RMS Shows the RMS values of the range selected by the cursors or the entire range Start Time and End Time Shows the start and end times for computation for each channel Progress Bar Displays the execution status of the computation Calculate button Recalculates the statistics If you change the positions of cursors while the Statistics dialog box is open click this button to refresh the computed results Note e The cursors used to display cursor values and those used to specify the interval for statistical computation over an area are the same e The Statistics dialog box and Cursor Value dialog box can be displayed at the same time e The statistical results are not linked to cursor movements or switching of groups After any such changes are made click the Statistics button or the Calculate button to recalculate and display the results 3 19 MOPUIM Aeldsig pu L au jo uougiodo H 3 Saving and Loading Trend Settings Saving Data Trend Settings Procedure Explanation 3 20 1 Click KR the Save button in the DataBrowser window or choose File gt Save current trend configuration as from the menu bar The Save the trend settings dialog box appears imi xil ba cave the trend settings u Delet
16. Software License Agreement li OVERVIEW of This Manual EIA iv Chapter 1 Before Using the DataBrowser Chapter 2 IM WX201 01E 1 1 1 2 1 3 1 4 Overview BEE Ee 1 1 W I ele ia Re e 1 1 Diagram of Data Saving and LOading wwwww wmmmmmmwmwwmanannmaawanuwunanzanananw wima na namana 1 1 Diagram of Data Searching and Duepl y 1 2 Communication with Network HoOSts ccccccccesssssesseeceeeeeeeceseeeeeeeeeeeeeeeeseeaeeeseeeeeeeeeeeaeaaas 1 2 SYSTEM Requirements ccccccccccsseseeeeeecceeeeeeesaeaeeeseeeeeeeeeeeseueeesseeeeeeeessesaeaasaaeeeeeeeeessesaaaagas 1 3 Starting and Exiting the Software cccccccccccseeeeeeeeceeeeeeeeeeeaeeeeseeeeeeeeessaeaeeaeeeeeeeeeesesaeaas 1 4 Staring bier 1 4 Exiting the WA AAA 1 4 Fow OC ON cae scsine eeresnse pce aeceuebene 1 5 Operation of the Data Search Window 2 1 2 2 2 3 24 2 5 2 6 ZA 2 8 Names of Parts in the Data Search Window snsnn0nnannnnnnnnnnennnnnnnnnnnnnsnsnnnrnnnnrnnsnsnnnrrnrenen 2 1 Registering and Specifying Search Folders cccccecccccssseeeeceecsesseeeeeeeseeeeeeeessaeaeeseeeeeeas 2 2 Registering New Search Folders cccccssseeccecceeececseeeeeeeecceceeeseeseaeeeseeceeeeeesssesaaasseeeeeeeeess 2 2 Specifying a Folder from the ist 2 3 Registering a Folder from the Explorer 2 4 Notes When Registering Search Folders cccccssseecccecceesseeceeeeceeseeeeeseeaeaeeeeesseeaeeeeeese
17. day for any day 5 Enter a range of dates and time by year month date and time or a daily time range Date and time specification allows you to search for files containing data acquired on certain dates and times Milliseconds cannot be specified here and any milliseconds in files are read as 0 by the program The files included by the date and time specification range are shown in the figure below Given date times A and B the search finds any files containing data between A and B As long as the file contains data between A and B it is found even if it also contains data prior to A Likewise it is found if the start date time is between A and B Files 1 2 and 3 are found but not file 4 A B 13 00 00 15 00 00 2 00 00 0 13 00 50 faaooo to 170000 T aaa ay IM WX201 01E 2 3 Specifying Search Conditions Specifying a File Name or Extension Procedure 1 Specify a search folder See section 2 2 2 Select the File Name check box in the Search conditions area 3 Click the File Name tab or click the words File Name to the right of the check box The File Name tab is displayed Check box Search conditions i Time FileName Data Type Keywords Serial No Time KAN File Name v File Name mb RE EH DAGLOGGER E Data Type L 1 Extension keywords 3 Serial No MOPUIM y2129S Veq eu JO uoneiado bel Search subfolders Search Search
18. from the top level The colors of channels on which alarms occurred indicate the period of occurrence If multiple alarms occur at the same time the alarm of the active channel is displayed in front MOPUIM Aeldsig pudij au jo uougiodo H Alarm level 1 Alarm level 2 Alarm level 3 Alarm level 4 Y Axis Display There are six formats for the Y axis user zone edit zone full zone slide zone auto zone and multi zone You can switch between them using the toolbar User Zone The waveform of each channel is displayed in the position specified under Zone in the channel display configure screen A single Y axis of the active waveform is displayed Active Y axis mark Displays the Y axis of the active channel Click a Y axis of the active channel IM WX201 01E 3 13 3 4 Displaying Trends Edit Zone The waveform of each channel is displayed in the position specified under Zone in the Channel Display Configuration Screen You can edit the waveform display range by manipulating the Y axis buttons in the zone display area Move the waveform position by dragging the Y axis button up and down The waveform zone settings implemented here are reflected in the Zone setting in the Channel display configuration screen as well as the user zone and multi zone settings A single Y axis of the active waveform is displayed Active Y axis mar Displays the Y axis of Drag the knob to the active channel change the minimum maximum valu
19. hereof to the extent such understandings representations and discussions should be discrepant or inconsistent with this Agreement 12 2 If any part of this Agreement is found void or unenforceable it shall not affect the validity of the balance of the Agreement which shall remain valid and enforceable according to its terms and conditions The parties hereby agree to attempt to substitute for such invalid or unenforceable provision a valid or enforceable provision that achieves to the greatest extent possible the economic legal and commercial objectives of the invalid or unenforceable provision 12 3 Failure by either party to insist on performance of this Agreement or to exercise a right when entitled does not prevent such party from doing so at a later time either in relation to that default or any subsequent one End of document IM WX201 01E iii Overview of This Manual Structure of This Manual This manual consists of four chapters and an index as shown below Chapter Title 1 Before Using the DataBrowser 2 Operation of the Data Serarch Window 3 Operation of the Trend Display Window 4 Responding to Error Messages Index Scope of This Manual This manual does not explain the basic operations of your PC s operating system OS For information regarding the basic operations of Windows see the Windows user s manual Conventions Used in This Manual Unit K Denotes 1024 Example 100 KB M Denotes 1024 K Example 10
20. instrument or PC software Data Types DAQLOGGER AddMulti AddTrigger MX100 data file created on the MX100 or with the MXLOGGER software or the MX100 standard software DX100 DX200 MV100 MV200 and CX1000 CX2000 FX100 Specifying Keywords Procedure 1 Specify a search folder See section 2 2 2 Select the Keyword check bor in the Search conditions area 3 Click the Keywords tab or click the word Keywords to the right of the check bor The Keywords tab is displayed Check box Search conditions e S Time File Name Data Type Keywords Serial No O Time Keywords Yokogawa C File Name Search key fail Data Type Comment KE Batch Information BINO SWAI s Tag Comment Bi Tag No viikeywords m IJI Channel E Group Name E Serial No E Mark Message Search subfolders Search Search within results Click to the right of each item to change the tabs on the right d Select a search key then enter a keyword or keywords to search for 2 8 IM WX201 01E 2 3 Specifying Search Conditions Explanation Keyword specification allows you to search for files that contain the keywords in their text or data Files that do not contain any data of the specified search key are not included in the search The table below shows the types of data available by product Bagger Adamuiti AddTrigger MX100 Dx100 200 mV100 200 Cx100072000 FX100_ Filecomments ww PT n a a v data type exists in
21. not removed from the Folder List Likewise even if you delete a folder from the Folder List it is not removed from the Search paths area A new folder cannot be registered under the same folder ID as one that is currently registered in the Search paths area Likewise a new folder cannot be registered under the same folder ID as one that is currently registered in the Folder List area However the same folder can be registered twice under a different folder ID 2 5 MOPUIM y2129S Veq 24 JO uoneiado 2 3 Specifying Search Conditions The following five categories of search criteria can be used Multiple search conditions can be specified Date and or time range File name or extension Data type Keywords Serial numbers Specifying a Date and or Time Range 2 6 Procedure Explanation 1 Specify a search folder See section 2 2 2 Select the Time check box in the Search conditions area 3 Click the Time tab or click the word Time to the right of the check box The Time tab is displayed Check box Search conditions 8 EE Time File Name Data Type Keywords Serial No V Time a gt l Time Range Bis C 2005 2 3 uu Toate type 2008 23 Gottes B Keywords Time Range each day CE E E Serial No Search subfolders Search i Search within results Click to the right of each item to change the tabs on the right 4 Select Time Range for a specific day or Time Range each
22. on the toolbar or choose File gt Open from the menu bar The Open dialog box is displayed Click the Hosts on network tab The Hosts on network tab is displayed Click the Update button The names of hosts running DataBrowser and their corresponding files names and comments are displayed JD x Open Local Host Hosts on network Host List oo Update button Host Mame 1 CPCOO1 05713 02 Double click a number to open the file Drag to change the column width Host Mame CPCO01 057135 02 File Name Comment fy 1 ei C1000 BOU db ZGeachzettnob Feb 03 2005 l 2 il DAGLOGGER_BO01 db SeachSettingB_Feb 03 2005 F File Type Search settings tilet dbo gt Goen neet Select a host from the Host List The a list of files saved on the selected host is displayed Select a file from the list that you wish to load and click Open or double click the file number The Information dialog box opens Information 2 y 1 M451 Replace the current search settings with the selected settings Click the Yes button The search paths and search conditions loaded from the search settings file are displayed Click No to close the Information dialog box Host List The Host List displays the names of any hosts on the network that are running DataBrowser Up to two hundred hosts can be displayed File List Displays the settings files and comments saved on the host se
23. on the toolbar or choose View gt Trend display from the menu bar The Trend display window opens Display Channel Setting Screen The display channel setting screen can display the channel information screen or the channel display configure screen each of which contain channels added from the search results Channel Information Screen Display Channel Setting Screen Toolbar Display Channel Setting Screen groups toolbar Menu bar Toolbar MOPUIM Aejdsig pudijl y jo uonedo WA Eile View Window Help l81 x le m GH ze S 2 Mi maen T h A sf A o Group Name Group01 No Channel Start Time End Time Trigger Time Interval sec WO1 TA amp GOOO1 2000 01 103 14 28 35 000 2000 01 403 14 29 05 000 2000 01 403 14 28 35 000 4 000 WI TAGOOO2 2000 01 03 14 29 35 000 2000 01 403 14 30 05 000 2000 01 403 14 29 35 000 4 000 WU TAGOOO3 2000 01 103 14 30 35 000 2000 01 403 14 31 05 000 2000 01 403 14 30 35 000 4 000 WA TAGOOD4 2000 01 403 14 31 35 000 2000 01 403 14 32 05 000 2000 01 403 14 31 35 000 4 000 wos 00001 2000 01 03 14 26 55 700 2000 01 403 14 28 14 200 2000 01 403 14 27 20 700 0 100 Woe 00002 2000 01 103 14 26 55 700 2000 01 403 14 28 14 200 2000 01 403 14 27 20 700 0 100 Wo 00003 2000 01 103 14 26 55 700 2000 01 403 14 28 14 200 2000 01 403 14 27 20 700 0 100 wos 00004 2000 01 103 14 26 55 700 2000 01 403 14 28 14 200 2000 01 403 14 27 20 700 0 100 Channel Display Configure Screen
24. when complete the waveforms appear click the Cancel button to stop the loading process Only the waveforms of channels completely loaded at the point the Cancel button was clicked are displayed To load the remaining waveforms click the Get data for all channels button Receiveing Host 1 1 CPC001 13666 01 File 2 3 Z0813500 DDS Channel Of 4 CHO2 DRRHRHEIERD Cancel Waveform display p Reacquire channel data button button HHba aeB en SOX HA AARAA O Wi R ml LE SZ Grou aen uu i rip point OR SE Mark display area display area tab Zone size bar Grid color adjusutment slider MOpuIM Aejdsig pues y Jo uougiodo H Cursor A 5S3 Y axis button Y axis display area Active Y axis mark Background adjustment slider 17 3400 TIFT Toe 17 33 45 ZZ UD Absolute Time h m s Zone display fl E area Show hide Zone display bar Time axis display Alarm display Time axis waveform button area area magnification Note If some channels are not displayed check the following e That the host exists and that it is running DataBrowser e That the files shown under File Name in the folder indicated by the path in the Channel Information dialog box exist e That the network is connected correctly and that no problems occurred on the network IM WX201 01E 3 9 3 4 Displaying Trends Explanation Group Selection Tabs Click a tab to display the
25. y Units Comment Intormation Batch Information tem Contejnts Start Time 2000 1901 103 14 25 56 100 End Time 200 101 03 14 30 56 900 Trigger Time 200 101 03 14 25 56 700 Interval Sec 0 100 Data Size 2001 Serial No 12002917 Data Type WAO File Name MAU OtSGER 01 03 1425 mid Path Name LAS YAA Deatabrows sridataiis1 00 Host Mame CPC I01 1 3666 04 Displays the batch informaition page Displays the comment information page Information Tab Displays the start time end time trigger time interval sec data size data type file name path name and host name If the data has no trigger point the first data is used Comment Information Tab Displays the title and tag comment Displays all comments The item is blank if the data contains no comments Batch Information Tab Displays the batch information The items are blank if the data contains no batch information The displayed items are application supervisor manager batch name lot number comment user comment time and comments 1 through 3 for details see the user s manual of the instrument that saved the batch information 3 8 IM WX201 01E 3 4 Displaying Trends Displays waveforms according to the settings in the channel setup screens Procedure 1 Click the Show the trend display button in either of the channel setup screens The channels selected in the tab are loaded While loading the Receiving dialog box is displayed and
26. 00 0 100 2 0000 Li wog 00002 Drag to select a range La Linear 4 2 0000 2 0000 0 400 2 0000 L 00003 La Linear 4 2 0000 2 0000 0 400 2 0000 fa vyo 00004 La Linear 4 2 0000 2 0000 0 400 2 0000 t G H H H G M B M rot II Il 1 E 1 RH 1 z KLS Click to select for Click this button to Click this button to set all Click this button Copying Pasting turn all select buttons tothe same as the topof to reset to default The flaf is display ON OFF collectively the selection Copy Copies the selected range to the clipboard Paste Pastes copied contents to the displayed group If a range is selected pastes the contents into that range If a range is not selected the contents are added at the bottom IM WX201 01E 3 3 MOPUIM Aeldsig pudij au Jo uougiodo H 3 1 Names of Parts in the Trend Display Window Waveform Display Screen Displays the waveforms of the channels in the channel information screen Menu bar Toolbar Waveform Display Screen Toolbar NC Moa s BRAZ 7REGEGH Pes OHARRA O MN i Mme AAE r Groupo1 oam Groups Groups 15 40 00 15 45 00 15 50 00 15 55 00 16 00 00 16 05 00 16 10 00 Absolute Time h m s Ready Waveform Display Screen Toolbar baa eneen AOR HE ax _ Linked group settings Switches the time reference mode OFF 1 2 3 4 Start Trigger End Time Select all Switches between Channel Delete cursors Tag No and Tag Comment Shows hides alarms
27. 0517 TAGOO0S 0006 TAGOOOE 000E TAGO006 OOO TAGOOOT 0007 TAGOOOF 000 TAGOODS 000 TAGOO08 000a ITAGO009 000a TAGOO0S 0010 TAGOON 0 0010 T amp G0010 0011 rap 0011 TAGO01 1 0012 TAGO012 0012 TAG0012 0013 TAGOO1 0013 TA amp G0013 EI EI Note The Add buttons are hidden if the File Details area is scrolled to the right In this case you can double click the item or click the Add channels to this trend configuration button 2 16 IM WX201 01E 2 7 Saving and Loading Search Settings and Results Saving Search Settings Procedure 1 Click DJ on the toolbar or choose File gt Save search settings as from the menu bar The Save search settings dialog box appears fn Save Soo jail _ Delete button Pest Search settings file El a Update button Comment Search conditiions Feb 07 2005 Search conditions Feb 08 2005 Search conditions Feb 07 2005 Search conditions _Feb 07 2005 File Name ce AgcMuEOH dbc EF DAGLOGGERN dbe ef DX100 01 be latest dic E w hm r Drag to change the column width Search settings file icon Save Cancel 2 Enter a file name and comment and click the Save button The currently specified search folder and search conditions are saved Explanation File List Displays the search settings file name and comments of the search settings saved on the local host Delete bu
28. 3 12 elle 3 2 trend display WINDOW cccccccceceecececeeeeeeeeaeaeeeeneeaeaeaeaenes 3 1 UA EE 3 20 trigger NETS e 3 12 MAISTO aa 3 16 DECHE 3 7 Inder 1 Index U OLS der 4 6 f eebe ee 3 13 Noo viewing a print er ET 3 27 We waveform display are 3 10 waveform display screen 3 4 waveform display zones EEN 3 7 Vo Y axis CIS OY iss ctr nccivaesisaxundataasuncsivsvaivinca ctanadeniciebecetmcnetertinsinieds 3 13 Index 2 IM WX201 01E
29. 315210 DDS 20316350 DDS 0317360 DDS Z0717490 DDS 20718120 DEY 20806120 DEV Z0813500 DDS 20813520 DEV 20817250 DDS 20817360 DEV Z0909400 DDS 20909410 DEV CADAGVVORX DataBrowser data DA OLOGGER 200001 03 0006 mid No Channel Interval sec 0001 TAGO001 4 000sec 0002 TAGO002 1 000sec 0003 TAGOOOS 1 000sec 0004 TAGOO04 4 000sec 0005 TAGO005 4 000sec 0006 TAGOOOE 1 000sec 0007 TAGD007 1 000sec 0008 TAGOOOS 1 000sec 0009 TAGOD09 4 000sec 0010 TAGOO10 1 000sec 0011 TAGO011 4 000sec 0012 TAG0012 1 000sec 0013 TAGOO13 1 000sec Size samples Serial No Start Time 2000 01 03 14 53 01 000 2000 01 403 14 53 01 000 2000 01 403 14 53 01 000 2000 01 03 14 53 01 000 2000 01 03 14 53 01 000 2000 01 403 14 53 01 000 2000 01 403 14 53 01 000 2000 01 03 14 53 01 000 2000 01 03 14 53 01 000 2000 01 03 14 53 01 000 2000 01 103 14 53 01 000 2000 01 03 14 53 01 000 2000 01 103 14 53 01 000 Click a file in the search results area to display its details Resize button Search results File Name Data Type DAGLOGGER 200001 03 0006 mld DAQLOGGER 200001 03 0007 mld 20315210 DDS 0316350 DDS 20317360 DDS Z0717490 DDS Z0718120 DEY 20806120 DEY 20813500 DDS 0813520 DEY 20817250 DDS 20817360 DEY Z0909400 DDS 0909410 DEY na opp DAGLOGGER DAGLOGGER DX100 Dx100 DX100 Dx100 DX100 DxX100 DX100 DX100 DX100 DX100 DX100 Start Time 2000 01 03 14
30. 43 00 0 000 0 063 0 218 2004 12 015 43 0 00 21 16 0 000 2004 1 2 015 43 02 0 000 0 076 0 063 2004 1 2 015 43 0 00 21 16 0 000 2004 1 2 015 43 04 0 000 0 200 0 076 2004 12 015 43 0 00 21 20 0 000 2004 1 2 015 43 06 0 000 O 525 0 200 2004 1 2 015 43 0 00 21 22 0 000 2004 1 2 015 43 08 0 000 0 448 0 325 200471 27015 4939 0 00 21 24 0 000 2004 1 2 015 4310 0 000 0 570 0 448 2004 1 2 015 43 0 00 21 26 0 000 2004 1 27015 4312 0 000 0 689 0 570 2004 1 2 015 43 0 00 21 26 0 000 2004 1 2 015 43914 0 000 0 806 0 689 2004 12 015 43 Notes When Converting Data e There is a limit to the number of data points that Excel and Lotus1 2 3 can handle Before executing the conversion set the channels groups to be converted the conversion range and the step so that the number of data points is appropriate see Automatic Division Function for Conversion Output Files In addition if the free memory space on the PC is low you may not be able to load the data using Excel or Lotus 1 2 3 e f you set the save destination to a storage medium that has slow access such as a floppy disk the saving of the data may take an extended time It is recommended that such storage medium not be selected for the save destination e Select a save destination with adequate free space IM WX201 01E 3 25 3 8 Converting Data Formats Automatic Division Function for Conversion Output Files If the number of points to be converted and outputis large and you attemp
31. 53 01 000 2000 01 03 14 59 41 000 20044 2103 15 21 46 000 20044 2 03 16 35 08 000 20044 2 03 17 36 00 000 20044 2 07 17 49 00 000 20044 2107 18 12 00 000 20044 2 08 06 12 00 000 20044 2108 13 50 10 000 20044 208 13 52 50 000 20044 2108 17 25 20 000 20044 2 08 17 36 30 000 2004 1 2 09 09 40 24 000 20044 2 09 09 41 25 000 Dba AS 200 OON End Time 2000 01 03 14 59 40 000 2000 01 403 15 04 19 000 20044 2 03 16 01 26 000 2004 4 2 03 17 15 24 000 20044 2 07 14 16 00 000 2004 2 08 11 13 00 000 20044 2 08 06 11 00 000 2004 4 2 08 11 13 00 000 20044 208 16 56 30 000 2004 1 2 08 16 56 30 000 20044 2 09 08 58 00 000 2004 4 2 09 08 58 00 000 20044 2 09 11 10 16 000 Comment DX100 12ch Disp 1min div DxX100 12ch Disp 1 min div DX100 12ch Math1 2ch Disp 4hidiy DX100 12 1 2Disp30min divEvent60s DX100 12 1 2Disp30min divEvent60s DX100 12 1 2Disp30min divEvent60s DX100 12 1 2Disp Smin divEvent1 Os DxX100 12 12Disp Smin divEvent1 Os Dx100 12 1 2Disp20min divEvent30s DX100 12 1 2Disp20minidivEvent30s DxX100 12412 Disp2min diy EventSs DxX100 12 12 Disp2min div EventSs DALON Dis Armini Explanation Search Results Area Displays any found files in a list The list is located in the lower left part of the screen File Name The names of the found files Data Type The data type of the found files Start Time The time of the first data in the found files End Time The time of the last data in the found files Ti
32. AQLOGGER Client D Databrowser oof GateCONTROL C GateDXP a GateEye of GateMODBUS 2 Gatemx100 Sc 3 SatewT 0 MXLOGGER Bey DataBrowser Mew Folder Ok Cancel If you do not want to create a new folder skip to step 7 IM WX201 01E 2 23 MOPUIM 493295 leg y JO uoneiado 2 8 Copying Data Files 5 Select a location in which to create a new folder and click the New Folder button The Create New Folder dialog box is displayed Create New Folder 4 xj Enter a name forthe new folder that you wantto create Current Folder CADAGQVWORS DatabrowserdatalTrend Data Mew Folder Name cance 6 Enter the name of the folder to be created and click the OK button The Browse Folders dialog box is displayed the screen in step 4 7 Select the destination folder and click the OK button The Import Data files dialog box reappears Import Data files SOuUrCe A004 CVVORE Veaddhuttiy Select Destination CA DatabrowserdataiTrend DatakiddMuki DOli Select Start Close 8 Click the Start button When copying is complete Completed is displayed in the bottom of the Import Data files dialog box along with the number of copied files Import Data files SOuUrCe ADATA OR A ddia Destination Co DataBrowserwdatalTrend_Dataiaddhutti 001 4 Completed Number of Imported files 5 Start
33. MB G Denotes 1024 M Example 2 GB Bolded Items Description An overview of DataBrowser Provides DataBrowser s PC system requirements and configuration flow of operations and other information Describes methods to search for data files Explains how to search by folder name file date extension data tywi characters serial number and other criteria how to display search results how to add channels to data and other operations Describes how to display data found during a search Explains how to display waveforms cursor values and computed results how to save settings and change data formats and other operations Lists error messages their causes and their corrective actions An alphabetical index of the manual s contents Hardware and software controls that the user manipulates such as dialog boxes buttons and menu commands are often set in boldface type Subheadings On pages in chapters 1 through 3 that describe operating procedures the following subheadings are used to distinguish the procedure from their explanations Carry out the procedure according to the step numbers All procedures are written with inexperienced users in mind dE depending on the operation not all steps need to be taken Explanation gives information such as limitations related the procedure Note Calls attention to information that is important for proper operation of the instrument IM WX201 01E Contents
34. Mean RMS Start Time End Time VM ZHO1 Y Min 2 159 2 156 4 315 0 280 1 459 200442103 15 36 46 000 200442103 15 44 22 000 Max 2 159 2 156 4 315 0 232 1 451 200442403 15 36 46 000 200442103 15 44 22 000 VM HOI Min 0 000 0 000 0 000 0 000 0 000 200442103 15 36 46 000 200442103 15 44 22 000 Max 0 000 0 000 0 000 0 000 0 000 20044203 15 36 46 000 200442103 15 44 22 000 VM ZHO1 Y Min 0 528 2 199 2 727 0 969 1 276 20044208 14 05 10 000 200442908 14 12 46 000 Max 0 451 2 199 2 650 1 005 1 289 20041208 14 05 10 000 20044298 14 12 46 000 wog HOI Min 0 000 0 000 0 000 0 000 0 000 20044208 14 05 10 000 200442908 14 12 46 000 Max 0 000 0 000 0 000 0 000 0 000 20044208 14 05 10 000 20044298 14 12 46 000 es Calculate Close Channel display color Progress bar Specify using two cursors the interval over which computation is to be performed If the cursors are not displayed all the data are used in the statistical computation The statistical parameters are the minimum value the maximum value the P P value maximum minimum the mean value and the rms value The computation is executed when the dialog box is displayed or when you click the Calculate button Channels in Normal format are displayed in a single row Values of channels in MinMax format are displayed in two rows one for the minimum and maximum value at the cursor position Min and Max Shows the maximum and minimum values of the range selected by the cursors or the entire range
35. Procedure 1 Specify search conditions 2 Click the Search within results button in the Search conditions area Geh bel Search subfolders Search Search within results Explanation The Search within results button allows you perform a search of the files found during the previous search This function allows you to do the following e When a large number of search results are obtained you can find desired files by applying new conditions and searching through those results e lf you save the search results See section 2 6 you can perform multiple different searches on those results By combining the Save Open functions with the Search within results function you can create a search results file that fits your particular task Note The Search within results function searches on screen files and does not perform communication Searching within results can be performed on the local data but data from files found on a network host cannot be displayed see chapter 3 To display data the network hosts must be running DataBrowser IM WX201 01E 2 13 MOPUIM y2129S Veq eu JO uoneiado 2 5 Displaying Search Results Displaying File Details Procedure 7 Click a file in the search results area to display its details in the File Details area Click the tag display switching buttons to display the channel Tag No or Tag comment File Details E Host Name Folder ID CPCOO 13666 01 Folder001 Show th
36. The Registration from list tab is displayed Ge Search Path Gonfieuration 10 x New Registration Registration from list Host List Cr Update button Host Mame 1 CPCO01 1 3666 01 localhost A CPCOO1 057135 02 Acquire button Click to select all folders Folder List Holt Mame CDCUUT 1 3666 01 10 0 106 195 E Folder ID Path 1 Folderoo1 CDAGVYOR DataBrow ser data wA Delete button A Folderod2 CH idataiDAGLOGGER Folderoos Cr DataBrov ser data md wiki x aod close Double click number to specify individual folders Drag to select range of folders 3 Select a host from the Host List The folders registered under the selected host appear in the Folder List IM WX201 01E 2 3 MOPUIM y2129S Veq 24 JO uoneiado 2 2 Registering and Specifying Search Folders 4 Selecta folder and click Add or double click the folder number The host name and ID of the specified folder appear in the Search paths area with check box selected Search paths Host Name Folder ID SPCOO1 13666 01 Folderoo ePCOO1 05715 02 Folder B001 Select to assign folders to be searched Drag to change the column width Explanation Host List The Host List displays any hosts on the network that are running DataBrowser Up to two hundred hosts can be displayed Folder List The Folder List displays the folder ID and paths registered to the host sele
37. User s Manual WX201 DataBrowser vigilantplant YOKOGAWA A IM WX201 01E Yokogawa Electric Corporation 6th Edition Notes Trademarks Revisions 6th Edition October 2011 YK This user s manual contains useful information about the functions and operating procedures of the DataBrowser and lists the handling precautions of the software To ensure correct use please read this manual thoroughly before beginning operation After reading this manual keep it in a convenient location for quick reference in the event a question arises during operation e License numbers will not be reissued Please keep your license numbers in a safe place e The contents of this manual are subject to change without prior notice as a result of continuing improvements to the software s performance and functions Display contents illustrated in this manual may differ slightly from what actually appears on your screen e Every effort has been made in the preparation of this manual to ensure the accuracy of its contents However should you have any questions or find any errors please contact your nearest YOKOGAWA representative dealer or sales office e This user s manual does not cover the handling and operating procedures of Windows e Copying or reproducing all or any part of the contents of this manual without YOKOGAWA s permission is strictly prohibited e DAQWORX DAQLOGGER and DAQEXPLORER are registered trademarks or trademarks of
38. Yokogawa Electric Corporation e Microsoft Windows and Windows Vista are registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries e Adobe and Acrobat are registered trademarks or trademarks of Adobe Systems Incorporated e Company and product names that appear in this manual are registered trademarks or trademarks of their respective holders e The company and product names used in this manual are not accompanied by the registered trademark or trademark symbols and e st Edition February 2005 e 2nd Edition June 2007 e 3rd Edition January 2009 e 4th Edition June 2010 e 5th Edition January 2011 e 6th Edition October 2011 All Rights Reserved Copyright 2005 Yokogawa Electric Corporation IM WX201 01E Software License Agreement IMPORTANT PLEASE READ CAREFULLY BEFORE INSTALLING OR USING THANK YOU VERY MUCH FOR SELECTING SOFTWARE OF YOKOGAWA ELECTRIC CORPORATION YOKOGAWA BY INSTALLING OR OTHERWISE USING THE SOFTWARE PRODUCT YOU AGREE TO BE BOUND BY THE TERMS AND CONDITIONS OF THIS AGREEMENT IF YOU DO NOT AGREE DO NOT INSTALL NOR USE THE SOFTWARE PRODUCT AND PROMPTLY RETURN IT TO THE PLACE OF PURCHASE FOR A REFUND IF APPLICABLE Software License Agreement 1 Scope This Agreement applies to the following software products and associated documentation of Yokogawa collectively Software Product Unless otherwise provided by Yokogawa this Agreement applies
39. a File Name Name of the file to which the channel belongs Host Name Name of the host on which the channel to which the file belongs resides Toolbar SR GH da Displays version information Displays the Trend display window Displays the Search window Copies data files Saves Trend settings files Opens Trend settings files Opens new Trend Display window Opens new Search window Display Channel Setting Screen Toolbar for Channel Info and Configure Screens uji E L pieplays channel details ea aei group setting T OFF 1 2 3 4 oves groups A forward backward Switches between Channel dds deletes groups Tag No and Tag Comment Copy Paste Opens the trend display screen Opens the channel setup screen Display Channel Setting Screen Group Tab Toolbar T PS E Ee channels up and down E channels Displays channel display configuration Displays channel information 3 2 IM WX201 01E 3 1 Names of Parts in the Trend Display Window Editing Functions in the Channel Display Configure Screen Copy Click to select all Paste SCO Py ie Grp Name aam S Scale Zone Channel Y Axis Fom Min Max Min Max Trip 1 fa VM T4G0001 Lei Linear 4 200 0 200 0 0 100 200 0 r fa VM T4 G0002 La Linear 4 60 00 60 00 0 100 60 00 fa VM T4 G0003 La Linear 4 2 000 2 000 0 100 2 000 al TAGOOO04 La Linear 4 200 0 200 0 0 100 200 0 Li Y05 00001 La Linear 4 2 0000 2 00
40. ach channel Size samples Displays the number of data for each channel Serial No Displays the serial number for each channel Start Time Displays the time of the first data for each channel End Time Displays the time of the last data for each channel Trigger Time Displays the trigger time for each channel IM WX201 01E IM WX201 01E 2 5 Displaying Search Results Note Tag numbers and serial numbers are not displayed for the following data types Tag numbers CK1000 2000 DX100 200 MV100 200 FX100 Serial numbers DAQLOGGER AddMulti AddTrigger MX100 Serial numbers are also not displayed for computation only data from the MX100 and for data saved by Viewer Show the file information display button Click this button to display the Datafile Information dialog box for the found file Click to select a tab ss jo Title MarkiMessage Comment Marks 1 Batch Information No E Application Supervisor Group Name E Ma Mba W Groups E co No Group Name co 01 Comment Displays the comments title and comment for the selected data file If no data exists nothing is displayed Mark Message Displays the number and text of marks for the selected data file If no data exists nothing is displayed Batch Information Displays the batch information Application Supervisor Manager Batch Name Comment User Comment for the selected data file If no data exists nothin
41. al IM WX201 01E 3 11 MOPUIM Aeldsig pudij au Jo uougiodo H 3 4 Displaying Trends Time Reference Mode There are four time reference modes Start Reference Trigger Reference End Reference and Time Reference Start Reference Waveforms are displayed using the first data of the channels assigned to the group as a reference Trigger Reference Waveforms are displayed using the trigger point of the channels assigned to the group as a reference End Reference Waveforms are displayed using the last data of the channels assigned to the group as a reference Time Reference Waveforms are displayed using the measurement time of the channels assigned to the group as a reference Start reference Trigger reference Y Trigger point End reference Time reference SY NI ONIN a ee Time Save Format of Displayed Data Data files are saved in two formats one for waveform display and one for the cursor value dialog box Data saved in different formats can be displayed in the same Trend display screen The format in which one data is saved per unit of time is called Normal format and the format in which two data a minimum and maximum value are saved per unit of time Is called MinMax format The following shows the correspondence between data types and save formats Data Type Normal Format MinMax Format DX100 Yes Yes MV100 MV200 Yes Yes CX1000 CX2000 Yes Yes FX100 Yes Yes MX100 Yes No DAQLOGGER Yes No AddMulti Yes No
42. annels ii 2 16 automatic GIVISION TUNCUON BE 3 26 AWO Ee 319 C channel display configure screen 3 1 Channel Information Gcreen 3 1 Channel information screen ccccccseseeeeeecceeeeseeeeseananseess 3 1 ele TUG WA 3 15 computed results StatiStiCS 3 19 CONV Le E 3 24 le E 3 3 COV MOANA KE 2 23 D o data display TUNCION wwa wamama wawa wwa wawa kawawa nn ranne nnee 1 1 data search function EE 1 1 data search window 2 1 data type specification ccccccccccccecececeeeeeceeceeeeeeeeneneneeeeeeess 2 8 date and time specification ccccccccccecccececeeeeceeeeneeeneneneness 2 6 different intervals ccccccccccccesseeeesseeeeeeeeeeeseseasaneeseeeeeeees 3 11 display Color E 3 8 displaying cursor va lues ma wwmi ninini ninii 3 17 displaying trendS w wwmwmemwmwnnmazwnww munini nanininwa 3 9 E editing WAA ia 3 3 e EE 3 14 end reference w wwmem meme ww mnamwamini niwa w wina wi nii 3 12 error messages and Corrective achHonsg 4 1 executing the search E 2 11 exiting Kane 1 4 E file COUN Sa esac see ase eeciensaetace esa caede aensai teuctenecdg gseceeceente 2 14 file NAME specification AEN 2 7 ISR AA IA ee eer 2 18 flow of operations E 1 5 folder ID 2 2 TOOTIS E 2 4 THOU TM gt PEE A EEEE acs oe poe OE AE AEA E E E 3 14 G OO OE ee AAA 3 2 group selection tabs osc cenis center oniancdsncscandicaie conte ren
43. as 2 5 Specifying Search ConditionS cccccecccccceceeceeeeeeseseeceeeeeeesaeeaeeseeeeeeeeeeessaeseaeeeeeeeeeeeeeesaeaas 2 6 Specifying a Date and or Time Range ccccccseeesececeeeeeceeeseaeesseeeeeeeeesssesaaaeeseeeeeeeeeeeaeeaas 2 6 Specifying a File Name or Extension 2 7 Specifying Dala E 2 8 Specifying KeywordS ccccccccccecaeseeseeeecceeeeeecseeaeeesceeeceesesseeeeeseseceeeeeesesseaeasseeeeseeeeseseaaeagas 2 8 Specifying a Serial NUMBE E 2 9 Specifying Search CONnditiONS wwwwww wmmmmmmmmwamwmwnnanananuawumununanananumumununananunwa kununa 2 10 Exec tng ihe SAIC ersan AA E EE E EEE 2 11 Displaying Search ET E 2 12 Displaying the Search RE 2 12 Narrowing the Search Results cccccsseeecceceeceeeceeeeeeeeeececeeeeeesseeeaeeeseeeeeeseessseaaaaseeeeeeeees 2 13 Biereg File E ssisnrsscn e Eaa ea ea EE aE 2 14 Adding Channels from Search Results to the Trend Display VWumdow 2 16 Collectively Adding a Selected Range of Channels snssnssnnnnnnneenenssrnrnrnnererensrnnrnrneereee 2 16 Adding Individual Channels ccccccsssssecceecceesseeceeceseesceceeecaaeeseeeeeesuanseseeeessuaeeeeeesaeaaaeees 2 16 Saving and Loading Search Settings and Hesults 2 17 SAVING Search Seting AI 2 17 Opening Search Settings from a Local Host 2 18 Opening Search Settings from a Network Host 2 19 Saving SEAR CMC E 2 20 Opening Search Results from a Local Host 2 21 Opening Search Results from a Network Host 2
44. ata type DataBrowser Keywords Serial numbers Send Convert Print data data Send conditions conditions Host A Host B Data on host B CX DX FX Communication with Network Hosts DataBrowser can communicate with hosts on the network other PCs running DataBrowsers and execute searches obtain data download specified files and acquire search results The following is an description of the communication that occurs when executing functions on a DataBrowser network host from another DataBrowser For each request 1 a connection with the host is made 2 the request is sent and the response is received 3 then the connection is closed The connection with the host is not always open Rather it only opens when the request Is issued Requesting PC PC processing request Requests conection Allows connectiion Sends request Sends results of request Closes connection 1 2 IM WX201 01E 1 2 IM WX201 01E System Reguirements Operating System OS Run DAQWORX under any of the following operating systems Windows 2000 Professional SP4 Windows XP Home Edition SP3 Windows XP Professional SP3 excluding Windows XP Professional x64 Editions e Windows Vista Home Premium SP2 excluding the 64 bit editions e Windows Vista Business SP2 excluding the 64 bit editions e Windows 7 Home Premi
45. ch again Saving and Loading Settings and Search Results Code Description Corrective Action E0211 Cannot write to the file Failed to save the file Confirm that the disc capacity and file system are correct E0212 Cannot read file Confirm that a file exists that the software supports it and whether the file system Is correct E0213 Cannot open the file Confirm that a file exists that the software supports it and whether the file system Is correct E4955 Failed to delete file When files were deleted one or more files could not be completely deleted M4959 No search results Since no search results files are in the data search window search results could not be saved Saving and Loading Settings and Search Results Code Description Corrective Action E4961 Failed to copy data file Failed to copy data file Check whether the disk capacity in the copy destination is sufficient whether the copy destination folder is write protected and whether the file system is correct E4962 The copied data file exists under a different name A data file of the same name was found in the copy destination Change the name In this case save the file in the copy destination under the name copied file name four digit number extension The four digit number starts with 0000 followed by 0001 and so on 4 2 IM WX201 01E Index Index A adding and deleting groups cccccccccccceececeeeececeeeeeeeeeeeeeess 3 5 adding ch
46. cted in the host list Up to two hundred folders can be displayed Update button red circular icon Updates the host list and folder list Update button green arrow icon Updates the folder list for individual hosts Remove button Deletes folders from the folder list You can only delete folders registered to the local host Add button Adds the folder specified in the folder list to the Search paths list in the Search window Registering a Folder from the Explorer Procedure 1 Open the Search window Drag a folder you wish to register from the Windows explorer from a folder onto the Search window The Reg of search paths dialog box is displayed Search window GESTS ale ES 7 DataBrowser Search New File Edit Weu Favorites Tools Help File View Window Hel z K F E o R D Back Q Search h Folders ESnistory AS OS X A S kuu address C paqworx x oe Search paths Fold z olders Host Name CC DAQWORX PESSE AddMulti File Folder e C Addmutti g C addobserver Runtime File Folder IT C Addobserver Runtime AddQbserver File Folder TC C Addobserver Bareak EEGEN File Folder EI C AddTrigger 21D4032Plus File Folder SS CI DAQ32Plus 241 CI DAQ32Plus client File Folder w CI DAQ32Plus Client DAQEXPLORER File Folder e CI DAQEXPLORER apen File Folder F A iT DAQLOGGER Client File Folder T Bi A SS DataBrowser F
47. data file Blank data type not included Note e You can specify multiple keywords by separating them with a space e If multiple search keys are selected the software searches for files whose keywords are found in data corresponding to all of the keys e Up to one thousand marks messages can be found per file All other marks or messages thereafter are not found Specifying a Serial Number Procedure 1 Specify a search folder See section 2 2 2 Select the Serial No check box in the Search conditions area 3 Click the Serial No tab or click the words Serial No to the right of the check box The Serial No tab is displayed Check box Search conditions za x P SS m Time Fie Name Data Type Keywords Serial No E Time No 1 No 2 014123456 ee B File Name No 3 No 4 Il Data Type Keywords Search subfolders Search Search within results Click to the right of each item to change the tabs on the right 4 Enter a serial number Explanation Serial number specification allows you to search for data files of the specified instrument serial number Note e DAQLOGGER AddMulti and AddTrigger do not have serial numbers and therefore data acquired by those programs cannot be searched for using this criterion e Enter the serial number carefully as only exact matches will be found IM WX201 01E 2 9 MOPUIM y2129S Veq eu JO uoneiado H 2 3 Specifying Search Conditions Specify
48. dudesnamndcaest 3 10 FO WA UA EE 2 4 Pe intersection between waveform ANd cursor 3 13 K keyword specification cceeeee cece ee eeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 2 9 IM WX201 01E ee linked group SC ee EE 3 5 MN minimum and maximum values of scale 3 7 WI WE ONS E 3 15 multiple search conditions eee 2 10 HN normal format indstop and indstart MinMax format 3 13 O Opening Search Hesuhts nennen ennnen eeren 2 22 opening search EE 2 21 Opening Search SON VS 2 19 opening search E lu 2 18 opening trend settings ccecccccccccccccececececeeeeeeceeeeeeeeeeeeness 3 21 overview of UDatatiroweer AANEREN 1 1 P SE 3 3 KINGA AI 3 27 SAA leen EE 2 20 saving search settings E 2 17 Aa li aaa 2 6 IAA 2 2 search paths E 2 2 search resule eege eege 2 12 search within CSUN eegent iere be Etgen 2 13 serial number specification 2 nnn rn rnrn nn nnne 2 9 settings in the channel setup screens cceeeeeeseeeeeee 3 6 showing channel details 3 8 Sido eet 3 14 SOMW ANS ICONS AA li SO EEN 2 13 specifying DADC S re cenaieiatynncecexcxnciosnnpecseennncastomnpanneete aaxrexevecd 2 13 start and end points EE 3 24 starting the e 1 4 Stan To Or Eegeregie 3 12 SAUS MONT AI 2 11 E aE S e PE T E EAE A E T 3 24 SOTE AA 2 10 system requirements enee gees egresegee eher Geer 1 3 Po time axis display E 3 10 Ume relerenCE nicissita iiie iaia 3 12 time reference mode
49. e F OF o8 K i 10 Ka 1 4 eee eae Group Name Group E ei ei No Channel Y Axis Fom E WT CHO Linear E woz cho Linear d fai VS CHO Linear 4 nad OL Ween A 3 5 MOPUIM Aeldsig pudij au jo uougiodo H 3 3 Swich between the display channel settings screen and waveform display screen Set linked groups OFF 1 2 3 4 Add delete move forward backward groups Settings in the Channel Setup Screens You can edit display settings by following the indications in the figure below am E l l x mag 3 Display channel details mm ere the displayed group Channel Start Time End Time Trigger Time Interval sec 2004 12 03 15 21 46 000 2004 12 03 16 01 26 000 2004 12 03 16 01 26 000 2 001 2004 12 03 15 21 46 000 2004 12 03 16 01 26 000 2004 12 03 16 01 26 000 2 001 2004 1 2 08 13 50 10 000 2004 1 2108 16 56 30 000 2004 12 08 16 56 30 000 10 001 Select channels Switch between the channel Information and Select clear all channels channel display configure screens B File View Window Help e x SR GN oe AA 2 kuiuzia Delete channels or move them up and down Hao os Group Name eras Channel Trip 1 Trip 2 Color Turn trip point ON OF Specify a waveform display zone Select channels Turn waveforms ON OFF Turns the Y axis ON OFF when in multi zone display Select a scale value display i
50. e button File List Trend settings file amp Update button File Name Comment Sse MATOO View 4001 dby Trend Feb 09 2005 Aa METOO Vievw 4002 diy Trend Feb 09 2005 Max O0 Yievy 4 003 dby Trend Feb 09 2005 Trend 4 001 Odre Feb 14 2005 Trend 4 002 Odre Feb 14 2005 latest Ob Trend Feb 09 2005 lekkk Drag to change the column width Save Cancel 2 Enter a file name and comment and click the Save button The currently displayed trend settings are saved File List Displays the trend settings file name and comments saved on the local host Delete the selected file button Deletes the selected trend settings file Update button Updates the trend settings file list File Name Enter the name of the file you wish to save an extension is automatically added Comment Enter comments to be saved with the file Up to 255 alphanumeric characters can be entered Save button Saves the settings file under the specified file name on the local host Note After saving a trend settings file the saved file name and comment appears in the text box the next time you open the Save the trend settings dialog box these items are blank if no settings have been saved previously or when starting up the software Also when you select a file in the Save the trend settings dialog box the file and comment are displayed in the input boxes at the bottom of the window This allows you to conveniently overwrite settin
51. e file information display E Channels button File Name CDA VVORX DataBrowserWdata DAGLOGGER 200001 03 0006 mld Tag display mea sa switching buttons Explanation No Add Interval sec Size samples Serial No Start Time 0001 TAG0001 1 000sec 400 2000401403 14 53 01 000 0002 TAGO002 1 000sec 400 2000 01 403 14 53 01 000 0003 TAGOO0S 1 000sec 400 2000 01 403 14 53 01 000 0004 TAGODO4 1 000sec 400 2000 01 403 14 53 01 000 0005 TAGOOOS 1 000sec 400 2000 01 03 14 53 01 000 0006 TAG000G 1 000sec 400 2000401403 14 53 01 000 0007 TAGOOOF 1 000sec 400 2000 01 03 14 53 01 000 0008 TAGO008 1 000sec 400 2000 01 403 14 53 01 000 0009 TAG0009 1 000sec 400 2000 01 03 14 53 01 000 0010 T4G0010 1 000sec 400 2000 01 403 14 53 01 000 0011 TAG0011 1 000sec 400 2000401403 14 53 01 000 0012 TAG0012 1 000sec 400 2000401403 14 53 01 000 0013 TAG0013 1 000sec 400 2000 01 03 14 53 01 000 fae Yi Host Name Folder ID Displays the host name and folder ID Channels Displays the number of channels in the current file File Name Displays the path and file name of the current file No A number for the files in the list Add A button for adding the item to the trend display See section 2 7 Tag display switching buttons Channel Displays the channel numbers Tag No Displays the tag numbers Tag Comment Displays the tag comments Interval sec Displays the save interval for e
52. e of the zones individually By dragging the zone you can change its position without changeing the range Full Zone Displays all the waveforms over the full zone of the waveform display area regardless of the Zone settings on the Channel display configuration screen A single Y axis of the active waveform is displayed Active Y axis mar ae d Waveform display area full zone Displays the Y axis of the active channel Slide Zone Displays the waveforms by slightly offsetting the display position of each waveform vertically regardless of the Zone settings in the Channel display configuration screen A single Y axis of the active waveform is displayed Active Y axis mar The waveform of each channel are offset in this manner BSI WX201 01E WX201 01E 3 4 Displaying Trends Auto Zone Displays the waveforms by dividing the waveform display area evenly according to the number of displayed waveforms regardless of the Zone settings in the Channel display configuration screen Active Y axis mar Automatically displays the waveformin equal divisions CS Multi Zone Arranges all the Y axes from left to right displaying all specified Y axes Y axes not selected in the Channel display configuration screen are not displayed The display range is set using the Zone parameter in the Channel display configuration screen When you drag a Y axis button onto the Y axis display area the Y axis of the relevant chan
53. ecifying Search Folders Add button The Search Path Configuration dialog box is displayed when this button is clicked Remove button Deletes the selected folder registration from the Search paths area Search source check boxes Select or clear the check boxes to include or exclude folders from searches Search Path Configuration Dialog Box Update button Updates the directory tree for the local host Folder ID Box You can enter an identifying string for the folder using up to sixteen alphanumeric characters The folder ID is registered along with the folder Add button Registers the selected folder using the specified folder ID Close button Closes the Search Path Configuration dialog box Note e Two or more folders cannot be registered under the same folder ID e Registered folders are shown under Folder List in the Registration from list tab of the Search Path Configuration dialog box Up to two hundred folders can be registered If you need to register a new folder when two hundred have already been registered first delete one or more of the registered folders from the folder list Specifying a Folder from the List The following is the procedure for selecting a search folder from the list of registered folders from local or network hosts Procedure 1 Open the Search window then click the Add button in the Search paths area The Search Path Configuration dialog box is displayed 2 Click the Registration from list tab
54. ection 2 7 Register and specify search Save and load search folders conditions and result Searches within search results See section 2 3 Specify search conditions See section 2 3 Specify search conditions See section 2 4 Execute searchs See section 2 5 Display search results See section 2 6 See section 2 8 Add channels from search Dopv data files results to the trend display py See section 3 2 See section 2 5 Narrow the search results Select group for adding channels See section 3 3 Channel display configure screen settings See section 3 4 Trend display screen Display cursor Display computed Save and load Convert data Print the data values results trend setting formats See section 3 5 See section 3 6 See section 3 7 See section 3 8 See section 3 9 1 5 J smo geeq y Buisn 310439 E Chapter 2 2 1 IM WX201 01E Operation of the Data Search Window Names of Parts in the Data Search Window Menu bar Toolbar r Search paths area Search conditions area laj xi 18 x Search paths Search conditions Time File Name Data Type Keywords Serial No Host Name Folder ID C Time ped Time Range O File Name C Data Type HECK IA C Serial No Add Remove File Details Host Name Folder ID Channels E File Name Search results File Name Resize button Show the file in
55. ed to upgrade the Software Product or make the Upgrade available to you 4 3 Certain maintenance service may be available for some types of Software Product at Yokogawa s current list price Scope and terms and conditions of the maintenance service shall be subject to those separately provided by Yokogawa Unless otherwise provided in Yokogawa catalogues or General Specifications maintenance services will be available only for the latest version and the immediately preceding version In no event will service for the immediately preceding version be available for more than 5 years after the latest version has been released In addition no service will be provided by Yokogawa for the Software Product which has been discontinued for more than 5 years Notwithstanding the foregoing maintenance service may not be available for non standard Software Product Further in no event shall Yokogawa provide any service for the Software Product which has been modified or changed by any person other than Yokogawa IM WX201 01E Software License Agreement 5 Infringement 5 1 If you are warned or receive a claim by a third party that the Software Product in its original form infringes any third party s patent which is issued at the time of delivery of the Software Product trade mark copyright or other intellectual property rights Claim you shall promptly notify Yokogawa thereof in writing 5 2 If the infringement is attributable to Yokogawa Yokogawa will defe
56. ehalf of you d not complying with Yokogawa s suggestion or el any other causes not attributable to Yokogawa 5 5 This section states the entire liability of Yokogawa and its suppliers and the sole remedy of you with respect to any claim of infringement of a third party s intellectual property rights Notwithstanding anything to the contrary stated herein with respect to the claims arising from or related to the Third Party Software or OSS the special terms and conditions separately provided for such Third Party Software or OSS shall prevail 6 Limitation of Liability 6 1 EXCEPT TO THE EXTENT THAT LIABILITY MAY NOT LAWFULLY BE EXCLUDED IN CONTRACT YOKOGAWA AND SUPPLIERS SHALL NOT BE LIABLE TO ANY PERSON OR LEGAL ENTITY FOR LOSS OR DAMAGE WHETHER DIRECT INDIRECT SPECIAL INCIDENTAL CONSEQUENTIAL OR EXEMPLARY DAMAGES OR OTHER SIMILAR DAMAGES OF ANY KIND INCLUDING WITHOUT LIMITATION DAMAGES FOR LOSS OF BUSINESS PROFITS BUSINESS INTERRUPTION LOSS OR DESTRUCTION OF DATA LOSS OF AVAILABILITY AND THE LIKE ARISING OUT OF THE USE OR INABILITY TO USE OF THE SOFTWARE PRODUCT OR ARISING OUT OF ITS GENERATED APPLICATIONS OR DATA EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES WHETHER BASED IN WARRANTY EXPRESS OR IMPLIED CONTRACT STRICT LIABILITY TORT INCLUDING NEGLIGENCE OR ANY OTHER LEGAL OR EQUITABLE GROUNDS INNO EVENT YOKOGAWA AND SUPPLIER S AGGREGATE LIABILITY FOR ANY CAUSE OF ACTION WHATSOEVER INCLUDING LIABILITY UNDER CLAUSE 5 SHALL
57. formation display button Channel Interval sec Ca ia ui uo _ Keywords Time Range each day Les Co el sl El Search subfolders Search Search within results Size samples Serial No Start Time Open Save Ready 5 6 Search results area File details area Menu bar File View Window Help 1 Open Girl 8 Search display Cascade 10 About 9 Trend display Tile Horizontally EE a 2 New search configuration EE Tile Vertically e Toolbar e Status Bar 3 New trend configuration 4 Save search settings ase 5 Open the search results 6 Save the search results as 7 Import Data files Exit Toolbar oo om op ee GH go B 8 9 10 Bi 1 Loads search settings from local or network hosts and displays them 2 Opens a new Search window 3 Opens a new Trend display window 4 Saves search folder and search condition settings to the local host 5 Loads search results from local or network hosts and displays them 1 Search New config 2 Trend display 6 Saves search results to the local host 7 Copies data files from a specified folder to another folder 8 Displays the Search window 9 Displays the Trend Display window 10 Displays version information MOPUIM 493295 leg y JO uoneiado 2 2 Registering and Specifying Search Folders You can register source folders for data file searches Up t
58. g box 2 21 MOPUIM YD19S leg y JO uonedo 2 7 Saving and Loading Search Settings and Results Opening Search Results from a Network Host Procedure 7 Click the Open button in Search results area or choose File gt Open the search results from the menu bar The Open dialog bor is displayed 2 Click the Hosts on network tab The Hosts on network tab is displayed 3 Click the Update button The names of hosts running DataBrowser and their corresponding files names and comments are displayed d Open pi Local Host Hosts on network Host List Update button Host Mame 1 PCO 05713 02 Double click a number to open the file Drag to change the column width File List Host Mame CPlO01 05713 02 File Mame Comment 1 1000 8001 SearchResuts Feb 04 2005 A Fx100 B001 SearchResults_Feb 04 2005 2 MX100 6001 SearchResults_Feb 04 2005 Ji Open Cancel 4 Selecta host from the Host List The a list of files saved on the selected host is displayed 5 Select a file from the list that you wish to load and click Open or double click the file number The Information dialog box opens LI x Bp Map Replace the current search result with the selected result 6 Click the Yes button The search results loaded from the search results file are displayed Click No to close the Information dialog box Explanation Host List
59. g is displayed Group Name Displays the number and names of groups for the selected data file If no data exists nothing is displayed 2 15 MOPUIM 493295 Beg y JO uoneiado H 2 6 Adding Channels from Search Results to the Trend Display Window The following describes the procedure for adding channels from the search results to the Trend display window Collectively Adding a Selected Range of Channels Procedure 1 Select a file from the search results area to display its details See section 2 5 2 Select a range of channels to add and click the Add channels to this trend configuration buiton Add channels to this trend configuration button Ee JS Click to select clear wo Add Channel all channels 0001 TAGDODI 0002 TAGO0D2 0003 TAG0003 0004 TAGo004 0005 TAGO005 0006 TAGOOO5 Drag to 0007 TAGOOO select range 0008 TAGOOOS 0008 TAGo005 0010 TAGO010 0011 Topp 0012 TAGO02 0013 T d Adding Individual Channels Procedure 1 Select a file from the search results area to display its details See section 2 5 2 Click the Add button next to the channel to add or double click its number Add button Double click ts crs pe g Ele Zi Ma fl Ia Channel Ni Add Channel 0001 TA O01 TA amp G0001 0002 Sas Click the Add 0002 TAGOOO2 0003 TAG0003 buttons 0003 TASO 0604 TAGODD4 0604 TAGOO04 OO05 TAGOONS 06
60. group The name displayed is the one specified in the channel setup screen Waveform Display Area The area in which the waveforms are displayed Displays waveforms according to the settings in the channel setup screens Click in the waveform display area to display a cursor Drag the cursor to display a second cursor Cursor A appears at the position where you first clicked Cursor B appears at the position where you released the mouse button See section 3 5 Displaying Cursor Values Alarm Display Area The area in which the alarms are displayed Toggle the display using the Alarm ON OFF button on the toolbar Y Axis Display Area The area in which the Y axes are displayed The Y axes are shown in the specified colors If the trend display is user zone edit zone full zone or slide zone only the Y axis of the active channel is displayed For auto zone or multi zone all channels are displayed Time Axis Display Area The area in which the time axis is displayed You can select the display range using the scroll bar Toggle the display between absolute time and relative time display using the button on the toolbar 19 15 00 19 30 00 01 00 00 01 15 00 Relative Time DAY him Absolute Time fm sl Zone Display Area The area in which the display status of each channel can be changed Active Y Axis Mark The channel with this mark is the active channel The waveform and alarm data of the active channel are displayed in front G
61. gs IM WX201 01E 3 7 Saving and Loading Trend Settings Opening Trend Settings from a Local Host Procedure 1 Click Ga the Open button in the DataBrowser window or choose File gt Open from the menu bar The Open dialog box is displayed i Ope re ai Delete button Local Host Hosts on network File List t C Update button File Name Comment 122 MIX OO Yiew S001 Ou Trend Feb 09 2005 2 ae MT OO view 4 002 dby Trend Feb 09 2005 3 Ky MSA O0 view 4 003 dby Trend Feb 09 2005 4 SE Trend A001 db Feb 14 2005 522 Trend AD02 dhw Feb 14 2005 Ei SE latest dby Trend Feb 09 2005 E Drag to change the column width Double click a number to open the file Pe JK File Type Trend settings ler db Open Cancel 2 Selecta file and click Open or double click the file number The Information dialog box opens LI x Ls 1 mose Replace the current trend settings with the selected settings 3 Click the Yes button The trend settings loaded from the trend settings file are displayed Click No to close the Information dialog box Explanation File List Displays the name of the settings file and comments saved on the local host Delete the selected file button Deletes the selected file Update button Updates the displayed file list File Type If you select all files dbc dbv the saved search settings files and display settings files are displayed If y
62. gt Channel display format floating point or exponeial color Select Y axis type linear or logarithmic Explanation Display Hide Channels By selecting and clearing the check buttons in the No column on the channel display configure screen you can select whether to display those channels data in the Trend display screen Channel Tag Number and Tag Comment Can be selected deselected for display The Channel column displays the channel tag number and tag comment Display Hide Y Axis and Type By selecting and clearing the check buttons in the Y axis column you can select whether to display the Y axes of the corresponding channels in the Trend display screen This setting is only valid if multiple zones are specified in the Trend display screen 3 6 IM WX201 01E 3 3 Settings in the Channel Setup Screens IM WX201 01E Minimum and Maximum Values of Scale and the indstart Scale Value Display Format instop You can set the maximum and minimum values of the scale when displaying waveforms The value in the Scale Min column is the lower end of the Y axis and that of the Scale Max column is the upper end In the Form column you can specify floating point or exponential format for the scale values Selects exponential display Waveform Display Screen Scale Fom Min Max 2 OO0EO 2 0000 2 000 2000 Setting the Waveform Display Zones You can set waveform display range for displaying trends The waveform displa
63. ications Check whether TCP IP is operating normally M4959 Cannot exit while DataBrowser is starting up Close DataBrowser then shut down or log off Search Folder Registration Code E4925 E4940 E4957 E4960 Description No more search folders can be registered Same folder ID already exists Check the list of registered folders Same folder ID already exists Check the search folders Limit of folders that can be registered exceeded Executing Searches Code E4907 E4939 E4942 E4945 E4946 IM WX201 01E Description No response Folder ID not found Folder not found Failed to write file Connection failure Corrective Action The limit of eight folders that can be registered in the search folder registration area has been reached If you need to register a new folder first delete one or more of the folders first A folder with the same ID has already be registered in the search folder registration dialog box Either delete the existing folder from the list or register the new folder using a different ID Same folder ID already exists in the search folder registration area Therefore the new one cannot be registered Delete the folder with the same ID from the registration area or register the new folder using a different ID If registering with a different ID use a folder ID not already listed in the registration area If more than two hundred folders would be registered registrati
64. ile Folder K GateCONTROL File Folder iy Set ATR C Gatepxp File Fold Getzbxp a cit ji S ei a o GateEye gars es Folder TRETRY O a GateMODBUS GateMODBUS Flle Folder Wi HA C Gatemx100 C Gatemx100 File Folder Pre X Fila cea b D g My Computer a 9 4 IM WX201 01E Explanation 2 Path 2 2 Registering and Specifying Search Folders gr Ree of search paths p JO x Input Folder ID Path Falder ID 1 C1 iDetabrowserdataiDAGLOGGER Folder CcO04 2 CA iDetaBrowseridataaddTrigger Folder CO02 Enter folder ID 3 CL WDetaBbrowseridataAddMuttit Folder Co03 Add Cancel Enter a folder ID and click the Add button The host name and ID of the registered folder appears in the Search paths area the folder s check box is selected indicating that it will be included in any searches performed The Path column shows the absolute path to the folder that was dragged Note Two or more folders cannot be registered under the same folder ID Registered folders are shown under Folder List in the Registration from list tab of the Search Path Configuration dialog box Up to two hundred folders can be registered If you need to register a new folder when two hundred have already been registered first delete one or more of the registered folders from the folder list Notes When Registering Search Folders Note IM WX201 01E Even if you delete a folder from the Search paths area the folder is
65. ing Search Conditions Explanation Specifying Multiple Search Conditions You can apply multiple or even all entered search conditions to the same search including date and or time file name data type keyword and serial number As in the figure below the major search categories are combined in an AND relationship and the conditions within each category are applied in an OR relationship When specifying search items for example date time and data type files with data from the specified date time and of the specified data type are found When specifying search conditions within a tab for example two or more data types files of any of the specified type are found Search conditions Time FileName Data Type Keywords Serial No LI LI o Ze Time e e e DAGLOGGER AddMutti C Fie Name Mi Mi C AddTrigger KL mx100 H Z Data Type mps DK100 200 C mv100 200 e C cx1000 2000 C Fx100 Keywords s H H e Serial No Search subfolders Search Search within results AND relationship OR relationship Searching Subfolders If you select Search subfolders any subfolders existing in the registered search paths are included in the search If Search subfolders is not selected any subfolders within the primary search folders are not included If Search Subfolders is Cleared e Searches only the files within the specified folder e Data files 1 to 9 are not searched
66. lected in the host list Host Name Displays the name of the host selected in the host list Update button Updates the host list and file list File Type Open Button and Cancel Button See Opening Search Settings from a Local Host 2 19 MOpUIM 493295 leg y JO uoneiado 2 7 Saving and Loading Search Settings and Results Saving Search Results Procedure 1 Click the Save button in Search results area or choose File gt Save the search results as from the menu bar The Save dialog box appears File List een Delete button Seach results file w l a Update button File Mame Comment 1 Addhtiuti 4001 SearchResuts Feb 08 2005 A AddTriggeri A001 SearchResuts Feb 08 2005 3 DASLOGGER 4001 SearchResutts _Feb 06 2005 d MX100 40014 searchResults_Feb 06 2005 Drag to change the column width Save Cancel 2 Enter a file name and comment and click the Save button The displayed search results are saved Explanation File List Displays the name of the search results file and comments saved on the local host Delete button Deletes the selected search results file Update button Updates the displayed search results file File Name Enter the name of the file you wish to save An extension is automatically added Comment Enter comments to be saved with the file Up to 255 alphanumeric characters can be entered Save button Saves the search res
67. n thin the data by outputting only the points sampled at certain intervals 3 24 IM WX201 01E 3 8 Converting Data Formats The figure below shows an example of output when the Write Measured point of the following channel check box is not selected the smallest unit interval reference interval is 0 5 s and the number of steps is 1 if the steps were set to 3 samples would be output every 1 5 s Minimum unit interval oe 0 5s 3 3 3 3 3 3 CHO1 1 5s d a e i y i CH02 0 5s a i i i i 4 4 4 4 4 o CH03 1 0s i i i i i iSS CH04 2 0s g e CHO05 1 5s AV Y Y Y Y Y Y Y Y Y Y Output 0 5 s 0 Measurement point of each channel The squares represent the output of measured points on each channel 0 5 s If the Write Measured points of the followimg channel check box is selected and channel 3 is also selected measured points on each channel are output every 1s Note e Ifthe output points are not measured points the points directly after are output e When the Write Measured point of the following channel check box is selected the start and end times on the right are those of the selected channel Example of the Converted Data MOPUIM Aejdsig pudijl y jo uogiedo WA Measurement data Channel CH01 CHO02 TagNo 50 TagComment 1 Unit V V 52 JInterval Sec 2 000 2 000 gt 3 Days Time Second Date Time Second Value Min Value Max Date Time 0 00 21 14 0 000 2004 1 2 015
68. nd you from the Claim at Yokogawa s expense and indemnify you from the damages finally granted by the court or otherwise agreed by Yokogawa out of court The foregoing obligation and indemnity of Yokogawa shall be subject to that i you promptly notify Yokogawa of the Claim in writing as provided above ii you grant to Yokogawa and its designees the full authority to control the defense and settlement of such Claim and iii you give every and all necessary information and assistance to Yokogawa upon Yokogawa s request 5 3 If Yokogawa believes that a Claim may be made or threatened Yokogawa may at its option and its expense either a procure for you the right to continue using the Software Product b replace the Software Product with other software product to prevent infringement c modify the Software Product in whole or in part so that it become non infringing or d if Yokogawa believes that a through c are not practicable terminate this Agreement and refund you the paid up amount of the book value of the Software Product as depreciated 5 4 Notwithstanding the foregoing Yokogawa shall have no obligation nor liability for and you shall defend and indemnify Yokogawa and its suppliers from the Claim if the infringement is arising from a modification of the Software Product made by a person other than Yokogawa b combination of the Software Product with hardware or software not furnished by Yokogawa c design or instruction provided by or on b
69. nel is displayed Conversely if you drag a Y axis onto the zone display area the Y axis of the relevant channel is hidden Drag the Y axis button of the Y axis that is not displayed onto the Y axis display area to display it again Active Y axis mark The Y axis of the active channel is displayed on the far right If you drag the Y axis display onto the zone display area the Y axis is hidden Clip Function Turning ON the clip function forces displayed points on the waveform that fall outside of the scale range to revert to the max or min value of scale Use the Clip button on the toolbar to turn the clip function ON and OFF Clip OFF initial setting Clip ON IM WX201 01E 3 15 MOPUIM Aejdsig pues y Jo uoneo H 3 4 Displaying Trends Trip Point The trip points are displayed according to the Trip 1 and Trip 2 settings in the Channel display configuration screen You can drag the trip 1 and trip 2 displays to change them These changes are reflected in the Trip 1 and Trip 2 items in the Channel display configuration screen E Trip 1 Ra Trip 2 You can change the trip point by dragging Copying the Trend Display Clicking the XX button copy button in the Trend display toolbar copies the displayed trend screen You can paste the copied screen onto a standard Paint program that comes with your operating system ei untitled Paint 3 21 26 50 21 27 00 2000 01 02 Absolute Time h m s
70. ng the Software Starting the Software Procedure 1 From the Windows Start menu choose Programs gt YOKOGAWA DAQWORX gt DataBrowser gt DataBrowser DataBrowser starts gt DataBrowser Search New config WE UJI 5 x Fj File View Window Help la x SR GHz BR Search paths Search conditions Hos Nana Folder ID Time File Name Data Type Keywords Serial No C Time bed Time Range F aa __2005 _2 _8 L11 Lo4 L25 Data Type ad 24 ai L11 Lo4 25 keywords Time Range each day Il oa 25 HUH a E _ Serial No Add Remove _ Search subfolders Search Search within results File Details E Host Name Folder ID Channels E File Name Search results File Name Channel Interval sec Size samples Serial No Start Time oe Save Ready Note When you start DataBrowser it is restored to the same configuration that was active during the previous session However the search results in memory when exiting the software cannot be recovered in subsequent sessions Exiting the Software Procedure 1 Choose File gt Exit from the menu bar or click the XJ button at the right end of the title bar DataBrowser closes 1 4 IM WX201 01E 1 4 IM WX201 01E Flow of Operations The figure below shows the general flow of operation when using DataBrowser See section 1 3 Start DataBrowser See section 2 2 See s
71. o two hundred folders can be registered and up to eight of those can be specified at a time for a search Registering New Search Folders Procedure Explanation The following is the procedure for registering new source folders for searches on local or network hosts 1 Open the Search window then click the Add button in the Search paths area The Search Path Configuration dialog box is displayed ge Search Path Configuration _ O x New Registration Registration trom list Select a search path Update button L Addhutti Ja Addobserver Ja AddObserver Runtime JS AddTrigger H DAG32Plus 4 Daaa Plus Client T DAGEXPLORER DAGLOGGER AM DAGLOGGER Client Ce Databrowser fat E af RITE A Folder ID Folder 001 Folder ID box Select a folder to register then enter a folder ID Click the Add button The host name and ID of the registered folder appears in the Search paths area the folder s check box is selected indicating that it will be included in any searches performed Search paths Host Mame Folder ID Le CPCO01 1 3666 01 Konen Select to assign folders to be searched Drag to change the column width UVT Add Remove Search Paths Area Host Name The name of the host of the registered folder Folder ID The name specified for the folder when it was registered IM WX201 01E 2 2 Registering and Sp
72. on is denied If you need to register a new folder first delete an existing one from the folder registration list in the search folder registration dialog box Hunooysajgnojj DH Corrective Action Check whether the network is connected correctly cables hubs and other hardware and that no problems occurred on the network On the host on which the error occured the search could not be performed because the folder ID does not exist in the folder registration of the DataBrowser being run Register the search folder on the DataBrowser on the host on which an error occured Check whether the folder exists on the DataBrowser on the host on which an error occured Failed to write the search results file Confirm that the disc capacity and file system are correct Check whether the host on which an error occured exists If it exists check whether DataBrowser is running on that host Check whether the network is connected correctly cables hubs and other hardware and that no problems occurred on the network 4 1 4 1 Error Messages and Corrective Actions Code Description Corrective Action E4947 DataBrowser not found Software may be running on the same port 50285 used by DataBrowser Check the host on which the error occured E4956 The number of data files that meet the criterion If the number of data files that meet the search exceeded the limit the upper limit of 60000 narrow down your search conditions and perform the sear
73. ou select Search settings file dbc only the search settings files are displayed If you select Trend settings file dbv only the display settings files are displayed Open button Opens the settings file selected in the File List When a trend settings file is opened the Trend display window becomes active When a search settings file is opened the Search window becomes active Cancel button Closes the Open dialog box IM WX201 01E 3 21 MOPUIM Aeldsig Dua au Jo uougiodo H 3 7 Saving and Loading Trend Settings Opening Trend Settings indstop from a Network Host Procedure Explanation 3 22 1 Click Ga on the toolbar or choose File gt Open from the menu bar The Open dialog box is displayed Click the Hosts on network tab The Hosts on network tab is displayed Click the Update button The names of hosts running DataBrowser and their corresponding files names and comments are displayed d Open pi Local Host Hosts on network Host List r Update button Host Mame 1 CPCOO1 05713 02 Double click a number to open the file Fle List Drag to change the column width Hist Mame CPCO01 05713 02 File Mame Comment 122 MEN O0 View BO01 dby Trend Feb 06 2005 2 OS ME O0 View BO02 dby Trend Feb 06 2005 File Type Trend settings filet db Open Cancel 4 Selecta host from the Ho
74. py protection used or provided in the Software Product or f to remove any copyright notice trademark notice logo or other proprietary notices or identification shown in the Software Product 2 3 Any and all technology algorithms know how and process contained in the Software Product are the property or trade secret of Yokogawa or licensors to Yokogawa Ownership of and all the rights in the Software Product shall be retained by Yokogawa or the licensors and none of the rights will be transferred to you hereunder 2 4 You agree to maintain the aforementioned property and trade secret of Yokogawa or licensors and key codes in strict confidence not to disclose it to any party other than your employees officers directors or similar staff who have a legitimate need to know to use the Software Product and agreed in writing to abide by the obligations hereunder 2 5 Upon expiration or termination of this Agreement the Software Product and its copies including extracts shall be returned to Yokogawa and any copies retained in your computer or media shall be deleted irretrievably If you dispose of media in which the Software Product or its copy is stored the contents shall be irretrievably deleted 2 6 The Software Product may contain software which Yokogawa is granted a right to sublicense or distribute by third party suppliers including affiliates of Yokogawa Third Party Software If suppliers of the Third Party Software Supplier provide special
75. rid Color Adjustment Slider Drag the slider up and down to adjust the grid color between white and black Background Adjustment Slider Drag the slider up and down to adjust the background color between white and black Y axis button Each channel has its own color coded button Click a button to make its channel active The active Y axis mark moves to the top of the clicked button Zone Display Bar Click to show or hide the zone display area Zone Size Bar Drag to change the width of the zone display area Show Hide Waveform Buttons Click to show or hide channels These buttons mirror the waveform display ON OFF buttons in the channel display configuration screen Trip Point Display Area Displays trip points Mark Display Area Displays marks All marks of the channels registered to the displayed groups are displayed Up to one thousand marks per channel can be displayed and they can be added edited or deleted here When marks are displayed on top of one another the mark of the active channel is displayed in front 3 10 IM WX201 01E 3 4 Displaying Trends Time Axis Display Area e The time display shows the time of the channel When the time reference mode is Start Reference Trigger Reference or End Reference the time of the active channel is displayed e The time display shows the time relative to the start of the waveform display area Showing Channel Details In the Trend display screen the information of the active channel is displa
76. s_Feb 07 20 5 Drag to change the column width Double click a number to open the file File Type Search settings filel dbc Open Cancel 2 Selecta file and click Open or double click the file number The Information dialog box opens Information x 3 mags Replace the current search settings with the selected settings 3 Click the Yes button The search paths and search conditions loaded from the search settings file are displayed Click No to close the Information dialog box Explanation File List Displays the name of the settings file and comments saved on the local host Delete button Deletes the selected file Update button Updates the displayed file list File Type If you select all files dbc dbv the saved search settings files and display settings files are displayed If you select Search settings file dbc only the search settings files are displayed If you select Trend settings file dbv only the display settings files are displayed Open button Opens the settings file selected in the File List When a search settings file is opened the Search window becomes active When a trend settings file is opened the Trend display window becomes active Cancel button Closes the Open dialog box 2 18 IM WX201 01E 2 7 Saving and Loading Search Settings and Results Opening Search Settings from a Network Host Procedure Explanation IM WX201 01E 1 Click Gs
77. st List The a list of files saved on the selected host is displayed 5 Select a file from the list that you wish to load and click Open or double click the file number The Information dialog box opens LI x Ya 1 meza Replace the current trend settings with the selected settings 6 Click the Yes button The trend settings loaded from the trend settings file are displayed Click No to close the Information dialog box Host List The Host List displays the names of any hosts on the network that are running DataBrowser File List Displays the settings files and comments saved on the host selected in the host list Host Name Displays the name ofthe host selected in the host list Update button Updates the host list and file list File Type Open Button and Cancel Button See Opening Trend Settings Files from a Local Host IM WX201 01E 3 8 Converting Data Formats Procedure 1 Open the waveform display screen and display the waveforms of the data you wish to convert 2 Select a range to convert using the cursors if no cursors are displayed all data will be converted Click GG in the waveform display screen toolbar The Data Conversion dialog box opens 4 Data Conversion j xj Conversion Type ren tet Ems kort Slept the check box of Start 450 2004 1203 15 36 46 000 type to turn it ON End ett 20044 205 15 44 22 000 step Setting I write Measured point of the following channel OH CHO Select
78. t Print Preview from the menu bar meals CHL Next Pace Prev Pace Two Pace Zoomi ZoomOut Glose IM WX201 01E 3 27 MOPUIM Aeldsig pudij au jo uougiodo H 3 9 3 28 Printing Data Explanation You can print cursor values and statistics along with waveforms from the trend display screen To print cursor values and waveforms open the Cursor Value dialog box before printing To print statistics open the Statistics dialog box before printing To print cursor values and statistics open both dialog boxes before printing Print Range Choose from Between Cursors and All Selecting Between Cursors prints the waveforms in the cursor range displayed on the trend display screen on a single page Specifying Colors You can select black white print or color print Print Title Enter a title to be printed at the top of the paper IM WX201 01E Chapter A Troubleshooting 4 1 Error Messages and Corrective Actions A message such as an error message may appear during operation The following describes the meanings of the messages and their corrective actions Code Description Corrective Action E0002 Insufficient memory Please close at once Exit all other software programs and restart the OS E0004 Invalid license number Reinstall the software Please reinstall E0101 Please open from the DataBrowser This software cannot be opened by itself Start it from the DataBrowser E4948 Could not initialize commun
79. t to save all the points to a single file the file will exceed the allowable number of rows in Excel or Lotus 1 2 3 making the file unloadable The Automatic Division function automatically creates multiple files that are within the row number limit of Excel and Lotus 1 2 3 The names of the divided files are the original file name plus an appended sequence number File name format file name extension where is a four digit number Ex Output 0003 xIs Excel row limit 65536 Lotus 1 2 3 row limit 8192 Automatic division is not available for conversion to text format 3 26 IM WX201 01E 3 9 Printing Data Printing Procedure 1 Open the waveform display screen 2 Click n the Print button on the toolbar or choose File gt Print from the menu bar The Printout settings dialog box opens Printout Settings Print Range Ce Between Cursors C All Color Ge BlackiWhite Color Enter a comment Print Title to be printed Cancel of up to 255 alphanumeric characters 3 Selecta print range and color and enter a print title Click the OK button The Print dialog box opens Properties Status Type Where Comment TC Det to file Print range Copies Number of copies hi Ge al C Pages bom bo pE E bk Collate Selection Cancel 4 Click the OK button Viewing a Print Preview Procedure 1 Open the trend display screen 2 Choose File g
80. terms and conditions for the Third Party Software which differ from this Agreement the special terms and conditions separately provided by Yokogawa shall prevail over this Agreement Some software may be licensed to you directly by Supplier 2 7 The Software Product may contain open source software OSS for which the special terms and conditions separately provided by Yokogawa shall take precedence over this Agreement 3 Restrictions on Application 3 1 Unless otherwise agreed in writing between you and Yokogawa the Software Product is not intended designed produced or licensed for use in relation to aircraft operation or control ship navigation or marine equipment control or ground facility or device for support of the aforesaid operation or control or for use in relation to rail facility nuclear related facility radiation related equipment or medical equipment or facility or under any other circumstances which may require high safety standards 3 2 Ifthe Software Product is used for the abovementioned purposes neither Yokogawa nor Supplier assumes liability for any claim or damage arising from the said use and you shall indemnify and hold Yokogawa Supplier their affiliates subcontractors officers directors employees and agents harmless from any liability or damage whatsoever including any court costs and attorney s fees arising out of or related to the said use 4 Limited Warranty 4 1 The Software Product shall be provided to yo
81. the active channel in the trend display screen as well Moving Cursors You can move the cursor positions on the trend display using the Up and Down buttons Note e The cursors used to display cursor values and those used to specify the interval for statistical computation over an area are the same e The Cursor Readout dialog box and opens The Computation Results dialog box can be displayed at the same time e If you click a different group in the Trend display screen with the Cursor Readout dialog box open the Cursor Readout dialog box displays the cursor values of the selected group e You can change the cursor positions in the trend display screen while the Cursor Readout dialog box is open Deleting Cursors Click the PR button Erase Cursor button on the Trend display toolbar The cursors are cleared as well as the cursor values displayed in the Cursor Readout dialog box 3 18 IM WX201 01E 3 6 Explanation IM WX201 01E Displaying Computed Results Statistics 1 Inthe waveform display screen click the tab of the group on which you wish to perform statistical computation over an area 2 Click the start point of the computation area in the waveform display area then drag the cursor to define the area and end point use the cursor in the same manner as in section 3 5 iDisplaying Cursor Values 3 Click the Statistics button on the toolbar The Statistics dialog box opens H Statistics a x Channel Min Max PP
82. tle Any titles given to the found files Comment Any comments included with the files Host Name Folder ID The host name and folder ID of the found files Note e Data files are listed in the order in which their hosts were registered e If multiple titles and comments exist only the first title or comment is displayed 2 12 IM WX201 01E 2 5 Displaying Search Results Specifying Pages One hundred search results are displayed on a single page If several pages are generated you can access other pages by clicking the arrow buttons in the upper right of the Search results area Open button Opens previously saved search results files See section 2 6 Save button Saves the currently displayed search results See section 2 6 Sort Function You can sort the search results by various items When you click a column title in the search results display the Sort Status dialog box appears and the results are sorted according to the information in that column Sort Status xj Sorting zm Cancel If you click the Stop button during the sort the items are restored to their original order Resize button e Clicking this button widens the search results area to its maximum width Click the Resize button again to restore the window to its original size e You can also drag the button to the right to size the window manually Unless the area is already at its maximum width Narrowing the Search Results
83. to the updates and upgrades of the Software Product which may be provided by Yokogawa Software Product DAQWORx It is limited to each software that you bought 2 Grant of License 2 1 Subject to the terms and conditions of this Agreement Yokogawa hereby grants to you a non exclusive and non transferable right to use the Software Product on a single or the following specified number of computer s and solely for your internal operation use in consideration of full payment by you to Yokogawa of the license fee separately agreed upon Granted number of License 1 one 2 2 Unless otherwise agreed or provided by Yokogawa in writing the following acts are prohibited a to reproduce the Software Product except for one archival copy for backup purpose which shall be maintained with due care subject to this Agreement b to sell lease distribute transfer pledge sublicense make available via the network or otherwise convey the Software Product or the license granted herein to any other person or entity c to use the Software Product on any unauthorized computer via the network d to cause permit or attempt to dump disassemble decompile reverse engineer or otherwise translate or reproduce the Software Product into source code or other human readable format or to revise or translate the Software Product into other language and change it to other formats than that in which Yokogawa provided e to cause permit or attempt to remove any co
84. tton Deletes the selected search settings file Update button Updates the displayed search results file list File Name Enter the name of the file you wish to save An extension is automatically added Comment Enter comments to be saved with the file Up to 255 alphanumeric characters can be entered Save button Saves the settings file under the specified file name on the local host Note After saving a search settings file the saved file name and comment appears in the text box the next time you open the Save search settings dialog box these items are blank if no settings have been saved previously or when starting up the software Also when you select a file in the Save search settings dialog box the file and comment are displayed in the input boxes at the bottom of the window This allows you to conveniently overwrite settings IM WX201 01E 2 17 MOPUIM y2129S Veq eu JO uoneiado 2 7 Saving and Loading Search Settings and Results Opening Search Settings from a Local Host Procedure 1 Click Gs on the toolbar or choose File gt Open from the menu bar The Open dialog box is displayed One E ees O belete button Local Host Hosts on network File List t r Update button File Mame Comment 1 i AOOMu0UT OC search conditions _Feb 07 2005 H i DAGLOGGERO dhc search conditions _Feb 08 2005 A 0100 01 dbc search conditions _Feb 0r 200 4 i latest db search conditiion
85. u on an as is basis at the time of delivery and except for physical damage to the recording medium containing the Software Product Yokogawa and Supplier shall disclaim all of the warranties whatsoever express or implied and all liabilities therefrom If any physical defect is found on the recording medium not later than twelve 12 months from delivery Yokogawa shall replace such defective medium free of charge provided that the defective medium shall be returned to the service office designated by Yokogawa at your expense within the said twelve 12 months THIS LIMITED WARRANTY PROVIDED IN THIS CLAUSE IS IN LIEU OF ALL OTHER WARRANTIES OF ANY KIND WHATSOEVER AND YOKOGAWA HEREBY DISCLAIMS ALL OTHER WARRANTIES RELATING TO THE SOFTWARE PRODUCT WHETHER EXPRESSED OR IMPLIED INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR ANY PARTICULAR PURPOSE NON INFRINGEMENT QUALITY FUNCTIONALITY APPROPRIATENESS ACCURACY RELIABILITY AND RECENCY IN NO EVENT SHALL YOKOGAWA WARRANT THAT THERE IS NO INCONSISTENCY OR INTERFERENCE BETWEEN THE SOFTWARE PRODUCT AND OTHER SOFTWARE NOR SHALL BE LIABLE THEREFOR The warranty provisions of the applicable law are expressly excluded to the extent permitted 4 2 Atthe sole discretion of Yokogawa Yokogawa may upgrade the Software Product to the new version number Upgrade and make it available to you at your expense or free of charge as Yokogawa deems fit In no event shall Yokogawa be oblig
86. ults file under the specified file name on the local host 2 20 IM WX201 01E 2 7 Saving and Loading Search Settings and Results Opening Search Results from a Local Host Procedure Explanation IM WX201 01E 7 Click the Open button in Search results area or choose File gt Open the search results from the menu bar The Open dialog box is displayed Josi Delete button Open Local Host Hosts ii SC il File List Update button File Name Comment 1 Addhiutti 4001 SearchResutts_Feb 06 2005 A AddTriggeri A001 SearchResutts_Feb 06 2005 2 DASLOGGER 4001 SearchResutts_Feb 08 2005 4 Ox 100 4001 searchResults_Feb 08 2005 5S Ms100 4001 searchResults_Feb 08 2005 Drag to change the column width Double click a number to open the file Open Cancel Select a file and click Open or double click the file number The Information dialog box opens Information 2 3 Mag Replace the current search result with the selected result Click the Yes button The search results loaded from the search results file are displayed Click No to close the Information dialog box File List Displays the name of the search results file and comments saved on the local host Delete button Deletes the selected file Update button Updates the displayed file list Open button Opens the search results file selected in the File List Cancel button Closes the Open dialo
87. um SP1 32 bit and 64 bit editions e Windows 7 Professional SP1 32 bit and 64 bit editions The language displayed by the software under different language versions of the OS are as follows OS Language Software Language Japanese Japanese Other English Note This manual uses screens displayed on Windows 2000 to describe the procedures PC A PC that runs one of the OS above and that meets the following CPU and memory requirements When Using Windows 2000 or Windows XP Pentium 4 1 6 GHz or faster Intel x64 or x86 processor 512 MB or more of memory When Using Windows Vista Pentium 4 3 GHz or faster Intel x64 or x86 processor 2 GB or more of memory When Using Windows 7 32 bit edition Intel Pentium 4 3 GHz or faster x64 or x86 processor 2 GB or more of memory 64 bit edition Intel x64 processor that is equivalent to Intel Pentium 4 3 GHz or faster 2 GB or more of memory Note The specifications above are for a desktop PC not a notebook PC Hard Disk Free disk space 200 MB or more CD ROM Drive for Use during Installation Monitor A video card that is recommended for the OS and a display that is supported by the OS has a resolution of 1024x768 or higher and that can show 65 536 colors 16 bit high color or more Printer and Mouse A printer and mouse supported by the OS Ethernet Port An Ethernet compatible port 10BASE T or 100BASE TX 1 3 Jasmoige eg ou Buisn a10jog E 1 3 Starting and Exiti
88. uted Results Gtattetcel 3 19 3 7 Saving and Loading Trend Gettmges 3 20 Saving Data Trend Settings acasescigccsictcidectn lea deicnadecint decisedenedcccdaine iacte decbadeetindeiidenstienteddbadectecusts 3 20 Opening Trend Settings from a Local Host 3 21 Opening Trend Settings indstop from a Network Hoer 3 22 Sie COnvening Data Geld 3 23 99 Prnung Dala AAA WA 3 27 PMN ele E 3 27 MEY Mee FG WY AI 3 27 Troubleshooting 4 1 Error Messages and Corrective Actions ccccccseseseceeceeeeeeeceeeeeeseeeeeeeeeeesssaeeseeeeeeeeeeeeeaaas 4 1 Search Folder Registration ccs crscescccixssintedatienlacanbebeneccedeoutolnsaed eet eege eege 4 1 Executing SOA e 4 1 Saving and Loading Settings and Search Hesults 4 2 Saving and Loading Settings and Search Hesults rn nnrrreensrrnrnrrrrrrrenen 4 2 IM WX201 01E Chapter 1 Before Using the DataBrowser 1 1 Overview of DataBrowser Functional Overview DataBrowser Is a software application providing data file searching and display functions It allows you to search for and display data files saved by Yokogawa recorders and data acquisition software programs from a local or network host Note Hosts on the network must be running DataBrowser Data Search Function Search Window Five categories of search conditions are available making entry of criteria simple Also you can select multiple search conditions to refine your searches 1 Time You can search for files of a specific year month
89. within results Click to the right of each item to change the tabs on the right 4 Select the File Name or Extension option 5 Enter the file name or extension to use as a search criterion Explanation File name specification allows you to search for files whose names contain the specified keyword or extension File Name You can enter an entire file name or portion thereof Extension You can enter an entire file name extension or portion thereof Note To specify multiple files names or extensions use a space as a delimiter Note that wildcards etc are not allowed IM WX201 01E 2 7 2 3 Specifying Search Conditions Specifying Data Types Procedure 1 Specify a search folder See section 2 2 2 Select the Data Type check box in the Search conditions area 3 Click the Data Type tab or click the word Data Type to the right of the check box The Data Type tab is displayed Check box Search conditions _ 3 z S s a Time FileName Data Type Keywords Serial No Time i DAGLOGGER AddMutti C File Name ji CL AddTrigger C mx100 Fidata Type M bx100 200 mv100 200 orane C cx1000 2000 C Fx100 _ Keywords E Serial No bel Search subfolders Search Search within results Click to the right of each item to change the tabs on the right 4 Select the types of data to search for Explanation Data type specification allows you to search for files of the specified
90. y range is set as 0 at the bottom and 100 at the top The values in the Zone Min and Max columns represent the lower 0 9 and upper 1 100 ends of the trend display range Waveform Display Screen fone Min hax 25 fis T 100 Setting Trip Points You can display a trip line to indicate a particular value of interest trip point in the trend display area Two trip points trip 1 is red trip 2 is blue can be set for each waveform By selecting and clearing the check buttons in the Trip 1 and Trip 2 columns you can select whether to display the corresponding trip points in the Trend display screen Trip 1 value Trip 2 value Waveform Display Screen Trip line ON OFF MOPUIM ejds g pu L au jo uougiodo H 3 3 Settings in the Channel Setup Screens Channel Display Colors You can assign colors to channels displayed in the trend display screen Click the colored part to open the Color Settings dialog box Basic colors 11 SEBO Define Custom Colors gt gt SR Showing Channel Details You can view detailed information about a channel selected in the channel setup screens e Click E in the channel setup screen toolbar The Channel Information dialog box opens Be Channel Information Group Name Groupp Name of currently displayed group No EN Number assigned within groups Channel CHOODOH Channel Tag No Malo 01 Tag number reng identifiers Tag Comment WXLOGGER 01 Tag comment Unit
91. y that the requirements of this Agreement are being met 8 2 Even after license being granted under this Agreement should there be any change in circumstances or environment of use which was not foreseen at the time of delivery and in Yokogawa s reasonable opinion is not appropriate for using the Software Product or if Yokogawa otherwise reasonably believes it is too inappropriate for you to continue using the Software Product Yokogawa may suspend or withhold the license provided hereunder 9 Assignment If you transfer or assign the Software Product to a third party you shall expressly present this Agreement to the assignee to ensure that the assignee comply with this Agreement transfer all copies and whole part of the Software Product to the assignee and shall delete any and all copy of the Software Product in your possession irretrievably This Agreement shall inure to the benefit of and shall be binding on the assignees and successors of the parties 10 Termination Yokogawa shall have the right to terminate this Agreement with immediate effect upon notice to you if you breach any of the terms and conditions hereof Upon termination of this Agreement you shall promptly cease using the Software Product and in accordance with sub clause 2 5 return or irretrievably delete all copies of the Software Product certifying the same in writing In this case the license fee paid by you for the Software Product shall not be refunded Clauses 2 4 and 2 5
92. yed Displaying Waveforms of Different Intervals Data of differing measurement intervals can be displayed in the same waveform display screen Measurement Interval of Displayed Waveforms When the measurement intervals differ the greatest common factor of the measurement intervals of the channels assigned to the displayed groups is used as the minimum interval unit for displaying all of the waveforms In the figure below since the intervals for the three channels are 1 s 500 ms and 250 ms respectively 250 ms is used as the interval when all channels are displayed together Greatest common factor Displaying Waveforms of Intervals Greater Than the Minimum Unit If a channel s interval is longer than the minimum unit interval data values that are not measured points are displayed at the value of the points directly thereafter Measured point Minimum unit interval waveform Longer than the minimum unit interval waveform Same value Same value 7 Same value Same value Measured point Measured point Minimum unit display interval _ _ _ _ __ __ _ _ _ _ _ gt The figure below shows a 100 ms and 1 s interval waveform The waveform with the long interval is displayed in stages Minimum Unit Interval for Linked Groups The greatest common factor of the measurement interval of all channels registered to all groups belonging to the linked group is used as the minimum unit interv
93. ys the results of the search The number to the left of the slash indicates the number of files that matched the criteria and the number to the right represents the total number of files searched The number of files that can be searched from a single registered folder ID is sixty thousand Once that limit is reached the search stops Error button If an error occurs the button becomes K You can click the Error button to display the contents of the error message Error Displays the error number and message Total Displays the total number of files found and searched Stop button Stops the search Once a search is stopped the results obtained in progress are displayed Close button Closes the Search status dialog box When the search stops the Stop button changes to the Close button MOPUIM y2129S Veq eu JO uoneiado 2 5 Displaying Search Results Displaying the Search Status Procedure 1 When a registered folder is searched with specified conditions the search results are displayed in the Search results area Registering Search Folders section 2 2 Specifying Search Conditions section 2 3 Executing the Search section 2 4 Display previous page Display next page Display first page Display last page Search results ala L File Details 44 gt E Host Name Folder ID CPCO01 13666 01 Folder001 E Channels 24 E File Name File Name DAGLOGGER 200001 03 0006 mid DAGLOGGER 200001 03 0007 mld 20
Download Pdf Manuals
Related Search
Related Contents
Grundträger Roof Rack Barres de toit Soporte básico Supporto base IBM RackSwitch G8052 TEFAL BM6001V0 Instruction Manual MTM800 Enhanced TETRA-Mobilfunkgerät Installationshandbuch Télécharger le PDF Liebert RDU-S User`s Manual USER`S INFORMATION MANUAL - Alpine Home Air Products 5-Language European Translator - Franklin Electronic Publishers, Inc. Copyright © All rights reserved.