Home
77-021 - 2helpU
Contents
1. Press power key to power laser ON Press and hold for 3 seconds to power laser OFF Press power key to toggle through available laser modes horizontal only vertical only both horizontal and vertical horizontal and vertical with 90 vertical reference beam all on with self leveling disabled Laser mode LEDs light red and or green to indicate current laser mode LED code is shown on keyboard Power key is functional in both the locked and unlocked switch position Press pulse mode key to toggle between pulse mode ON and OFF Indicator LED lights green when on Pulse mode allows use with a laser detector Laser beam s blink to indicate the laser unit is out of the working range for laser modes 1 4 when self leveling function is enabled Reposition laser unit to be more level K 9 8 Low battery LED blinks red to indicate when battery power is low Replace batteries Low Battery LED Universal Mounting Bracket J E 1 Laser unit fits into mounting bracket Pins in Pins on laser unit laser unit fit into alignment holes in bracket Standard Mount for 9 8 in Optional Tripod Mounting SS Alignment holes in bracket base 2 5 8 11 thread mount available for optional accessories optional accessories f 3 Key hole slot for wall hanging or for use with Optional Mounting Hardware 771 021 Applications eee 1 Plumb Using the vertical laser beam establis
2. STANLEY 3 Beam Self Leveling Cross Line Laser a m 77 021 Please read these instructions before operating the product Self Leveling 00000000009000008000090 S Contents _ _ _ ie Ze oi 4 a 6 A Safety Safety Product Description Specifications Operating Instructions Calibration Maintenance and Care Warranty kn A User Safety Carefully read the Safety Instructions and User Manual before using this product The person responsible for the instrument must ensure that all users understand and adhere to these instructions Retain this manual for future reference IMPORTANT The following labels are on your laser tool for your convenience and safety They indicate where the laser light is emitted by the level ALWAYS BE AWARE of their location when using the level LASER RADIATION DO NOT STARE INTO BEAM OR VIEW DIRECTLY WITH OPTICAL INSTRUMENTS CLASS 1 LASER PRODUCT MAX OUTPUT lt 1 mW 630 670 nm EN 60825 1 771 021 DO NOT remove any warning label s on the housing This instrument must only be used for leveling and layout tasks as outlined in this manual ALWAYS make sure that any bystanders in the vicinity of use are made aware of the dangers of looking directly into the laser tool DO NOT use in combination with other optical instruments Do not modify the instrument or make manipulations or use in other applications th
3. 3 Quick Calibration Access Hole 4 Window for 90 Vertical Reference Beam Laser Horizontal Vertical Accurracy lt 1 5mm 3m_ lt 1 16 in 10 ft 5 Quick Calibration Access Hole Working Range Self Leveling to 5 Working Distance lt 10m_ lt 30ft with Laser Detector lt 30m lt 100 ft 6 Battery Compartment Cover Laser Class Class 1 Laser Wavelength 635 nm 5 nm Operating Time 15h Power Voltage 4 5 V 7 Transport Lock Power Supply 3 x AA Batteries Alkaline 8 Laser Warning Label IP Rating IP54 Operating Temperature Range 10 C to 40 C 14 F to 104 F Universal Mounting Bracket Storage Temperature Range 20 C to 60 C 4 F to 140 F Weight without Base and Batteries 4909 17 3072 1 Keyhole Slots Size 86 mm x 147 5mm 33 8 in x5 3 4 in 2 Alignment Holes for Laser Unit 3 5 8 11 Thread Mount 6 k 77 721 7o 7 Operating Instructions Battery Installation Removal 1 Turn laser unit to back Open battery compartment cover by pressing and sliding out 2 Install Remove batteries Orient batteries correctly when placing into laser unit 3 Close and lock battery compartment cover by sliding in until securely closed Laser Unit p Locked a Laser ON OFF Laser Mode LEDs 77 021 Transport lock in locked position Self leveling function is disabled Transport lock in unlocked position Self leveling function is enabled
4. Calculate the difference between distances D and D to get D and distances D and D to get D 4 6 Calculate the maximum allowed offset distance and compare to the difference of D and D as shown in the equation If Max the sum is not less than or equal to the calculated maximum offset distance the unit must be returned to your Stanley Distributor Maximum Offset Distance 0 33 Ty x D m 2 x D m 0 004 x D ft 2 x D ft Compare D D lt Max Example D 10 m D 0 5m D 30 75 mm D 29 mm D 30 mm D 29 75 mm D 30 75 mm 30 mm 0 75 mm D 29mm 29 75 mm 0 75 mm 0 335 x 10m 2 x 05m 2 97 mm maximum allowed offset distance 0 75 mm 0 75 mm 1 5 mm 1 5mm lt 2 97 mm TRUE unit is within calibration Horizontal Beam Accuracy 1 Place laser unit as shown with laser ON Aim vertical beam to first corner or reference point Measure out half of the distance D and mark point P ma SO Vertical Beam Accuracy 2 Rotate laser unit to other corner or l 1 Measure the height of a door jamb or reference point reference point to get distance D Place laser unit as shown with laser ON Aim vertical beam towards door jamb or reference point Mark points P P and P as shown 3 Measure the vertical distances between F and the horizontal beam from the 2nd location 2 Move laser unit to opposite si
5. batteries DO NOT mix old and new batteries Replace all of them at the same time with new batteries of the same brand and type DO NOT mix battery chemistries DO NOT dispose of batteries in fire ALWAYS keep batteries out of reach of children ALWAYS remove batteries if the device will not be used for several months NOTE Ensure that the correct batteries as recommended are used NOTE Ensure the batteries are inserted in the correct manner with the correct polarity H PLEASE RECYCLE in line with local provisions for the collection and disposal of electrical and electronic waste under the WEEE Directive End of Life DO NOT dispose of this product with household waste ALWAYS dispose of batteries per local code 71 021 Declaration of Conformity The Stanley Works declares that the CE Mark has been applied to this product in accordance with the CE Marking Directive 93 68 EEC This product conforms with EN60825 1 2007 For further details please refer to www stanleyworks com A S EN 60825 1 ROHS Compliant Product Description Package Contents i 2 2 4 0 6 77 021 Laser Unit Universal Mounting Bracket Laser Target Carrying Case Batteries 3 x AA User Manual Product Overview e oo Specifications Laser Unit Leveling Accuracy lt 3mm 9m lt 1 8in 30 ft 1 Keyboard 2 Window for Cross Beam Laser Square Beam Accuracy lt 1 5mm 3m_ lt 1 16 in 10 ft
6. an those described in the manual DO NOT look into the beam with optical aids such as magnifiers binoculars or Telescopes DO NOT stare into the laser beam or direct it towards other persons Make sure the instrument is not set at eye level Eye protection is normally afforded by natural aversion responses such as the blink reflex DO NOT direct the laser beam at other persons ALWAYS turn the laser tool OFF when not in use Leaving the laser tool ON increases the risk of someone inadvertently staring into the laser beam DO NOT operate the laser tool in combustible areas such as in the presence of flammable liquids gases or dust DO NOT disassemble the laser tool There are no user serviceable parts inside Disassembling the laser will void all warranties on the product Do not modify the product in any way Modifying the laser tool may result in hazardous laser radiation exposure DO NOT use this instrument in areas where a risk of explosion is present NOTE Since the laser beam is of the focused type ensure you check the beam s path over a relatively long distance and take all necessary precautions to ensure the beam cannot interfere with other persons 77 021 3 Battery Safety WARNING Batteries can explode or leak and can cause injury or fire To reduce this risk ALWAYS follow all instructions and warnings on the battery label and package DO NOT short any battery terminals DO NOT charge alkaline
7. de of door jamb or reference point and align vertical beam with P and P l Maximum Offset Distance 4 Calculate the maximum allowed offset Maximum Offset Distance mm distance and compare to D If D is ie e ae not less than or equal to the calculated 0 006 x D ft maximum offset distance the unit must be returned to your Stanley Distributor Compare 3 Measure the horizontal distances between D lt Max P and the vertical beam from the 2nd location Example D 5m D 1mm 0 500 x 5m 2 5 mm maximum allowed offset distance Maxi gristi E yee nce 1mm lt 2 5 mm TRUE unit is within calibration 4 Calculate the maximum allowed offset ee na distance and compare to D If D is cian ant 2 ial not less than or equal to the calculated 0 012 x D ft maximum offset distance the unit must be returned to your Stanley Distributor Compare lt Max Example D 2m D 1mm 10m x 2m 2mm maximum allowed offset distance 1mm lt 2mm TRUE unit is within calibration uy ye OA moa K a 90 Vertical Beam Accuracy You will need at least 1 5 m 16 ft of floor space and possibly an assistant for this check 1 Place the laser unit without its mounting bracket on a level floor and turn on all beams mode 4 2 Measure exactly 0 91 m 3 ft out from the center of the laser unit along the vertical beam of the laser cross To easily refer ence the center of the laser un
8. h a vertical reference plane Position the desired object s until they are aligned with the vertical reference plane to ensure object s are plumb Level Using the horizontal laser beam establish a horizontal reference plane Position the desired object s until they are aligned with the horizontal reference plane to ensure object s are level Square Using either the vertical and horizontal laser beams with or without the 90 vertical reference laser beam establish a point where the vertical and horizontal beams cross Position the desired object s until they are aligned with both the vertical and horizontal laser beams to ensure object s are square 4 Pulse Mode Setting laser unit to pulse mode allows use of optional laser detectors 5 Manual Mode Disables self leveling function and allows laser unit to project a rigid laser beam in any orientation 71 021 NOTE The laser unit has been calibrated at the time of manufacturing Periodically check the accuracy of the laser unit to ensure that the calibrated specifications are maintained Level Beam Accuracy 1 Place laser unit as shown with laser ON Mark point P at cross 2 Rotate laser unit 180 and mark point P at cross 3 Move laser unit close to wall and mark point P at cross 4 Rotate laser unit 180 and mark point P at cross 71 021 5 Measure the vertical distance from the floor to each point
9. it start the first measurement against the outer base of the laser unit measure out 0 91 m 3 ft and then subtract 4 3 cm 1 69 in Mark this point P 3 Measure exactly 1 22 m 4 ft out from the center of the instrument along the at 90 vertical reference beam and mark this 1 22 m 4 ft gt point P 4 Measure from point A to point B this distance D should equal 1 52 m 1 2 mm 5 ft 3 64 in If not the unit must be returned to your Stanley Distributor 5 Repeat steps 1 through 4 as needed to recheck the measurements 771 021 Maintenance and Care Laser unit is not waterproof DO NOT allow to get wet Damage to internal circuits may result DO NOT leave laser unit in direct sunlight or expose it to high temperatures The housing and some internal parts are made of plastic and may become deformed at high temperatures DO NOT store the laser unit in a cold environment Moisture may form on interior parts when warming up This moisture could fog up laser windows and cause corrosion of internal circuit boards When working in dusty locations some dirt may collect on the laser window Remove any moisture or dirt with a soft dry cloth DO NOT use aggressive cleaning agents or solvents Store the laser unit in its case when not in use If storing for extended time remove batteries before storage to prevent possible damage to the instrument 7o YS worn OOO One Year Warranty Stanle
10. ore for the calibration of the instrument 2010 The Stanley Works stanley Europe Egide Walschaertsstraat 14 16 Calibration and care are not covered by warranty 2800 Mechelen Belgium Subject to change without notice Issue 1 01 10 WWW STANLEYWORKS COM 8 x 7O
11. y Tools warrants its electronic measuring tools against deficiencies in materials and or workmanship for one year from date of purchase Deficient products will be repaired or replaced at Stanley Tools option if sent together with proof of purchase to Stanley UK Sales Limited Gowerton Road Brackmills Northampton NN4 7BW This Warranty does not cover deficiencies caused by accidental damage wear and tear use other than in accordance with the manufacturer s instructions or repair or alteration of this product not authorised by Stanley Tools Repair or replacement under this Warranty does not affect the expiry date of the Warranty To the extent permitted by law Stanley Tools shall not be liable under this Warranty for indirect or consequential loss resulting from deficiencies in this product This Warranty may not be varied without the authorisation of Stanley Tools This Warranty does not affect the statutory rights of consumer purchasers of this product This Warranty shall be governed by and construed in accordance with the laws of England and Stanley Tools and the purchaser each irrevocably agrees to submit to the exclusive STANLEY jurisdiction of the courts of England over any claim or matter arising under or in connection IMPORTANT NOTE The customer is responsible for the correct use and care of the instrument Moreover the customer is completely responsible for periodically checking the accuracy of the laser unit and theref