DataBand E1T1 Quickstart Guide

image

Contents

1. 5 2 4 Making Connections 5 2 5 Installing DbManager 3 Configuring DataBand E1T1 5 6 3 1 Connecting to DataBand E1T1 7 3 2 Notes on configuring DataBand E1T1 8 3 3 Identifier and Ethernet Settings 8 3 4 ISDN Port Configuration 8 3 5 Clock Sources 8 3 6 Finishing Configuration 8 3 7 More Resources Introduct
2. 2012 Patapsco Designs Ltd DataBand E1T1 Quickstart Guide V3 2 All rights reserved No parts of this work may be reproduced in any form or by any means graphic electronic or mechanical including photocopying recording taping or information storage and retrieval systems without the written permission of the publisher Products that are referred to in this document may be either trademarks and or registered trademarks of the respective owners The publisher and the author make no claim to these trademarks While every precaution has been taken in the preparation of this document the publisher and the author assume no responsibility for errors or omissions or for damages resulting from the use of information contained in this document or from the use of programs and source code that may accompany it In no event shall the publisher and the author be liable for any loss of profit or any other commercial damage caused or alleged to have been caused directly or indirectly by this document Printed March 2012 in UK Patapsco has recently been acquired by Communications Systems Inc CSI and is now a part of Transition Networks Inc a subsidiary of CSI The high quality reliable Transition Networks brand of products is now combined with the world class portfolio of telecommunications and data communications products from Patapsco Communications You can be assured that the same quality and support from both organizations will continue Plea
3. DataBand E1T1 are connected to the same LAN management is possible using TCP IP All Patapsco products use the default IP settings IP Address 192 168 0 1 Subnet Mask 255 255 0 0 Gateway 0 0 0 0 To configure DbManager to access DataBand E1T1 using TCP IP please follow these steps 1 Select View Properties Terminal Device IP Addresses from the DbMgr toolbar 2 192 168 0 1 should already be configured If using another IP address add it to the list using the Add button 3 Click OK OK 4 Select the Devices in World window and double click the Device node 5 The Connected to Device window should appear showing the front and rear panels of DataBand E1T1 The Device node can be made to connect to other IP addresses configured in the Device IP Addresses list by right clicking the node selecting Properties and choosing an IP address from the IP List Info TCP IP management requires TCP port 3001 dec to be open between the management PC and DataBand E1T1 Any switches hubs or routers must be configured to allow communication on this port in order to manage DataBand E1T1 via TCP IP Configuring DataBand E1T1 7 2012 Patapsco Designs Ltd A successful management connection will open up the Connected to Device window 3 2 Notes on configuring DataBand E1T1 Uploading Changes to config can be made on each window and saved using the OK key when exiting each window When happy with the configuration it must be uploaded to
4. DataBand E1T1 for the new settings to come into effect To upload go to File Upload or press the Upload button on the config window and wait until the progress bar completes Saving Files Configuration files can be saved in order to backup settings or copy settings across to another unit Once configuration has been uploaded go to File Save File and choose a location to save the file to The file extension of any saved config files is dbc Loading Files Once connected to a unit an existing configuration file can be loaded to the device Go to File Open File and navigate to the saved file Click Open Now the file must be uploaded to DataBand E1T1 Go to File Upload or press the Upload button on the config window and wait until the progress bar completes Warning When loading existing configuration files to a unit please ensure that the correct configuration files are used for the unit type in use DataBand E1T1 configuration files are not compatible with other Patapsco platforms DataBand E1T1 Quickstart Guide 8 2012 Patapsco Designs Ltd 3 3 Identifier and Ethernet Settings This menu controls the IP Address Subnet Mask Default Gateway and Identifier Enter a unique Identifier and IP settings for the unit These features are all fully explained in the DataBand E1T1 User Manual on the DbManager Installation Disk 3 4 ISDN Port Configuration Set the TDM ports to E1 or T1 mode T1 ports have options relating to the T1 Lin
5. 12 DB9S Pin Function Pin 1 Rx 3 2 Tx 2 3 Gnd 5 IEC Mains Cable Connects DataBand E1T1 to the mains supply 2 3 Optional Accessories The following items can be ordered from Patapsco or will be supplied with some units depending on the nature of the device ISDN Cables Cables to connect the Patapsco device to a CPE or network Please see the full manual for cable specs on all Patapsco cables Rack Mounting Kit All Patapsco units can be monuted in a 19 rack using this kit Getting Started 5 2012 Patapsco Designs Ltd 2 4 Making Connections First connect the ISDN cables to DataBand E1T1 followed by the Terminal Port management cable if required LAN Port cable and lastly the Mains cable If the unit has a DC power supply connection use the screw terminals to connect the DC power source Warning The 48VDC power terminals are marked 0V 48V and GND Patapsco 48VDC products are designed for use with negative voltage DC supplies and therefore expect the positive voltage to be connected to the 0V terminal and the negative connected to 48V Please be sure about the polarity of this connection before connecting power to the terminals Units which have a positive 24VDC power source will be marked 24VDC 0V and GND respectively Please ensure that the positive connection is made on the 24VDC terminal 2 5 Installing DbManager DbManager is required in order to monitor and manage Patapsco devices Mana
6. amp Manuals folder on the DbManager installation disk Please consult these manuals for more detailed information on any aspect of using Patapsco products All documentation can also be obtained by registering at the Patapsco website http www patapsco co uk Top_Level LogIn_Register asp For help with a specific problem please click on the On Line Help icon on the website or email a request to support patapsco co uk
7. e Code and Framing type Please consult the documentation of the connected CPE if unsure of the correct settings to use There are two LEDs for each TDM port and the LED states are as follows Top LED on Layer 1 and 2 established Bottom LED on Channels active on interface 3 5 Clock Sources DataBand E1T1 must be configured to either receive clock from an ISDN interface a connection to another DataBand E1T1 or generate clock internally Different priorities can be set for each port so if one port is unavailable DataBand E1T1 will clock from the next available port in the Clock Source hierarchy Enter a digit to mark the priority of each ISDN port and the internal clock 0 will denote the highest priority Clock Source and 19 will denote the lowest Ports which are not to be used for clocking can have their values left at 19 Warning Clock Sources must be configured correctly to ensure error free operation when DataBand E1T1 is connected to any other clock locked system or network Please consult the full DataBand E1T1 manual if unsure how to configure Clock Sources 3 6 Finishing Configuration Note Please remember to Upload when configuration of DataBand E1T1 is complete To upload go to File Upload or press the Upload button on the config window and wait until the progress bar completes 3 7 More Resources All Patapsco products and the DbManager application have their own User Manuals which can be found in the Documents
8. gement can be made using the Terminal serial port or using TCP IP over a LAN or WAN DbManager is installed using the CD provided with Patapsco equipment 1 Insert the DbManager Installation Disk into the drive of the PC which will be used for management of DataBand E1T1 2 InstallShield Wizard will start up Follow the steps to install DbManager 3 Serial Number Enter the Serial Number on the case of the DbMgr Disk Info DbManager is supplied as a Lite version by default This allows configuration and monitoring of devices but only allows configuration of a single device node and a single user account To use DbManager in Lite mode do not enter a serial number during installation Please see the full DbManager User Manual for more information on configuring and using DbManager Warning If an older version of DbManager is already installed on the management PC it is necessary to update to the version supplied on the new DbManager CD This can be done by consulting the Upgrade folder on the DbManager CD The readme txt file explains how to upgrade to the new DbManager without reinstalling the program 3 Configuring DataBand E1T1 Follow these steps to connect to DataBand E1T1 with DbManager and configure the unit for use Configuration of DataBand E1T1 is carried out by setting up DbManager to make a management connection and then setting up the elements of DataBand E1T1 in this order Identifier and Ethernet settin
9. gs The IP address settings and unique Identifier of the unit ISDN Port Settings Settings for the ISDN ports Clock Sources configure which interface DataBand E1T1 is to take synchronisation clock from DataBand E1T1 Quickstart Guide 6 2012 Patapsco Designs Ltd 3 1 Connecting to DataBand E1T1 1 Start up the DbManager Application 2 Login as Super User no password required 3 Four windows will be displayed Map A network map showing Nodes and Links between Patapsco devices Terminal A view of the communications between DbMgr and DataBand E1T1 Event History All events which occur while connected to DataBand E1T1 Outstanding Events Current events 4 Select View Properties Terminal from the DbMgr toolbar 5 Choose the COM port which is in use Leave the Serial Port Rate at the default setting of 19200bps Click OK 6 Select the Devices in World window and double click the Device node 7 The Connected to Device window should appear showing the front and rear panels of DataBand E1T1 If it does not check the COM port settings and re try Warning If management via the Terminal port is not possible it could be that the management PC has another application running which uses the COM ports of the PC Even when some programs which use the COM ports are closed down other programs cannot access the COM ports Rebooting the PC is required in order to release the COM ports so that DbManager can use them If the PC and
10. ion 3 2012 Patapsco Designs Ltd 1 Introduction This document is a basic guide for configuring a new Patapsco DataBand E1T1 A full User Manual for configuring all settings on the unit is supplied on the DbManager Installation Disk Patapsco offers an optional Pre Configuration Service and optional Telephone Support Agreements at minimal cost Information on these options can be found in the Support document on the DbManager installation disk 1 1 Transition Networks Patapsco Patapsco DataBand products allow cross connectivity of E1 and T1 ports and timeslots between any source and destination connected to the unit Conversion of E1 to T1 and vice versa is catered for as well as conversion between A law and law voice calls while the DataBand E1T1 range allows simple conversion between the E1 and T1 protocols The EV device allows conversion between V 35 and E1 T1 protocols 1 2 Safety warnings Caution Danger of electric shock The device may be connected to mains voltages Switch to power off state before working on the device Caution Danger of electrostatic discharge Electronic components are sensitive to electrostatic discharges that might damage the device Protect the device from electrostatic discharges by wearing an electrostatic wristband Caution Interruption of data transmission Data transmission will be interrupted during any work on the transmission line and or deactivation of the power supply Make sure that tha
11. se contact either Transition Networks or Patapsco Communications for sales support and product information Patapsco Communications The Passfield Oak Passfield Near Liphook Hampshire GU30 7RL UK Tel 44 0 1428 752900 Fax 44 0 1428 752901 Email info patapsco co uk Web Site www patapsco co uk Transition Networks 10900 Red Circle Drive Minnetonka MN 55343 USA Tel 952 941 7600 or 1 800 526 9267 Fax 952 941 2322 Email info transition com Web Site www transition com DataBand E1T1 Quickstart Guide 2 2012 Patapsco Designs Ltd Table of Contents 1 Introduction 3 3 1 1 Transition Networks Patapsco 3 1 2 Safety warnings 2 Getting Started 3 4 2 1 Rack Mounting Instructions 4 2 2 Accessories 4 2 3 Optional Accessories
12. t 4 washer 4 Rack Mount Screw 4 All Patapsco units can be mounted in a standard 19 rack housing To allow units to fit into a 19 rack a Rack Mounting Kit must be purchased for the unit s There are various rack mounting options depending on the size of the unit ordered The following guide will explain how to use the Rack Mounting Kit with Patapsco units 1 Remove the four short screws near the front or rear panel on the left and right hand sides of the Patapsco unit The unit can be mounted with the front panel facing forward or with the ports facing forward as required 2 Fit one of the L Brackets to the side of the unit The four small fixing holes allow the unit to protrude forward or sit further back depending on the desired position of the unit The bracket may also face forwards or backwards depending on the desired position of the unit 3 Fix the L Bracket in place using the Long Patapsco case screws 4 Fix the second L Bracket to the other side of the case in the same way 5 Put the Rack Mount screws through the Rack Mount washers 6 Offer the unit up to the rack and fix it in place using the Rack Mount Screws and Rack Mount cage nuts 2 2 Accessories The following accessories are supplied with all Patapsco units Item Description DbManager CD Installable DbManager application technical documents and manuals Controller Cable Management cable Connects to DataBand E1T1 sTerminal port Cable Spec RJ
13. t any work will only be carried out on inactive lines without data transmission or during quiet times to reduce interference to live systems Caution Danger of damage to devices or service interruption Access by unauthorized third persons may cause damage to devices and or interrupt services Make sure that subracks are only installed in lockable locations Caution Danger of overvoltage During faults dangerous unprotected voltages may be present Ensure sufficient grounding of the housings i e by connecting the grounding contact Safety requirements are not fulfilled unless this equipment is connected to a wall socket outlet with a protective earth PE contact The power cord used to connect this equipment must be HAR marked and fitted with an IEC320 connector and an ASTA approved moulded plug There are no user serviceable parts in this equipment All servicing and repair tasks must be undertaken by qualified service personnel Isolation from mains power is achieved by the removal of the main power cord 2 Getting Started This section will describe how to make the physical connections between DataBand E1T1 and the other system devices and install the Patapsco management application DbManager DataBand E1T1 Quickstart Guide 4 2012 Patapsco Designs Ltd 2 1 Rack Mounting Instructions The Rack Mounting Kit is comprised of the following Photo Description Quantity L Bracket 2 Long Patapsco case screw 4 Cage Nu