Home
        MLP100 User`s Manual
         Contents
1.        Software Installation      Continue Anyway      STOP Installation         Chapter 1  INTRODUCTION        4  Click the  Continue Anyway  button    gt  gt The installation program then starts up  and after it is completed  the follow   ing screen appears     Yamatake USB Loader Cable Driver Installer    Congratulations     The drivers were successfully installed on this computer     You can now connect your device to this computer  IF your device  came with instructions  please read them first        Driver Name Status  y       Yamatake  YCsIp  USB     Ready to use                 5  Click  Finish  button to complete the installation     2  Insert the USB loader cable into the USB port    gt  gt When Windows recognizes the USB cable  the notification shown below  appears on the task tray and the driver installation wizard appears     LON    i  Found New Hardware  x   USB Serial Controller       3  Install the device driver    1  Usually  when Windows recognizes the USB loader cable  the window shown  below appears   In some cases  depending on the Windows environment  it may  not appear   Select  No  not this time  and click the  Next  gt   button     Found New Hardware Wizard    Welcome to the Found New  Hardware Wizard    Windows will search for current and updated software by  looking on your computer  on the hardware installation CD  or on  the Windows Update Web site  with your permission      Read our privacy policy    Can Windows connect to Windows Update to searc
2.    y CSV Read Reads the trend data in CSV    format   CSV Out X  Outputs the trend data in CSV  Ctrl   x    i format   Clipboard Graph Outputs an image of the graph to  Ctrl   c   Out the Clipboard   Numeric Changes the display to the  Monitor numeric monitor    Help       Version A  Displays the version information     e Operating status display       The table below shows the relationship between the numerical value displayed at  the bottom of the screen and the operating status         Numeric display Status  Nam  0   Noalarm  a ae Alarm occurrence    OK lamp Lamp OFF  EV1  EV2    DI1 to DIS  Ext3 INPUT       Chapter 4  MONITORING THE CMQ V OPERATING STATUS    e Icon list      44 Returns the graph to the start time     4 Returns the graph by 1 2 screen     Ht   Returns the graph by 1 4 screen    b  Advances the graph by 1 4 screen   P Advances the graph by 1 2 screen        e Zooming the graph  Drag the mouse from the upper left portion to the lower right portion with the left  mouse button kept pressed     File Trend monitor Option Numeric Monitor Help    ESS AMA    l OD Am                         20  19  18  17   ihe po  lee 2S  LC poe  134     Ea E  IAE a  107     pre eee       8  7  64     piles  4  3    00 00 00       00 00 00  am sr fay aM Pv   aM valve   MaAlarm       MoK lamp    ame  MeEv2 l     oMon    onI    oMopis     MEtiNPUT                                                                                                 e Canceling the zoomed graph    Drag the 
3.  485 communications are connected   the CMC10L must be used  The CMC10L is an RS 232C  gt RS 485 converter    However  if the PC has a 3 wire RS 485 communications port  the CMC10L is  not required      USB loader cable  Accessory                          CMQ V with RS 485    communications j  function    Max  31 units    Note    e Personal computers used for confirmation of operating environment     Model No    Precision 380       Chapter 1  INTRODUCTION    1 3 MLP Installation    E MLP installation procedures  The MLP is installed on the hard disk of a personal computer  After installation           keep the system disk that you have purchased as a backup   This section describes how to install the MLP on a personal computer     o Handling Precautions  e Since the CD ROM does not include an operating system for a personal  computer  the program cannot be used on a personal computer which  does not have an OS     e  f you start up the Installer while another application is running  the  Installer may malfunction   Remove other resident applications from their directories before starting  up the Installer  The MLP sometimes cannot be started up depending on  the combination of other applications and drivers  For details on  Windows and personal computer settings  refer to the User s Manuals  provided with Windows and the personal computer     The following descriptions and sample screens are based on a personal computer  with Windows XP as the OS      1  Set the CD ROM in the
4.  6  Failure that arose from any reason not attributable to Yamatake  including  without limitation  acts of God   disasters  and actions taken by a third party   Please note that the term  warranty  as used herein refers to equipment only warranty  and Yamatake shall not  be liable for any damages  including direct  indirect  special  incidental or consequential damages in connection  with or arising out of Yamatake products     2  Ascertainment of suitability  You are required to ascertain the suitability of Yamatake product in case of your use of the same with your  machinery  equipment  etc   hereinafter referred to as  Equipment   on your own responsibility  taking the  following matters into consideration    1  Regulations and standards or laws that your Equipment is to comply with    2  Examples of application described in any documents provided by Yamatake are for your reference  purpose only  and you are required to check the functions and safety of your Equipment prior to your use    3  Measures to be taken to secure the required level of the reliability and safety of your Equipment in your use  Although Yamatake is constantly making efforts to improve the quality and reliability of Yamatake  products  there exists a possibility that parts and machinery may break down   You are required to provide your Equipment with fool proof design  fail safe design  anti flame  propagation design  safety design  or the like so that the said Equipment may satisfy the level of the 
5.  CD ROM drive of your personal computer    gt  gt The installation program starts automatically  and the USB MLP selection  screen appears       MLP install    O Before installing the driver  digconmect the USB connector     Install USB loader cable driver    Install WLF    Please select install program        2  Click  Install MLP  button    gt  gt The following screen appears     22 SOFTWARE LICENSE AGREEMENT    PLEASE READ THE FOLLOWING SOFTWARE  LICENSE AGREEMENT CAREFULLY BEFORE  CONTINUING     NOTE  YAMATAKE CORPORATION   HEREINAFTER REFERRED TO AS   YAMATAKE   IS WILLING TO LICENSE THIS  SOFTWARE TO YOU  HEREINAFTER  REFERRED TO AS THE  USER   ONLY ON THE  CONDITION THAT THE USER ACCEPTS ALL OF    THE TERMS CONTAINED IN THIS AGREEMENT   BY CLICKING ON THE  AGREE  BUTTON  THE  USER AGREES TO BE BOUND BY THE TERMS  OF THIS AGREEMENT  IF THE USER DOES  NOT AGREE TO THESE TERMS YAMATAKE IS  UNWILLING TO LICENSE THE SOFTWARE TO    v    Don t agree            Chapter 1  INTRODUCTION    E    3  If you agree to the software license agreement and wish to install the loader   click the  Agree  gt   button   If you abort the installation  click the  Don   t agree  button    gt  gt When clicking the  Agree  gt   button  the following screen appears        Get Registration Information    Please enter the name and company of the registered  owner of MLP100A100 into the fields below  All fields  must be filled in to proceed     Name     femme     Company      4  Enter a registered us
6.  Time  Language   and Regional Options       Regional and Language Options       Regional  Options       Customize          Decimal symbol   Select       and click  OK   button     33    Revision History    date    CP SPA2ieE  istedtion a SSCS    May 2009 RESTRICTIONS ON USE deleted    Operating system  Windows 98 Me deleted  and  Windows Vista added     Configuration with RS 485  explanation added   Section 1 3  title changed to MLP Installation   Procedure  1   explanation changed   Procedure  6   Note  explanation changed   Section title  changed to Installing the USB Loader  Cable Device Driver   Pagination changed  old pages 13 to 31    Handling Precautions  2nd item  explanation added   W Starting the MLP  screenshot changed   Menu screen changed   Setup screen changed   Step 1  screen changed   Step 2  Handling Precautions added   Step 4  explanation changed     Monitoring of run state and changing of  parameters changed to   Monitoring of operation  state and changing of parameters     Use of the command line  Handling Precautions   1st item  explanation changed    28 Display high limit of left axis  factory setting  changed from 1200 to 20    33 Note added    End of a book Terms and Conditions added           Terms and Conditions    We would like to express our appreciation for your purchase and use of Yamatake products    You are required to acknowledge and agree upon the following terms and conditions for your purchase of Yamatake  products  field instruments  cont
7.  V Series Digital Mass Flow Controller User s Manual  No  CP SP 1204E    or    CMQ V Series Digital Mass Flow Controller  for Hydrogen and Helium  Gases  User s Manual No  CP SP 1205E       Step 2  initialization      1  Click  4 icon   The operation is the same by selecting the  File       New  or the  Ctrl   n     keys      gt  gt The initialize dialog box appears     Information    j   Initialize Data       Cancel     2  Click  OK  button    gt  gt A new file opens     1  Handling Precautions  elf the CMQ V is a special model  not a standard model   do not initial     IZe     e For instructions on initializing a special model  contact Yamatake  Corporation       Step 3  setting up the environment     Set the communications port and font on the personal computer      1  Click    icon     The operation is the same by selecting the  Option      gt   Environment Setting   or  Ctrl   e  keys    gt  gt The Environment Setting dialog box appears     Port      comt  O con   O coms  O con4     cons  O CONG     com   Oconee       Communication setup    Environment Setting X        O cong    O conio  0  Loader cable    DAJ   a            O cow mStation sub add    O coni  Ol  RS 485  Ocon13             Ocon14 Communications conditions     coms J  8 data bits  even parii  Ocon16 1  8 data bits  no parii          Cae        x      Loader cable RS  48    Station address   Speed  1 0 38400b    2 J600bps          Fixed Cell Width          Font size   7J    OR       O 3                     
8.  fully open    Instantaneous SP No  in use  Instantaneous SP value in use  PV value  control flow rate   Valve drive output   Setting flow rate SPO   Setting flow rate SP1   Setting flow rate SP2   Setting flow rate SP3   Setting flow rate SP4   Setting flow rate SP5   Setting flow rate SP6   Setting flow rate SP7  Integrated event setting flowr ate  Integrated flow rate    Alarm   Event   External 3 way switching input  External switch   OK ramp   Slow start operation  Digital analog setting  Integrated count status   SP ramp control operation    e Even if the decimal point position for the PV display on the CMQ V has  been changed in function setup     38  the decimal point position in the  PV as displayed on the Numeric Monitor does not change     26    Chapter 4  MONITORING THE CMQ V OPERATING STATUS      Changing of data  The procedure described below is required to change data    1  Move the pointer to the data to be changed  and double click the left button of  the mouse  pressing the  Enter  key gives the same result     gt  gt The dialog box for data change is displayed    2  After changing the data  click the  OK  button      gt  gt The data is updated   e Changeable data    e Operation mode  e Instantaneous SP No  in use  e Setting flowrate SPO to SP7      J Handling Precautions   e Data change is not possible when the Numeric Monitor display is  stopped    e Depending on the function settings  a data change may not be made  even if the data change procedure is fol
9.  gt This starts writing of the setup parameters   During writing  the message  Please wait   is displayed   When writing ends  the message  Normal end  is displayed      J Handling Precautions  e  f writing fails  the message  Communications error has occurred  is  displayed  If writing is not possible  refer to   Chapter 5  TROUBLESHOOTING     21    Chapter 4  MONITORING THE CMQ V OPERATING STATUS    4 1       E Overview    Monitoring Function    To enter the monitor screens  click  Monitor  in the menu screen   There are two screens     Numeric monitor    and    Trend monitor    for monitoring   Each screen can be selected by the menu bar of the screen     e Numeric Monitor screen   This screen is for performing operations such as monitoring operating status   changing settings or switching modes   e Numeric display of the various operating parameters  parameters can be  changed   e Lamp indication of operating status of various items  e Alarm display  representative and detailed     e Trend Monitor screen   This screen is for monitoring operation status in graph format   e The screen displays graphs showing the trends in SP value  PV value and valve  drive output    If the personal computer is connected by RS 485 communications  trends for up  to 5 units can be displayed      e Screen display of digital data trends for max  of eight data items  e Export of sampled data as CSV file  e Trend screen dumps  e Sampling cycle  Variable within the range 1 to 3600s  Max  sampling 
10.  hardware specifications     MLP100 Loader Package for CMQ V Series Digital Mass Flow Controller  Manual No  CP SP 1216E    This manual   This manual is supplied with the MLP100 Loader Package     The manual describes the software used to make various settings for the  CMQ V Series using a personal computer  Personnel in charge of design or  setting of a system using the CMQ V Series must thoroughly read this man   ual  The manual describes installation of the software into a personal com   puter  operation of the personal computer  various functions  and setup pro   cedures     CMQ V Series Digital Mass Flow Controller  Communications  Manual No  CP SP 1197E    Those using the communications functions of the CMQ V Series should  read this manual     The manual gives an overview of communications  and describes transmis   sion protocols  CMQ V Series communications data  troubleshooting  and  communications specifications        Organization of This User s Manual       This manual is organized as follows     Chapter 1     Chapter 2     Chapter 3     Chapter 4     Chapter 5     INTRODUCTION   Be sure to read this chapter before using the MLP100  This chapter describes the required  operating environment for the personal computer  briefly introduces the features of the loader  program  and tells how to install it     STARTING AND QUITTING THE MLP  This chapter describes how to start and quit the MLP100     SETTING UP THE CMQ V    This chapter describes setup functions  screen l
11.  note that the descriptions contained in any documents provided by Yamatake are subject to change  without notice for improvement or for any other reason   For inquires or information on specifications as you may need to check  please contact our branch offices or sales  offices  or your local sales agents     8  Discontinuance of the supply of products parts  Please note that the production of any Yamatake product may be discontinued without notice   For repairable products  we will  in principle  undertake repairs for five  5  years after the discontinuance of those  products  In some cases  however  we cannot undertake such repairs for reasons  such as the absence of repair  parts   For field instruments  we may not be able to undertake parts replacement for similar reasons     azbil    Yam at ake Corporation Specifications are subject to change without notice   08   Advanced Automation Company    1 12 2 Kawana  Fujisawa  Kanagawa 251 8522 Japan  URL  http   www azbil com 1st Edition  Issued in Nov  2006  W   2nd Edition  Issued in May 2009  W     
12.  reliability and safety required in your use  whereby preventing any occurrence of physical injuries  fires   significant damage  and so forth     3  Precautions and restrictions on application  Yamatake products other than those explicitly specified as applicable  e g  Yamatake Limit Switch For Nuclear  Energy  shall not be used in a nuclear energy controlled area  radiation controlled area    Any Yamatake products shall not be used for with medical equipment   In addition   you are required to conduct a consultation with our sales representative and understand detail specifications   cautions for operation  and so forth by reference to catalogs  specifications  instruction manual   etc  in case that  you intend to use Yamatake product for any purposes specified in  1  through  6  below   Moreover  you are required to provide your Equipment with fool proof design  fail safe design  anti flame  propagation design and other designs of protection safety circuit on your own responsibility to ensure the  reliability and safety  whereby preventing problems caused by failure or nonconformity    1  For use under such conditions or in such environments as not stated in technical documents  including  catalogs  specification  and instruction manuals   2  For use of specific purposes  such as     Nuclear energy radiation related facilities   For use outside nuclear energy controlled areas   For use of Yamatake Limit Switch For Nuclear Energy     Machinery or equipment for space sea bot
13.  window    appears     Found New Hardware Wizard    Completing the Found New  Hardware Wizard  The wizard has finished installing the software for     F Yamatake USB Loader Comm port  i    Click Finish to close the wizard            4  Click  Finish     gt  gt When the installation is complete  the notification shown below appears on  the task tray  and Windows now correctly recognizes the USB loader cable     J  Found New Hardware  x   Your new hardware is installed and ready to use        11    Chapter 1  INTRODUCTION    E    5  Select  Control Panel   gt   System   gt   Hardware   gt   Device Manager   for  Windows XP 2000   and find the port number for the Yamatake USB Loader  Comm  from  Ports  COM  amp  LPT           Device Manager    File Action View Help      gt  Hee       2am  HIRS 9EFBASB1DA     Batteries  Computer      Disk drives  2 Display adapters  4B DYD CD ROM drives     Floppy disk controllers  JA Floppy disk drives  S IDE ATA ATAPI controllers   gt  Keyboards  1   Mice and other pointing devices  B   Network adapters       Pb Rp ae  Rl eh  Ep AR              U        3 Communications Port  COM1   F Communications Port  COM2   F Printer Port  LPT1   a Yamatake USB Loader Comm port  COM3      HR Processors      amp  SCSI and RAID controllers          Sound  video and game controllers    Sge Storage volumes              6  Start the MLP  select  Menu   gt   Option   and set to the communications port  number obtained in the previous step  Then press the  OK  bu
14. J       19    Chapter 3  SETTING UP THE CMQ V    20     2  Set the communications port  Select the port from the selection items    3  Set the font size  Select the front size from the selection items      4  Click  OK  button     o Handling Precautions  e When the  USB loader cable auto select  button is clicked  port selec   tion can be done automatically     e Normally  use  O Loader Cable        Step 4  Setting up CMQ V parameters     Set each of the parameters required for running the CMQ V   e Instantaneous flowrate   e Function setup   e Parameter setup   e Device information  Read only and cannot be changed     Note    e For details on the functions  refer to   CMQ V Series Digital Mass Flow Controller User s Manual  No  CP SP 1204E  or  CMQ V Series Digital Mass Flow Controller  for Hydrogen and Helium  Gases  User s Manual No  CP SP 1205E     Move the cursor to the target channel of each setup item  and perform the following  operations   e When the setting is a numerical value   Enter the numerical value  and press  Return  key     e When the setting is selected by a number  Press the right mouse button on a setting item   The list of settings you can select will appear   Select a desired item to complete the setting      1  Handling Precautions  e About connection to the personal computer   Normally  the CMQ V is connected to the personal computer with the  special cable   For the CMQ V unit with RS 485 communications  select  Option      gt    Type Setting  and s
15. No  CP SP 1216E       MLP100    Loader Package  for  CMQ V Series  Digital Mass Flow Controller    User s Manual       Thank you for purchasing the MLP100  Loader Package for CMQ V Series  Digital Mass Flow Controller     This manual contains information for  ensuring the correct use of the MLP100   It also provides necessary information  for installation  maintenance  and trou   bleshooting     This manual should be read by those  who design and maintain equipment  that uses the MLP100  Be sure to keep  this manual nearby for handy reference     Yamatake Corporation                            IMPORTANT    Do not apply a strong force while connecting a loader plug   Doing so might damage the instrument        L  Handling Precautions  Application of excessive force to the loader plug might cause    communication failure  If such failure happens  reconnect the loader  plug correctly              NOTICE  Be sure that the user receives this manual before the product is used     Copying or duplicating this users manual in part or in whole is forbid   den  The information and specifications in this manual are subject to  change without notice     Considerable effort has been made to ensure that this manual is free  from inaccuracies and omissions  If you should find an error or omis   sion  please contact Yamatake Corporation     In no event is Yamatake Corporation liable to anyone for any indirect   special or consequential damages as a result of using this product       2006 Yama
16. Setting dialog box is displayed     Model select       WOVOOD2ee NxOexxx       Gas type    OS  Oxygen OH  Hydrogen          Control flow range      9200  2 to 200  mL min   standard     1000  10 to 1000 L min standard       9500  0 004 to 0 500 L min standard      9005  0 10 to 5 00 mL mintstandard        0002  0 02 to 2 00 L min standard      9020  0 2 to 20 0 mL min standard      0005  0 04 to 5 00 L min standard       9050  0 4 to 50 0  mL min  standard      0010  0 10 to 10 00 L mintstandard       0020  0 1 to 20 0 L minstandard       0050  0 4 to 50 0 L min   standard       0200  2 to 200 L min   standard           0500  4 to 500 L min standard            Option     0 None     1 With RS 485 communication function                 2  Set the Control flow range and Option    3  Select from the selection items for each setting item      4  Click  OK  button     18    Chapter 3  SETTING UP THE CMQ V    n Handling Precautions  e  Type  set here is the setting for internal use on the loader  The model  number of the CMQ V will not change even if the type is changed on   the loader     elf the model number is unknown or not available for selection  first go  to the step 3  setting up the environment  and then return to model  number selection  After connecting the cable between the personal  computer and the CMQ V  click the  Model read  button  and the    model number will be automatically read out     Note    e For an explanation of each of the specifications  refer to     CMQ
17. TING UP THE CMQ V         Setup screen              Menu bar  File Edit  Tool bar     idea vy      Setup data  E Instantaneous flow  E Parameter setup  B Device Information  Selection  window    So     Setting Selection  ae al          Display Communication Setup Option Help    0  Key lock disabled o M      RUN key enabled  1  Operation is started up in the ope    Eal       Valid settings  0 to 2    Display Function setup  Key lock    RUN key operation and operation mode selection wh    ii G    Flow rate setup method  SP setup method selection  C 04 Number of flow set value  number of SPs selection  Input range selection of analog setup  analog SP    Analog output type and range selection     J    Event output 1 type assignment   Event output 2 type assignment   External 3 way switching function   assignment  2 w    External contact 1 input function    External contact 2 input function assignment  2 w    function assignment  2 w    when the    External contact 3 input  Automatic valve shut off totalized flow    C 14 On off of totalized flow reset function at start  Flow rate alarm setup type    Operation selection at alarm occurrence    Eoin Slow start setup  Gas type selection 1  Temperature at reference conditions    Valve amperage alarm setup    Address  RAM 2001  EEPROM 5001        Message window    16    _    Setup items           aj  a    Digital setup  set by key operation or communications        o            Number of SPs      1 SP 0 only        _      0 to 5   exter
18. aize   __  ___ Inilalzesthecellsize      Le src   with the window    CMQ V Series   gt  MLP  R    MLP   gt  CMQ V Series  W     Environment Setting a  Ctrl   e   flow rate A       F  C    Communication   Displays the CMQ V Series user s   functions manual for communications   Loader Displays the MLP100 user s manual   this manual      Displays the handling precautions   Displays the version informations     Information  Version A     1           Chapter 3  SETTING UP THE CMQ V    3   2 Setup Procedure       Configure setup in offline state  without connecting the cable to CMQ V      Click the  Option  on the menu screen  Set up in the following steps   The following tasks are performed   Step 1  Setting up the loader type  Step 2  Initialization  clearing previous setting values   Step 3  Setting up the environment  Step 4  Setting up CMQ V parameters  Step 5  Saving setup data  Step 6  Downloading the setup     J Handling Precautions  e Operations in steps 1 to 5 are required before the setup parameters  are entered on the CMQ V  Be sure to perform these steps   Otherwise  the MPC may be set up incorrectly  For example  the  required setup items may not be displayed or unrequired items may be  displayed     e Step 6 connects the cable to CMQ V       Step 1  setting up the loader type   Set up the loader type to match the CMQ V model number    1  Click   f icon   The operation is the same by selecting the  Option       Type Setting  or the   Ctrl   t  keys    gt  gt The Type 
19. als    provided with Windows     Click EJ icon at the top right of the screen   The operation is the same by selecting the  Menu       Quit     gt  gt The MLP is completed     Chapter 3  SETTING UP THE CMQ V    3   1 Setup Functions       E Overview  When the CMQ V is used for the first time  it will not function as required unless it  is set up by using this setup function   The setup function allows you to set the various parameters  about 10 to 70 con   stants required for operation  and write these parameters to the CMQ V so that it  functions according to your particular control requirements   Parameters such as SP  set point  and control constants that are changed relatively  frequently while the CMQ V is running can also be set from the monitor function  screen   By the setup function  parameters that hardly need changing later once they are set  are saved to file in list format before the CMQ V is run  and the saved file is called  up and written to the CMQ V in a single operation     mM Screen explanations      Menu screen       MLP1004100  Menu Help    Setup Monitor                MLPIOOA100  1 0  2    C  2006 2009 Yamatake Corporation All Rights Reserved  http   www  yamatake com           e Menu configuration list    a the Setup window   Ctrl   s     Monitor Displays the Monitor   Trend  Ctrl   m   window     Changes the environment setup   Ctrl   e   Quits the application   Ctrl   q   Version Displays the version information   Ctrl   a        15    Chapter 3  SET
20. ayout and the setup procedure     MONITORING THE CMQ V OPERATING STATUS    This chapter describes monitor functions  screen layout and methods of operation relating to  communications with a CMQ V Series device     TROUBLESHOOTING    This chapter describes remedies for problems that may occur while using this software     Contents    Unpacking       The Role of This Manual  Organization of This User s Manual  Conventions Used in This Manual    Chapter 1     1 1    1 2    Chapter 2     Chapter 3     3 1    3 2    Chapter 4     4 1    4 2    Chapter 5     5 1    INTRODUCTION  OVEIVICW  perar ire EE EA EE ETA EEA EE 1  E Loader functions i b5d 6 cee cls cei sees en oes ees ee we tek savedicanes 1  System Operating Environment              eeceececeecceceeceeceeeesenees 2  ACW ANG ooo ie oe oo ooo 6 ho 6S Ko SESS SOR Oe ewe NOE ee eR 2  M Hardware Configuration             eee eee cece cece cece cece cess eeeeeccees 2  MEP MSAA 6 36 6 e5dnd iia Eare NEEE IET ce eee thes kent beds ceseneeeeen 3  E MLP installation procedures             cccceeeee eee c cece eee eeeeecccees 3  Installing the USB Loader Cable Device Driver                    sssseeeeeee 7  E Installing the device Criver          cccec cece cece cece cece eee eeeeeeeeeeees 7  E Uninstalling the device river              cece cece cece cece cece eeeeeeeeees 13  STARTING AND QUITTING THE MLP  E Starting the MLP secesyccs ese wersavae wer eee arte seston wesc Ea 14  E Quitling tie MLP esse seca cee eee tre cass neadouen
21. computer and saving them as settings on the CMQ V       Monitoring function   Operating status or alarm occurrence of the CMQ V can be checked from a person   al computer  SP  flow rate setting  or operation mode can be changed during moni   toring  The operating status can be sampled and viewed as a graph  and the sampled  data can be output in CSV format so that it can be handled in third party spread   sheet software such as Microsoft Excel    The run state can also be checked on the Trend screen  and sampled data can be  output in CSV format so that it can be handled in third party spreadsheet software  such as Microsoft Excel      1  Handling Precautions  e The monitor target is limited to only one unit when the loader jack on  the side is used for performing monitoring     Chapter 1  INTRODUCTION    1 2 System Operating Environment       The following system environment is required for using the loader     E Hardware    Personal Computer   Target model PC AT compatibles with a Pentium chip or higher  32M byte or more    Operating system   Windows2000 Professional XP Home   XP Professional Vista  32 bits     USB Port 1 port or more  Use USB loader cable        E Hardware configuration      General configuration  connected with USB loader cable                Communications         c   AAA  lt     Q aeee   ea OOO RRA  cere FOE PD  EERE EFS OF  a    YG      Configuration with RS 485  CMQ V with RS 485 communications function only   If multiple CMQ V units  max  31  with RS
22. count  60 000  fixed regardless of number of data items to sample     Note    e A  CSV file  is the data format that can be handled in third party spreadsheet  software such as Microsoft Excel  In this format  sampled trend data can be  interpreted in spreadsheet software     These screens can be used to perform the following operations   e Monitoring of operating status and changing of various parameters on the  Numeric Monitor  e Switching of the operation mode on the Numeric Monitor  e Monitoring of trends and sampling of data while the CMQ V is operating  e Monitoring of alarms on the Numeric Monitor    L  Handling Precautions    22    e About connection to the personal computer  When making the setup or operating the monitor using the loader  con   nect the loader cable     e Before starting the trend monitor  configure the settings suitable for the  trend monitor     e The sampling cycle sometimes shifts due to fluctuations in the communi   cations cycle  To perform measurement at exact times  use the special  recorder or data logger     mM Screen explanations      Numeric monitor screen    Chapter 4  MONITORING THE CMQ V OPERATING STATUS    F  MLP100 Monitor Screen   Numeric Monitor  OFF   Trend Monitor  OFF  File Numeric Monitor M  Option O  Trend Monitor T  Help    Hox        Bass       Numeric Monitor       Alarm   Event   External 3 way switching  External switch   OK lamp   Slow start  Digital Analog  Integralation count value  SP ramp control       Numeric Monito
23. ear by repetitious open close operations   In addition  electronic components such as electrolytic capacitors will reach the end of their life due to aged  deterioration based on the conditions or environment in which such electronic components are used   Although acceleration of the above situation varies depending on the conditions or environment of use  the  number of open close operations of relays  etc   as prescribed in specifications or instruction manuals  or depending on the design margin of your machine or  equipment  you are required to renew any Yamatake products every 5 to 10 years unless otherwise specified in  specifications or instruction manuals   Field instruments  Sensors such as pressure flow level sensors  regulating valves  etc   will reach the end of their  life due to aged deterioration of parts   For those parts that will reach the end of their life due to aged deterioration  recommended replacement cycles are  prescribed  You are required to replace parts based on such recommended replacement cycles     6  Other precautions  Prior to your use of Yamatake products  you are required to understand and comply with specifications  e g    conditions and environment of use   precautions  warnings cautions notices as set forth in the technical documents  prepared for individual Yamatake products  such as catalogs  specifications  and instruction manuals to ensure the  quality  reliability  and safety of those products     7  Changes to specifications  Please
24. ected   The CMQ V is not connected   Connect the loader to the CMQ V   Power is not being supplied to  Supply power to the CMQ V     Cannot open communications  The communications port cannot Do not run the loader and other   port  software that uses the  communications port at the same  time     A communications error has  A system error occurred  Try again  or quit the loader to  occurred  Restart Windows  restart Windows   or  Check the connected There is a discrepancy in the Check the communications setup   instrument  communications setup  Check the cable connections and  contacts   The CMQ V is not connected   Supply power to the CMQ V     CMQ V Cannot support currently Wrong loader version for this Contact Yamatake Corporation  status error  connected CMQ V  CMQ V model  or its dealer     Flow range or gas type Mismatch of model numbers  Click  Read model  on the  mismatch between CMQ V and model selection screen to read  loader  Upload stopped  out the CMQ V model No     Parameter settings exceeded  Attempt to write data that After reading out the data from  range  Some data possibly not  exceeded the allowable range   the CMQ V  review the    For example  flow range or gas  parameter settings    type accidentally changed by   external contact of the CMQ V         31    Chapter 5  TROUBLESHOOTING    E File error messages    Category    File name  This filename is not valid  An invalid file name is input  Input a correct file name   error  This file cannot be found  A 
25. er name and company name  and then click the  Next  gt         button    gt  gt The following screen appears      2 Display Registration Information    This software has already been installed by the  following person  Ifyou are not licensed to use this  software you may not install this software onto your  computer         5  Click  Next  gt   button    gt  gt The following screen appears          Choose Destination Location    Setup will install MLP100A100 in the following folder     To install into a different folder  click Browse  and  select another folder     You can choose not to install MLP100A100 by clicking  Cancel to exit Setup        Note  e To change the installation destination directory  click  Browse     button     Chapter 1  INTRODUCTION     6  Click  Next  gt   button    gt  gt The following screen appears       Select Components    In the options list below  select the checkboxes for the  options that you would like to have installed  The disk space  fields reflect the requirements of the options you have  selected     M Sample program C  Builder   M Sample program F BASIC    POF filefjapanese    M PDF file english     Disk Space Required  151k  Disk Space Remaining  14736708 k     lt Back      Cancel         Note    e Check the necessary files  To display a PDF file  Adobe Reader is required  If    Adobe Reader is not already installed on your PC  download it from the  Adobe Systems webpage      7  Check on  put a check mark   W  software components you wi
26. ermareeaaneneceses 14  SETTING UP THE CMQ V  Setup FUNCHONS serrrrreirir troir tant eerste ese saceee arenes never esens a8 15  Me OOM CI VIEW oe E E E eh i heh esha ie tee wadesce nese octets bsaeesedaeeeee 15  M Screen explanations           sessessssssssssosssoosesossrossssocsesoes 15  Set  p PIOCEGUIE oxcse eves nvasss tin erna cpewinrrineh iene reyeeeeenunssetinks 18  MONITORING THE CMQ V OPERATIING STATUS  Monitoring FUNCTION        s e ssessssessssesssoesesessooesssossosesesoeseoe 22  E OvervieW a aso ois oe 5 ow ah he eed O44 e e a se 22  M Screen explanations            ccccccceee cece ccc ceseeeeeeeecesseeeeeees 23  Method of Operation          c cece cc ccc cece ccc cese sec csee nec ssesnecssesnes 26  E How to operate the numeric monitor screen               e eee eee wees 26  E How to operate the trend monitor            cece eee eee cece reece eeceees 28  TROUBLESHOOTING  Error Messages        essssssssssessscoesesocoseesoooseesososesssoceeesseoe 31  M Setup error messages           ssssessesssossoesesesoesosesoeseseseeees 31  E Communications error messages           es essssossesessossoseosees  31  E File error messages           esesesseooseesecosecssooceeesocoesesecoee  32  Other Troubleshooting          sessessssssosssessossosssesssesosssossoessos 33    iil    Conventions Used in This Manual       The following conventions are used in this manual     C  Handling Precautions      Note       1    2    3     OK  button       Option       Handling Precautions i
27. et  Loader cable RS 485  to  RS 485    The controller is then connected through the CMC10L   At this time  the environment setting and communication setup on the  CMQ V main unit must be adjusted beforehand   Additionally  configure the settings on the CMQ V in the offline mode   the cable is not connected to the CMQ V   For details  refer to   CMQ V Series Digital Mass Flow Controller  Communications  No  CP SP 1197E     Chapter 3  SETTING UP THE CMQ V      Step 5  saving setup data   When you have finished making the settings  save the setup   Saving setups in advance and using saved setups greatly reduces the time and load  when setting up the loader  The following items are saved   Type  e Setup parameters     1  The operation is the same by selecting the  File      gt   Save As  or  Ctrl   a   keys    gt  gt The Save As dialog box appears     Save As    Seve To   My eBooks    Bm Music     E  My Pictures       Fa pane  Save as lype    MLP1004100file   mit  v          2  Enter the file name  and click  Save  button       Step 6  downloading the setup   Write the set parameters or parameters called up from a saved file to the CMQ V    1  Use the special loader cable to connect the personal computer to the CMQ V  body      2  Turn the CMQ V ON      3  Click i icon   The operation is the same by selecting  Communication       Write   MLP   CMQ V Series   in the pull down menu    gt  gt The message  Writing is going to be executed  is displayed      4  Click  OK  button    gt 
28. etup                 Analog trend   mDigital trend    BJ  8707    B BC  Bo Soe OCR   Sle  Bl           set flowrate  Default     control flowrate       valve drive output             When each button is selected  the color selection screen will appear   Select a desired color     Chapter 4  MONITORING THE CMQ V OPERATING STATUS    Clicking  Default  will return the color setting to its initial value     Custom colors   BEE EEE g  BEE EEE Ee       e Trend trigger setup    File    Graph setup   Trend monitor color setup   Trend trigger setup    rOn trigger   Of trigger     Save trigger  O 0 None 0       0 None             O 7 Mode Control mode  O F Mode Control mode  O 7  ModefControl mode       8 Mode Fully open     8 Mode Fully open     8 Mode Fully open    Og Alarm O3 Alarm O3 Alarm      10 0K lamp    10 0K lamp    10 0K lamp      11 E  4  reverse     11 E  1  reverse     11 EV1  reverse       12 EV2 reverse     12 EV2 reverse     12 EV2 reverse       13 D11  reverse     13 D11  reverse  O 13 D11  reverse       14 Dl2 reverse     14 Dl2 reverse     14 Dl2 reverse       15 DI3 reverse     15 DI3 reverse     16 DI3 reverse       16 Mode Fully closed  reverse     16 Mode Fully closed  reverse      O 16 Mode Fully clased  reverse       17 Mode Control mode freverse     17 Mode Control mode  reverse   O 17 Mode Control mode  reverse      18 Mode Fully open  reverse     18 Mode Fully open  reverse     18 Mode Fully open  reverse   19 Alarm reverse     19 Alarm reverse     19 Alarm
29. file name not existing is input   Input an existing file name   Make sure that the correct path  and filename are given   This filename is a reserved A file name reserved for the Input a correct file name   device name  device name is input   Use a different filename   Disk error  Not enough free space on disk  The disk free capacity is Keep a sufficient disk free  insufficient  Capacity   The device is not ready The disk is not ready Prepare the disk and restart the  operation     Cannot make file  The CD ROM is specified as Save the file to another directory   save destination   File name too long  The file name is too long  Use 255 characters or less for  the file name     Pass name  The path does not exist An illegal path name is input Input a correct path name and  error Make sure that the correct path restart the operation    is given   File information   Illegal file size  The file is corrupted  Corrupted file cannot be used   error Illegal file information  Create a file again        32    Chapter 5  TROUBLESHOOTING    5   2 Other Troubleshooting          Numeric values are not If a decimal point symbol other than       Check that the decimal point  displayed correctly   period  is set  the loader does not function symbol is       period   If not  set  correctly  the cdecimal point symbol to         period    Note  e      period  should be set as the decimal separating symbol in the Windows con   trol panel     Example  for Windows XP  go to  Control Panel       Date 
30. freverse       20 0K larnptreverse     20 0K larnp reverse     20 0K lamptreverse     Stop delay Save folder   CAProgram Files rnlp MLP100  CJ    Trend triqgeris only in numeric monitor mode                               When setting up the trend triggers  the trend can be started and stopped accord   ing to the status of the numeric monitor   The trend trigger setup is valid only while the numeric monitor is running     When setting up the trend save triggers  the trend can be saved according to the  status of the numeric monitor    The file is saved into a specified trend save folder in the  TREND YYYY   MM DD HH MM SS CSV  format       Starting the data sampling  After completion of setup  click the tat icon   The same operation can be started by selecting  Trend Monitor      gt   Trend  Monitor Start     gt  gt The data sampling is started  and then the trend of the specified parameters is  displayed on the screen     e Once the trend monitor is started  it continues until the stop operation is per   formed or the data for 60 000 cycles is sampled     e If the stop operation is not performed  the data is overwritten onto the old data  when the data sampling for 60 000 cycles is completed     e The screen can be transited to the  Numeric Monitor  screen while the trend  monitor is running  However  the loader cannot be quitted or the screen can   not be transited to the  Setup  screen  To do so  quit the trend monitor     Note    e If the check mark    r   on the left of t
31. h for  software     O Yes  this time only     Yes  now and every time   connect a device    Click Next to continue           Chapter 1  INTRODUCTION        2  For the retrieval location of the device driver to be installed  select the  No  not  this time  and click the  Next  gt   button     Found New Hardware Wizard    This wizard helps you install software for   USB Serial Controller    9 E your hardware came with an installation CD    or floppy disk  insert it now   What do you want the wizard to do        Install from a list or specific location  Advanced     Click Next to continue         gt  gt Retrieval of the device driver starts     Found New Hardware Wizard        gt  gt When the device driver is found  the following window appears     Hardware Installation    The software you are installing for this hardware   Yamatake USB Loader Comm port    has not passed Windows Logo testing to verify its compatibility  with Windows XP   Tell me why this testing is important      Continuing your installation of this software may impair  correct    Seat dbeok as vende Saati eee a  passed Windows Logo testing        10    Chapter 1  INTRODUCTION        3  Click  Continue Anyway     gt  gt Installation of the device driver starts    Found New Hardware Wizard    Please wait while the wizard installs the software          F Yamatake USB Loader Comm port  fi    Yeslip sys  To C  WINDOWS system32 DRIVERS              gt  gt When the device driver installation is complete  the following
32. he item at the bottom of screen is  removed  the graph for that item is not displayed     29    Chapter 4  MONITORING THE CMQ V OPERATING STATUS      Stopping the data sampling  Select  Trend monitor       Trend monitor Stop    The trend monitor is then stopped       Saving sampled data  The data sampled using the trend monitor can be saved to a file in CSV format   The sampled data saved in CSV format can be processed using spreadsheet applica   tions  such as Microsoft Excel      1  Handling Precautions  e The data can be saved to a file even while the trend monitor is run   ning     e Saved data remains on the screen or on the personal computer until  some operation replaces it   The saved data can be read by selecting  Trend monitor      gt   CSV  Read   It also can be read using spreadsheet software       Saving clipboard graph output    Contents displayed on the Trend Monitor  such as SP value  PV value and valve  amperage  can be directly saved to the clipboard in the form of a screenshot     30    Chapter 5  TROUBLESHOOTING    5 1 Error Messages       E Setup error messages    Category    Cannot run multiple instances  Multiple instances of the MLP    Click  OK  button     of the MLP at the same time   program were started at the  same time        E Communications error messages    Category    Communi   Timed out  Message was not received Check the cable contacts  cations before the time out time  connections and contacts   error A device other than the CMQ V  is conn
33. ho  belongs to the administrator group  The USB loader cable is supported  on Windows 2000 XP Vista  32 bit type   It is not supported on 64 bit  Windows XP  or on Windows 95  Windows NT  MS DOS or PC DOS     e  fthere are multiple USB ports  connect the USB loader cable to the  same port every time  If it is connected to a different port  there is a  chance that driver installation may be required again     1  Put the SLP CD ROM into the CD ROM drive of the personal computer    gt  gt The installation program is then started up automatically and the following  screen appears        MLP install    O Before installing the driver  digconmect the USB connector     Install USB loader cable driver    Install MLP E    Please select install program        1  Click the  Install USB loader cable driver  button    gt  gt  The following screen appears     Yamatake USB Loader Cable Driver Installer    Welcome to the USB Loader Cable  Driver Installer     This wizard will walk you through updating the drivers for  your Yamatake USB device     To continue  click Next        Cancel       Chapter 1  INTRODUCTION     2  Click the  Next  gt   button    gt  gt  The following screen appears     Yamatake USB Loader Cable Driver Installer    End User License Agreement       lt Back J  __ Next gt  J  Cancel        3  Select  AGREE  and click the  Next gt   button    gt  gt The following screen appears      Yamatake USB Loader Cable Driver Installer    Installing the software for your Toaster device
34. lowed  For details  refer to   CMQ V Series Digital Mass Flow Controller User s Manual  No  CP SP 1204E  or  CMQ V Series Digital Mass Flow Controller  for Hydrogen and Helium  Gases  User s Manual No  CP SP 1205E       Use of the command line  Data can be read or written or the mode switched by directly entering communica   tions commands on the command line     1  Handling Precautions  e Use of the command line is not generally required  and sending an  erroneous command can cause problems  For instructions on setting  the command type  address  data  etc   contact Yamatake  Corporation     e For details on communications commands and data addresses   refer to   CMQ V Series Digital Mass Flow Controller  Communications  No  CP SP 1197E        Checking details of alarms  You can check the details of alarms in the Alarm window when an alarm occurs   e Click E   icon   The operation is the same by selecting the  Option  Q        Alarm  A     e The details of the alarm that is occurring are displayed       Handling Precautions   e This window displays the details of currently occurring alarms  and  does not have a function for restoring the CMQ V  To restore the  CMQ V  you must perform the appropriate remedy described in  CMQ V Series Digital Mass Flow Controller User s Manual  No  CP SP 1204E  or  CMQ V Series Digital Mass Flow Controller  for Hydrogen and Helium  Gases  User s Manual No  CP SP 1205E     27    Chapter 4  MONITORING THE CMQ V OPERATING STATUS    E How to opera
35. mouse from the lower right portion to the upper left portion with the left  mouse button kept pressed     Eile Trend monitor Option Numeric Monitor Help    ESHER   Madr  AADA          20  19       18   LRA er  164       oa       eile  104       00 00 00       00 00 00     aM Pv    M valve         MokKlamp     Mew  Mev2 g  oMpr    omn     MEx3INPUT                                                                                                       25    Chapter 4  MONITORING THE CMQ V OPERATING STATUS    4 2       Method of Operation    E How to operate the numeric monitor screen      Start of monitoring  start of communications   The operation described below is required to start monitoring     Otherwise  monitoring and rewriting of data cannot be performed     e Click FE  icon     The operation is the same by selecting  Numeric Monitor       Numeric Monitor    Start       gt  gt During normal operation  The data on the CMQ V is displayed     During an error     The message  Check the device to which the  loader is connected  is displayed  Remedy  according to Chapter 5  TROUBLESHOOTING     The following operations are possible when the device and the loader are correctly    connected       Monitoring of operation state and changing of parameters    Operation mode    Numeric monitor   displayed in table format   Numeric group monitor    State monitor     displayed in lamp lighting    format     L  Handling Precautions       0  Valve fully closed  1   Valve control  2   Valve
36. nal reference input            0 to 5   instantaneous flow rate output      Not used  OFF at all times             Not used  OFF at all times          Not    used         Not    Not    Not    used  used    used       Function disabled       Function disabled       _    oo    o oo    o   oe o                    Upper   lower limit alarm used      Control continued and alarm output ON            Slow start disabled         Air  nitrogen             20  C  1 atmosphere         Valve amperage alarm disabled    Chapter 3  SETTING UP THE CMQ V      Menu configuration list    Menu    File    Edit  Display    Communicatio    Setup    Option    D  D         SaveAs fe Saves the active data with name   Ctrl   a   po CSV Out X  Pe Saves the active data in CSV format   Ctrl   x         ATC out  __  Savesthe active detain HTML format    Cirith   rr Prints the active data  with same a  contents as HTML output    a     Five most recent files        Function setup B    Displays or sets the function setup  Ctrl    Shift   b     Parameter setup   Displays or sets the parameter setup   Ctrl   Shift   c   Device Information  Displays the device related data   Ctrl   Shift   d     PDF Installation and   Displays the CMQ V Series user s  F1   Configuration manual       fon f o Quits the apicatn  S oa       Data Check     Checks aliseting values    Orima  Parameter disparea  ___  Displays tne parameter display area   intenable       pispaysmenm  Auiosize     Makes the auto cellsize enabled   Sizeint
37. ndicate items that the user should pay attention to  when handling the MLP100     Notes indicate useful information that the user might benefit by knowing     The numbers with the parenthesis indicate steps in a sequence or indicate  corresponding parts in an explanation     Indicates a selection button in screens displayed on the personal  computer     Indicates messages and menus displayed on the personal computer      Option       Type Setting        gt  gt        Ctrl  key     a  key     Ctrl   a  key      Indicates the order to select the  Option  first and then select the   Type Setting  displayed on the personal computer     Indicates the result of an operation  details displayed on the personal  computer or devices  or the state of a device after an operation     Indicates keys on the keyboard     Indicates the operation of pressing the  a  key with the  Ctrl  key on the  keyboard held down     Chapter 1  INTRODUCTION    1 1 Overview       The MLP100  or simply  the MLP   is a software program for setting various parameters and monitoring the oper   ating state of a CMQ V Series Digital Mass Flow Controller  simply  CMQ V  from here on  on a personal com   puter    The MLP runs on Windows2000 XP Vista  simply called  Windows  from here on  on a personal computer     E Loader functions  The MLP has the following functions   e Setup  e Monitor      Setup function  This function is for inputting various parameters required for the operation of the  CMQ V into a personal 
38. nge Remove  button     Uninstall Driver Package      2   All devices using this driver will be removed  Do you wish to continue         2  Click the  Yes  button      3  Restart the computer     13    Chapter 2        STARTING AND QUITTING  THE MLP     o Handling Precautions    E Starting the MLP    E Quitting the MLP    14    e Before starting up the MLP  quit all other applications   If you start up loader while another application is running  the MLP may  not function   Also  set the power save setting  infrared communications and screen  saver to OFF     e Make sure that the  Decimal symbol  has been set to       for  Control  Panel       Regional Settings       Number   If it has been set to some  other character  the loader program cannot function correctly    Example  for Windows XP  go to  Control Panel       Date  Time   Language  and Regional Options       Regional and Language Options        Regional Options       Customize          Decimal symbol   Select        and click  OK  button       Double click the MLP100A100 icon on the desk top or click  Start  button at  the lower portion of the screen and select  Programs      gt   MLP   gt    MLP100A100      gt  gt The MLP is started up and the menu window is displayed     2 MLP100A100 ba  ol    Setup Monitor                 MLPIOOA100  1 0  2    C  2006 2009 Yamatake Corporation All Rights Reserved  http   www  yamatake  com        Note    e For the operating system details and the mouse setup  refer to User   s Manu
39. r  Operation mode  Instantaneous SP No  in use       Instantaneous SP value in use  Instantaneous P   value   Valve actuation current     Digital instantaneous flowrate SP O         Digital instantaneous flowrate SP 1         Digital instantaneous flowrate SP 2         Digital instantaneous flowrate SP 3         Digital instantaneous flowrate SP 64         Digital instantaneous flowrate SP 6         Digital instantaneous flowrate SP 7         Digital instantaneous flowrate SP 8         Integrated SP flowrate   Integrated PY flowrate                      e Menu configuration list       Numeric Numeric Monitor Starts stops the monitor   Ctrl   m   Monitor  M    EEI   Start Stop  M   Option  O  Reset integrated Resets the integrated flowrate    flow rate  R     Alarm  A  Displays the Alarm Details window a  KI Command Line  C    Displays the Command Line  Ei window     Changes the display to the trend    Trend  Monitor  T  monitor     Displays the version information        23    24    Chapter 4  MONITORING THE CMQ V OPERATING STATUS      Trend monitor screen    ej Trend monitor    File Trend monitor Option Numeric Monitor Help             Es   a4    gt   gt    QD AUM       20  19  18  17  16  15  14  13  12  11   10    00 00 00       00 00 00    M  SP1        MP        M Valvet    v  Alarm   V  OK lamp B V  Ev1 B V  Ev2  omon oM  DI opis    V  Ext3INPUT       e Menu configuration list    Trend Pr Trend monitor Starts stops the trend monitor   Ctrl   t   monitor Start Stop  T   
40. rol valves  and control products   unless otherwise stated in any separate document   including  without limitation  estimation sheets  written agreements  catalogs  specifications and instruction manuals     1  Warranty period and warranty scope  1 1 Warranty period  Yamatake products shall be warranted for one  1  year from the date of your purchase of the said products or the  delivery of the said products to a place designated by you   1 2 Warranty scope  In the event that Yamatake product has any failure attributable to Yamatake during the aforementioned warranty  period  Yamatake shall  without charge  deliver a replacement for the said product to the place where you  purchased  or repair the said product and deliver it to the aforementioned place   Notwithstanding the foregoing  any failure falling under one of the following shall not be covered under this  warranty    1  Failure caused by your improper use of Yamatake product   noncompliance with conditions  environment of use  precautions  etc  set forth in catalogs  specifications   instruction manuals  etc      2  Failure caused for other reasons than Yamatake product    3  Failure caused by any modification or repair made by any person other than Yamatake or Yamatake s  subcontractors    4  Failure caused by your use of Yamatake product in a manner not conforming to the intended usage of that  product    5  Failure that the state of the art at the time of Yamatake s shipment did not allow Yamatake to predict  or  
41. sh to install and  click  Next  gt   button      gt  gt The following screen appears    2 Select Start Menu Group    Enter the name ofthe Start Menu group to add  MLP100A100 icons to     Accessories  Administrative Tools    Cancel         Note    e To change the program folder  enter the new folder name      8  Click  Next  gt   button    gt  gt The following screen appears          Start Installation    You are now ready to install MLP100A100     Press the Next button to begin the installation or the  Back button to reenter the installation information     Cancel         Chapter 1  INTRODUCTION     9  Click  Next  gt   button    gt  gt The following screen appears     s5 Installation Complete        10 Click  Finish  gt   button      gt  gt When the installation is completed successfully  the screen will return to the  Windows screen     Chapter 1  INTRODUCTION    1 4 Installing the USB Loader Cable Device Driver       A device driver must be installed before using the USB loader cable   Follow the procedure below to install the device driver     E Installing the device driver    L  Handling Precautions  e Be sure to follow the procedure below when installing the device driver   The USB cable may not be recognized if the procedure is not followed  If  the cable is not recognized  uninstall the driver and then install it again     e Administrator privileges on the computer are required for driver installa   tion  Installation should be done by the administrator or by a user w
42. take Corporation ALL RIGHTS RESERVED    Micro Flow     uF  and CMQ       are trademarks of Yamatake Corporation              The Role of This Manual       In all  four manuals have been prepared for the CMQ V Series  Read the manual according to your specific require   ments    The following lists all the manuals that accompany the CMQ V Series and gives a brief outline of the manual    If you do not have the required manual  contact Yamatake Corporation or your dealer     CMQ V Series Digital Mass Flow Controller  Manual No  CP SP 1204E    First time users of the CMQ V Series  and those in charge of maintenance  or hardware design for incorporating a CMQ V Series controller in instru   mentation should read this manual     This manual outlines the product  tells how to install  wire  and incorporate  the product into instrumentation  and describes its operation  inspection and  maintenance  troubleshooting  and hardware specifications     CMQ V Series Digital Mass Flow Controller  for Hydrogen and Helium Gases     Manual No  CP SP 1205E    First time users of the CMQ V Series  for hydrogen and helium gases   and  those in charge of maintenance or hardware design for incorporating a  CMQ V Series controller  For hydrogen and helium gases  in instrumenta   tion should read this manual     This manual outlines the product  tells how to install  wire  and incorporate  the product into instrumentation  and describes its operation  inspection and  maintenance  troubleshooting  and
43. te the trend monitor      Setup    28    Select  Graph setup    Station address setup    Trend monitor color setup    and  Trend trigger setup  at  Option  Q        Setup   and make the settings  below for each sampled data    As the cycle and display upper lower limits are common to all channels     e Graph setup  left axis is flow rate  right axis is valve amperage     Setting item Setting range Factory setting  Cycle  Setting of sampling cycle  1 to 3600s    Display low limit  Lower value of left vertical   1999 to display upper  of left axis axis of screen display limit    Display high limit Upper value of left vertical  Display lower limit to 20  of left axis axis of screen display 9999   Display low limit  Lower value of right vertical   1999 to display upper  10  of right axis axis of screen display limit   Display high limit  Upper value of right vertical  Display lower limit to 110  of right axis axis of screen display 9999     1  Handling Precautions  e Be sure to change the sampling cycle setting only when trend monitor   ing is stopped        e Station address setup  only for RS 485 communications     Setting item Setting range   setting    Station address to  Sets the station  0  Not used   which the data is address 1 to 127  Station address   transmitted   Station subaddress   orea   o  o Handling Precautions    e Can be set only if  1  RS 485  is selected for  Loader cable RS 485  at  step 3  Setting up the environment  on page 18        e Trend monitor color s
44. tom    Transportation equipment   Railway  aircraft  vessels  vehicle equipment  etc      Antidisaster crime prevention equipment    Burning appliances    Electrothermal equipment    Amusement facilities   3  Supply systems such as electricity gas water supply systems  large scale communication systems  and  traffic air traffic control systems requiring high reliability   4  Facilities that are to comply with regulations of governmental public agencies or specific industries   5  Machinery or equipment that may affect human lives  human bodies or properties   6  Other machinery or equipment equivalent to those set forth in items  1  to  5  above which require high  reliability and safety    4  Precautions against long term use  Use of Yamatake products  including switches  which contain electronic components  over a prolonged period may  degrade insulation or increase contact resistance and may result in heat generation or any other similar problem  causing such product or switch to develop safety hazards such as smoking  ignition  and electrification   Although acceleration of the above situation varies depending on the conditions or environment of use of the  products  you are required not to use any Yamatake products for a period exceeding ten  10  years unless  otherwise stated in specifications or instruction manuals     5  Recommendation for renewal  Mechanical components  such as relays and switches  used for Yamatake products will reach the end of their life  due to w
45. tton to complete  the configuration     Evronnent Selime Eg    Communication setup TT Font size  Port Loader cable RS 48  j address Speed O7              coN Ocona   1 al 0 38400bps  Ocon  Oconto      1 19200bps O 8  Ocows    Ocowi _ sub add     2 9800bps        0  Loader cable          Ocom Ocome O1  RS 485 o S  piai  i  O cons O com      cone   con14 Communications conditions  O con     cont   0  8 data bits  even parity 1 stop bit  O cone    com16 1  8 data bits  no parity 2 stop bits       4 2400bps Gi          O11                         Fixed Cell Width                        Note    e When the  USB loader cable auto select  button is clicked  port selection  can be done automatically      Note    e Ifthe CD ROM for the MLP is not available  execute drvsetup exe on the  computer on which the MLP is installed  Then install the device driver   Normally  C  Program Files mlp MLP 100      12    Chapter 1  INTRODUCTION    E Uninstalling the device driver     J Handling Precautions  e Removing the driver requires restarting the computer  Close other  applications first  and then uninstall the driver     e To uninstall the driver  administrator rights are required on the computer   Uninstalling should be done by the administrator or by a user who  belongs to the administrator group     1  Execute the driver removal program    1  Go to  Control Panel   gt   Add or Remove Programs  and click on   Windows Driver Package   Yamatake  YC slp  USB  04 19 2007  1 0 0    Click the  Cha
    