Home
MLP100 User`s Manual
Contents
1. Software Installation Continue Anyway STOP Installation Chapter 1 INTRODUCTION 4 Click the Continue Anyway button gt gt The installation program then starts up and after it is completed the follow ing screen appears Yamatake USB Loader Cable Driver Installer Congratulations The drivers were successfully installed on this computer You can now connect your device to this computer IF your device came with instructions please read them first Driver Name Status y Yamatake YCsIp USB Ready to use 5 Click Finish button to complete the installation 2 Insert the USB loader cable into the USB port gt gt When Windows recognizes the USB cable the notification shown below appears on the task tray and the driver installation wizard appears LON i Found New Hardware x USB Serial Controller 3 Install the device driver 1 Usually when Windows recognizes the USB loader cable the window shown below appears In some cases depending on the Windows environment it may not appear Select No not this time and click the Next gt button Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Read our privacy policy Can Windows connect to Windows Update to searc
2. y CSV Read Reads the trend data in CSV format CSV Out X Outputs the trend data in CSV Ctrl x i format Clipboard Graph Outputs an image of the graph to Ctrl c Out the Clipboard Numeric Changes the display to the Monitor numeric monitor Help Version A Displays the version information e Operating status display The table below shows the relationship between the numerical value displayed at the bottom of the screen and the operating status Numeric display Status Nam 0 Noalarm a ae Alarm occurrence OK lamp Lamp OFF EV1 EV2 DI1 to DIS Ext3 INPUT Chapter 4 MONITORING THE CMQ V OPERATING STATUS e Icon list 44 Returns the graph to the start time 4 Returns the graph by 1 2 screen Ht Returns the graph by 1 4 screen b Advances the graph by 1 4 screen P Advances the graph by 1 2 screen e Zooming the graph Drag the mouse from the upper left portion to the lower right portion with the left mouse button kept pressed File Trend monitor Option Numeric Monitor Help ESS AMA l OD Am 20 19 18 17 ihe po lee 2S LC poe 134 Ea E IAE a 107 pre eee 8 7 64 piles 4 3 00 00 00 00 00 00 am sr fay aM Pv aM valve MaAlarm MoK lamp ame MeEv2 l oMon onI oMopis MEtiNPUT e Canceling the zoomed graph Drag the
3. 485 communications are connected the CMC10L must be used The CMC10L is an RS 232C gt RS 485 converter However if the PC has a 3 wire RS 485 communications port the CMC10L is not required USB loader cable Accessory CMQ V with RS 485 communications j function Max 31 units Note e Personal computers used for confirmation of operating environment Model No Precision 380 Chapter 1 INTRODUCTION 1 3 MLP Installation E MLP installation procedures The MLP is installed on the hard disk of a personal computer After installation keep the system disk that you have purchased as a backup This section describes how to install the MLP on a personal computer o Handling Precautions e Since the CD ROM does not include an operating system for a personal computer the program cannot be used on a personal computer which does not have an OS e f you start up the Installer while another application is running the Installer may malfunction Remove other resident applications from their directories before starting up the Installer The MLP sometimes cannot be started up depending on the combination of other applications and drivers For details on Windows and personal computer settings refer to the User s Manuals provided with Windows and the personal computer The following descriptions and sample screens are based on a personal computer with Windows XP as the OS 1 Set the CD ROM in the
4. 6 Failure that arose from any reason not attributable to Yamatake including without limitation acts of God disasters and actions taken by a third party Please note that the term warranty as used herein refers to equipment only warranty and Yamatake shall not be liable for any damages including direct indirect special incidental or consequential damages in connection with or arising out of Yamatake products 2 Ascertainment of suitability You are required to ascertain the suitability of Yamatake product in case of your use of the same with your machinery equipment etc hereinafter referred to as Equipment on your own responsibility taking the following matters into consideration 1 Regulations and standards or laws that your Equipment is to comply with 2 Examples of application described in any documents provided by Yamatake are for your reference purpose only and you are required to check the functions and safety of your Equipment prior to your use 3 Measures to be taken to secure the required level of the reliability and safety of your Equipment in your use Although Yamatake is constantly making efforts to improve the quality and reliability of Yamatake products there exists a possibility that parts and machinery may break down You are required to provide your Equipment with fool proof design fail safe design anti flame propagation design safety design or the like so that the said Equipment may satisfy the level of the
5. CD ROM drive of your personal computer gt gt The installation program starts automatically and the USB MLP selection screen appears MLP install O Before installing the driver digconmect the USB connector Install USB loader cable driver Install WLF Please select install program 2 Click Install MLP button gt gt The following screen appears 22 SOFTWARE LICENSE AGREEMENT PLEASE READ THE FOLLOWING SOFTWARE LICENSE AGREEMENT CAREFULLY BEFORE CONTINUING NOTE YAMATAKE CORPORATION HEREINAFTER REFERRED TO AS YAMATAKE IS WILLING TO LICENSE THIS SOFTWARE TO YOU HEREINAFTER REFERRED TO AS THE USER ONLY ON THE CONDITION THAT THE USER ACCEPTS ALL OF THE TERMS CONTAINED IN THIS AGREEMENT BY CLICKING ON THE AGREE BUTTON THE USER AGREES TO BE BOUND BY THE TERMS OF THIS AGREEMENT IF THE USER DOES NOT AGREE TO THESE TERMS YAMATAKE IS UNWILLING TO LICENSE THE SOFTWARE TO v Don t agree Chapter 1 INTRODUCTION E 3 If you agree to the software license agreement and wish to install the loader click the Agree gt button If you abort the installation click the Don t agree button gt gt When clicking the Agree gt button the following screen appears Get Registration Information Please enter the name and company of the registered owner of MLP100A100 into the fields below All fields must be filled in to proceed Name femme Company 4 Enter a registered us
6. Time Language and Regional Options Regional and Language Options Regional Options Customize Decimal symbol Select and click OK button 33 Revision History date CP SPA2ieE istedtion a SSCS May 2009 RESTRICTIONS ON USE deleted Operating system Windows 98 Me deleted and Windows Vista added Configuration with RS 485 explanation added Section 1 3 title changed to MLP Installation Procedure 1 explanation changed Procedure 6 Note explanation changed Section title changed to Installing the USB Loader Cable Device Driver Pagination changed old pages 13 to 31 Handling Precautions 2nd item explanation added W Starting the MLP screenshot changed Menu screen changed Setup screen changed Step 1 screen changed Step 2 Handling Precautions added Step 4 explanation changed Monitoring of run state and changing of parameters changed to Monitoring of operation state and changing of parameters Use of the command line Handling Precautions 1st item explanation changed 28 Display high limit of left axis factory setting changed from 1200 to 20 33 Note added End of a book Terms and Conditions added Terms and Conditions We would like to express our appreciation for your purchase and use of Yamatake products You are required to acknowledge and agree upon the following terms and conditions for your purchase of Yamatake products field instruments cont
7. V Series Digital Mass Flow Controller User s Manual No CP SP 1204E or CMQ V Series Digital Mass Flow Controller for Hydrogen and Helium Gases User s Manual No CP SP 1205E Step 2 initialization 1 Click 4 icon The operation is the same by selecting the File New or the Ctrl n keys gt gt The initialize dialog box appears Information j Initialize Data Cancel 2 Click OK button gt gt A new file opens 1 Handling Precautions elf the CMQ V is a special model not a standard model do not initial IZe e For instructions on initializing a special model contact Yamatake Corporation Step 3 setting up the environment Set the communications port and font on the personal computer 1 Click icon The operation is the same by selecting the Option gt Environment Setting or Ctrl e keys gt gt The Environment Setting dialog box appears Port comt O con O coms O con4 cons O CONG com Oconee Communication setup Environment Setting X O cong O conio 0 Loader cable DAJ a O cow mStation sub add O coni Ol RS 485 Ocon13 Ocon14 Communications conditions coms J 8 data bits even parii Ocon16 1 8 data bits no parii Cae x Loader cable RS 48 Station address Speed 1 0 38400b 2 J600bps Fixed Cell Width Font size 7J OR O 3
8. fully open Instantaneous SP No in use Instantaneous SP value in use PV value control flow rate Valve drive output Setting flow rate SPO Setting flow rate SP1 Setting flow rate SP2 Setting flow rate SP3 Setting flow rate SP4 Setting flow rate SP5 Setting flow rate SP6 Setting flow rate SP7 Integrated event setting flowr ate Integrated flow rate Alarm Event External 3 way switching input External switch OK ramp Slow start operation Digital analog setting Integrated count status SP ramp control operation e Even if the decimal point position for the PV display on the CMQ V has been changed in function setup 38 the decimal point position in the PV as displayed on the Numeric Monitor does not change 26 Chapter 4 MONITORING THE CMQ V OPERATING STATUS Changing of data The procedure described below is required to change data 1 Move the pointer to the data to be changed and double click the left button of the mouse pressing the Enter key gives the same result gt gt The dialog box for data change is displayed 2 After changing the data click the OK button gt gt The data is updated e Changeable data e Operation mode e Instantaneous SP No in use e Setting flowrate SPO to SP7 J Handling Precautions e Data change is not possible when the Numeric Monitor display is stopped e Depending on the function settings a data change may not be made even if the data change procedure is fol
9. gt This starts writing of the setup parameters During writing the message Please wait is displayed When writing ends the message Normal end is displayed J Handling Precautions e f writing fails the message Communications error has occurred is displayed If writing is not possible refer to Chapter 5 TROUBLESHOOTING 21 Chapter 4 MONITORING THE CMQ V OPERATING STATUS 4 1 E Overview Monitoring Function To enter the monitor screens click Monitor in the menu screen There are two screens Numeric monitor and Trend monitor for monitoring Each screen can be selected by the menu bar of the screen e Numeric Monitor screen This screen is for performing operations such as monitoring operating status changing settings or switching modes e Numeric display of the various operating parameters parameters can be changed e Lamp indication of operating status of various items e Alarm display representative and detailed e Trend Monitor screen This screen is for monitoring operation status in graph format e The screen displays graphs showing the trends in SP value PV value and valve drive output If the personal computer is connected by RS 485 communications trends for up to 5 units can be displayed e Screen display of digital data trends for max of eight data items e Export of sampled data as CSV file e Trend screen dumps e Sampling cycle Variable within the range 1 to 3600s Max sampling
10. hardware specifications MLP100 Loader Package for CMQ V Series Digital Mass Flow Controller Manual No CP SP 1216E This manual This manual is supplied with the MLP100 Loader Package The manual describes the software used to make various settings for the CMQ V Series using a personal computer Personnel in charge of design or setting of a system using the CMQ V Series must thoroughly read this man ual The manual describes installation of the software into a personal com puter operation of the personal computer various functions and setup pro cedures CMQ V Series Digital Mass Flow Controller Communications Manual No CP SP 1197E Those using the communications functions of the CMQ V Series should read this manual The manual gives an overview of communications and describes transmis sion protocols CMQ V Series communications data troubleshooting and communications specifications Organization of This User s Manual This manual is organized as follows Chapter 1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 INTRODUCTION Be sure to read this chapter before using the MLP100 This chapter describes the required operating environment for the personal computer briefly introduces the features of the loader program and tells how to install it STARTING AND QUITTING THE MLP This chapter describes how to start and quit the MLP100 SETTING UP THE CMQ V This chapter describes setup functions screen l
11. note that the descriptions contained in any documents provided by Yamatake are subject to change without notice for improvement or for any other reason For inquires or information on specifications as you may need to check please contact our branch offices or sales offices or your local sales agents 8 Discontinuance of the supply of products parts Please note that the production of any Yamatake product may be discontinued without notice For repairable products we will in principle undertake repairs for five 5 years after the discontinuance of those products In some cases however we cannot undertake such repairs for reasons such as the absence of repair parts For field instruments we may not be able to undertake parts replacement for similar reasons azbil Yam at ake Corporation Specifications are subject to change without notice 08 Advanced Automation Company 1 12 2 Kawana Fujisawa Kanagawa 251 8522 Japan URL http www azbil com 1st Edition Issued in Nov 2006 W 2nd Edition Issued in May 2009 W
12. reliability and safety required in your use whereby preventing any occurrence of physical injuries fires significant damage and so forth 3 Precautions and restrictions on application Yamatake products other than those explicitly specified as applicable e g Yamatake Limit Switch For Nuclear Energy shall not be used in a nuclear energy controlled area radiation controlled area Any Yamatake products shall not be used for with medical equipment In addition you are required to conduct a consultation with our sales representative and understand detail specifications cautions for operation and so forth by reference to catalogs specifications instruction manual etc in case that you intend to use Yamatake product for any purposes specified in 1 through 6 below Moreover you are required to provide your Equipment with fool proof design fail safe design anti flame propagation design and other designs of protection safety circuit on your own responsibility to ensure the reliability and safety whereby preventing problems caused by failure or nonconformity 1 For use under such conditions or in such environments as not stated in technical documents including catalogs specification and instruction manuals 2 For use of specific purposes such as Nuclear energy radiation related facilities For use outside nuclear energy controlled areas For use of Yamatake Limit Switch For Nuclear Energy Machinery or equipment for space sea bot
13. window appears Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for F Yamatake USB Loader Comm port i Click Finish to close the wizard 4 Click Finish gt gt When the installation is complete the notification shown below appears on the task tray and Windows now correctly recognizes the USB loader cable J Found New Hardware x Your new hardware is installed and ready to use 11 Chapter 1 INTRODUCTION E 5 Select Control Panel gt System gt Hardware gt Device Manager for Windows XP 2000 and find the port number for the Yamatake USB Loader Comm from Ports COM amp LPT Device Manager File Action View Help gt Hee 2am HIRS 9EFBASB1DA Batteries Computer Disk drives 2 Display adapters 4B DYD CD ROM drives Floppy disk controllers JA Floppy disk drives S IDE ATA ATAPI controllers gt Keyboards 1 Mice and other pointing devices B Network adapters Pb Rp ae Rl eh Ep AR U 3 Communications Port COM1 F Communications Port COM2 F Printer Port LPT1 a Yamatake USB Loader Comm port COM3 HR Processors amp SCSI and RAID controllers Sound video and game controllers Sge Storage volumes 6 Start the MLP select Menu gt Option and set to the communications port number obtained in the previous step Then press the OK bu
14. J 19 Chapter 3 SETTING UP THE CMQ V 20 2 Set the communications port Select the port from the selection items 3 Set the font size Select the front size from the selection items 4 Click OK button o Handling Precautions e When the USB loader cable auto select button is clicked port selec tion can be done automatically e Normally use O Loader Cable Step 4 Setting up CMQ V parameters Set each of the parameters required for running the CMQ V e Instantaneous flowrate e Function setup e Parameter setup e Device information Read only and cannot be changed Note e For details on the functions refer to CMQ V Series Digital Mass Flow Controller User s Manual No CP SP 1204E or CMQ V Series Digital Mass Flow Controller for Hydrogen and Helium Gases User s Manual No CP SP 1205E Move the cursor to the target channel of each setup item and perform the following operations e When the setting is a numerical value Enter the numerical value and press Return key e When the setting is selected by a number Press the right mouse button on a setting item The list of settings you can select will appear Select a desired item to complete the setting 1 Handling Precautions e About connection to the personal computer Normally the CMQ V is connected to the personal computer with the special cable For the CMQ V unit with RS 485 communications select Option gt Type Setting and s
15. No CP SP 1216E MLP100 Loader Package for CMQ V Series Digital Mass Flow Controller User s Manual Thank you for purchasing the MLP100 Loader Package for CMQ V Series Digital Mass Flow Controller This manual contains information for ensuring the correct use of the MLP100 It also provides necessary information for installation maintenance and trou bleshooting This manual should be read by those who design and maintain equipment that uses the MLP100 Be sure to keep this manual nearby for handy reference Yamatake Corporation IMPORTANT Do not apply a strong force while connecting a loader plug Doing so might damage the instrument L Handling Precautions Application of excessive force to the loader plug might cause communication failure If such failure happens reconnect the loader plug correctly NOTICE Be sure that the user receives this manual before the product is used Copying or duplicating this users manual in part or in whole is forbid den The information and specifications in this manual are subject to change without notice Considerable effort has been made to ensure that this manual is free from inaccuracies and omissions If you should find an error or omis sion please contact Yamatake Corporation In no event is Yamatake Corporation liable to anyone for any indirect special or consequential damages as a result of using this product 2006 Yama
16. Setting dialog box is displayed Model select WOVOOD2ee NxOexxx Gas type OS Oxygen OH Hydrogen Control flow range 9200 2 to 200 mL min standard 1000 10 to 1000 L min standard 9500 0 004 to 0 500 L min standard 9005 0 10 to 5 00 mL mintstandard 0002 0 02 to 2 00 L min standard 9020 0 2 to 20 0 mL min standard 0005 0 04 to 5 00 L min standard 9050 0 4 to 50 0 mL min standard 0010 0 10 to 10 00 L mintstandard 0020 0 1 to 20 0 L minstandard 0050 0 4 to 50 0 L min standard 0200 2 to 200 L min standard 0500 4 to 500 L min standard Option 0 None 1 With RS 485 communication function 2 Set the Control flow range and Option 3 Select from the selection items for each setting item 4 Click OK button 18 Chapter 3 SETTING UP THE CMQ V n Handling Precautions e Type set here is the setting for internal use on the loader The model number of the CMQ V will not change even if the type is changed on the loader elf the model number is unknown or not available for selection first go to the step 3 setting up the environment and then return to model number selection After connecting the cable between the personal computer and the CMQ V click the Model read button and the model number will be automatically read out Note e For an explanation of each of the specifications refer to CMQ
17. TING UP THE CMQ V Setup screen Menu bar File Edit Tool bar idea vy Setup data E Instantaneous flow E Parameter setup B Device Information Selection window So Setting Selection ae al Display Communication Setup Option Help 0 Key lock disabled o M RUN key enabled 1 Operation is started up in the ope Eal Valid settings 0 to 2 Display Function setup Key lock RUN key operation and operation mode selection wh ii G Flow rate setup method SP setup method selection C 04 Number of flow set value number of SPs selection Input range selection of analog setup analog SP Analog output type and range selection J Event output 1 type assignment Event output 2 type assignment External 3 way switching function assignment 2 w External contact 1 input function External contact 2 input function assignment 2 w function assignment 2 w when the External contact 3 input Automatic valve shut off totalized flow C 14 On off of totalized flow reset function at start Flow rate alarm setup type Operation selection at alarm occurrence Eoin Slow start setup Gas type selection 1 Temperature at reference conditions Valve amperage alarm setup Address RAM 2001 EEPROM 5001 Message window 16 _ Setup items aj a Digital setup set by key operation or communications o Number of SPs 1 SP 0 only _ 0 to 5 exter
18. aize __ ___ Inilalzesthecellsize Le src with the window CMQ V Series gt MLP R MLP gt CMQ V Series W Environment Setting a Ctrl e flow rate A F C Communication Displays the CMQ V Series user s functions manual for communications Loader Displays the MLP100 user s manual this manual Displays the handling precautions Displays the version informations Information Version A 1 Chapter 3 SETTING UP THE CMQ V 3 2 Setup Procedure Configure setup in offline state without connecting the cable to CMQ V Click the Option on the menu screen Set up in the following steps The following tasks are performed Step 1 Setting up the loader type Step 2 Initialization clearing previous setting values Step 3 Setting up the environment Step 4 Setting up CMQ V parameters Step 5 Saving setup data Step 6 Downloading the setup J Handling Precautions e Operations in steps 1 to 5 are required before the setup parameters are entered on the CMQ V Be sure to perform these steps Otherwise the MPC may be set up incorrectly For example the required setup items may not be displayed or unrequired items may be displayed e Step 6 connects the cable to CMQ V Step 1 setting up the loader type Set up the loader type to match the CMQ V model number 1 Click f icon The operation is the same by selecting the Option Type Setting or the Ctrl t keys gt gt The Type
19. als provided with Windows Click EJ icon at the top right of the screen The operation is the same by selecting the Menu Quit gt gt The MLP is completed Chapter 3 SETTING UP THE CMQ V 3 1 Setup Functions E Overview When the CMQ V is used for the first time it will not function as required unless it is set up by using this setup function The setup function allows you to set the various parameters about 10 to 70 con stants required for operation and write these parameters to the CMQ V so that it functions according to your particular control requirements Parameters such as SP set point and control constants that are changed relatively frequently while the CMQ V is running can also be set from the monitor function screen By the setup function parameters that hardly need changing later once they are set are saved to file in list format before the CMQ V is run and the saved file is called up and written to the CMQ V in a single operation mM Screen explanations Menu screen MLP1004100 Menu Help Setup Monitor MLPIOOA100 1 0 2 C 2006 2009 Yamatake Corporation All Rights Reserved http www yamatake com e Menu configuration list a the Setup window Ctrl s Monitor Displays the Monitor Trend Ctrl m window Changes the environment setup Ctrl e Quits the application Ctrl q Version Displays the version information Ctrl a 15 Chapter 3 SET
20. ayout and the setup procedure MONITORING THE CMQ V OPERATING STATUS This chapter describes monitor functions screen layout and methods of operation relating to communications with a CMQ V Series device TROUBLESHOOTING This chapter describes remedies for problems that may occur while using this software Contents Unpacking The Role of This Manual Organization of This User s Manual Conventions Used in This Manual Chapter 1 1 1 1 2 Chapter 2 Chapter 3 3 1 3 2 Chapter 4 4 1 4 2 Chapter 5 5 1 INTRODUCTION OVEIVICW perar ire EE EA EE ETA EEA EE 1 E Loader functions i b5d 6 cee cls cei sees en oes ees ee we tek savedicanes 1 System Operating Environment eeceececeecceceeceeceeeesenees 2 ACW ANG ooo ie oe oo ooo 6 ho 6S Ko SESS SOR Oe ewe NOE ee eR 2 M Hardware Configuration eee eee cece cece cece cece cess eeeeeccees 2 MEP MSAA 6 36 6 e5dnd iia Eare NEEE IET ce eee thes kent beds ceseneeeeen 3 E MLP installation procedures cccceeeee eee c cece eee eeeeecccees 3 Installing the USB Loader Cable Device Driver sssseeeeeee 7 E Installing the device Criver cccec cece cece cece cece eee eeeeeeeeeeees 7 E Uninstalling the device river cece cece cece cece cece eeeeeeeeees 13 STARTING AND QUITTING THE MLP E Starting the MLP secesyccs ese wersavae wer eee arte seston wesc Ea 14 E Quitling tie MLP esse seca cee eee tre cass neadouen
21. computer and saving them as settings on the CMQ V Monitoring function Operating status or alarm occurrence of the CMQ V can be checked from a person al computer SP flow rate setting or operation mode can be changed during moni toring The operating status can be sampled and viewed as a graph and the sampled data can be output in CSV format so that it can be handled in third party spread sheet software such as Microsoft Excel The run state can also be checked on the Trend screen and sampled data can be output in CSV format so that it can be handled in third party spreadsheet software such as Microsoft Excel 1 Handling Precautions e The monitor target is limited to only one unit when the loader jack on the side is used for performing monitoring Chapter 1 INTRODUCTION 1 2 System Operating Environment The following system environment is required for using the loader E Hardware Personal Computer Target model PC AT compatibles with a Pentium chip or higher 32M byte or more Operating system Windows2000 Professional XP Home XP Professional Vista 32 bits USB Port 1 port or more Use USB loader cable E Hardware configuration General configuration connected with USB loader cable Communications c AAA lt Q aeee ea OOO RRA cere FOE PD EERE EFS OF a YG Configuration with RS 485 CMQ V with RS 485 communications function only If multiple CMQ V units max 31 with RS
22. count 60 000 fixed regardless of number of data items to sample Note e A CSV file is the data format that can be handled in third party spreadsheet software such as Microsoft Excel In this format sampled trend data can be interpreted in spreadsheet software These screens can be used to perform the following operations e Monitoring of operating status and changing of various parameters on the Numeric Monitor e Switching of the operation mode on the Numeric Monitor e Monitoring of trends and sampling of data while the CMQ V is operating e Monitoring of alarms on the Numeric Monitor L Handling Precautions 22 e About connection to the personal computer When making the setup or operating the monitor using the loader con nect the loader cable e Before starting the trend monitor configure the settings suitable for the trend monitor e The sampling cycle sometimes shifts due to fluctuations in the communi cations cycle To perform measurement at exact times use the special recorder or data logger mM Screen explanations Numeric monitor screen Chapter 4 MONITORING THE CMQ V OPERATING STATUS F MLP100 Monitor Screen Numeric Monitor OFF Trend Monitor OFF File Numeric Monitor M Option O Trend Monitor T Help Hox Bass Numeric Monitor Alarm Event External 3 way switching External switch OK lamp Slow start Digital Analog Integralation count value SP ramp control Numeric Monito
23. ear by repetitious open close operations In addition electronic components such as electrolytic capacitors will reach the end of their life due to aged deterioration based on the conditions or environment in which such electronic components are used Although acceleration of the above situation varies depending on the conditions or environment of use the number of open close operations of relays etc as prescribed in specifications or instruction manuals or depending on the design margin of your machine or equipment you are required to renew any Yamatake products every 5 to 10 years unless otherwise specified in specifications or instruction manuals Field instruments Sensors such as pressure flow level sensors regulating valves etc will reach the end of their life due to aged deterioration of parts For those parts that will reach the end of their life due to aged deterioration recommended replacement cycles are prescribed You are required to replace parts based on such recommended replacement cycles 6 Other precautions Prior to your use of Yamatake products you are required to understand and comply with specifications e g conditions and environment of use precautions warnings cautions notices as set forth in the technical documents prepared for individual Yamatake products such as catalogs specifications and instruction manuals to ensure the quality reliability and safety of those products 7 Changes to specifications Please
24. ected The CMQ V is not connected Connect the loader to the CMQ V Power is not being supplied to Supply power to the CMQ V Cannot open communications The communications port cannot Do not run the loader and other port software that uses the communications port at the same time A communications error has A system error occurred Try again or quit the loader to occurred Restart Windows restart Windows or Check the connected There is a discrepancy in the Check the communications setup instrument communications setup Check the cable connections and contacts The CMQ V is not connected Supply power to the CMQ V CMQ V Cannot support currently Wrong loader version for this Contact Yamatake Corporation status error connected CMQ V CMQ V model or its dealer Flow range or gas type Mismatch of model numbers Click Read model on the mismatch between CMQ V and model selection screen to read loader Upload stopped out the CMQ V model No Parameter settings exceeded Attempt to write data that After reading out the data from range Some data possibly not exceeded the allowable range the CMQ V review the For example flow range or gas parameter settings type accidentally changed by external contact of the CMQ V 31 Chapter 5 TROUBLESHOOTING E File error messages Category File name This filename is not valid An invalid file name is input Input a correct file name error This file cannot be found A
25. er name and company name and then click the Next gt button gt gt The following screen appears 2 Display Registration Information This software has already been installed by the following person Ifyou are not licensed to use this software you may not install this software onto your computer 5 Click Next gt button gt gt The following screen appears Choose Destination Location Setup will install MLP100A100 in the following folder To install into a different folder click Browse and select another folder You can choose not to install MLP100A100 by clicking Cancel to exit Setup Note e To change the installation destination directory click Browse button Chapter 1 INTRODUCTION 6 Click Next gt button gt gt The following screen appears Select Components In the options list below select the checkboxes for the options that you would like to have installed The disk space fields reflect the requirements of the options you have selected M Sample program C Builder M Sample program F BASIC POF filefjapanese M PDF file english Disk Space Required 151k Disk Space Remaining 14736708 k lt Back Cancel Note e Check the necessary files To display a PDF file Adobe Reader is required If Adobe Reader is not already installed on your PC download it from the Adobe Systems webpage 7 Check on put a check mark W software components you wi
26. ermareeaaneneceses 14 SETTING UP THE CMQ V Setup FUNCHONS serrrrreirir troir tant eerste ese saceee arenes never esens a8 15 Me OOM CI VIEW oe E E E eh i heh esha ie tee wadesce nese octets bsaeesedaeeeee 15 M Screen explanations sessessssssssssosssoosesossrossssocsesoes 15 Set p PIOCEGUIE oxcse eves nvasss tin erna cpewinrrineh iene reyeeeeenunssetinks 18 MONITORING THE CMQ V OPERATIING STATUS Monitoring FUNCTION s e ssessssessssesssoesesessooesssossosesesoeseoe 22 E OvervieW a aso ois oe 5 ow ah he eed O44 e e a se 22 M Screen explanations ccccccceee cece ccc ceseeeeeeeecesseeeeeees 23 Method of Operation c cece cc ccc cece ccc cese sec csee nec ssesnecssesnes 26 E How to operate the numeric monitor screen e eee eee wees 26 E How to operate the trend monitor cece eee eee cece reece eeceees 28 TROUBLESHOOTING Error Messages essssssssssessscoesesocoseesoooseesososesssoceeesseoe 31 M Setup error messages ssssessesssossoesesesoesosesoeseseseeees 31 E Communications error messages es essssossesessossoseosees 31 E File error messages esesesseooseesecosecssooceeesocoesesecoee 32 Other Troubleshooting sessessssssosssessossosssesssesosssossoessos 33 iil Conventions Used in This Manual The following conventions are used in this manual C Handling Precautions Note 1 2 3 OK button Option Handling Precautions i
27. et Loader cable RS 485 to RS 485 The controller is then connected through the CMC10L At this time the environment setting and communication setup on the CMQ V main unit must be adjusted beforehand Additionally configure the settings on the CMQ V in the offline mode the cable is not connected to the CMQ V For details refer to CMQ V Series Digital Mass Flow Controller Communications No CP SP 1197E Chapter 3 SETTING UP THE CMQ V Step 5 saving setup data When you have finished making the settings save the setup Saving setups in advance and using saved setups greatly reduces the time and load when setting up the loader The following items are saved Type e Setup parameters 1 The operation is the same by selecting the File gt Save As or Ctrl a keys gt gt The Save As dialog box appears Save As Seve To My eBooks Bm Music E My Pictures Fa pane Save as lype MLP1004100file mit v 2 Enter the file name and click Save button Step 6 downloading the setup Write the set parameters or parameters called up from a saved file to the CMQ V 1 Use the special loader cable to connect the personal computer to the CMQ V body 2 Turn the CMQ V ON 3 Click i icon The operation is the same by selecting Communication Write MLP CMQ V Series in the pull down menu gt gt The message Writing is going to be executed is displayed 4 Click OK button gt
28. etup Analog trend mDigital trend BJ 8707 B BC Bo Soe OCR Sle Bl set flowrate Default control flowrate valve drive output When each button is selected the color selection screen will appear Select a desired color Chapter 4 MONITORING THE CMQ V OPERATING STATUS Clicking Default will return the color setting to its initial value Custom colors BEE EEE g BEE EEE Ee e Trend trigger setup File Graph setup Trend monitor color setup Trend trigger setup rOn trigger Of trigger Save trigger O 0 None 0 0 None O 7 Mode Control mode O F Mode Control mode O 7 ModefControl mode 8 Mode Fully open 8 Mode Fully open 8 Mode Fully open Og Alarm O3 Alarm O3 Alarm 10 0K lamp 10 0K lamp 10 0K lamp 11 E 4 reverse 11 E 1 reverse 11 EV1 reverse 12 EV2 reverse 12 EV2 reverse 12 EV2 reverse 13 D11 reverse 13 D11 reverse O 13 D11 reverse 14 Dl2 reverse 14 Dl2 reverse 14 Dl2 reverse 15 DI3 reverse 15 DI3 reverse 16 DI3 reverse 16 Mode Fully closed reverse 16 Mode Fully closed reverse O 16 Mode Fully clased reverse 17 Mode Control mode freverse 17 Mode Control mode reverse O 17 Mode Control mode reverse 18 Mode Fully open reverse 18 Mode Fully open reverse 18 Mode Fully open reverse 19 Alarm reverse 19 Alarm reverse 19 Alarm
29. file name not existing is input Input an existing file name Make sure that the correct path and filename are given This filename is a reserved A file name reserved for the Input a correct file name device name device name is input Use a different filename Disk error Not enough free space on disk The disk free capacity is Keep a sufficient disk free insufficient Capacity The device is not ready The disk is not ready Prepare the disk and restart the operation Cannot make file The CD ROM is specified as Save the file to another directory save destination File name too long The file name is too long Use 255 characters or less for the file name Pass name The path does not exist An illegal path name is input Input a correct path name and error Make sure that the correct path restart the operation is given File information Illegal file size The file is corrupted Corrupted file cannot be used error Illegal file information Create a file again 32 Chapter 5 TROUBLESHOOTING 5 2 Other Troubleshooting Numeric values are not If a decimal point symbol other than Check that the decimal point displayed correctly period is set the loader does not function symbol is period If not set correctly the cdecimal point symbol to period Note e period should be set as the decimal separating symbol in the Windows con trol panel Example for Windows XP go to Control Panel Date
30. freverse 20 0K larnptreverse 20 0K larnp reverse 20 0K lamptreverse Stop delay Save folder CAProgram Files rnlp MLP100 CJ Trend triqgeris only in numeric monitor mode When setting up the trend triggers the trend can be started and stopped accord ing to the status of the numeric monitor The trend trigger setup is valid only while the numeric monitor is running When setting up the trend save triggers the trend can be saved according to the status of the numeric monitor The file is saved into a specified trend save folder in the TREND YYYY MM DD HH MM SS CSV format Starting the data sampling After completion of setup click the tat icon The same operation can be started by selecting Trend Monitor gt Trend Monitor Start gt gt The data sampling is started and then the trend of the specified parameters is displayed on the screen e Once the trend monitor is started it continues until the stop operation is per formed or the data for 60 000 cycles is sampled e If the stop operation is not performed the data is overwritten onto the old data when the data sampling for 60 000 cycles is completed e The screen can be transited to the Numeric Monitor screen while the trend monitor is running However the loader cannot be quitted or the screen can not be transited to the Setup screen To do so quit the trend monitor Note e If the check mark r on the left of t
31. h for software O Yes this time only Yes now and every time connect a device Click Next to continue Chapter 1 INTRODUCTION 2 For the retrieval location of the device driver to be installed select the No not this time and click the Next gt button Found New Hardware Wizard This wizard helps you install software for USB Serial Controller 9 E your hardware came with an installation CD or floppy disk insert it now What do you want the wizard to do Install from a list or specific location Advanced Click Next to continue gt gt Retrieval of the device driver starts Found New Hardware Wizard gt gt When the device driver is found the following window appears Hardware Installation The software you are installing for this hardware Yamatake USB Loader Comm port has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair correct Seat dbeok as vende Saati eee a passed Windows Logo testing 10 Chapter 1 INTRODUCTION 3 Click Continue Anyway gt gt Installation of the device driver starts Found New Hardware Wizard Please wait while the wizard installs the software F Yamatake USB Loader Comm port fi Yeslip sys To C WINDOWS system32 DRIVERS gt gt When the device driver installation is complete the following
32. he item at the bottom of screen is removed the graph for that item is not displayed 29 Chapter 4 MONITORING THE CMQ V OPERATING STATUS Stopping the data sampling Select Trend monitor Trend monitor Stop The trend monitor is then stopped Saving sampled data The data sampled using the trend monitor can be saved to a file in CSV format The sampled data saved in CSV format can be processed using spreadsheet applica tions such as Microsoft Excel 1 Handling Precautions e The data can be saved to a file even while the trend monitor is run ning e Saved data remains on the screen or on the personal computer until some operation replaces it The saved data can be read by selecting Trend monitor gt CSV Read It also can be read using spreadsheet software Saving clipboard graph output Contents displayed on the Trend Monitor such as SP value PV value and valve amperage can be directly saved to the clipboard in the form of a screenshot 30 Chapter 5 TROUBLESHOOTING 5 1 Error Messages E Setup error messages Category Cannot run multiple instances Multiple instances of the MLP Click OK button of the MLP at the same time program were started at the same time E Communications error messages Category Communi Timed out Message was not received Check the cable contacts cations before the time out time connections and contacts error A device other than the CMQ V is conn
33. ho belongs to the administrator group The USB loader cable is supported on Windows 2000 XP Vista 32 bit type It is not supported on 64 bit Windows XP or on Windows 95 Windows NT MS DOS or PC DOS e fthere are multiple USB ports connect the USB loader cable to the same port every time If it is connected to a different port there is a chance that driver installation may be required again 1 Put the SLP CD ROM into the CD ROM drive of the personal computer gt gt The installation program is then started up automatically and the following screen appears MLP install O Before installing the driver digconmect the USB connector Install USB loader cable driver Install MLP E Please select install program 1 Click the Install USB loader cable driver button gt gt The following screen appears Yamatake USB Loader Cable Driver Installer Welcome to the USB Loader Cable Driver Installer This wizard will walk you through updating the drivers for your Yamatake USB device To continue click Next Cancel Chapter 1 INTRODUCTION 2 Click the Next gt button gt gt The following screen appears Yamatake USB Loader Cable Driver Installer End User License Agreement lt Back J __ Next gt J Cancel 3 Select AGREE and click the Next gt button gt gt The following screen appears Yamatake USB Loader Cable Driver Installer Installing the software for your Toaster device
34. lowed For details refer to CMQ V Series Digital Mass Flow Controller User s Manual No CP SP 1204E or CMQ V Series Digital Mass Flow Controller for Hydrogen and Helium Gases User s Manual No CP SP 1205E Use of the command line Data can be read or written or the mode switched by directly entering communica tions commands on the command line 1 Handling Precautions e Use of the command line is not generally required and sending an erroneous command can cause problems For instructions on setting the command type address data etc contact Yamatake Corporation e For details on communications commands and data addresses refer to CMQ V Series Digital Mass Flow Controller Communications No CP SP 1197E Checking details of alarms You can check the details of alarms in the Alarm window when an alarm occurs e Click E icon The operation is the same by selecting the Option Q Alarm A e The details of the alarm that is occurring are displayed Handling Precautions e This window displays the details of currently occurring alarms and does not have a function for restoring the CMQ V To restore the CMQ V you must perform the appropriate remedy described in CMQ V Series Digital Mass Flow Controller User s Manual No CP SP 1204E or CMQ V Series Digital Mass Flow Controller for Hydrogen and Helium Gases User s Manual No CP SP 1205E 27 Chapter 4 MONITORING THE CMQ V OPERATING STATUS E How to opera
35. mouse from the lower right portion to the upper left portion with the left mouse button kept pressed Eile Trend monitor Option Numeric Monitor Help ESHER Madr AADA 20 19 18 LRA er 164 oa eile 104 00 00 00 00 00 00 aM Pv M valve MokKlamp Mew Mev2 g oMpr omn MEx3INPUT 25 Chapter 4 MONITORING THE CMQ V OPERATING STATUS 4 2 Method of Operation E How to operate the numeric monitor screen Start of monitoring start of communications The operation described below is required to start monitoring Otherwise monitoring and rewriting of data cannot be performed e Click FE icon The operation is the same by selecting Numeric Monitor Numeric Monitor Start gt gt During normal operation The data on the CMQ V is displayed During an error The message Check the device to which the loader is connected is displayed Remedy according to Chapter 5 TROUBLESHOOTING The following operations are possible when the device and the loader are correctly connected Monitoring of operation state and changing of parameters Operation mode Numeric monitor displayed in table format Numeric group monitor State monitor displayed in lamp lighting format L Handling Precautions 0 Valve fully closed 1 Valve control 2 Valve
36. nal reference input 0 to 5 instantaneous flow rate output Not used OFF at all times Not used OFF at all times Not used Not Not Not used used used Function disabled Function disabled _ oo o oo o oe o Upper lower limit alarm used Control continued and alarm output ON Slow start disabled Air nitrogen 20 C 1 atmosphere Valve amperage alarm disabled Chapter 3 SETTING UP THE CMQ V Menu configuration list Menu File Edit Display Communicatio Setup Option D D SaveAs fe Saves the active data with name Ctrl a po CSV Out X Pe Saves the active data in CSV format Ctrl x ATC out __ Savesthe active detain HTML format Cirith rr Prints the active data with same a contents as HTML output a Five most recent files Function setup B Displays or sets the function setup Ctrl Shift b Parameter setup Displays or sets the parameter setup Ctrl Shift c Device Information Displays the device related data Ctrl Shift d PDF Installation and Displays the CMQ V Series user s F1 Configuration manual fon f o Quits the apicatn S oa Data Check Checks aliseting values Orima Parameter disparea ___ Displays tne parameter display area intenable pispaysmenm Auiosize Makes the auto cellsize enabled Sizeint
37. ndicate items that the user should pay attention to when handling the MLP100 Notes indicate useful information that the user might benefit by knowing The numbers with the parenthesis indicate steps in a sequence or indicate corresponding parts in an explanation Indicates a selection button in screens displayed on the personal computer Indicates messages and menus displayed on the personal computer Option Type Setting gt gt Ctrl key a key Ctrl a key Indicates the order to select the Option first and then select the Type Setting displayed on the personal computer Indicates the result of an operation details displayed on the personal computer or devices or the state of a device after an operation Indicates keys on the keyboard Indicates the operation of pressing the a key with the Ctrl key on the keyboard held down Chapter 1 INTRODUCTION 1 1 Overview The MLP100 or simply the MLP is a software program for setting various parameters and monitoring the oper ating state of a CMQ V Series Digital Mass Flow Controller simply CMQ V from here on on a personal com puter The MLP runs on Windows2000 XP Vista simply called Windows from here on on a personal computer E Loader functions The MLP has the following functions e Setup e Monitor Setup function This function is for inputting various parameters required for the operation of the CMQ V into a personal
38. nge Remove button Uninstall Driver Package 2 All devices using this driver will be removed Do you wish to continue 2 Click the Yes button 3 Restart the computer 13 Chapter 2 STARTING AND QUITTING THE MLP o Handling Precautions E Starting the MLP E Quitting the MLP 14 e Before starting up the MLP quit all other applications If you start up loader while another application is running the MLP may not function Also set the power save setting infrared communications and screen saver to OFF e Make sure that the Decimal symbol has been set to for Control Panel Regional Settings Number If it has been set to some other character the loader program cannot function correctly Example for Windows XP go to Control Panel Date Time Language and Regional Options Regional and Language Options Regional Options Customize Decimal symbol Select and click OK button Double click the MLP100A100 icon on the desk top or click Start button at the lower portion of the screen and select Programs gt MLP gt MLP100A100 gt gt The MLP is started up and the menu window is displayed 2 MLP100A100 ba ol Setup Monitor MLPIOOA100 1 0 2 C 2006 2009 Yamatake Corporation All Rights Reserved http www yamatake com Note e For the operating system details and the mouse setup refer to User s Manu
39. r Operation mode Instantaneous SP No in use Instantaneous SP value in use Instantaneous P value Valve actuation current Digital instantaneous flowrate SP O Digital instantaneous flowrate SP 1 Digital instantaneous flowrate SP 2 Digital instantaneous flowrate SP 3 Digital instantaneous flowrate SP 64 Digital instantaneous flowrate SP 6 Digital instantaneous flowrate SP 7 Digital instantaneous flowrate SP 8 Integrated SP flowrate Integrated PY flowrate e Menu configuration list Numeric Numeric Monitor Starts stops the monitor Ctrl m Monitor M EEI Start Stop M Option O Reset integrated Resets the integrated flowrate flow rate R Alarm A Displays the Alarm Details window a KI Command Line C Displays the Command Line Ei window Changes the display to the trend Trend Monitor T monitor Displays the version information 23 24 Chapter 4 MONITORING THE CMQ V OPERATING STATUS Trend monitor screen ej Trend monitor File Trend monitor Option Numeric Monitor Help Es a4 gt gt QD AUM 20 19 18 17 16 15 14 13 12 11 10 00 00 00 00 00 00 M SP1 MP M Valvet v Alarm V OK lamp B V Ev1 B V Ev2 omon oM DI opis V Ext3INPUT e Menu configuration list Trend Pr Trend monitor Starts stops the trend monitor Ctrl t monitor Start Stop T
40. rol valves and control products unless otherwise stated in any separate document including without limitation estimation sheets written agreements catalogs specifications and instruction manuals 1 Warranty period and warranty scope 1 1 Warranty period Yamatake products shall be warranted for one 1 year from the date of your purchase of the said products or the delivery of the said products to a place designated by you 1 2 Warranty scope In the event that Yamatake product has any failure attributable to Yamatake during the aforementioned warranty period Yamatake shall without charge deliver a replacement for the said product to the place where you purchased or repair the said product and deliver it to the aforementioned place Notwithstanding the foregoing any failure falling under one of the following shall not be covered under this warranty 1 Failure caused by your improper use of Yamatake product noncompliance with conditions environment of use precautions etc set forth in catalogs specifications instruction manuals etc 2 Failure caused for other reasons than Yamatake product 3 Failure caused by any modification or repair made by any person other than Yamatake or Yamatake s subcontractors 4 Failure caused by your use of Yamatake product in a manner not conforming to the intended usage of that product 5 Failure that the state of the art at the time of Yamatake s shipment did not allow Yamatake to predict or
41. sh to install and click Next gt button gt gt The following screen appears 2 Select Start Menu Group Enter the name ofthe Start Menu group to add MLP100A100 icons to Accessories Administrative Tools Cancel Note e To change the program folder enter the new folder name 8 Click Next gt button gt gt The following screen appears Start Installation You are now ready to install MLP100A100 Press the Next button to begin the installation or the Back button to reenter the installation information Cancel Chapter 1 INTRODUCTION 9 Click Next gt button gt gt The following screen appears s5 Installation Complete 10 Click Finish gt button gt gt When the installation is completed successfully the screen will return to the Windows screen Chapter 1 INTRODUCTION 1 4 Installing the USB Loader Cable Device Driver A device driver must be installed before using the USB loader cable Follow the procedure below to install the device driver E Installing the device driver L Handling Precautions e Be sure to follow the procedure below when installing the device driver The USB cable may not be recognized if the procedure is not followed If the cable is not recognized uninstall the driver and then install it again e Administrator privileges on the computer are required for driver installa tion Installation should be done by the administrator or by a user w
42. take Corporation ALL RIGHTS RESERVED Micro Flow uF and CMQ are trademarks of Yamatake Corporation The Role of This Manual In all four manuals have been prepared for the CMQ V Series Read the manual according to your specific require ments The following lists all the manuals that accompany the CMQ V Series and gives a brief outline of the manual If you do not have the required manual contact Yamatake Corporation or your dealer CMQ V Series Digital Mass Flow Controller Manual No CP SP 1204E First time users of the CMQ V Series and those in charge of maintenance or hardware design for incorporating a CMQ V Series controller in instru mentation should read this manual This manual outlines the product tells how to install wire and incorporate the product into instrumentation and describes its operation inspection and maintenance troubleshooting and hardware specifications CMQ V Series Digital Mass Flow Controller for Hydrogen and Helium Gases Manual No CP SP 1205E First time users of the CMQ V Series for hydrogen and helium gases and those in charge of maintenance or hardware design for incorporating a CMQ V Series controller For hydrogen and helium gases in instrumenta tion should read this manual This manual outlines the product tells how to install wire and incorporate the product into instrumentation and describes its operation inspection and maintenance troubleshooting and
43. te the trend monitor Setup 28 Select Graph setup Station address setup Trend monitor color setup and Trend trigger setup at Option Q Setup and make the settings below for each sampled data As the cycle and display upper lower limits are common to all channels e Graph setup left axis is flow rate right axis is valve amperage Setting item Setting range Factory setting Cycle Setting of sampling cycle 1 to 3600s Display low limit Lower value of left vertical 1999 to display upper of left axis axis of screen display limit Display high limit Upper value of left vertical Display lower limit to 20 of left axis axis of screen display 9999 Display low limit Lower value of right vertical 1999 to display upper 10 of right axis axis of screen display limit Display high limit Upper value of right vertical Display lower limit to 110 of right axis axis of screen display 9999 1 Handling Precautions e Be sure to change the sampling cycle setting only when trend monitor ing is stopped e Station address setup only for RS 485 communications Setting item Setting range setting Station address to Sets the station 0 Not used which the data is address 1 to 127 Station address transmitted Station subaddress orea o o Handling Precautions e Can be set only if 1 RS 485 is selected for Loader cable RS 485 at step 3 Setting up the environment on page 18 e Trend monitor color s
44. tom Transportation equipment Railway aircraft vessels vehicle equipment etc Antidisaster crime prevention equipment Burning appliances Electrothermal equipment Amusement facilities 3 Supply systems such as electricity gas water supply systems large scale communication systems and traffic air traffic control systems requiring high reliability 4 Facilities that are to comply with regulations of governmental public agencies or specific industries 5 Machinery or equipment that may affect human lives human bodies or properties 6 Other machinery or equipment equivalent to those set forth in items 1 to 5 above which require high reliability and safety 4 Precautions against long term use Use of Yamatake products including switches which contain electronic components over a prolonged period may degrade insulation or increase contact resistance and may result in heat generation or any other similar problem causing such product or switch to develop safety hazards such as smoking ignition and electrification Although acceleration of the above situation varies depending on the conditions or environment of use of the products you are required not to use any Yamatake products for a period exceeding ten 10 years unless otherwise stated in specifications or instruction manuals 5 Recommendation for renewal Mechanical components such as relays and switches used for Yamatake products will reach the end of their life due to w
45. tton to complete the configuration Evronnent Selime Eg Communication setup TT Font size Port Loader cable RS 48 j address Speed O7 coN Ocona 1 al 0 38400bps Ocon Oconto 1 19200bps O 8 Ocows Ocowi _ sub add 2 9800bps 0 Loader cable Ocom Ocome O1 RS 485 o S piai i O cons O com cone con14 Communications conditions O con cont 0 8 data bits even parity 1 stop bit O cone com16 1 8 data bits no parity 2 stop bits 4 2400bps Gi O11 Fixed Cell Width Note e When the USB loader cable auto select button is clicked port selection can be done automatically Note e Ifthe CD ROM for the MLP is not available execute drvsetup exe on the computer on which the MLP is installed Then install the device driver Normally C Program Files mlp MLP 100 12 Chapter 1 INTRODUCTION E Uninstalling the device driver J Handling Precautions e Removing the driver requires restarting the computer Close other applications first and then uninstall the driver e To uninstall the driver administrator rights are required on the computer Uninstalling should be done by the administrator or by a user who belongs to the administrator group 1 Execute the driver removal program 1 Go to Control Panel gt Add or Remove Programs and click on Windows Driver Package Yamatake YC slp USB 04 19 2007 1 0 0 Click the Cha
Download Pdf Manuals
Related Search
Related Contents
USER MANUAL YF3ー 532K YF3ー 534K Salton MESC10 User's Manual Noviembre de 2012 Hydrosteel 7000 Manual V3.1 Fisher-Price J6998 Baby Monitor User Manual User Manual Digital Voice Recorder ディジタル圧力計MT210/MT210F 仕様 Sterling Power Products 30F User's Manual Copyright © All rights reserved.
Failed to retrieve file