Home
        User manual - Autoplugin
         Contents
1.  or turning the ignition to    on    position enables  CIP timers again     Additional Functions    By default RCP adjusted to perform only basic functions  such as start and  stop of the heater using the remote control key  To turn on the additional functions  such as battery monitoring  flashing with direction indicators in rearview mirrors   etc  enter the module into Setup mode and activate corresponding setup item  see  settings table 3     The buttons of the left hand stalk switch and the brakes pedal are used to  enter Setup mode and to change the settings  It is necessary to stop the engine and  the heater before  Turn the ignition on by holding engine start button for at least 2  seconds  then press and hold the brakes pedal  Rotate the thumbwheel some steps  to select idle display in the CIP  Then press and hold for at least 5 seconds    Read     button     OK    button in some cars   while module   s LED flashes once a second   Both direction indicators in the CIP confirm entering to the setup mode with 2  flashes   Release the brakes pedal and    Read OK    button finally    Each setup item in the settings table is a 3 digit code  To enter a digit of a  code  shortly press    RESET    button so much times  as corresponds to a digit  The  LED and the direction indicators symbols in the CIP confirm each button press  the  LED briefly goes off  the left direction indicator flashes one time when the first or  the third digit of code is entered  the right direction ind
2. 6 1 2 Five flashes  with 6 2  Indication of 6 2 1  Off  direction command reception   6 2 2 Three flashes    indicators in  the rearview  mirrors    from a remote  control       6 3  Indication of  the heater   s  operation  when  starting source is  the remote control    6 3 1  Off  6 3 2 On       6 4  Indication of  the heater   s  operation  when  starting source is  the CIP  direct or  timer start     6 4 1  Off  6 4 2 On          8   Service  menu       8 1  Default Settings       8 1 1 Apply factory settings         Factory setting  Recommended settings marked in Italics     _The module turns off the heater if battery  s voltage lowers to the adjusted limit       Troubleshooting    If a run time error occurs during the heater   s operation  Autoplugin Key informs  about the error code with LED flashing  The number of flashes corresponds to the  error code  See table 2 for the error   s description and possible solutions                       Table 2  Error Error Possible Reasons of Solutions  Code   Description Error Appearance  2 No answer Outer temperature is The heater operates only at  from the higher than  15 Celsius   temperatures below  15  C  It  heater degrees is the heater manufacturer s  followed the restriction  start Fuel level in the fuel Refuel the vehicle  command tank is close to empty      Fuel Low    warning  indicator is illuminated  in the CIP   The heater is blocked Try to start the heater in the  after 3 unsuccessful CIP menu  If it doesn   t star
3. Autoplugin Key V3    Version 9 1    User Manual    Rev  A    Table of Contents    Deserplion usas radon ta s Bp B tn an a dou eee ee   Module    s Possibilities dd eek   Package Contents sat tio toda  CONNECTION  sr ld ies pida  Basto Function see A oo op  Additional Functions a ee aa ee nee  A cates load tebe tase ates s es    Glossary    CAN   Control Area Network  digital network for data transfer in vehicles   CIP   Combined Instrument Panel  PCC     Personal Car Communicator    Description    The Autoplugin Key V3 is electronic module designed to add a remote control  ability to the fuel fired heater  parking heater  fuel operated heater  pre heater    factory installed in Volvo C30  200  2013   S40  200  2012   V50  200  2012  or  C70  200  2013   The device is plugged into the OBD II service connector  placed  on the dashboard  and controls the heater via CAN bus     Module   s Possibilities    e Immediate start of the heater with Volvo car   s key  The remote control  key with 5 buttons or the PCC with 6 buttons can be used for the heater  control   e Immediate stop of the heater with Volvo car   s key   e Indication of heater   s autonomous operation with the direction indicators  flashing in the rearview mirrors    e Additional protection of the main battery from discharging inspecting  voltage level and time of autonomous operation of the heater    Package Content    1  Autoplugin Key V3 cartridge  2  User Manual brochure    Connection    The module needs that 2 ti
4. icator   when the second  digit of code is entered  To complete a digit entering  press and release    Read OK     button  The CIP confirms it with one flash of both direction indicators  simultaneously  When all three digits entered  the module checks the code for  validity and confirms it with the direction indicators flashing  The both direction  indicators flash twice simultaneously in case of valid code and flash twice  alternately in case of invalid code     5    If entered digit is not correct  press and release    Read OK    button until the module  indicates an error  Enter the code once more in that case  Several codes can be    entered without exit of setup mode     Turn the ignition off to exit setup mode  New settings are saved in the nonvolatile  memory of the module and stored there regardless of whether the module is  connected or not  Note  If you start the engine without exit Setup mode  new    settings will not be saved in memory     To reset the module to the factory settings  enter the code 8 1 1  Both direction  indicators in the CIP should flash three times  confirming command execution   Then the module exits Setup mode and restarts                    Settings table  1   Settings Settings Possible Values  Group Item  1  1 1  Limitation of 1 1 1  Not adjusted  Heater   s heater   s total 1 1 2 40 minutes  operation operational time in  1 1 3 50 minutes  time pre heat mode 1 1 4 60 minutes  1 1 5 70 minutes  1 1 6 80 minutes  1 1 7 90 minutes  1 1 8 100 
5. mers and direct start   stop function for the heater  control are present in CIP  Therefore it may be necessary to load the special  software to the CIP at first by the means of Volvo dealer   s equipment     Autoplugin Key does not need professional installation  Find OBD II service  connector at the left lower point of the dashboard  The connector is placed near to  the handle for bonnet opening  Take the module to your hand with the LED   oriented closer to the driver   s door side  and then gently push it to the OBD II  connector  LED starts flashing for approximately 10 seconds  waiting for  information from CAN bus  Wait until the LED stops flashing before the  operation  Turn the ignition on if the LED continues flashing after 10 seconds  expired     Basic Functions    1  A special combination of buttons    presses is used to start the heater with the  remote control key  Firstly press    Lamp    button on the key to switch on the  car   s lighting  Then press    Lock    button twice within 30 seconds  while  lighting is on  Every    Lock    button   s pressing is confirmed with direction  indicators flashing    2  To stop the heater with the remote control key  switch on and then switch off  car   s lighting twice  Intervals between    Lamp    button presses should not  exceed 20 seconds    3  It is possible remotely disable startups of the heater  programmed in the CIP   Use remote control key to send stop command when the heater is idle   Starting the heater any way
6. minutes  1 1 9 120 minutes  1 2  Limitation of 1 2 1 10 minutes  heater   s 1 cycle 1 2 2 15 minutes  operational time in  1 2 3 20 minutes  pre heat mode 1 2 4 25 minutes  1 2 5 30 minutes  1 2 6 40 minutes  1 2 7 50 minutes  1 2 8 60 minutes  1 2 9  70 minutes  2  2 1     Lock    and 2 1 1     Lock    button for the heater start   Heater    Lamp    buttons       Lamp    button for the heater stop  control with   functions for the 2 1 2    Lamp    button for the heater start   remote heater control    Lock    button for the heater stop  control key                2 2  Number of 2 2 1 Combination is disabled  sequential    Lamp     2 2 2  Four presses   button presses for 2 2 3 Six presses   the heater control 2 2 4 Eight presses   2 3  Number of 2 3 1 Combination is disabled  sequential    Lock    2 3 2  Two presses   button presses for 2 3 3 Three presses          6       the heater control   with the car   s  lighting turned on     2 3 4 Four presses                3  3 1  3 1 1   Not adjusted  Battery Minimal battery 3 1 2 11 8V  Monitoring   voltage that lets the   3 1 3 11 8V  module start the 3 1 4 11 9V  heater in pre heat 3 1 5 12 0V  mode 3 1 6 12 1V  3 1 7 12 2V  3 1 8 12 3V  3 1 9 12 4V  3 2  3 2 1   Not adjusted  Minimal battery 3 2 2 11 4V  voltage that lets the  3 2 3 11 5V  module keep 3 2 4 11 6V  operating the heater   3 2 5 11 7V  in pre heat mode   3 2 6 11 8V  3 2 7 11 9V  3 2 8 12 0V  6  6 1  Indication of 6 1 1  Off  Indication the heater   s startup   
7. t  starts up  make diagnostics of the  heater    3 Battery low The module has Charge vehicle   s battery with  determined that the special charger  or start engine  battery   s voltage is to charge  or cancel 3 1 3 2  below the specified by module   s settings  settings items 3 1 or 3 2   4 Time limits Time limit for Run the engine or cancel 1 1                      exceeded autonomous operation of   module   s settings  the heater is achieved  5 Unsuccessful   The heater was switched   Make diagnostics of the heater  start off spontaneously at if the error appears again  starting  6 Operation The heater was switched   Make diagnostics of the heater  cycle too off spontaneously if the error appears again  short  8 CAN bus There is a problem with   Check for the module   s  error module   s connection to   connection  the CAN bus  9 Settings error   Settings have been Reset the settings  8 1 1    stored in the module   s readjust the module  memory incorrectly  11   Heater no The heater is unplugged   Make diagnostics of the heater       connection       or out of order                Autoplugin ES www autoplugin ru    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
よくある質問(FAQ)  趣警告  ゼルダの伝説 ふしぎのぼうし  COMISIÓN EUROPEA Bruselas, 25.4.2013 COM(2013) 232 final  Samsung DVD-H1080R User Manual  Manhattan 161220  全ページ一括表示  1 - Husky Power Washer, Home Depot Pressure Washer  Installation and programming guide  東京商工リサーチ TSR情報2007 9.5 No.2034号の記事    Copyright © All rights reserved. 
   Failed to retrieve file