1. ENGLISH DISPLAY APPLIANCES CONTROL amp ALARM SYSTEM SYSTEM USER SPECIFICATION Thank you for choosing our panel Please read this manual carefully before using it Table of Contents 1 Features 2 2 Main panel Sketch Map 3 3 System installation 4 4 System Setup 5 5 System Usage 7 6 System Main Parameters 9 7 Whole Kit List 10 8 Storage Transportation 10 Features 1 Chromatic back light English screen in main panel straight setting and inquiring 2 Operating interface show the information such as defense area location detector style alarm phone number password date etc 3 All function set keyboard let user finish setting in panel 4 Long distance tone indicating remote control easily 5 Eight wireless and seven wired defense zones be provided with strong programming function for defense zones 6 Arming away mode and arming stay mode whatever for use in home or out 7 Operation arming disarming through the keypad on panel which brings convenience to users 8 The system can record 10 seconds of voice info four phone numbers and two alarm center numbers can be preset as alarm
2. at once and dial automatically whether it is in arming status or not Dealing with Alarm The system will make horn hoot for 5 minutes to frighten intruder while it also dials the saved phone numbers automatically Hosts will hear the saved alarm message when they pick up the telephone Press the to enter 2 minutes of spot monitoring status press to confirm receiving alarm The main panel will stop dialing and close horn The system will arm again If one number can t be put through it will turn to next alarm number automatically and dial every number for 5 times Remote Phone Call Arming Disarming Monitoring You can use any telephone dialing main panel number it will put through automatically after 8 rings and play the word welcome to intelligent remote control system please enter your password If your password is right you can get a beep to confirm it at this timef 1 Jas arming 2 Jas disarming Jas monitoring for 3 minutes The system will quit automatically if there is no any operation within 1 minute They system will say sorry bye bye and hang on if you input wrong password for 3 times 8 9 5 Remote Phone Control Electronic Appliance Static current 11 lt 100ua Emission current 12 lt 20ma Emission frequency 315 433MHz Emission time T 1 second This kit will remote control 4 phone appliance switch When going into remote control status and pass the password key in 0 serial number and serial nu
3. confirm entering code status you can key in your code when the figure bar cursor twinkling on the foot of the screen pressing to confirm It s a 4 digit number please remember it the original password is 1234 Setting Arming Alarm Delay Time There are three delay time available 20 sec 40sec and 60 sec are standby Press the key program on the panel under the disarming status then press A and V to twinkle typeface other setup press to display typeface with horn without horn arming delay press A and Y to make arming delay twinkle pressing to confirm At last you can press A Jand Y Jto choose the arming alarm delay time you want then press to confirm the original setup is 20 sec Setting up Date and Time Press the key program on the panel under the disarming status then press A and Y to twinkle typeface other setup press then A and Y to make icon date twinkle pressing to confirm At last you can press A and Y to choose the data you want then press to confirm notice it is required to reset date and time after electrify every time in order to record alarm system info accurately Setting up Defense Zone Press the key Area set on the panel under the disarming status then press A and Y to choose the right one you want to arm from 1 8 defense zone press to confirm When the typeface type place detector display
4. inning once power supply turn on and twinkle when there is a patrol fault signal 6 Function key Browse inquiring about relative info of each defense zone History inquiring about info of arm disarm alarm time and defense zone A Y page up and page down Code for coding detector remote controller and intelligent remote control switch together with setting up users code Defense zone setup for entry into defense zone setup status Program for entry into program mode 3 Arming away to start up arming away mode arming Stay to start up arming at home mode Return Return to previous menu or quit Power supply faucet Wired defense zone faucet Voice record button Siren faucet Line out faucet Line in faucet ystem installation Main panel lug the siren into faucet on the back side telephone line into line in faucet joint elephone and the panel thro line out faucet Plug the power supply turn on the switch hen done with the installation press the key unlock to let panel in disarm status in case hat it alarms when user install door magnetic and PIR You can hear one beep in gear hen the power supply switch is turned on The panel will beep on time every 30 sec to remind of recording alarm message and telephone numbers Beep will stop once the setting is over 2 Door window contact It will aware the open close of door or window Fix magnet and transmit box separately on the door and door frame with sticker
5. m on the panel under the disarming status the press A and Y to twinkle typeface other setup press to confirm press A and Y to make system initialization twinkle pressing to confirm All the setup will be recovered to original status The code of P I R door magnet remote controller intelligent remote control switch will lose and must be re code System Usage l Arm Disarm Keyboard Arming Disarming Key in 4 digit password on keyboard under disarming status press the key out going to away disarming status press the key home going to stay disarming status Key in 4 digit password on keyboard under arming or alarm status press to disarm Current status will display on the screen at the same time Notice All the defense zones will take effect under out status the mode is suitable for nobody in Part of the defense zones take effect under home status the model is suitable for anybody in Remote Controller Arming Disarming Press the key lock on the remote controller the system will enter away disarming status about 20 60 sec delay later By use the key lock together with Urgency on the remote controllers you can arm at once Main panel will send off indicating tone to denote that phone line are not ready Press the key Unlock on the remote controllers to disarm Panic Alarm Press the middle key Urgent on the remote controller or on the panel the system will alarm
6. mber 1 4 remote control switch The intelligent remote control switch will change its status between turning on and turning off You should hang up and go into remote control Emission distance without obstruct 80m system again if you want to change its status intelligent remote control switch panel itself can operate switch by manual work System Main Tech Parameter E Main panel Power supply AC 220V DC 9V 1A Inside battery Ni cd charge battery DC 7 2V Working current 12 lt 50ma Alarm current 12 lt 300ma Wireless receiving frequency 315 433MHz Wireless receiving sensitive degree 5 mV m Anti jamming intension 1V m frequency range 20 1000MHz Outside alarm horn pitch 110db Working environment 10 C 40 C Relative humidity lt 90 Detector capacity each zone 20pcs Reliability within regular anti jamming range Misinformation rate 2times year Omission factor Otime year Emission interval lt 35seconds Detective speed 0 3 3m sec Detective distance 5 8m Detective view level 110 vertical 60 Anti puppy jamming rodent animal bulk 30x50mm Sharp white light resistance 20000Lux Working environment temperature 10 C 40 C Relative humidity lt 90 Remote controller Power supply DC 12 8 4V Inside A23 DC 12V dry battery Static current 11 0 Emission frequency 315 433MHz Emission current 12 lt 15ma Emission time TS lt 1 second Emission distance without obstruct 80m Working envi
7. n the panel to see the display alarm telephone twinkle then press to confirm entering setting up alarm telephone numbers at this time 1 group 2 group 3 group 4 group CTR1 CTR2 on st display and group twinkling Confirming by the key the figure cursor twinkling and you can input the first alarm telephone number by figure keyboard pressing to confirm Then the next telephone number the rest setting by the same way The digit numbers no more than 15 It s allowed to insert among a number to come out if it is connected on a extension telephone a second pause will appear Press the key A and Y you can revise or delete the saved numbers Alarm center number is priority than user s alarm number Setting Up Horn The alarm system could decide to use horn or not just up to your demand Press the key program on the panel under the disarm status Then press A and Y to twinkle typeface with horn without horn arming delay press A and Y to make with horn twinkle press to confirm you can find a horn icon on the right foot of the screen it indicates the horn in working order 4 Setting Up Password Arming disarming and telephone remote control function are all required to use password Setup step is as below press the key program on the panel under the pending status then press A and Y to twinkle typeface Revise Password press to
8. number 9 Defense number and alarm type will be informed by voice 10 Remote control the on amp off for 3 paths of electronic appliances by phone 11 Long distance arm disarm by phone and monitor the sound on spot 12 Can save 40 arm disarm and alarm records including time defense zone and detector location etc 13 With the patent tech of detector self inspection the panel will lighten the fault indicator light to show the right location and remind of user if it hasn t receive the signal from detector within 24 hours 14 There are 20 sec 40 sec and 60 sec alarm delay to choose users can entry disarm thru keypad when not taking with remote control 15 Alarm is priority in the system whenever the phone is picked up or not 16 The panel will send out hurry beeps every one minute and the siren will sound nonstop if phone wire is cut off due to destroy 17 Ongoing charges supply inside the system to keep working at least 24 hours when power off 18 The system has memory function to guarantee previous status after power cut off and recover Main Panel Sketch Map 1 Screen 2 figure key means pause for 1 sec when setting up alarm telephone and means confirmation when disarming is for inputting confirmation 3 arming indication light The indication light twinkle during arming delay and keep shinning after arming alarm indication light 5 power supply patrol indication light The light keep s
9. on the screen press A and Y to lock your aim The defense zone type include out home delay the system will skip to delay cursor enquiring if you want to set this zone as delay zone whichever you choose out or home Press to confirm and Return to skip Defense zone places include hall bedroom kitchen sanctum storehouse balcony passage office etc Detectors include P I R door magnet panic gas smoke etc Code for Detector Press the key code after press to confirm the detector you want to code under the defense zone setup status The detector icon will flash awaiting your fittings triggering The panel will send out one beep to denote successful code Please shut off the power of the previous detector then go to the next fitting code i e switch on the PIR letting signal lamp light one time stagger the door gap detector transmit box and letting signal lamp light one time Continuous beeps denote the detector is not suited Every defense zone could accept several detectors Attached detectors have been coded before selling door magnets have been set as the first defense zone stay defense no delay hall The P I R is regarded as the second defense zone out defense zone no delay bedroom 10 11 12 13 Remote Controller Code Press the key on the panel program on the panel under the disarm status then press A and Y to twinkle typeface other setup press to c
10. onfirm Press A and V to make remote control code twinkle pressing to confirm entering remote control status At last press Code to add your aim remote controller one by one during the icon remote control code flashing it sends out one beep to confirm Attached remote controllers have been coded before selling Intelligent Remote Control Switch Code Press the key Code two times under the disarming status main panel will enter the coding status press random key of the remote controller of intelligent remote control switch One beep denotes the successful code Attached intelligent remote controller switch have been coded before selling Browse And History Press the key Browse on the panel under the disarming status then press A J and Y to browse set condition of 1 8 defense zone including defense zone type defense zone places and detector type Press the key history Jon the panel under the disarming status then press A and Y to browse 40 arming disarming history records including event type time and defense zone information Setting up User s Code Press holding the key Code for 3 sec key in 4 digit user s code when figure bar cursor twinkling on panel screen The code will be transmitted to alarm center to identify the users If your system has not connected with the center yet it is no necessary for you to set up user code System Initialization Press the key Progra
11. or screw Pay attention to keep the space between transmit box and the magnet is no more than 2mm 3 PIR The device can detect human body motion within certain a range fix it on the wall of main passage or important area and avoiding direct light irradiation Also it should be kept away from air conditioner and stove etc Its installation height is suggested within 2 to 2 2 meters and its detection angle should be adjusted fact to detector zone directly PI R goes to work after 1 minute warm up once turning on the power supply switch notice Installation position will cause the alarm veracity 4 Joint Wired Detector The main panel has 7 wired detector faucets the terminal are anode and cathode of 12V direct current output which loads max 200ma current Connect one end of signal line 4 to anode while the other end to opposite faucet A G means 1 7 defense zones There is no delay alarm mode for wired defense zone System Setup l U Record Alarm Message Under disarm status press the key Record on the back of main panel and keep 3 seconds starting to record toward the panel after hearing one beep The leave word time should be 10 sec and the two beeps a short one and a longer one indicating the quit when it is over The alarm message must concise For example this is XXX address intruder enter the house please take action Setting Up Alarm Telephone Numbers Under the disarm status press the program key o
12. ronment 10 C 40 C Relative humidity lt 90 Whole Kit List E Door window gap detector 1 main panel Ipc Power supply DC 12 8 4V Inside A23 DC 12V dry battery 2 door magnet lpair Static current 11 lt 20ua 3 PI Rdetector Ipc Emission current 12 lt 15ma 4 remote controller 2pcs Emission time T21 second 5 regulator power supply Ipc Emission distance without obstruct 80m apart distance lt 15mm Working environment 10 C 40 C Relative humidity lt 90 E P I R detector Power supply DC 4 5 7 2V Inside 5 battery 3PCS 6 Storage user manual Ipc Storage condition temperature 10 C 40 C Relative humidity lt 75 Ventilation without corrupt object standard pile layers lt 6