         Contents
1.                                                                               PARAMETERS OF LEVEL 1  NAME RANGE   FACTORY FUNCTION  SETTING  T za   CO 30   60   C 50  C Minimal temperature of fireplace at which the pump P3 CO   is activated   Tza   CWU 20   85   C 50  C Minimal temperature of fireplace at which the pump PI CWU   turns on   Tmax CWU 30   100 65  C Maximal temperature of CWU accumulator  The exceeding  we turns off the supply pump  Tmin CWU 30   100 50  C Minimal temperature of CWU accumulator  The exceeding  g  turns on the supply pump  DeltaCWU 1   10  C 22  C Minimal difference between fireplace and CWU accumulator  temperature needed for the pump operation P1  CWU   PARAMETERS OF LEVEL 2  NAME RANGE   Factory FUNCTION  STRF1 from 0 00   23 45 6 00 Start of 1st time zone  STRF1 till 0 00   23 45 8 00 End of Ist time zone  STRF2 from 0 00   23 45 14 00 Start of 2nd time zone  STRF2 till 0 00   23 45 17 30 End of 2nd time zone  STRF3 from 0 00   23 45 20 00 Start of 3rd time zone  STRF3 till 0 00   23 45 22 30 End of 3rd time zone                            
2.       ITS ENVIRONS OUGHT TO BE CLEAN   THE PRODUCER DOESN T TAKE ANY RESPONSIBILITY FOR  DAMAGES CAUSED BY WRONG USAGE OF THE REGULATOR            Connection diagram of the elements of the regulator is presented on fig  3    THE REGULATOR SHOULD NOT BE EXPOSED TO WATER AFFECTING     3 1 Time zones    The regulator is equipped with the clock  which enables the automatic change of the regulator  operation at different times of day  24 hrs are divided into 3 time zones   1   2   3  and the single time  when no zone is active that is ZONE 0 or BAZA  BASE   Each zone has a start time  OD  FROM  and an end time  DO  TILL    For the regulator factory settings are as it follows     ZONE 1 FROM 6 00 TILL 8 00  ZONE 2 FROM 14 00 TILL 17 30  ZONE 3 FROM 20 00 TILL 22 30    3 2 Screens    Alarm screens is not seen till the following emergency situation takes place   1  Damage of sensor T1  upper one of CWU      T1    shows up  The alarm doesn   t work if the sensor  is not installed   2  Damage of sensor T2  lower one of CWU      T2    shows up   3  Damage of sensor T3  of fireplace      T3    shows up   4  The exceeding of the acceptable temperature of fireplace         TEMP KOM       defined by  the    T ALARMU    parameter    ALARM     T1    Emergency situation is accompanied by a broken sound alarm that can be turned off by pressing the  USTAW button   In emergency of temperature exceeding the pump CO turns on to cool off fireplace           Screen of fireplace water jacket temperatu
3.    Admission date   Realization date Signature REMARKS                                           TUINE  RT08K 2008 TITANIUM ANG  CO    Zak  ad elektroniczny TATAREK Jerzy Tatarek    USER MANUAL    RT 08K  REGULATOR  OF  HEATING SYSTEM WITH FIREPLACE          The regulator controls heating system based on a water jacket fireplace which is a heat source  The  heat receivers are  applicable warm water accumulator  CWU  and central heating system  CO                                          WNASSX  Zak  ad elektroniczny TATAREK Jerzy Tatarek    50 559 Wroclaw  75 Swieradowska st   ph   071  367 21 67  373 14 88  fax 373 14 58   Bank account  BZ WBK S A  WROC  AW 6910901522 0000 0000 5201 9335  www tatarek com pl   e mail  tatarek tatarek com pl          1 Basic technical parameters     Power 230V 50Hz  Power consumption without load 5W  Max connection power 750W    Operation conditions    Housing protection class   Fuse   Number of outputs to control pumps  Number of nonvoltage outputs  Number of water temperature sensors    0 50  C  humidity 10 90    No condensation    IP41   6 3A 250V   3   250W 230V 50Hz   1   3   KTY81  0    100  C      Temp  measurement precision 2  C  Temp  measurement resolution 0 5  C  Number of time zones 4    2  Principle of operation  The regulator RT O8K controls the pump that supplies the applicable warmwater accumulator   P1   The pump P1 operates if both a fireplace temperature exceeds the ZA   CWU value and is higher  than the temperature of the C
4.  The regulator is equipped with the relay CONTROL whose contacts can be used e g  to switch  off another heat source when a fireplace works  The    PrzekSTR    parameter defines the function of  the relay more precisely    3 Service of the regulator    There are elements on the control panel  fig  2     The state is presented on the text display  1   The screens inform about the operation of devices   temperature of sensors  they make it possible to change the parameters etc   The change of screen is  done by pressing the WYBIERZ button  3   If this is the screen that is able to change a parameter   press the USTAW button  which causes blinking of the parameter field to be changed  By pressing           2  or          4  one can alter its value    If there are more parameter fields on the screen  e g  setting the clock  then one will go among them  by pressing the WY BIERZ button  3         Fig 2 Control panel view    Text display   Increase button   Choice button of parameter  Decrease button   Confirm button    AES a    By clicking the USTAW button  5  one confirms the changes   the parameter field stops blinking   The changed parameter not confirmed for 10 secs is not accepted by the regulator and it recalls a  previous value of the parameter     Temperature  sensors    o Ti          T2  e  ta    T3        CONTROL    Pump P1 ane  p P2  230V 50Hz 230V 50Hz  MAINS    230V 50Hz Soon  Pump P3  230V 50Hz    Fig 3 Electrical scheme    Tl    T2    T3    P1    P2    P3    Upper te
5. To the conformity evaluation the following harmonized standards were used     PN EN 60730 2 1  2002   Automatic electric regulators for house usage and the like  Part 2 1   Specific requirements regarding electric regulators for electric house  devices   Automatic electric regulators for house usage and the like    Part 1  General requirements     PN EN 60730 1  2002      PN EN 55022  2000   Electromagnetic compatibility  EMC   IT devices  Characteristics of radioelectric noises  Acceptable levels and measurement methods    Complementary information   Laboratory IASE 51 618 Wroclaw  1 Wystawowa st     39 DL 1 07 of 22 06 2007  41 DL 1 07 of 03 07 2007    Test report No     Electronic Engineering Plant TATAREK  has initiated management system and complies with the following standard    ISO9001  2000 CERTIFICATE No  133 2004 of 01 2004  Polish Foreign Trade Chamber    The last two digits of the year in which the CE marking was affixed  07    Place of issue  Manufacturer representative     Wroclaw Miroslaw Zasepa  Las name  Date of issue  Position   08 2007 Konstruktor    WARRANTY    1 Warranty is valid  24  months from the date of sale    2 Producer does not take responsibility for any mechanical damages made by user   3 MAKING REPAIRS OR MODYFYING THE DEVICE BY USER IS   FORBIDDEN AND CAUSES WARRANTY CANCELATION   4 Warranty card is valid only with date of sale  seller s signature and stamp  5 Warranty and after warranty repairs should be done only by producer  damaged  regula
6. WU accumulator  T2  by the DeltaCWU value  see  PARAMETERS OF LEVEL 1    The second function is the control ofthe circulating pump ofthe central heating system P3    The pump works if a fireplace temperature exceeds the ZA   CO value  It   s possible to turn on the  CWU priority function  see the description of the operation modes of the central heating pump CO   The regulator is equipped with the clock to control the CWU priority over the selected times of  the day         KOIL         Fig la Basic configuration of regulator operation       3                               Fig 1b Configuratio of regulator operation with heat exchanger for the CO central heating system   pump of the heat exchanger and CO connected to the output P3     a     CWU                   Fig lc Configuration of regulator operation with heat exchanger for the CO and CWU systems       WANA    PRODUCENT ZASILACZY SIECIOWYCH    ISO 9001  2000    CE CONFORMITY DECLARATION  Ref  No  58 RT 01 2007 1 B    We  ZAKLAD ELEKTRONICZNY TATAREK Jerzy Tatarek  75 Swieradowska St    50 559 Wroclaw    declare under our sole responsibility that  the product  Regulator of heating system with solar collector    model  RT 08  RT 08K  RT 08P    is in conformity with the basic requirements included in Directive EMC 2004 108 WE of 15 12 2004  the  electromagnetic compatibility law of 13 04 07  and Directive LVD 2006 95 WE of 21 08 07  Laws Journal  of 2007 No  155 pos  1098  regarding the requirements for electric devices     
7. e 2 ways of supplying the accumulator CWU     e Keeping the accumulator CWU at maximal readiness  Parameter       SterCWU    1    The supply starts if the lower temperature sensor of CWU  T2  shows temperature below 65  C        maxCWU    parameter      e Optimal supply  Parameter    SterCWU    2    from partial discharge to max supply  The  supply turns on if the upper temperature sensor of CWU  T1  shows temperature lower than 50  C      TminCWU    parameter  and turns off if the lower temperature sensor of CWU  T2  shows  temperature higher than 65  C   TmaxCWU    parameter    The regulator realizes the after season rundown of the pump by switching it on for 1 min if it doesn   t  operate for a week     2 3 CWU priority and summer mode   In the regulator one can set    TrybCWU    parameter achieving different strategies of operation   Possible modes are    WY     The pump CWU turned off   LATO  Turning off the heating system in summer time  the pump CO doesn   t operate   Fireplace  only works in the preparation function CWU    ZA     Standard operation  parallel operation of Pumps  without favouring the CWU circuit    PRIO Faster reaching the readiness of CWU accumulator by limiting heat obtain by heating  system  The pump CO works cyclically  Turning off the pump CWU after supplying the accumulator  causes the comeback of normal operation of the pump CO   ZEGAR beyond time zones the pump operates like in the ZAL mode and in time zone like PRIO    2 4 Output  CONTROL     
8. f CWU   T3 Temperature sensor of fireplace water jacket   P1 Pump supplying CWU from fireplace   P2 Pump of the primary side of heat exchanger  it operates if P1 and P3 are activated     P3 Circulating pump CO  2 1 Pump CO operation    If fireplace temperature exceeds a set value of 45  C     T zat CO    parameter  the pump CO turns on   The switch off of the pump below the value causes a faster heating of the water jacket above the dew  point and by that a longer life time of the fireplace    During supplying the applicable warm water accumulator CWU  the pump can operate cyclically if  the CWU priority is set  Limitation of the heat amount flowing into the system CO     The cyclical operation is based on turning on the pump for 45 secs and then turning off for 4min     t stopCO    parameter     The regulator protects the system from freezing  automatically turning on the circulating pump if the  measured temperature is below 4  C    The regulator realizes the after season rundown of the pump by switching it on for 1 min if it doesn   t  operate for a week           2 2 Pump CWU operation    The regulator controls as well the pump supplying the applicable warm water accumulator CWU   The pump CWU is to turn on if water temperature in fireplace is higher than the threshold of 45  C      T zatCWU    parameter  and higher than in the accumulator CWU by 5  C     DeltaCWU     parameter   If CWU temperature exceeds 65  C     T maxCWU    parameter  the pump CWU turns off   There ar
9. mperature sensor of solar collector  option    Lower temperature sensor of CWU accumulator   Temperature sensor of fireplace water jacket   Pump supplying CWU accumulator from a fireplace   Pump of the primary side of heat exchanger  it operates if P1 or P3 is activated     Circulating pump CO             PARAMETERS OF LEVEL 3                   NAME RANGE FACTORY FUNCTION  SETTING  t StopCO 1   30mins 4mins Pause time of CO pump in cyclical mode  After the time the pump  turns on for 45 secs   Ster CWU Leaz 1    Kind of supply for the CWU accumulator            Temperature sensor T2  down  controls the supply of CWU       2 Temperature sensors T1  up  and T2  down  control  the supply of CWU accumulator  ireplace temperature at which alarm turns on        T ALARMU 75   89  C 85  C    E                      Switch on of the relay CONTROL if   fireplace temperature is higher than     T za   CO      fireplace temperature is higher than  T zaf CWU  CWU temperature measured by T2 sensor is higher  than    TminCWU       PrzekSTR 1   6 1               N       w       CWU temperature measured by T1 sensor is higher than       CWU temperature measured by T2 sensor is higher than       fireplace temperature is higher than    an                               4 Installing the regulator     THE REGULATOR IS SUPPLIED BY 230V 50HZ    ANY MOVES REGARDING INSTALLATION SHOULD BE MADE AT   THE DISCONNECTED MAINS    THE REGULATOR HAS TO BE CONNECTED TO THE MAINS WITH THE  ZERO PIN     o       o 
10. ossible modes are    WY     The pump CWU turned off   LATO  Turning off the heating system in summer time  the pump CO doesn   t operate   Fireplace  only works in the preparation function CWU    ZAL   Standard operation  parallel operation of pumps  without favouring the CWU circuit  PRIO Faster reaching the readiness of CWU accumulator by limiting heat obtain by heating  system  The pump CO works cyclically  Turning off the pump CWU after supplying the accumulator  causes the comeback of normal operation of the pump CO   ZEGAR beyond time zones the pump operates like in the ZA   mode and in the time zone like PRIO       6       Screen of clock    ZEGAR  1  I7 15    The screen shows the actual time and the number of active time zone   Time correction is possible after pressing the USTAW button  5  and the minutes field begins  blinking  The blinking value can be altered with the buttons         or          Pressing the WYBIERZ    button  3  one comes to the hours field that can be set with the buttons         or           Pressing the USTAW button confirms the changes  the clock field will stop blinking      Screen of setting the parameters       PoziomUSs  0  Normally the parameters setting level equals to    0    namely the parameters aren   t available     After changing the level to    1        2    or    3    successive screens show the values of parameters   The last screen contains            after which it comes back to the above mentioned screens                    
11. re measurement shows the actual temperature of  fireplace                   It   s a stable state that is in order to change it one needs to press the WY BIERZ button       Screen of CWU temperature shows the actual temperature in the upper and lower part of the CWU  accumulator           o    CWU 80      lt        Upper temperature sensor T1  if available     68      lt        Lower temperature sensor T2    It   s a stable state that is in order to change it one needs to press the WYBIERZ button       Screen of whole system operation   On the screen are the symbols of devices   KOM  fireplace   CO   central heating system   CWU   applicable warm water accumulator     ifthe relay CONTROL is switched on    The symbols  every few seconds or after pressing USTAW button  are replaced with numbers  presenting the temperatures of those devices    The blinking arrows mean the actual heat flow as an effect of pumps operation    KOM  gt CWU the pump P  supplying the CWU accumulator is turned on    KOM  gt CO the pump P3 is turned on     CO    lt     CONTROL relay is turned on   KOM  gt CWU   80    lt     upper sensor of CWU  73   68          lower sensor of CWU  t fireplace sensor    Ifthe summer mode is active  only CWU   LATO replaces CO   It   s a stable screen that is in order to change it one needs to press the WYBIERZ button    Screen of CWU operation mode       TrybCwuU  LATO    In the regulator one can set    TrybCWU    parameter achieving different strategies of operation   P
12. tors should be sent to producer in order to make all repairs needed   6 Warranty protection involves the EU   7 Warranty does not exclude  not restrict and not suspend buyer   s rights coming from  the incompatibility of the article with the agreement  Laws Journal No  141 Pos  1176     WARNING     ANY MODIFICATION OF THE REGULATOR MADE BY USER CAN BE  THE CAUSE OF SAFETY CONDITIONS DETERIORATION AND CAN  EXPOSE THE USER TO ELECTRIC SHOCK OR DAMAGE DEVICES  SUPPLIED        WARNING   1  Producer does not take the responsibility for damage  caused by atmospheric discharge  2  and overvoltage in the mains  3  Burnt fuses are not subject to warranty replacement       Date of sale Seller s signature and stamp    ARGO FILM  Recycling Plant No  6  180 Krakowska st   52 015 Wroclaw    Register No   GIOS  E 0002240WZ    Worn out electronic    the utilization collection place  where will 0 515 122 142    be accepted for free    and electric devices must be transfered to Ph   071 794 43 01  Y       INIA        Zak  ad elektroniczny TATAREK Jerzy Tatarek    50 559 Wroclaw  75 Swieradowska st  ph   071  367 21 67  373 14 88  fax 373 14 58  tax index number 899 020 21 48   Bank account   BZ WBK S A  O WROCLAW 6910901522 0000 0000 5201 9335  www tatarek com pl   E mail  tatarek tatarek com pl       10          CWU Applicable Warm Water Accumulator  boiler   KOM Water jacket fireplace  CO Central heating system    T1 Upper temperature sensor of solar collector   T2 Lower temperature sensor o
    