user manual rt-08k regulator of heating system with fireplace

image

Contents

1. PARAMETERS OF LEVEL 1 NAME RANGE FACTORY FUNCTION SETTING T za CO 30 60 C 50 C Minimal temperature of fireplace at which the pump P3 CO is activated Tza CWU 20 85 C 50 C Minimal temperature of fireplace at which the pump PI CWU turns on Tmax CWU 30 100 65 C Maximal temperature of CWU accumulator The exceeding we turns off the supply pump Tmin CWU 30 100 50 C Minimal temperature of CWU accumulator The exceeding g turns on the supply pump DeltaCWU 1 10 C 22 C Minimal difference between fireplace and CWU accumulator temperature needed for the pump operation P1 CWU PARAMETERS OF LEVEL 2 NAME RANGE Factory FUNCTION STRF1 from 0 00 23 45 6 00 Start of 1st time zone STRF1 till 0 00 23 45 8 00 End of Ist time zone STRF2 from 0 00 23 45 14 00 Start of 2nd time zone STRF2 till 0 00 23 45 17 30 End of 2nd time zone STRF3 from 0 00 23 45 20 00 Start of 3rd time zone STRF3 till 0 00 23 45 22 30 End of 3rd time zone
2. ITS ENVIRONS OUGHT TO BE CLEAN THE PRODUCER DOESN T TAKE ANY RESPONSIBILITY FOR DAMAGES CAUSED BY WRONG USAGE OF THE REGULATOR Connection diagram of the elements of the regulator is presented on fig 3 THE REGULATOR SHOULD NOT BE EXPOSED TO WATER AFFECTING 3 1 Time zones The regulator is equipped with the clock which enables the automatic change of the regulator operation at different times of day 24 hrs are divided into 3 time zones 1 2 3 and the single time when no zone is active that is ZONE 0 or BAZA BASE Each zone has a start time OD FROM and an end time DO TILL For the regulator factory settings are as it follows ZONE 1 FROM 6 00 TILL 8 00 ZONE 2 FROM 14 00 TILL 17 30 ZONE 3 FROM 20 00 TILL 22 30 3 2 Screens Alarm screens is not seen till the following emergency situation takes place 1 Damage of sensor T1 upper one of CWU T1 shows up The alarm doesn t work if the sensor is not installed 2 Damage of sensor T2 lower one of CWU T2 shows up 3 Damage of sensor T3 of fireplace T3 shows up 4 The exceeding of the acceptable temperature of fireplace TEMP KOM defined by the T ALARMU parameter ALARM T1 Emergency situation is accompanied by a broken sound alarm that can be turned off by pressing the USTAW button In emergency of temperature exceeding the pump CO turns on to cool off fireplace Screen of fireplace water jacket temperatu
3. Admission date Realization date Signature REMARKS TUINE RT08K 2008 TITANIUM ANG CO Zak ad elektroniczny TATAREK Jerzy Tatarek USER MANUAL RT 08K REGULATOR OF HEATING SYSTEM WITH FIREPLACE The regulator controls heating system based on a water jacket fireplace which is a heat source The heat receivers are applicable warm water accumulator CWU and central heating system CO WNASSX Zak ad elektroniczny TATAREK Jerzy Tatarek 50 559 Wroclaw 75 Swieradowska st ph 071 367 21 67 373 14 88 fax 373 14 58 Bank account BZ WBK S A WROC AW 6910901522 0000 0000 5201 9335 www tatarek com pl e mail tatarek tatarek com pl 1 Basic technical parameters Power 230V 50Hz Power consumption without load 5W Max connection power 750W Operation conditions Housing protection class Fuse Number of outputs to control pumps Number of nonvoltage outputs Number of water temperature sensors 0 50 C humidity 10 90 No condensation IP41 6 3A 250V 3 250W 230V 50Hz 1 3 KTY81 0 100 C Temp measurement precision 2 C Temp measurement resolution 0 5 C Number of time zones 4 2 Principle of operation The regulator RT O8K controls the pump that supplies the applicable warmwater accumulator P1 The pump P1 operates if both a fireplace temperature exceeds the ZA CWU value and is higher than the temperature of the C
4. The regulator is equipped with the relay CONTROL whose contacts can be used e g to switch off another heat source when a fireplace works The PrzekSTR parameter defines the function of the relay more precisely 3 Service of the regulator There are elements on the control panel fig 2 The state is presented on the text display 1 The screens inform about the operation of devices temperature of sensors they make it possible to change the parameters etc The change of screen is done by pressing the WYBIERZ button 3 If this is the screen that is able to change a parameter press the USTAW button which causes blinking of the parameter field to be changed By pressing 2 or 4 one can alter its value If there are more parameter fields on the screen e g setting the clock then one will go among them by pressing the WY BIERZ button 3 Fig 2 Control panel view Text display Increase button Choice button of parameter Decrease button Confirm button AES a By clicking the USTAW button 5 one confirms the changes the parameter field stops blinking The changed parameter not confirmed for 10 secs is not accepted by the regulator and it recalls a previous value of the parameter Temperature sensors o Ti T2 e ta T3 CONTROL Pump P1 ane p P2 230V 50Hz 230V 50Hz MAINS 230V 50Hz Soon Pump P3 230V 50Hz Fig 3 Electrical scheme Tl T2 T3 P1 P2 P3 Upper te
5. To the conformity evaluation the following harmonized standards were used PN EN 60730 2 1 2002 Automatic electric regulators for house usage and the like Part 2 1 Specific requirements regarding electric regulators for electric house devices Automatic electric regulators for house usage and the like Part 1 General requirements PN EN 60730 1 2002 PN EN 55022 2000 Electromagnetic compatibility EMC IT devices Characteristics of radioelectric noises Acceptable levels and measurement methods Complementary information Laboratory IASE 51 618 Wroclaw 1 Wystawowa st 39 DL 1 07 of 22 06 2007 41 DL 1 07 of 03 07 2007 Test report No Electronic Engineering Plant TATAREK has initiated management system and complies with the following standard ISO9001 2000 CERTIFICATE No 133 2004 of 01 2004 Polish Foreign Trade Chamber The last two digits of the year in which the CE marking was affixed 07 Place of issue Manufacturer representative Wroclaw Miroslaw Zasepa Las name Date of issue Position 08 2007 Konstruktor WARRANTY 1 Warranty is valid 24 months from the date of sale 2 Producer does not take responsibility for any mechanical damages made by user 3 MAKING REPAIRS OR MODYFYING THE DEVICE BY USER IS FORBIDDEN AND CAUSES WARRANTY CANCELATION 4 Warranty card is valid only with date of sale seller s signature and stamp 5 Warranty and after warranty repairs should be done only by producer damaged regula
6. WU accumulator T2 by the DeltaCWU value see PARAMETERS OF LEVEL 1 The second function is the control ofthe circulating pump ofthe central heating system P3 The pump works if a fireplace temperature exceeds the ZA CO value It s possible to turn on the CWU priority function see the description of the operation modes of the central heating pump CO The regulator is equipped with the clock to control the CWU priority over the selected times of the day KOIL Fig la Basic configuration of regulator operation 3 Fig 1b Configuratio of regulator operation with heat exchanger for the CO central heating system pump of the heat exchanger and CO connected to the output P3 a CWU Fig lc Configuration of regulator operation with heat exchanger for the CO and CWU systems WANA PRODUCENT ZASILACZY SIECIOWYCH ISO 9001 2000 CE CONFORMITY DECLARATION Ref No 58 RT 01 2007 1 B We ZAKLAD ELEKTRONICZNY TATAREK Jerzy Tatarek 75 Swieradowska St 50 559 Wroclaw declare under our sole responsibility that the product Regulator of heating system with solar collector model RT 08 RT 08K RT 08P is in conformity with the basic requirements included in Directive EMC 2004 108 WE of 15 12 2004 the electromagnetic compatibility law of 13 04 07 and Directive LVD 2006 95 WE of 21 08 07 Laws Journal of 2007 No 155 pos 1098 regarding the requirements for electric devices
7. e 2 ways of supplying the accumulator CWU e Keeping the accumulator CWU at maximal readiness Parameter SterCWU 1 The supply starts if the lower temperature sensor of CWU T2 shows temperature below 65 C maxCWU parameter e Optimal supply Parameter SterCWU 2 from partial discharge to max supply The supply turns on if the upper temperature sensor of CWU T1 shows temperature lower than 50 C TminCWU parameter and turns off if the lower temperature sensor of CWU T2 shows temperature higher than 65 C TmaxCWU parameter The regulator realizes the after season rundown of the pump by switching it on for 1 min if it doesn t operate for a week 2 3 CWU priority and summer mode In the regulator one can set TrybCWU parameter achieving different strategies of operation Possible modes are WY The pump CWU turned off LATO Turning off the heating system in summer time the pump CO doesn t operate Fireplace only works in the preparation function CWU ZA Standard operation parallel operation of Pumps without favouring the CWU circuit PRIO Faster reaching the readiness of CWU accumulator by limiting heat obtain by heating system The pump CO works cyclically Turning off the pump CWU after supplying the accumulator causes the comeback of normal operation of the pump CO ZEGAR beyond time zones the pump operates like in the ZAL mode and in time zone like PRIO 2 4 Output CONTROL
8. f CWU T3 Temperature sensor of fireplace water jacket P1 Pump supplying CWU from fireplace P2 Pump of the primary side of heat exchanger it operates if P1 and P3 are activated P3 Circulating pump CO 2 1 Pump CO operation If fireplace temperature exceeds a set value of 45 C T zat CO parameter the pump CO turns on The switch off of the pump below the value causes a faster heating of the water jacket above the dew point and by that a longer life time of the fireplace During supplying the applicable warm water accumulator CWU the pump can operate cyclically if the CWU priority is set Limitation of the heat amount flowing into the system CO The cyclical operation is based on turning on the pump for 45 secs and then turning off for 4min t stopCO parameter The regulator protects the system from freezing automatically turning on the circulating pump if the measured temperature is below 4 C The regulator realizes the after season rundown of the pump by switching it on for 1 min if it doesn t operate for a week 2 2 Pump CWU operation The regulator controls as well the pump supplying the applicable warm water accumulator CWU The pump CWU is to turn on if water temperature in fireplace is higher than the threshold of 45 C T zatCWU parameter and higher than in the accumulator CWU by 5 C DeltaCWU parameter If CWU temperature exceeds 65 C T maxCWU parameter the pump CWU turns off There ar
9. mperature sensor of solar collector option Lower temperature sensor of CWU accumulator Temperature sensor of fireplace water jacket Pump supplying CWU accumulator from a fireplace Pump of the primary side of heat exchanger it operates if P1 or P3 is activated Circulating pump CO PARAMETERS OF LEVEL 3 NAME RANGE FACTORY FUNCTION SETTING t StopCO 1 30mins 4mins Pause time of CO pump in cyclical mode After the time the pump turns on for 45 secs Ster CWU Leaz 1 Kind of supply for the CWU accumulator Temperature sensor T2 down controls the supply of CWU 2 Temperature sensors T1 up and T2 down control the supply of CWU accumulator ireplace temperature at which alarm turns on T ALARMU 75 89 C 85 C E Switch on of the relay CONTROL if fireplace temperature is higher than T za CO fireplace temperature is higher than T zaf CWU CWU temperature measured by T2 sensor is higher than TminCWU PrzekSTR 1 6 1 N w CWU temperature measured by T1 sensor is higher than CWU temperature measured by T2 sensor is higher than fireplace temperature is higher than an 4 Installing the regulator THE REGULATOR IS SUPPLIED BY 230V 50HZ ANY MOVES REGARDING INSTALLATION SHOULD BE MADE AT THE DISCONNECTED MAINS THE REGULATOR HAS TO BE CONNECTED TO THE MAINS WITH THE ZERO PIN o o
10. ossible modes are WY The pump CWU turned off LATO Turning off the heating system in summer time the pump CO doesn t operate Fireplace only works in the preparation function CWU ZAL Standard operation parallel operation of pumps without favouring the CWU circuit PRIO Faster reaching the readiness of CWU accumulator by limiting heat obtain by heating system The pump CO works cyclically Turning off the pump CWU after supplying the accumulator causes the comeback of normal operation of the pump CO ZEGAR beyond time zones the pump operates like in the ZA mode and in the time zone like PRIO 6 Screen of clock ZEGAR 1 I7 15 The screen shows the actual time and the number of active time zone Time correction is possible after pressing the USTAW button 5 and the minutes field begins blinking The blinking value can be altered with the buttons or Pressing the WYBIERZ button 3 one comes to the hours field that can be set with the buttons or Pressing the USTAW button confirms the changes the clock field will stop blinking Screen of setting the parameters PoziomUSs 0 Normally the parameters setting level equals to 0 namely the parameters aren t available After changing the level to 1 2 or 3 successive screens show the values of parameters The last screen contains after which it comes back to the above mentioned screens
11. re measurement shows the actual temperature of fireplace It s a stable state that is in order to change it one needs to press the WY BIERZ button Screen of CWU temperature shows the actual temperature in the upper and lower part of the CWU accumulator o CWU 80 lt Upper temperature sensor T1 if available 68 lt Lower temperature sensor T2 It s a stable state that is in order to change it one needs to press the WYBIERZ button Screen of whole system operation On the screen are the symbols of devices KOM fireplace CO central heating system CWU applicable warm water accumulator ifthe relay CONTROL is switched on The symbols every few seconds or after pressing USTAW button are replaced with numbers presenting the temperatures of those devices The blinking arrows mean the actual heat flow as an effect of pumps operation KOM gt CWU the pump P supplying the CWU accumulator is turned on KOM gt CO the pump P3 is turned on CO lt CONTROL relay is turned on KOM gt CWU 80 lt upper sensor of CWU 73 68 lower sensor of CWU t fireplace sensor Ifthe summer mode is active only CWU LATO replaces CO It s a stable screen that is in order to change it one needs to press the WYBIERZ button Screen of CWU operation mode TrybCwuU LATO In the regulator one can set TrybCWU parameter achieving different strategies of operation P
12. tors should be sent to producer in order to make all repairs needed 6 Warranty protection involves the EU 7 Warranty does not exclude not restrict and not suspend buyer s rights coming from the incompatibility of the article with the agreement Laws Journal No 141 Pos 1176 WARNING ANY MODIFICATION OF THE REGULATOR MADE BY USER CAN BE THE CAUSE OF SAFETY CONDITIONS DETERIORATION AND CAN EXPOSE THE USER TO ELECTRIC SHOCK OR DAMAGE DEVICES SUPPLIED WARNING 1 Producer does not take the responsibility for damage caused by atmospheric discharge 2 and overvoltage in the mains 3 Burnt fuses are not subject to warranty replacement Date of sale Seller s signature and stamp ARGO FILM Recycling Plant No 6 180 Krakowska st 52 015 Wroclaw Register No GIOS E 0002240WZ Worn out electronic the utilization collection place where will 0 515 122 142 be accepted for free and electric devices must be transfered to Ph 071 794 43 01 Y INIA Zak ad elektroniczny TATAREK Jerzy Tatarek 50 559 Wroclaw 75 Swieradowska st ph 071 367 21 67 373 14 88 fax 373 14 58 tax index number 899 020 21 48 Bank account BZ WBK S A O WROCLAW 6910901522 0000 0000 5201 9335 www tatarek com pl E mail tatarek tatarek com pl 10 CWU Applicable Warm Water Accumulator boiler KOM Water jacket fireplace CO Central heating system T1 Upper temperature sensor of solar collector T2 Lower temperature sensor o