1. 2 Clean with water Remove dust with a vacuum cleaner wipe the unit with warm water then dry with a clean soft cloth 3 Replace the Intake Grille CD Pull the knobs all the way Mounting shaft Intake 22271117 Grille Bearing Ei Knob Hold the grille horizontal and set the left and right mounting shafts into the bearings at the top of the panel Intake Grille 3 Press the place where the arrow on the diagram indicates and close the Intake Grille Cleaning the Air Filter 1 Open the Intake Grille and remove the air filter Lift up the air filter s handle disconnect the two lower tabs and pull out Air filter handle Hooks two places 2 Remove dust with a vacuum cleaner or by washing After washing allow to dry thoroughly in a shaded place 3 Replace the Air Filter and close the Intake Grille CD Align the sides of the air filter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel Hooks two places 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild detergent and warm water If you wash the filter be sure to allow it to dry thoroughly in
2. NI 40 SET SLEEP v C4 SWING Example When set to AUTO En 6 To Stop Operation Press the START STOP button Fig 6 02 The OPERATION Indicator Lamp red Fig 3 will go out About AUTO CHANGEOVER Operation AUTO When AUTO CHANGEOVER operation first selected the fan will operate at very low speed for about one minute during which time the unit detects the room conditions and selects the proper operating mode If the differance between thermostat setting and actual room temperature is more than 2 C Cooling or dry operation If the difference between thermostat setting and actual room temperature is within 2 C Monitor operation When the air conditioner has adjusted your room s temperature to near the thermostat setting it will begin monitor operation In the monitor operation mode the fan will operate at low speed If the room temperature subse quently changes the air conditioner will once again select the appropriate operation Cooling to adjust the temperature to the value set in the ther mostat The monitor operation range is 2 C relative to the thermostat set ting If the mode automatically selected by the unit is not what you wish select one of the mode operation COOL DRY FAN About Mode Operation Cooling 6 Use to cool your room Dry Fan En 7 Use for gently cooling while dehumidifying your room You
3. Intake Port 0 Outlet Port Pipe Unit Drain port bottom 0 SLEEP button 6 MODE button 6 SET TEMP button 4 9 03 Signal Transmitter TIMER MODE button TIMER SET 1 1 button FAN button START STOP button 08 SET button Vertical SET button Horizontal 6 SWING button RESET button TEST RUN button This button is used when installing the condi tioner and should not be used under normal conditions as it will cause the air conditioner s thermostat function to operate incorrectly Ifthis button is pressed during normal opera tion the unit will switch to test operation mode and the Indoor Unit s OPERATION Indicator Lamp and TIMER Indicator Lamp will begin to flash simultaneously To stop the test operation mode press the START STOP button to stop the air condi tioner 63 CLOCK ADJUST button 4 Remote Controller Display Fig 7 69 Transmit Indicator Clock Display Operating Mode Display 68 Timer Mode Display Fan Speed Display Temperature SET Display SLEEP Display SWING Display En 4 PREPARATION Load Batteries Size AAA RO3 LRO3 x 2 CAUTION Take care to prevent infants from acciden tally swallowing batteries 1 Press and slide the battery compartment lid on the not using the Remote Controller for reverse side to open it an extended period remove the batteries to
4. a shady place before reinstalling dirt is allowed to accumulate on the air filter air flow will be reduced lowering operating efficiency and increasing noise During periods of normal use the Air Filters should be cleaned every two weeks En 12 CLEANING AND CARE Air Cleaning Filter Installation 1 Open the Intake Grille and remove the Air filters Air Filter Right amp Left 2 Install the Air cleaning filter set set of 2 Set the air cleaning filter into the air cleaning filter frame Air cleaning filter set Air cleaning filter frame Air cleaning filter Engage the latch at both ends of the filter with the two hooks at the rear of the air cleaning filter frame Hook 2 places at the rear Latch 2 places Take care that the air cleaning filter does not project beyond the frame 3 Engage the four fixing locations at the top and bottom of the air cleaning filter frame with the hooks of the air filter Rear of the filter Fixing location hook 6 places 3 Install the two Air filters and close the Intake Grille Air Filter Right amp Left When air cleaning filters are used the effect will increased by setting the fan speed to High En 13 Replacing dirty Air cleaning filters Replace filters with the following components purchase
5. cannot heat the room during Dry mode During Dry mode the unit will operate at low speed in order to adjust room humidity the indoor unit s fan may stop from time to time Also the fan may operate at very low speed when adjusting room humidity The fan speed cannot be changed manually when Dry mode has been selected Use to circulate the air throughout your room During Cooling Dry mode Set the thermostat to a temperature set ting that is lower than the current room temperature The Cooling and Dry modes will not operate if the thermostat is set higher than the actual room temperature in Cooling mode the fan alone will operate During Fan mode You can not use the unit to heat and cool your room TIMER OPERATION Before using the timer function be sure that the Remote Controller is set to the correct current time P 5 To Use the ON timer OFF timer 1 2 Press the START STOP button Fig 6 62 if the unit is already operating proceed to step 2 The indoor unit s OPERATION Indicator Lamp red Fig 3 will light Press the TIMER MODE button Fig 6 02 to select the OFF timer or ON timer operation Each time the button is pressed the timer function changes in the following order m gt CANCEL OFF ON PROGRAM OFF ON OFF lt ON The indoor unit s green TIMER Indicator Lamp Fig 3 will light Use the TIMER SET button
6. 3 for more than 20 minutes During Cooling Dry mode Horizontal flow they will be automatically returned to the range During AUTO mode operation for the first minute after beginning operation airflow will When used in a room with infants be horizontal 7 the air direction cannot be adjusted during this period children elderly or sick persons the air Direction direction and room temperature should Only the direction of the Air Flow Direction Louver changes the direction of the Power be considered carefully when making Diffuser does not change settings Horizontal Air Direction Adjustment Press the SET button Horizontal Fig 6 09 Each time the button is pressed the air direction range will change as follows a to 2 7 4 2 Ay 2 The remote controller s display does not change En 10 SWING OPERATION Begin air conditioner operation before performing this procedure To select SWING Operation Press the SWING button Fig 6 60 The SWING Display Fig 7 will light Each time the SWING button is pressed the swing operation will change in the following order gt Up down swing operation lt gt Left right swing operation L Swing operation stops 5 lt gt Up down left right swing operation To stop SWING Operation Press the SWING button and select STOP Airflow direction will retur
7. Slide in the direction of the arrow while pressing the M mark n possible leakage damage te We Batteries are not included with this product If leaking battery fluid comes in contact with your skin eyes or mouth immediately wash with copious amounts of water and Insert batteries consult your physician D O 2 Dead batteries should be removed im Be sure to align the battery polarities correctly mediately and disposed of properly either in a battery collection receptacle or to the 3 Close the battery compartment lid appropriate authority Do not attempt to recharge dry batteries Never mix new and used batteries or bat teries of different types Batteries should last about one year under normal use If the Remote Controller s 1 Press the CLOCK ADJUST button Fig 6 amp operating range becomes appreciably Use the tip of a ball point pen or other small object to press the button reduced replace the batteries and press the RESET button with the tip of a ballpoint 2 Use the TIMER SET buttons Fig 6 to Pen or other small object adjust the clock to the current time button Press to advance the time button Press to reverse the time Set the Current Each time the buttons are pressed the time will be advanced reversed in one minute increments hold the buttons depressed to change the time quickly in ten minute incremen
8. bout 3 minutes preventing unit operation during that period Noise is heard During operation and immediately after stopping the unit the sound of water flowing in the air conditioner s piping may be heard Also noise may be particularly noticeable for about 2 to 3 minutes after starting operation sound of coolant flowing During operation a slight squeaking sound may be heard This is the result of minute expansion and contraction of the front cover due to temperature changes Smells Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner Mist or steam are During Cooling or Dry operation a thin mist may be seen emitted emitted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner resulting in condensation and misting Airflow is weak or stops The fan may operate at very low speed during Dry operation or when the unit is monitoring the room s temperature During SUPER QUIET operation the fan will operate at very low speed In the monitor AUTO operation the fan will operate at very low speed En 14 TROUBLESHOOTING Symptom Items to check See Page k Doesn t operate at all Is the Power Supply Plug disconnected its outlet Has there been a powe
9. cO FUJITSU INVERTER COOL MODEL ROOM AIR CONDITIONER WALL MOUNTED TYPE Indoor Unit ASBA30JFC Outdoor Unit AOBR30JFT KEEP THIS OPERATION MANUAL FOR FUTURE REFERENCE GUARDE ESTE MANUAL DE USO PARA FUTURAS CONSULTAS GUARDE ESTE MMANUAL DE FUNCIONANENTO PARA REFERENCIA FUTURA FUJITSU GENERAL LIMITED OPERATING MANUAL MANUAL DE FUNCIONAMIENTO MANUAL DE INSTRU ES 2 P N9315345325 03 Portugu s Espafiol English CONTENTS SAFETY 6 222 2 2 1 En 1 MANUAL AUTO En 9 FEATURES AND FUNCTIONS En 2 ADJUSTING THE DIRECTION OF NAME OF PARTS AIR CIRCULATION 2t teens ierit teet SWING OPERATION OPERATION tortor tt fe CLEANING AND 2 2 2 En 11 TIMER OPERATION tne nre En 8 TROUBLESHOOTING aun Q uQ sua En 14 SLEEP TIMER En 9 OPERATING TIPS tenen 15 SPECIFICATIONS Lu u 16 SAFETY PRECAUTIONS N DANGER N CAUTION En 1 Do not attempt to install this air conditioner by yourself This unit contains no user serviceable parts Always consult authorized service sonnel for repairs When movin
10. d separately POLYPHENOL CATECHIN AIR CLEANING FILTER UTR FA13 1 Negative air ions deodorizing filter UTR FA13 2 1 Open the Intake Grille and remove the Air filters Air Filter Right amp Left 2 Replace them by two new Air cleaning filters Remove the old air cleaning filters in reverse order of their installation Install in the same way as for installation of the air cleaning filter set 3 Install the two Air filters and close the Intake Grille Air Filter Right amp Left In regard to the Air Cleaning Filters POLYPHENOL CATECHIN AIR CLEANING FILTER one sheet The Air Cleaning Filters are disposable filters They can not be washed and reused For storage ofthe Air Cleaning Filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every three months Please buy delicated air cleaning filters UTR FA13 1 Sold separately to exchange the used dirty air cleaning filters Negative air ions deodorizing filter one sheet light blue The filters should be exchanged about every three years so as to maintain the deodorizing effect Filter frame is not a one off product Please buy delicated deodorizing filter UTR FA13 2 Sold separately when excha
11. er uses static electricity to clean the air of fine particles and dust such as tobacco smoke and plant pollen that are too small to see The filter contains catechin which is highly effective against various bacteria by suppressing the growth of the bacteria ad sorbed by the filter Note that when the air cleaning filter is installed the amount of air produced decreases causing a slight decrease in the air conditioner s performance NEGATIVE AIR IONS DEODORIZING FILTER It comprises pottery super micro particles which can produce negative air ions having the effect of deodorizing and can absorb and remit the peculiar smell at home The optional wired remote controller model No UTB YUD can be used When you use remote controller there are following different points as compared with using wireless remote controller The additional functions for wired remote controller Weekly timer Temperature set back timer The restricted functions for wired remote controller ECONOMY MAINTENANCE 6 THERMO SENSOR And you can t use both wired remote controller simultaneously Only one kind can be selected En 2 NAME OF PARTS Fig 1 7 MANUAL AUTO Fig 2 37 Q x 2 9 OPERATION C gt TIMER 2 08 2 SUPER QUIET C2 7 1 0 Fig 5 b
12. erature will not appear on the Remote Controller s Display About three seconds later the entire display will reappear The thermostat setting should be considered a standard value and may differ some what from the actual room temperature To Set the Fan Speed Press the FAN button Fig 6 09 Each time the button is pressed the fan speed changes in the following order gt AUTO gt HIGH MED LOW gt QUIET About three seconds later the entire display will reappear When set to AUTO Cooling As the room temperature approaches that of the thermostat setting the fan speed becomes slower Fan The fan runs at the low fan speed The fan will operate at a very low setting during Monitor operation SUPER QUIET Operation When set to Quiet SUPER QUIET Indicatior Lamp orange Fig 3 will right SUPER QUIET operation begins The indoor unit s airflow will be reduced for quieter operation SUPER QUIET operation cannot be used during Dry mode The same is true when dry mode is selected during AUTO mode operation During Super Quiet operation Cooling performance will be reduced somewhat If the room does not cool down when using SUPER QUIET Operation please adjust the air conditioner s Fan Speed gt SWING v Example When set to COOL E 4 SET ye SLEEP Y 2 SWING CJ Example When set to 26 C
13. g consult authorized service personnel for disconnection and installation of the unit Do not become excessively chilled by staying for lengthy periods in the direct cooling airflow Do not insert fingers or objects into the outlet port or intake grilles Do not start and stop air conditioner operation by disconnecting the power supply cord and so on Take care not to damage the power supply cord In the event of a malfunction burning smell etc immediately stop operation discon nect the power supply plug and consult authorized service personnel Provide occasional ventilation during use Do not direct air flow at fireplaces or heating apparatus Do not climb on or place objects on the air conditioner Do not hang objects from the indoor unit Do not set flower vases or water containers on top of air conditioners Do not expose the air conditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power source when not using the unit for extended periods Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the air flow Do not drink the water drained from the air conditioner Do not use in applications involving the storage of foods plants animals precision equipment or art works Do not apply any heavy pressure to radiator fins Operate only with a
14. ir filters installed Do not block or cover the intake grille and outlet port Ensure that any electronic equipment is at least one metre away from either the indoor or outdoor units Avoid installing the air conditioner near a fireplace or other heating apparatus When installing the indoor and outdoor unit take precautions to prevent access to infants Do not use inflammable gases near the air conditioner This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety children should be supervised to ensure that they do not play with the appliance FEATURES AND FUNCTIONS INVERTER At the start of operation a large power is used to bring the room quickly to the desired temperature Afterwards the unit automatically switches to a low power setting for economic and comfortable operation AUTO CHANGEOVER The operation mode cooling dry is switched automatically to maintain the set temperature and the temperature is kept constant at all times PROGRAM TIMER The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a
15. n to the setting before swing was begun About Swing Operation Up down swing Swing operation begins using the follow Left right swing The airflow direction louvers move swing ing range according to the current airflow direction in the left right airflow direction Airflow direction is 1 4 for cooling dry With the upper airflow direction louver in the horizon tal position the lower airflow direction louver moves swings to direct airflow to a wide area Up down left right swing The airflow direction louvers move swing in both the up down and left right airflow directions The SWING operation may stop temporarily when the air conditioner s fan is not operating or when operating at very low speeds If the SET button Vertical is pressed during the up down swing operation the up down swing operation will stop and if the SET button Horizontal is pressed during the left right swing operation the left right swing operation will stop CLEANING AND CARE Before cleaning the air conditioner be sure to turn it off and disconnect the Power Supply Cord CAUTION Be sure the Intake Grille Fig 1 is installed securely When removing and replacing the air filters be sure notto touch the heat exchanger as personal injury may result To avoid excessive wear of the part and components or malfunctioning of the air conditioning the user consumer shall perform pre
16. ndoor Unit has started operating and the airflow direction louvers have stopped mov ing Vertical Air Direction Adjustment ANDANGER Never place fingers or foreign objects inside Press the SET button Vertical Fig 6 68 the outlet ports since the internal fan oper Each time the button is pressed the air direction range will change as follows ates at high speed and could cause personal injury Always use the Remote Controller s SET button to adjust the vertical airflow louvers Attempting to move them manu ally could result in improper operation in this case stop operation and restart The louvers should begin to operate properly again Types of Air flow Direction Setting Q During Cooling Dry modes During Fan mode The Remote Controller s display does not change During Cooling and Dry modes do not move the vertical air direction louvers outside their proper operating range for the mode and into the fan region using the louvers in the fan re gion will cause moisture to condense near the air outlet and water may drop onto Use the air direction adjustments within the ranges shown above the floor During the Cooling Dry modes The vertical airflow direction is set automatically as shown in accordance with the type if the louvers are operated outside the of operation selected range 1
17. nging the filters Maintenance of Deodorizing Filters In order to maintain the deodorizing effect please clean the filter in the follow way once three months 0 Remove the deodorizing filter Clean with water and dry in the air 1 Flush the filters with high pressure hot water until the surface of the filters are covered with water Please flush with diluent neutral detergent Never wash by reaming or rubbing otherwise it will damage the deodorizing effect 2 Rinse with water flow 3 Dry in shade 3 Reinstall the deodorizing filter TROUBLESHOOTING WARNING In the event of a malfunction burning smell etc immediately stop operation turn off the electrical 5 breaker or disconnect the power supply plug and consult authorized service personnel Merely turning off the unit s power switch will not completely disconnect the unit from the power source Always be sure to turn off the electrical breaker or disconnect the power supply plug to ensure that power is completely off Before requesting service perform the following checks Symptom Problem See Page NORMAL Doesn t operate immedi If the unit is stopped and then immediately started again the com FUNCTION ately pressor will not operate for about 3 minutes in order to prevent fuse blowouts Whenever the Power Supply Plug is disconnected and then recon nected to a power outlet the protection circuit will operate for a
18. o prevent excessive cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in accordance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is automatically raised 1 C every 1 hour When the thermostat has been raised a total of 2 C the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner auto matically turns off SLEEP timer setting Set time 1 hour MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the event the Remote Controller is lost or otherwise unavailable How To Use the Main Unit Controls When the air conditioner is operated with the controls on the Main Unit it will oper Press the MANUAL AUTO button Fig 2 2 on the main unit ate under the same mode as the AUTO control panel mode selected on the Remote Control To stop operation press the MANUAL AUTO button Fig 2 2 once again Unit see page 7 Controls are located inside the Open Panel The fan speed selected will be AUTO and the thermostat setting will be stand ard 24 C En 9 ADJUSTING THE DIRECTION OF AIR CIRCULATION Adjust the up down left and right AIR directions with the AIR DIRECTION buttons on the Remote Controller Use the AIR DIRECTION buttons after the I
19. p operation at the new its previous mode when the power is restored time setting In the event that this kind of timer fault occurs the Operated by setting before the power failure TIMER Indicator Lamp will flash see Page 3 Use of other electrical appliances electric shaver etc or nearby use of a wireless radio transmitter may cause the air conditioner to malfunction In this event temporarily discon nect the Power Supply Plug reconnect it and then use the Remote Controller to resume operation Temperature and Humidity Range V Cooling Mode Dry Mode Outdoor temperature About 18 to 46 C About 18 to 46 C Indoor temperature About 18 to 32 C About 18 to 32 C If the air conditioner is used under higher temperature conditioner than those listed the built in protection circuit may operate to prevent internal circuit damage Also during Cooling and Dry modes if the unit is used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humidity conditions condensation may form on the surface of the indoor unit and drip onto the floor or other objects underneath About 8096 or more if the outdoor temperature is lower than the
20. p Air Conditioner Operation while the Timer is Operating Press the START STOP button To Change Operating Conditions If you wish to change operating conditions Mode Fan Speed Thermostat Setting SUPER QUIET mode after making the timer setting wait until the entire display reappears then press the appropriate buttons to change the operating condition desired En 8 SLEEP TIMER OPERATION Unlike other timer functions the SLEEP timer is used to set the length of time until air conditioner operate is stopped To Use the SLEEP Timer xx 5 5 To Cancel the Timer While the air conditioner is operating or stopped press the 56 TIMER MODE button to select CAN SLEEP button Fig 609 CEL N The indoor unit s OPERATION Indicator Lamp red Fig 3 lights and the TIMER The air conditioner will return to normal Indicator Lamp green Fig 3 light operation To Stop the Air Conditioner During To Change the Timer Settings Timer Operation Press the START STOP button Press the SLEEP button Fig 609 once again and set the time using the TIMER SET buttons Fig 6 Set the time while the Timer Mode Display is flashing the flashing will continue about five seconds button Press to advance the time button Press to reverse the time About five seconds later the entire display will reappear About the SLEEP Timer T
21. r failure Has a fuse blown out or a circuit breaker been tripped Is the timer operating 8 9 Poor Cooling perform Is the Air Filter dirty Air the conditioner s intake grille or outlet port blocked Did you adjust the room temperature settings thermostat rectly Is there a window or door open 2 Inthe case of Cooling operation is a window allowing bright sunlight to enter Close the curtains In the case of Cooling operation are there heating apparatus and computers inside the room or are there too many people in the room Is the unit set for SUPER QUIET operation 6 The unit operates Are the Remote Controller s batteries dead differently from the Remote Are the Remote Controller s batteries loaded properly 5 Controller s setting If the problem persists after performing these checks or if you notice burning smells or both the ORERATION Indicator Lamp Fig 3 and the TIMER Indicator Lamp Fig flashes or only the TIMER Indicator Lamp Fig flashes immediately stop operation disconnect the Power Supply and consult authorized service personnel OPERATING TIPS AUTO Restart In Event of Power Interruption The air conditioner power has been interrupted by a power if a power failure occurs during TIMER operation the timer will failure The air conditioner will then restart automatically in be reset and the unit will begin or sto
22. r from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operation is indicated by the arrow in the Remote Controller s Display OFF ON or OFF ON One example of Program timer use might be to have the air conditioner automatically stop OFF timer after you go to sleep then start ON timer automatically in the morn ing before you arise To Cancel the Timer Use the TIMER button to select CANCEL The air conditioner will return to normal operation To Change the Timer Settings Perform steps 2 and 3 To Stop Air Conditioner Operation while the Timer is Operating Press the START STOP button To Change Operating Conditions If you wish to change operating conditions Mode Fan Speed Thermostat Setting SUPER QUIET mode after making the timer setting wait until the entire display reappears then press the appropriate buttons to change the operating condition desired To Cancel the Timer Use the TIMER MODE button to select CAN CEL The air conditioner will return to normal opera ion To Change the Timer Settings 1 Follow the instructions given in the section To Use the ON Timer or OFF Timer to select the timer setting you wish to change 2 Press the TIMER MODE button to select either OFF ON or OFF ON To Sto
23. s Fig 6 65 to adjust the desired OFF time or ON time Set the time while the time display is flashing the flashing will continue for about five seconds button Press to advance the time button Press to reverse the time About five seconds later the entire display will reappear To Use the Program timer 1 2 Press the START STOP button Fig 6 62 if the unit is already operating proceed to step 2 The indoor unit s OPERATION Indicator Lamp red Fig 3 5 will light Set the desired times for OFF timer and ON timer See the section To Use the ON timer or OFF timer to set the desired mode and times About three seconds later the entire display will reappear The indoor unit s TIMER Indicator Lamp green Fig 3 will light Press the TIMER MODE button Fig 6 02 to select the PROGRAM timer operation OFF ON or OFF will display The display will alternately show OFF timer and ON timer then change to show the time setting for the operation to occur first The program timer will begin operation If the ON timer has been selected to operate first the unit will stop operating at this point About five seconds later the entire display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer o
24. temperature scope in the list above in order to keep safety operation of device the outdoor unit may stop operation for certain period of time En 15 SPECIFICATIONS MODEL INDOOR UNIT ASBAGOJFC OUTDOOR UNIT COOLING POWER 220 V 60 Hz COOLING RW 791 CAPACITY BTU R 27 000 POWER INPUT KW 2 32 CURRENT 1077 17 0 ENERGY EFICIENCY RATIO KW KWI 3 41 INDOOR UNIT mh 1 100 OUTDOOR UNIT mvh 3 600 MAX PRESSURE MPa 4 12 REFRIGERANT R410A kg 1 90 DIMENSIONS amp WEIGHT NET INDOOR UNIT HEIGHT mm 320 WIDTH mm 998 DEPTH mm 228 WEIGHT kg 14 OUTDOOR UNIT HEIGHT Imm 830 WIDTH mm 900 DEPTH mm 330 WEIGHT kg 58 En 16 co FUJIISU 1 wasaki 213 8502
25. ts 3 Press the CLOCK ADJUST button Fig 6 63 again This completes the time setting and starts the clock To Use the Remote Controller The Remote Controller must be pointed at signal receiver Fig 1 0 to operate cor rectly Operating Range About 7 meters When a signal is properly received by the air conditioner a beeping sound will be heard if beep is heard press the Remote Controller button again Remote Controller Holder Slide up Pull out w Screws vf D Mount the Holder Set the Remote Controller 8 Toremove the Remote Con troller when use at hand En 5 OPERATION To Select Mode Operation 1 Press the START STOP button Fig 6 62 The indoor unit s OPERATION Indicator Lamp red Fig 3 will light The air conditioner will start operating 2 Press the MODE button Fig 6 to select the desired mode Each time the button is pressed the mode will change in the following order gt AUTO COOL DRY FAN About three seconds later the entire display will reappear To Set the Thermostat Press the SET TEMP button Fig 6 62 4 button Press to raise the thermostat setting button Press to lower the thermostat setting G Thermostat setting range s teer e 18 30 C Coolirig Dry ecce 18 30 C The thermostat cannot be used to set room temperature during the FAN mode the tem p
26. twenty four hour period SLEEP TIMER When the SLEEP button is pressed during cooling mode the ther mostat setting is gradually raised during the period of operation When the set time is reached the unit automatically turns off WIRELESS REMOTE CONTROLLER The Wireless Remote Controller allows convenient control of air conditioner operation HORIZONTAL AIRFLOW For cooling use horizontal airflow so the cool air does not blow directly on the occupants in the room WIRED REMOTE CONTROLLER OPTION OMNI DIRECTIONAL AIR FLOW SWING OPERATION Three dimensional control over air direction swing is possible through dual use of both an UP DOWN air direction swing and RIGHT LEFT air direction swing Since UP DOWN air direction flaps operate automatically according to the operating mode of the unit it is possible to set air direction based on the operating mode REMOVABLE OPEN PANEL indoor unit s Open Panel can be removed for easy cleaning and maintenance MILDEW RESISTANT FILTER The AIR FILTER has been treated to resist mildew growth thus allowing cleaner use and easier care SUPER QUIET OPERATION When the FAN button is used to select QUIET the unit begins super quiet operation the indoor unit s airflow is reduced to produce quieter operation POLYPHENOL CATECHIN AIR CLEANING FILTER The polyphenol catechin air cleaning filt
27. ud SG Lm Fig 6 TIMER Ji 83 CLOCK TEST ADJUST RUN RESET Fig 7 To facilitate explanation the accompanying illustra tion has been drawn to show all possible indicators in actral operation however the display will only show those indicators appropriate to the current operation N En 3 NAME OF PARTS Fig 1 Indoor Unit Fig 6 Remote Controller D Operating Control Panel Fig 2 G MANUAL AUTO button When kept on pressing the MANUAL AUTO button for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized service personnel s use When the forced cooling operation starts by any chance press the START STOP button to stop the operation Indicator Fig 3 Remote Control Signal Receiver OPERATION Indicator Lamp red TIMER Indicator Lamp green ifthe TIMER indicator lamp flashes when the timer is operating it indicates that a fault has occurred with the timer setting See Page 15 Auto Restart SUPER QUIET Indicater Lamp orange Intake Grille Fig 4 9 Front Panel Air Filter Air Flow Direction Louver 2 Power Diffuser 3 Right Left Louver behind Air Flow Direction Louver Drain Hose Air Cleaning Filter Fig 5 Outdoor Unit
28. ventive maintenance through an accredited technical assistance periodically To know the preventive maintenance periodicity the consumer shall check with the accredited installer or an accredited technical assistance When used for extended periods the unit may accumulate dirt inside reducing its performance We recommend that the unit be inspected regularly in addition to your own cleaning and care For more information consult authorized service personnel It is recommended for the user consumer to demand copy of the Work Order every time there is a visit of a technical assistance for verification maintenance test or repair of the product When cleaning the unit s body do not use water hotter than 40 C harsh abrasive cleansers or volatile agents like benzene thinner Do not expose the unit body to liquid insecticides or hairsprays When shutting down the unit for one month or more first allow the fan mode to operate continuously for about one half day to allow internal parts to dry thoroughly En 11 CLEANING AND CARE Cleaning the Intake Grille 1 Remove the Intake Grille CD Place your fingers at both lower ends of the grille panel and lift forward if the grille seems to catch partway through its movement continue lifting upward to remove Pull past the intermediate catch and open the Intake Grille wide so that it become horizontal Intake Grille