Home

- INTEG Process Group

image

Contents

1. c 1 c 5 cl 1 5 c1234 c1368 0125 close relay output 1 close relay output 9 first output on first expansion module close relay output 13 first output on second expansion module combination of the above all in one command close relay outputs 1 through 4 close relay outputs 1 3 6 8 open relay outputs 1 2 5 cl lp 1000 close relay outputs 1 9 and pulse each for 1 second simultaneously JNIOR A Network I O Resource Analog Presets Program Manual Release 1 2 Summary INTEG Process Group Inc Thank you for purchasing the JNIOR Hopefully this manual made the getting to know process of your new JNIOR very quick and easy The JNIOR has many more wonderful tools and features available and are explained in detail in the supplied documents Copyright Notice Trademarks Use Restrictions Copyright 2011 INTEG Process Group Inc All rights reserved Every effort was made to make this manual as accurate and useful as practical at the time of the writing of this manual However all information is subject to change Trademarks are the property of their respective holders Sun Sun Microsystems the Sun logo and Java are trademarks or registered trademarks of Sun Microsystems Inc in the United States and other countries Microsoft Windows MS DOS and Internet Explorer are registered trademarks of Microsoft Corporation HyperTerminal is a registered trademark of Hilgraeve Inc This User s Ma
2. have completed the saving of all your changes to flash memory and some may be lost Please implement a soft reboot either from the About tab in the Main JNIOR Web page or by typing reboot in the Command Line tab or a Telnet or HyperTerminal session JNIOR A Network I O Resource 7 Analog Presets Program Manual Release 1 2 INTEG Process Group Inc A APPENDIX Relay Output Control Commands The following commands can be used for the RelayOutputAction value in each Level cX oX p yyy c o Close the output relay is on closing the contact where x through 8 for the internal relay outputs on the JNIOR 310 and x 1 through 8 for the external relay outputs on the 4 Relay Output Expansion Modules Open the output relay is off opening the contact where x through 8 for the internal relay outputs on the JNIOR 310 and x 1 through 8 for the external relay outputs on the 4 Relay Output Expansion Modules Pulse duration milliseconds and is used in conjunction with the close or open command Examples c2p 1000 close output 2 for 1 second and then open again c 2p 1000 close output 10 for 1 second and then open again o3p 10000 open output 3 for 10 seconds and then close again Close all outputs at the same time includes internal and external Open all outputs at the same time includes internal and external These commands can be abbreviated and used in combination such as cl
3. program is program that runs on the JNIOR that allows the user to implement from 1 to 16 levels of analog control values that can be sent to the analog output on the JNIOR analog expansion modules The program works with the 0 10 VDC analog expansion module and the 4 20 mA analog expansion module It will work with one or two analog expansion modules per JNIOR They can both be the same type of module or one of each type 2 The Purpose of the Analog Presets Program The Analog Presets Program is meant to be a stepped analog control solution with relay output control It is not a complete logic controller but rather a way to allow the user to define specific analog values to be sent whenever a trigger occurs The trigger can be a change in state of a digital input or relay output The amount of time it takes to transition from the current analog level to the new analog level can be adjusted 3 Installing the Analog Presets Program The Analog Presets Program is an add on program INTEG distributes the program via an Update Project that is used with the JNIOR Support Tool The JNIOR Support Tool and Analog Presets Program Update Zip can both be downloaded from the INTEG website www integpg com or by contacting INTEG When you run the Update Project the project will load the software set the program to run on boot and cause the JNIOR to reboot so the program is started 4 Configuring the Analog Presets Program After the Analog
4. Cintes JNIOR Utilizing the JAVA P latform process group inc JNIOR Series 3 A Network I O Resource Utilizing the JAVA Platform Analog Presets Program Manual Release 1 2 NOTE JNIOR OS 3 4 or greater required INTEG Process Group Inc 2919 East Hardies Rd First Floor Gibsonia PA 15044 PH 724 933 9350 FAX 724 443 3553 www integpg com JNIORsales integpg com 2011 INTEG Process Group Inc All Rights Reserved Last updated on March 15 2011 INTEG Process Group Inc TABLE OF CONTENTS 1 What is the Analog Presets Program ccesccessececssececesececssececsseceessccecssceecesceeesees 3 2 The Purpose of the Analog Presets Program sesesssesssesessseessseesseessessseresseeesseesseese 3 3 Installing the Analog Presets Program sssseseeseseseesessrssresressessresressersresreesreseeseresee 3 4 Configuring the Analog Presets Program eeeseseeseeseeeseereesresreseressrsersrresseseresreesesee 3 AW Global Transition TMe assays sesteyatcsinntlsdetedhonapranysgus save aente e aae a 4 AD bevels enan clues bites Wen cade RN A a a E RO VAA aA 5 5 Utilizing Your New Settings esiaine asasi ua seamed aS a aT tiaisia 7 A APPENDIX Relay Output Control Commands sseeeeeseeeeeeseeesseresseseresressereresrerseeee 8 JNIOR A Network I O Resource 2 Analog Presets Program Manual Release 1 2 INTEG Process Group Inc 1 What is the Analog Presets Program The Analog Presets
5. Data AnalogPresets Quit false D BootTime AppData AnalogPresets Started Tue Mar 15 15 04 21 GMT 2011 D Model AppData AnalogPresets EmbeddedBaseVersion v 1 1 1111 1342 Bi SerialNumber AppData AnalogPresets ersion AppData AnalogPresets Levels 4 AppData AnalogPresets Name AnalogPresets C4 AppDatal AppData AnalogPresets Version 1 1 1124 1603 CJ AnalogPresets C sauit C Started EmbeddedBaseVersiot D GlobalTransitionTime gt 4 Level_1 E Level_2 c Level_3s o c Level_4 B Levels Bi Name D Version gt CJ Beacon gt C Devices gt C Externalss gt ci lor gt CI IpConfig 4 4 1 Global Transition Time The Global Transition Time is the amount of time in milliseconds that the JNIOR will take to make the transition from the current analog output value being used by the module to the new value defined in the Level that was triggered The JNIOR will make this transition in steps of approximately equal amounts until the new value is reached The Global Transition Time applies to all levels Registry Key Value Global Transition Time Any whole number no decimal place Value is the time in milliseconds Default value is 5000 milliseconds 5 seconds 0 indicates an immediate sending of the new value JNIOR A Network I O Resource 4 Analog Presets Program Manual Release 1 2 INTEG Process Group Inc 4 2 Levels The Analog Presets Program can h
6. Presets Program has been loaded on to the JNIOR and rebooted the Analog Presets Program can be configured via the Main JNIOR Web page The JNIOR must also be rebooted after each configuration change to the Analog Presets program so that the new values are used The web interface makes it easy to define each level of control and to adjust the transition time All the edits are made from the Registry Editor tab To launch the Main JNIOR Web page type the IP address of your JNIOR in your Web browser address line An example is as follows http 10 0 0 208 When you launch the Main JNIOR Web page you may be asked to log in This will depend upon if you have configured your main JNIOR web page for automatic Autonomous log in or not If you have to log in please use the default JNIOR username jnior and password jnior or one that you have created JNIOR A Network I O Resource 3 Analog Presets Program Manual Release 1 2 INTEG Process Group Inc After the Main JNIOR Web page has loaded click on the Registry Editor tab When this has loaded in the left column click on the AppData folder and then the AnalogPresets folder You will see all the Registry Keys associated with the Analog Presets Program as shown below VO Control Configuration Registry Editor Command Line i Applications l About Add Key Edit Key Delete Folder Delete Key Refresh ja App
7. Trigger not set c AppDatal C AnalogPresets Ly SQuit LY Started C ErbeddedBaseVersion Bi GlobalTransitionTime Cj Level_1 D 10vOutputChannel 4200utputChannel Bi RelayOutputAction G Setting Bi Trigger C Level_2 JNIOR A Network I O Resource 5 Analog Presets Program Manual Release 1 2 Registry Key 10vOutput Channel 420Output Channel RelayOutputAction Setting Trigger INTEG Process Group Inc Value Indicates the channel on the 0 10 VDC module Acceptable values 1 2 3 or 4 1 indicates it is NOT USED 1 and 2 are the outputs on the first 0 10 expansion module 3 and 4 are the outputs on the second 0 10 expansion module Indicates the channel on the 4 20 mA module Acceptable values 1 2 3 or 4 1 indicates it is NOT USED 1 and 2 are the outputs on the first 4 20 expansion module 3 and 4 are the outputs on the second 4 20 expansion module Control action for one or more relay outputs Acceptable values See Appendix A For example a value of cl would close output 1 A value of ol would open output 1 A value of clp 1000 would pulse closed output 1 for 1 second Any positive number and it can contain a decimal place The number represents the percentage of output The 0 10 VDC output ranges from 0 0 to 10 VDC 100 The 4 20 mA output ranges from 4 0 to 20 mA 100 Acceptable values 0 00 to 100 00 For example 45 or 45 5 is valid Digital i
8. ave up to 16 different levels Each level can contain a different analog output to be controlled either a 10 VDC output or a 4 20mA output but NOT both for the same level a relay output or multiple outputs to be controlled a value for the analog output Setting and a trigger Trigger that causes the value to be sent to the analog expansion module Registry Keys for four 4 levels are created by default The user can create additional levels via the Registry Editor by modifying the Levels Registry Key AppData AnalogPresets GlobalTransitionTime 5000 AppData AnalogPresets Registry Key Value Levels Any whole number between 1 and 16 default 4 After you change the desired number of levels of control reboot your JNIOR and the additional folders with the appropriate Registry Keys will be created Level Settings To adjust the settings for a specific level of control click on a Level folder in the left window to view the Registry Keys that can be edited VO Control Configuration Registry Editor Command Line Applications About Add Key Edit Key Delete Folder Delete Key Refresh i AppData AnalogPresets Level_1 10vOutputChannel 1 G BootTime AppData AnalogPresets Level_1 4200utputChannel 1 D Model AppData AnalogPresets Level_1 RelayOutputAction none B SerialNumber AppData AnalogPresets Level_1 Setting 1 D ersion AppData AnalogPresets Level_1
9. nput or relay output that will Trigger the program to send the Setting to the analog output channel Acceptable values dinX where X 1 through 8 for example din1 routX where X 1 through 8 for example rout4 To change any Registry Key click on the key in the right window and then click on the Edit Key button at the top Click OK and the Registry Key will be modified JNIOR A Network I O Resource Analog Presets Program Manual Release 1 2 INTEG Process Group Inc 1O Control Configuration Registry Editor i Command Line Applications About Add Key Edit Key Delete Folder Delete Key Refresh l lt AppData AnalogPresets Level_1 10vOutputChannel 1 i BootTime AppData AnalogPresets Level_1 4200utputChannel 1 G Model AppData AnalogPresets Level_1 RelayOutputAction none Ly SerialNumber AppData AnalogPresets Level_1 Setting 1 D version AppData AnalogPresets Level_1 Trigger not set gt cI AppData c AnalogPresets C Quit Ty Started C ErnbeddedBaseVersio B GlobalTransitionTime c Level_1 D 10vOutputChannel 4200utputChannel l Edit Registry Key hl 5 Utilizing Your New Settings After you have changed any of your Registry Keys the JNIOR must be rebooted to restart the program Please do NOT disconnect the power for the reboot If you disconnect the power too fast the JNIOR may not
10. nual and the software contained in the JNIOR are copyrighted by INTEG Process Group Inc and may not be copied or reproduced without prior consent from INTEG Process Group Inc INTEG Process Group Inc is not responsible for any errors or omissions that may be contained in this manual Please do not hesitate to contact our JNIOR team at INTEG Process Group Inc We can be reached via phone fax or e mail as follows INTEG Process Group Inc 2919 E Hardies Road 1 Floor Gibsonia PA 15044 www integpg com JNIORsales integpg com PH 724 933 9350 extension 20 FAX 724 443 3553 JNIOR A Network I O Resource Analog Presets Program Manual Release 1 2

Download Pdf Manuals

image

Related Search

Related Contents

HabiTEQ - System Manager Software  Samsung C100C Brugervejledning  Ruling, Measuring - Custom Blueprint & Supply  Samsung Mini componente FS9000 Manual de Usuario  Protection auditive  User`s Manual Guide d`Utilisation  取扱説明書  コンベクションレンジ『PCR500ET,PCR500ESVT』    ACL for Windows Version 7 Workbook  

Copyright © All rights reserved.
Failed to retrieve file