1. 9265 300 DryLogger Nov 2009 7 LOGMANAGER Operative Instructions SOFTWARE INSTALLATION If you want to connect the DryLogger to a USB port of your PC you must first install the PL2303 drivers like decribed in the file User s manual pdf located in the directory PL2303 of the installation disk Otherwise if you want to connect the DryLogger to RS232 port of your PC it s sufficient to use a common serial cable The LogManager software don t need any installation simply copy the file LogManager exe a directory of your PC and run it to be operative SETTING THE DRYLOGGER CONNECTION 1 Connect the DryLogger to the PC via RS232 or USB port 2 Enable the DryLogger port see Enabling port 3 Run LogManager pull down the Settings menu and click on COM port select Select the right port from the availables COM1 2 COM3 etc The status of the connection between the DryLogger and the PC is clearly indicated Fi Port Select Com Port com3 Fi Port Select Com Port Port COM1 No MiniLogger or DryLogger connected 1 DryLogger is connected DryLogger is not connected 9265 300 DryLogger Nov 2009 SETTINGS THE DRYLOGGER PARAMETERS Pull down the Datalogger menu and click on Setup to set the time the date and the sample rate of the DryLogger Actual settings 2009 10 27 17 26 24 21600 samples collected from 2009 10 22 14 33 38 Sample rate
2. DryLogger mod 9265 300 INSTRUCTION MANUAL EC CONFORMITY Units 9265 300 conform to EC directives 89 336 EEC the following harmonized standards in use 60204 1 EN 50081 1 EN 50082 1 WARRANTY This unit is guaranteed against all defects due to faulty materials and workmanship within 12 months from the date of purchase A use not conforming to what specified might be dangerous to the safety of the operator and may damage the unit In such circumstances the manufacturer is relieved of any liability and the warranty itself will decay REPAIR Repairs have not been attempted by anyone other than authorized repair distributors Do not try to repair the unit by yourself Protecting the environment Separate collection This product must not be disposed of with normal household waste Should you find one day that your needs replacement or if it is of no further use to you do not dispose of it with household waste Make this product available for separate collection Separate collection of used products and packaging allows materials to be recycled and used again Re use of recycled materials helps prevent environmental pollution and reduces the demand for raw materials Local regulations may provide for separate collection of electrical products from the household at municipal waste sites or by the retailer when you purchase new product GY 2 9265 300 DryLogger Nov 2009 TECH
3. M 05 20 2008 60 2 19 4 09 31 31 AM 05 20 2008 This file can be easily edited into a text editor or imported into a spreadsheet 10 9265 300 DryLogger Nov 2009 PRINTING To print the showed graph pull down the File menu and click on Print OPENING OF A FILE Pull down the menu File click on Open and insert the path of the rec file to open RH PROFILE To know the time amount when the DryLogger was in a determinate zone of RH T is useful to see the RH profile Click on the RH Profile button located in the left bar FARH Profile Set Start End Time From 2009 10 07 14 50 55 To 2009 10 07 20 27 56 RH Profile hours 510 10 20 20 30 3040 4050 5060 60 70 70 80 80 90 90 95 OPTIONS Pull down the menu Settings and click on Preferences to select the desired temperature unit or F and to select the graps s colors Fi Preferences x Humidity m Temperature Temperature scale TC Celsius F Fahrenheit 9265 300 DryLogger Nov 2009 11
4. NICAL FEATURES Precision Temperature Humidity meter It is also a datalogger used to collect environmental data of humidity and temperature and to transfer them to a Windows PC 2000 XP Vista 7 1 to 95 RH Resolution 3 2 0 1 RH dened wd ode werd 2 RH 25 C 10 RH 90 RH die as ee oe Bae eee eB 3 RH 25 C 1 RH 10 9O RH 95 Temperature range 20 C to 60 C Resolution ar OE E EEE eee 0 1 C tenes ewe es od 1 C SENSON yi sae internal eee ees 64Kbyte PONMGAGING seres as 21600 couples of RH and T Samplerate can be setat 1 5 10 15 30 sec Sita eek Gas ae Sue eens Pee eas bE ee ee ees 1 5 10 15 30 min scan ae weer ney ewe seat eee eee ences E RS232 USB LCD Display 48x 11mm DIMENSIONS sine ie cba Gas 184x67x44mm Weih Chee meee ene 320g 4x1 5V IEC type Battery Life it depends on battery capacity ome fees With capacity 2600mAh and the instrument always ON the life is 8 month Low Battery i
5. ff DryLogger keep pressed the ENTER key for 2 seconds ATTENTION Shutting off DryLogger will stop any datalogging activity The instrument stop the sampling activity and save the data collected DISPLAY MODE To set the display to show the humidity press set the display to show alternately the humidity and the temperature press To set the display to show the temperature press To change the temperature unit C or F keep pressed the key for 2 seconds 9265 300 DryLogger Nov 2009 5 DATALOGGER GETTING STATUS 1 Repetitively press PROG until the display will show DL Info 2 Press the ENTER key to know if datalogger is sampling DL Run Y sampling is on DL Run N sampling is off 3 Press the ENTER key to know the sample rate For example SR 1sec means that the sample rate is 1 second 4 Press the ENTER key to know the sample data collected For example S 21600 means that the memory is full and sampling activity is stopped 5 Press the ENTER key to exit from the programming mode During point 2 3 4 5 it s possible to press the EXIT key to exit immediately from the programming mode ERASING MEMORY If memory contains collected data see Getting Status and you want erase them follow the instructions below 1 Repetitively press PROG until the display will show DL Clear 2 Keep pressed the ENTER key for 2 seconds The DryLogger will exit from the programming mode START SAMPLING To start samp
6. is 1 seconds New Settings 2009 10 27 16 28 08 Capacity 21600 samples 1 second v hours The sample duration depends on the sample rate Sample rate Sample duration 1 sec 6 hours 5 sec 1 day and 6 hours 10 sec 2 days and 12 hours 15 sec 3 days e 18 hours 30 sec 7 days e 12 hours 1 min 15 days 5 mini 75 days 10 min 150 days 15 min 225 days 30 min 450 days ATTENTION when you set the new value of date time and sample rate any collected data logged into the DryLogger memory will be erased 9265 300 DryLogger Nov 2009 9 DATA DOWNLOAD Pull down the Datalogger menu and click on Read for downloading and displaying the collected humidity and temperature data FaLogManager frigo rec File Settings Datalogger Help Measuring 9 parameters Humidity RH Temperature From 2009 10 21 09 51 00 2009 10 21 15 50 59 21600 records interval 1 seconds Data analysis Hunidity 93 3 RH Humidity min 0 0 RH Temperature max 23 2 RH Temperature min 24 1 RH RH Profile Time h 09 51 00 gt 2009 10 21 lt 2009 10 21 11 51 00 74 9 RH 20 0 C Immediately after the downloading a message prompt will ask you if you want to save the data The format used to save the data is rec that is a simply text file like this TEMP HUMI TIME Interval 10 Seconds 60 7 19 4 09 31 01 AM 05 20 2008 60 4 19 4 09 31 11 AM 05 20 2008 60 3 19 5 09 31 21 A
7. ling data be sure that the DryLogger memory is clear see Getting status If the memory is not empty erase it see Erasing memory 1 Repetitively press PROG until the display will show DL Start 2 Keep pressed the ENTER key for 2 seconds The DryLogger will exit from the programming mode A switching bar in the 4th position on the display indicates that the datalogger is sampling 4 a STOP SAMPLING If there is a sampling activity and you want to stop 1 Repetitively press PROG until the display will show DL Stop 2 Keep pressed the ENTER key for 2 seconds The Drylogger will exit from the programming mode ATTENTION it s not possible to collect more than 1 session of data Therefore if you want to sample again you must first erase the memory 6 9265 300 DryLogger Nov 2009 ENABLING PORT If there is no sampling activity it s possible to interface the DryLogger and a PC 1 Repetitively press PROG until the display will show Keep pressed the ENTER key for 2 seconds 3 The display will show lt gt DL 4 The DryLogger has now his port enabled If there is no communication activity within 10 minutes the instrument will disable his port to reduce consumption In this case repeat from point 1 DISABLING PORT 1 Repetitively press PROG until the display will show Comm Off 2 Keep pressed the ENTER key for 2 seconds The DryLogger will exit from the programming mode
8. ndication when the battery level falls below 4V CONTENTS 1 DryLogger 2 USB to Serial RS232 adapter cable 3 Installation disk containing PL2303 drivers for the adapter cable LogManager software for downloading displaying analyzing and reporting your collected humidity and temperature data Instruction Manual 9265 300 DryLogger Nov 2009 3 KEYBOARD To display humidity To alternately display the humidity and the temperature To display the temperature To change the temperature unit C or F PROG To enter the programming mode ENTER To confirm the action in the programming mode ON OFF To light up and shut off the instrument EXIT To exit from the programming mode BATTERY REPLACEMENT When Low Batt is displayed you must replace the batteries Open the battery cover located in the backside of the instrument removing the 2 fixing screws Replace the batteries respecting the right polarity see indication Close the battery cover NOTE1 the instrument can work some days when Low Batt is displayed even if datalogger is sampling NOTE2 replace batteries within 1 minute in order to keep data memory and datalogging activity 4 9265 300 DryLogger Nov 2009 OPERATIVE INSTRUCTIONS ON OFF In order to light up DryLogger press ENTER Display will show date time sample rate and sample data collected After these informations the instrument will show humidity and or temperature To shut o