User manual Product name Rhone2 Function Power Control Switch

image

Contents

1. function is software controlled Unless distributed via e mail request latest version of firmware by sending e mail to info skdab se Firmware is upgraded via USB interface a Copy firmware file image hex to USB memory b Turn off power to the product and insert USB memory into Rhone2 USB interface c Hold SW2 and turn on power SW2 will start blinking fast after a couple of seconds Upgrade is complete when blinking stops d If several Rhone2 nodes are installed in the same network reassign the last three digits of MAC address to correspond the MAC address on product label MAC address is reassigned via web under Upgrade via app under About or by command lanmac last three digits in MAC over TCP Alternative 1 Hold SW2 for 15sec until LED2 stops blinking Alternative 2 From skdRhone2 Settings page select Restore icon Alternative 3 From product web page Config page select icon Restore Alternative 4 Via TCP send command restore User Operation C Copyright 2010 2014 SKD System AB 4 RN SKD system AB Operation of AC AC switch can be controlled by switch Manual switch on front panel By external sensors From control system PC and Android by command via TCP From PC and Android via web From Android device via USB or WiFi LEDs on front panel indicate if AC switch is on or off If LED is off AC switch is off Sensor is deactivated If LED is green AC switch is on Activated by command via web
2. EN skp System AB User manual Generated 2015 01 28 Product name Rhone2 Function Power Control Switch Article M3107 1221 B Description Connection to mains 2 x Switched AC ports Integrated E meter SWw2 Restore Firmware upgrade Sw USB control Sensor Sensor2 AC1 LAN control AC2 Connection to mains Features AC switch 16A high inrush E meter Measurement of current range 0 016 to 16 Ampere and power range 4 to 3700 Watt Presence sensor interface LAN control HTTP TCP USB control Android Wieland mini male connector connection to mains Wieland mini female connectors connection of electric equipment WiFi control from Android device via LAN Software controlled fuse in addition to physical fuse Dimensions L220 W100 H30mm Applications Power control on workplace Switching of power to power distribution lists and electrical equipment on workplace One unit can serve one or two workplaces Control via LAN by sensors via USB RN SKD system AB Power distribution ad i Rhone2 So A p a LAN K g i key f Mains I Sensors wa SmartPhone Remote power control Remote control of power switch Power switch can also be controlled by local sensors Equipment e Sensors afety Precautions The product must be connected to earthed AC outlet Do not use damaged AC connecting cables The product may get damaged by AC currents exceding
3. activated by Sensor1 LED2 If off AC2 is disconnected If Green AC2 is turned on activated by SW2 command or via Android If Red Sensor2 is activated and controls AC2 If Orange AC2 is on activated by Sensor2 Fast blinking Green When holding for SW2 for 15 seconds to initiate restoring factory defaults Indirect Connection Over WiFi Connection between skdRhone2 app in Android and the product can be set upp by selecting product IP address in the app See Network page gt Node IP If current IP of the product is not in the Selection list add node address to the list After each change of WiFi connection settings Close app and start app again to ensure that the changes are activated in the app ECLER Rhone2 Connected WiFi rn Set node name Current node address over WiFi Select node address for WiFi Add node address to selection Remove node address from list Current node LAN configuration _ Set new LAN configuration Activate LAN settings update Activate DHCP client Close app Illustration of control of AC switch and sensors via WiFi Gent pe 4 Rhone2 Connected WiFi Main Turn AC switch on off AC switch state Presence Sensor active Current E meter readings Update page Update Wet Help Access product via web Cose Help information Close app C Copyright 2010 2014 SKD System AB 8 AN SKD system AB Connection via USB Cable Product acts as host for Android devices skdRhone2
4. app is implemented for Android devices version 4 0 or later Android 16 or later Other types of devices are not supported at this time To start communication over USB If not installed install app skdRhone2 from Google play Pru ia hone Connected USS AC fuse Type Function Characteristics Handling DC fuse Function Characteristics Handling AC switch Function Connectors Characteristics Mode of operation E meter Function Control Connect USB cable between Android and Rhone2 App and communications start automatically Turn AC switch on off AC switch state Presence Sensor active Current E meter readings Update page Access product via web Help information Close app Technical Specification Physical fuse F2 250Vac T16AH Overcurrent protection Max load on connection to mains 16A Rated current for the physical fuse 0 5A to 16A 250VAC Time lag T Dimensions 5x20mm Non resettable In case AC fuse needs to be replaced replace with Schurter article 0001 2516 or equivalent Replacement of fuse only by service personnel Overcurrent protection on USB and Sensor interfaces Hold current 2A Trip current 4 4A Time to trip at 4 4A is 4sec The fuse is a resettable fuse PTC Fuse increases its internal resistance at overcurrent on internal DC source The fuse resumes normal operation after fault is removed unless device was exposed to conditions outside of its normal operating area Swit
5. After selection Close app and start app again IP address of the product can be verified by connecting Android to the product with USB cable See also LAN control not working Check LAN cable Check that IP address is correct For example by connecting Android to the product via USB cable or via LAN router If LAN configuration was changed reset the product by power on off If IP is not known restore factory defaults Default IP 192 168 1 222 If IP was set via DHCP client check DHCP server for ip address MAC address of the node can be found on the product label Alternatively check IP via app LAN control will not work if two nodes in the LAN have the same IP address If firmware was upgraded verify that the last three digits in MAC address of the product have been reasigned to correspond to the last three MAC digits on product label This can be done by command lanmac via web under Upgrade or via skdRhone2 app About page Make sure the product is reset after MAC reassignment Read IP address from the product by connecting Android device via USB interface Network page displays current network parameters of the product Alternatively Restore product to factory defaults by holding SW1 or SW2 for 15seconds Default ip 192 168 1 222 gateway 192 168 1 1 IP and Gateway address can be set to new values via Android connected to USB or by connecting the product via LAN to PC C Copyright 2010 2014 SKD System AB 12
6. and that mains power is on If it is suspected that physical fuse could have burned out check and if necessary replace the physical fuse with 16A time delay T 5x20mm fuse Replacement of the physical fuse can only be done by service personnel To replace physical fuse unscrew the AC side plate and the Control side plate slide the cover plate towards control plate side until fuse is uncovered Then remove carefully the fuse and replace with new Check for possible short circuit on USB interface or Sensor interface The product has built in resettable DC fuse which will disconnect internal DC power supply in case of overcurrent on USB or Sensor interface The fuse resets automatically after the cause of the overcurrent has been removed This is normal situation when Sensor1 and or Sensor2 are activated When Sensor1 and of Sensor2 are activated manual switch functions SW1 and or SW2 are deactivated To enable manual switching deactivate Sensors This is normal situation when Sensor1 and or Sensor2 are activated If Sensor1 and of Sensor2 are activated command acsw is deactivated To enable command acsw deactivate Sensor function by command psensor Example psensor 1 0 deactivates Sensor1 psensor 2 0 deactivates Sensor2 Check that sensor is activated Sensor is activated via Android Web LAN Check cable between sensor and the Power Control Unit Check that sensor enclosure is not damaged and that sensor is not covered Sensor fu
7. ations script or from application program in the control system Example of communication with the product from PC via TCP by using Python script import sys os socket TCP_PORT 60000 BUFFER_SIZE 5000 TCP_IP 192 168 1 222 s socket socket socket AF_INET socket SOCK_STREAM s connect TCP_IP TCP_PORT s send acsw 1 1 s close Example of command session pra i Examples of commands lanconf acsw psensor Serial Interface Commands Common nodename Read node name nodename name Set node name Up to 12 alphanumerics Example nodename First Set node name to First who Read node id and name help Help lists commands and command groups productdata Read product data states Read device states defaults Read default settings Default settings are parameters reinstated after Restore command C Copyright 2010 2014 SKD System AB N SKD System AB LAN configuration AC switch E meter AutoFuse Presence sensor Manual switch C Copyright 2010 2014 SKD System AB reset Reset dynamic data Reset is equivalent to turn off power and turn on power again Permanent data are not changed by reset restore Restore permanent node data to factory defaults This includes ip address gateway address node name sensor timers autofuse settings h lan Help LAN configuration commands lanconf Read LAN control interface data lanip Read ip address lanip ip Set ip address To acti
8. ching of AC ports Wieland mini connectors 3pins GST15i3 white Male connector for connection to mains Female connector for connection of other AC devices 16A 250V High inrush switched ports Pulse controlled switches Very low power consumption When presence sensor function is deactivated AC switch is turned on off by controls At power on to the product AC switch is turned off whether is was off or on before power on When presence sensor function is activated AC switch controlled by the sensor will be turned on at power on and upon detection of movement AC switch is turned off upon expiration of sensor timer AC meter Measures TrueRMS values of current Calculated values of Power and Energy Measurement range 16mA to 16A 4Watt to 4000Wat Display of results via LAN TCP HTTP via USB Android via WiFi Android C Copyright 2010 2014 SKD System AB 9 AN SKD system AB Presence sensor interface Function Pinout LAN control Function Interface MAC address Defaults Command interface USB control Function Communication Application Supported devices Interface Characteristics Wieland mini male Function Type Characteristics Wieland mini female Function Type Characteristics Indirect WiFi control Function Characteristics AutoFuse Function Defaults Characteristics Control Mode of operation RJ 45 interface Use patch cable to connect sensor Pin 4 Sensor signal P
9. he user or use sensor with wider coverage NOTE At power on sensor calibrates itself automatically to the evironment This takes around half minute Download app skdRhone2 from Google Play Connect Android device to Rhone2 using USB cable skdRhone2 starts automatically when USB cable is connected Android device is normally notified by Google play on skdRhone2 uppdates Otherwise check Google play for latest release Standard configuration If local gateway ip address is 192 168 1 1 connect Rhone2 to LAN with path cable and turn on power Rhonez is ready for operation Access modes Web page http Can be accessed from PC control system Android Default link http 192 168 1 222 TCP port 60000 Can be accessed from PC control system Android Use Serial Terminal application in PC TCP can also be accessed directly from PC application from app or via scripted interfaceThere are also many examples of script interface There are many simple examples of how to communicate over serial interface using scripting language Python Indirect WiFi access from laptop PC or Android For access from Android use app skdRhone2 which can be downloaded from Google play Configure Rhone2 LAN from Android SmartPhone or Tablet Install skdRhone2 app When Android device is connected to Rhone2 with USB cable the app will start and connect to Rhone2 automatically Next select Network page and set New IP New Gateway and or New MASK Next select Acti
10. in 5 5V power supply to sensor Pin 6 Ground Command interface over TCP port 60000 HTTP server port 80 Ethernet RJ 45 connector SKD System AB MAC address space 00 50 C2C59XXX MAC address is printed on the product label MAC address can be read via Web interface or via app Factory settings IP 192 168 1 222 GW 192 168 1 1 MASK 255 255 255 0 Serial interface commands are listed in User Manual product app and product web page USB host interface Charging of connected USB devices Android Open Accessory Protocol 2 0 with extensions Control of the product by app in Android device Upgrade of firmware from USB memory Android smart phones and tablets version 4 1 or higher USB A connector Max charging current on USB interface 0 5A USB DC supply leads are protected from overload by internal fuse of 2A DC AC connector for connection to mains Wieland Gesis mini GST15i3 male Rated 16A color white AC connector for connection of user equipment Wieland Gesis mini GST15i3 female Rated 16A color white Communication via WiFi from Android device indirectly via LAN Communication between the Android app and the product over WiFi starts automatically when app is activated Software controlled fuse Complement to the 16A physical fuse integrated into the product AutoFuse disconnects power on both L and N lines when current to the product exceeds a preset threshold level in Ampere for the time period in second
11. nction is verified by moving hand in front of sensor Sensor should turn red when movement is detected Note Sensor calibrates itself at power on For best performance minimize movement around sensor during calibration period This takes around 30seconds Make sure that sensor opening is oriented towards the area where movement is to be detected Try sensor with larger opening Note Sensor certain time to detect movement Fast movement in front of sensor may not provide sufficient signal to the Sensor to detect movement Sensor sensitivity can therefore increase if sensor is placed further away from the movement Check USB cable Try by reconnecting USB cable Check that app for the product is installed on Android Try closing app and opening it again In some cases several instances of app activity could be running in parallel Try closing app from Android In some Android products this can be done by holding Home button for a second and when running apps get displayed swipe away the app C Copyright 2010 2014 SKD System AB 11 AN SKD system AB No connection over WiFi from Android LAN control not working IP of the product not known Check that the product is connected to LAN and that Android is connected to LAN via WiFi Connection of the product to LAN can be verified via w eb browser Default link to product web page http 192 168 1 222 Check that Node IP address in app is correct or select the correct Node IP
12. new gateway Example langw 192 168 7 1 lanmask Set new ip Example lanmask 255 255 255 0 lanactivate Activate the changes Finally reset Rhone2 by turning power to the product off on Product is delivered with the following settings Gateway IP 192 168 1 1 IP address 192 168 1 222 Network MASK 255 255 255 0 TCP port 60000 DHCP client deactivated MAC address can be found on the product label skdRhone2 app includes extension for communication via WiFi Connection via WiFi is established automatically at activation of the app if Android device is connected to LAN via WiFi product is connected to LAN and communication between Android and Rhonez2 is permitted over local LAN If Android device is connected to Rhone2 via USB cable communication over USB has the priority The product includes in addition to physical 16A fuse also software controlled fuse Automatic fuse is by default enabled Default current limit 16Ampere Default latency 3sec AutoFuse settings can be changed via Web TCP or from app If current through AC switch exceeds preset threshold AutoFuse will turn off AC switch and get into disabled state If disabled enable AutoFuse function to supervise current level NOTE AutoFuse does not block the AC switch function It only turns off AC switch in case current level exceeds the preset threshold NOTE SKD System AB assumes no responsibility or liability for consequences of using AutoFuse function AutoFuse
13. or by manual switch Sensor is deactivated If LED is red AC switch is off Sensor is activated If LED is orange AC switch is on activated by sensor When sensor is active manual control is deactivated Use of USB control Upon connection of USB cable between Android and Rhone2 skdRhonez2 app starts automatically Use of LAN control Web access Enter Rhone2 ip link via web browser Example http 192 168 1 222 TCP access Start communication via TCP port 60000 from Serial Terminal application Example Open Serial Terminal enter product ip 192 168 1 222 port 60000 communications mode RAW Alternatively open communication interface using script or via PC or Android application If indirect connection from Android to Rhone2 over WiFi and LAN exists skdRhone2 will connect automatically via WiFi Use of sensors Activate sensor and set sensor timers via web app or by command via LAN If activated when sensor detects presence it turns on AC switch AC switch is turned off automatically after preset timer period of no presence NOTE At activation of sensor control manual control is deactivated NOTE When power to the unit is turned on sensor will calibrate itself to the environment This takes around 30 seconds For best result minimize movement around sensor during calibration period Use of AutoFuse AutoFuse turns off AC switch when current level exceeds preset current limit for duration set by latency Make sure that AutoFuse i
14. power rating of the product Do not expose the product for excessive cold or heat Do not spill liquids onto the product The product may not work properly after fall to the floor or after other types of mechanical distress Installation Mounting Connect power cables E meter Mount Rhone2 into cabinet backside of desk underneath desk wall or other appropriate place Use velcro closing alternatively metal fixtures Velcro closing is included in delivery Connect product to the mains with cable that has Wieland mini GST15i3 female connector on the product end Connect product to equipment with cables that have Wieland mini GST15i3 male connectors on the product side Note Connecting Wieland cables need to be handled by trained service personnel Not action needed E meter starts measuring current and power automatically when power to Rhone2 is turned on C Copyright 2010 2014 SKD System AB 2 AAN SKD system AB Sensors USB control LAN control Configure LAN from app Configure LAN from web page Connect sensor to Rhone2 with patch cable and determine where to position sensors Move hand in front of the sensor Sensor will turn red at detection of movement When suitable position of the sensor is determined fix sensor to the surface using screws or Velcro closing On workplace sensor will typically be fixed under the workdesk close to the edge If sensor is not reacting as intended move sensor closer to t
15. s set by the fuse latency parameter AutoFuse does not block AC switch from operation after it released To activate AutoFuse after release enable it by command via app or via product web page Default current threshold level for automatic fuse is 16 Ampere and latency 3 seconds After detecting that current exceeds preset limit for latency period AutoFuse disconnects physically both L and N power leads Threshold level and latency of the AutoFuse can be set by command via LAN via Android app or via product Web page If activated AutoFuse function turns AC switches off when current exceeds preset limit for the time set by latency AutoFuse is set to inactive state AC switch is not blocked when AutoFuse is inactive This implies that AutoFuse does not need to be activated for AC switch to work Product Approvals C Copyright 2010 2014 SKD System AB 10 RN SKD system AB Product safety EMC Power consumption Operating temperature Humidity RoHS Disposal Nothing works No controls are working Manual switch not working Command acsw does not switch Sensor not working Sensor not sensitive enough No USB connection EN 60950 1 2006 A1 A2 A11 A12 EN 55022 class A EN 55024 EN 61000 6 2 EN 61000 6 4 Environmental Specification 2Watt 0 degrees C to 40 degrees C 5 to 95 RH non condensing Compliant Dispose for recycling Troubleshooting Check that cable to mains is connected
16. s set to Enabled and that current limit and latency settings correspond to the intended values NOTE AutoFuse does not block the AC switch This implies that if AutoFuse is not enabled AC switch can be turned on or off Use of E meter E meter measures continously TRMS value of the current Power and energy values are calculated For measurement of energy thart the measurement from desired timepoint This can be cone by command emeter 1 1 via web or Android app Use command emeter 1 0 to stop measurement of energy kWh E meter results can be read via LAN Web or Android Web Interface To access product web page open web browser and use ip address as link to the product web page Default link http 192 168 1 222 C Copyright 2010 2014 SKD System AB 5 N SKD system AB EE 5xD system AB Webbeidan kan inte visas ojx 266 Su naoa 0 syren as SKN System AR A Power Control Switch Rhone Noderame Nadai AC switch state qe tum AC switch on off Sensor control Ea Sensor timer 800 Sec Presence Timer countdown 1800 Position 2 Activate sensor AC switch state On Presence detect Present es a Set sensor timer Sensor control on Sensor umer EJ al 2 E E meter results E meter crt aa ey e ___ Start stop kWh meter Update page Command Interface To access command interface start TCP port 60000 This can be done by starting Serial Terminal application in PC by starting communic
17. uselatency id Ampere Set autofuse current latency in Ampere Range 0 16A Example autofuselatency 1 12 Set Autofuse current latency to 12 Ampere autofuse Read autofuse status autofuse id activate Enable Disable fuse Example autofuse 1 1 Enable autofuse1 autofuse 1 0 h psensor Help presence sensor commands psensortimer id sec Set time limit in seconds for presence sensor Range 0 9999sec Timer value is preserved at reset Example psensortimer 1 1800 Set timer to 1800 sec psensor Read presence sensor data psensor id status id 1 2 status 0 1 0 OFF 1 ON Activate deactivate presence sensor Presence 0 Absent 1 Present 2 Sensor deactivated Example psensor 1 1 Activate Sensor1 psensor 1 0 SW1 Turn AC1 on off when AC1 is not controlled by Sensor1 AC1 is controlled by Sensor1 if LED1 is Red RN SKD system AB SW2 Turn AC2 on off when AC2 is not controlled by Sensor2 AC2 is controlled by Sensor2 if LED2 is Red Other functions of SW2 Initite firmware upgrade and restore factory defaults For firmware upgrade Hold SW2 while USB memory with new firmware is inserted into USB interface while powering on the product For restoring factory defaults Hold SW2 for around 15 seconds until fast blinking stops LED function LED1 If off AC1 is disconnected If Green AC1 is turned on activated by SW1 command or via Android If Red Sensor is activated and controls AC1 If Orange AC1 is on
18. vate enter command lanactivate To return to factory defaults use restore command alternatively restore can be done in some product models by pushing manual switch for 10sec See User Manual Example lanip 192 168 1 222 New ip address langw Read gateway ip address langw ip Set gateway ip address To activate enter command lanactivate Example langw 192 168 1 1 New gateway address lanmask Read ip mask lanmask ip Set ip mask To activate enter command lanactivate Example lanmask 255 255 255 0 New MASK address lanactivate Activate new ip address new gateway address and or new ip mask The command activates only ip gw and or mask which do no have value 0 0 0 0 landhcp Read DHCP client status 0 not active 1 active landhcp dhcp Activate deactivate DHCP client After this command reset the node to activate the change Example landhcp 1 Activate DHCP client h acsw Help AC switch commands acsw Read AC outlet states acsw id state Set AC outlet outport id 1 to off 0 or on 1 Example acsw 1 1 Turn on AC1 acsw 1 0 h emeter Help E meter commands emeter Read E meter status and measurement results emeter id activate Start Stop KWH meter Example emeter 1 1 Start KWH meter emeter 1 0 h autofuse Help AutoFuse configuration commands autofuselimit id Ampere Set autofuse threshold in Ampere Range 0 16A Example autofuselimit 1 12 Set Autofuse threshold to 12 Ampere autof
19. vate icon to activate the changes in Rhone2 Finally reset Rhone2 by turning power to the product on off If skdRhonez2 is not installed in Android Install skdRhone2 from Google play skdRhonez is designed for Android version 4 0 and later Configure Rhone2 LAN from PC via web Connect Rhone2 directly to PC with patch cable Via Network configuration in PC set gateway address in PC to 192 168 1 1 Start web browser enter link http 192 168 1 222 Select Config page and set new ip new gateway and or new mask address Then activate the change by selecting Activate icon Only the ip gateway and mask values which are not 0 0 0 0 are activated Finally reset Rhone2 by turning power to the product on off Alternative method of configuring LAN parameters is by activating DHCP client in Rhone2 C Copyright 2010 2014 SKD System AB 3 RN SKD system AB Configure LAN via TCP LAN factory settings WiFi control Automatic fuse Firmware upgrade Restore factory defaults Configure Rhone2 LAN from PC via TCP Connect Rhonez2 directly to PC with patch cable Via Network configuration in PC set gateway address in PC to 192 168 1 1 Start TCP terminal in the PC Set connection parameters ip 192 168 1 222 port 60000 and transfer method RAW When command window opens use the following commands to change LAN configuration lanconf Read current LAN settings lanip Set new ip Example lanip 192 168 7 44 langw Set