Home
WATER LOW FOG
Contents
1. DMX controller Each fixture requires a start address from 1 511 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fixture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 105 and 106 Choose a start address so that the channels used do not overlap E g the next unit in the chain starts at 107 DMX 512 e DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking e DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere i
2. gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available voltage is AC220V Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again lf the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your dealer for service Only use fuses of same type and rating Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks etc Do not endanger your own safety and the safet
3. housing Should you need any spare parts only use genuine parts If defective please dispose of the unusable unit in accordance with the current legal regulations Should you have any further questions please contact your dealer Technical Specifications Fog output 1 0000 cu ft per minute Warm up time First time 5 minutes Fuse 10A 250V Power consumption 1200W Power supply 220V Dimensions 66 40 44CM Weight 40Kgs
4. you can change the volume output by pressing the UP and DOWN buitons Timer Operation To use the timer operation press the TIMER button The timer will now work with the Interval Duration and Volume setting that you have previously set To change any of the settings for these options please follow the steps on the previous page DMX Address Setting There are two methods to set the units DMX address one is pressing the MENU button to show DMX 512 on the LCD display Now use the UP and DOWN buttons to set the desired DMX address from 001 512 another is setting DMX Address through DIP Switch as usually but the DMX Address set through DIP Switch has priority if two methods setting at same time For DMX function please refer to the DMX chart below DMX Chart 0 255 Manual fogging low high output OPERATION After switching on via the On off switch the controllers the LCD display will show READY TO FOG and the unit is now ready for operation DMX Control Mode Operating in a DMX control mode environment gives the user the greatest flexibility when it comes to customizing or creating a show In this mode you will be able to control each individual trait of the fixture and each fixture independently When under DMX mode with DMX cable connected MANUAL IS INVALID If you need to use MANUAL you must unplug the DMX cable Setting the DMX address The DMX mode enables the use of a universal
5. VALVE INPUT WATER OUTPUT 6 LCD controller setting The LCD DISPLAY on the TOP side is for you to control the fog output as follows This machine need several minutes warming up for the first time turning on the machine but once it is with power on it no need warming up for operation after that as it doesn t use any heater systems More control function as below Interval Time Setting To set the interval times press the MENU button to show Interval on the LCD display Now use the UP and DOWN buttons to increase or decrease the interval times between each burst The interval time can be set from 1 900s Duration Time Setting To set the duration times press the MENU button to show Duration on the LCD display Now use the UP and DOWN butions to increase or decrease the duration between each burst The duration time can be set from 1 200s Output Volume Setting To set the output volume press the MENU button to show Output on the LCD display Now use the UP and DOWN buttons to increase or decrease the smoke output each burst The output volume can be set from 0 100 Manual Fogging For manual fog output simply press the MANUAL button and hold until the desired amount of smoke is emitted Constant Burst Operation To set unit for constant burst press the LOCK button To stop the constant burst simply Press the LOCK button again During this operation
6. WATER LOW FOG 1200W USER s MANUAL WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the eguipment in good working condition and to ensure safe operation itis necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty Important The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the equipment Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution Never remove warning or informative labels from the equipment Do not open the equipment and do not modify the equipment Only use the equipment indoors Do not expose to flammable sources or
7. atically pump water into the water tank and the pump will stop working when the water reaches the Max level same level of the output of mist but will automatically pump in water when the water is lower than the Min level required Tanks 2 is a small bottle that can full fill with regular water or if you prefer the fog to rise a little and fog more white you just add 1 fog liquid high quality WATER BASED fog liquid this is very important that this tank is filled by 99 regular clean water 1 fog liquid only This tank lasts very long working time as the main tank is the big one supply most liquid If liquid should get inside the main electronic part disconnect the unit from the mains immediately and consult a technician 3 Ice adding new version of this low fog machine is with a space in the TANK 1 for you to put ice regular ice not dry ice CO to make the effects better You can put a wire mesh in the top of the TANK1 then you can choose to put ice or do not put ice but the machine will work the same 4 After you Plug the power cable to the power socket put 2 tanks with required liquid and ice if necessary you have to cover the tank then turn on the red switch of power on the back gear the machine will work perfectly 5 Gear instruction LCD CONTROLLER PANEL BACK GEAR WITH DMX SOCKETS Bf ety 8 Zoom as below Power Switch DMX IN SOCKET DMX OUT SOCKET FUSE POWER INPUT SOCKET WATER
8. n the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable requirements for DMX operation e The WATER LOW FOG can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output as follows Also remember that DMX cable must be daisy chained and cannot be split CLEANING AND MAINTENANCE DANGER TO LIFE Disconnect from the mains before starting maintenance We recommend a frequent cleaning of the unit Please use a soft lint free and moistened cloth Never use alcohol or solvents Clean the output and the inside of Tank 1 always Fog liquid used for the 1 of Tank 2 we recommend are non hazardous to the environment and can be disposed of via the sewage system There are no user serviceable parts inside this unit except for the fuse Maintenance and service operations are only to be carried out by authorized dealers REPLACING THE FUSE Only replace the fuse with a fuse of same type and rating Before replacing the fuse disconnect from the mains Procedure Step 1 Open the fuse holder on the rear panel with a suitable screwdriver Step 2 Remove the old fuse from the fuse holder Step 3 Install the new fuse in the fuse holder Step 4 Replace the fuse holder in the
9. y of others Incorrect installation or use can Cause serious damage to people and property Before filling the unit disconnects the mains Never fill with hot liquids Only use liquid as our manual suggest as this machine has two tanks with different requirements on each tank Always make sure there is liquid the tank but no more than the MAX LEVEL This machine is different with normal fog or low fog machine as it cannot work with over level liquid if your pump switch is off Operating this smoke machine without any liquid inside will cause damage to the inside part though this machine will stop working and alarm if liquid lower than required level Operate the unit only after you have familiarized yourself with its functions Do not permit operation by persons not qualified for operating the unit and always drain the tank and use the original packaging if the unit is to be transported Operation 1 Unpack the flight case to take out this machine make sure all comes intact 2 Please check the water tanks this machine has 2 tanks as below TANK 1 TANK 2 Tank 1 Is for regular water clean water no chemicals or other fog liquid is allowed to put inside just regular water You can pour inside to tank but never higher than the output of mist at the front or it will pour out from the output through pipe To make this easy you can connect a water hose to the faucet hydro valve and turn on the pump switch then the pump will autom
Download Pdf Manuals
Related Search
Related Contents
Patton electronic 2121 User's Manual 取扱説明書 保証書付 - ご家庭のお客さま/大阪ガス 第5回RECS問題と解答① HEMS/リチウムイオン蓄電池 漁船第十一仁洋丸漁船第十七大和丸衝突事件 Pressure washers – Tools - Tooled Specs Guide pratique pour une meilleure qualité de l`air Copyright © All rights reserved.
Failed to retrieve file