1. Figure 4 6 Delay Time Press number key to input numbers 001 999 Test Time Press number key to input numbers 001 999 Program Unit Press lt gt to choose g dl g l mg dl mg l mmol l U L umol I U ml ug ml ng ml and ug dl Aspirate Volume Press number key to input aspirate volume Program Setup Blank Reagent NUM of Blank 1 Blank Low 0 000000 Blank High 1 000000 Figure 4 7 Blank Press lt gt key to choose Water ion free Reagent or Serum NUM of Blank Press number key to input blank reading times Blank Low Press number key to input low limit value O D Blank High Press number key to input high limit value O D Program Setup Normal Low 35 000000 Normal High 50 000000 Linearity 80 000000 Dilution Factor 1 000000 Figure 4 8 Normal Low Press number key to input low limit value of sample test Normal High Press number key to input high limit value of sample test Linearity Press number key to input linearity value referring to reagent description Dilution Factor Press number key to input dilution ratio The default is 1 Program Setup NUM of STD 1 STD 1 CONC 40 000000 g l Factor 58 70000 Figure 4 9 NUM of STD Press number key to input the number of standards only choose 1 to 8 STD The sequence of standard will automatically change Conc Concentration of standard corresponding to each standard press number key to input Factor This value
2. OD 0 8950 Factor 168 Press Enter to continue Figure 4 25 Press Enter enter the next page the screen will show as Figure4 26 13 Test Control No Figure 4 26 If choose No the instrument will directly do the sample test and the screen will show as Figure 4 29 If choose Yes the instrument will do control test the screen will show as Figure 4 27 001 ALB Control Value 26 g l Press PUSH aspirate Control Figure 4 27 Insert pipette into control then press PUSH button to aspirate control The instrument will test control then display test result as shown in Figure 4 28 ALB No 001 OD 0 8200 Control 36 5g I Press PUSH aspirate Sample Figure 4 28 Press PUSH Aspirate sample 14 Figure 4 29 Press number key to input sample ID the default is No 001 Insert pipette into sample then press PUSH button to aspirate sample The instrument will test sample then display test result as shown in Figure 4 30 CONC 36 5g Press PUSH aspirate Sample Figure 4 30 Press Wash to wash flow cell with distilled water PUSH button to test the next sample ESC back to main menu Attention lf the Program Method is Kinetic the instrument will display the sample reaction curve with test result The screen will show as Figure 4 31 001 ALT No 001 Rate 0 0101 COR 0 990 Conc 24 02 ull Figure 4 31 lf the program Blank is Se
3. button Loose PUSH button when finish aspiration The instrument will display and save movement steps Press Enter back to main menu 4 8 Other Settings Use direction key to choose Other Settings and then press Enter the 25 screen will show as Figure 4 59 Other Settings Heading Setup OD Test Date Format Setup Date amp Time Setup Hospital Setup Figure 4 59 4 8 1 Heading Setup Use A Y to choose Heading Setup and press Enter then input password the screen will show as Figure 4 60 for professionals only Heading Setup SINNOWA BS3000M Figure 4 60 Press number key to input the heading and then press Enter to save and back to previous page 4 8 2 Date Format Setup Use A W to choose Date Format Setup and then press Enter the screen will show as Figure 4 61 Date Format Setup Date Format YY MM DD Figure 4 61 Press lt pb to choose date format YY MM DD DD MM YY or DD MM YY then press Enter to save and back to previous page 26 4 8 3 Date amp Time Setup Use A Y to choose Date Format Setup and then press Enter the screen will show as Figure 4 62 Date amp Time Setup 12 02 06 12 35 20 Figure 4 62 Press number key to input date and time and then press Enter to save and back to previous page 4 8 4 Hospital Setup Use A W t
4. 4 3 3 4 Delete Control All Result ooooooooooonocionononononococnonaconncocncnonononnnncnononannnnononononons 20 4 3 4 Print Rep lt oa A A A a 20 44 System Se UND tasa odas 21 4 41 Temp DISpl y er ioneina rene eraren tirada ideada dida 21 4 4 2 NA A A 22 4 4 3 Printer SQUID nara 22 AAA Language Set p daa 22 4 4 5 ASpirate FOFMAl coito IRA 23 AL AD AUO ZOO ita A A Mat eae a 24 4 6 AD Value Check ada 24 4 1 PUMP Calibre 25 4 8 Other Settings vies i cractenesicsaeainci en ieemriicun iran e e ea e e a iei 25 AR E acabaneenaizcaucpaandacabqaadacthaaeh a nad a a aaa eaaa a 26 4 8 2 Date Format SOU a a E E E a aA 26 4 8 3 Date TIMO Sol init aaa 27 4 8 4 Hospital Setup ao 27 4 8 5 OD TEST n nnee e A EEA E one de a GIO 27 5 Instrument Maintenance sssssssssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnna 28 5 1 Maintenance seee renea Seed ae sk eee deeded aati 28 5 2 LOUD IG SI OOUING ta a a 29 5 3 Fittings Replacement ee eesceeeseseeseeeeeseeeseseeseseeeeaceesaeseseeseesseeesaeeeeeeaeeeeaees 29 9 31 Power SUPPLY Fuse ai NS 29 5 3 2 Peristalsis Pump Tube Replacement ooococccononocnonociononicccnoconocononocncnconcnnnnoncncononos 30 5 3 3 Printing Paper Replacement 0 ee cesceeesceeeseneeeeseeeeseeeeseseseeaceesaeeeaeeeeeeaeees 30 ls A O NN 30 1 Description BS series of Semi Automatic Clinical Chemistry Analyzers is used to measure biochemistry items and a part of immunity items with
5. could be input by operator referring to reagent manual or automatically obtained by calibration Program Setup Control Yes No Control Value 40 00000 g l Cuvette Temp 37 0 C Figure 4 10 Control Press lt gt to choose Yes or No to confirm testing control or not Control Value Input control value referring to control s manual Cuvette Temp Press lt gt to select test temperature 37 C 30 C 25 C and R T room temperature available Program Setup Sure to Add Yes Figure 4 11 Sure to Add Select Yes to save the setting program select No to cancel the setting program 4 1 2 Program Modify Program Modify is for checking and modifying program parameters Choose Program Modify and press Enter the screen will show as Figure 4 12 Program List ALT TP ALB BUN AST GLU Figure 4 12 Use A Y to select the program then press Enter 4 1 3 Program Delete Program Delete is for deleting program Use direction key to choose Program Delete and press Enter the screen will show as Figure 4 13 Program List ALT TP ALB BUN AST GLU Figure 4 13 Use A Y to select the program and press Enter the screen will show as Figure 4 14 Program Setup Sure to Delete Yes No Figure 4 14 Select Yes to confirm deleting select No to cancel deleting 4 1 4 Program
6. data and program 3 Esc To return to the previous menu or main menu 4 Feed For printer to load paper feed paper 5 Wash Wash flow through cell only for SA 20 6 Number keys To input numbers letters and so on 7 Decimal point key To input decimal Remark press PUSH button to clean pipeline and flow cell for avoiding reaction liquid remains Clean the pipeline in the following cases Before starting work everyday After finishing work everyday After testing high concentration sample After being unused for a long time A D value is out of range 4 Instrument Operations Turn on power switch and the screen will display as Figure 4 1 4 2 System Start System test A D convert OK ERROR Filter check OK ERROR Printer online YES NO System initialization OK ERROR Press any key to continue Figure4 1 SINNOWA BS3000M Version 3 8 Biochemistry Analyzer Figure4 2 Press Enter to enter the main menu shown as Figure 4 3 SINNOWA BS3000M Perform Test AD Auto Zero Program Setup AD Value Check Result Process Pump Calibrate System Setup Other Settings Figure 4 3 Use direction key to choose submenu from the main menu Then press Enter to enter the submenu The menu and its individual function is listed in Table 2 Table 2 Menu function No Menu Function 1 Perform Test Do sample test 2 Program Setup Set up parameters of each test item 3 Result Process Result
7. distill water then press PUSH button to aspirate distilled water the instrument will test AD value automatically and then display the AD value as shown in Figure 4 19 Enter next page when the AD value is stable the screen will show as Figure4 20 11 001 Test Blank OD 0 2100 Figure 4 20 If choose No the instrument will use the last blank value and do the standard test directly The screen will show as Figure 4 23 If choose Yes the instrument will do blank test the screen will show as Figure 4 21 001 Test Blank Press PUSH aspirate Blank Figure 4 21 Insert pipette into blank then press PUSH button to aspirate blank The instrument will test blank absorbency then display as shown in Figure 4 22 001 Test Blank OD 0 2100 Press Enter to continue Figure 4 22 Press Enter enter the next page the screen will show as Figure4 23 12 001 Factor Test STD Figure 4 23 If choose No the instrument will use the last factor displayed and do the sample test directly and the screen will show as Figure 4 26 If choose Yes the instrument will do standard test and the screen will show as Figure 4 24 Press PUSH aspirate STD Figure 4 24 Insert pipette into standard then press PUSH button to aspirate standard The instrument will test standard absorbency and calculate factor automatically then display as shown in Figure 4 25 001 CONC 40 gil
8. print review delete and Q C management 4 System Setup Set up temperature filter number cuvette diameter language and print model 5 AD Auto Zero To read blank 6 AD Value Check Inspect the signal value AD value gain and offset of each wavelength 7 Pump Calibrate Calibrate pump movement steps 8 Other Settings For headline time date and OD test 4 1 Program Setup Use direction key to choose Program Setup from main menu and press Enter the screen will show as Figure 4 4 Program Setup Program Add Item Print Program Modify Program Delete Program Print Figure 4 4 4 1 1 Program Add Program Add is for adding new test programs Use direction key to choose Program Add and press Enter All program parameters are shown as Figure 4 5 to 4 11 Attention Please press Enter key to confirm after finishing the setup Program Setup Program Name ALB Program Method End Point Main Filter Sub Filter Figure 4 5 Program Name press number key to input program name e g ALB TP Program Method press lt gt to choose End Point Kinetic Two points and Bichromatic Main Filter nm press lt gt to choose 340 405 492 510 546 578 620 etc Sub Filter nm Press lt gt to choose sub wavelength for Bichromatic method only Program Setup Delay Time 003 sec Test Time 003 sec Program Unit g l Aspirate Volume 0500 ul
9. should be installed by professionals 2 1 Unpacking Unpack outer package and check If the outer package is broken during transportation If the packing contents are complete referring to packing list If you find any problems please contact the local distributor or SINNOWA service department 2 2 Installation Install the instrument on a stable desk Connect power cable with the appointed power supply before connecting check the voltage of the electricity Put waste pipe end at the back of the instrument into waste bottle If voltage drifts more than 10 please connect a stabilizer Switch on the main machine before test The analyzer must be warmed up for 5 minutes at least 3 Instrument Structure and Function 3 1 Structure Print cover Film board Incubator PUSH button Front view ran m F a Socket Fuse Waste tube connector Back view 3 2 Components The main components SCM LCD screen keyboard aspirating probe optical system peristaltic pump and built in printer Flow cell is made of quartz The volume is 32ul The advisable aspiration volume is 300 500ul 3 3 Function of Keyboard and Button PUSH button used for controlling aspirating sample Keyboard composed of 19 film keys the key function is listed in Table 1 Table 1 The key function on the film board No Film key Function 1 Direction key To choose the menus 2 Enter To confirm the inputted
10. 0 minutes The following detergents are recommended 20 NaCLO 95 absolute alcohol and Special detergent If the analyzer stands idle for long time loose the peristaltic pump tube and turn on the analyzer every week 28 5 2 Trouble Shooting 5 2 1 A D value of 0 The lamp is damaged or the voltage is too low The lamp connection is loose contact Filters have loose contact Filters are damaged 5 2 2 AD value out of range There is no distilled water in flow cell Flow cell is dirty There is bubble in flow cell Pipette is leaked or blocked Peristalsis pump hitch Filter is aging or damaged 5 2 3 Wrong test result or bad repetition There is bubble in flow cell Peristalsis pump tube is not installed properly or leaked Aspiration is abnormal Voltage is not stable The sample is haemolytic or the reagent is invalid Attention If there are some problems cannot be resolved please contact SINNOWA distributor and engineer 5 3 Fittings Replacement 5 3 1 Power Supply Fuse Turn off power supply and unplug power supply line On the right underside of the instrument pull out fuse under the socket Replace old fuse with a new one 29 5 3 2 Peristalsis Pump Tube Replacement Open the cover on the instrument side face Pull out the pump tube Replace with the new pump tube 5 3 3 Printing Paper Replacement Open printer cover take away the old printing
11. LT No 001 22 01 04 10 23 17 OD 0 0123 CONC 23U L Normal Low 0 Normal High 40 Exit Figure 4 37 Choose Exit back to previous page Print to print the result 4 3 2 Delete All Result Use A Y to choose Delete All Result and then press Enter the screen will show as Figure 4 38 Delete All Result Figure 4 38 Choose Yes to delete all results No back to previous page 17 4 3 3 Control Manage Use A Y to choose Control Manage and then press Enter the screen will show as Figure 4 39 Control Manage Control Statistic Control Result Delete Control Result Delete Control All Result Figure 4 39 4 3 3 1 Control Statistic Use A Y to choose Control Statistic and then press Enter the screen will show as Figure 4 40 Control Statistic Figure 4 40 Use A Y to choose test program then press Enter the screen will show as Figure 4 41 ALB Control Statistic AV 40 5000 SD 0 8200 CV 0 78 Curve Figure4 41 AV average value of control test SD standard deviation of control test CV control variation rate of control test Curve Print to print QC curve 18 4 3 3 2 Control Result Use A Y to choose Control Result and then press Enter the screen will show as Figure 4 42 Control Result Figure 4 42 Use A Y to choose test program then p
12. Print Program Print is for printing program Use direction key to choose Program Print and then press Enter the screen will show as Figure 4 15 Program List ALT TP ALB BUN AST GLU Figure 4 15 Use A Y to select the program and then press Enter the screen will show as Figure 4 16 4 2 Perform Test SINNOWA BS3000M Project print 001 Test Name ALT Method Kinetic Unit U L Main Filter 340 Sub Filter no Delay Time 030 sec Test Time 030 sec Blank water Blank low 1 Blank High 1 9 Normal Low 0 Normal High 0 Linearity 500 NUM of Blank 1 NUM of Standard 1 CONC of STD 0 U L Factor 1746 Cuvette Temp 37 0 Figure 4 16 Use direction key to choose Perform Test from the main menu and press Enter the screen will show as Figure 4 17 10 Program List TP ALB BUN AST GLU ALT Figure 4 17 Use A Y to select the program and then press Enter If the temperature is up to setting value the screen will show as Figure 4 19 If the temperature isn t up to setting value the screen will show as Figure 4 18 Temp Display Setting Measured Cuvette 37 0 36 5 deg Temp doesn t matched Ignore Wait Figure 4 18 Ignore system enters next page start testing Wait system waiting Exit system back to main menu 001 AD Auto Zero Filter AD 35533 Press PUSH aspirate Water Figure 4 19 Insert pipette into
13. SINNOWA BS 3000M User s manual NANJING SINNOWA MEDICAL SCIENCE amp TECHNOLOGY CO LTD Add Qilin Industrial Park Nanjing China Z P 211135 Tel 86 25 84121523 84125155 Fax 86 25 84127199 http www sinnowa com e mail service Osinnowa com Contents 1 DOS CHIPUION anni anainua aa nern aa anana nan aiana ia rana 1 TU PrinCiples ct wets A A SE 1 1 2 Working Condition iii 1 123 Technical Specificatii nonnai a a E Ss 1 2 Stalin E AA A AE AR AE 2 ZN PACO o LAS 2 2 2 InStallation eai A E E 2 3 Instrument Structure and Function cssseeeeeeeeeeeeeeeeeeneeeeeeeeeeeeeeeeeeeeeees 3 SS A A a e aE ie 3 3 2 COMPONER ns 3 3 3 Function of Keyboard and BuUtton o oooonoooononocconocicnonoccciccnonoccnnonononncnnnnononnoncnnononnnnon 3 4 Instrument Operations asis taa 4 4 1 Program Setup tina e E ener aE etats 5 AVN TROON Ada in en EE la e es 6 4 1 2 Program Modify ccoo 8 4 1 3 Program Delete 32 coi eesti ened anesst Gh nel anes ieee hee ea 9 414 Program PHU oz 2sor het ot cses tando cat aan a T eed aeaten E E 9 4 2 Periorm Tests 1a aor Bl as a tan 10 4 3 Result Process iii niles Aira einai anaes 16 pe HB lt 0 0 2 0 Gere ne e eo e lec ele 17 4 3 2 Delete All Result coororo dosis da Anat i iii 17 4 3 3 A A A 18 4 3 3 1 Control Statistic i eetan o 18 4 3 9 2 Control Rest bo 19 4 3 3 3 Delete Control Result 2 cece ceeseseseneeseeeeesesenesseeeeeseseneseseeeeseaeneneeeeeeeeaeaeeees 19
14. characteristics of high precision good repetition and complete function 1 1 Principle The analyzer is designed on the basis of Lambert Beer Law When a monochromatic light beam shoots through target solute it will be absorbed The solute concentration could be calculated by measuring absorbance The measuring process of the analyzer is represented as following scheme X A J gt lt gt gt D V A gt Light Filter Cuvette flow cell Receiver A D 1 2 Working Condition Power supply AC220V 10 50Hz 2 or AC110V 10 60Hz 2 Fuse 2A Power 150VA Temperature 15 C 30 C Humidity 30 70 Atmospheric pressure 86 0kpa 106 0kpa Keep away from electromagnetism field direct sunlight and ultraviolet radiation Connect power supply to ground well 1 3 Technical Specification Methods End point Two points Multi standard Kinetic Bichromatic and Serum blank ect Test program 204 items which may be modified and deleted Capacity of flow cell 32ul Temperature control 25 C 30 C 37 C 0 2 C room temperature Optical system interferential filters 340 405 492 510 546 578 620nm and two more filters available Light source 6V 10W halogen lamp Photometric range 0 2 5A Display LCD screen Printer built in thermal printer Serial output RS 232 standard Dimension 39cmx37cmx18cm 2 Installations Attention The instrument
15. em Setup is for setting temperature Filter number Cuvette optical path and printer mode Use direction key to choose System Setup then press Enter the screen will show as Figure 4 49 System Setup Temp Display Aspirate Format Filter amp Cuvette Printer Setup Language Setup Figure 4 49 4 4 1 Temp Display Use direction key to choose Temp Display and then press Enter the screen will show as Figure 4 50 Temp Display Setting Measured Cuvette 37 0 37 1 deg Incubator 37 0 37 1 deg Temp Cal Figure 4 50 Setting Input setting temperature 25 C 30 C 37 C RT 21 Measured Display the real time temperature Temp Cal Input password and then input calibration temperature for professionals only 4 4 2 Filter and Cuvette Use direction key to choose Filter and Cuvette and press Enter then input password the screen will show as Figure 4 51 for professionals only Filter amp Cuvette Filters 07 Optical Path 10 igure 4 Filters Setup filter numbers e g 7 pieces of filter in total Optical Path Setup light path e g the light path is 10mm 4 4 3 Printer Setup Use direction key to choose Printer Setup and then press Enter the screen will show as Figure 4 52 Printer Setup Result Print Enable Disable Curve Print Enable Disable Print Mode Normal Concision Figure 4 52 Result Print Print result after testin
16. g automatically or not Curve Print Print reaction curve after testing automatically or not for Kinetic only Print Mode Choose print mode 4 4 4 Language Setup Use direction key to choose Language Setup and then press Enter the screen will show as Figure 4 53 22 Language Setup ENGLISH Figure 4 53 After the choice finished press ENTER to confirm and exit 4 4 5 Aspirate Format Use direction key to choose Aspirate Format and then press Enter the screen will show as Figure 4 54 Aspirate Format Normal Format Express Format Figure 4 54 Use direction key to choose Express Format and then press Enter the screen will show as Figure 4 55 Aspirate Format Air gap 120ul Figure 4 55 Select airgap format machine should work as follows when it is programmed to aspirate 500 micro litter of solution 1 when user present sample at aspiration tube and press aspirate button machine should aspirate 500 micro litter of solution 23 2 machine should wait for 1 sec with no operation this is time when user has to remove sample away from machine 3 after one second peristaltic pump should move to suck 120 micro liter of air 4 after aspiration of air machine can start its normal reading operation 5 after reading machine can throw sample out to waste 4 5 AD Auto Zero Use direction key to choose AD Auto Zero and then press Enter the screen will show as F
17. igure 4 56 AD Auto Zero 33000 100 33540 101 33000 100 35000 102 36000 100 35000 101 34000 100 Figure 4 56 Insert pipette into distilled water then press PUSH button The instrument will adjust automatically The first column is filter wavelength The second column is Gain value The third column is AD value The fourth column is Offset value The normal range of each value shows as table 3 Table 3 Normal range for each value Value Normal range Gain 1 6 A D 26000 38000 Offset 1 350 If the value is out of range check or ask engineer for service 4 6 AD Value Check Use direction key to choose AD Value Check and then press Enter the screen will show as Figure 4 57 24 AD Value Check Filter 340 Gain 3 AD Value 33300 Figure 4 57 Filter Use lt gt to choose filter NO means filter is dark Gain Use A W to choose Gain value AD Value Display real time AD value 4 7 Pump Calibrate Pump Calibrate is for calibrating pump movement steps so when aspiration is not correct Pump Calibrate is necessary Use direction key to choose Pump Calibrate and then press Enter the screen will show as Figure 4 58 Pump Calibrate 0500 ul 01200 Press PUSH aspirate Water Figure 4 58 Operation steps Press number key to input aspirate volume then press Enter Insert pipette into water press PUSH
18. o choose Hospital Setup and press Enter then input password the screen will show as Figure 4 63 for professionals only Hospital Setup MALIYA Hospital Figure 4 63 Press number key to input the heading and then press Enter to save and back to previous page 4 8 5 OD Test OD Test is for testing real time absorbency of sample directly Use A Y to choose OD Test and then press Enter show as Figure 4 64 Filter AD Value OD Figure 4 64 Operation steps Press lt gt to choose the filter wave length and then press Enter to confirm Insert pipette into distill water and then press PUSH button to aspirate water The instrument will test the water blank AD value Press Enter until the AD value is stable Insert pipette into sample then press PUSH the instrument will test and display real time sample absorbency Press ESC back to previous page 5 Instrument Maintenance 5 1 Maintenance There are two kinds of maintenance daily maintenance and weekly maintenance 5 1 1 Daily Maintenance Clean the flow cell with distilled water before and after the instrument works Insert the pipette into distilled water press Wash 5 1 2 Weekly Maintenance Clean the flow cell with detergent Insert the pipette into detergent press Wash Attention Detergent should remain in flow cell for about 5 1
19. paper Load the new printing paper into the paper slot Put the paper to the form feed Press Feed Attention If there are some problems cannot be resolved please contact SINNOWA distributor and engineer 6 Storage Packed instruments should be placed in the well ventilated room avoiding hard by poisonous harmful and corrosive substances End 30
20. ress Enter the screen will show as Figure 4 43 Control Result 24 03 07 12 21 15 25 03 07 08 21 59 26 03 07 15 21 21 27 03 07 09 21 38 Figure 4 43 Use A Y to choose control result then press Enter the screen will show as Figure 4 44 ALT No 001 22 01 04 10 23 17 OD 0 0123 Conc 23U L Exit Figure 4 44 Choose Exit back to previous page Print to print the result 4 3 3 3 Delete Control Result Use A W to choose Delete Control Result the screen will show as Figure 4 45 19 Delete Control Result ALT TP ALB BUN AST GLU Figure 4 45 Use A Y to choose control program then press Enter the screen will show as Figure 4 46 Delete All Result Figure 4 46 Choose Yes to delete control result No back to previous page 4 3 3 4 Delete Control All Result Use A W to choose Delete Control All Result and then press Enter the screen will show as figure 4 47 Delete All Result Figure 4 47 Choose Yes to delete control all result No back to previous page 4 3 4 Print Report Use A Y to choose Print Report and then press Enter the screen will show as Figure 4 48 20 Print Report No 001 07 03 12 Figure 4 48 Input sample ID the default is 001 and date then press Enter to print the report 4 4 System Setup Syst
21. rum the sample test has 2 steps After testing AD blank standard and control and then screen will show as Figure 4 32 Press PUSH aspirate Serum Figure 4 32 15 Firstly insert pipette into serum blank then press PUSH button The instrument will test OD1 absorbency of serum blank then display as shown in Figure 4 33 Press PUSH aspirate Sample Figure 4 33 Secondly Insert pipette into sample then press PUSH button The instrument will test OD2 absorbency of sample calculate result then display as shown in Figure 4 34 001 TBIL No 001 OD1 0 1200 OD2 1 1200 CONC 45 1 g l Press PUSH aspirate Serum Figure 4 34 Press ESC to return press PUSH to test next sample 4 3 Result Process The instrument can store 1000 test results and update with new test results automatically Use direction key to choose Result Process then press Enter the screen will show as Figure 4 35 Result Process Result List Delete All Result Control Manage Print Report Figure 4 35 16 4 3 1 Result List Result List is for browsing and printing test results Use A W to choose Result List and then press Enter the screen will show as Figure 4 36 Result List 0001 22 01 04 10 0002 22 01 04 10 0003 23 01 04 09 Figure 4 36 Use A Y to choose result number and then press Enter the screen will show as Figure 4 37 A