1. mode This mode will maintain a set temperature default 10 C all the time Use up or down arrow button to change the set point Re connect the thermostat ribbon cable and clip the two halves together Carefully unplug the ribbon connector which is plugged in to the front half of the thermostat Place the thermostat front half somewhere safe Terminate the thermostat as shown in the diagrams below Screw the thermostat back plate on to the back box Reset to Factory setting With thermostat turned off press and hold button M and Q until you can see RESET on LCD Temporary temperature override Outen Using up down arrow buttons you can adjust the current set temperature O ride Use button to accept and you will see override on LCD and thermostat will maintain the new set temperature until the next programmed event comfort level To cancel the override setting just press and hold button for 3 seconds until override disappear Floor Sensor View floor temperature If thermostat is set to AF model and set to show air temperature only press and hold up arrow button for 3 seconds floor 3500 WATTS temperature will display and it will automatically revert back to air temperature after 5 seconds MAX 16 AMP FEED 220VAC 4 10 This product should be installed by a qualified electrician
2. saving temperature Set to the time you leave home and the temperature you wish your home to maintain while you are away at work perhaps Above are default program schedules to make changes follow easy steps as below Programming your thermostat or setting these daily events is no more complicated than setting the clock The same buttons are used in the same sequence using the button 2 button M to advance to the next step and the up or down buttons to make changes The LCD shows only relevant information flashing for the event being adjusted thus reducing possible errors that may be caused by having confusing information displayed on the LCD To enter the program mode Make sure your thermostat is turned on when you want to set the program schedules Use button P to turn on off the thermostat Make sure your thermostat is set to Auto mode use button M toselect Auto or manual mode Press and hold button P for 5 seconds The display will change to show PROG together with Day for example Mon Monday flashing Using the up or down buttons adjust the day to the day you wish to start programming or to the day you wish to edit an existing event or program Press and hold the up button for 3 seconds to select all days of the week to cancel selecting all days of the week press and hold up button for 3 seconds again Press button P to accept the day and advance to the next step the LCD will show programme mae together with time area flashin
3. D program time delay before reverting back to standard display 5s 10s 15s_ 20s default 25s 30s This gives option to choose to show air temperature floor temperature or to show both floo amp air in interval A to show air temperature only F to show floor temperature only A F to show both in 5 second intervals TR Temperature readout AF model only MAXFT set maximum floor temperature id AF model 40 C by default setting range 20 C 40 C This is to protect the floor surface BL backlight turning on time setting TF temperature format CLOCK FP Frost protection SC setpoint configuration MD model display AL Auto lock Remarks This is to set the backlight turning on time User can also set the backlight always on or off This alows users to select between C or F 12 24 HOUR clock system selection This is to avoid room temperature goes below 5 C This allows user to select 2 kinds of default setpoints To display model A AF F on LCD To lock the buttons automatically after 20 minutes of no operation on buttons 30 seconds default On always on OFF always off C or F 24 default 12 hour or 24 hour clock system ON activated OFF deactivated 4 means 4 independent setpoints 2 means setpoint 1 is the same to setpoint 3 setpoint 2 is the same to setpoint 4 ON activated OFF deactivated ON activated OFF deactivated Not all menus are visi
4. TR3100 Thermostat Instructions ver 1 4 Buttons and LCD symbols Buttons Short Press Press and Hold for 3 seconds Power button Turning on off thermostat with thermostat turned off you will only see temperatrue display on LCD With thermostat turned on you will see more detailed information on LCD such as time day mode etc Setting the schedules programmes while thermostat is turned on Setting the menus with thermostat turned off M button Mode selection Auto mode manual mode Confirmation button accept the set values Set the time and week days Up arrow button increase the set value Show floor temperature in AF model Down arrow button decrease the set value Bring up vacation mode Description Symbols Description The buttons are locked Frost protection activated Heating is turned on Set temperature The difference between set temperature and room temperature more bars means more difference Programmes number Manual mode Room temperature Optional Remote Control Auto mode Floor temperature Comfort temperature AF F A Temporary temperature override Economy temperature Model Vacation mode LO Room or floor temperature is below 0 C meaning that floor sensor is short circuit or broken HI Room or floor temperature is greater than 50 C Configuration Menu To enter into menu settings follow below 2 steps Step 1 Turn the thermostat off by pressin
5. ble in certain models For example if you set the thermostat to A or F model menu 6 and menu 7 will not be visable See overleaf for further setting up information TR3100 Thermostat Instructions ver 1 4 Setting the clock and day of the week 7 This thermostat is fitted with a real time clock It is essential that the clock time and day are set accurately if you require your programmed events to start on time Follow below steps 1 Press and hold button Q for 3 seconds and you will see the time flashing Use the up down arrow button to change the time 2 Press again to accept and proceed to day of the week setting Now you will see day flashing use the up down arrow button to change the day of the week 3 Now press Q again to store and exit Save money by setting program schedules This thermostat is an individual 7 day programmalbe For each day of the week you are able to have 4 timed set temperature schedules or programmed events For clarity these events are conveniently named 1 2 3 and 4 o I l l at ei 22 C Set to the time you would like to wake to and the temperature you want during the morning until you left for the day LEAVE o Lit 09 30 me 37 RETURN L it 16 30 22 C Set to the time you return home at end of the day and the temperature you want during evening until bed time SLEEP Rs 22 30 16 C Set to the time you sleep and the temperature you want overnight usually a comfortable and energy
6. g Using the up or down buttons adjust the time you wish the programme 1 event to commence for the currently selected day Press button P to accept the time and advance to the next step the LCD will show a temperature value flashing Using the up or down buttons set the desired heating temperature to be maintained for the programme 1 event Press button P again to accept the temperature setting and advance to the next step the LCD will show programme NAS together with time area flashing signifying the second daily event is now being programmed Using the up or down buttons adjust the time you wish the programme 2 event to commence as described previously Continue to press button P to accept the time and advance to the next step the LCD will show a temperature value flashing Using the up or down buttons set the desired heating temperature to be maintained for the programme 2 event Repeat step 6 7 8 9 to set program 3 fala and program 4 KL events Lock the buttons Installation and Wiring To lock the buttons press and hold the up amp down arrow buttons Carefully separate the front half of the thermostat from the back plate by placing a small for 3 seconds you will see a lock symbol Tounlock flat head terminal driver into the slots on the bottom face of the thermostat repeat the steps above and the lock symbol will disappear Vacation mode Press and hold down arrow button until you see D on LCD Use same procedure to exit this
7. g P button Step 2 Press and hold button M for 3 seconds until you see Menu 01 on LCD Then by each press of button M will cycle the thermostat through available menus as below Use up or down arrow button to change the setting for each menu press button M to accept and proceed to the next menu To store the menu settings and exit press button P Features description Features Explanation Adjustment press up or down button to adjust This thermostat is a combination model allowing you to choose between 3 different models A AF and F model A model air only with built in sensor AF model air amp floo r with both built in and remote sensor F model floor only with remote sensor Model model selection The numbers of degree difference before switching The default is 1 C which means the thermostat will switch the heating on 0 5 C below the set temperature and will turn it off 0 5 C above the set temperature With a 2 C differential the heating will switch on 1 C below the set temperature and will switch off 1 C above the set temperature Sd switching differential 1 1 degree default 2 2 degrees ATC air temp calibrate This is to calibrate air temperature if required 1 decrease 1 degree 1 increase 1 degree FTC floor temp calibrate AF F model only This is to calibrate floor temperature if required 1 decrease 1 degree 1 increase 1 degree This gives more time for user to set the programmes PT