1. 4 00 Maintenance and storage 4 01 Cleaning Clean the GH3 with a damp cloth and mild handwash detergent Do not use strong acids bases or alcohol to clean the GH3 Never clean GH3 in an autoclave 4 02 Storage See 3 00 For long therm storage disconnect the battery plugs and the plug from the battery at the charging PCB 4 03 How to prevent avoid corrosion When the GH3 is mainly used in an corrosive environment e g swimming pool the hoist must be ordered with a special corrosion preventive surface treatment 4 04 The owner s daily maintenance duty Check the lifting sling for wear and damage before use Do not use the lifting sling if it is damaged or defective Do not use the GH3 if the lifting strap is damaged or defective Contact your supplier and order a new lifting sling or a replacement of the lifting strap Replacement of the lifting strap must only be performed by the Guldmann Service Team or by a qualified technician in accordance with Guldmann s instructions 32 Guldmann GB US 09 2012 550216 6 01 Guldmann GB US 09 2012 550216 6 01 4 05 Disposal of the GH3 including batteries Local and national regulations on environmentally correct recycling must be observed Batteries type NiMH must always be delivered to an approved recycling point 5 00 Service and lifetime 5 01 Lifetime The GH3 has an expected lifetime of 15 years on the condition of coorect use and correct service
2. Configuration of supplementary modules takes place from the GH3 hand control Setting the language Next service Scale Statistics Language English 2008 04 22 Press any key on the GH3 hand control to activate the hoist When the hoist is activated the display on the hand control is switched on and the Guldmann logo G appears Select Menu using the function key located immediately below the display and then select until the Setup menu appears in the display Select Setup and then gt until the Language menu appears in the display Select Change until the preferred language appears in the display and confirm the selection by pressing OK Then return to Setup Select gt to return to the start menu 20 Guldmann GB US 09 2012 550216 6 01 Guldmann GB US 09 2012 550216 6 01 2 06 Setting the units kg Ibs Scale module Scale Statistics Next service Setup Scale ees F L B Press any key on the hand control to activate the hoist When the lifting module is activated the display on the hand control is Switched on and the Guldmann logo G appears Select Menu using the function key located below the display Then select until the Setup menu appears in the display Select Setup and then until the Units menu appears in the display Select Change to switch between the units kg and Ibs and confir
3. Disposal of the GH3 including batteries 00 33 5 00 sce can Service and lifetime 2 0 00sec x x e e 33 5 01 tes MW up TT 33 5 02 snis Safety service inspections 000 ccc eee ees 33 DOI x jesse RR ep TIFOUDISS MOOR Oasa sor c E run x ve N and epa Exe e ve ce en molten e nude 34 Guldmann GB US 09 2012 550216 6 01 Guldmann GB US 09 2012 550216 6 01 PE iss Certificates rc 9 5 cesa ke s K haee n R RRR RR RR RRR CR RU RR a 36 8 00 xs s Technical specifications lt a s X 29 K 0 K 9 0 R R 9 9 R R 9 K eee 36 9 00 ee cece ae EC Declaration of conformity 000 cee eee eee eee 39 or USA and countries outside the EU ee 40 1 00 Purpose and use 1 01 Manufacturer V Guldmann A S Graham Bells Vej 21 23A DK 8200 Arhus N Tel 45 8741 3100 Fax 45 8741 3131 www guldmann com 1 02 Purpose The GH3 is a ceiling mounted hoist which covers the need for lifting or moving a person in hospitals nursing homes institutions swimming pools riding schools and private homes Conditions for use The use of the GH3 is subject to the following The GH3 should only be used by trained personnel The maximum nominal load 200 kg 440 Ibs 250 kg 550 Ibs 300 kg 660 Ibs 350 kg 770 Ibs respectively must not be exceeded The instruction offered by Guldmann to all customer groups in connection with the purchase of a ceiling mounted hoist has been received The helper pays at
4. while lifting the strap on hoist A to perform the swing transfer The transfer has been completed when there is no load on the lifting strap on hoist B Disconnect the lifting strap on hoist B from the lifting hanger and raise the strap on hoist B out of the way Move the lifting hanger from hoist A to operating height and the doorway transfer is complete A B GH3 with horizontal drive motor The GH3 with horizontal drive motor can operate in the rail system Be aware that the drive motor takes time to both accelerate and brake the hoist It is possible to position the hoist with horizontal driving motor with a high degree of accuracy by a brief activation of the hand control The GH3 with horizontal drive motor runs on its own power and it should not be pulled through the rail system 2 00 GH3 with horizontal drive motor and infrared remote IR control The GH3 has an integrated IR receiver which is controlled by the IR remote control The hand control should be left attached to the hoist This means that the hoist can always be operated in the the event that the IR remote control is mislaid or the battery is uncharged Description of functions Information panel on the GH3 bottom surface Lamp indicator Ner 13534 Guldmann GB US 09 2012 550216 6 01 Guldmann GB
5. Covers Impact resistant UL 94 V 0 flame retardant recyclable plastic Digital Scale Specifications Non medical Optional for GH3 Capacity dence EE A TRE olin beet ee HET RH REER 0 SWL ACCULACY ato an aue RRR a ee E E E 0 1 at max load Display resolution Q cece cied aR a Ry R eee eee eee 0 1 kg 0 22 Ibs Repeatability soso ed ated K eene lt 0 1 kg at 0 200 kg 0 440 Ibs lt 0 2 kg at 0 350 kg 0 770 Ibs Minimum Weight 52 p pier di cae eh aed a dees 5 kg 11 Ibs Display types isa ad dente Sea den Chae RAAT eps LCD in Hand Control 37 Dimensions D TTT 580 mm 22 8 inch Ba RRR ba RTE aoe ae Saat R Saat T 9 345 mm 13 6 inch cnm 156 mm 6 1 inch D nare em arto En es R R abra ERR EO P sea RUE 0 184 mm 7 2 inch ule rm 82 mm 3 2 inch EUI PA petod ace a wel d nde dre Qa oS ed 445 mm 17 5 inch carr 2500 mm 98 4 inch Depth Of hoiSE sic sag tele A cw ma em eem e mre 205 mm 8 1 inch Safety Emergency Stop ie RR rp eese x etre Yes mechanical and electrical Emergency lowering device 2 ce eere m rmm Yes ontrol or Ming Strap sarreron rrt eur Vier ql Yes Cut off angle c cece ems 45 along the rail 10 across the rail 38 Guldmann GB US 09 2012 550216 6 01 Guldmann GB US 09 2012 550216 6 01 9 00 Electronics OMOT reaa trek agere Automatic when used Soft start stop Overload protection ortis e R ede E REPE eee ea Automatic Low Batter
6. a taylordolman GB US GH3 GH3 Ceiling Hoist Vers 6 01 Guldmann Guldmann GB US 09 2012 550216 6 01 GHS Lifti ules version type nenclature Guldmann Product Load in Number Number Number of Scale CLM Service User hoist type line Kg of lifting of lifting horizontal module module module interface straps motors drive motors SIUE OSEN SOC ONES END GCSE SEED Ed GH3 200 1 1 1 250 1 1 1 250 1 1 1 None 0 None 0 None 0 Hand Scale 1 CLM 1 Service 1 control 0 300 1 2 2 Config 2 Config 2 IR 14 350 1 2 2 Twin 250 2 2 0 500 2 2 0 GH3 X Y Z Z zZ Q Q Q Q g GH3 GH3 Ceiling Hoist Item nos 552xxx 100 Purpose and sSe 2 un eem ERG ERU ERR RUE S e ERROR i 6 1 01 mn Manufacturer uses ta ne RR gen men rea ea RUE Ra 6 1 02 cantus PURPOSE pcc 6 VOB ks Important Precautions dR NTN ka korea Eee mA wants 6 1 04 s Load limits on GH9 system ee 22e e pedore n px eee anaes 7 1 055 os iot Unpacking and Preparation liliis 7 1 06 ns Placing a new GH3 Hoist in an existing rail system 7 WOT 55 tmm Power SUDDly 255 2 mde eh one o retos Pe yid ce eae ee ea d 8 TOS xs Installation of the lifting hanger before use nannan 9 1 09 tS LIMING SING EET O 10 T 10 E E Dons eem ER 12 1 11 nus Using swing Kit il doOrWay xim mr rette eee 13 1 12 ete GHS3 with horizontal drive motor eese seiten araneon eee ee
7. control will automatically revert to the screensaver after approx 8 min Accessories for the CLM module GH3 The CLM module includes an extended management menu which can be operated via a PDA Net Book with Guldmann CLM software installed The PDA Net Book is connected to the GH3 hand control via a mini USB plug located in the base of the hand control see section 2 04 Contact supplier or the Guldmann Service Team for further information about CLM accessories Guldmann GB US 09 2012 550216 6 01 25 2 08 Service module GH3 with service module The GH3 with Service module option saves all of the information about time and indication of next safety service inspection The GH3 with Service module specifies the date of the next safety service inspection Operation Next service 2008 04 22 Press any key on the hand control to activate the hoist When the lifting module is activated a display on the hand control is switched on and the Guldmann logo G appears Select Menu using the function key located immediately below the display Then select until the Next service menu item appears in the display Read off the date of the next safety service inspection Year Month Date 26 Guldmann GB US 09 2012 550216 6 01 Guldmann GB US 09 2012 550216 6 01 Pop Up s for Service module supplementary module There are two different Pop Up s bri
8. hanger Fig 2 to 5 Hold the lifting hanger in the right hand and press the yellow button using the thumb Fig 2 Insert the swing adapter in the slot on the lifting hanger top cover with the open side facing down Fig 3a 3b and release the yellow button Rotate the swing adapter to a vertical position Fig 4 Check that the yellow button has returned to its locked position by checking that it is flush with the cover of the lifting hanger and that the swing adapter can rotate freely Install the strap attachment to the swing adapter by sliding the open side of the strap attachment over the flat area of the swing adapter Fig 5 Rotate the strap attachment and ensure that it moves up on the circular portion of the swing adapter Fig 6 Guldmann GB US 09 2012 550216 6 01 Guldmann GB US 09 2012 550216 6 01 Using swing kit in doorway Bring the two hoist as close together as possible Adjust the height of the lifting hanger on hoist B so that the transfer can be done without the user touching the floor during the transfer from one hoist to another Take the free lifting strap from hoist A and secure it to the swing adapter on the lifting hanger see 1 10 figures 5 and 6 In order to lower the free lifting strap on hoist A a slight pull must be applied to the strap Lower the lifting hanger using hoist B
9. in the lifting hanger s hooks When pressing the up button to lift the user check again that all the straps remain correctly placed in the lifting hanger s hooks fig 1a and fig 1b Guldmann GB US 09 2012 550216 6 01 Guldmann GB US 09 2012 550216 6 01 Lifting to and from a seated position When lifting a user from e g a wheelchair move the GH3 towards the person to be lifted The lifting hanger should be at the same height as the user s chest and should not be moved further in over the user than to approximately mid thigh position Place the lifting hanger parallel to the user s shoulders Place the lifting sling behind the user s back between the back of the chair and the user s back The centre band of the lifting sling should follow the user s spine As for the slings type Active the strap showing the size of the sling should be opposite the spine Lead the leg straps along the outer sides of the user s shins and beneath the thighs between the hollow of the knees and the hip joints Cross the leg straps in front of the user All four lifting straps are now ready to be attached The lifting sling can now be mounted on the lifting hanger Lifting to and from lying position in bed Bring the lifting hanger over the centre of the person to be lifted Place the lifting hanger parallel to the user s shoulders Turn the user onto his or her side The Basic High sling should be placed so that it
10. inspections see section 5 02 Replacement of components Replacement of batteries PCBs and lifting straps must be performed by a qualified service technician or the Guldmann Service Team 5 02 Safety service inspections In accordance with international standard EN ISO 10535 Hoist for the transfer of disabled persons Requirements and test methods an inspection should be performed on the hoist at least once a year Guldmann recommends that regular safety service inspection is performed at least once a year with regard to the pattern of usage Inspection of the GH3 must be performed by a qualified service technician or the Guldmann Service Team In connection with the purchase of the GH3 Guldmann may offer a service agreement for this inspection NB The GH3 with service module may only be serviced by the Guldmann Service Team or by a qualified service technician with access to the PDA Net Book with Guldmann software During the safety service inspection a report must be prepared on what was checked and replaced Parts that are worn or defective must be replaced with new parts from Guldmann Spare parts drawings and documentation can be obtained from the manufacturer or supplier Documentation checklist regarding safety service inspection can be obtained from the manufacturer or supplier 33 5 03 hon gt Troubleshooting The GH3 does not respond to the hand control s keys Check the emergency stop is not activ
11. to the first position Safety This product is mechanically protected against derailing and jamming Combi lock manual and electric The Combi lock is used when a single track rail system is to be linked up to a room covering rail system or when two room covering rail systems need linking The Combi lock ensures that the two systems are locked together in situations such as transfer from a single track rail system in a bedroom to a room covering system in a bathroom The Combi lock is available as an electric or a manual model It is activated by either pressing the switch or pulling on the cord Safety This product is mechanically protected against derailing and jamming Infrared remote control Turntable and Combi locks can be supplied with receivers for IR remote control Batteries NiMH Battery 24V 2800mAh Guldmann type number 550574 Transformer Transformer Class 1 Guldmann item number 550200 Transformer Class 2 Guldmann item number 550269 EU 550268 US CAN 31 3 00 Transport and storage Guldmann recommends that the GH3 is always transported and stored in the original packaging Key to symbols on the GH3 packaging 1 0 Yt 10 gt 40 C 30 70 700 1060hPa 14 gt 104 F The GH3 should be stored at Temperatures between 10 and 40 C 14 and 104 F A relative air humidity of between 30 and 70 An air pressure of between 700 and 1060 hPa This side up
12. use again Please contact your supplier Emergency and lowering strap The red strap has the following functions One pull Emergency stop is activated Constant pull 2 steps Emergency lowering is activated It will work with following load GH3 up to 250 kg 550 Ibs from approx load 80 kg 176 Ibs GH3 from 300 kg 660 Ibs from approx load 120 kg 264 Ibs 2 oa Emergency stop If the GH3 does not stop react to the hand control when the GH3 is in use pull the red strap and all lifting lowering horizontal driving functions except emergency lowering are deactivated When the emergency stop is activated the hoist will not function The green lamp is switched off Reset emergency stop Reset the emergency stop by pressing the yellow button on the bottom of the hoist The yellow button that appears when the emer gency stop is pulled must be pressed manually before the GH3 is ready for use After deactivating the emergency stop activate the hand control twice 28 Guldmann GB US 09 2012 550216 6 01 Guldmann GB US 09 2012 550216 6 01 Remove the side covers Then release the hoist s motor by turning Emergency lowering function electric If the GH3 fails the electrical emergency lowering function is used to lower the user safely The emergency lowering function is operated by a constant pull on the red strap that is used for the emergency stop Electric e
13. 14 1 19 T GH3 with horizontal drive motor and infrared remote IR control 14 2 00 2s Description of functions x x x e x e x x K eene 14 201 aeeie lT nomin oe et ser reitera iud anm vedi egi SEHE ESSE TR Rua Hs 15 2 02 ub Indicator lamps and audio signals liliis else 15 2 09 ise Op ration 5s eoe eb wp Suh ee Gee dg ex 16 204 eiu Supplementary modules GH3 elles 18 T Menu structure Supplementary modules GH3 18 2 05 doe na Configuration of supplementary modules GH3 04 20 2 00 cese Scale module GH3 with integrated scale module 21 2 07 s ies CLM module GH3 with statistical function for management use 24 2 08 Lm ous Service module GH3 with service module naaaa aunan nana 26 2 09 5 coss Safety TUACHONS 4 logie ete a eod ae ha meon Bade RC RR iode 28 210 s ces Charging Connectloh s aaa aa tubes dese d Se eee dE eR wand ox 30 2 41 es ACCESSOTIGS cce tek aha E PA ee actua d podre RO re C OX Dp ee 30 3 00 e Transport and storage s x x x e x eere 32 4 00 Maintenance and storage ss x x e x x leere 32 4 01 5 Anes Cleaning isane aki Lace Pek ibe KB R AT AE wore EAE DID A ead 32 4 02 1 5 done Storage c erT suere pU REUS es ud petit ees 32 4 03 How to prevent avoid corrosion assesses er e K R K e R K K eese 32 4 04 The owner s daily maintenance duW cee eee eee 32 4 05
14. 2 horizontal drive motors 2 lifting motors 1 lifting strap Safe Working Load SWL 350 kg Ceiling hoist type GH3 36 Guldmann GB US 09 2012 550216 6 01 Guldmann GB US 09 2012 550216 6 01 Functions Lifting capacity SWL 200 kg 440 Ibs 250 kg 550 Ibs 300 kg 660 Ibs 350 kg 770 Ibs OD6ratiOrn saas coher epit p oe dr Sead E olea Hand control IR Soutrid Ievel i nme teer ed E een eee 52 dB A Horizontal Speed eee mem tote 18 m min 709 inch min GH3 GH3 Lifting speed 85 kg 187 Ibs load 40 mm sec 1 6 inch sec 60 mm sec 2 4 inch sec 150 kg 330 Ibs load 40 mm sec 1 6 inch sec 60 mm sec 2 4 inch sec Max capacity load SWL 40 mm sec 1 6 inch sec 55 mm sec 2 2 inch sec Max 5 kg 11 Ibs load 100 mm sec 3 9 inch sec 100 mm sec 3 9 inch sec Weight and materials E 200 kg 440 Ibs 250 kg 550 Ibs Owi weights ceste TR N E T E re som eie m um RN Sots 9 6 kg 21 1 Ibs with horizontal drive motor llli lessen 10 5 kg 23 1 Ibs with scale module and horizontal drive motor 11 1 kg 24 5 Ibs SWIE desto sand En PETI DR ose 300 kg 660 Ibs 350 kg 770 Ibs Own weight 2e ni TR etr R UR RUE Madu K ALE eon 14 2 kg 31 Ibs with horizontal drive MOtoR ission rudine dagie eee eee 15 9 kg 35 Ibs with scale module and horizontal drive motor 0000 R eee eee 17 3 kg 38 Ibs
15. A Users guide Before using the product read the entire operation manual including warranty B WARRANTY Guldmann warrants its equipment is free from material defects under normal use and will perform substantially in accordance with the specifications set forth in documentation provided with the equipment This express warranty shall be in effect for one year from the date of original purchase and installation the Warranty Period If a valid claim is made during the Warranty Period for malfunction or equipment defect Guldmann will repair or replace the equipment at no additional cost to you Guldmann retains sole discretion as to whether the equipment will be repaired or repla ced This warranty shall be null and void if the equipment is operated and main tained in any manner inconsistent with its intended use or the instructions provided with the product Further in order for the warranty to remain in effect for the full Warranty Period all service to the equipment must be provided by a Guldmann designated technician Any parts or components repaired or replaced by a Guldmann designated technician will be guaranteed for the remainder of the Warranty Period The warranty does not cover any part of the equipment which has been sub ject to damage or abuse by the user or others The warranty does not cover any part of the equipment which has been altered or changed in any way by the user or others Guldmann does not warrant
16. P20 www guldmann com Guldmann Barcode 128C Transformer Class 2 Use within US CAN Transformer Class 2 Use within EU Type DK 14001 Input 100 115V AC 50 60 Hz 1A B A Output 33V AC 2 5A Prod date yyyy mm dd Serial no 00x WS C IP20 www guldmann com Guldmann Barcode 128C Type DK 13992 Input 230V AC 50 60 Hz 0 5A B A X Output 33V AC 2 5A Prod date yyyy mm dd Serial no xxx C IP20 www guldmann com Guldmann EZAB Lifting hanger xxx kg xxx Ibs Part no 0000 Edition XXX Prod date yyyy mm dd Serial no XXXXX Barcode 128C V Guldmann A S www guldmann com 35 Hand control Part no XXXxxx Edition xxx Date XXXX XX XX IP44 g 7 00 Certificates UL 60601 1 UL No 305250 EN ISO10535 HMI No 08 49A 09 14A 09 15A 8 00 Technical specifications dules version type nomenclature Guldmann Product Load in Number Number Number of Scale M Service User hoist type line kg of lifting of lifting horizontal module module module interface straps motors drive motors ESEE A GH3 200 1 1 1 250 1 1 1 250 1 1 1 None 0 None 0 None 0 Hand Scale 1 CLM 1 Service 1 control 0 300 1 2 2 Config 2 Config 2 IR 1 350 1 2 2 Twin 250 2 2 0 500 2 2 0 GH3 X Y zZ Z Z Q Q Q Q Example GH3 350 122 1000 GH3 350 1 2 2 1 0 0 0 Hand control w o Service module w o CLM module Scale module
17. US 09 2012 550216 6 01 2 01 Ex lt lt Pictograms Emergency stop V Emergency lowering function M Reset emergency stop v Direction of travel horizontal drive motor denoted by grey arrow 2 02 Indicator lamps and audio signals EN Eg E A GH3 EA E A LB Ea S e zil9lsls 2ld o 3 TETE 32 lalg s a a TEE 2 BS ad by All OK Green X X X X x No charging Yellow 3 x Beep after 60 sec XIX X X x after 15 sec Low battery Yellow X X X x x Fault on Yellow Beeps at button activation x x hoist Battery Yellow Beeps at button activation x x x critical low that is not permitted Over load Yellow Beeps at button activation x x Service date Yellow Beeps at button activation X X X x x exceeded more than 60 days 2 03 N M lt k NA Operation Hand control The GH3 is switched on automatically when a button on the hand control is pressed The GH3 is switched off automatically after approx 8 minutes without activation GH3 Lift Lower GH3 with horizontal drive motor Lift Lower Movement in the direction of the arrow on the GH3 information panel section 2 00 Movement in the direction opposite to the arrow on the GH3 information panel section 2 00 GH3 Lift Lower Function selection button section 2 05 supplementary modules Function selection button section 2 05 supplementary modules PDA int
18. ated Check the hoist has power supply Check the transformer is switched on and connected to the rail system Contact the Guldmann Service Team 6 00 a 7 M b Classification CE marking Medical equipment with respect to electrical shock fire and mechanical hazards only In accordance with UL 60601 1 CAN CSA c 22 2 No 601 1 Type B in accordance with UL EN 60601 1 Read the manual before use Must not be disposed of as standard household waste must be recycled Class equipment Permanent installation with protective ground Class II equipment Non permanent installation without protective ground The equipment is not suitable for use in the presence of flammable mixtures Degree of protection against harmfull ingress of liquids water Hoist IP20 Hand control IP44 Remote control IP20 Transformer IP20 34 Guldmann GB US 09 2012 550216 6 01 Guldmann GB US 09 2012 550216 6 01 Examples of serial number label Lifting module fa GH32501100000 max 250 kg 550 Ibs Part no J0000X Lo a Prod date yyyy mm dd WU C A AX Serial no xxxxx kioii 33V AC 2 5 A IP20 CONTINUOUS OPERATION INTERNALLY POWERED WITH SHORT TIME LOADING EQUIPMENT 24V DC Guldmann Barcode 128C keane Transformer Class 1 Type DK 13991 Input 100 115V AC 50 60 Hz 1A A X Input 230V AC 50 60 Hz 0 5A Output 33V AC 2 5A 2 Prod date yyyy mm dd NS C Serial no x xxx I
19. ction has been activated in the GH3 the hoist MUST be serviced by a qualified technician or by the Guldmann Service Team 2 10 2 11 Charging connection The GH3 is automatically charged troughout in straight rails This guarantees the hoist functionality and maintains the batteries to ensure a long lifetime The indicator lamp on the bottom of the hoist turns yellow if the charge status becomes low or if there is a complete interruption to the charging function The GH3 then has a limited number of lifts available at a time and must be re charged The transformer must be connected and switched on before charging can take place A green indicator lamp on the transformer indicates that it is connected and switched on Accessories Guldmann ABC slings and lifting hangers Obtain a brochure from your distributor manufacturer or at www guldmann com Extension strap The extension strap is used where the distance between the lower part of the rails and the floor exceeds 3 5 m 11 7 The extension strap is available as an accessory 30 Guldmann GB US 09 2012 550216 6 01 Guldmann GB US 09 2012 550216 6 01 Turntable The turntable is used in rail systems where the hoist needs to run in several directions The turntable must not be used with the GH3 Twin hoist The GH3 hoist is placed in the center of the turntable By pressing the switch the turntable rotates 90 Press again and the turntable returns
20. diator or a water pipe The technician installer must then put on the bracelet and connect it to the mat If it is not possible to find a grounding point the mat and the bracelet must be used as a minimum Only then is it allowed to work with the PC Board or components where it is possible to come into contact with the PC Board Guldmann GB US 09 2012 550216 6 01 Guldmann GB US 09 2012 550216 6 01 1 08 Hold the lifting hanger in the right hand Insert the strap attachment in Rotate the strap attachment to a Check that the yellow button has returned Installation of the lifting hanger before use Lifting hangers from other manufacturers Guldmann shall not be liable for faults or accidents that may occur as a result of using lifting hangers made by other manufacturers If there is any doubt about the selection or use of a lifting hanger please contact your supplier The lifting hanger can be installed to the lifting strap without the use of any tools and press the yellow button using the thumb as shown Fig 1 the slot on the lifting hanger top cover with the open side facing down Fig 2a 2b and release the yellow button Fig 2c vertical position Fig 3 to its locked position by checking that it is flush with the cover of the lifting hanger and that the strap attachment can rotate freely 1 09 Lifting sling A lifting sling with four to six lifti
21. ediately below the display Then select gt until the Scale menu appears in the display Then select Start Park the hand control on the lifting hanger If the helper pulls the hand control during weighing this will affect the result of the weighing process When the lifting hanger with the lifting sling is at rest select Zero to reset the GH3 scale module The scale module has now been reset and weighing can commence 22 Guldmann GB US 09 2012 550216 6 01 Guldmann GB US 09 2012 550216 6 01 Weighing Scale Scale KG a rS n _ 248 0 Always reset the GH3 scale module before weighing takes place see section entitled Resetting the unit Place the lifting sling on the user and attach it to the lifting hanger Lift the user with care Park the hand control on the lifting hanger Select Menu using the function key located immediately below the display and then select until the Scale menu appears in the display Then select Start When the sling and the user are at rest and hanging freely the current weight can be read on the display The weight can be read to an accuracy of 1 decimal place Select Exit to return to the main menu Note The display in the hand control switches off automatically after use approx 8 min 23 2 07 CLM module GH3 with statistical function for management use The GH3 with CLM module o
22. ef messages on the display on the GH3 with Service module These pop up s notify the user of upcoming and exceeded dates for service inspections Both Pop Up s appear immediately after the hand control has been Switched on Pop Up s before and after Service Date Next service Next service Service done 2008 04 22 2009 04 22 Pop Up 30 days The next service inspection must be undertaken within 30 days Select OK to return to the main menu returns automatically after approx 5 seconds Next service AU m ervice date If service is not performed G exceeded call service ex 2008 04 22 Pop Up Service date exceeded The date of the service inspection has been exceeded contact the Guldmann Service Team Select Exit to return to the main menu returns automatically after approx 5 seconds Attention If the service date is exceeded by more than 60 days the hoist makes an acoustic signal at any button activation The Acoustic signal can be disabled by the Guldmann Service and Information Consol software Note The display on the hand control will automatically revert to the screensaver after approx 8 minutes 27 2 09 Safety functions The emergency stop and emergency lowering device should only be used in an emergency In the event that it is necessary to use the safety functions the fault must be identified and rectified before the GH3 is taken into
23. erface mini USB 9 GH3 with horizontal drive motor Lift Lower Movement in the direction of the arrow on the GH3 information panel section 2 00 Movement in the direction opposite to the arrow on the GH3 information panel section 2 00 Function selection button section 2 05 supplementary modules Function selection button section 2 05 supplementary modules PDA interface mini USB 9 x Accessories to CLM module see Supplementary modules GH3 section 2 04 Guldmann GB US 09 2012 550216 6 01 Guldmann GB US 09 2012 550216 6 01 NA Parking the hand control When the hand control is not in use it can be placed on the lifting hanger Infrared remote control Lift Lower Movement in the direction of the arrow on the GH3 information panel section 2 00 Movement in the direction opposite to the arrow on the GH3 section 2 00 Note In order for the GH3 s lowering function to work the strap must be carrying a load equal to the minimum capacity for Guldmann s lifting hanger Transport running in the rail system P i TWO oS The GH3 is manually pushed forward in the rail system by the helper The GH3 with horizontal drive motor will run in the rail system when activated by the hand control remote control 2 04 Supplementary modules GH3 There a
24. gether 1 04 Load limits on GH3 system Read the label which indicate the maximum load limits for each component The components e g lifting hanger lifting sling etc labelled with the lowest load limit determines the maximum load limit for the entire system This maximum load limit must not be exceeded Please note that the max load may change when different components are used such as lifting hangers lifting slings etc 1 05 Qn E GKM Unpacking and Preparation Visual check of the GH3 If the GH3 is thought to be damaged upon eas eye reception the GH3 must 1 not be used before it E has been checked and approved by a qualified person or the Guldmann Service Team Contents of the box GH3 hoist Hand control 6 Transformer Manual Label for rail system 1 06 Placing a new GH3 Hoist in an existing rail system Please notice placing a new GH3 hoist in an existing rail system it must be ensured that The rated max load of the rail system must be equal or higher than the max load of the new hoist If there is no max load mentioned on the rail system the rail system must then be checked according to the guideline in the installation manual distance between bracket according to max load If the brackets are not visible then a load test with 1 5 x max load of the hoist must be performed minimum 20 min The deflection of rails must not be higher than 1 200 of the len
25. gth of the rail If it is not possible to do any of the above mentioned please contact Guldmann or their representative If the rail system can not be rated to the same max load as the hoist then extra brackets must be installed according to the installation manual distance between bracket according to max load Class equipment Fixed rail systems are class equipment and must be installed by a qualified technician or by Guldmann Service Team Equipment is disconnected from Supply Mains by breaking the mains breaker switch Class Il equipment Mobile equipment is class II epuipment marked with double encassed symbol and can be connected to the mains direct by the user Equipment is disconnected from Supply Mains by detaching the mains plug from the wall outlet Emergency stop device The emergency stop device must be reset in order to connect power to the product To do this push the yellow reset button see point 2 09 1 07 Power supply GH3 is equipped with batteries that require regular recharging The power supply for charging and the battery charging point must be connected by a qualified engineer or by Guldmann Service Team The transformer supplied must always be used Safety concerning static electricity ESD Service technicians and installers must use an ESD safety package consisting of a mat a ground wire and a bracelet The technician installer connects the mat to a grounding point for instance a ra
26. m the selection by pressing OK Select to return to the start menu The display in the hand control switches off automatically after use approx 8 min See the complete menu summary section 2 04 Supplementary modules GH3 Scale module GH3 with integrated scale module The GH3 with scale module option provides the facility to determine the user s weight Warning The integrated scale in GH3 is not approved to determine mass in medical practice including the weighing of patients in connection with health moni toring diagnosis and medical treatment The provisions for medical weighing are specified in accordance with EEC Directive 90 384 Shock effects The GH3 with scale module includes high sensitive sensors to register mass corresponding to the nominal recommended load The sensors are highly sensitive and can be damaged by the effects of shock for example pulling the GH3 at extreme speed into an end stop Operation Always reset the GH3 scale module before weighing takes place When resetting the unit the lifting hanger and the desired lifting sling must be attached under the hoist 21 Resetting the unit tara Scale Scale KG Scale KG a P n 2480 0 0 Press any key on the hand control to activate the hoist When the lifting module is activated a display on the hand control is Switched on and the Guldmann logo G appears Select Menu using the function key located imm
27. mergency lowering will work with following load GH3 up to 250 kg 550 Ibs from approx load 80 kg 176 Ibs GH3 from 300 kg 660 Ibs from approx load 120 kg 264 Ibs When releasing the red strap the emergency lowering function will be replaced by the emergency stop Emergency lowering function mechanical If the electrical emergency lowering function in the GH3 fails the emergency lowering can be done mechanically Release the side covers from the top of the hoist by means of a gentle push on the fixing points on each side The covers are tipped free of the hoist and can be removed the handle bearing the words EMERGENCY DOWN This handle is located immediately behind the side cover and must be turned clockwise Note For hoists with a recommended load of more than 250 kg 550 Ibs there are two motors and therefore two handles to activate one on each side 29 3 When the brake s has have been released the user will be lowered slowly If the total weight of the user and the lifting accessories is low e g less than 50 kg 110 Ibs it may be necessary to help the user down by turning the large belt wheel located on the opposite side of the handle and in the direction of arrow marked on the belt wheel Note A GH3 with a recommended load of more than 250 kg 550 Ibs has two motors and therefore two belt wheels to activate one on each side Warning After the mechanical emergency lowering fun
28. ng straps designed for mounting on hooks should be used when using a Guldmann lifting hanger Place the straps on the hooks Make sure that the rubber safety catch returns to its start position so the straps can not unintentionally fall off Slings made by other manufacturers Guldmann shall not be liable for faults or accidents that may occur as a result of using lifting slings made by other manufacturers If there is any doubt about the selection or use of a lifting sling please contact your supplier Guldmann shall not be liable for faults or accidents due to incorrect use of the lifting sling or for reasons of inadequate attention on the part of the carer or user Working with the GH3 The GH3 runs easily in the rail system and does not have any special requirements for space or power in connection with moving Attention can thus be fully focused on the user s functional level and the helper s technique If the hoist is used correctly the user should only be lifted to the extent that she he is clear of the surface and should be moved at this height Attaching the lifting sling Place the straps from the lifting sling on the hooks on the lifting hanger Start with the uppermost set of straps from the back and then take the lowest set of straps from the legs Caution Be careful when attaching the lifting sling on the hooks Check that the straps have been pulled com pletely through the rubber safety catch A and into place
29. ption includes a management tool that saves important information on the use of the lifting module and which can be used to evaluate the system s efficiency and utilisation as well as to optimise its use and hoist name location The following data can be shown on the hand control s display number of lifts number of heavy lifts number of lifts in last week average number of lifts per week As an additional option by connecting a PDA Net Book to the hand control it is possible to gain access to a number of other saved data e g the number of lifts since the last strap change number of critically low battery readings number of weighings total lifting time etc This information can be downloaded and used for further analysis PDA Net Book readouts requires a PDA Net Book with Guldmann CLM software Number of lifts total A lift is registered automatically when the following events are registered simultaneously Hand control is activated Direction UP for more than 2 seconds The load on the lifting strap is registered as being within the range 15 kg Recommended load kg 33 Ibs Recommended load Ibs Total includes the number of lifts performed after the lifting module was first taken into use Number of heavy lifts total A heavy lift is registered automatically when the following events are registered simultaneously Hand control is activated Direction UP for more than 2 seconds The load on the lifting st
30. rap is registered as being within the range 150 kg Recommended load kg 330 Ibs Recommended load Ibs Total includes the number of heavy lifts performed after the lifting module was first taken into use Number of lifts last week The total number of lifts performed within the last seven calendar days Average number of lifts per Average number of lifts per week performed after week the lifting module was first taken into use The data for Number of lifts last week and Average number of lifts per week can if necessary be reset using a PDA Net Book 24 Guldmann GB US 09 2012 550216 6 01 Operation CLM 1 5 CLM 2 5 CLM 3 5 CLM 4 5 CLM 5 5 Lifetime Lifetime Last week Lifts per total lifts heavy lifts total lifts week avg Hoist ID 987 232 60 72 Hob 1 5 2 5 3 5 4 5 5 5 Number Number Number Average Hoist ID of lifts of heavy lifts of lifts last week numbers total total of lifts per week 1 Press any key on the GH3 hand control to activate the hoist When the lifting module is activated the display on the hand control is switched on and the Guldmann logo G appears 2 Select Menu using the function key located below the display 3 Then select until the CLM menu appears in the display 4 Then select Show 5 Then select Next until the required information appears in the display 6 Select Exit to return to the main menu Note The display on the hand
31. re various supplementary modules for the GH3 Scale module GH3 with integrated scale m CLM module GH3 with statistical function for management use Service module GH3 with Service module i Menu structure Supplementary modules GH3 Detailed description follows in sections 2 05 2 09 Pop ups Next service 2008 04 22 O O Service date exceeded call service is OO O O No charging O O Critical low battery Fault hoist OO f A O CLM CE CLM 1 5 Lifetime total lifts 987 CLM 2 5 Lifetime heavy lifts 232 CLM 3 5 Last week total lifts Hoist ID Hoist 1 Guldmann GB US 09 2012 550216 6 01 Guldmann GB US 09 2012 550216 6 01 Next service 2008 04 22 Setup Units Language English Language 1 8 Language 4 8 Italianio OK Q Language 5 8 Espanol po Language 2 8 Deutsch Language 3 8 Svenska Language 6 8 Francaise Language 7 8 Portuguese BR Language 8 8 English 2 05 Configuration of supplementary modules GH3 Before the GH3 is put into use the hoist must be configured Configuration covers language Scale module CLM module Service module and the unit for specification of weight Scale module Factory setting Language English UK Unit of weight kg
32. s top is at the same height as the top of the user s head Now position the sling over the user so that the centre band follows the user s spine Turn the user onto his or her back and pull out the remaining part of the lifting sling Place the leg straps beneath the user s thighs and cross them All four lifting straps are now ready to be attached and the lifting sling can now be mounted on the lifting hanger It is an advantage to elevate the head of the bed so that the user is sitting up Only persons who have received competent instruction regarding the use of lifting equipment and fitting of slings should use the hoist Important Plan the move Avoid leaving the user in the lifting sling unattended The GH3 lifts quickly and powerfully Before lifting check that the user is completely free of his her surroundings The user s head arms hands and feet must not be in danger of becoming trapped Be careful with any tubes and wires that are attached to the user Check that the hand control and hand control cable is free of hanger patient and other object before the hoist is activated up or down moved 11 1 10 Swing kit The swing function is used in conjunction with a transfer e g through a door from one lifting module to another Note The swing adapter must be ordered separately Installation of swing adapter Before starting a lift involving a swing transfer the swing adapter Fig 1 must be installed on the lifting
33. tention to the well being of the user when using the hoist The hoist is used in rail systems which are installed tested and approved according to Guldmann s stipulation Only technicians who have been certified by Guldmann may install and test the rail systems The hoist is used with the Guldmann lifting hanger or with other suitable hanger section 1 08 The hoist is used with a Guldmann lifting sling or with other suitable slings section 1 09 1 03 Important Precautions Read the instructions carefully before using the GH3 and in connection with cleaning and service of the hoist The GH3 s maximum load must never be exceeded The GH3 may only be used to lift a person The red strap for the emergency stop and the emergency lowering must be adjutsed to the helpers reach and must not be removed The GH3 must not be used where there is a risk of it being splashed with water If a defect appears during use of the GH3 stop using the hoist and contact the Guldmann Service Team for repairs The GH3 is controlled by a micropro cessor PCB which can be damaged by static electricity if touched without the necessary precautions see point 1 07 The electronics may only be serviced by Guldmann approved service technicians Guldmann GB US 09 2012 550216 6 01 Guldmann GB US 09 2012 550216 6 01 Re EMC If electromagnetic or other influences occur between this product and other products these products must not be used to
34. that the lifting device functions will meet your requirements be uninterrupted or error free The warranty set forth is in lieu of all other express and implied warranties whether oral written or implied and the remedies set forth above are your sole and exclusive remedies Only an authorized officer of Guldmann may make modifications to this warranty or additional warranties binding on Guld mann Accordingly additional statements such as advertising or presentati ons whether oral or written do not constitute warranties by Guldmann Service or Repair Contact Guldmann Repair for an authorization to return any defective item during the Warranty Period You will be provided with a return authorization number and address for returning the item for warranty service or replace ment Do not return items to Guldmann under warranty without receiving a Return Authorization Number 40 Guldmann GB US 09 2012 550216 6 01 Guldmann GB US 09 2012 550216 6 01 If mailing the item pack it carefully in a sturdy carton to prevent damage Include your Return Authorization Number a brief description of the problem and your return address and phone number Guldmann does not assume the risk of loss or damage while in transit so it is recommended you insure the package 41 Guldmann GB US 09 2012 550216 6 01 Time to care I taylor tel 0845 838 0600 email info taylordolman com www taylordolman com
35. y protection usse n a darken die Automatic Power SUBIN cese rated rre dae Ea i Bae 33V AC 2 5 A Supply voltage transformer 100 115 230V AC 50 60 Hz Batten csse Au dE RNN Rex AERE pea 24V NiMH SWL 200 kg 440 Ibs 250 kg 550 IDe KR RR K RRR 2 8Ah SWL 300 kg 660 Ibs 350 kg 770 Ibs 0 R 0 aR 0 R 0 5 6 Ah Continuous operation with short time loading with 3 hours without recharging 10 9096 2 min operation 18 min pause Max number of lifts in series with 85 kg 197 IbS a rh n Lees 55 1000 mm 39 4 inch SWL 200 kg 440 Ibs 250 kg 550 Ibs 28 1000 mm 39 4 inch SWL 300 kg 660 Ibs 350 kg 770 Ibs 40 1000 mm 39 4 inch Max charging time at 25 C SWL 200 kg 440 Ibs 250 kg 550 Iba nananana nanana 2 hours SWL 300 kg 660 Ibs 350 kg 770 lbs nnana nannan 4 hours Operating temperature esses 10 C 35 C 50 F 95 F Degree of protection against harmful ingress of liquids water ONS Css sonans er puer m prre ope E e vn ded o Y eben aoe IP 20 Harid conttol secet ud qe ote beh p at aa dora dec IP 44 Remote Control 234220045 raai Eae ER UPPER E EE us IP 20 TANS TOOTING ae ee sas pate ens ei sten cate vaio A ERE e Ee IP 20 EC Declaration of conformity The products are manufactured in compliance with the Council Directive 93 42 EEC of 14 June 1993 with amendments as medical device class 1 39 USA and countries outside the EU