UPSmon UPS Monitor and Control System User`s Manual MilPower
Contents
1. Configuration Server IP Address f 92 168 10 49 p Status Input Status Normal Output Status Normal CES enamine enor an UPSTemp 43 C Enterthe Workstation Shutdown Delay cana Command WorkStation Shutdown delay s fa Re UPS Charge threshold for shutdown 45 Battery MH I Initiate Shutdown when UPS or Server comm fails UPSmon User s Manual MilPower Source Edition 14 Figure 24 UPSmon User s Manual MilPower Source Edition 15 Chapter 5 Server service operation General View The server service displays the following UPS data Input Status Normal Mains failure Output Status Normal On Battery Failure Charge Level Estimated charge level of the UPS Load level Estimated load level on the UPS UPS Temperature UPS s temperature center grade Battery Status Normal Low Depleted The following warnings are supported Battery failure Over temperature Internal failure rConfiguration UPSIPAddress f 19216810204 2 rStatus Input Status Normal Output Status Normal Charge Level Above 95 Load Level Below 15 UPS Temp Bse Battery Status Normal Battery W OverTemp MM Internal Failure B rCommand UPS Shutdown delay s f 5 UPS Charge threshold for shutdown e5 d V Enable Server Self Shutdown Figure 25 UPS selection Hitting the UPS IP address command button
2. Time before shutdown 00 00 53 UPS Temp Battery HM OverTemp B Internal Failure fi Command UPS Shutdown delay s jis SE i UPS Charge threshold for shutdown 95 V Enable Server Self Shutdown Figure 30 If the Enable Server Self shutdown check box is checked the server will shutdown after all clients have completed their shutdown delay UPSmon User s Manual MilPower Source Edition 19
3. will prompt the user to enter the UPS IP address which is the UPS SNMP Agent IP address UPSmon User s Manual MilPower Source Edition 16 MJUPS Monitor Server AUPS Monitor Server x Configuration Enter the UPS ip Address UPS IP Address 0 7 Status came Input Status N Charge Level Above 95 Load Level Below 15 UPS Temp fare Battery Status Normal Battery HM overTemp HM Internal Failure E Command UPS Shutdown delay 5 jis oi UPS Charge threshold for shutdown fas x T Enable Server Self Shutdown Figure 26 UPS Shutdown delay Hitting the UPS Shutdown delay command button will prompt the user to enter the delay after which the UPS will shutdown the delay will start after the last client has been turned off The delay is entered in Seconds EN Configuration UPS IP Address 192 168 10 204 zi Status UPS Monitor Server x Enter the UPS Shutdown Delay Input Status Charge Level UPS Temp cancel Batey HM OverTemp M Internal Failure B Command UPS Shutdown delay S lis UPS Charge threshold for shutdown as aX I Enable Server Self Shutdown Figure 27 UPS Charge Threshold Hitting the UPS Charge Threshold command button will prompt the user to enter the threshold below it the UPS will launch the shutdown procedure UPSmon User s Manual MilPower Source Edition 17 The entered value w
4. UPSmon UPS Monitor and Control System User s Manual MilPower Source Edition UPSmon User s Manual MilPower Source Edition User Manual for UPSmon Version 1 01 UPSmon User s Manual MilPower Source Edition Contents Chapter 1 Introduction fee RE Features LiSt cccccscscscess Chapter 2 Server Installation Chapter 3 Client Installation Chapter 4 Client service operation General View cccccecececcececes Shutdown server selection Client Shutdown delay Chapter 5 Server service operation General View sscsscccssceeeeees UPS selection 2 0 00002 UPS Shutdown delay UPS Charge Threshold Server Self shutdown UPSmon User s Manual MilPower Source Edition Chapter 1 Introduction General The UPS Monitor is a client server application Client PC I UPS Monitor Client e service UPS Monitor Server Milpower a SourceUPS SNMP Agent Figure The Server service constantly polls several MIB variables from the UPS agent The Server also listens to Client requests and for each request it delivers the full set of parameter values to the Client The Client constantly polls the parameters from the Server and displays them in its GUI Upon discovery of UPS discharge explained later it will start a delay coun
5. cut will be placed Setup MPS UPS Monitor Server 1 01 00 co x Select Start Menu Folder Ke Where should Setup place the programs shortcuts lt Select the Start Menu folder in which you would like Setup to create the programs shortcuts then click Next MPS UPS Monitor Server Accessories Administrative Tools Adobe AdventNet SNMP Utilities Comfy Interactive Movies IV Create shortcuts for all users Back Next gt Cancel Figure 6 UPSmon User s Manual MilPower Source Edition 7 The server program is installed as an operating system service The user may choose to automatically launch it upon boot up if not the user must activate this service manually Setup MPS UPS Monitor Server 1 01 00 210 x Windows Services A Please choose the details of how the services should be installed V Install service MPS UPS Monitor Server IV Start on bootup Back Next gt Cancel Figure 7 At the final phase the program will self extract the compressed file and complete the installation process this phase may take several minutes depending on the workstation s speed Ps installjWizerd a MPS UPS Monitor Server is preparing the install4j g Wizard which will guide you through the rest of the setup process Cancel Figure 8 gt Setup MPS UPS Monitor Server 1 01 00 iol xj Completing the MPS UPS Monitor S
6. e Configuration Server IP Address 192 168 10 49 Status Input Status Fail Output Status lon Battery Charge Level above 95 Load Level f 01 115 following manner UPS Temp 42 c Battery Status Normal Bater MH OverTemp ME Internal Failure ME Command WorkStation Shutdown delay s fit UPS Charge threshold for shutdown 45 I Initiate Shutdown when UPS or Server comm fails UPSmon User s Manual MilPower Source Edition 13 Figure 22 Shutdown server selection Hitting the Server IP address command button will prompt the user to enter the IP address of the shutdown server the workstation where the UPSmon server service has been launched ZaUPS Monitor Client ZAUPS Monitor Client x Enter the Server ip Address Configuration Fo Server IP Address CZS cares Status Input Status Normal Output Status Normal Charge Level fabove 95 Load Level 101 115 UPS Temp 43 c Battery Status Normal OverTemp M Internal Failure W WorkStation Shutdown delay s 11 a UPS Charge threshold for shutdown 45 I Initiate Shutdown when UPS or Server comm fails Figure 23 Client Shutdown delay Hitting the Workstation Shutdown delay command button will prompt the user to enter the delay after which the workstation will shutdown The UPSmon program allowes different client services to hold different delay values The delay is entered in Seconds raus montor cient E
7. erver Setup Wizard Setup has finished installing MPS UPS Monitor Server on your computer The application may be launched by selectingthe installed icons Click Finishto exit Setup Finish Cancel Figure 9 UPSmon User s Manual MilPower Source Edition After the install process has finished the program s icon will appear in the system tray ee Figure 10 The user may click on the icon and select from the following options e Show Maximize the MPS service view e Exit Terminate the MPS service To complete the installation process the user is prompted to restart the workstation in order for the new service to be in effect Setup ee 9 To complete the installation of MPS UPS Monitor Server Setup must restart your computer ve Would you like to restart now Figure 11 Chapter 3 Client Installation The client install application MPS_UPS_CLIENT_windows_1_01_00 exe in the attached disk operates as a graphic wizard which enables easy installation without the need for extensive definitions During the first stage the install application will be loaded to the workstation s memory and the following screen will be displayed for several minutes depending on the workstation s speed GET MPS UPS Monitor Client is preparing the install4j Wizard which will guide you through the rest of the setup process ITT TTT iii Figure 12 UPSmon User s Manual MilP
8. ill be rounded to the nearest charge indication possible by the UPS The threshold is entered in percentage 0 100 Configuration UPS IP Address 192 168 10 204 Status Input Status Normal Output Status Normal Charge Level Ab a UPS Monitor Server UPS Temp at Enterthe UPS Charge Threshold oy M care Command UPS Shutdown delay S fis e UPS Charge threshold for shutdown fas I Enable Server Self Shutdown Figure 28 Server Self shutdown Checking the Enable Server Self Shutdown box will cause the server to shutdown after all clients have completed their shutdown delay Note This feature is important in cases where the server in not backed up by the UPS it is monitoring UPS Monitor Server The Server Will Shutdown in 29 Seconds Input Status Fail Output Status on Battery Charge Level 35 94 Load Level fi 01 115 UPS Temp 38 c Battery Status Normal Battey HM OverTemp B Internal Failure fi Command UPS Shutdown delay s 15 a UPS Charge threshold for shutdown o5 V Enable Server Self Shutdown Figure 29 UPSmon User s Manual MilPower Source Edition 18 rr aUPS Monitor Server Configuration UPS IP Address f1 92 168 10 204 oe Status The system is shutting down Please save all Input Status work in progress and log off Any unsaved changes will be lost This shutdown was initiated by WEB SZKL3ZKQTO3 Michael Charge Leve
9. k Finish to exit Setup Finish Gance Figure 18 After the install process has finished the program s icon will appear in the system tray gd Figure 19 The user may click on the icon and select from the following options e Show Maximize the MPS service view e Exit Terminate the MPS service UPSMon Client v1 01 00 Show Exit wD Figure 20 Chapter 4 Client service operation General View The client service displays the following UPS data e Input Status Normal Mains failure e Output Status Normal On Battery Failure UPSmon User s Manual MilPower Source Edition 12 e Charge Level Estimated charge level of the UPS e Load level Estimated load level on the UPS e UPS Temperature UPS s temperature center grade e Battery Status Normal Low Depleted The following warnings are supported e Battery failure e Over temperature e Internal failure KAUPS Monitor Client JE Configuration Server IP Address fi 92 168 10 49 Ms Status Input Status Normal Output Status Normal Charge Level above 95 Load Level fi 01 115 UPS Temp 41 c Battery Status Normal Battey HM OverTemp ME Internal Failure i Command WorkStation Shutdown delay s fa Pe UPS Charge threshold for shutdown 45 I Initiate Shutdown when UPS or Server comm fails Figure 21 For example turning the mains off will update the data in the client service in th
10. ower Source Edition After the completion of the install download process a Welcome screen will be displayed in which the user is prompted to continue with the setup or abort it Setup MPS UPS Monitor Client 1 01 00 E oj x Welcome to the MPS UPS Monitor Client Setup Wizard This will install MPS UPS Monitor Client on your computer It is recommended that you close all other applications before continuing Click Next to continue or Cancel to exit Setup Figure 13 Pressing the Next button will prompt the user to select the folder where the application will be installed The default location is c Program Files MPS_UPS_ CLIENT The User may select another path by typing it in Setup MPS UPS Monitor Client 1 01 00 Select Destination Directory Where should MPS UPS Monitor Client be installed Select the folder where you would like MPS UPS Monitor Client to be installed then click Next o Program FileswiPS_UPS_ CLIENT ip Program Files E Adobe gd Common Files gd ComPlus Applications aA ComponentSoftware aA Ethereal FileZill a wa vi j Local Disk C v The program requires at least 49 19 MB of disk space Back Next Cancel Figure 14 The user can select the start menu folder where the program s shortcut will be placed UPSmon User s Manual MilPower Source Edition 10 Setup MPS UPS Monitor Client 1 01 00 Select Start Menu Folder Ahere
11. ry and the following screen will be displayed for several minutes depending on the workstation s speed install4j Wizard MPS UPS Monitor Server is preparing the install4j od Wizard which will guide you through the rest of the setup process i Figure 3 After the completion of the install download process a Welcome screen will be displayed in which the user is prompted to continue with the setup or abort it UPSmon User s Manual MilPower Source Edition 6 Setup MPS UPS Monitor Server 1 01 00 a oj x Welcome to the MPS UPS Monitor Server Setup Wizard This will install MPS UPS Monitor Server on your computer tis recommended that you close all other applications before continuing Click Next to continue or Cancelto exit Setup Figure 4 Pressing the Next button will prompt the user to select the folder where the application will be installed The default location is c Program Files MPS_UPS_SERVER The User may select another path by typing it in Setup MPS UPS Monitor Server 1 01 00 Select Destination Directory me Where should MPS UPS Monitor Server be installed E AdventNet El Common Files E ComPlus Applications 1 Dallas Semiconductor C Ethereal E izi Internet Solutions x s r Local Disk C v The program requires at least 49 45 MB of disk space Figure 5 The user can select the start menu folder where the program s short
12. should Setup place the program s shortcuts Select the Start Menu folder in which you vould like Setup to create the program s shortcuts then click Next Accessories Administrative Tools Microsoft Office Tools p IV Create shortcuts for all users Back Next Cancel Figure 15 The client program is installed as an operating system service The user may choose to automatically launch it upon boot up if not the user must activate this service manually Setup MPS UPS Monitor Client 1 01 00 Windows Services Please choose the details of how the services should be installed IV Install service MPS UPS Monitor Client V Start on bootup Back Next Cancel Figure 16 At the final phase the program will self extract the compressed file and complete the installation process this phase may take several minutes depending on the workstation s speed Setup MPS UPS Monitor Client 1 01 00 Installing Please wait while Setup installs MPS UPS Monitor Client on your computer Extracting files jucheck exe BEE Cancel Figure 17 UPSmon User s Manual MilPower Source Edition 11 Setup MPS UPS Monitor Client 1 01 00 DP xt Completing the MPS UPS Monitor Client Setup Wizard Setup has finished installing MPS UPS Monitor Client on your computer The application may be launched by selecting the installed icons Clic
13. ter and then shutdown the PCs Client PCs using the psshutdown utility The Server and Client have an identical GUI with only slight differences UPSmon User s Manual MilPower Source Edition Features List The UPSmon main highlights Constant monitoring of the UPS Different client delay settings Configurable UPS remote shutdown Forced shutdown of remote workstations A typical installation follows in the illustration below The EmbedUPS adapter installed inside the UPS communicates with the UPS informing it on various power conditions UPS a iiil EmbedUPS C NMS station Figure 2 UPSmon User s Manual MilPower Source Edition Minimum system requirements Processor Pentium III 700 MHz Memory 256MByte Screen SVGA 1024 768 32bit Available disk space 100Mbyte Operating system Windows XP NT 2K Chapter 2 Server Installation The server install application MPS UPS SERVER windows 1 01 0Q0 exe in the attached disk operates as a graphic wizard which enables easy installation without the need for extensive definitions During the first stage the install application will be loaded to the workstation s memo