Home

ASSEMBLY INSTRUCTIONS (Pdf - 572 Ko)

image

Contents

1. ark the point with a pen 2 Mark the area over which you want to apply the glue using adhesive tape Ensure that the surface is perfectly clean and that the marked bonding area is the same shape as the canvas patch 3 Remove grease from the surface to be glued 4 Apply the glue to the canvas patch You can use a small brush 5 Apply the glue to the inflatable track over the marked area 6 Once the glue is dry after 10 15 minutes remove the adhesive tape 7 Place the patch on the area and press hard 8 Press hard in one direction to obtain good adherence and remove any air between the two materials 9 You can use the inflatable track again after four hours drying at ambient temperature GYMNOVA CS 30056 45 rue Gaston de Flotte 13375 Marseille Cedex 12 Tel 33 0 4 91 87 51 20 Fax 33 0 4 91 93 86 89 info gymnova com www gymnova com
2. cYmnow USER MANUAL To improve the safety and service life of your inflatable track it is important to read the entire user manual and use this product according to the directions These safety rules will help you make the most of your inflatable track over many years For any questions or requests for further information please contact us www gymnova com SAFETY INSTRUCT The inflatable track must be installed by authorized or competent persons only Always check that the surface is clean dry and uniform If outdoors always lay a tarpaulin under the inflatable track and check there is nothing that can puncture the track surface To move the inflatable track use the handles on the sides Never drag the inflatable track on the ground Use of the inflatable track must always be properly supervised Ensure that the inflatable track is always cleaned dry and properly stored Do not use the inflatable track wearing hard soled shoes or shoes with heels The track should be used barefoot or with suitable flexible shoes If you use a pressure gage during inflation remember to remove it before the track is used Place the safety mat at the end of the track PACK CONTENTS FOR 10 cm amp 15 cm TRACKS e 1 compact inflator with yellow hose for 10 cm track and black hose for 15 cm track e 1 pressure gage Tightening wrench repair kit 1 transport bag FOR 20 cm TRACKS e 2 compact inflators each wi
3. e valves to help evacuate air WARNING Switch the inflator off immediately if you hear the motor straining to avoid risk of damage 6 Remove the inflator and other accessories 7 FOLD the track in half lengthwise to let air escape The more air you get out the more compact the rolled mat DEFLATION CONTINUED 8 Start to roll the track towards the valves 9 Close all the caps to avoid the risk of damaging or losing them 10 When the inflatable track is fully rolled up pack it into the transport bag 11 Ensure the bag s straps and opening are facing upward 12 Fasten the straps starting with those on the small sides and finishing with those on the side with the carry handles 13 Your inflatable track is now ready to be transported or stored REPAIR 7 REPAIR KIT CONTENTS Fast bonding glue 1 piece of gray canvas 1 piece of blue PVC 1 Key for valve repair The surface of the inflatable track is manufactured from PVC and canvas If used inappropriately it may become damaged For example small holes caused by grit on the floor can easily be repaired By making correct use of the above repair kit not requiring any professional skills you can repair small leaks easily and with long lasting effectiveness The key can be used for replacing a gray valve or for re tightening RECOMMENDED USE 1 Identify the point of puncture on the inflatable track by spraying soapy water over the PVC surface and then m
4. n the inflatable track the more it absorbs impacts and the less flexible it becomes see guidelines in the table 8 You can ascertain the exact pressure using a pressure gage Connect the pressure gage to one of the gray valves clipping in the tip by simply rotating it Do not use the pressure gage when the inflatable track is iN use ADJUSTMENT OF RIGIDITY for reference ABLE TRACK 10 cm ABLE TRACK 15 cm ABLE TRACK 20 cm TOO MUCH PRESSURE use the central ventilation fan switch Gray valve Remove the gray cap and exert pressure on the central ventilation fan switch press again to close it Black valve Remove the black cap press the central ventilation fan switch and turn it clockwise until you hear a click Press and turn again in the other direction to close it NOT ENOUGH PRESSURE you can add a little more air by using the inflator with the yellow or black hose DEFLATION 1 The track must not be used during deflation 2 VERY IMPORTANT Open ALL the valves to allow as much air as possible to escape 3 Connect the inflators to the IN connection of the inflator 4 Connect the tip of the hose into the valve by a simple rotation action and switch the inflator on There must always be a person present during deflation Repeat the same operation with the second inflator if you have a second one 5 Ensure there is enough space around the valves Slide a mat over the track in the direction of th
5. th black hose 1 yellow hose e 1 pressure gage e Tightening wrench repair kit Transport bag INFLATION It is important that someone stays by the inflator during the inflation time ready to switch it off as soon as the maximum pressure is reached and so avoid risk of damage 1 Unfasten the external and internal straps of the transport bag 2 Unroll the inflatable track and remove the transport bag 3 Unfold the track take note of how it is folded so that it can be folded the same way for storage 4 Connect the inflator s connect the hose yellow or black depending on the model to the OUT connection on the inflator OUT connection 5 Connect the inflators to the valves For 15 cm and 20 cm tracks Open the valve by unscrewing the external black cap Attach the hose to the black valve by turning the ring clockwise Repeat the same operation with the second inflator if you have a second one For 10 cm tracks Connect the tip of the hose into the gray valve by a simple rotation action the valve will open automatically and switch the inflator on The valve will close automatically when you remove the hose This prevents any air escaping Press the center of the valve if it does not close automatically The track inflates within a few minutes depending on its size specific requirements and level of users 7 Reseal the valve with the external cap INFLATION CONTIN The higher the pressure i

Download Pdf Manuals

image

Related Search

Related Contents

Honeywell W7753A Ventilation Hood User Manual  Masonite 28206 Instructions / Assembly  DIGITAL SNAKE S16  下糸の準備  ダウンタウン熱血行進曲 それゆけ大運動会  USER MANUAL  DSP56F827, 56F827  Extensions and Modul..  RI2084 - Angeloni  Kit d`analyse de la concentration en glycol Vacu-vials  

Copyright © All rights reserved.
Failed to retrieve file