Home
OLP Manual - PC Industries
Contents
1. Select the type of file to load The choices are TIF BMP or PDF format Select the file then press Open Title Guardian Offline Proofing Software User Manual Ret Issue Release Date June 2011 Revision 4 03 4 Scan Settings Optional Click on the Scan Master button after selecting input type at the top of the screen and the following dialog box will appear The recommended setting is 600 Scan DPI dots per inch but 400 DPI can be used for faster speeds at a lower quality setting There are also setting of 100 DPI and 200 DPI which can be used for large format images The Master Image resolution should be at the selected dpi or higher The software will automatically convert the resolution of the input file to match the selected resolution Scan Contrast and Scan Brightness settings are used to adjust the scan to match the master image quality The W width and H height settings is provided in inches and can be set to match the sample size The Test Box Mask is used to mask the edges of the region of interest This setting can be changed after the master setup is complete and the mask is displayed when toggling to the master image after the inspection is complete Resize Image is used to adjust test images to match master images when not input at 10096 scaling Scanner Selection Box is used to indicate the type of Scanner There are two selections flatbed and large format scanner settings Scanner scan Contra
2. 3 Object Search in pixels Area of Object box movement The higher the number allows for coarser alignment of the test boxes at the expense of inspection processing time 4 Object Accept percentage Value required for a locate accept The higher the value the more accurate the lower the value the higher chance of locating incorrectly 5 Object Edge in grayscale Used to detect the object edge contrast value on the master image Set lower to detect lower contrast objects 6 Max Object Size in pixels Maximum size of an Object 7 Auto Object Contrast Un check to manually control the Contrast setting for Objects 8 High Object Sensitivity Provides an alternate method of Auto Object Contrast which will tend to be more sensitive to contrast differences between the test image object and the master object 9 High Bkgd Sensitivity Provides an alternate method of Auto Object Contrast which will tend to be more sensitive to contrast differences between the test image object and the master object Settings Image Rotation Load 3v Rotate CEW Rotate 180 Rotate CVV Scanner Settings c b YR Scanner scan Contras a Ju Flatbed Biz 2 scan Brightness 30 5 WM X 1 H Test Box 200 Rectangle 100 Resize Image Round Rect Elipse p00 j 24 Title Guardian Offline Proofing Software User Manual Ret Issue Release Date June 2011 Revision 4 03 5 Advanced Option Settings
3. PN 105789 Title Guardian Offline Proofing Software User Manual Ref Issue Release Date June 2011 Revision 4 03 12 Adjust Objects Optional After the software successfully trains then Add or Delete any objects Directions Installian inspection santo Supplement Facts ap AM E productionaindi duce Serving Size 1 Tablet ability Dororsipdefecst Servings Per Conitainer 120 0 102125 100750 n imatge Guardan OLP Amount Per Serving 02375 audi sgt some up POF 500 491125 02750 CAUTION Not for use by pies 401250 102875 unconcerned abot ual The Daily Value DV not establishe 101375 Ki 103000 Guardian PON provides tue 100 QV mate ne 01500 E 03125 peclontoensus Done f iiprirtied deal der pistola 016257 AUM gg The Master image must then be approved by pressing the Save Project button After approving the Project Save As dialog will automatically appear prompting the project to be saved as a file name for future use Enter a file name and click Save The Guardian project files will be saved in the OLP format which is a SQL Database file designed for the Guardian OLP 13 Save Project 11 Title Guardian Offline Proofing Software User Manual Ret Issue Release Date June 2011 Revision 4 03 14 Master Image Window After saving the project the master image will be displayed in the upper left window The open project name will also be displayed under the
4. 001 T lor neis TEGA sing t het na ii eau The Guardian PQV provides true 10096 inen actien tr anciivn Antfact_frvan Pant Position 87410842 roo A Hold Esc poe lo cancel Satin tage Foe image Diaplayed gt Result load RT fene iem fa Esas o j Tg Masia s J caia d Cetera Oen in Title Guardian Offline Proofing Software User Manual Ret Date June 2011 3 2 Starting a New Project Issue Release Revision 4 03 This section explains how to train a new master image 1 New Project Select the New button After you have selected the New button the Master Image buttons will be displayed 2 Choose Master Image Type The two choices are to Load Master from a file or Scan Master if there is a scanner attached to the computer When scanning a master you must select the desired DPI of the scan and either Color or Grayscale 3 Load Master Image Optional Click on the Load Master button after selecting input type at the top of the screen and the following dialog box will appear Organize Mew folder nd Favorites EE Desktop Je Downloads E4 Recent Places rdi241 1 001 Libraries Documents a Music Pictures BE Videos nE Compniter Item type TIFF image rd1241 Rating Unrated Dimensions 3400 x 4450 Size 350 KB File name rd1241 1 001 defect Image Files tif pdf bmp
5. sensitivity to small defects b Contrast Objects Background in grayscale levels the software will filter and ignore defects with a smaller contrast difference than this setting The lower the number increases the sensitivity to light contrast defects c Edges Object Background in pixels the software will filter and ignore defects on the edges of graphics or characters The lower the number increases the sensitivity to register defects Sensitivity Min Size Objects Min Size Background 10 0 25 1 Contrast Objects Contrast Background 130 LJ aa ig Edges Objects Edges Background gt y 10 5 23 Title Guardian Offline Proofing Software User Manual Ret Issue Release Date June 2011 Revision 4 03 4 Basic Settings Allows the system performance to be adjusted a Test Box Mask Select the shape of the test box there are three choices Rectangular Round Rectangular and Ellipse b Load Save Settings Allows the manager to load and save a set of default settings to be used for the current or a future project c Object Settings Manager Security Level 1 Object Search in pixels Area of locate box movement The higher the number allows for coarser alignment of the test boxes at the expense of inspection processing time 2 Object Accept percentage Value required for a locate accept The higher the value the more accurate the lower the value the higher chance of locating incorrectly
6. 0 11 39 AM E Videos Com puter E Local Disk C ti Network jE ALMA S CHRIS m Filename RD1241 1 olp Projects vpr olp v e 3 Choose Test Image Type The two choices are to Load Test from a file or Scan Test if there is a scanner attached to the computer 13 Title Guardian Offline Proofing Software User Manual Ret Issue Release Date June 2011 Revision 4 03 4 Load Test Image Optional Click on the Load Test button after selecting input type at the top of the screen and the following dialog box will appear A Open e Cv pm t Computer Local Disk C GuardianOLP Projects Scans Search Scan Organize New folder X Favorites Name Date Type ae Hrdtun rd1241 1 001 2 23 2010 11 39 AM TIFF image Downloads L E Recent Places i53 Libraries Documents a Music i Pictures BE Videos JE Computer Local Disk C i Network Filename rdl241 1 001 Image Files tf pdf bmp v lt Select the type of file to load The choices are TIF PDF and BMP Select the file then press Open 5 Scan Test Image Optional Click on the Scan Test button at the top of the screen and a dialog box from the scanner should appear indicating the scanner is acquiring the image 6 Rotate Test Image Optional Click on Rotate 90 CW to rotate the image rotate 90 degrees clockwise click on Rotate 180 to rotate the image 180 degrees and click
7. 1 INTFOGUCUION iei IE aiit Aft EH A eo 6 3 2 Starting a New Project ssssssssssssssssssssennn nnne nnne nennen nnns sn nha dann n rris nnns sane nnns aaa 7 Li NeW PrOJe oii oda adeo ea ai 7 2 Choose Master Image Type 2 9 4 4 amp amp eB 7 3 Load Master Image 8 f 89 9B 7 4 Scan Sedis uoo II cc a oos eoo 8 5 Scan Master Image 28 4 9 8 6 Rotate Master Image 9 9 4 598 ueeeeeseeeeeeeeseeeseseee enne nnns 8 7 Region of Interest Box 98 4 4 9 eeeeee nne 9 8 Position Region of Interest Box 9 Jr 9 4 9 9 Add Mask Button m 9 49 amp Mo ocoooccccoccoccconcnccnnonancnnononannc nn nnne nnn rs rernm eenen 10 10 Position Locate Boxes E AF 9 MW oooomooocooocococcocococoncncnncnncnnononannnnr nnn 10 11 Train Master 9 0 eese nnne nnnm nnne nn nnn nna 10 12 Adjust Oblecis M Ae so tere ten tbi ere tut ettet cdo 11 135 SAVE Proel e e e el 12 14 Master Image Window 4h cece cccccc ccc ccceccescseneesccesenenscasesceseeescaseeessceseesesouseeecsarsesoueees 12 3 3 Opening an BXigting Proje 4 ccccccccccessseeceecesesccccesseneeeeesccssseneeeeeseccoacsseeeeeeeessseseeneeess 12 1 Open PROBE CIO ooo cece ccc cceccnececeeceessccass
8. 2 Signature 20 Issue Release Revision 4 03 WIL ee P LI This quality ied PDF y printers lity The true 100 PIUUUCL curn against a cus CAUTION N unconcerned Guardian PQ inspection to chinmante Title Guardian Offline Proofing Software User Manual Ref Issue Release Date June 2011 Revision 4 03 3 4 Image Zoom Buttons The image zoom buttons are used adjust the operators view of the image being inspected Image Zoom Zoom In Zoom Qut Zoom Fit 1 Zoom in When zoom in is used the main viewing area displays an enlarged view of a specific portion of the image The more zoomed in the smaller the portion of the main image being viewed 2 Zoom Out When zoom out is used the area being viewed becomes larger Zoom out can will only work until the whole image is displayed in the main viewing area 3 ZoomFit When zoom fit is used the main viewing area displays the complete image being inspected 3 5 Image Displayed Buttons These buttons allow the operator to cycle through an inspected image the master image and a displayed image Image Displayed Test 2 f Master 3 1 Results 1 Clicking on this button or pressing the 1 button on the keyboard will display the inspection results 2 Test 2 Clicking on this button or pressing the 2 button on the keyboard will display the test image without the inspection results 3 Master 3 Clicking on this button or pressing the 3 button o
9. Report When enabled the OLP will automatically print a text only Report No Defect Chart Deletes defects to remove from reports Objects Number of objects trained Filtered Number of objects grouped i if i Options Objects Info 408 ms J Database File 7 Default Scanner Objects 794 0 7 Scanner UI Filtered 97 50 T 0 0 0 Large Master 3750 3002 3850 3102 100x100 Print Label Option 0 1 0 1 0 1 Auto Print Report 15 E Ho Defect Chart Mem 166 53 Mb 21
10. These settings used to adjust system performance and are only accessible to the system administrator When making changes to setting re inspection is necessary for the changes to take effect a Highlights When this option is enabled the OLP displays defect highlighting b Defect Boxes When this option is enabled defect boxes are displayed around all image defects c Group Defects When this option is enabled defects that are within the group defect spacing are grouped together d Locate Boxes When this option is enabled locate boxes are displayed showing alignment issues for an inspected image e Auto Find when this option is enabled the OLP will automatically find images from a loaded test file or scan f Auto Inspect When this option is enabled the OLP will automatically inspect images from a test file or scan Should be used in conjunction with Auto Find g Auto Skew When this option is enabled the OLP will provide automatic skew adjustments h X Autoscaling Allows automatic scaling along the horizontal axis i Y Autoscaling Allows automatic scaling along the vertical axis j Max Skew The maximum distance skew is allowed in Degrees k Find Accept The minimum acceptable match percent for Find Max Defects The maximum number of ant type of defect allowed in an Inspection The OLP will provide a message if this limit is exceeded m Update Rate This setting is the number of inspections plus
11. ace eat iodtunt ux a ral ood 21 3 ZOOM Plis is de tias deciden IR oat NOn dee 21 3 5 Image Displayed Buttons ssssss E ME e eee eue 21 Ts er Vu hh tm S iria 21 HEN Lu ny NEUEN dP n Qm 21 di Master 0 rp an 21 3 6 System Settings sss UP O 09e 22 1 Login Button osito hori RE Revo A ore 22 Zi L gin POPUP sir oni NE oe troia ial 22 3 Sensitivity Settings R FAN ese eet 23 A Basic Selllhds o io es A nent 24 5 Advanced Option Settings occconccccconnnccnnnnncconnnnnncnnnnnnnnnnnncnnnnnnnnnonnnnnnennnnnononenennnos 25 6 Advanced Object Settingsaff TTM m 99 i eeeeeueeeeeeeeusssseseeeseeeen nennen me nnn nn nsns nnns inanis 26 7 Advanced Information Settings seesssssseene enne nnne nnne 27 Title Guardian Offline Proofing Software User Manual Ref Issue Release Date June 2011 Revision 4 03 1 Introduction 1 1 Purpose and scope The purpose of this document is to briefly describe the functionality of the Guardian Offline Proofing software 1 2 Problem reporting instructions Record any on screen error messages and details on what was done to help duplicate the problem and call PC Industries at 1 847 336 3300 for tech support Title Guardian Offline Proofing Software User Manual Ref Issue Release Date June 2011 Revision 4 03 2 Installation amp Configuratio
12. al pixel size during object training Decrease this number to allow for smaller objects to be trained and inspected Increase this number to reduce the number of small objects trained Typical setting 4 to 10 b Object Border Sets the border area around found objects during object training Decrease this number to separate and inspect more objects independently Increase this number to enlarge the area around the object to be inspected at the object sensitivity level Typical setting O to 3 c Min Contrast is used to filter out low contrast objects A low minimum contrast will allow for recognition of a higher volume of objects while a high minimum contrast will recognize fewer objects Group Distance The distance in pixels objects will be grouped as a single object e Small Border This is the size of the border placed around small objects in pixels Small Object Size Objects with widths or heights less than this setting in pixels will have the small object border placed around them g Smooth Master When checked applies a smoothing algorithm to smooth edges for improved object training h Group Objects When enabled allows for the grouping of objects within the group distance i Ignore Inside Removes objects trained inside other objects j Objects This displays the total number of objects found in an inspection k Display Objects This displays the object locations on the master image for the last regio
13. ame color print Place the locate boxes as close to the corners as possible Use unique features to avoid confusion The lower locate box can be placed in either bottom corner com Directions Install an inspection ystern from PC Industries to improve quality reduce waste increase production and reduce Serving Size 1 Tablet liability Do not ship defects to Servings Per Container 120 your customers Important Proof read all product information using the Guardian OLP Amount Per Serving off line proofing system This product compares print quality Inactive Ingredients 500 mg against a customer supplied PDF Daily Value DV not established CAUTION Not for use by printers Do not use if imprinted seal under cap is broken or missing Supplement Facts unconcerned about quality The Guardian PQV provides true 100 inspection to ensure defect free shipments Lot Exp Se PC INDUSTRIES WI l ll Mi NETEEP SAL KEY ANUS O 12545 67891 2 www pcindustries com Inspection Systems Tip Right click on the image to bring up the Zoom controls Train Master After positioning the locates press the Train button to train Objects 10 00125 00250 00375 00500 00625 00750 00875 01000 01125 01250 01375 01500 01625 0175 0187 02000 02125 02250 02375 02500 02625 02750 02875 03000 3125 03250 c 5 E 2 t gt
14. eeeeeecsccasseneeeeeesessacasssaeeeeeescausseeeeeeesseescosseaseees 12 UMEESJC C b ambe 13 3 MOB est Image TYD6 ion petente dll 13 A Magee Vest celo iii daa a eee 13 BECA TES nv eet 14 B Oro ES AC eruca e sean taa cic dl n Re a cea ct xm au aac a saab t dd 14 7T Auto Find Number of IMAges ccoooocccccccooocccncccononccononononcnnnnnnonncnnnononancnnnononancnnnonnnnanons 15 8 Show Advance Position BUttON cccccccoonnncccccncccnnconnnnnonnononnnancnconnnnrnnnonnnnnronnnnnonanenss 15 9 Enter Number of Images vene er D ose A P eee vo ee Ya e ve ecu 15 10 Ada Test BOXES 5 no o e geli ae Deo enu reet 15 11 Adjust Test Box SDaCIIig oe iia ai dra aca irn ici 16 12 Objects Background Selection buttONS ooooooocccnncccccccooncconnnonononnnanncnnnnnononanccnnnnonnos 16 Title Guardian Offline Proofing Software User Manual Ref Issue Release Date June 2011 Revision 4 03 19 PerTorm InSpecUol tii ise eo eoa E orto Er voa pesa ad ovine Ue rn n e Mecca 16 i BUOM LE e trot 16 15 Save Project Button sees essen nennen nnne cocoa ees 16 15 Overview WIhOOW iode debi t aee ideal 17 17 Review Inspection ResSultS oococooococccococcccocnocccnocanocccnanccccnnc Me eese 18 3 4 Image Zoom Buttons occccoonoccccoconoconcaconononacaninana caco nanc coran AO n 21 1 ZOOIm oe a a a M eo ME m a 21 2 LOOM OUT eee wtd
15. f em PC INDUSTRIES 176 AMBROGIO DRIVE GURNEE ILLINOIS 60031 3373 USA Web Site www pcindustries com E Mail sales pcindustries com Phone 847 336 3300 Fax 847 336 3232 Guardian Offline Proofing System Software User Manual Document Reference Issue Release Revision 4 03 Document Date Jun 2011 PC Industries 176 Ambrogio Drive Gurnee IL 60031 USA Tel 1 847 336 3300 Fax 1 847 336 3232 http Awww pcindustries com Title Guardian Offline Proofing Software User Manual Ret Issue Release Date June 2011 Revision 4 03 This Page Left Intentionally Blank Title Guardian Offline Proofing Software User Manual Ref Issue Release Date June 2011 Revision 4 03 Table of Contents L iiigece U cy Co eae M RE 4 1 1 Purpose arid SCODO ir O 4 2 Installation amp Configuration lessen nnnm nns 5 2 1 Hardware and Software RequireMentS ccooooonnccccconccocoonnccnnnnonononononononnncononnnnnnnnnnnononannnennnoss 5 2 2 How to configure the application ccccccsescccceeeeeeeeeeeeeceeeeeeseeeeeeeensueessaugeeesseeeeenaueeeeeseeeeeas 5 2 3 Cleaning the scanner glass ccccccssssscceecccceesseeceeeccseeesasseeeeeeeseaasaaeceeesssssasadbassennessiousseeeesess 5 2 4 Connect SCANME ccsssecccscssserenccssersecnccssssesserscsssereccessersersss S L sees 5 39 USAGE tos cto PR NE Lo Ae eos 6 3
16. from PC Industries to Sup pleme nt Facts improve quality reduce waste d i increase production and reduce Serving Size 1 Tablet liability Go not ship defects to Servings Per Container 120 Our custorrers Important Proof nead all product ae information using the Guardian OLP off line proofing system This product compases paint quality against a customer supplied PDF CAUTION Not for use by printers unconcerned about quality The Guardian POW provides true 100 Inspection t ensure defect free shipments Lot Expe fes N eg wwvw pcindustries com Donat use if imprinted seal under cap is broken ar missing 1625 03250 real 1 001 8f PN 105785 Panel Pontier 8252 4 TET Hagar 10000 Hold Escape lo cancel Settings Gage Halter bra Pica 10 25 Load eae Cow rae RAD Honec fim E isset boner bergi ian tern iiaa inka o di O atai E E Operator D dob Number 25 100 AT AA 226 RD j Secerty Lre as WXOomnm WO uris m ut perator z 10 w mm mos IBN Gray Ligas Title Guardian Offline Proofing Software User Manual Ref Date June 2011 Issue Release Revision 4 03 9 Add Mask Button If you want to ignore a selected area of print press Add Mask and size it accordingly Click Next 10 11 Step to proceed Position Locate Boxes Left click the three Locate boxes and drag the boxes over areas of text or copy Locate Box General Rules Place locate boxes over the s
17. image Right click to display zoom options Project Saved Master rd1241 1 001 prede e eet Fd wi Th Supplement Facts Se tae ane A TFF hi id M Ia sdi pan k ara Ps amiar T Qu Ap F q um azumon m z EYI a LA rg adas hn r la mma PAL E Parris Erg H mg IF Wi a pris h imus i F A Lad na Im HELIO cs CAPA A En Bar t dc Aer gmu qn o a Fir H I 1 r i E ART p HIE tme 2101 0 Edi erari E m 3 3 Opening an Existing Project This section will give you instructions on how to open an existing project and perform print quality inspection 1 Open Project Select the Open button to load an existing project 12 Title Guardian Offline Proofing Software User Manual Ret Issue Release Date June 2011 Revision 4 03 2 Select Project File A file open dialog box will appear Select the OLP file and click on the Open button QOO de k Computer Local Disk C GuardianOLP Projects Search Projects Organize New folder Y Eon Marne Date modified Type EE Desktop de 21CFRPartl1 2 21 2011 456 PM File folder m Downloads n Data 2 23 2010 10 56 AM File folder 55 Recent Places di Master 2 23 2010 11 39 AM File folder n Reports 2 21 2011 4 56 PM File folder ay Libraries Je Scans 2 23 2010 11 38 AM File folder ES Documents n settings 2 23 2010 10 56 AM File folder a Music n Validation Samples 2 23 201010 56 AM File folder Pictures RD1241 1 olp 2 23 201
18. ing the number around and number across Manual Positionino Across Around No Objects 1 1 Objects Bkg Objects Only 15 Title Guardian Offline Proofing Software User Manual Ret Issue Release Date June 2011 Revision 4 03 11 Adjust Test Box Spacing Optional Click on the Test Box Spacing sliders or enter the spacing in pixels into the text boxes While adjusting the sliders the test box spacing will adjust Manual Positioning Across FAround Add 1 1 Boxes 12 Objects Background Selection buttons Optional These selection buttons are used for selecting inspection parameters It is possible to inspect objects only background only or objects and background Objects and background is the default setting Manual Positioning Across Around San T5 7 No Objects 1 1 235 a Objects Bkg J Objects Only 13 Perform Inspection Click on the Inspect button to perform inspection Save Show 14 Reset Button When the reset button is clicked the operator is allowed to reposition the region of interest boxes before conducting another inspection zr Save Show 15 Save Project Button When the save project button is clicked the project is saved Gave Show 16 Title Guardian Offline Proofing Software User Manual Ret Issue Release Date June 2011 Revision 4 03 16 Overview Window Provides a window to displa
19. n To install the Guardian Offline Proofing Software first uninstall via control panel add remove program previous versions of the Guardian Offline Proofing Software Insert installation disk into CD reader and click on setup exe The setup program will then guide you through the rest of the procedure 2 1 Hardware and Software Requirements Microsoft Windows with Intel or AMD based processor 2 2 How to configure the application Configuration items are not handled in this version 2 3 Cleaning the scanner glass 1 Disconnect the power cord from the scanner 2 Open the scanner lid 3 Clean the glass using a soft lint free cloth that has been moistened with glass cleaner 2 4 Connect Scanner 1 Connect one end of the USB Firewire cable to your computer and connect the other end of the cable to the scanner s USB Firewire port 2 Press the Power button on the front panel of the scanner and wait for the lights to stop blinking and stay on steady The scanner will be detected by your system automatically Title Guardian Offline Proofing Software User Manual Ref Issue Release Date June 2011 Revision 4 03 3 USAGE 3 1 Introduction The Guardian Offline Proofing Software is developed by PC Industries to allow printers to automatically inspect and compare scanned printed images to a PDF or other scanned printed images The software will also provide PDF to PDF comparison Failed inspection Master rd1241 1
20. n inspected Repeat Train Retrains the objects during the inspection process for all regions m Pos Diff Check Algorithm that limits the search area and locates for objects o A Options Objects info 2 Object Min 3 Small Border v Display Objects 2 Object Border 15 Small Object Size Repeat Train 30 Min Contrast Group Objects v Smooth Master 1 Group Distance Ignore Inside Pos Diff Check 26 Title Guardian Offline Proofing Software User Manual Ret Date June 2011 Issue Release Revision 4 03 7T Advanced Information Settings Displays System Information for the OLP and allows for alternate advanced options When making changes to setting re inspection is necessary for the changes to take effect a b Database File When enabled a data base file OLP is used to record all inspection information Default Scanner When unchecked will display a scanner selection dialog box When enabled set the last scanner used as the default scanner Scanner UI When enabled allows access to the Scanners settings dialog box for adjusting settings within the scanner Large Master Displays if current master image is considered a large format image and saves to hard drive Print Label Option When enabled displays a print label button next to the save settings button Clicking on the print label button allows labels to be printed to a label printer Auto Print
21. n the number keyboard will display the master image Result 1 eee 21 Title Guardian Offline Proofing Software User Manual Ref Issue Release Date June 2011 Revision 4 03 3 6 System Settings This section gives instructions on how to adjust the sensitivity and system parameters In order to change system and sensitivity setting it is necessary to log into the OLP system as a manager or administrator There are three levels of security operator manager and administrator Operators have no access to settings Managers have access to sensitivity settings and basic settings Administrators have access to all settings 1 Login Button Click on the Login Button to display the user login popup box Operator ID Job Humber Security Level Operator 2 Login Popup In the Operator ID text box enter in a valid operator name Next enter a valid password for the operator Clicking on the OK button will log the operator into the system Clicking on the cancel button will leave the system with the previous operators settings Operator ID User Name Password 22 Title Guardian Offline Proofing Software User Manual Ret Issue Release Date June 2011 Revision 4 03 3 Sensitivity Settings Allows the sensitivity to be adjusted a Min Defect Size Objects Background in pixels the software will filter and ignore defects blobs smaller than this setting The lower the number increases the
22. nd DPI 400 Min Size Objects 10 Min Size Background 10 Contrast Objects 25 Contrast Background 150 Register Objects 2 Register Background 20 Scan Width 12 scan Height 1 Scan Contrast 0 Scan Brightness 0 Background Sensitivity False Enable False Defect Delete False Resize PerCent 100 ROI Mask Type Rectangle Object Accept 75 Object Border 2 Object Search 30 Object Edge Contrast 30 Max Object Size 500 Min Object Size 4 Min Object Contrast 30 Object Small Border 3 www pcindustries com 6 28 2009 Image Type Color Number Up 9 Number Across 1 Number Around 1 Small Object Size 15 Object Group Distance 4 Object Ignore Inside 1 Object Search Area 150 Object Auto Contrast 1 Background Objects 0 Group Similar Objects 1 Object Contrast Sensitivity O Auto Find Accept 30 X Scaling Enabled 1 Scaling Enabled 1 Max Defect Boxes 500 Max Skew 2 0 Skew Enabled 1 Defect Boxes Enabled 1 Highlight Enabled 1 Group Defects 1 Group Spacing 75 Pages 1 of 2 signature 19 Title Guardian Offline Proofing Software User Manual Ref Date June 2011 Defects Found 4 Critical Defects 4 Defect Information Defect Image Defect 1 Rowd Coli Size 15 Defect Rowd Col 1 Size 32 Reject Defects Rowd Col 1 Size 18 Defect4 Rowd Col 1 Size 2B inspection to chinmontc Www ncindustries com 620 2009 Pages 2 of
23. ngs menu 5 Defect Chart Displays the result of the inspection To move up through the defects click on the move up button or press the number 4 key on the keyboard To reject a defect click on the reject button or press the number 5 key on the keyboard To accept a defect click on the accept button or press the number 6 key on the keyboard Click on the print screen button to print a picture of the screen and click on the PDF report button to Generate a secure PDF report for an inspection 6 PDF Report Click on Create Report or PDF Report depending on which report type was purchased with the system to display the detailed results of the inspection The report is automatically saved to the hard drive and can be printed from directly from the on screen report viewer 18 Title Guardian Offline Proofing Software User Manual Ret Date June 2011 Issue Release Revision 4 03 Sample Report Guardian OLP Certificate of Inspection Result Failed Inspection Date 6 28 2009 Time 9 48 22 AM Job Number Operator john Master Image Master File RD1241 Color Test File RD1241 Color Test1004281215 tif Report File RD1241 Color 090628094822C pdf Software Version v2 36 Test Image Supplement Facts Serving Se 1 Tablet foreland Per Caarsinec 15 ro i Pn ne ry f 143463 07641 Inspection Systems x E rra z I h zrFAR Inspection Type Objects Backgrou
24. on Rotate 90 CCW to rotate the image 90 degrees counter clockwise Rotate COW Rotate 1280 Rotate CVV 14 Title Guardian Offline Proofing Software User Manual Ref Issue Release Date June 2011 Revision 4 03 7 Auto Find Number of Images Enter the number of images within the Scan for inspection and click the Find button The software will automatically find and position as many test boxes as possible Skip to step 11 if all images are found and positioned correctly M cave Show DEN Note If images are displayed with blue X through them after clicking on the find button then image scan was cut off or the scanned image does not match the master image Supplement Facts Serving Se 1 Tablet Beings Por Container 120 af E ar i Vi u ok T uU cnm Ln Lh E FE PE PJDLISTRIES hw prirduszriescorm Only perform steps 8 12 if step 7 didn t successfully Auto Find all of the images 8 Show Advance Position Button Click on the show Advance Position button to manually set the number of images V Savi Show 9 Enter Number of Images Optional Type in the number of images across into Across and the number of images around into Around When this number is changed it will enable the Add Test Boxes button Manual Positioning Across Around 75 Lb 1 No Objects 1 EXE a Objects Bkg j Objects Only 10 Add Test Boxes Optional Click on the Add Test Boxes button after enter
25. one that will happen before a screen is updated n Group Spacing Distance in pixels defects must be within for grouping defect boxes o Locate Search is used for adjusting the size for the locate search area in pixels on a test image Decreasing this number improves the maximum inspection speed Increase this number if inspections fail due to acceptable positional variations on the test image p Locate Accept sets the minimum match value for the locate image acceptance Decrease this number if the inspection fails because of acceptable quality variations on the test image Increase this number to fail unacceptable quality variations on the test image and to prevent incorrectly locating on similar areas of print Typical setting 50 to 85 Options Objects Info J Hi t Auto Find J X Autoscalin ghiigh i 500 Max Defects 2 Update Rate 4 Group Defects 4 Auto Skew 30 Find Accept 75 Group Spacing J DefectBoxes Auto Inspect W Y Autoscaling Locate Boxes 2 Max Skew 50 LocateAccept 150 Locate Search F b S a 25 Title Guardian Offline Proofing Software User Manual Ret Issue Release Date June 2011 Revision 4 03 6 Advanced Object Settings These setting are used to define objects and are only accessible to the system administrator When making changes to setting re inspection is necessary for the changes to take effect a Object Min Filters objects found below this tot
26. st Flatbed D can Contras Flatbed 20 scan Brightness B5 Y 14H Test Box Rectangle 100 Resize Image Round Rect Ellipse 400 d 5 Scan Master Image Optional Click on the Scan Master button after selecting input type at the top of the screen and a dialog box from the scanner should appear indicating the scanner is acquiring the image 6 Rotate Master Image It s recommended that the master image match the orientation of the scanned images The master image can t be rotated after it s trained but the scanned or test image can be rotated before inspecting Click on Rotate 90 CW to rotate the image rotate 90 degrees clockwise click on Rotate 180 to rotate the image 180 degrees and click on Rotate 90 CCW to rotate the image 90 degrees counter clockwise Rotate CCW Rotate 180 Rotate CVV Title Guardian Offline Proofing Software User Manual Ref Issue Release Date June 2011 Revision 4 03 7 Region of Interest Box After scanning or loading a master image a position box will be centered and scaled to the size of the image automatically 8 Position Region of Interest Box Left click the inspection box and drag the mouse until the area to be inspected is highlighted After releasing the mouse the box can be adjusted by left clicking and holding on the edge of the box and moved by clicking and holding in the middle of the box Master Image Loaded Directions Install an inspection system
27. y the current zoom area on the main window Overview Window rd1241testlabel 001 tit 17 Title Guardian Offline Proofing Software User Manual Ret Issue Release Date June 2011 Revision 4 03 17 Review Inspection Results A PC Industries Guardi oOo j A ES eee Sane ME a Failed Inspection Load Scan ave how wat wot Pl na e ee 2m Master RD 1241 Open New Project Project Pixel Position 3653 2824 Sensitivity Settings Min Size Objects Min Size Background Hold Escape to cancel image Displayed Resul 10 ts Contrast Objects Contrast Bagfground Scan Scanner so Object Search 5 130 2 j 20 Scan Brightness 30 Object Edge eon 4 SE Test Box 500 Rectangle V Auto Object Contrast 100 Resize image Round Rect High Object Senstivty Ui vires ae rri lir rims 1 Test Box Location Displays test box location relative to other boxes 2 Test Box Results Displays defect score in pixels If this number is larger than the defect limit the inspection failed due to defects 3 Defect Box Displays blue defect boxes around defects that meet the defect size and contrast settings Copy defects are displayed in red and background defects are displayed in yellow If the mouse is hovered over the defect box the overall defect number and defect size is displayed 4 Zoom Menu Right clicking inside image window will bring up the zoom setti
Download Pdf Manuals
Related Search
Related Contents
製品カタログ(ダイジェスト版) "取扱説明書" Dishwasher User manual of DS-2CC1281P(N) Page 1 Page 2 Page 3 パロネス乗~用3連フロントロータリーモアを お Mode d`emploi Résine de modelage Exakto-Form Copyright © All rights reserved.
Failed to retrieve file