Home

意万仕 UL-P100胶灯说明书(GS认证) - Emaux Water Technology

image

Contents

1. EMLIO9102801 INSTALLATION A Preparatory steps which must be completed by the electrician before light is installed see Figure 1 Oo MIN TO POWER SOURCE FEED PARAFFIN WATER LEVEL 45CM MIN FROM WATER LINE TO TOP OF LENS AL a CONCRETE MUST BE CUT BACK AROUND NICHE TO ALLOW FOR A COMPACT PLASTER SEAL Figure 1 Ensure that the electrical system and its wiring for the pool conform to the requirements of your govenment or your local authorities The installation of the Underwater Light should only be performed by a licensed electrician The junction box or the low voltage transformer for 12 volt Underwater Light model is to be located at least 350cm from the edge of the pool see Figure 1 The junction boxes shall not be installed in zones 0 1 and 2 where permitted for SELV circuits Terminal blocks must meet the IEC60988 2 1 standard having the rated connecting capacity of 1 5mm2 use of screw type terminal at least 25A rated current mounted on junction boxes inside See Figure 0 screw type A C 12 7 terminal lamp Saar Figure 0 The light fixture and all metal parts that are within 350cm of the pool must be properly protected with non ductile materials and that the connections must be waterproof e The mounting bracket must be properly installed so that the top edge of the Underwater Light lens is at least 45cm below the surface of the water in the pool see Figure 1 Consu
2. than 10 seconds fill pool until the pool luminair is completely submerged in the water 12 The flexible cable of this luminaire cannot be replaced if the cord is damaged the luminaire shall be destroyed C Winterizing The luminaire should be left in place for winterization MOUNTING BRACKET DO NOT MOUNT ON DO MOUNT ON X vi CONDUIT REVERSE RADIUS IRREGULAR OR FLAT WALLS WITH NO TIGHTER SURFACE UNEVEN SURFACES SURFACE THAN 6 FT RADIUS AS VIEWED FROM TOP Figure 3 gt and a FORCO NC RETE POOL 7 OPEN LOCK POSITION POSITION Figure 4 gt ang n FORFIBREGLASS POOL PRE FABMODULARPOOL ANDVINYLLINERPOOL 7 OPEN LOCK POSITION POSITION Figure 5
3. lt the local government Building Department to be certain that the pool s electrical system meets all applicable requirements B Perform the following steps after the electrical system requirements are met 1 Locate position on a vertical wall where light is to be installed The top of the light lens must be 45cm below normal water level and maximum depth for luminaire is 2 5m see Figure 1 2 Connect conduit to midst of Mounting Spacer left of Bracket see Figure 2 3 If pool surface is to be plastered you must allow proper concrete cutback for plaster thickness Finish concrete surface must be flush with Mounting Spacer CAUTION Finish area surrounding Mounting Spacer MUST be flat and flush with the face of Mounting Spacer this ensures a snug fit between light and wall see Figure 3 4 After pool surface is finished trim the Conduit 5 Wrap a length of the cord up to a maximum of 3 5mt long on the back of the light assembly 6 Connect cord electrical wires at Junction box through Conduit be careful not to pull the 75mm 80mm of slack cord at the luminair through the conduit when connecting the wires 7 Connect all wires to the corresponding circuit wires in the junction box and feed paraffin 8 Secure the junction box cover in place 9 To check for proper operation turn on main switch or circuit breaker 10 Rotating Locking System ensures light is secured to bracket see Figure 4 11 Before operating the lamp for more
4. ooo M WARNING Never operate this pool lamp for more than 10 seconds unless it is totally submerged in water Without total submersion the lamp assembly will get extremely hot which may result in serious injury to pool users installers or bystanders or in damage to property Be sure power is off before installing or removing lamp Allow lamp to cool before relamping This light fixture uses a Halogen Quartz lamp Do Not touch lamp with bare hand this may severely reduce its life Use the plastic furnished with the replacement lamp to eliminate finger prints pin from the bulb For use only when immersed in water IP68 For operation only with approved safety isolating transformer Input 230V Output 12V 75VA Water Technology The safety isolating transformer must meet the EN61558 2 6 standard SELV the safety source shall be installed outside of Zone 0 1 and 2 If you want to replacement the lamp loosen the screw of back cover open the back cover and replace the lamp and carefully fixed gasket seal re tightening the screw The replacement takes place from the side of the luminaires in contact with the water but after the water of the pool has been partially or completely drained U L P 1 0 0 S U d t L ht CAUTION Never try to repair or replace the lamp by yourself If this underwater light fixture is out of working it shall be e ri es n e rwa e r l g repaired or replaced by the manufacturer or his service agent or similarly qualified person
5. s in order to avoid a hazard t n P d CAUTION The transparent plastic Protective Shield can not be replaced if the Protective Shield is cracked this underwater light fixture shall be scrapped REPLACEMENT PARTS UL P100 Underwater Light Replacement Parts Item Part No Qty Description UL P100 Lights Colour lens Red Green Blue 03011018 M5 20 Screw 01051059 Face Ring 01041021 UL P100 Lights Lens 03021018 M6 Copper Nut 01051058 UL P100 Lights Face plate 02021004 O ring 04011002 Bulb 12v 75w 89040201 UL P100 Lights Body set 03011032 M6 20 Screw 01013004 LED P100 Lights Cable 2 5M 89040203 UL P100 Lights Concrete pool Fitting 89044501 UL P100 Lights Vinyl pool Fitting DANGER RISK OF ELECTRICAL SHOCK OR ELECTROCUTION 01221002 Please read the following carefully and keep this user manual save for future reference OO OINI OD aA AJOJN This underwater light fixture must be installed by a licensed or certified electrician or a qualified serviceman in accordance to the requirements of your government standard or local authorities Improper installation will create electric hazards which could result in serious injury death as well as damage to the property Before servicing the light disconnect the power supply from the circuit breaker Failure to do so could result in serious injury death and or damage to the property Concrete Pool