Home

SK-200 / SK-212 Laser Barcode Scanner User`s Manual

image

Contents

1. Read required Secondary el ser barcode from code 39 required for this item full ASCII table Read lt Set gt barcode to confirm More parameter items to be changed Read lt Enter Exit programming mode gt barcode to save and exit Page 11 SCANNER OPERATION Operating the Scanner The scanner reads barcodes in omni directional scan mode as regular practice It can also operate in single line mode for a better aiming on a specific barcode that is printed on a surface with more than one barcode printed closely Single Line Scan Mode In this mode the scanner can emit a single line pattern for user to selectively scan at a barcode among multiple barcodes on one object It can be achieved simply by pressing one button Press and then release the function button where the indicator LED resides a line pattern appears it allows you to aim at the barcode However for SK 200 212 please first pick the scanner unit up from the stand if the stand is used before pressing function button to enter this mode RIGHT WRONG Ensure the scan line crosses every bar and space of the symbol code as indicated in the right Press the function button to decode and transmit the barcode the good read beeps once For consecutive single line scan present the next barcode and press the function button within 5 seconds When the function button is released it automatically switches back to omni directional scan mode in 5 sec
2. loud beeper cycle every level of setting beeps twice Release the button when you hear the right beeps The scanner beeps accordingly Note The volume setting in this way is not saved in non volatile memory In other words the change will be lost by power off and reset to the configured setting Use the advanced programming guide to set the changes if you wish to keep the changed volume setting LED Indications A dual color red blue LED indicates operating status as follows LED status Indication Off No power supplied to the scanner Steady blue light The scanner is on and ready to scan One red flash A barcode has been successfully decoded Steady red light A barcode has been successfully decoded but the object is not removed from the scan window The scanner is in programming mode Flashing blue light The scanner is in sleep mode Steady red and blue light This indicates the scanner has a motor or laser failure For motor failure a periodic beep is sounded Return the unit for repair Alternate flashing red The scanner detects failing power Please check the and blue light power supply Page 13 Beeper Indications A beeper gives audible feedback on scanner operation Beer Indication One beep A barcode has been successfully decoded Four beeps in series This indicates the scanner passed the power on self test and is operating properly Two beeps low high
3. 1 107 10661030062 Pan Head Screw M3 6L 2 108 52626010034 Omni directional Laser Barcode Scanner 1 Note Items 103 to 106 are preinstalled as a bracket kit Item 108 is delivered with interface cable separate from the main scanner unit If any contents are damaged or missing please contact your dealer immediately Please leave this user s manual within easy access of person using the scanner KIT APPLICATION This kit is applicable to all 15 amp 17 KS amp TP series Page 2 KIT NAME SK 212 KIT CONTENT Besides this guide Fig 2 Kit content besides this guide ITEM PART NUMBER DESCRIPTION Q TY 201 36596005010 WALL MOUNT KIT 1 202 18050103013 TOP SCANNER BRACKET B SK 212 1 203 18050104013 BOTTOM SCANNER BRACKET B SK212 1 204 152626010034 Omnidirec Laser Code Scanner 1 Note If any contents are damaged or missing please contact your dealer immediately Please leave this user s manual within easy access of person using the scanner KIT APPLICATION This kit is applicable to all 12 amp 10 KS terminal amp LM TM series Page 3 INSTALLATION GUIDES FOR SK 200 1 Install the USB interface cable onto the scanner by inserting the 8 pin RJ45 type modular plug Fig 3 of the cable u into the scanner until a firm click is Fig 3 RJ45 Type Modular Plug heard 2 Turn the bracket kit items 103 106 to the rear side and match the 2 screw holes on the b
4. 19 Message Terminator H tab Note The reading of the ABORT label discards all the parameters changed previously However the reading of the Enter Exit of Programming label is still required to exit the programming mode Abort Exit program Page 20 ming mode Return to customer default Note The reading of the label will recover all parameter back to customer default Note The reading of below label allows the current settings to be saved as a customer default Save as customer defaul Page 21 Enable Codabar Disable Page 22 Page 23 Full ASCII CODE39 Enable Full ASCII CODE 39 Disable Page 24 IUPC EAN JAN Enable UPC EAN J Page 25 ITF 2 of 5 ITF 2 OF 5 Disable Page 26 UPC EAN ADD ON OFF ADD ON 5 only Page 27 Il Il Page 28 IEAN UPC Add on none mandatory n mandatory Page 29 EAN UPC Add o Force UPC A to EAN 13 format enable Force UPC A to EAN 13 format disable Page 30 AN 13 Convert to I EAN 13 Convert to ISBN ISSN Disable Page 31 EAN 128 EAN 128 Disable Page 32 Enable Code 128 Disable Page 33 Il Enable Page 34 Chinese Post Code Chinese Post Code Disable Page 35 n Pharm ode Enable Code 32 Italian Pharmacy Code Disable Page 36 MSI enable MSI Disable Page 37 Enter Exit Programming Mode
5. and space saving hands free omni directional laser scanner It can operate in a single line laser scan mode by pressing down a button It is installed upside down in SK 200 212 Featured with Z scan hardware decode technology it guarantees the real time decode and provide the best scanning performance you could expect The scanner includes key features as e Button switch in between omni directional and single line scanning capability ideal for increasing your operating efficiency e Powerful 20 line scan pattern yields v 1400 scans per second for omni directional scanning v 74 scans per second for single line scanning Implement with the proprietary real time hardware decoding technology that ensures instant recognition and decoding barcodes Parts Identification Each part of the scanner as indicated in the front and rear pictures below are described in the table below Please note that the scanner unit is installed upside down on SK 200 212 bracket Function Button Scan Window Mounting Screw Hole gt Object Detector u io Beeper Hole Interface Cable Connector Description Function Scan Window Reads barcodes Object Detector Trigger and wake up scanner automatically when presented with barcode in its range Beeper Hole For beep tone indication Page 8 Function Button Embedded with the LED Indicator Wake up scanner When the scanner enters the sleep mode pressing this sw
6. mode gt lt RESET gt lt Return to USB default gt or lt Return to customer default gt if a customer preference has been saved previously and lt Enter Exit programming mode gt consecutively Set Up When the scanner is powered on LED blue present the lt Enter Exit programming mode gt barcode found in the Programming Codes section to the scanner The scanner gives two beeps low and high and the LED turns red The scanner enters programming mode Decide which parameters are required and find their barcodes in the programming codes section Page 10 Cover unwanted codes with your hand and present the desired codes one by one to the scanner the scanner beeps once as it accepts each code When done again present the lt Enter Exit programming mode gt barcode The scanner beeps twice once long and once short and the LED returns to blue The scanner has been programmed Of course you may also read the lt Abort gt to exit the programming mode if the changes made are not desired Test again with known good barcodes If results are good you are done setting up Otherwise return to step 1 and try again A demonstrative process flow chart is given below to illustrate the whole setup process Read lt Enter Exit programming mode gt barcode to start configuration Change scanner setting by scanning required mode barcode Display Firmware Version Send firmware version to host system and save and exit
7. peak output up to 0 8mW would be accessible inside Laser Light Viewing The scan window is the only aperture through which laser light may be observed from this product A failure of the scanner motor while the laser diode continues to emit a laser beam may cause emission levels to exceed those for safe operation The scanner has safeguards to prevent this occurrence If however a stationary laser beam is emitted the failing scanner should be disconnected from its power source immediately Adjustments Do not attempt any adjustments or alteration of this product Do not remove the protective housing of the scanner There are no user serviceable parts inside Caution Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure Optical The use of optical instruments with this product will increase the eye hazard Optical instruments include binoculars magnifying glasses and microscopes but do not include normal eye glasses worn by the user Warranty Limits Warranty terminates automatically when any person other than the authorized technicians opens the machine The user should consult his her dealer for the problem happened Warranty voids if the user does not follow the instructions in application of this merchandise The manufacturer is by no means responsible for any damage or hazard caused by improper application No part of this document may be reproduced t
8. the scanner If troubles occur please refer to the following diagnostic tips as a mean to solve the trouble However before referring to the tips make sure that the scanner is installed as instructed in this manual and that all cables are properly connected If the problem remains contact your dealer Page 14 Problem The scanner is on but cannot read barcodes Diagnostic Tips The scanner window is dirty Clean the scanner window as described in the Maintenance section The LED stays blue The presented barcode type is not enabled Use the Programming Guide to tell the scanner to accept that type of barcode The host has disabled the scanner Check host setup The barcode type presented is not supported by the scanner The scanner is on but the motor is not running the facet wheel is not rotating A barcode cannot be read The LED is intermittently flashing blue The scanner has entered into the sleep mode Press the function button to wake up the scanner or present an object close to the scan window The LED remains red and blue purple Possible failure of the scanning safeguard circuit Disconnect the scanner from its power source immediately and contact your dealer The scanner does not accept more than two or three bar code labels There is no proper handshaking with the POS system Check connection and communication settings of the host POS system A stray barcode is sitt
9. will look like the rightmost picture in Fig 5 below B Matching Holes Screw Holes r Fig 5 Fix to Wall 5 Loosen the 2 slide adjust screws item 105 arrowed in Fig 6 at right by turning counterclockwise for a quarter to half turns to lower the slide bracket with scanner Then hang the main unit of a KS or TP series touch terminal or touch monitor on to the bracket align the four matching pegs on the back of the main unit to the four matching holes in the bracket marked by rectangles in the picture allow the main unit to go down the guide by gravity push it to the left and allow it to seat in the lowest corner of the matching holes 6 As a remark for future removal of the main unit from the bracket please remember to raise the main unit move it to the right and further raise it up to allow matching pegs to Fig 6 To Join the Main Unit come out of the matching holes 7 Connect the USB cable to an USB port of the main unit Do all necessary connections for the main unit Replace the cable cover and keep the excessive part of the cable inside the cable cover as much as possible Then slide the slide bracket up to proper position required for use Tighten the 2 slide adjust screw The front view of the scanner will look like Fig 7 at right Peel off the protective film on scanner for ready to use after all the operations done Fig 7 Mounted Page 5 FOR SK 212 1 Install the USB interface cable onto the
10. PUSIFLEX SK 200 SK 212 Laser Barcode Scanner User s Manual Rev AO FCC Notes This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual may cause interference to radio communications It has been tested and found to comply with limits for a Class A digital device pursuant to EN55022 and 47 CFR Part 2 and subpart J of Part 15 of FCC Rules which are designed to provide reasonable protection against interference when operated in a commercial environment Operation of this equipment in a residential area is likely to cause interference in which case the user at his own expense will be required to take whatever measures to correct the interference For CE countries This scanner is in conformity with CE standards Please note that an approved CE marked power supply unit should be used in order to maintain CE conformance Laser Safety The laser scanner complies with safety standard IEC 60825 1 for a Class I laser produce It also complies with CDRH as applicable to a Class Ia laser product Avoid long term staring into direct laser light Radiant Energy The laser scanner uses one low power visible laser diodes operating at 650nm in an opto mechanical scanner resulting in less than 3 9uW radiated power as observed through a 7mm aperture and averaged over 10 seconds Do not attempt to remove the protective housing of the scanner as unscanned laser light with a
11. Page 38 Drill at center of dashed cross THIS SIDE UP Use drill tip of diameter 1 4 or 6 25 mm Each hole should be at least 1 3 8 or 35 mm deep Drill at center of dashed cross LA Y Template for WB 6812 Drilbateenter of dashed cross Page 39 Drill Pattern Template I FR CI Jp Drill at center of Hp h o Ny od N F Ai Drill at lt center of t THIS SIDE UP Use drill tip of diameter 1 4 or 6 25 mm Each hole should be at least 1 3 8 or 35 mm deep 6 77 or 172 Drillat 1 LE Drill at center of 3 82 or 97 a S ZTN vs N j center of arr a Page 40
12. The scanner has entered programming mode Two beeps same tone Scanner has returned from programming to normal mode Continuous tone This is a failure indication Return the unit for repair SCANNER MAINTANTENCE Maintaining the Scanner The scanner is designed for long term trouble free operation and rarely requires any maintenance Only an occasional cleaning of the scanner window is necessary in order to remove dirt and fingerprints Cleaning the Scan Window Wipe the scan window with a soft lint free cloth and a non abrasive cleaner to avoid scratching and damaging the scan window The scan window may be cleaned while the scanner is running Replacing Interface Cable The standard interface cable is attached to the scanner with an 10 pin modular connector When the connector is properly seated it is secured in the scanner by a flexible retention tab The cable is designed to be field replaceable Replacement cables can be obtained from your authorized distributor To replace the cable take the following steps Make sure the power of both host computer and the scanner is switched off Disconnect the old scanner cable from the computer system Press down the retention tab and gently pull out the cable Insert the new interface cable into the bottom of the scanner until it clicks Plug the new cable into the host TROUBLE SHOOTING GUIDE This section contains information about how to solve problems that you may encounter when operating
13. ack of the Laser scanner item 108 with the Laser scanner itself upside down Apply the 2 screws item 107 to join them as arrowed in the right picture Fig 4 3 Select a flat surface on wall of adequate strength and with proper ventilation and space condition Please use the right material to hold the whole kit according to the wall material Drywall concrete solid wood etc Consult with your contractor if it is necessary A fully equipped system supported on the bracket may weigh up to 11 kg or 23 lbs Unfold the paper template attached to last page of this manual and cut it down along the guide line to work as guide for drill pattern on the wall surface in correct orientation Drill 4 holes in rectangular layout as marked in the template that gives a rectangular drill pattern of 6 77 or 172 mm wide horizontal and 3 82 or 97 mm high vertical Hole diameter should be 1 4 or 6 35 mm each Hole depth should be at least 1 and 3 8 or 35 mm Please then insert one plastic cotter item 101 into each hole leaving the flat end with hole of the plastic cotter at the outside opening of the hole Use a hammer to tap the plastic cotter in gently if necessary Fig 4 Fix the Scanner Page 4 4 Remove the template and hold the bracket against the wall Make sure that the wider part of each of the four matching holes faces in the upward direction Screw item 102 at screw holes through matching holes into plastic cotters The result
14. er able to detect automatically the most commonly applied bar code types as tabulated above and send the data to the host system as if they are read from an USB keyboard To read the disabled bar code types the programming barcodes enclosed in the later sections of this booklet are required to enable the required bar code type There are other advanced features like beep tone sleep mode timings same code delay time setting headers and trailers for data output and setting some particular parameters within each code type or even some legacy settings like the communication interface type actually only USB is applicable in SK 200 212 can be achieved by downloading the advanced programming bar codes from our web site and scanning the printed programming codes Individual parameters may be set at any time without affecting the other parameters Scan Test With the scanner running LED blue and the host system on with an active window of a text editor try to scan several known good barcodes Check the results on the system screen If the scanner is reading okay no further setup may be necessary If the POS screen does not show the expected scans go to Set Up below Reset to Default Status Since there is a legacy feature in scanner firmware development history to support other interface than USB which is the only applicable interface for SK 200 212 when you want to reset the scanner to default status please scan lt Enter Exit programming
15. ht to alter product designs layouts or drivers without notification The system integrator shall provide applicative notices and arrangement for special options utilizing this product The user may find the most up to date information of the hardware from http www posiflex com or http www posiflex com tw or http www posiflexusa com All data should be backed up prior to the installation of any drive unit or storage peripheral Posiflex Technology Inc will not be responsible for any loss of data resulting from the use disuse or misuse of this or any other Posiflex product All rights are strictly reserved No part of this documentation may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying or otherwise without prior express written consent from Posiflex Technology Inc the publisher of this documentation Copyright Posiflex Technology Inc 2010 All brand and product names and trademarks are the property of their respective holders P N 18050900040 Page 1 PRODUCT INFORMATION KIT NAME SK 200 KIT CONTENT Besides this guide Fig 1 Kit content besides this guide ITEM PART NUMBER DESCRIPTION Q TY 101 110241000021 Plastic Cotter 4 102 10641040162 Self Tapping Screw 46 16L 4 103 16200123053 Wall Mount Bracket 1 104 18050101013 Fix Bracket 1 105 10684038083 Slide Adjust Screw 6 32 8L 2 106 18050100013 Slide Bracket
16. ing somewhere in the scanner field of view Remove all barcode labels from the scanner s scan volume and try again The scanner cannot send the data to the POS system Make sure that all cables are connected and your host POS system is ready to receive data A barcode is read by the scanner but not accepted by the POS system The communication settings of the system and scanner do not match Adjust the settings so they match The communication cable used is incorrect Contact your dealer for the correct communication cable The software running on the POS system does not support the data format of the barcode label Page 15 PROGRAMMING CODES All framed barcode names represent as default settings Enter Exit Programming Mode Note This code to enter and exit programming mode is also printed on the last page of this section for ease of application Note The reading of the Display Firmware Version label will show firmware version and exit the programming mode Display Firmware Version Page 16 Note The reading of the RESET label turns all the parameters back to default values but leaving the interface mode unchanged It is suggested to scan also the Return to USB default label after this for SK 200 212 scanners Return to USB default Page 17 US Keyboard International Keyboard ALT m Page 18 Message Terminator Enter ssage terminator Non Page
17. itch can wake the scanner up The sleep mode feature can be programmed using the menu labels from the Programming Guide NOTE The default time out value is set to 10 minutes after laser slept 30 minutes after motor slept When the scanner is in sleep mode the LED inside function button is intermittently flashing Blue Single line mode Press and release the button will activate single line scan mode Mounting Screw Holes To fix the scanner onto the bracket of SK 200 212 kit Interface Cable Connector For USB interface cable connection Operation Status When the scanner powers up the buzzer gives four beeps and the LED indicator in function button glows Present a known good test barcode to the scanner The scanner should issue a short beep and the LED should flash red momentarily Note Refer to LED Indications and Beeper Indications sections in later part of this booklet for operation status or refer to the section on Troubleshooting Guide for diagnostic tips Supported Bar Code Types UPC EAN JAN Enabled ITF 2 of 5 Disabled Code 39 Enabled Codabar Disabled Chinese Post Code Disabled MSI PLESSY Disabled Code 93 Disabled Code 128 Disabled Code 32 Italian Pharmacode Disabled ISSN ISBN Disabled EAN 128 Disabled Page 9 SCANNER SETUP PROGRAMMING In most of the cases no setup is required The default setup of the scanner makes the scann
18. luding in the Wall Mount Kit at screw holes through matching holes into plastic cotters The result will look like the following picture in Fig 9 below Fig 9 Fix to Wall Page 6 Loosen the 2 slide adjust screws which are arrowed in Fig 10 at right by turning counterclockwise for a quarter to half turns to slide the bracket with scanner upper or lower Tighten the 2 slide adjust screw right after the adjustment Then hang the main unit of a KS or LM TM series on to the bracket align the four matching pegs on the back of the main unit to the four matching holes in the bracket marked by rectangles in the picture allow the main unit to go down A the guide by gravity push it to the left and allow it to seat in the lowest corner of the matching holes un As a remark for future removal of the main Fig 10 To Join the Main Unit unit from the bracket please remember to raise the main unit move it to the right and further raise it up to allow matching pegs to come out of the matching holes Connect the USB cable to an USB port of the main unit Do all necessary connections for the main unit Then slide the slide bracket up to proper position required for use The front view of the scanner will look like Fig 11 at right Peel off the protective film on scanner for ready to use after all the operations done Fig 11 Mounted Page 7 USING THE SCANNER SCANNER INTRODUCTION Features The scanner unit is a compact
19. onds Press the button again to switch to single line scan when necessary Omni Directional Scan Mode The scanner will always stay active in Omni Directional Scan mode in normal operation In other words the scanner will always emit multiple scan lines for the convenience in reading a barcode To have successful barcode reading in this mode the barcode must be presented in the way that there is at least one of the scan lines crosses every bar and space of the symbol code as indicated in the right Sleep Mode After the scanner has been inactive for a period of time the laser automatically turns off then the motor will turn off and the scanner will enter the Sleep Mode the blue status LED keeps blinking as indication To wake up the scanner simply Page 12 present an object close to the exit window or press the function button Note The scanner includes a motion sensor that detects activity in front of the scan window The detecting distance is up to about 15cm 6 inches from the scan window Change Beeper Volumn Using Function Button The beep tone volume and duration are programmable by advanced programming codes And the beep volume is adjustable by pressing the function button The volume has 3 different levels low medium loud follow the following steps to tune the volume Always keep the scanner operating Press and hold down the function button for about 3 seconds the scanner will enter medium low
20. ransmitted stored in a retrieval system transcribed or translated into any language or computer language in any form or by any means electronic mechanical magnetic optical chemical manual or otherwise without express written consent and authorization We reserve the right to make changes in product design without reservation and without notification The material in this guide is for information only and is subject to change without notice All trademarks mentioned herein registered or otherwise are the properties of their various respective owners About This Manual Posiflex Technology Inc has made every effort for the accuracy of the content in this manual However Posiflex Technology Inc will assume no liability for any technical inaccuracies or editorial or other errors or omissions contained herein nor for direct indirect incidental consequential or otherwise damages including without limitation loss of data or profits resulting from furnishing performance or use of this material This information is provided as is and Posiflex Technology Inc expressly disclaims any warranties expressed implied or statutory including without limitation implied warranties of merchantability or fitness for particular purpose good title and against infringement The information in this manual contains only essential hardware concerns for general user and is subject to change without notice Posiflex Technology Inc reserves the rig
21. scanner by inserting the 8 pin RJ45 type modular plug as the first step of SK 200 until a firm click is heard 2 Turn the bracket kit items 201 203 to the rear side and match the 2 screw holes on the back of the Laser scanner item 204 with the Laser scanner itself upside down Apply the 2 screws included in the kit s content to join them as arrowed in the right picture Fig 8 3 Select a flat surface on wall of adequate strength and with proper ventilation and space condition Please use the right material to hold the whole kit according to the wall material Drywall concrete solid wood etc Consult with your contractor if it is necessary Unfold the paper template attached to last page of this manual and cut it down along the guide line to work as guide for drill pattern on the wall surface in correct orientation Drill 4 holes in rectangular layout as marked in the template that gives a rectangular drill pattern of 5 75 or 146 mm wide horizontal and 2 95 or 75 mm high vertical Please then insert one plastic cotter including in the Wall Mount Kit into each hole leaving the flat end with hole of the plastic cotter at the outside opening of the hole Use a hammer to tap the plastic cotter in gently if necessary Fig 8 Fix the Scanner 4 Remove the template and hold the bracket against the wall Make sure that the wider part of each of the four matching holes faces in the upward direction Self Tapping Screw inc

Download Pdf Manuals

image

Related Search

Related Contents

Prima impostazione e messa in funzione  TopSURV Reference Manual - Levantamientos-especiales  Zanussi FLS 1383 W Instruction Booklet    Troubleshooting  給付金請求書 兼 医療照会同意書  INSTALLATION MANUAL MANUEL D`INSTALLATION  PG Interface Card "OPC-G1-PG"  

Copyright © All rights reserved.
Failed to retrieve file