Home
TGE-0001
Contents
1. Ltd operates a Business Management System which conforms to ISO 9001 and ISO 14001 EMC EN 61326 1 Electrical equipment for measurement control and laboratory use EMC requirements Safety EN 61010 1 2010 IEC 61010 1 Third Edition 2010 and IEC 61010 2 030 2010 First Edition Safety requirements for electrical equipment for measurement control and laboratory use CE Gemini DATA LOGGERS Issue 5 19th December 2014 E amp OE
2. 0 5A above 10A 0 5 of reading 2 of reading lt 0 02 error above 1kW Temperature Stability of Current Accuracy 0 1 C from 25 C Sampling Frequency 5kHz burst of samples every 2 seconds every 5 seconds when logging on battery power Coils Absolute Maximum Current 5kA AC RMS Logging Specification Logging Interval Reading Capacity 30 seconds to 10 days Six weeks at the default 5 minute logging interval Battery Information Battery Type 4 x 1 5V AA alkaline batteries supplied Battery Life 60 days typical based on a battery capacity of 2500mAH When a mains lead is plugged in the logger will be mains powered If the mains should fail the batteries in the logger will typically keep it recording for 60 days www tinytag info sales tinytag info Tinytag Physical Specification 195mm ao 50mm 102mm This logger is suitable for indoor use only Operational Temperature Range 0 to 50 C Maximum Humidity 95 non condensing Case Dimensions Length 195mm Width 102mm Depth 50mm Weight Including batteries 600g Coil Dimensions Coil Thickness 8mm Inner Loop Diameter 85mm typical Cable Length 1m Weight 729 PC Connection USB Approvals Gemini Data Loggers UK
3. TGE 0001 Tinytag Energy Logger Kit Ai AN FA 7 KK Rey YN iS RX A s4 oe D TA P V a SY T MAD A The Tinytag Energy Logger can be used to monitor single and three phase energy supplies combines the level of performance required by experts with the level of simplicity required by those that are new to energy management The unit is ideal for monitoring building energy supply sections within a building or individual pieces of equipment Data from the Tinytag Energy Logger can be used to identify power hungry or inefficient equipment and peak load times and can highlight equipment that is left powered up or idling unnecessarily The Tinytag Energy Logger provides visibility of energy usage so that effective measures can be taken to reduce electricity bills lower carbon footprint and improve environmental performance Features Popular Applications e Simple to use e Before and after equipment installation monitoring e High accuracy e Equipment troubleshooting e Non invasive e Long term energy usage e Small size lightweight e Equipment spot checks e Standard coils 85mm internal diameter typical e Meeting ISO 14001 energy reduction targets www tinytag info G eC mM I nN sales tinytag info DATA LOGGERS Issue 5 19th December 2014 E amp OE TGE 0001 Tinytag Energy Logger Kit Benefits e Portable supplied in its own carry case the unit is small and lightweight making it
4. ideal for use in on site visits e Easy to use select the required wiring configuration and the logger will display step by step instructions for the coil and cable connections e Quick and easy coil fitting current is measured using non invasive flexible coils that can easily be clipped around conductors where larger rigid clamps may not fit and the voltage reading is taken from a standard mains cable e Self configuring once connected the unit will self configure and current voltage power and power factor readings will be displayed e No complicated set up procedures current coils do not have to be connected in the direction of the current flow and coils do not have to be matched to specific sockets The coils supplied can loop around conductors up to 85mm in diameter www tinytag info sales tinytag info e Spot checks or long term monitoring the unit can be used for spot checks or for longer term monitoring to build up energy usage profiles e Onsite PC not necessary logging is started at the press of a button no computer is required to start the data logger Recording can be started and stopped multiple times to allow different pieces of equipment to be monitored in one visit Separate files are created for each logging run ready for viewing in Tinytag Explorer e Simple download display and management of data data is viewed and managed using the intuitive Tinytag Explorer software and data can be ea
5. sily exported to spreadsheet programmes such as Excel For profiling buildings data can be combined with temperature and relative humidity data from other loggers in the Tinytag range e Hanging option there is a magnet fitted to the back of the logger so it can be attached to metal panels whilst in use Issue 5 19th December 2014 E amp OE TGE O00 Tinytag Energy Logger Kit What Does the Logger Record Property Logger Display Tinytag Explorer Software RMS Current A Instantaneous Per phase Peak over logging interval Average over logging interval RMS Voltage V Instantaneous Single Single Power kW Instantaneous Overall Peak over logging interval Overall amp per phase Average over logging interval Overall amp per phase e Display the unit s display shows instantaneous rms e High Accuracy the logger samples a 5kHz burst of current A from all three phases the instantaneous data every few seconds building up an accurate rms voltage V and an instantaneous overall power profile of the waveform This makes the unit very figure kW good at accurately reading inductive and complex loads where the waveform may not be a true sine e Automatic software calculations when data is wave downloaded in the Tinytag Explorer software the following information is calculated and displayed e Logging when logging three phase current and voltage the unit will record six weeks of data at the e peak and a
6. verage current default five minute logging interval this can be e peak and average power changed to anything from 30 seconds to once every e overall peak and average power 10 days using the Tinytag Explorer software e energy usage information kWh Saa e a power factor for each phase e Battery power option when monitoring with the voltage connected the unit will power itself from the e Automatic waveform detection the voltage mains When logging current without the voltage connected the unit can record for two months using reference records the waveform of one of the phases four user replaceable AA batteries and this is used as a reference for the other two www tinytag info ini sales tinytag info G emini Issue 5 19th December 2014 E amp OE TGE 0001 Tinytag Energy Logger Kit In the Box The Tinytag Energy logger is supplied in a carry case This case contains the following items 1 x Tinytag Energy Logger 3 x Clip on coils 1 x UK mains lead 1 x EU mains lead 1 x Tinytag Explorer software CD 1 x USB cable 1 x User Manual Measurement Specification Range Current Voltage Frequency Display Resolution Current Voltage Power Accuracy Current RMS Voltage RMS Power kW Power Factor 2 000A AC RMS Momentary peak surge current 2x rated range 200 253V AC nominal Nominal 50 60Hz 0 1A 0 1V 0 1 or 0 01kW depending on the size of the load being measured 1 of reading
Download Pdf Manuals
Related Search
TGE 0001 tg0001 the 1001 the 1001 nights the 1001 lighter the 1001 critical days foundation the 1001 seasons of elie saab the 1001 girls the 1001 jeux the 1001 genomes consortium the 1001 critical days the 1001 apartments the 1001 arabian nights the 1001 apartments omaha the 1001 club the 1001 days
Related Contents
Guía de configuración de Android TV™ Cellecta User Manual, Cloning of shRNA Templates into 「ビジュアレイ-P2」の付属品 OWL500 - WirelessGuys メンテナンス プラス契約約款(2014年4月1日制定) P601 PP Stepping Servo Motor Single Ai xx Programmable MobilAlarm Quick User Guide MobilAlarm Kurzanleitung Télécharger - Bienvenue sur le site des Thèses d`exercice Copyright © All rights reserved.