Home
Power Xpert 4000/6000/8000 Power Quality Meters
Contents
1. ATeN Powerware Quality Meters Power Apert Meter Next Generation Power Quality Meter You can t manage what you can t Power Xpert 4000 6000 8000 ECsM measure and you certainly Meters represent a new genre Product can t measure something of power quality instruments and OF THE you can t even see without a comprehensive world class UeCaAr power quality instrument that is power measurement and 0 Invisible and fleeting power monitoring that reduce Category Winner a 7 disturbances can be silent killers day to day operating costs the electronic equivalent of and help avoid costly high blood pressure Eaton s business interruptions Power Xpert so you dont have to be one EATON CORPORATION Power Xpert 4000 6000 8000 Power Quality Meters 3 Next Generation Power Quality Monitoring and Managementis Now as Easy as Surfing to it with Your Web Browser or Twist and Click on the LCD Display Communications LED Events LED 320 x 240 PixehBacklit LCD Graphic Display Back Button Communicatio 100F amp 10 10 e Modbus IC e Web se Configuration Display gt E m and Modbus Card rP E m i f A r a u L ET un Er j i u gt A i a da i i sy 1 x 7 j x Fare r dela Talko EDIEN Power Input Ethernet RJ45 N Configuration Port Display Measurements e Height 9 00 inches 229 mm e Width 780 inches 198 m
2. 12 x x and higher only vantage point to review and compare multiple events at an unprecedented resolution firmware v 12 x x and higher only IE PM Gap Di Foo al Xpert rg Event Zn ah Mi i September 04 2007 10 13 26 122 AM 0400 Events Ti line Events Timeline Bik Yanl 7 ey piii E Scns Cyle Debs lu ae wii Fitter Legend eo Aa Lieis LiDu ai ame Wien Bree a Demand Oveioad CECI War Baia z a PPE amu MEC Sapta meat yie Devin eee ange ed P ei Cut of Links Seely bee sa Cy ie Dre Bar a Frigg wid Transieni a Ver O ee a ITC SagfSeed hia ai i es Vien een p Update Bias of Lime lan F rs THF 5 fT WRF amp Demani Cheertoad Sub Ctl uba Pan 4 a Zoom Page i of 3 E ign type PSP ese hippa ven ae Thee shen FR Vyas AO Aa Witt ee Pat wien ADL rer er onay r EATON CORPORATION Power Xpert 4000 6000 8000 Power Quality Meters Energy Usage Comparison Screen FTP Energy Directory Energy usage patterns can be effortlessiy analyzed with the Power Xpert Meters save energy consumption measurements in month to month week to week comparison chart Raw data can monthly logs stored on the meter s FTP server Logs can be easily be easily exported with the Save Table option to other applications read copied or imported into third party applications for detailed such as Excel for further analysis or graphing firmware v 12 x x energy usage patterns analy
3. Compl quality information on a charts and gauges Power Xpert Time Stamp Device Type Icon F Faton Cutler Hammer Power Kpert Microsoft Internet Explorer Fe dt Yew Fgvortes Joos Help eu 2 Favorites 2 Picture of 3D Function ae Device Button Bar eS ete 10 2 Event LED 3D Mercury Filled Voltage Current Frequency Power i Power Quality Index Drop Down Factor Gauges u unse A z z ia r Menu for Lead LAN Meter Selection canon al Hose N i 3D PQ 1 u N 1A 18 Ic IN 1G PF Health Index oi g 5 i 4 2 3 80 A G z he u ointing to Exact 59 99 Hz 0209 5V 120 00 1421A 1389A 14 104 0 70 A 0 00 A 0 99 Lead Thermometer Peak Point Latesi G 10 Min auge Me Power i 3 i p 18 24 Latest 24 Hra CED CED Average VLL 209 7 5 10 kVA Peak Measurement Kuba Aut a Tas ki Parameters Frequency 59 99 Hz 1 58 kvar Quality 5 19 4 1 38 o oo cee oe mn 3D LEDs for SDD Curren AE THIT iii ps er a P K Factor 16 81 PQ Temperature Underlined Present Waveform 37282 kWh C Facio 1 59 Web Links Ais ER at sae Saar raiya esenti ee RR Upgrade to Series 6000 Button to 15 Eventis Setup Triggers Sa a Upgrade to the Hare ceti eal rel Hear View and crente Der Ei he zta Power Xpert 6000 nol been chaa ed mor riggers BE Active Setup Met er U nacknowledged 1 04 Jan OR 08 14 48 400 Oui of Limits Piotal OOL High Configure anal commission 04 Jan OE 05 1
4. 5 Communication Expansion Card 8 CompactFlash Card Meter 6 1 0 Card 9 Mounting Brackets Available Accessories Graphic Display Module Power Xpert Meter Triggers and events can be easily tied into the meter s standard functions such as e mail logs and trends The graphic display module provides an at a glance view of power quality with intuitive visual displays statistically derived trending and red yellow green indicators of overall AUX Voltage Input Channels power health In addition it has The optional Voltage Auxiliary a RJ 45 Ethernet port built right VAUX option provides three into the faceplate for easy and voltage input channels V6 V7 safe meter configuration V8 in addition to the standard 4 channels already built in Communication Expansion Card CompactFlash Card An optional communication A CompactFlash memory expansion card supports remote card provides 1 GB of communications with the onboard memory to store onboard Web server application high resolution captured over your LAN WAN or the waveforms along with all the Internet via standard Ethernet data logging associated with 10 100Base T and fiber optic standard monitoring functions connection Modbus is supported over TCP RS 485 Mounting Options RTU and RS 232 ASCII ports e Back to back mount 1 O Card e Q Analyzer retrofit mount The Power Xpert I O Card e Reduced LCD display mount is extremely flexible and can be used in a large variety of di
5. Eh em i Pe ge OE Cores i om 17 12 UPAJA i giai iim BE M a OF Pah WE H 2 Zu Ei Gr re Ye Bi Re BF AFTER TEE Ku Pe Dr Pe ia iD ET a Ei Feb EP EPIIE ee Biia OF LT ee y Bpa DP PS y 5 Phase A Dinpier in Power Factor A u um 1 Wen gt m t February fT Dt OTT PM ae u ne We February 27 S887 PETE FM ee u m l i ol i oe Ba La ee FEULEN Ve a eee Pe Vi ek tte Coe Tee Ba b Be Whee haa EATON CORPORATION Power Xpert 4000 6000 8000 Power Ouality Meters 5 Power Xpert Meter Innovative Intuitive Accurate Accessible The meters combine state of the art technology with next generation ITIC diagnostics waveform capture data trending and performance benchmarking along with a Twist and Click graphic display a new paradigm for simplicity and ease of use in the marketplace The embedded Web server enables users to surf to the meter over the Internet via a standard Web browser The new platform offers advanced functionality like high speed impulsive transient capture 6 MHz sampling rate 100 000 samples per cycle anti aliasing ITIC analysis and automatic trigger setting field upgradeable firmware memory expandable to 1 GB and optional digital relay and solid state O Applications Identify Power Quality Problems e identify harmonics sags swells and transients damaging or disrupting sensitive mission critical
6. Xpert Architecture allows the users to build on their existing infrastruc ture and the flexibility to upgrade as their needs grow going forward Configuration of the meters is simple and easy through the Web based GUI and or the LCD display Display Link RS 485 Up to 16 meters can be daisy chained to a single Power Xpert LCD display Conveniently and cost efficiently a single Power Xpert LCD display can support up to 16 Power Xpert Meter modules This is especially handy when several meter modules are installed in multiple rack or switchgear lineup formations Display Link RS 485 Modbus RTU RS 485 Non Web Enabled A Modbus RTU Master is supported in addition to the Power Xpert LCD display sub network Power Xpert Meters are set up as Modbus slaves This configuration is a cost efficient way to connect to an existing Modbus RTU Master e g a building management system BMS Modbus RTU Master g Connections Ehe isplay link ASS dba ATU R5855 Modbus Slave Network Modbus RTU LCD Display Sub Network Web Enabled Browser amp Modbus TCP Web browsing and Modbus TCP Master connectivity have been added in this configuration example Only one Power Xpert Meter has an Ethernet connection All other Power Xpert Meter modules are utilizing this same connection NOTE Certain restrictions pertaining to waveforms e mail sending and other capabilities apply to the meters using
7. a better understanding of your electrical load versus time Event logging E E Log events for retrospective event analysis Memory amp Storage 512 MB standard memory a a O Store large amounts of waveform captures and events for historical analysis 1 GB optional memory Bl a a Store massive amounts of waveform captures and events for historical analysis Harmonics Harmonic levels ae 127 Provides extremely fast high resolution D A conversion Total Harmonic Distortion THD Review the total harmonic distortion level directly on the meter Delta Sigma D A conversion technology Harmonics over sampling 1 024 samples per cycle Provides extremely fast high resolution D A conversion Over sampling enables the usage of Anti Aliasing technology increasing accuracy Anti alias filtering Individual harmonics Total Demand Distortion TDD Technology to remove out of band signal components resulting in more accurate data Review individual harmonic levels directly on the meter Identify harmful harmonics in e g lightly loaded variable speed drive environments where THD may be high but not relative Interharmonics MO Review interharmonic levels on the meter Highlights Sub cycle disturbance capturing E E m Capture fast voltage changes low frequency transient e g capacitor switching transient dV dt triggers for sub cycle oscillatory transients Ei a E Detect and record a large magnitude
8. set to remind you and achieve your savings goals E e EALL a e HE e the green grid 8 E un member minimizing environmental and economic impacts associated with excessive energy use The use of on site renewable energy will require a means to measure the percentage of building energy requirements The Power Xpert Meter can meter and provide the backbone of load control measurement and monitoring for on site power sources When applying renewable energy every effort should be made to take advantage of net metering with the local utility EATON CORPORATION Power Xpert 4000 6000 8000 Power Quality Meters 19 Eaton Corporation is a diversified industrial manufacturer ranked among the largest Fortune 500 companies The electrical group is Eaton largest division and is a global leader in electrical control power distribution power quality automation and monitoring products and services Eaton s electrical products include brands such as Cutler Hammer MGE Office Protection Systems Powerware Holec and MEM Eaton provides PowerChain Management solutions to serve the needs of the industrial institutional IT data center mission critical utility residential and OEM markets worldwide PowerChain Management solutions help enterprises achieve sustainable and competitive advantages through proactive management of the power system as a strategic integrated asset throughout its life cycle With
9. speeds of six samples every millionth of a second if necessary Easy to Use Interface Demystifies Power Quality In designing these power quality instruments Eaton set out to demystify power quality to take highly specialized data and convert It into useful information that doesn t require a power guru or consultant to understand The result is an uncommonly easy to use interface and new graphical analysis of complex power quality data delivered via e mail over the Web and to third party applications With these capabilities your power team can predict and prevent power quality problems before they lead to equipment malfunction overheated circuits and system failure One Gigabyte of Storage Capability Store and Trend 5 10 Years Worth of Data Having enough storage capacity is a critical factor at this level of power quality instrumentation How long can store data locally on the power quality meter before the system will have to start overwriting previously captured information A Power Xpert Meter has 512 MB of storage as standard and can be upgraded all the way to 1 GB In a typical power quality envi ronment this would provide storage capability for 5 10 years depending on the meter model Power Quality Index hid ha EZ WTDD Current O 4THD Voitage 1 39 K Factor 1 08 C Factor 1 50 Flicker Switchgear A An even
10. the same Ethernet connection Modbus TCP Master Modbus RTU Master Web Browser Modbus Slave Network Modbus RTU LCD Display Sub Network Web Enabled Advanced System Functionality This configuration provides full Modbus RTU TCP capabilities as well as direct Web browsing to individual meters In addition Web services are supported to Power Xpert Software This configuration is required for full Modbus and Power Xpert Software applications Modbus TCP Master Power Xpert Modbus RTU Master Software Web Browser Connections Fiharnet Deg play lek ASAS Medbus ATU 3 485 Modbus RTU LCD Display Sub Network 16 EATON CORPORATION Power Xpert 4000 6000 8000 Power Quality Meters Digital I O Card Usage Examples The Digital I O card option enables multiple sensor devices to be attached to the meter including alarm horns water on the floor door open or motion detection among others Solid state digital outputs support KYZ pulses and the three relay outputs can be easily connected to third party devices and controlled depending on the digital inputs Boolean functionality support Rack Monitoring Open Door Tamper Switch Eight digital inputs Flow Meter Pulse Count Two solid state digital outputs Three relay outputs Trip and Sequence of Events EATON CORPORATION Power Xpert 4000 6000 8000 Power Quality Meters 17 Powe r Xpe rt 4 Graphic Display Module 7 Auxiliary Voltage Input Channels
11. 4 42 200 ITIC Vin LA Sag this meter D d Events 04 Jan 08 05 4 4 1 841 TIC Von L2 Sag Deman Profile Chart Quick Links to i i Meter Setu e ability to seamlessly upgrade to a more powerful feature set that has earlier been available only on the Power Xpert 6000 Meters p ea is proud to offer a unique feature for existing Power Xpert 4000 Meter users with firmware version 12 x x release Upgrades can be purchased directly from the home page by clicking on the Upgrade to series 6000 button The self upgrade is available on e mail address Once you have Eaton s Web site You ll need a L pe the ability to upgrade to a Power Eaton understands that our customers needs change over time That s why we ve devel oped meters that can grow with you Once a Power Xpert 4000 Meter is purchased you have Xpert 6000 with no intervention from Eaton when needed All the features of the Power Xpert 4000 Meter that you have been using and depend on remain however once updated all the additional features of the Power Xpert 6000 Meter are available EATON CORPORATION Power Xpert 4000 6000 8000 Power Quality Meters credit card your Power Xpert 4000 Meter serial number and date code you will be presented with this info if you are using the upgrade link directly from your Power Xpert Meter and your completed the purchase we will send you your new license key information via e mail that will allow yo
12. Eaton s distribution generation and power quality equipment full scale engineering services and information management systems the power system is positioned to deliver powerful results greater reliability operating cost efficiencies effective use of capital enhanced safety and risk mitigation e s e en UNITED STATES CANADA LATIN AMERICA PowerChain Eaton Corporation Ontario 416 798 0112 Argentina 54 11 4343 6323 Electrical Group Toll Free 1 800 461 9166 Brazil 55 11 3616 8500 Management 8609 Six Forks Road M xico 52 55 9000 5252 Raleigh NC 27615 Toll Free 1 800 356 5794 Eaton Power Xpert and PowerChain or 919 872 3020 Management are registered trademarks of powerware com powerxpert Eaton Corporation Modbus is a registered trademark of Modicon a division of Schneider Electric Industries SA IEEE is a registered trademark of The Institute of Electrical and Electronics Engineers Incorporated EUROPE MIDDLE EAST AFRICA ASIA PACIFIC Microsoft and Excel are registered Denmark 45 3686 7910 Australia 61 2 9693 9366 trademarks of Microsoft Corporation Finland 358 94 52 661 New Zealand 64 0 3 343 3314 E E iN France 33 1 6012 7400 China 86 21 6361 5599 is a registered trademark of the U S Green Germany 49 0 7841 604 0 HK Korea Taiwan 852 2745 6682 Building Council Inc Italy 39 02 66 04 05 40 India 91 11 2649 9414 to 18 morei anil e a Ea Norway 47 23 03 65 50 Singapore SEA 65 6825 1668 in this
13. IT equipment e Boost IT equipment service life to the maximum Analyze sequence of events up to one millisecond time resolution Protect motors from damage Preserve the integrity of processes and batches Prevent blown capacitor bank fuses Protect transformers and conductors from overheating Detect and Record High Speed Transients Avoid equipment damage and disruption Identify equipment malfunction Monitor Circuit Loading Avoid overloads and nuisance overload trips Maximize equipment utilization Manage emergency overloads Manage Energy Utilization Reduce peak demand charges and power factor penalties Identify excessive energy consumption Features and Benefits e Embedded Web server see and analyze waveforms trends and harmonics directly in your Web browser or LCD meter graphic display e Automatic power quality analysis and trigger setting with built in ITIC performance curve detect and capture sags swells transients harmonics and flicker e Accurately detect fast transients that previous generation monitors would miss by assessing circuit activity at very high sampling rates up to 100 000 samples per cycle e Comprehensive power energy and demand measure ments for 138 standard data points logged e Voltage current per phase minimum maxi mum average trend graph analysis export print e Power power factor apparent real reactive frequency e Energy deman
14. a simple graphical representation Event calendar view MO MO The Events Timeline calendar view provides instant insight to the frequency of power events and helps detect reoccurring problems Events timeline view MO MO View and understand the sequence of events that have occurred during a period of time Sequence of events and events plot on waveform MO M Piotcolor coded events on a captured waveform to gain insight into the sequence of events cycle per cycle Power Quality Index Premium at a glance _ 2 Complex power quality data put into simple graphic format includes ITIC events and thermometer view of power quality flicker calculations High Speed Transient Capture amp Detection 6 MHz capture of impulsive transients Bi Capture impulsive transients by taking 6 samples every millionth of a second Transient capture duration 20 ms 6 MHz 120 ms 1 MHz a Record and analyze transients during a longer timeframe Waveform recorded at 100 000 samples per cycle E High speed ensures impulsive transients are correctly captured fast rise time Three phase voltage and neutral to ground fast H Capture impulsive transients on all 4 channels transient capture Delta Sigma A D oversampling rate These features are included with firmware release v 12 x x or higher NOTE These specifications are subject to change without notice and represent the maximum capabilities of the product wi
15. can be set up to support 4 different schedules Enables you to flash the meter with the latest firmware upgrades The meter can automatically adjust to the environment and alarm only when real events occur Power Energy amp Demand Voltage current per phase minimum maximum a E E Review voltage and current trends export print and analyze parameters right on the meter average trend graph analysis export print or external software Energy and demand plot comparisons HO MO MO Piottwo months or two weeks for vivid energy or demand comparison month to month week to week Power power factor apparent real reactive frequency W a E Review power usage and power factor and avoid potential PF penalties Energy demand forward reverse net sum TOU profile E E E Keep track of your energy usage compare time of usage and usage against previous month previous month comparison graph analysis export print identify peaks to conserve energy usage Power Quality Analysis Statistical Analysis min max average ii ai a Review statistical trends identify past and future problem areas Sag and swell monitoring management and recording a a E Capture electrical sags and swells and analyze the waveforms Symmetrical components zero negative positive E a E Analyze possibly unbalanced three phase power systems Low frequency transient detection and capture E a a Capture lower frequency transient waveforms for retrospe
16. ctive analysis or e mailing Sampling rate maximum samples cycle 1024 1024 100 000 Extremely high sampling rate will effectively capture impulsive transients Number of nines uptime data e g 6 nines 99 9999 et Review uptime availability percent K factor HO E O Review the ratio of eddy current losses e g when driving non linear and linear loads Crest factor HO E O Review the peak to average ratio of the waveform Security Secure 5 level user access privileges E a a Define appropriate security access level per user Communications amp 1 0 Modbus TCP a a a Easy integration with standard protocol to power management and other software Modbus RTU A E E Integrate meters to existing Modbus networks daisy chain several 1 16 meters together HTML Al a a Communicate to the meter over the Internet via standard Web browser SNMP Simple Network Management Protocol E E ei Communicate with the meter via Simple Network Protocol hook to existing NMS system SMTP Simple Mail Transfer Protocol H a _ Send e mail messages via standard Simple Mail Transfer Protocol FTP File Transfer Protocol u a ia Access copy paste cut waveform capture files on the meter with an FTP Client NTP Network Time Protocol 5 m E Network Time Protocol support enables the meter to synchronize time over the network up to the 1 millisecond resolution COMTRADE open IEEE standard file format for H E Import waveform captures in standard IEEE C37 111 1999 COMTRADE file for
17. d forward reverse net sum TOU profile previous month comparison graph analysis export print m ee y m u Pr ie a F fe Se Fr Az u i Tan a gt Up to one millisecond time synchronization and event logging capability for sequence of events analysis Get an at a glance view of power quality with patent pending Power Quality Index gauge statisti cally derived trending and red yellow green indicators for overall power health Support continuous non disruptive monitoring with a permanently installed meter Dramatically reduce the cost of monitoring power quality compared to yesterday s specialized power quality instruments and consultants Alarm notifications are also available remotely via e mail with waveform attached Use industry standard communication protocols to support a multitude of configurations and third party software HTTP FTP Modbus RTU Modbus TCP SNMP SMTP NTR COMTRADE 1 GB data storage capability Supported via Power Xpert Software and Power Xpert Architecture hardware components ANSI C12 20 accuracy 2m mE ST s i f m a ae i nn u a Ti ha ii a W TS z Power Xpert se ni RI en Meter og ry o Home Page gt wet u ul summariz es the pe we critical power graphical r home page viewed in amp The Power Xpert Metet ina single page
18. document are subject to change Sweden 46 8 598 940 00 without notice and represent the maximum United Kingdom 44 1753 608 700 esse son plete feature list Features and functionality may vary depending on selected options 2008 Eaton Corporation All Rights Reserved Printed in USA E A i W Powe rwa re Publication No PX02FXA Z7086 N May 2008
19. eter s embedded Web server supports viewing of triggered waveforms one channel at a time including the ability to zoom and to scroll horizontally using a slider bar Waveforms are stored in meter s non volatile flash memory using an industry standard COMTRADE format Waveforms can be automatically sent out by e mail following an event or can be retrieved from an FTP directory structure in mMeter s memory 3 aba Cuties Hamme Power pert Microsoft jaiem Lapdorer Pi Mami Mk Im A Pet N DE TR IE A Feb Di Fr Event ai ty been et Tee feb OT Se ge INC Care et en ee Bi heh TY 1 aa E Fah T7 17 DiE Sub Cy heb W7 1M TEE heb tF AILT E ee AILT Vi ee ANA ey OS eh U TR IT w el wee ee y EFT hoy 1em e mm eee February 05 2007 05 31 18 132 PM 0500 ITIC L4Sag Vir IN L ine dimaki al ott ng February 05 2007 6501 18 192 FM 1500 me Wien ver Qualit d 40 Q 60 00 80 4 Power Xpert Mieter Event Timeline View Screen Event Calendar View Screen View and understand the sequence of events that have occurred The Event Timeline calendar view provides instant insight to the during a period of time Plot color coded events on a captured frequency of power events and helps detect reoccurring problems waveform to gain insight into the sequence of events from one Color coded events can be filtered to detect specific issues firmware single cycle to the next one This provides the user an excellent v
20. fferent applications Digital inputs and relay outputs can be programmed to interact during various conditions defined by the user Various third party devices such as alarm pulse meters trip units Sensors can be easily integrated to the To find out more about how Power Xpert next generation meters can improve power performance for your critical systems visit our Web site at www powerware com powerxpert or contact us at 1 800 525 2000 18 EATON CORPORATION Power Xpert 4000 6000 8000 Power Quality Meters Power Xpert Meter Go Green The Power Xpert Meter Helps You Go GREEN Environmental stewardship innovation and leadership are becoming Increasingly important as we take steps to create a Sustainable environment for future generations by going green The Power Xpert Meter includes components that can help a building go green and qualify for Leadership in Energy and Environmental Design LEED credits through the U S Green Building Council USGBC Eaton offers several solutions that assist you In reducing your energy consumption Comparing Month to Month Energy Usage Go GREEN The Power Xpert Meter establishes a baseline of your energy usage It allows you to easily compare month to month energy usage graphs It will automatically store the energy data for exporting detailed analysis for example in Excel Receive periodic e mail alerts on energy consumption or triggered by thresholds you have
21. identify existing condi tions on an electrical distribution system or to evaluate past prob lems If you wanted to detect fast voltage transients you had to bring in portable power quality monitors that cost up to 20 000 and usually required an outside consultant Built in Graphing Six Samples Every Millionth of a Second Power Xpert 4000 6000 8000 next generation meters redefine the art of measuring and moni toring power quality Thanks to the latest technologies these metering instruments are able to measure trend analyze and capture waveforms while serving Web pages to users over the Internet along with simultaneous FTP downloading and comma separated values CSV exporting capabilities 2 One Millisecond Time Resolution Accuracy By taking readings at sub cycle levels like the Power Xpert 8000 model which can sample at a rate of 166 67 nanoseconds per sample Power Xpert Meters let you accurately see the detailed performance of each piece of gear they are connected to Time To understand the cause and effect of events you need to be able to analyze the interaction of equipment and the sequence of events This requires accurate time synchronization across the system No matter if you are a PhD level power quality engineer or an IT system administrator these instru ments will provide you with the level of information you need in an easy to understand graphical user interface at astonishing
22. irst come first served With 1 GB optional CompactFlash Card memory is not allocated by event category memory is used first come first served Takes the Guesswork Out of Understanding the Severity of IT Power Quality Events The ITIC Information Technology Industry Council curve describes how much or how little voltage your IT equipment can sustain without damage over what length of time nanoseconds to seconds When you can plot power events in this broader context relative to multiple variables you can identify trouble that could cause damage or may be brewing Of the few meters that can plot events on an ITIC curve most require special software to do it Eaton s OAAS a00 0110101071101010 Meters require no special software Out of the box these meters provide crisp graphics on minimum maximum average trends measurement gauges waveforms both on the local LCD display and the Web interface ITIC Curves The Power Xpert 6000 and 8000 Meter models automatically plot events on the ITIC curve The user can drill down on any specific event and get information on where exactly the event hit and what was its magnitude and duration With the optional Power Xpert Time Server all events get time stamped ata 1 millisecond synchronized resolution The ITIC Web page includes counters to track the occur rence of disturbances and a pass fail summary In addition selecting any disturbance counter lin
23. ks to a detailed event view of the disturbances in that ITIC category Disturbance waveforms can be viewed from the browser 3 B y EATON CORPORATION Power Xpert 4000 6000 8000 Power Quality Meters 11 Power Xpert Meter Power Xpert 4000 6000 8000 Meter offers Eaton customers a new level of accessibility to the critical information required to manage the electrical distribution system The meter s embedded Web server includes real time circuit information in both numeric and graphical visual formats to help monitor circuit parameters such as current loading voltage and power levels power factor Historical Trend Plot The Power Xpert 4000 6000 8000 Meter s embedded Web server supports graphical trend charts of key circuit measurements such Power Xpert 4000 6000 8000 Meter Home Page The Web server also provides the energy and demand readings required to help manage the cost of energy Readings include KWh KVARh delivered and received and KVAh with time of use and sepa as current voltage power and energy The trend chart supports a rate status Input controlled energy accumulation to account for energy zoom feature that allows the user to view data over a short period during special times such as rate alert periods or stand by generator of 18 hours or a longer period of 48 months The trend chart has times of operation The Web server on the Power Xpert Meters also a horizontal slider bar control to manage scrolling f
24. m e Depth 2 00 inches 51 mm e Shipping weight 2 1 Ibs 0 95 kg Auxiliary Voltage Terminal Voltage Terminal Meter Module Measurements e Height 8 20 inches 208 mm e Width 8 20 inches 208 mm Ne e Depth 5 86 inches without connectors 149 mm e Shipping weight 7 1 Ibs 3 22 kg 4 EATON CORPORATION Power Xpert 4000 6000 8000 Power Quality Meters a Internet Enabled ma Lo Ic IE BES os ou an Internet enabled includes a built in Web server next Events Timeline ei 2007 generation power quality meter A qe r r T a with comprehensive power ai e nn _ measurement and integrated N nn 22 aq amma e quality analysis The meter 2 ne sie a aaee allows you touse a standard Web browser to surf the meter and analyze waveforms trend and ITIC graphs is The Power Xpert Meter is cr LEA i a n _ R _ 2 a transit Power Xmert E T N Eveni a BE ann tn surasa ser m ion amp iS ww E r F Fu SS at ee ar oe Je February 05 2007 05 31 18 192 PM 0500 TC LdSag Won Ti W a TE ag wel bok ge Biek A ad LTE te A Peeks Pa PT i a HP as Cte PETE i a y Ce PL HET ee PT aay ek HE en ey i 1 z Li der eli ieai MA Hi ies Hi ge LI ieg TE U IE Feen fee OP EERTE eee u to TED en i Dr Tea an i a rt en fae Tr eae ioe Eh ee i Ur Tice ee February 05 2007 05 33 11 440 PM 0500 MC Laoag Ven Lhe Dr era
25. mat to waveform capture export third party software Trend measurements CSV file Export a m E Easily export trend measurements to third party applications e g Microsoft Excel in standard CSV file format I O 8 digital inputs 3 relay outputs E a a The Power Xpert I O Card is extremely flexible and can be used in a large variety of different 2 solid state KYZ outputs applications Digital inputs and relay outputs can be programmed to interact during various conditions defined by the user Various third party devices such as alarm pulse meters trip units and sensors can be easily integrated to the Power Xpert Meter Triggers and events can be tied to the meter s standard functions such as e g e mail logs and trends EATON CORPORATION Power Xpert 4000 6000 8000 Power Quality Meters FEATURES AND BENEFITS OF THE POWER XPERT 4000 6000 AND 8000 METERS Feature Power Xpert Benefit 4000 6000 8000 Time Synchronization NTP time synchronization up to 1 millisecond accuracy W E z Network Time Protocol support enables the meter to synchronize time over the network up to the 1 millisecond resolution GPS time synchronization up to 1 millisecond accuracy W 2 z The GPS option allows the meter to synchronize time over the GPS satellite positioning system up to the 1 millisecond resolution Logs Trend logging E a E Log trend information for easy statistical analysis Load profile O H O Review the load profile graph to get
26. orward and includes critical information regarding power quality such as harmonic backward through the data Trend charts of basic readings include distortion flicker crest factor K factor and more minimum maximum and average readings Trend charts of energy data also display demand values all J Ds A u OF e Event Ea Power Quality index EAN FATOR Sri Phase Phe fl hee i a PAR en BESI WWA Phases FALT WVA haere H Peel Piss FMS ea iT REAC TI PONER arieni Mhase H Priit i E kapel tee ator gen Beagle Cin a PRESENT 0 90 i awi MW 6 54 Lag MAS G57 Lead February 27 2007 1127 78 FM ee February 27 2007 07781 FM eee Sin repel are I E ptg i Mi u aus tz u See Harmonic Spectral Plot The harmonic spectral plot displays both harmonics and interharmonics up to the 85th order A detailed table also includes individual magnitudes and angles of current and voltage harmonics as well as a harmonic power calculation at each frequency Even Odd Interharmonic and total THD are displayed for diagnostic purposes Se ie Qu C E ee a LAET E T Hi Eveni AB Lins Line Vellage 200 ma avg ai eet Disturbance Recording Sag Swell Recording Sixty cycles of waveform are oversampled at 1024 samples 100 000 samples with the 8000 meter per cycle including 30 cycles of pre and post event data The Power Xpert 4000 6000 8000 M
27. oscillation transient resulting in equipment damage Absolute threshold and dV dt triggering E u a Detect and record if a surge suppressor is necessary Power Quality Index Standard at a glance HO u u Complex power quality data put into simple graphic format thermometer view of power quality Power Quality Index Enhanced at a glance HO Complex power quality data put into simple graphic format includes ITIC events and thermometer view of power quality flicker calculations Flicker calculations E T Detect and quantify low frequency rms voltage variations causing incandescent lighting flicker Automatic trigger setting a L Trigger thresholds are automatically set according to ITIC CBEMA standard no need to figure this out by yourself Automatic event severity analysis a Automatically analyze the severity of the event with the ITIC CBEMA performance curve plot see where the event actually hit Event severity counters E E An ITIC CBEMA event counter keeps track of the number of all sags swells and transients ITIC Information Technology Industry Council E E ITIC Information Technology Industry Council previously CBEMA performance curve for easy previously CBEMA performance curve power problem evaluation Custom ITIC CBEMA plot with individual event E al Review custom ITIC CBEMA plots of individual events showing you the actual magnitude magnitude and duration duration and hit are in
28. sis firmware v 12 x x and higher only and higher only E ae IN iu 166 99 13 85 jener A et ees Ba Bime pe Dee E fy 2 Power wert Meters E Power Xpert Architec SFTP directory fener Eaton Cutter Hammer FTP directory energy at 166 99 13 85 To view this FTP site in Windows Explorer click Page and then click Open FTP Site in Windows Explorer Waveform captures are automatically stored on the FTP server in the IEEE standard COMTRADE file format This allows users to view and analyze the waveforms in any standard free of charge or commercial COMTRADE file viewer E pi De aeons w fp Spreadsheet up G Power Managem i FTF director FTP directory waveforms at 166 99 13 85 Bi Fah Ol Haii To view this FTP site in Windows Explorer click Page and then cick Open FTP Site in Windows Explorer in R ha j Ba oo i Oo Oo oO oo nmin it m En En im tf ud ke a Ba Ba 1 h Ri hi f 5 0 0 oo oe ih b k ee h ee a ee W g ee ww wo i BJ BJ BJ ihe oo D T a oo 0 oo Mn oc oc ka Bi Ki BE Ba Jr i a RN A a ER A 4 aa _ P a E ez P ION Power Xpert 4000 6000 3000 Power Qua Meters ge 7 en Du Power Xpert Meter Configuration Communication Examples The Power Xpert Meters fit seamlessly into most any existing or new environments due to standard and open protocol support The Power
29. t occurs at time T1 FS Switchgear B An event occurs just after time 11 Switchgear C An event occurs just before time T1 Time Synchronized View Since the Power Xpert Server Solution allows switchgear A B and C to be synchronized with millisecond accuracy the sequence of events can be understood and analyzed 10 EATON CORPORATION Power Xpert 4000 6000 8000 Power Quality Meters 3 ITIC Curves Sample ITIC curve as displayed by the Power Xpert Meter Occurrence per Month Memory Usage MB Months of Capacity Months of Capacity w 512MB CF w 1GB CF Model Event File size KB Typical Severe Typical Severe Typical Severe Typical Severe PX 4000 Sub Cycle Disturbance 483 10 60 4 7 28 3 100 17 209 35 PX 6000 ITIC Event 483 5 20 2 4 9 4 200 50 417 104 Sub Cycle Disturbance 483 10 60 4 1 28 3 100 17 209 35 ITIC and Sub Cycle Total 15 80 11 8 66 0 40 7 83 15 a EA O O T O PX 8000 ITIC Event 483 5 20 2 4 9 4 200 50 417 104 Sub Cycle Disturbance 483 10 60 4 7 28 3 100 17 209 35 Transients 2048 3 30 6 0 60 0 79 8 164 16 ITIC Sub Cycle and Total 18 110 131 95 2 36 5 75 10 Transients Combined The typical and severe power quality event occurrences are estimates and may vary depending on the electrical environment With 512 MB standard CompactFlash Card memory is not allocated by event category memory is used f
30. th all options installed This is not a complete feature list Features and functionality may vary depending on selected options and product model Please refer to the technical data sheet and User Manual for detailed specifications EATON CORPORATION Power Xpert 4000 6000 8000 Power Quality Meters 9 Power Xpert Meter AWorld of Difference in Power Quality Analysis One Millisecond Time Resolution Most Accurate Time Available Harmonics voltage fluctuations transient overvoltage conditions and other power anomalies can wreak havoc on your equipment and processes It is essential to fully understand the quality of the power that is being delivered throughout the facility Detailed event information makes it pos sible to pinpoint the root causes of problems or prevent them from occurring With up to one millisecond time stamping accuracy available via GPS and IRIG time sources Power Xpert Meters register the sequence of events in a time synchronized environment Based on National Institute of Standards and Technology NIST atomic time you can count on the most accurate time available In the past basic power monitors were 1 Power Quality Index The patent pending Power Quality Index measures the temperature of your power quality The gauges alarm levels are based on current TDD voltage THD K and C factors flicker and ITIC events measure ments available on the 6000 and 8000 models only used to
31. u to complete the upgrade Power Xpert Meter Standard Enhanced Premium Three Flavors of Power Quality The Power Xpert 4000 Meter This meter provides all the core functions for monitoring power consumption and power quality This unit uses Delta Sigma technology to sample circuits at 1 024 samples per cycle for extremely accurate measurement of power factor and energy consumption The Power Xpert 6000 Meter This meter is geared toward the IT market by providing automatic FEATURES AND BENEFITS OF THE POWER XPERT 4000 6000 AND 8000 METERS Feature General Embedded Web server Power Xpert 4000 6000 8000 Benefit trigger settings for IT equipment and plots events on an ITIC Information Technology Industry Council performance curve so they can be very easily analyzed In addition this meter offers a patent pending Power Quality Index temperature gauge along with flicker calculations The Power Xpert 8000 Meter This meter adds the ability to capture very fast transients by sampling at 6 MHz 100 000 samples per cycle That s a sample every 166 nanoseconds six samples every millionth of a second across three input channels as well as neutral to ground Use a standard Web browser to monitor and manage the meter over the network Internet TOU metering support Firmware flash upgrade support Self learning capability wo characterizes normal per circuit Time of usage
Download Pdf Manuals
Related Search
Related Contents
Renesas H8S/2214 Series User's Manual Potatore - Centro Verde Rovigo OmniMount MODENA 47FP FNAS MODE D EMPLOI 平成25年9月発行(全文) [PDFファイル/1.41MB] 取扱説明書 - シチズン・システムズ Breville VBL074 blender Hydrographie Information Processing System Epson PowerLite Pro Cinema 1080 HQV User's Guide Copyright © All rights reserved.