Home
MIYMD ManDown Sensor User Manual
Contents
1. 11 User Manual 953 89a F 01U 278 523 2012 11 Page 5 of 12 MIYMD ManDown Sensor 1 Introduction The MIYMD ManDown Sensor has a built in tilt device which can detect if the person hold ing it is in a horizontal position such as lying on the floor The sensor will automatically send an alarm when its position corresponds to horizontality after a certain time Pressing its central bed button will activate a help call at any time It can be held for instance as a necklace by an elderly person or as a safety device by a lone worker in a hazardous environment The MIYMD ManDown Sensor will be part of a Resident Alert System Help call button LED Fig 1 ManDown Sensor 2 Description The MIYMD ManDown Sensor is equipped with a LED indicator that will flash every ten seconds to show that the sensor is active This LED indicator will flash green if the battery is ok or red if the battery is low Pushing the central red button will send a help call to the social alarm system followed by a short beeping sound Caution A help call is sent only after the central red button has been released The user should be aware that pressing the central red button must be short If the central red button is being pressed longer that five seconds the sensor will be turned off and no help call will be sent See chapter 4 2 Turning off the sensor User Manual 953 89a F 01U 278 523 2012 11 Page 6 of 12 MIYMD ManDown Sen
2. 12 MIYMD ManDown Sensor 4 3 Detection mode Detection by the MIYMD ManDown Sensor can be decomposed into two periods of time 1 Tilt Detection When the sensor detects a tilt of more than 60 degrees it will start its internal chronometer for approximately ten seconds If the sensor comes back to a vertical position within these ten seconds the chronometer is reset 2 Pre Alarm If the sensor does not come back to a vertical position within ten seconds a pre alarm starts accompanied by a beeping sound This period of time is factory set and lasts approximately thirty seconds The pre alarm is cancelled if the sensor comes back to a vertical position or if the help call button is pressed This pre alarm may be suppressed by making a solder bridge See Fig 2 Interior view of a MIYMD ManDown Sensor 4 4 Repeating the alarm After a fall as long as the sensor detects a horizontal position the alarm will repeat itself after an average period of time of two minutes and thirty seconds 4 5 Deactivating the help call button and the pre alarm Making a solder bridge allows to deactivate the help call button or to suppress the pre alarm In this case during the automatic tilt alarm the sensor remains silent During all help calls made by pressing the button the sensor will always issue a beeping sound No bridge with pre alarm Bridged without pre alarm Fig 2 Interior view of a ManDown Sensor No bridge help call b
3. BOSCH MIYMD ManDown Sensor User Manual 953 89a F 01U 278 523 2012 11 Document 953 89a F 01U 278 523 MIYMD ManDown Sensor User Manual Edition December 2012 Author TeleAlarm TeleAlarm SA 2012 All rights reserved TeleAlarm SA reserves the right to make changes to information contained in this document at any time without prior notice Great care has been given to the contents of this document However TeleAlarm SA cannot be held liable for the consequences of any errors or omissions contained herein or for consequen tial or incidental damages incurred as a result of acting on information contained in the document Robert Bosch Healthcare Systems Inc 2400 Geng Road Suite 200 Palo Alto CA 94303 U S A Phone 650 690 9100 Toll Free 1 888 947 8957 Fax 650 798 3770 www bosch telehealth com User Manual 953 89a F 01U 278 523 2012 11 Page 3 of 12 User Manual 953 89a F 01U 278 523 2012 11 Page 4 of 12 MIYMD ManDown Sensor 1 Introduction 2 Description 3 Compatibility of the MIYMD ManDown Sensor 4 Operating 4 1 Starting the sensor 4 2 Turning off the sensor 4 3 Detection mode 4 4 Repeating the alarm 4 5 Deactivating the help call button and the pre alarm 5 Programming the MIYMD ManDown Sensor 6 Maintenance 6 1 Safety instructions 6 2 Storage 6 3 Replacing the battery 7 Technical Specifications 8 FCC Warning Statement Table of Contents 10 11
4. conds of signal before automatic activation VARTA 3V CR1 2AA or equivalent Lithium 3 0V diam 14 5mm x 25mm lt 5 yA if the MIYMD ManDown Sensor is deactivated lt 13 pA if the MIYMD ManDown Sensor is on stand by from six months to two years depending on operation and the number of detections performed ABS Cycolac GPM5500S white 25020 with fire classification UL 94 HB 8 FCC Warning Statement This equipment complies with Part 15 of the FCC rules Any changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipment This device complies with Part 15 of the FCC rules subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept all interference received including interference that may cause undesired operation User Manual 953 89a F 01U 278 523 2012 11 Page 11 of 12
5. he sensor Long term storage more than two weeks Remove the battery and store the MIYMD ManDown Sensor protected from direct sunlight moisture and dust User Manual 953 89a F 01U 278 523 2012 11 Page 9 of 12 MIYMD ManDown Sensor 6 3 Replacing the battery Necessary tool for opening the sensor case Jeweler s Screwdriver 0 114 in 2 9mm Turn off the MIYMD ManDown Sensor See chapter 4 2 Turning off the sensor Unscrew the four screws of the case as shown in Fig 3 Bottom view of the MIYMD ManDown Sensor Carefully remove the compression foam as well as the used battery Replace the new battery ensure that it is in the correct position Carefully place the compression foam as shown in Fig 4 Opening the MIYMD ManDown Sensor Close the case with the four screws The arrows show the screws of the transmitter case Fig 3 Bottom view of the ManDown Sensor Notice To avoid deteriorating the inserts do not force the screwing VARTA battery 3V CR1 2AA E E Fig 4 Opening the ManDown Sensor User Manual 953 89a F 01U 278 523 2012 11 Page 10 of 12 MIYMD ManDown Sensor 7 Technical Specifications Dimensions Frequency Tilt sensor Pre alarm Battery Consumption Battery lifetime Type of plastic 2 95 x 1 6 x 1 in 75 x 40 x 23 mm 434 Mhz Mercury free type with activating at a 60 angle with vertical 10 seconds of detection followed by 30 se
6. sor 3 Compatibility of the MIYMD ManDown Sensor The MIYMD ManDown Sensor must always be associated with a corresponding Resident Alert System according to the following table Type of MIYMD ManDown Sensor Social alarm system MIYMD ManDown 434 MHz TeleAlarm Bosch Resident Alert System protocol 4 Operating 4 1 Starting the sensor When the MIYMD ManDown Sensor is off the user only has to press the central red button to turn it on A slow beeping sound will then confirm that the sensor is active Notice No help call transmission will take place during this operation 4 2 Turning off the sensor Press the button for about five seconds A beeping sound is emitted during two seconds During these two seconds release the button and press it a second time The sensor is then turned off This last step will be confirmed by a slow beeping sound It is always possible to turn off the sensor even when the help call button is deactivated Notice A help call will be activated only after pressing the help call button for less the five seconds and releasing the central red button This means that during the procedure of turning off the sensor no alarm will be generated If the central red button is being pressed and released less that five seconds or pressed longer than seven seconds a help call will be generated See chapter 2 Description User Manual 953 89a F 01U 278 523 2012 11 Page 7 of
7. utton activated Bridged help call button deactivated User Manual 953 89a F 01U 278 523 2012 11 Page 8 of 12 MIYMD ManDown Sensor 5 Programming the MIYMD ManDown Sensor To program a MIYMD ManDown Sensor within a Resident Alert System follow the procedure described for the system you are using As the MIYMD ManDown Sensor can be considered as a standard transmitter the system will recognize it during the programming step Please refer to the manual of the corresponding Main Unit 6 Maintenance 6 1 Safety instructions Caution There is a danger of explosion if the replacement of the battery is not performed correctly Replace the battery only by an identical or equivalent type Dispose of the used batteries at an appropriate recycling facility Although battery replacement may be done by non specialized person nel the manufacturer recommends that it should be performed by your local dealer A AA Caution The MIYMD ManDown Sensor contains highly sensitive electronic com ponents It should always be opened in an ESD Electro Static Dis charge protected environment with respect to the following precau tions Discharge yourself from electrostatic loads by touching a grounded conductive surface before opening the unit Avoid touching conductive parts and metallic surfaces if not absolute ly necessary 6 2 Storage Short term storage less than two weeks Deactivate t
Download Pdf Manuals
Related Search
Related Contents
Navigator User Manual Weatherables WKG-THDVA36-S60 Instructions / Assembly LG 55LA9609-ZA User's Manual Ryobi P117 Use and Care Manual Marley Sigma F Series Cooling Tower Bedienungsanleitung Tripp Lite B060-032-8 KVM switch Scanning ARTS2 for WIN のインストール方法 ~Windows XP 環境~ Copyright © All rights reserved.