Home
FLEX-MATE K500
Contents
1. Using a 1 Phillips screwdriver remove the screw that secures the motor to the motor plate of the frame Discard old motor assembly screws and washers Remove the rubber grommets from the motor plate and discard Wipe off any built up debris from the motor plate with clean dry cloth 8 11 2 To replace the Motor Assembly Insert the four rubber grommets from kit into the motor plate Install the new motor assembly into the unit through the motor plate Secure the motor with the provided washers and screws Do not tighten motor Install the 1 x1 pad enclosed under the aluminum rail such that one edge matches the edge of the rail and the other edge is flush with the end of the motor Tighten the motor screws using 7 64 Allen Wrench Reattach the optical sensor to the bracket of the motor Assure that the encoder wheel is centered between the posts of the optical sensor Plug the 5 pin connector from the motor into the header marked J5 optical sensor The connector wires are Red Green Black White when viewed from left to right Reinstall the belts between the dual pulley and the motor pulley Reinstall the belts between the dual pulley and the large pulley Replace housing and secure with push rivets P N 1 00060 Revision A 21 SECTION 8 12 TRANSFORMER REPLACEMENT INSTRUCTIONS For use with kit number 71290 and kit number 76520 Tools required Slip lock Pliers Small Flathead Screwdriver Small Diagonal Cutters Adjustable Wr
2. End Removal Rod End Installation Brush Rod Replacement Instructions Weather Stripping Removal 1 10 11 13 17 y Q Q OQOQOGORARAOON o 68 O 11 12 14 14 15 16 17 17 18 18 18 8 8 2 Brush Removal 19 8 8 3 Brush Installation 19 8 9 Handle Replacement Instructions 8 9 1 Handle Removal 19 8 9 2 Handle Installation 19 8 10 Optical Sensor Replacement Instructions 8 10 1 Sensor Removal 19 8 10 2 Sensor Installation 20 8 11 Motor Replacement Instructions 8 11 1 Motor Removal 21 8 11 2 Motor Installation 21 8 12 Transformer Replacement Instructions 8 12 1 Transformer Removal 22 8 12 2 Transformer Installation 22 8 13 Housing Replacement Instructions 8 13 1 Housing Removal 23 8 13 2 Housing Installation 24 8 14 Electronics Upgrade Replacement Instructions 8 14 1 Electronics Removal 25 8 14 2 Electronics Upgrade Installation 25 8 15 Miscellaneous Parts List 26 8 15 1 Electronic Replacement Parts List 27 SERVICEABILITY LIMITATIONS 06500 Flexmate K500 domestic Primary input 120VAC 60Hz 25W The FLEX MATE K500 is a CLASS 1 device based on its type of protection against electric shock Itis a TYPE B APPIED PART device based on the degree of protection against electric shock The degree of protection against ingress of water is ordinary It primary mode of use is continuous FLEX MATE K500 can be transported and stored in an environment of 40 F to 158 F 40 C to 70 C w
3. Reinstall the screws and secure snugly 4 Install the power cord into the lower housing and secure with the right angle strain relief For the molded strain relief position the relief to face away from the power switch as to not interfere with its operation and plug the power connector to the board Plug the DC power plug into its port and secure with the 4 cable tie Reconnect the flag connectors to the power switch and the ground wire to the frame 5 Thread the potentiometer and controller wires through the appropriate holes and secure them to the housing For the controller and potentiometer cables with the molded relief insert the relief into its keyway and twist it 90 to lock it into place 6 Reconnect the wires to their appropriate connections on the PC Board Controller J1 Transformer J2 Motor J3 Potentiometer J4 Optical Sensor J5 Oe a E 7 Reattach the upper housing portions to the lower housings with the plastic push rivets 8 Reinstall the handle onto the side of the unit with the 8 32 x7 8 flat head screws and press the handle caps into position Section 8 14 Electronics Upgrade Replacement Instructions For use with kit number 73616 Also for kit number 76523 in part NOTE As stated in Section 4 of this manual there have been modifications made to the Flexmate K500 Motor PCB Due to these changes it may be a requirement that all electronic components be updated at the same time It
4. any wiring secured to the frame of the CPM unit 5 Remove the strain relief from the housing sections with strain relief pliers and discard the bushings Remove the wires that are threaded through the openings potentiometer and controller and discard the controller Note If the cables being removed from the housing have a molded strain relief at the housing it is an upgraded unit and will not require cable removal from the housing Reference note above this section for further details 6 Remove the potentiometer from its mounting per Section 8 3 page 10 of this manual and discard 7 Unscrew the Motor PCB from its mountings Discard PCB but set the screws aside for the installation of the new PCB 8 14 2 Installation of the Electronics Upgrade Package 1 Install the new potentiometer per Section 8 3 2 steps 1 3 of this manual page 11 2 Carefully feed the cables for both the new potentiometer and controller through the housing as to not damage the wiring if the connectors 3 Position the new motor PCB to the mounting points within the housing with the J2 power connector pointed away from the motor Secure with the screws that were removed from the old motor PCB 4 Carefully pull the controller and potentiometer cables to the motor PCB and connect to the appropriate headers listed below Controller J1 Potentiometer J4 5 Connect the remaining wires to the appropriate headers listed below Transformer J2 NOTE If th
5. backing off of the supplied Velcro loop and attach to the back of the controller label Section 8 7 ROD END BALL JOINT REPLACEMENT INSTRUCTIONS For use with kit number 71230 Tools required 5 32 Allen Wrench Slip Lock Pliers Sec 8 7 1 To remove the existing Rod End Ball Joints 1 Remove screw connecting the lower extension to the frame 2 Remove rod end from frame NOTE If the rod ends will not turn due to rust corrosion or damage Use the slip lock pliers to carefully turn the rod ends until they turn freely A small amount if WD 40 can be sprayed on threads to help loosen the cause of the binding Sec 8 7 2 To replace the Rod End Ball Joints 1 Insert rod end into frame 2 Install screw connection the lower extension to the frame 3 Plug transformer into wall and start the unit to assure proper tracking of the upper assembly If the leg supports are tracking properly tighten rod end screws 4 Ifthe assembly is not tracking properly remove screw on opposite side of the direction of the tracking and turn the rod end out by turn and reinstall screw Allow unit to run 2 3 cycles and verify if the unit is tracking properly If correct tighten rod end screws If not repeat this step until proper tracking is achieved SECTION 8 8 __BRUSH ROD REPLACEMENT INSTRUCTIONS For use with kit number 71240 Tools required 3 32 Allen Wrench Slip Lock Pliers Flat Screwdriver Sec 8 8 1 To remove the existing Weather Stripp
6. bracket using a 3 32 Allen Wrench Discard screws and bracket 6 Remove set screws from the upper part of the calf support using a 5 64 Allen wrench and remove press fit bushing from unit and discard 7 Disconnect the potentiometer connector from the header marked J4 on the Motor PCB 8 To remove the Heyco strain relief from housing for serial numbers beginning with 1 use either a regular pair of slip lock pliers or strain relief pliers compress the strain relief to remove the strain relief from the housing then pull cord out and discard the old potentiometer assembly To remove the potentiometer cables from CPMs that have a serial numbers that start with the number 2 grasp the molded strain relief near the base with either the slip lock or strain relief pliers and turn counter clockwise 90 Then pull the cord out and discard Sec 8 3 2 To install a new potentiometer assembly NOTE Before the installation of the potentiometer verification of the 10 through the 120 range must be performed To achieve this connect the potentiometer cable to the J4 connector on the motor drive board Plug the CPM transformer in and turn on the CPM unit at the power switch The display on the hand held controller should be lit Grasp the potentiometer in one hand and slowly turn the bushing counter clockwise until 10 is displayed Slowly turn the bushing clockwise until the display reaches 120 Once the 120 position has been re
7. is recommended in order to assure compliance and reliability of the Flexmate K500 Knee CPM that the following components be upgraded This upgrade is intended for Flexmate units that have the older model Motor PCB see Section 5 page 4 for details Full Upgrade Package includes e Motor PCB e Controller PCB e Controller Cable Potentiometer Assembly includes cable NOTE This section is for the replacement of the complete upgrade with references made to previous sections of this manual for individual component replacement P N 1 00060 Revision A 24 Tools Required 1 Phillips Screwdriver 2 Phillips Screwdriver Flathead Screwdriver 5 64 Allen Wrench 3 32 Allen Wrench Needle Nose Pliers Straight Edge Slip Lock Pliers Strain Relief Pliers 6 Ruler or Tape Measure Small Diagonal Cutters 8 14 1 Removal of the electronics from the Flexmate K500 1 Switch unit off and unplug the transformer from the wall 2 Remove the push rivets from the smaller portion of the upper housing of the unit by lifting the head of the rivet with a small screwdriver Remove small housing section and set aside with the push rivets for later installation 3 Open wire clips with the small flathead screwdriver and remove wires from clips 4 Disconnect the connectors from the headers on the motor PCB Controller J1 Transformer J2 Motor J3 Potentiometer J4 Optical Sensor J5 Note Cut cable tie securing the DC plug to the PCB and
8. new pulley system incorporates the use of 3 round belts that will run from the dual pulley to the large drive pulley It also uses 3 thinner round belts that run between the dual pulley and the motor pulley If the belt of the 2 set between the motor and the dual pulley is flat then the motor assembly kit number 71280 must be changed also 6 To remove leadscrew from the CPM unit the flanged bushing on the pulley end will need to be removed First remove the extrusion weather stripping or nylon brushes fingers and discard Place the open end of the 7 16 wrench over the leadscrew against the bushing and gently tap the wrench with rubber mallet until bushing is free of the motor plate Take care not to damage bearings inner race Set bearing aside until reinstallation 7 Untie the calf support from the thigh support and slide the lead screw out of the motor plate Turn the lead screw until it is free of the unit Discard lead screw 8 Turn the nut housing to allow the removal of the orange ACME nut that is inside of the nut housing Discard the ACME nut If the CPM unit has a built in oiling felt remove it and discard also see note below NOTE There are 2 configurations for the nut housing The difference between them is the 2 newer configuration incorporates a felt oiling pad inside the housing and is distinguishable by an increased length and a small hole on the top of the housing for applying the oil to the pad It
9. push the red and black wires deeper into the connector Reattach connector and turn on power Use a multi meter to test voltage at motor after pressing the Start Stop button See voltage chart Pg27 If there is voltage to the motor but the motor is not running replace motor If there is no voltage to the motor replace P C Board If still no voltage to the motor replace the pendant Note If this solves the problem test the original P C Board it may be okay Check to see if settings are locked If locked a dot will appear in the lower right hand corner of the display To remove lock press both the UP and DOWN arrows at the same time If unlocking does not work replace pendant If this still does not work replace the P C Board Note If this solves the problem test the original pendant it may be okay Start unit Set extension limit to 0 Stop unit when 0 is displayed on the pendant Visually check to see that the Leg Carriage is perfectly straight If the carriage is not aligned properly calibrate the range of motion as dictated in Section 7 1 of this manual Inspect the position of the encoder wheel within the optical sensor If it is contacting the sensor reposition the encoder wheel Inspect the area just below the rear of the motor for debris P N 1 00060 Revision A 4 motion with or If a black powder is evident replace motor without load Inspect the inside of the extrusion rai
10. that the unit will not bind during operation allow for approximately 1 16 play 11 Replace upper housings and push rivets Section 8 3 POTENTIOMETER REPLACEMENT CALIBRATION INSTRUCTIONS For use with kit number 71190 or 76524 NOTE Kit number 71190 incorporates a Heyco strain relief to secure the cord to the housing and is used on CPMs with serial numbers beginning with 1 CPM units with serial numbers beginning with 2 use kit number 76524 and incorporate a molded strain relief to secure the cord into the housing These kits are not interchangeable Tools required Phillips Screwdriver Flat Head Screwdriver 5 64 Allen Wrench 3 32 Allen Wrench Needle Nose PliersStraight Edge Pliers or strain relief pliers 6 Ruler or Tape Measure NOTE When replacing the potentiometer there are three phases Removal Installation Calibration Sec 8 3 1 To remove the existing goniometer assembly 1 If unit is operational Turn unit on and start into flexion position until all screws on goniometer housing can be reached 2 Switch unit to off and unplug the transformer from the wall 3 Remove the push rivets from the upper housing of the unit by lifting head of rivet with a small screwdriver remove smaller cover and set aside Be sure to place rivets where they will not be lost 4 Remove Potentiometer Housing using a Phillips head screwdriver discard screws 5 Remove the 2 socket head screws from the goniometer
11. they will not be lost 3 Unplug connector for the optical sensor from the header on the PCB marked J5 4 Using a 1 Phillips screwdriver remove the screw that secures the optical sensor to the motor assembly 5 Using a small flathead screwdriver open the wire clip securing the wire 6 Discard old optical sensor and wire Sec 8 10 2 To replace the Optical Sensor Assembly 7 Secure the optical sensor to the motor assembly with the provided screw Verify that the chamfer is positioned towards the motor PCB and the encoder wheel is centered between the two posts of the optical sensor as indicated in fig 8 Chamfer fig 8 fig 9 8 If the optical sensor wire was not connected to the optical sensor verify that the leads are twisted in the proper direction as indicated in fig 9 9 Attach the 5 pin connector shown in fig 10 and 11 to the optical sensor Use a nylon cable tie to secure the cable tie to the optical sensor as shown in fig 11 Red Green Open Black White eto c On On fig 10 fig 11 fig 12 10 Plug the optical sensor connector into the header marked J5 as indicated in fig 12 11 Secure the optical sensor wire to the optical sensor by threading a small wire tie through the hole of the optical sensor wrapping the tie around the wire and pulling it tight Cut off the excess wire tie P N 1 00060 Revision A 20 12 Replace the cover and secure with push rivets SECTION 8 11 MOTOR REPLACEMENT I
12. 20 and the display is not flashing then the calibration process is complete If the display does not read 120 or if it is flashing between angles the flexion limit will need to be set Locate the R5 variable resistor With a small flat screwdriver turn the adjustment screw until the display on the pendent reads a steady 120 Once the 120 position has been set start the CPM and allow it to run down to the 0 position Verify the 0 position P N 1 00060 Revision A 13 7 Ifthe 0 position is verified complete the installation process above If 0 position cannot be verified repeat the calibration process Section 8 4 LEAD SCREW REPLACEMENT INSTRUCTIONS For use with kit number 71200 Tools required Rubber Mallet Slip Lock Pliers Diagonal Cutters Retaining Ring Pliers 1 64 Allen Wrench 3 32 Allen Wrench 1 8 Allen Wrench 5 32 Allen Wrench Small Flathead Screwdriver 2 Foot Of Light Weight Rope or String 0 Phillips Screwdriver 7 16 Open End Wrench Sec 8 4 1 To remove the existing lead screw 1 Turn unit on and start into complete flexion 120 Using the lightweight rope or string secure calf support to thigh support 2 Switch unit to off and unplug the transformer from the wall 3 Remove the push rivets from both halves of the upper housing of the unit by lifting head of rivet with a small screwdriver remove smaller cover and set aside Be sure to place rivets where they will not be l
13. 2120 7 01761 Component part numbers listed are subject to change without prior notice to the customer 8 15 1 Electronic Replacement Parts List These components must be installed in a static free environment Failure to do so may render the electronic components inoperable gi When upgrading an older motor board these components must be installed together at the same time Failure to install as a set the PCBs will fail and severely damage the other electronic components within the system Controller Chip 9 28451 Controller PCB 6 01131 Motor PCB 6 01130 Cable Controller No Molded Strain Relief 9 00060 Cable Potentiometer Molded Strain Relief One End 0 34545 Cable Potentiometer Molded Strain Relief Both Ends 0 34540 To Verify Positive TP Negative TP Adjustable VDC Y N X Transformer Voltage 4 3 No 22 0 22 8VDC Old Board 10 2 3 Yes R6 425 450 mVDC New Board Extension Overload 08 ext 2 3 Yes R6 125 002 mVDC Flexion Overload 08flex 2 3 Yes RI 425 002 mVDC Motor Voltage Red Lead Black Lead No 11 4 11 8 VDC P N 1 00060 Revision A 27
14. ID 7 01900 Clip Wire Adhesive Backed 7 01980 Cotter Pin 3 32 OD x 1 0L 5 01770 Foam Insert Box FM K500 2 01030 Grommet 1 8 ID x 25 Groove 7 01910 Hook 2 PSA 3 00110 Housing Bottom FM K500 for Heyco strain relief 7 01810 Housing Bottom FM K500 for molded strain relief 7 01870 Housing Top K500 for Heyco strain relief 7 01780 Housing Top K500 for molded strain relief 7 01875 Housing Potentiometer Cap fits cable w strain relief only Label Flexmate K 500 1 07640 Label Scale PSA Flexmate Extension 1 01940 Label CPM Oiler Location 1 14680 Lubricant Grease Clear Non Tox 4 01020 Lubricant CPM Oiler 0 29800 Lubricants Multi Purpose 1 Gal 4 01070 Manual Operation FM K500 1 07080 Manual Service Flemate K500 1 00060 Measuring Tape BREG Logo 9 11440 Nut 1 4 20 Nylon Locking 5 15260 Pad Non Skid Large F Mate 9 02400 Plug 687 Hole 5 02390 Plug Flat Head 3 4 O D 7 01260 Retaining Compound Retaining RNG External 352 GRV 025 thick Rivet Plastic 200 OD Screw 10 x 5 8 LS T Screw 8 32 x 318SS Screw 8 32 x 7 8 Flat Head Screw Carriage 1 4 20x1 5 SS Screw Set 8 32 x 50 SS Screw Set 8 32 x 3 16 SS Set Screw 10 24 x 1 2 Full dog Set Screw 10 24 x 1 4 Thread Locker Permanent Washer 1 25 x 311 x 05 T Nylon Washer 9 16 x 3 8 x 1 32 Nylon Washer Punched K500 4 00780 9 01270 5 01460 5 01430 5 01420 5 01470 5 01990 5 02020 5 02140 5 02430 5 02440 4 00520 7 01760 9 0
15. KLC Services Inc 4038 Weaver Ct East 614 921 8866 Columbus OH 43026 866 532 3534 FX 800 329 2734 FLEX MATE K500 SERVICE MANUAL WARRANTY TABLE OF CONTEXT Section 8 8 1 P N 1 00060 Revision A Title Serviceability Limitations Warranty Information Routine Maintenance Schedule Basic Troubleshooting During Warranty Period Basic Troubleshooting Out of Warranty Period The Flex Mate K500 Motor PCB Cable Connections Test Points and Variable Resistors Calibration Processes For The Flex Mate K500 Knee CPM Range Limit Calibration Limits of Reversing Load Calibration of older model PCBs Calibration of current model PCBs Servicing and Repair Instructions Available Kitted Parts List Pulley Replacement Instructions Pulley Belt Removal Pulley Belt Installation Bearing Replacement Instructions Bearing Removal Cotter Pin Removal Nylon Lock Nut Removal Flange Bearing Pulley Installation Flange Bearing Thrust Bearing Installation Cotter Pin Installation Nylon Lock Nut Installation Potentiometer Replacement Instructions Potentiometer Removal Potentiometer Installation Potentiometer Calibration Lead screw Replacement Instructions Leadscrew Removal Leadscrew Installation Nut Housing Replacement Instructions Nut Housing Removal Nut Housing Installation Reinstalling the Leadscrew Membrane Switch Replacement Instructions Membrane Switch Removal Membrane Switch Installation Rod End Ball Joint Replacement Instruction Rod
16. NSTRUCTIONS For use with kit number71280 Tools required 0 Phillips Screwdriver 1 Phillips Screwdriver Small Flathead Screwdriver 7 64 Allen Wrench NOTE Before the replacement of the motor assembly view the pulleys installed into the unit These pulleys should incorporate the use of 3 10 11 12 13 14 15 16 17 round belts connecting the pulleys These pulleys are easily distinguishable by the grooves and gray color The small pulley of the motor should also have grooves If any of the pulleys installed require flat belts it will be necessary to replace the following components also The pulley assembly kit number 71160 and the leadscrew kit number 71200 8 11 1 To remove the existing Motor Assembly Switch unit to off and unplug the transformer from the wall Remove the push rivets from the lower end of the unit portion with labeling near power cord by lifting head of rivet with a small screwdriver and remove cover Be sure to place rivets where they will not be lost Remove belts from the large set aside Remove the 3 belts from the Dual Pulley Set belts aside With a 0 Phillips screwdriver remove the optical sensor from the bracket on the motor Set the sensor out of the way but do not disconnect it from the board Set the screw aside to where it will not be lost If there is a cable tie securing the connector to the optical Unplug connector for the motor from the header on the PCB marked J3
17. ached slowly turn the bushing counter clockwise until the display reaches 0 1 Hand rotate the CPM carriage to a near 0 angle 2 Oil the press fit bushing on the potentiometer with a light weight oil and insert it into the hinged area knuckle Align hole in bushing to the set screw hole and install the 72 long set screw followed by the second set screw making sure to tighten both snugly P N 1 00060 Revision A 12 10 11 Thread the cable through the opening for the potentiometer For CPM units with a serial number beginning with the number 1 compress the Heyco strain relief and insert it into the opening to secure the potentiometer cable For CPM units with a serial number that begin with the number 2 insert the molded strain relief into the key hole and turn it 90 counter clockwise to engage the locking mechanism Connect the potentiometer connector to the header on the Motor PCB labeled J4 Turn the CPM on at the power switch to allow viewing of the angle on the controller Turn the potentiometer by hand to 0 Slowly turn the potentiometer clockwise while viewing the display to assure that the component is reading the correct 10 120 range Turn the potentiometer in the opposite direction to return it to the O position Place potentiometer bracket into the slot on the potentiometer and install the socket head cap screws using the 3 32 Allen wrench Do not tighten screws until 0 degree mark has
18. ange limit as with the earlier model but splits the Load Limit settings for the Flexion R1 and the Extension R6 It is recommended that if either an earlier model Motor PCB fig3 is being replaced in the CPM unit the controller board chip be replaced at the same time Section 5 Cable Connections J2 Power Connector J3 F pire a t hihins ary To Pe ee ee en i Ti Ei Vek pE LA E ir ha sl 5 im B ani T f asd os Fa E r ERS HAIGE te i J d r Li i r a gt a r x r i p 4 i i Fa ee n Hols Bo o row P N 1 00060 Revision A 5 Section 6 Test Points and Variable Resistors Figure 1 Motor PBC is the earlier model PCB for the Flex mate K500 Most CPM units with a serial number that begins with 1 will have this board installed unless it is a demo unit or has been updated Figure 2 Motor PCB is the newer UL60601 approved board This board will be in use with all K500 CPM units that have a serial number beginning with 2 unless it is a demo unit or has been updated during routine maintenance Identification of the boards may be achieved in a number of ways Easiest means is to identify the J2 power connector see fig 1 and fig 2 The earlier motor board will have a black DC plug fig 1 while the UL60601 version will have a white connector fig 2 The second means of identification is to scan the board for the number of variable resistors mount
19. anty is void if within the warranty period the K500 has been serviced parts removed tampered with or replaced or any other actions taken beyond the scope of Routine Maintenance and Basic Troubleshooting as specified in the service manual by any party other than KLC Services Inc In the event the K500 exhibits a defect in material or workmanship during the warranty period KLC Services Inc will at no additional charge repair or replace defective parts or the entire unit at KLC Service s option Except for the warranties and conditions set forth herein KLC Services Inc disclaims all other warranties express or implied or statutory including but not limited to the implied warranties of merchantability or fitness for a particular purpose Any implied warranties that may be imposed by applicable law are limited to the terms of this limited warranty No other warranties express or implied are given and no affirmation of or by KLC Services Inc by words or action will constitute a warranty In no event shall KLC Services Inc be liable for any incidental special or consequential damages including but not limited to loss of business revenue profits data or use whether in an action in contract or tort or based on a warranty arising out of or in connection with the use or performance of the K500 or any software supplied by KLC Services Inc that accompanies the K500 even if KLC Services Inc has been advised of the possibility of such da
20. been set in Steps 8 and 9 Plug transformer into wall and start the unit into extension mode until the bars of both the thigh and calf supports are in alignment This step can also be done by hand Use a straight edge to verify Once alignment has been confirmed carefully turn potentiometer until readout on the controller reads 0 degrees Tighten the screws with a 3 32 Allen Wrench by alternating half turns until the potentiometer is secured Attach the potentiometer housing with the 4 40 flat head screws provided and tighten snugly with a Phillips screwdriver The strain relief pigtail from the potentiometer assembly should slide into the slot in the housing NOTE Once the screws for the bracket have been tightened perform the 120 calibration process defined below Replace housing and reinstall push rivets Sec 8 3 3 Calibration of the 120 position NOTE The calibration process described below is to be performed with the Thigh Support Adjustment set at its lowest position Failure to properly position the thigh support will make the distance adjustment of 1 1 4 difficult an may possibly damage the CPM unit With the power on start the CPM into full 120 flexion Stop the carriage Position the ruler onto the unit to measure the distance between the yoke and the end of the extrusion aluminum rail Move the yoke by turning the pulley until the yoke is 1 1 4 from the back of the extrusion If the display reads 1
21. d End Replacement Kit 71230 ii Brush Rod Replacement Kit 71240 S Handle Replacement Kit 71250 a Optical Sensor Replacement Kit 71270 ea Motor Assembly Replacement Kit 71280 a Transformer Replacement Kit 71290 76520 Controller Replacement Kit 71300 76522 Power Switch Replacement Kit 71310 ne Footplate Assembly Replacement Kit 71330 a Housing Replacement Kit 71480 76521 Electronics Upgrade Package 73616 not required SECTION 8 1 FOR USE WITH KIT NUMBER 71160 Tools required Small Flathead Screwdriver Sec 8 1 1 Retaining Ring Pliers PULLEY REPLACEMENT INSTRUCTIONS 3 32 Allen Wrench To remove the pulleys and belts 1 Switch unit to off and unplug the transformer from the wall 2 Remove the push rivets from the lower end of the unit portion with labeling near power cord by lifting head of rivet with a small screwdriver and remove cover Be sure to place rivets where they will not be lost 3 Remove belts from the large pulley and discard 4 Toremove the large pulley loosen the set screw s with a 3 32 Allen Wrench and remove pulley from lead screw shaft Discard pulley and setscrew s 5 Remove spring washer and discard 6 Remove the 3 belts from the Dual Pulley and discard 7 To remove dual pulley first remove the retaining ring from the pulley shaft with retaining ring pliers Discard pulley 8 Remove nylon washer and wave washers 2 and discard 9 Wipe away any excess residue that may have accumula
22. d and pendant connections If still no display replace pendant If still no display replace P C Board Note If this solves the problem test the original pendant it may be okay Check to see if the settings are locked If locked a dot will appear in the lower right hand corner of the display To remove lock press both the UP and DOWN arrows at the same time Check all connections at the P C Board Replace pendant If still no display replace P C Board Note If this solves the problem test the original pendant it may be okay Check pendant settings Ensure settings are greater than 10 apart Check belts Ensure that no oil has gotten onto the belts If oil is present remove all belts and wipe the clean both the belts and pulleys with alcohol to remove oil Allow the components to dry thoroughly before installing belts Remove the belts and turn each of the pulleys by hand If any of the pulleys do not turn freely this could be the cause of the issue If the Large Pulley does not turn freely inspect the thigh adjustment knobs for alignment the condition of the leadscrew and nut and the amount of slack play in the driveline Also inspect the tightness of the screw at the knee joint If the Dual Pulley Transfer Pulley does not turn freely replace pulley If the motor pulley does not turn freely replace motor Remove the Motor Connector from J3 on the Motor PCB Using a knife blade carefully
23. e CPM unit the flanged bushing on the pulley end will need to be removed First remove the extrusion weather stripping or nylon brushes and discard Place the open end of the 7 16 wrench over the leadscrew against the bushing and gently tap the wrench with rubber mallet until bushing is free of the motor plate Take care not to damage bearings inner race Set bearing aside until reinstallation Untie the calf support from the thigh support and slide the lead screw out of the motor plate Turn the lead screw until it is free of the unit Set the leadscrew aside until reinstallation Remove the two screws securing the rod end ball joints to disconnect the thigh calf supports from the unit Take care not to turn the rod ends as it cause the unit to track improperly when it is re assembled Rotate the calf support 90 degrees and remove it from the unit Place the drive punch into threaded hole to secure nut housing for removal of the screws holding the bushings and rollers Using a 1 8 Allen Wrench remove the screws bushings rollers and housing and discard Wipe off old grease and oil and set aside for later installation If the nut housing is of the newer configuration which has a felt oiling pad installed discard used oiling pad see note below Wipe down yoke area and inside of the aluminum extrusion rail with clean towel to remove all debris from the yoke of the calf support Sec 8 5 2 To install a new nut housing Place o
24. e transformer is of the older configuration and has a black DC power plug where it plugged into the old PCB an adaptor cable will need to be used to connect the transformer to the new PCB Motor J3 P N 1 00060 Revision A 25 Optical Sensor J5 6 Secure each of the controller and potentiometer cables into the housing with a Heyco strain relief 7 Secure the wires into the black wire clips located on either side of the new motor PCB and snap clips closed 8 Once the PCBs are completely installed calibration of the Flexmate K500 Knee CPM will be required Calibrate the CPM unit per the instructions in Sections 7 1 and 7 2 2 of this manual page 6 and 7 9 Once the calibration process has been completed successfully place the smaller portion of the main housing into place and secure with the push rivets removed at the beginning of this process P N 1 00060 Revision A 26 8 15 Miscellaneous Part List Description P N Bag 12 x 20 Poly 2 Mil 2 00410 Belt K500 070 x 10 9 16 83A 7 03021 Belt K500 110 x 11 1 4 83A 7 03281 Box Flex Mate K 500 2 01010 Bubble Wrap 1 8 2 01060 Brace S Shape 8 01520 Bushing 375 x 257 x 215 SS 8 01650 Bushing 375 x 201 x 90 7 01891 Bushing 0 5 OD x 281 ID x 944 L 8 01390 Bushing 312 X 220 x 26L 8 01600 Bushing Goniometer Attachment 8 15097 Bushing Strain Relief Right Angle Heyco 7 01951 Bushing Strain Relief 250 Heyco 7 01970 Cable Tie 4 5 00290 Clip Iglide 375
25. e voltage clockwise to decrease the voltage Press Start Stop button again to turn on the motor The unit will start flexing Stop the motor and start again The unit will start extending and when it reaches 10 it will reverse and begin flexing When the unit is flexing and 8 appears on the keypad stop the motor Adjust R1 so that the Voltmeter shows a reading of 0 425 0 002 Volt As with the R1 adjustment turn the trim pot counter clockwise to increase the voltage clockwise to decrease the voltage With these adjustments CPM must cycle without reversal when loaded with a 40 pound weight Do not re adjust these limits if reversal occurs Be sure the unit is properly aligned since misalignment would cause excessive surge currents during start ups and result in motor reversal Also make sure the track is properly oiled Excessive friction may also cause motor reversal P N 1 00060 Revision A 8 Section 8 0 SERVICING AND REPAIR INSTRUCTIONS This section includes the instructions that are contained in the repair kits Section 8 0 1 AVAILABLE KITTED PARTS LISTS Kit Description Kit Part Number indicates kit is universal in use Serial Number 1XXXX Serial Number 2XXXX Softgoods Pad Set K500 06490 ea Pulley Replacement Kit 71160 re Bearing Replacement Kit 71170 ee Potentiometer Replacement Kit 71190 76524 Lead Screw Replacement Kit 71200 mart Nut Housing Replacement Kit 71205 oe Membrane Switch Replacement 71220 aoe Ro
26. ed to the board On the Fig 3 PCB there are 2 variable resistors R5 R6 On the Fig 4 UL PCB there are 3 R1 R6 R5 section 7 CALIBRATION PROCESSES FOR THE FLEX MATE K500 KNEE CPM Sec 7 1 RANGE LIMIT CALIBRATION For the calibration Range Limit the CPM unit is to be plugged in and turned on The thigh support of the carriage must also be set at its lowest setting below 35 on the scale This process is for either the older or current model boards During the process of repairing and reinstallation of a potentiometer calibration will be required If in the case of a broken wire to the potentiometer the display will give a false reading to what the physical angle of the carriage actually is This reading will normally be evident with a display reading of less than 10 To repair and recalibrate the potentiometer follow this process Remove the 3 Goniometer cover screws and cover Check the rear of the Goniometer for any broken wires If there are multiple wire disconnected from the potentiometer re solder the wire to the posts indicated in the Fig 5 P N 1 00060 Revision A 6 NOTE Should the wires of the potentiometer break and require to be soldered onto the post assure that the wires are attached to the proper post of the potentiometer See figures 5 and 6 WIRING DIAGRAM DEFINITION On the side of the Potentiometer is a wiring diagram When viewing the components as indicated in the Fig 6 photo the numbers of the d
27. ench NOTE Due to modifications of the CPM housings there are different processes for the removal and reinstallation of the transformer into the housing The first determining factor is the type of strain relief that is installed into the unit being worked on The simplest means is to review the serial number of the CPM unit For all serial numbers beginning with the number 1 kit number 71290 would be used This kit incorporates a HEYCO 90 strain relief that is installed into an elongated hole For CPM serial numbers beginning with 2 kit number 76520 would be used This kit incorporates a molded 90 strain relief that is fitted into a slot on the lower housing There are also two 2 motor PCBs in use The first that will be in use on most units with a serial number starting with 1 unless the motor PCB has been changed is a DC power plug that is cylindrical in shape The second motor PCB will have a white flat power connector with a locking clip to secure it to the PCB This 2 PCB may be found in some units with a serial number beginning with 1 if the unit has had its PCB replaced For these units that have had the board changed kit number 71290 also includes a jumper to connect the DC plug to the PCB 8 12 1 To Remove the existing Transformer 1 Switch unit to off and unplug the transformer from the wall 2 Remove the push rivets from the lower end of the unit portion with labeling near power cord b
28. ep 9 5 Separate extrusion weather stripping brushes with fingers and place drive punch against flanged bushing Gently tap with rubber mallet until bearing is free from the motor plate Remove old bearing from lead screw and discard 6 Toremove the thrust bearing move the upper housing to reduce interference while working Sec 8 2 2 Configuration One Cotter Pin Collar Removal 7 Toremove the cotter pin from the leadscrew rotate lead screw shaft to expose the tail ends of cotter pin and bend ends with the pliers until straightened Rotate shaft to expose the opposite end of the pin and pull it out of the collar Set aside for later installation 8 Remove the collar and set it aside for later installation Remove the thrust bearing and thrust bushing and discard P N 1 00060 Revision A 10 Sec 8 2 3 Configuration Two Nylon Lock Nut 9 Toremove the nylon lock nut from the leadscrew place the 7 16 open end wrench onto the nut Grasp the large pulley to secure the leadscrew in place and remove the nut Place the nut aside and discard the spring washer if any are installed 10 Perform Step 4 amp 5 at this time to remove the large pulley and flange bearing from the pulley end of the lead screw 11 To remove flanged bushing separate extrusion weather stripping brushes with fingers and place drive punch against flanged bushing Gently tap with rubber mallet until bearing is free from the thrust bearing plate Remove old bear
29. g into place with rubber mallet if necessary 2 Reinstall the large pulley and spring washers assuring the set screw is aligned with the flattened key way hole on the lead screw shaft 3 Install 2 setscrew if applicable and tighten securely 4 Install belt s between the dual pulley and the large pulley Sec 8 2 5 FLANGE BEARING THRUST BEARING INSTALLATION 5 Place a flange bearing onto lead screw shaft as so the flanged portion of the bearing is away from unit Press bearing into the thrust bearing plate until the flange is flush with the plate Gently tap bearing into place with rubber mallet if necessary 6 Remove pre greased thrust bearing from plastic bag and slide onto lead screw shaft Assure that the thrust bushing is properly installed into the thrust bearing Sec 8 2 6 Installation of Configuration One Collar Cotter Pin 7 Once the thrust bearing is installed onto the leadscrew place collar onto shaft and align the thru hole with the hole in the lead screw shaft and insert cotter pin 8 Using slip lock pliers bend the ends of the cotter pin until it is flush with the collar Sec 8 2 7 Installation of Configuration Two Nylon Lock Nut 9 Once the thrust bearing is installed onto the leadscrew place the two spring washers onto the shaft and hand thread the nut onto the leadscrew P N 1 00060 Revision A 11 10 Grasp the large pulley with one hand and tighten the nylon nut with the 7 16 wrench To assure
30. g of the calibration settings Below are 2 examples of the clips that can be used P N 1 00060 Revision A 7 Sec 7 2 1 Calibration of older model Motor PCBs fig 3 A To set the reversing load limit bring the CPM to the 10 position then find TP2 TP3 and R6 on the Motor PCB Using a voltmeter attach the positive lead to TP2 the negative lead to TP3 and set the voltmeter for volts With CPM power ON the meter should read about 450 volts 450 mV The CPM should be able to lift about 40 pounds before the load reverse limit is activated If it fails to lift the weight adjust R6 counter clockwise to increase the voltage and the weight is not activating the load reverse limit WARNING Under no circumstances should the R6 voltage setting exceed the maximum of 450 volts at the 10 position Exceeding the 450v rating may damage the motor and motor driver over time Sec 7 2 2 Calibration of Current model Motor PCBs fig 4 Set the Extension Limit at 10 position and Flexion Limit at 120 positions on the controller Locate TP2 TP3 R1 and R6 on the Motor PCB Attach the positive lead of a Voltmeter to TP2 and the negative lead to TP3 Press the Start Stop key on the keypad to start the motor Stop the unit by pressing the Start Stop key when the unit is extending and 8 has been reached Adjust R6 so that the voltage on the Voltmeter reads 0 125 0 002 Volt Turn the trim pot counter clockwise to increase th
31. grease from Lubrication Technology Inc 310 Morton Street Jackson Ohio 45640 740 286 2644 2 3 in 1 Oil or equivalent sewing machine oil P N 1 00060 Revision A 3 SECTION 2 BASIC TROUBLESHOOTING DURING WARRANTY PERIOD No pendant display Check that the wall outlet has power Check power switch on Pendant displays Err Turn power off wait 5 seconds and turn power back on Pendant adjustments inoperative but Check all connections at the P C Board display is on Unit will not start or it starts then stops Check pendant settings Check belts Cannot change pendant settings Refer to User s Manual regarding locking feature NOTE If the above solutions do not work or for other problems not listed call KLC Services Inc Any actions taken other than those listed above will void the Warranty SECTION 3 No pendant display Pendant adjustments inoperative but display is on Unit will not start or it starts then stops Cannot change pendant settings Angle does not appear to read correctly on pendant Loud grinding screeching sounds present when in TROUBLESHOOTING OUT OF WARRANTY PERIOD Check that the wall outlet has power Check power switch on Use a multi meter to check voltage before and after switch If no voltage before switch replace transformer See voltage chart Pg27 If voltage before but not after switch replace switch If voltage after switch check all P C Boar
32. hers and the 28 Nylon Locking Nut onto the lead screw and tighten the nut up to the nylon insert 3 Place the flange bearing onto the lead screw and press in flush to the motor plate Gently tap the outer race of the bearing in with the rubber mallet if necessary Take care not to damage the inner race 4 Reinstall the large pulley by realigning the setscrew to the hole notch in the leadscrew The pulley should be flush with the end of the lead screw If the pulley being installed if the gray grooved pulley be sure to install the retaining setscrew into the large pulley and tighten firmly 5 Place the open end 7 16 wrench onto the Nylon Locking Nut Grip the large pulley firmly and tighten the nut It is recommended that approximately 1 16 of gap play be left in the driveline to reduce binding of the leadscrew 6 Reinstall the belts between the dual and large pulleys 7 Remove lightweight rope from unit 8 Plug transformer into wall and start the unit to assure proper tracking of the upper assembly If the leg supports are tracking properly tighten rod end screws 9 Ifthe assembly is not tracking properly remove screw on opposite side of the direction of the tracking and turn the rod end out by 1 2 turn and reinstall screw Allow unit to run 2 3 cycles and verify if the unit is tracking properly If correct tighten rod end screws If not repeat this step until proper tracking is achieved 10 Install brushes and rods b
33. hing The bushing should be located approximately 1 2 inches back from the stripped portion of the wire Direct the transformer cable away from the switch 15 Connect the two flag connectors to the power switch P N 1 00060 Revision A 22 16 Connect DC plug to the PCB and secure it with the 4 cable tie NOTE For connecting to a newer PCB plug the DC plug onto the jumper that was included in kit number 71290 Plug the other end of the jumper into the PCB For units with serial numbers beginning with 2 17 Slip the molded strain relief into its slot on the lower housing Be sure to direct the transformer cable away from the switch as to not interfere with it s accessibility or operation 18 Secure the ring terminal on the green ground wire to the frame using the screw saved in Part 1 NOTE _ If it was necessary to remove the large pulley to remove the screw replace it at this time Assure that the setscrew is aligned properly with the mounting hole on the leadscrew Replace the belts accordingly 19 Secure wires into the wire clip 20 Secure wires to the PBC power to the frame of the CPM 21 Replace housing and secure with push rivets SECTION 8 13 HOUSING REPLACEMENT INSTRUCTIONS For use with kit number 71480 or kit number 76521 Tools required 0 Phillips Screwdriver Pliers or strain relief pliers Small Flathead Screwdriver Diagonal Cutters NOTE There are two 2 different configurations of the CPM
34. housings for the Flexmate K500 The difference between the configurations is due to the manner of securing the cables for the transformer controller and potentiometer The first configuration kit number 71480 is used for units with a serial number beginning with 1 uses the HEYCO strain relief to secure the cables passing through the housing The second configuration kit number 76521 is for units with a serial number beginning with the number 2 and incorporates a molded strain on each cable that lock onto special kKeyways of these housings 8 13 1 To remove the existing housing 1 Switch unit to off and unplug the transformer from the wall 2 Remove the push rivets from both halves of the upper housing of the unit by lifting head of rivet with a small screwdriver remove and discard rivets 3 Open wire clips with the small flat head screwdriver and remove wires from clips 4 Disconnect the connectors from the headers on the motor PCB Controller J1 Transformer J2 Motor J3 Potentiometer J4 l Optical Sensor J5 Note Cut cable tie securing the DC plug on the transformer ee 5 Remove the strain relief bushings or molded strain relief from the housing sections with strain relief pliers and discard the bushings To remove the molded controller and potentiometer relief grasp the relief near the base with the strain relief pliers and twist counter clockwise 90 and pull relief from housing Caref
35. iagram will be aligned with the proper post The number wire combinations are Post 1 White Post 2 Black Fig 6 Post 3 Red On the joint coupling remove the first setscrew and tighten the second one then replace the first setscrew This will insure the coupling is tight to the shaft Using the control pendant move the leg carriage until the thigh and calf support bars on either side of the hinges align in a straight line This can be checked visually or with a straight edge Loosen the 2 screws using a 3 32 Allen wrench that hold the Goniometer in position Rotate the Goniometer until the control pendant displays reads 0 Tighten the 2 screws Start the CPM in flexion and stop it when the rear of the calf support nut yoke is 1 1 4 1 8 from the rear end of the extrusion figure 7 End of extrusion Rear of yoke is 1 1 8 from end of extrusion Fig 7 Il Check the control pendant display if it does not read 120 then adjust R5 on the Motor PCB with a small screwdriver until it does Make sure all screws and set screws are tight and replace the Goniometer cover Check 10 again if it does not read 10 change the Motor PCB Sec 7 2 LIMITS OF REVERSING LOAD In order to properly calibrate the Reversing Load Limits of the Flex mate K500 Knee CPM and digital multi meter should be used It is also recommended that probe clips be utilized to ensure proper connectivity and allow easier adjustin
36. iler felt into a small cup and saturate with the supplied oil Gently squeeze felt to remove excess oil Insert the oiler felt into the recess inside the nut housing Install the orange ACME nut into housing taking care not to roll the oiler felt during this process Install the housing into the calf support yoke assuring that the oiler hole is to the top front of the support Slide a washer bushing and a roller onto each of the two 10 32 x 5 8 button head screws P N 1 00060 Revision A 16 5 Place a small drop of serviceable lock tight onto the ends of each screw 6 Insert the assemblies through the holes in the yoke and secure tightly to the nut housing NOTE Assure that the ACME nut is not locked in place by the screws If the nut cannot move in a reasonably free motion it may cause binding of the leadscrew or premature failure of the coating on the leadscrew 7 Reinstall thigh calf support into unit 8 Reinstall the screws that connect the thigh calf support to the unit Do not tighten screws completely at this time Sec 8 5 3 Installation of the Leadscrew 1 Insert lead screw into the ACME nut through the motor plate and thread in approximately 4 Pull the calf and thigh supports back to into flexion position and secure with the lightweight rope Continue threading the lead screw in until it is extended through the flanged bushing in the thrust plate 2 Reinstall the thrust bearing thrust bushing 2 spring was
37. ing 1 Switch unit to off and unplug the transformer from the wall P N 1 00060 Revision A 18 3 4 Remove the push rivets from the front half of the upper housing of the unit by lifting head of rivet with a small screwdriver remove smaller cover and set aside Be sure to place rivets where they will not be lost Remove the belts from the large pulley and set aside To remove the large pulley loosen the set screw with a 3 32 Allen wrench and pull the pulley and spring washers from the lead screw and set aside Grasp end of weather stripping and pull perpendicular from unit to remove Sec 8 8 2 To remove the existing brushes rds Switch unit to off and unplug the transformer from the wall Remove the push rivets from the front half of the upper housing of the unit by lifting head of rivet with a small screwdriver remove smaller cover and set aside Be sure to place rivets where they will not be lost Remove the belts from the large pulley and set aside To remove the large pulley loosen the set screw with a 3 32 Allen wrench and pull the pulley and spring washers from the lead screw and set aside With a flat screwdriver pry open the very ends of the extrusion if they have been crimped close Grasp end of brush with slip lock pliers and extract from end of unit Slide rod out of unit from end Sec 8 8 3 To replace the Brush Rod Assembly Insert the brush into the extrusion from the end nearest the pulley system In
38. ing from lead screw and discard Sec 8 2 4 To install the new bearings FLANGE BEARING PULLEY INSTALLATION NOTE As with the Thrust Bearing Removal Installation configurations there are 2 different pulley configurations and 3 different mounting hardware configurations for the large pulley If you are using the previous pulley leadscrew that were installed before the replacement of the bearings determine which configuration it is and follow the stated installation process for that configuration If you are installing either the pulley kit Kit No 71160 or the leadscrew kit Kit No 71200 separately there may be alignment and attachment issues It is recommended that if either of these kits are being replaced that the associated kit also be installed The pulley configurations are as follow 1 Black toothed pulley w flat toothed belt 2 Grey grooved pulley w round belts The mounting configurations and the associated pulley descriptions are as follow Pulley Configuration Fastener Type Leadscrew Mount 1 Black pulley toothed belt 6 32 x 1925L set screw Flat slot 2 Grey grooved pulley 10 24 x 625L set screw Chamfered Hole 10 24 x 50L full dog set screw 1 8 hole obsolete component no longer offered in repair kits 1 Place a flange bearing onto lead screw shaft as so the flanged portion of the bearing is away from unit Press bearing into the thrust bearing plate until the flange is flush with the plate Gently tap bearin
39. is suggested that if the original non oiling housing is evident that this assembly be replace with kit number 71205 Nut Housing Assembly P N 1 00060 Revision A 14 9 Wipe down nut housing yoke area and inside of the aluminum extrusion rail with clean towel to remove all debris from the yoke of the calf support Sec 8 4 2 Installation of the Leadscrew NOTE Note that if the pulley is black and has teeth such as a gear and the belt being removed also has teeth this pulley is of the original configuration and cannot be used with the new leadscrew If this is the case than you must replace this pulley with kit number 71160 Be aware this new pulley system incorporates the use of 3 round belts that will run from the dual pulley to the large drive pulley It also uses 3 thinner round belts that run between the dual pulley and the motor pulley If the belt of the 2 set between the motor and the dual pulley is flat then the motor assembly kit number 71280 must be changed also 1 Insert the orange ACME nut into the nut housing If the nut housing has a built in oiling felt assure that the felt does not get folded Apply lightweight machine oil to the felt to thoroughly saturate the felt 2 Insert new lead screw into the ACME nut through the motor plate and thread in approximately 4 Pull the calf and thigh supports back to into flexion position and secure with the lightweight rope Continue threading the lead screw in until it is ex
40. ith a relative humidity between 10 and 100 non condensing The FLEX MATE K500 can operate between 50 F to 95 F 10 C to 35 C under the same humidity levels and 700 hPa to 1060 hPa atmospheric pressure Any service requirements beyond the scope of this service manual are to be performed by the factory or an authorized service repair representative Units returned to the factory for repair are not to be modified Such modification include but are not limited to a modifications that restrict the accessibility to critical components b modifications that bypass any safety features originally designed into the Flex Mate K500 Knee CPM unit c or modifications that may cause further damage to the Flex Mate K500 Knee CPM unit or the end user Replacement of any modified components will be made at the customer s expense P N 1 00060 Revision A 2 FLEX MATE K500 WARRANTY KLC Services Inc warrants the Flex Mate K500 to be free from defects in materials and workmanship under normal and proper use under the direct supervision of a licensed health care practitioner during the warranty period of one year commencing from the date of purchase Date of Purchase will be the date your payment is processed by our Bank and funds are received by KLC Services Inc This warranty extends only to the original purchaser and is not transferable to anyone who subsequently purchases leases or otherwise obtains the K500 from the original purchaser This Warr
41. l for contact between the wheel screw and sidewall If contact has been made Remove upper carriage assembly as dictated in Section 8 5 Nut Housing Replacement Instructions and ensure the proper assembly Inspect the condition of the leadscrew If the operational portion of the leadscrew appears dry apply oil to the oiler felt and leadscrew If the operational surface of the leadscrew appears to be dry but shiny the Teflon coating has been worn off It is recommended that the leadscrew is replaced at this time Powdery substance Determine area of development developing under If under the foot end of the unit and the color is whitish inspect the motor unit pulleys and belts for excessive wear Replace if necessary If under user end and the color is reddish brown or black inspect the rod ends Replace if necessary All other problems Call KLC Services Inc for assistance Section 4 The Flex mate K500 Motor PCB Due to modifications in both the electronic hardware and software for the K500 Knee CPM there are 2 different calibration processes Determination of the Motor PCB will be required to employ the correct calibration process The earlier model boards fig 3 calibration process requires adjustment to R5 for Range Limit and R6 for Load Limit The load limit on the earlier is bi directional which means one setting of both flexion and extension Calibration adjustments for the current model board fig 4 includes R5 for the R
42. mages Purchaser understands acknowledges and agrees that repair or replacement as applicable under the warranty services described herein are your sole and exclusive remedies with respect to any breach of the warranty set forth herein SECTION 1 ROUTINE MAINTENANCE SCHEDULE NOTE The bearings that are located at each end of the leadscrew are sealed and do not require oiling Before each use Every Month Every 3 Months To be performed by To be performed by user To be performed by authorized service user or service or service personnel personnel personnel Inspections General condition General condition Frayed power cord Housing integrity Check belt wear Grease Grease the outside edges of Thrust Lubrication Bearing at lower end of Drive Screw Use a white lithium based grease Oil Lubrication Apply 3 drops of oil to Apply 3 drops of oil to The oiling felt of the nut housing is to be NOTE Never the oiling felt located in the oiling felt located in inspected and replaced if necessary lubricate any the nut housing the nut housing Using oil add a drop to the Knee Joints belts or pulleys Rod Ends S Brackets and Clevis with oil connections Cleaning Clean housing amp leg Wipe the belt s amp both Wipe pulleys with alcohol and replace carriage with a mild pulleys with alcohol and belt if required soap solution and dry allowed to dry thoroughly thoroughly before installing belts 1 Christo Lube
43. ools required Rubber Mallet Slip Lock Pliers 4 Drive Pin Punch Diagonal Cutters Retaining Ring Pliers 3 32 Allen Wrench Small Flathead Screwdriver 7 16 Open End Wrench Note Due to upgrades in the system that allow for better adjustment of the leadscrew there are two 2 leadscrew configurations To determine which configuration is installed into the unit being repaired examine the fastening system for the thrust bearing This is the end of the leadscrew opposite the pulley and belts Configuration One will have a collar and cotter pin attachment and Configuration Two will incorporate a 14 28 nylon lock nut The removal and installation instructions for both are detailed below obsolete component no longer offered in repair kits Sec 8 2 1 To remove the bearings 1 Switch unit to off and unplug the transformer from the wall 2 Remove the push rivets from the upper housing of the unit by lifting head of rivet with a small screwdriver remove smaller cover and set aside Be sure to place rivets where they will not be lost 3 Remove belts from the large pulley and set aside 4 Remove the large pulley loosening the set screw with a 3 32 Allen Wrench also remove spring washer and set them aside Perform steps 4 amp 5 at this time only if the Configuration One attachment cotter pin collar is in use Otherwise leave this pulley flange bearing on the leadscrew to assist in the removal of the nylon lock nut defined is St
44. ost 4 There are 2 different configurations for the manner in which the Thrust Bearing is secured to the lead screw Collar and cotter pin or a 4 28 Nylon Locking Nut To determine this examine the attachment at the opposing end of the leadscrew from the pulley belt assembly e For units with the collar cotter pin attachment method Remove the thrust bearing and collar assembly by rotating lead screw to expose the tail ends of the cotter pins and cut ends off with diagonal cutters Rotate lead screw and remove remainder of cotter pin by pulling with the slip lock pliers Discard the thrust bearing collar and cotter pin e For units with the 28 Nylon Locking Nut Remove the thrust bearing assembly by placing a 7 16 open end wrench onto the nut Hold the large pulley firmly and remove the nut from the leadscrew Discard the used Nylon Locking Nut 5 Remove the belts from the large pulley and set aside To remove the large pulley Remove the retaining set screw if present and then loosen the set screw with a 3 32 Allen wrench and pull the pulley and spring washers from the lead screw and set aside NOTE When removing the pulley please note that if the pulley is black and has teeth such as a gear and the belt being removed also has teeth this pulley is of the original configuration and cannot be used with the new leadscrew If this is the case than you must replace this pulley with kit number 71160 Be aware this
45. rew 7 Reinstall the belts between the dual and large pulleys 8 Remove lightweight rope from unit 9 Plug transformer into wall and start the unit to assure proper tracking of the upper assembly If the leg supports are tracking properly tighten rod end screws 10 If the assembly is not tracking properly remove screw on opposite side of the direction of the tracking and turn the rod end out by 1 2 turn and reinstall screw Allow unit to run 2 3 cycles and verify if the unit is tracking properly If correct tighten rod end screws If not repeat this step until proper tracking is achieved 11 Install brushes and rods by sliding a brush into each of the grooves on the upper lip of the aluminum extrusion 12 Slide the rods in behind the brushes to secure the brushes in place 13 Replace both sections of the upper housing and reinstall the push rivets SECTION 8 5 NUT HOUSING REPLACEMENT INSTRUCTIONS For use with kit number 71205 Tools required Rubber Mallet Slip Lock Pliers Diagonal Cutters Retaining Ring Pliers 1 64 Allen Wrench 3 32 Allen Wrench 1 8 Allen Wrench 5 32 Allen Wrench Small Flathead Screwdriver 2 Foot Of Light Weight Rope or String P N 1 00060 Revision A 15 0 Phillips Screwdriver 7 16 Open End Wrench 10 11 12 Sec 8 5 1 To remove the existing nut housing Turn unit on and start into complete flexion 120 Using the lightweight rope or string secure calf support to thigh suppor
46. sert the metal rod into the extrusion behind the brush to push the brush forward towards the center of the unit Crimp the ends of the extrusion to secure the brushes Replace housing onto unit and secure with push rivets SECTION 8 9 HANDLE REPLACEMENT INSTRUCTIONS For use with kit number 71250 Tools required 2 Phillips Screwdriver Flathead Screwdriver 3 Sec 8 9 1 To remove the existing Handle Switch unit to off and unplug the transformer from the wall Remove caps at the end of the handle by prying with a flathead screwdriver NOTE These caps may not be present on some units due to a change in the handle Remove screws with a 2 Phillips screwdriver Remove handle from CPM unit Sec 8 9 2 To replace the Handle Place handle between mounting points on unit Place mounting hardware over ends of handle as so the tabs on hardware are set into offset hole on the units cover Secure the mounting hardware with a 2 Phillips screwdriver P N 1 00060 Revision A 19 SECTION 8 10 OPTICAL SENSOR REPLACEMENT INSTRUCTIONS For use with kit number 71270 Tools required 1 Phillips Screwdriver Small Flathead Screwdriver Sec 8 10 1 To remove the existing Optical Sensor 1 Switch unit to off and unplug the transformer from the wall 2 Remove the push rivets from the lower end of the unit portion with labeling near power cord by lifting head of rivet with a small screwdriver and remove cover Be sure to place rivets where
47. t Switch unit to off and unplug the transformer from the wall Remove the push rivets from both halves of the upper housing of the unit by lifting head of rivet with a small screwdriver remove smaller cover and set aside Be sure to place rivets where they will not be lost There are 2 different configurations for the manner in which the Thrust Bearing is secured to the lead screw Collar and cotter pin or a 4 28 Nylon Locking Nut To determine this examine the attachment at the opposing end of the leadscrew from the pulley belt assembly e For units with the collar cotter pin attachment method Remove the thrust bearing and collar assembly by rotating lead screw to expose the tail ends of the cotter pins and straighten the ends with pliers Rotate lead screw and remove the cotter pin by pulling with the slip lock pliers Set thrust bearing collar and cotter pin aside for later installation e For units with the 28 Nylon Locking Nut Remove the thrust bearing assembly by placing a 7 16 open end wrench onto the nut Hold the large pulley firmly and remove the nut from the leadscrew Set the Nylon Locking Nut aside for later installation Remove the belts from the large pulley and set aside To remove the large pulley Remove the retaining set screw if present and then loosen the set screw with a 3 32 Allen wrench and pull the pulley and spring washers from the lead screw and set aside To remove leadscrew from th
48. ted on both shafts Sec 8 1 2 To install the new pulleys and belts 1 Place small spring washer onto pulley shaft P N 1 00060 Revision A 9 2 Place dual pulley onto pulley shaft The larger portion of the pulley is to be next to the motor plate Using the retaining ring pliers install the retaining ring onto the shaft assuring the ring is seated into the groove on the shaft 3 Install the three smaller diameter belts to the motor pulley and the larger portion of the dual pulley 4 Place nylon washer and wave washers 2 onto lead screw shaft 5 Install the large pulley onto the lead screw shaft When installing assure that the set screw is aligned with the 1 8 diameter hole on the shaft The pulley should be flush with the end of the shaft 6 Install the Full dog setscrew into the pulley and tighten assure that the Full dog point is properly seated into the hole on the shaft Install the setscrew into the pulley and tighten 7 Install the three larger diameter belts to the large pulley and the smaller portion of the dual pulley 8 Replace housing onto unit and secure with push rivets Note This pulley belt system is to be used with units that have a grooved pulley on the motor assembly If the system being repaired has a non grooved pulley then an upgraded motor assembly kit BREG P N 71280 will need to be installed Section 8 2 BEARING REPLACEMENT INSTRUCTIONS For use with kit number 71170 T
49. tended through the flanged bushing in the thrust plate 3 Reinstall the thrust bearing thrust bushing 2 spring washers and the 28 Nylon Locking Nut onto the lead screw and tighten the nut up to the nylon insert For leadscrews that incorporate the use of the collar cotter pin slide the collar onto the shaft and align the small hole to the hole on the leadscrew Insert the cotter pin Rotate the leadscrew to expose ends of the cotter pin Spread the ends of the cotter pins and wrap them back around the leadscrew Assure that the legs of the cotter pin are flat against the shaft If clicking is heard when it is turned on or if the unit freezes in place inspect the legs of the pin to assure that they are not interfering with the housing or frame of the CPM unit 4 Place the flange bearing onto the lead screw and press in flush to the motor plate Gently tap the outer race of the bearing in with the rubber mallet if necessary Take care not to damage the inner race 5 Reinstall the large pulley by realigning the Full dog setscrew to the 1 8 hole in the leadscrew The pulley should be flush with the end of the lead screw Install the 10 24 x retaining setscrew into the large pulley and tighten firmly 6 Place the open end 7 16 wrench onto the Nylon Locking Nut Grip the large pulley firmly and tighten the nut It is recommended that approximately 1 16 of gap play be left in the driveline to reduce binding of the leadsc
50. ully remove the wires that are threaded through the openings To remove the strain relief for the transformer slide the relief from its slot 6 Discard both sections of the upper housing 7 Unscrew the ground wire on the transformer from the frame and retain screw for reinstallation P N 1 00060 Revision A 23 8 Remove the Motor PC Board from its mountings Set screws aside for reinstallation of board 9 Using the small diagonal cutters clip the wire tie that is securing the switch into the housing 10 Disconnect the flag connectors from the power switch With the diagonal cutters cut the cable tie that is securing the switch to the housing and remove the switch from the housing Set aside the switch for later installation 11 Remove handle by removing the flat head screws with the Phillips screwdriver And set aside for later installation 12 Turn the Flex Mate unit upside down and remove the 4 screws that secure the housing to the frame Discard lower housing 8 13 2 To install a new housing 1 Place new lower housing onto up turned unit and align the holes to the frame Install the 4 8 32 x 318 screws to secure the lower housing 2 Turn the unit right side up and install the power switch into the unit as so the on position will be next to the power cord Secure the power switch into the housing with a 4 cable tie 3 Position the PC board into the unit as so the main power connection is opposite the motor
51. y lifting head of rivet with a small screwdriver and remove cover Be sure to place rivets where they will not be lost 3 Disconnect the flag connectors from the power switch 4 For units with serial numbers beginning with 1 5 Clip cable tie securing the DC plug to the motor PCB and unplug 6 For units with serial numbers beginning with 2 and S N 1XXXXX units with a newer motor PCB N Unplug the power connector from the PCB Oo Using the adjustable wrench unscrew the ring terminal on the green ground wire from the frame Retain screw for reinstallation NOTE It may be necessary to remove the large pulley from the CPM in order to remove the ring terminal If this is required remove the belts from the pulley and set aside Using a 3 32 Allen wrench remove the 1 setscrew from the pulley Back the 2 setscrew out approximately 1 4 to release the pulley from the leadscrew Set the pulley aside for reinstallation 9 Open wire clip to release wires 10 For units with serial numbers beginning with 1 11 Remove strain relief bushing from the housing and pull cord through Discard old transformer 12 For units with serial numbers beginning with 2 13 Lift the molded strain relief out of its slot in the housing and discard the transformer 8 12 2 To Replace the Transformer For units with serial numbers beginning with 1 14 Insert the wire through the housing and secure with the strain relief bus
52. y sliding a brush into each of the grooves on the upper lip of the aluminum extrusion 11 Slide the rods in behind the brushes to secure the brushes in place 12 Replace both sections of the upper housing and reinstall the push rivets SECTION 8 6 MEMBRANE SWITCH REPLACEMENT INSTRUCTIONS For use with kit number 71220 Tools required 1 Phillips Screwdriver Small Flathead Screwdriver Sec 8 6 1 To remove the existing membrane switch 1 Pull label off of the back of the controller pendant and discard 2 Remove screws using a 1 Phillip screwdriver keep screws for re assembly of pendent P N 1 00060 Revision A 17 3 Disconnect the existing membrane switch from the controller circuit board 4 Peel membrane switch from front controller housing and discard If necessary use a small flathead screwdriver to lift the edge of the switch Sec 8 6 2 To replace the membrane switch 1 Peel backing from new membrane switch and position onto front controller housing Be sure to thread connector through slot in housing before applying switch 2 Connect switch to circuit board 3 Replace circuit board back into front housing assuring that the strain relief is inside case and the wires are not interfering with alignment of the housing bosses through the circuit board 4 Place back controller housing and secure with screws 3 5 Peel backing off of controller back label and position onto the back of the controller housing 6 Peel