Home
        While in the SETUP menu normally the setup is for viewing only. To
         Contents
1. 2     3     4     5     6     7     xITRANSFER    Quick Start Guide  There is a User Manual in PDF format on the enclosed USB memory stick     please  read that first     Insert a USB memory stick into the xITRANSFER    unit  Remove the small pink plastic stop from the  xITRANSFER    unit On Off switch and turn the unit on     After a couple of seconds the xITRANSFER    will display its main menu  Press 4 for SETUP  Follow the  instructions in the User Manual to set and name the first machine  Hint  make sure to match the machine   s  baud rate  For 90  of the controls ISO code  LF only and XON XOFF handshake will work fine  At the  end press the ENT key to get back to the Main Menu     Select 2 for a Machine to USB transfer  Select the single dot  press ENT and name the incoming file for  simplicity 123 and press ENT  read the User Manual how to    rotate    for letters  at the end press ENT again   The xITRANSFER    unit is now ready to receive a file  Now perform a    Send    or    Punch    operation at the  machine tool  As the G code program is being sent  the second line of the xITRANSFER    unit   s LCD  display shows the incoming lines  Once the transfer ends  the LCD display will show the last received  characters  LF signals line feed and CR signals carriage return characters    Press ESC key to display the  name and number of characters of the just received program then press ESC again     Now at the CNC control rename the just punched program and set the control t
2. he xITRANSFER    unit will display    Receiving done    message  Press ESC key to display    the name and number of characters of the just received program then press ESC again to go back to the  Main menu     Technical support   service  richmondmachine com  or 586 727 3501       
3. ick CNC control  1  Step 1  is same as for FANUC  2  Step 2  is same as for FANUC  just make sure that a setup with MZK code is selected   3  On the xITRANSFER    unit at the Main Menu select item 1   arrow down to the program to be sent and  press ENT key  The unit will say    Sending    but nothing else will happen yet  Now at the control go into the  CMT menu  press    LIST CMT CONTENT     followed by START  After few seconds the control will list the  available work numbers  Now you can select CMT  gt NC  LOAD  operation followed by START and the  control will read the listed work number s   Note here  that you can also execute a COMPARE operation  using the same steps as for LOAD   B  From Control to USB memory stick  1  Step 1  is same as for FANUC  2  Step 2  is same as for FANUC  just make sure that a setup with MZK code is selected   3  Select 2  for a Machine to USB transfer  Select the single dot  press ENT and name the incoming file  for  numbers just press the key  read the User Manual how to    rotate    for letters   Once the name is done  press  ENT again   You can also key down and press the ENT over an existing program to overwrite it   The  xITRANSFER    unit is now ready to receive a file  Now go to the CMT menu at the control  INPUT the  work number s   press the NC  gt CMT  SEND  operation and press START  As the conversational program  is sent  the second line of the xITRANSFER    unit   s LCD display shows the incoming lines  Once the  transfer ends  t
4. ill show  nothing after turning the unit on  In such a case  1  Turn the unit OFF  2   Connect the charger for about 5 minutes  3  Turn the unit ON   display  should come back and the red charge light should turn on  Charge the unit  like that before using it for at least 10 minutes     after done using it connect  the charger back having the unit ON but the USB key removed until fully  charged     Communicating with a G code control  FANUC or similar   A  From USB memory stick CNC control   1  Plug the xITRANSFER    serial cable into the control RS232 port  make sure that the correct USB memory  stick is inserted into the unit and turn the unit on    2  Press the LIST key on the xITRANSFER    to make sure that the correct setup is selected     press ENT if  the correct setup name is displayed else right left arrow to the correct name and then press ENT   You can  do a fast parameter check pressing the HOME key instead the LIST  but that shows only while the key is  pressed and won   t let to change the setup     3  At the CNC control set the control to receive  Once ready  on the xITRANSFER    unit at the Main Menu  select item 1   arrow down to the program to be sent and press ENT key  The second line of the LCD  display will show the outgoing lines  Once done your CNC control should have and display the just  received program   If there are too many programs on the USB key  you can do a    directory search         please read the User Manual how to do that      B  From Con
5. o receive  Once ready  on the  xITRANSFER    unit at the Main Menu select item 1   arrow down to the just received 123 program and  press ENT key  The second line of the LCD display will show the outgoing lines  Once done your CNC  control should have and display the just received program  You can also take program 123 on the USB  memory stick to your computer and view edit it for example with Notepad     Based on this experience now you can set up the rest of the machines  The similar machines can use the  same setup of the xITRANSFER    unit  You can name a setup in the unit  FANUC  MAZAK  etc     up to  8 characters long  Before sending receiving while at the Main Menu you can select a different setup using  the LIST and the arrow keys     The xITRANSFER    can also drip feed a CNC control if the control itself is capable of doing that  For that  application an xXITRANSFER    per machine is recommended with a permanent hookup  For a permanent  hookup you may remove the 4 AA batteries and connect the xITRANSFER    to its charger all the time     While in the SETUP menu normally the setup is for viewing only  To enable  the change of BAUD rate  etc   you need to type in     while in the SETUP menu    the numbers 147 blindly  This code    unlocks    the    view only    mode  Once you  leave the SETUP menu and re enter it you need to re type this code again   This is to prevent accidental parameter change     If the rechargeable battery is completely depleted  the LCD screen w
6. trol to USB memory stick   1  Plug the xITRANSFER    serial cable into the control RS232 port  make sure that the correct USB  memory stick is inserted into the unit and turn the unit on    Press the LIST key on the xITRANSFER    to make sure that the correct setup is selected     press ENT if  the correct setup name is displayed else right left arrow to the correct name and then press ENT   You can  do a fast parameter check pressing the HOME key instead the LIST  but that shows only while the key is  pressed and won   t let to change the setup     2  Select 2  for a Machine to USB transfer  Select the single dot  press ENT and name the incoming file  for  numbers just press the key  read the User Manual how to    rotate    for letters   Once the name is done  press  ENT again   You can also key down and press the ENT over an existing program to overwrite it   The  xITRANSFER    unit is now ready to receive a file  Now perform a    Send    or    Punch    operation at the  machine tool  As the G code program is being sent  the second line of the xITRANSFER    unit   s LCD  display shows the incoming lines  Once the transfer ends  the LCD display will show the last received  characters  LF signals line feed and CR signals carriage return characters    Press ESC key to display the    name and number of characters of the just received program then press ESC again to go back to the Main  menu     3   Communicating with a Mazak control conversational program  A  From USB memory st
    