1. MITSUBISHI ELECTRIC GOT2000 Series Multimedia Unit User s Manual GT27 MMR Z Set of GT16M MMR Z and GT27 IF2000 Thank you for purchasing the GOT2000 Series Prior to use please read both this manual and detailed manual thoroughly to fully understand the product MODEL GT27 MMR Z U JE MODEL CODE IB NA 0800518 A 1309 MEE 1D7ML3 GRAPHIC OPERATION TERMINAL GoT oo0o0o SAFETY PRECAUTIONS Always read these precautions before using this equipment Before using this product please read this manual and the relevant manuals intro duced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this product In this manual the safety precautions are ranked as WARNING and CAUTION Indicates that incorrect handling may cause hazardous l A WARNING conditions resulting in death or severe injury l Indicates that incorrect handling may cause hazardous l CAUTION conditions resulting in medium or slight personal injury 4 or physical damage Note that the A CAUTION level may lead to a serious accident according to the circumstances Always follow the precautions of both levels because they are important to per sonal safety Please save this manual to make it accessible when required and always forward it to the end user DESIGN PRECAUTIONS CAUTION Do not bunch the
2. power supply cable of the video camera may cause malfunction of the GOT or a programmable controller In this case attach the following line filter to the power supply line of the video camera Recommended line filter TDK Lambda RSHN 2003 or equivalent products To use the Multimedia unit set the controller settings For the settings and system configurations refer to GOT2000 Series Connection Manual Microcomputer MODBUS Products Peripherals for GT Works3 Version 1 For the details of the multimedia function refer to GT Designer3 GOT2000 Help 2 SPECIFICATIONS The following shows the performance specifications of the Multimedia unit The general specifications of the Multimedia unit are the same as those of the GOT For the general specifications of the GOT refer to the GOT2000 Series User s Manual Hardware Item Specifications Input Color NTSC format PAL format interlaced format format Monochrome EIA format CCIR format interlaced format Number of channels 1 channel Video input Video input signal IVp p 75 Q composite signal section Display size dot e Connector for external connection Applicable wire size 75 Q shielded coaxial cable al shield cable Number of channels 1 channel Sound input Sound input signal 1 Vrms section Connector for external connection Number of channels 1 channel Sound output Sound output signal 1 Vrms Rated load 10k Q section Connector for e
3. unit When installing a CF card into this unit insert it into the card slot of this unit until the CF card eject button pops out Failure to do so may cause a malfunction due to poor contact Before inserting or removing a CF card into from this unit turn the CF card access switch off Failure to do so may corrupt data on the CF card When removing a CF card from the GOT support it by hand as it may pop out Failure to do so may cause the CF card to drop from the unit resulting in a damage or failure DISPOSAL PRECAUTIONS A CAUTION Dispose of this product as industrial waste TRANSPORTATION PRECAUTIONS CAUTION Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the User s Manual for the GOT used as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation When fumigants that contain halogen materials such as fluorine chlorine bromine and iodine are used for disinfecting and protecting wooden packaging from insects they cause malfunction when entering our products Please take necessary precautions to ensure that remaining materials from fumigant do not enter our products or treat packaging with methods other than fumigation heat method Additionally disinfect and protect wood from
4. 60 Thailand Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 Indonesia P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 India Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M I1 D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Australia Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan September 2013
5. ON Exercise care to avoid foreign matter such as chips and wire offcuts entering the unit Not doing so can cause a fire failure or malfunction Make sure to securely connect the cable to the connector of unit Incorrect connection may cause malfunctions STARTUP AND MAINTENANCE PRECAUTIONS ZAAWARNING Before starting cleaning always shut off GOT power externally in all phases Not doing so can cause a unit failure or malfunction Undertightening can cause the GOT to drop short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit Do not disassemble or modify the unit and the CF card Doing so can cause a failure malfunction injury or fire Do not touch the conductive areas and electronic parts of this unit directly Doing so can cause a unit malfunction or failure A CAUTION Always secure the cables connected to the unit e g run them in conduits or clamp them Not doing so can cause unit or cable damage due to dangling moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault Do not hold the cable part when unplugging any cable connected to the unit ae so can cause unit or cable damage or a malfunction due to a cable contact ault Always make sure to touch the grounded metal to discharge the electricity charged in the body etc before touching the unit Failure to do so may cause a failure or malfunctions of the
6. ce Converter Unit GT27 IF 1000 Mounting screw set for GT 16 Multimedia unit 4 screws 40mm 4 stickers Multimedia unit Mounting screw set for Video Interface Converter Unit 2 screws 26mm 2 stickers Cable clamp for sound 1 0 GT27 MMR Z 1 OVERVIEW This user s manual describes the GT27 Multimedia unit hereinafter referred to as the Multimedia unit The Multimedia unit is configured with the GT 16 Multimedia unit and the Video Interface Converter Unit The following functions are available by mounting the Multimedia unit on the GT27 e The GOT displays a video image taken by a video camera or the GOT stores the video image as a video file in a CF card and plays the file When an error occurs a video image taken 120 seconds before and after the error up to 240 seconds can be stored as a video file in a CF card e With the Ethernet connection the GOT sends a video file to the personal computer using the FTP server function SD card in the GOT CF card in the multimedia unit save play Video file Ethernet Video alleges camera KS image GT27 MMR Z XY 1 To store video files in the personal computer the FTP server function of the GOT and the multimedia interaction tool are required 2 Power on the GOT simultaneously with the video camera 3 Depending on the video camera type noise from the
7. control wires or communication cables with the main circuit or power wires or lay them close to each other As a guide separate the lines by a distance of at least 100mm 3 94 inches otherwise malfunctions may occur due to noise INSTALLATION PRECAUTIONS ZAAWARNING Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to from the GOT Not doing so can cause a unit failure or malfunction Before connecting the Bus connection cable to this unit always shut off GOT power and PLC CPU power externally in all phases Not doing so can cause a malfunction A CAUTION Use this unit in the environment that satisfies the general specifications described in the User s Manual for the GOT used Not doing so can cause an electric shock fire malfunction or product damage or deterioration Do not drop the unit or subject it to string shock A unit damage may result When installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to screw or unit damage WIRING PRECAUTIONS ZAAWARNING Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions CAUTI
8. hile the GOT power is on 2 Press the CF card eject button to pop out the CF card and remove the card Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties A For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Germany Mitsubishi Electric Euro
9. insects before packing products Manuals The following shows manuals relevant to this product Detailed Manual Manual number Manual name Model code GOT2000 Series User s Manual Hardware SH 081194ENG Sold separately 1D7MJ5 GOT2000 Series Connection Manual Microcomputer MODBUS Products SH 081200ENG Peripherals For GT Works3 Version 1D7MkK2 Sold separately For detailed manuals refer to the PDF manuals stored in the DVD ROM or CD ROM for the drawing software used Relevant Manuals For relevant manuals refer to the Help or the PDF manuals stored in the DVD ROM or CD ROM for the drawing software used The latest manuals are also available from MITSUBISHI ELECTRIC FA Global Website htto Awww MitsubishiElectric co j 2013 MITSUBISHI ELECTRIC CORPORATION Compliance with the EMC and Low Voltage Directives To configure a system meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi GOT EMC and Low Voltage Directives compliant into other machinery or equipment refer to EMC AND LOW VOLTAGE DIRECTIVES of the General Description included with the GOT used The CE mark indicating compliance with the EMC and Low Voltage Directives is printed on the rating plate of the GOT Packing List After unpacking the box check that the following products are included Product Quantity GT16 Multimedia unit GT16M MMR Z Video Interfa
10. o the GT16 Multimedia unit Position the cable clamp band outside and insert the cable clamp to section A shown in the following figure until it clicks For the band inserting direction refer to the arrow The cable clamp is the RST 1NB manufactured by TAKEUCHI INDUSTRY CO LTD 3 Pull up the two hooks in the extension unit cover two covers of the GOT to remove the cover toward the opposite side of the cover as a fulcrum Cable of the external I O device ean 4 2 Unit Installation The installation procedure for the Multimedia unit is explained using the GT2712 1 Turn off the GOT 2 Pull up the two hooks in the extension unit cover two covers of the GOT to remove the cover toward the opposite side of the hoots of the cover as a fulcrum 3 Connect the Video Interface Converter Unit to the auxiliary extension interface and the extension interface on the GOT After connecting it tighten four mounting screws 26mm with a torque of 0 36Nem to 0 48Nem to fix the unit 4 Fit the GT16 Multimedia unit in the Video Interface Converter Unit case 5 Tighten four mounting screws 40mm of GT16 Multimedia unit with a torque of 0 36Nem to 0 48Nem to fix the unit 6 For mounting any extension unit on GT16 Multimedia unit remove the connector cover and the stickers For mounting no extension unit on the GT16 Multimedia unit cover over four mounting screws with the accessory stickers to the GT16 Multimedia unit o
11. pe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 l 20041 Agrate Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France Tel 33 1 5568 5568 South Africa Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 Hong Kong Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point Hong Kong Tel 852 2887 8870 China Mitsubishi Electric Automation China Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Korea Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Singapore Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 24
12. r the Video Interface Converter Unit to avoid static electricity Keep the connector cover fixed Keep all the stickers fixed Connector cover Accessory sticker Accessory sticker 4 3 Unit Removal For removing the Multimedia unit reverse the procedure of the installation Precautions for connecting sound I O devices Do not connect or disconnect the cables of the sound I O sections during sound input or output Do not connect devices other than sound I O devices to the sound I O sections of the GT16 Multimedia unit Cable clamp 1 Removing cable clamp band The cable clamp band can be removed after the cables are fixed Press the tab of the cable clamp upward using a screwdriver and others and pull out the band 2 Removing cables from the GT16 Multimedia unit The cables of the sound I O devices can be removed from the unit even if the cables are fixed with the cable clamp Remove the cables by pressing the cable clamp from both directions arrow A 5 CF CARD INSTALLATION REMOVAL PROCEDURE 5 1 Installation 1 Open the CF card cover and turn off the CF card access switch of the unit 2 Insert a CF card into the CF card interface with the front side facing up 3 Turn on the CF card access switch 5 2 Removal 1 Open the CF card cover Turn off the CF card access switch and check that the CF card access LED turns off When the CF card access LED is off the CF card can be removed even w
13. xtension unit Mounting screw Screw for fixing the Video Interface Converter Unit Rating plate Connector for video input Connector for connecting a coaxial cable Switch for enabling or disabling access to the CF card CF card access switch ON CF card accessed OFF CF card not accessed LED lamp lit when the CF card is accessed CF card access LED CF card interface Interface for inserting a CF card Terminal for connecting the cable of the sound input Sound input terminal A device Terminal for connecting the cable of the sound output device Video connector connected to the Video Interface Converter Unit Connector for Ethernet communication Connector connected to the Video Interface Converter Unit Sound output terminal Video connector Ethernet interface Interface connector Unit mm inch Description Extension connector Connector for connecting the GT16 Multimedia Unitt Mounting screw Screw for fixing the RGB output unit Rating plate Video connector for connecting the GT16 Multimedia Video connector Unit Auxiliary extension connector Auxiliary extension connector connected to the GOT Interface connector Connector connected to the GOT 4 INSTALLATION AND REMOVAL PRO CEDURE 4 1 Cable Connection 1 Connect the cables of the sound I O devices to the GT16 Multimedia unit 2 Attach the cable clamp t
14. xternal connection CF Card I F Slot Compact flash Slot TYPE1 1 channel section Mode True IDE mode Number of channels 1 channel Ethernet I F Connector for external RJ 45 jack section connection Data transfer method 10BASE T 100BASE TX File format 3GP MP4 Video coding decodin Video file format 9 g MPEG 4 Part 2 SP LV4 Resolution maximum VGA 1 5fps QVGA 30fps frame rate BNC connector 3 5 stereo mini jack straight type 3 5 stereo mini jack straight type 3 3VDC 0 51A 5 0VDC 0 49A accompanied with the GT27 IF1000 Weight 0 41kg accompanied with the GT27 IF 1000 1 Compatible with PAL and CCIR formats only Internal current consumption 3 PART NAMES AND EXTERNAL DIMENSIONS 3 1 GT16 Multimedia Unit 1 2 e 133 5 24 F GT16M MMR Z i a PULL Fa i O G O O a ON ELT 128 5 04 98 3 86 a 2 g O Q 6 l 7 lt Q Sle g 55 OJN y Q o 2 9 8 4 GT27 IF1000 GOT main unit av hey g v S 10 Unit mm inch Description Extension connector Connector for connecting an e