Home
        Product Data Sheet
         Contents
1.    Code Display Options HD HG    M5 LCD display for Aluminum Housing  Available with Housing codes A  B  C  and D only  E D  M6 LCD display for SST Housing  Available with Housing codes J  K  L  and M only          Code Other Options HD HG  Q4 Calibration Data Sheet      Q8 Material traceability certification per EN 10204 3 1 B      QP Calibration certification and tamper evident seal   2  J1 4  Local Zero Adjustment Only  Local zero and span adjustments are standard unless Option   p   Code J1 or J3 is specified    J30 No Local Zero or Span Adjustment  Local zero and span adjustments are standard unless      Option Code J1 or J3 is specified    T1 Transient Protection Terminal Block      c1 Custom Software Configuration  Completed CDS 00806 0100 4001 required with order       c20 0 8 3 2 V dc Output with Digital Signal Based on HART Protocol  Output Code M only        C499   Analog Output Levels Compliant with NAMUR Recommendation NE 43       CN  O Analog Output Levels Compliant with NAMUR Recommendation NE 43  Alarm Configuration Low       P1 Hydrostatic Testing with Certificate       P2 Cleaning for Special Service       P3 Cleaning for  lt 1 PPM Chlorine Fluorine       DF 1 2   14 NPT flange adapters   SST       D8 Ceramic Ball Drain Vents      v5 6  External Ground Screw Assembly        Typical Model Number  3051HG 2 A 2 2 A H 2 1 A B5     1  Materials of Construction comply with recommendations per NACE MR0175 ISO 15156 for sour oil field production environments  Enviro
2.  0 to 800 psia 8 psia            2 5 to 2 5 bar 25 mbar      0 98 to 2 5 bar 25 mbar   0 to 55 2 bar 0 55 bar   4    300 to 300 psi 3 psi    14 2 to 300 psi 3 psi 0 to 4000 psia 40 psia          20 7 to 20 7 bar 0 2 bar    0 98 to 20 7 bar 0 2 bar   0 to 275 8 bar 2 8 bar   5    2000 to 2000 psi 20 psi    14 2 to 2000 psig 20 psi Not Applicable            137 9 to137 9 bar 1 4 bar    0 98 to 137 9 bar 1 4 bar   Code Output cD CG CA  A 4   20 mA with Digital Signal Based on HART Protocol        M      ow Power  1 5 V dc with Digital Signal Based on HART Protocol  See Option C2 for 0 8 3 2 V dc         F FOUNDATION fieldbus Protocol        Ww Profibus     PA d g    Code Materials of Construction CD CG CA  Process Flange Type Flange Material Drain Vent  2 Coplanar SST SST        3 0   Coplanar Alloy C Hastelloy C276        4 Coplanar Monel Monel        5 Coplanar Plated CS SST        70 Coplanar SST Hastelloy C276        8 Coplanar Plated CS Hastelloy C276        0 Alternate Flange   See Options on page Pressure 26        Code  Isolating Diaphragm  04B  forte   07   2    316L SST        30  Hastelloy C276        4 Monel        5 Tantalum  Available on 3051CD and CG  Ranges 2 5 only  Not available on 3051CA           6 Gold plated Monel  Use in combination with O ring Option Code B          7 Gold plated SST        A Glass filled PTFE        B Graphite filled PTFE        Code Fill Fluid cD  oxe  CA  1 Silicone        2 Inert fill  Halocarbon             Pressure 25    Product Dat
3.  20  or D C  Silicone 200  Paint   Polyurethane  Cover O rings   Buna N    Shipping Weights  Refer to    Shipping Weights    on page 38    Rosemount 3051    Pressure 11    Rosemount 3051    Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009    Product Certifications    Approved Manufacturing Locations  Rosemount Inc      Chanhassen  Minnesota USA   Emerson Process Management GmbH  amp  Co      Wessling   Germany   Emerson Process Management Asia Pacific   Private Limited     Singapore   Beijing Rosemount Far East Instrument Co   LTD     Beijing  China    European Directive Information    The EC declaration of conformity for all applicable European  directives for this product can be found on the Rosemount website  at www rosemount com  A hard copy may be obtained by  contacting an Emerson Process Management representative     ATEX Directive  94 9 EC   All 3051 transmitters comply with the ATEX Directive     European Pressure Equipment Directive  PED   97 23 EC   3051CA4  3051CG2  3  4  5  3051CD2  3  4 5   also with P9 option   3051HD2  3  4  5  3051HG2  3  4  5   3051PD2  3  and 3051PG2  3  4  5 Pressure Transmitters      QS Certificate of Assessment   EC No  PED H 100  Module H Conformity Assessment    All other 3051 3001 Pressure Transmitters      Sound Engineering Practice    Transmitter Attachments  Diaphragm Seal   Process  Flange   Manifold      Sound Engineering Practice    Electro Magnetic Compatibility  EMC   2004 108 EC   All 3051 Pressure Transmitter
4.  No span effect    3051H Zero shifts up to  5 inH20  12 43 mbar   which can be calibrated out  No span effect    3051L With liquid level diaphragm in vertical plane  zero shift of up to 1 inH2O  2 49 mbar   With diaphragm in    horizontal plane  zero shift of up to 5 inH2O  12 43 mbar  plus extension length on extended units  All zero  shifts can be calibrated out  No span effect     3051T CA Zero shifts up to 2 5 inH2O  6 22 mbar   which can be calibrated out  No span effect     Vibration Effect    All Models    Measurement effect due to vibrations is negligible except at  resonance frequencies  When at resonance frequencies  vibration  effect is less than  0 1  of URL per g when tested between 15  and 2000 Hz in any axis relative to pipe mounted process  conditions     Power Supply Effect    All Models  Less than  0 005  of calibrated span per volt     RFI Effects  All Models     0 1  of span from 20 to 1000 MHz and for field strength up to 30  Vim     Pressure 6    Transient Protection  Option Code T1   All Models   Meets IEEE C62 41  Category B  6 kV crest  0 5 us   100 kHz   3 kV crest  8 x 20 microseconds   6 kV crest  1 2 x 50 microseconds   Meets IEEE C37 90 1  Surge Withstand Capability  SWC 2 5 kV crest  1 25 MHz wave form  General Specifications   Response Time   lt  1 nanosecond  Peak Surge Current  5000 amps to housing  Peak Transient Voltage  100 V dc  Loop Impedance   lt  25 ohms    Applicable Standards  IEC61000 4 4   IEC61000 4 5       NOTE   Calibrations at 
5.  Proof and intrinsically safe approval  Intrinsically  safe for Class I  Division 1  Groups A  B  C  and D when  connected in accordance with Rosemount drawings  03031 1024  Temperature Code T3C    Explosion Proof for Class I  Division 1  Groups B  C  and D   Dust Ignition Proof for Class II and Class III  Division 1   Groups E  F  and G  Suitable for Class    Division 2 Groups  A  B  C  and D hazardous locations  Enclosure type 4X   factory sealed   For input parameters see control drawing 03031 1024     Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009    European Certifications    1    N1    E8    ATEX Intrinsic Safety and Dust   Certification No   BAS 97ATEX1089X    9 II 1 GD  EEx ia IIC T4   60  lt  T   lt   70   C    Dust Rating  T80   C   20  lt  T4  lt  40   C  IP66  ce 1180    TABLE 5  Input Parameters  U    30V   l    200 mA   Pj   0 9W   Cj   0 012 uF    Special Conditions for Safe Use  X     When the optional transient protection terminal block is  installed  the apparatus is not capable of withstanding the  500V insulation test required by Clause 6 4 12 of  EN50020 1994  This must be taken into account when  installing the apparatus     ATEX Type n and Dust   Certification No   BAS OOATEX3105X    9 II 3 GD  U    55 Vdc max   EEx nL T5   40 C  lt  Tamb  lt  70   C    Dust rating  T80   C   20  lt  T4  lt  40   C  IP66   cE    Special Conditions for Safe Use  X     When the optional transient protection terminal block is  installed  the apparatus is 
6.  accuracy    Installed five year stability of 0 12596      Calibrated spans from 0 3 to 10000 psi   10 3 mbar to 689 bar       Multiple process connections available    316L SST and Hastelloy C276 process isolators    Rosemount 3051L Liquid Level  See ordering information on   page Pressure 31    e Performance up to 0 075  accuracy    e Welded fill fluid system provides  best in class system reliability      Flush and extended diaphragms      Multiple fill fluids and wetted materials  available                         Pressure 3    Product Data Sheet  00813 0100 4001  Rev HA    Rosemount 3051 Catalog 2008   2009    Specifications    PERFORMANCE SPECIFICATIONS    Total Performance is based on combined errors of reference accuracy  ambient temperature effect  and static pressure effect   This product data sheet covers both HART and fieldbus protocols unless specified     Conformance To Specification   30  Sigma    Technology leadership  advanced manufacturing techniques and statistical process control ensure specification conformance to at least  30     Reference Accuracy    Models  3051CD  3051CG  Range 0  CD   0 10  of span  For spans less than 2 1  accuracy     0 05  of URL    Range 1  0 10  of span  For spans less than 15 1  accuracy      fo  025   0  oos R       Standard High Accuracy Option      of Span    Ranges 2 5  0 065  of span  For spans less than 10 1  accuracy      Ranges 2 4  High Accuracy Option  P8   0 04  of span    fo  015   0 005  URL  Spun    of Span For sp
7.  connection  and extension   QZ Remote Seal System Performance Calculation Report  QP Calibration certification and tamper evident seal  J18  4  Local Zero Adjustment Only  J3 3X4  No Local Zero or Span Adjustment  T1 Transient Protection Terminal Block  c1 Custom Software Configuration  Completed CDS 00806 0100 4001 required with order   c2  0 8   3 2 V dc Output with Digital Signal Based on HART Protocol  Available with Output code M only     c4G9  Analog Output Levels Compliant with NAMUR Recommendation NE 43  CNEX    Analog Output Levels Compliant with NAMUR Recommendation NE 43  Alarm Configuration Low    D8 Ceramic Ball Drain Vents  v5 6 External Ground Screw Assembly   e  1 Lower Housing Flushing Connections Options  Ring Material Number Size 2in  3in  4in   F1 SST 1 1 4        F2 SST 2 1 4        F30  Hastelloy C276 1 1 4        F40  Hastelloy C276 2 1 4 o   7  F7 SST 1 1 2        F8 SST 2 1 2        F9 Hastelloy C276 1 1 2     E  FO Hastelloy C276 2 1 2 5 9 z    Typical Model Number  3051L 2 A AO D 21 A A F1     1     Assemble to    items are specified separately and require a completed model number     2  Not available with low power Option Code M    3  Not available with fieldbus  output code F  or profibus protocols  output code W      4  Local zero and span adjustments are standard unless Option Code J1 or J3 is specified     5  NAMUR Compliant operation is pre set at the factory and cannot be changed to standard operation in the field    6  The V5 option is not 
8.  real world     transmitter performance  Using superior sensor  technology and engineered for optimal performance   the 3051 delivers unprecedented  0 04  reference  accuracy  resulting in total operating performance of   0 15   Superior total performance equates to  reduced variability and improved plant safety     Installed five year stability of 0 125   Transmitter stability is a critical measure of  transmitter performance over time  Through  aggressive simulation testing beyond standard IEC  770 testing  the 3051 has proven its ability to  maintain performance over a five year period under  the most demanding process conditions  Superior  transmitter stability reduces calibration frequency to  save operation and maintenance costs     Unmatched dynamic performance   In dynamic applications  speed of measurement is as  important as repeatability  The 3051 responds up to  eight times faster than the typical pressure  transmitter to detect and control variations quickly  and efficiently  Superior dynamic response yields  more accurate measurements to reduce variability  and increase profitability     Coplanar platform enables complete point  solutions   The versatile Coplanar platform design enables the  best process connection for pressure  flow and level  applications  Right out of the box  the solution arrives  factory calibrated  pressure tested  and ready to  install  Only the 3051 has a flexible design to reduce  engineering and inventory costs     Advanced PlantWeb Fu
9. 0    TABLE 8  Input Parameters  U    17 5 V        380 mA   Pj   5 32 W   C   lt 5 uF   Lj   x 10 pH    Special Conditions for Safe Use  X     The device is not capable of withstanding the 500V  insulation test required by Clause 6 4 12 of EN50020 1994   This must be taken into account when installing the  apparatus     ATEX Type n and Dust   Certification No   BAS 98ATEX3356X     Il 3 GD  U    40 Vdc max   EEx nL IIC T5  T4      40  C to 70   C    Dust rating  T80   C  Tamb   720 to 40   C  IP66    Special Conditions for Safe Use  X     The device is not capable of withstanding the 500V  insulation test required by Clause 6 4 12 of EN50020 1994   This must be taken into account when installing the  apparatus     ATEX Flame Proof and Dust   Certification No   KEMA 00ATEX2013X      II 1 2 GD  EEx d IIC T6  Tamb      50 to 65   C    Dust rating T90   C  IP66   ce 1180   Vmax   55 V dc    Special Conditions for Safe Use  X     This device contains a thin wall diaphragm  Installation   maintenance  and use shall take into account the  environmental conditions to which the diaphragm will be  subjected  The manufacturer s instructions for installation  and maintenance shall be followed in detail to assure safety  during its expected lifetime     Pressure 15    Rosemount 3051    Japanese Certifications    E4    TIIS Flame Proof    Ex d IIC T6   Certificate Description   C15852 3051C D 1 FOUNDATION Fieldbus      no display   C15853 3051C D 1 FOUNDATION Fieldbus      with display   C1
10. 031 1026    TABLE 6  Input Parameters    U    30V   l    200 mA   lj   160 mA  output code A with T1   Pj   0 9W   Cj   0 01 uF   Cj   0 042 HF  output code M    L   10 uH    L    1 05 mH  output code A with T1   Lj   0 75 mH  output code M with T1     Special Conditions for Safe Use  X     The apparatus may only be used with a passive current  limited power source Intrinsic Safety application  The power  Source must be such that Po x  Uo   lo    4  Modules using  transient protection in the terminal assembly  T1 transient  protection models  the apparatus enclosure is to be  electrically bonded to the protective earth  The conductor  used for the connection shall be equivalent to a copper  conductor of 4 mm  minimum cross sectional area     Pressure 13    Rosemount 3051    E7 SAA Explosion Proof  Flame Proof   Certification No   AUS Ex 03 1347X  Ex d IIC T6  Tamp   40   C   DIP A21 T6  Tamb   40   C   IP66    Special Conditions for Safe Use  X     It is a condition of safe use for transmitter enclosures having  cable entry thread other than metric conduit thread that the  equipment be utilized with an appropriate certified thread  adaptor     N7 SAA Type n  Non sparking   Certification No   AUS Ex 1249X  Ex n IIC T4  Tamb   70   C   IP66    Special Conditions for Safe Use  X     Where the equipment is installed such that there is an  unused conduit entry  it must be sealed with a suitable  blanking plug to maintain the IP66 degree of protection  Any  blanking plug used with 
11. 1  Not available on low power or previous versions     LCD display  M5 Digital Display  5 Digit  2 Line LCD    Direct reading of digital data for  higher accuracy    Displays user defined flow  level  volume  or pressure units    Displays diagnostic messages for local troubleshooting    90 degree rotation capability for easy viewing  M6 Digital Display with 316 Stainless Steel Cover      For use with stainless steel housing option  housing codes J   K  and L     Local Span and Zero Adjustment      Transmitters ship with local span and zero adjustments standard  unless otherwise specified       Non interactive external zero and span adjustments ease  calibration      Magnetic switches replace standard potentiometer  adjustments to optimize performance    J1 Local Zero Adjustment Only     J3 No Local Zero or Span Adjustment      Transient Protection   T1 Integral Transient Protection Terminal Block  Integral transient protection terminal block  Meets IEEE Standard 587  Category B   1 KV crest  10 x 1 000 microseconds    3 kV crest  8 X 20 microseconds    6 kV crest  1 2 x 50 microseconds   Meets IEEE Standard 472    Surge Withstand Capability   SWC 2 5 kV crest  1 MHz wave form  Applicable standards  IEC 801 4  801 5    Bolts for Flanges and Adapters      Options permit bolts for flanges and adapters to be obtained in  various materials      Standard material is plated carbon steel per ASTM A449  Type 1  L4  Austenitic 316 Stainless Steel Bolts  L5 ASTM A 193  Grade B7M Bolts  
12. 1 0 56246 56 2456 2 81228 281 228 140 614 701 82       Pa 2068 43 206843 10342 1 1034212 55158 1 5515811 275791 27579054 13789500 68947600  kPa 2 06843 206 843 10 3421 1034 21 55 1581 5515 81 275 791 27579 05 13789 5 68947 6  torr 15 5145 1551 45 77 5726 7757 26 413 721 413721 2068 6 206859 7 103430 517151  atm 0 02041 2 04138 0 10207 10 2069 0 54437 54 4368 2 72184 272 1841 136 092 680 46    When using a HART communicator   5  adjustment is allowed on the sensor limit to allow for unit conversions     3051C Absolute Pressure Transmitter Range Limits       Range 1 Span Range 2 Span Range 3 Span Range 4 Span  min max min max min max min max  inH2O 8 30397 831 889 41 5198 4151 98 221 439 22143 9 1107 2 110720  inHg 0 61081 61 0807 3 05403 305 403 16 2882 1628 82 81 441 8144 098  ftH2O 0 69199 69 3241 3 45998 345 998 18 4533 1845 33 92 2663 9226 63  mmH2O 211 10 21130 6 35308 635 308 5634 66 563466 28146 1 2814613  mmHg 15 5145 1551 45 1055 47 105547 413 72 41372 2068 6 206860 0  psi 0 3 30 1 5 150 8 800 40 4000  bar 0 02068 2 06843 0 10342 10 342 0 55158 55 1581 2 75791 275 7905  mbar 20 6843 2068 43 103 421 10342 1 551 581 55158 1 2757 91 275790 5  g cm  21 0921 2109 21 105 27 105 27 561 459 56145 9 2807 31 280730 6  kg cm  0 02109 2 10921 0 10546 10 546 0 56246 56 2456 2 81228 281 228  Pa 2068 43 206843 10342 1 1034210 55158  1 5515811 275791 27579054  kPa 2 06843 206 843 10 3421 1034 21 55 1581 5515 81 275 791 27579 05  torr 15 5145 1551 45 77 5726 7757 26 413 721 413721 206
13. 17 to 205   C    P Propylene Glycol and Water 0 to 200   F   17 to 93   C     Low Pressure Side       Code Configuration Flange Adapter Diaphragm Material Sensor Fill Fluid       Gage 316L SST Silicone  21 Differential SST 316L SST Silicone  22 Differential SST Hastelloy C276 Silicone  2A Differential SST 316L SST Inert  Halocarbon   2B Differential SST Hastelloy C276 Inert  Halocarbon   31 Remote Seal SST 316L SST Silicone  Requires Option Code S1   Code O ring Material  A Glass filled PTFE    Pressure 32    Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009 Rosemount 3051    TABLE 13  3051L Flange Mounted Liquid Level Transmitter     eof  5 Housing Material Conduit Entry Size  A Polyurethane covered Aluminum 72 14 NPT  B Polyurethane covered Aluminum M20 x 1 5  CM20   C Polyurethane covered Aluminum PG 13 5  D Polyurethane covered Aluminum G   J SST 72 14 NPT  K SST M20 x 1 5  CM20   L SST PG 13 5    M SST GR   e  1 PlantWeb Functionality  Optional         A01 Advanced Control Function Block Suite    D01 FOUNDATION fieldbus Diagnostics Suite   e  1 Diaphragm Seal Assemblies  Optional        S1 One Diaphragm Seal  requires low pressure side Option Code 31 capillary connection type     Code Hazardous Locations Certification Options       E5 FM Explosion proof Approval    15 FM Non incendive and Intrinsic Safety Approval  IE FM FISCO Intrinsically Safe  for FOUNDATION fieldbus protocol only  K5 FM Explosion proof and Intrinsic Safety Approval  14  ATEX Intrinsic 
14. 1T  Range and Sensor Limits Range and Sensor Limits  Minimum Upper Lower Minimum Upper Lower Lower    Span  URL    8 18  Span  URL   E15   LRL   Gage    1 0 3 psia 30 psia 0 psia 1 0 3 psi 30 psi 0 psia  14 7 psig   20 6 mbar   2 07 bar   0 bar   20 6 mbar   2 07 bar   0 bar    1 01 bar    2 1 5 psia 150 psia 0 psia 2 1 5 psi 150 psi 0 psia  14 7 psig   0 103 bar   10 3 bar   0 bar   0 103 bar   10 3 bar   0 bar   71 01 bar    3 8 psia 800 psia 0 psia 3 8 psi 800 psi 0 psia  14 7 psig   0 55 bar   55 2 bar   0 bar   0 55 bar   55 2 bar   0 bar   71 01 bar    4 40 psia 4000 psia 0 psia 4 40 psi 4000 psi 0 psia    14 7 psig   2 76 bar   275 8 bar   0 bar   2 76 bar   275 8 bar   0 bar   71 01 bar    5 2000 psi 10000 psi 0 psia  14 7 psig   137 9 bar   689 4 bar   0 bar   71 01 bar      1  Assumes atmospheric pressure of 14 7 psig     Pressure 7    Rosemount 3051    Zero and Span Adjustment Requirements   HART and Low Power     Zero and span values can be set anywhere within the range limits  stated in Table 1 and Table 2     Span must be greater than or equal to the minimum span stated in  Table 1 and Table 2     Service  Liquid  gas  and vapor applications    4   20 mA  Output Code A   Output    Two wire 4   20 mA  user selectable for linear or square root  output  Digital process variable superimposed on 4   20 mA    signal  available to any host that conforms to the HART protocol     Power Supply    External power supply required  Standard transmitter  4   20 mA   operates o
15. 4 140614  kg cm  0 00635 0 635 0 0254 2 54 0 21092 21 0921 1 40614 140 614   Pa 622 723 62160 6 2490 89 249089 20684 3 2068430 137895 13789500   kPa 0 62272 62 2723 2 49089 249 089 20 6843 2068 43 137 895 13789 5  torr 4 67082 467 082 18 6833 1868 33 155 145 15514 5 1034 3 103430  atm 0 00615 0 61460 0 02458 2 458 0 20414 20 4138 1 36092 136 092    When using a HART communicator   5  adjustment is allowed on the sensor limit to allow for unit conversions     Pressure 39    Product Data Sheet  00813 0100 4001  Rev HA    Rosemount 3051 Catalog 2008   2009    3051T Gage and Absolute Pressure Transmitter Range Limits    Range 1 Span Range 2 Span Range 3 Span Range 4 Span Range 5 Span    min max min max min max min max min max   inH O 8 30397 831 889 41 5198 4159 45 221 439 22143 9 1107 2 110720 55360 276799  inHg 0 61081 61 0807 3 05403 305 403 16 2882 1628 82 81 441 8144 098     4072 04 20360 2  ftHzO 0 69199 69 3241 3 45998 345 998 18 4533 1845 33 92 2663 9226 63 4613 31 23066 6  mmH 0 211 10 21130 1054 60 105460 3 5634 66 563466 28146 1 2814613 1407301 7036507  mmHg 15 5145 1551 45 77 5723 7757 23 413 72 41372 2068 6 206860 0 103430 517151   psi 0 3 30 1 5 150 8 800 40 4000 2000 10000   bar 0 02068 3 06843 0 10342 10 3421 0 55158 55 1581 2 75791 275 7905 137 895 689 476  mbar 20 6843 2068 43 103 421 10342 11 551 581 55158 1 2757 91 275790 5 137895 689476  g cm  21 0921 2109 21 105 461 10546 1 561 459 56145 9 2807 31 280730 6 140614 703067  kg cm  0 02109 2 10921 0 10546 10 546
16. 4001  Rev HA  Rosemount 3051 Catalog 2008   2009    TABLE 10  3051L Dimensional Specifications  Except where indicated  dimensions are in inches  millimeters         Pipe Flange Bolt Circle Outside No  of Bolt Hole Extension O D  Gasket  Size Thickness A DiameterB DiameterC Bolts Diameter Diameter   D Surface E  ASME B16 5  ANSI  150 2  51  0 69  18  4 75  121  6 0  152  4 0 75  19  NA 3 6  92   3  76  0 88  22  6 0  152  7 5  191  4 0 75  19  2 58  66  5 0  127   4  102  0 88  22  7 5  191  9 0  229  8 0 75  19  3 5  89  6 2  158   ASME B16 5  ANSI  300 2  51  0 82  21  5 0  127  6 5  165  8 0 75  19  NA 3 6  92   3  76  1 06  27  6 62  168  8 25  210  8 0 88  22  2 58  66  5 0  127   4  102  1 19  30  7 88  200  10 0  254  8 0 88  22  3 5  89  6 2  158   ASME B16 5  ANSI  600 2  51  1 00  25  5 0  127  6 5  165  8 0 75  19  NA 3 6  92   3  76  1 25  32  6 62  168  8 25  210  8 0 88  22  2 58  66  5 0  127   DIN 2501 PN 10   40 DN 50 20 mm 125 mm 165 mm 4 18 mm NA 4 0  102   DIN 2501 PN 25 40 DN 80 24 mm 160 mm 200 mm 8 18 mm 65 mm 5 4  138   DN 100 24 mm 190 mm 235 mm 8 22 mm 89 mm 6 2  158   DIN 2501 PN 10 16 DN 100 20 mm 180 mm 220 mm 8 18 mm 89 mm 6 2  158   Pipe Process Lower Housing G  Class Size Side F 1 4 NPT 1 2 NPT H  ASME B16 5  ANSI  150 2  51  2 12  54  0 97  25  1 31  33  5 65  143   3  76  3 6  91  0 97  25  1 31  33  5 65  143   4  102  3 6  91  0 97  25  1 31  33  5 65  143   ASME B16 5  ANSI  300 2  51  2 12  54  0 97  25  1 31  33  5 65  143   3  76  3 6  
17. 5858 3051T G 1 FOUNDATION Fieldbus  SST  Silicon      no display   C15859 3051T G 1 FOUNDATION Fieldbus  Hastelloy  C276  Silicon     no display   C15860 3051T G 1 FOUNDATION Fieldbus  SST  Silicon      with display   C15861 3051T G 1 FOUNDATION Fieldbus  Hastelloy    C276  Silicon     with display    Australian Certifications    I7    SAA Intrinsic Safety   Certification No   AUS Ex 1249X   Ex ia IIC T4  Tap   60   C    IP66   When connected per Rosemount drawing 03031 1026     TABLE 9  Input Parameters    U    30 V  li   300 mA  Pj213W  C  20 pF  L  2 0 uH    Special Conditions for Safe Use  X     The apparatus may only be used with a passive current  limited power source Intrinsic Safety application  The power  Source must be such that Po x  Uo   lo    4  Modules using  transient protection in the terminal assembly  T1 transient  protection models  the apparatus enclosure is to be  electrically bonded to the protective earth  The conductor  used for the connection shall be equivalent to a copper  conductor of 4 mm2 minimum cross sectional area     Pressure 16    Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009    E7  SAA Explosion Proof  Flame Proof   Certification No   AUS Ex 1347X  Ex d IIC T6  Tamb   40   C   DIP A21 T6  Tag   40   C   IP66    Special Conditions for Safe Use  X     It is a condition of safe use for transmitter enclosures having  cable entry thread other than metric conduit thread that the  equipment be utilized with an appropriate certif
18. 6127 36 127 3 300 20 2000  bar 0 00125 0 06227 0 00623 0 62272 0 02491 2 491 0 20684 20 6843 1 37895 137 895  mbar 1 2454 62 2723 6 22723 622 723 24 9089 2490 89 206 843 20684 3 1378 95 137895  g cm  1 26775 63 3875 6 33875 633 875 25 355 2535 45 210 547 21054 7 1406 14 140614  kg cm  0 00127 0 0635 0 00635 0 635 0 0254 2 54 0 21092 21 0921 1 40614 140 614  Pa 124 545 6227 23 622 723 62160 6 2490 89 249089 20684 3 2068430 137895 13789500  kPa 0 12545 6 2272 0 62272 62 2723 2 49089 249 089 20 6843 2068 43 137 895 13789 5  torr 0 93416 46 7082 4 67082 467 082 18 6833 1868 33 155 145 15514 5 1034 3 103430  atm 0 00123 0 06146 0 00615 0 61460 0 02458 2 458 0 20414 20 4138 1 36092 136 092    When using a HART communicator   5  adjustment is allowed on the sensor limit to allow for unit conversions     3051L 3051H Pressure Transmitter Range Limits       Range 2 Span Range 3 Span Range 4 Span Range 5 Span   min max min max min max min max   inH2O 2 5 250 10 1000 83 040 8304 553 60 55360  inHg 0 18389 18 389 0 73559 73 559 6 1081 610 81 40 720 4072 04  ftH2O 0 20833 20 8333 0 83333 83 3333 6 9198 691 997 46 13 4613 31  mmH 0 63 553 6355 254 25421 2110 95 211095 14073 1407301  mmHg 4 67082 467 082 18 6833 1868 33 155 145 15514 5 1034 3 103430   psi 0 0902 9 03183 0 36127 36 127 3 300 20 2000  bar 0 00623 0 62272 0 02491 2 491 0 20684 20 6843 1 37895 137 895  mbar 6 22723 622 723 24 9089 2490 89 206 843 20684 3 1378 95 137895  g cm  6 33875 633 875 25 355 2535 45 210 547 21054 7 1406 1
19. 68   F  20   C  per ASME Z210 1  ANSI        Product Data Sheet  00813 0100 4001  Rev HA    Catalog 2008   2009 Rosemount 3051    FUNCTIONAL SPECIFICATIONS    Range and Sensor Limits    TABLE 1  3051CD  3051CG  3051L  and 3051H Range and Sensor Limits  Range and Sensor Limits    Minimum Span       Lower  LRL   3051CD    Upper 3051C 3051C  3051L 3051L 3051H  CG  L  H  URL  Differential Gage Differential Gage Differential  0  0 1inH2O 3 0 inH2O    3 0 inH2O NA NA NA NA NA   0 25 mbar   7 47 mbar    7 47 mbar   1 0 5 inH2O 25 inH2O    25 inH2O    25 inH2O NA NA NA NA   1 2 mbar   62 3 mbar   762 1 mbar   762 1 mbar   2  2 5inH2O 250 inH2O    250 inH2O    250 inH2O    250 inH2O    250 inH2O    250 inH2O    250 inH2O   6 2 mbar   0 62 bar   70 62 bar   70 62 bar    0 62 bar    0 62 bar    0 62 bar   70 62 bar   3 10 inH2O 1000 inH2O    1000 inH2O 0 5 psia    1000 inH2O 0 5 psia    1000 inH2O 0 5 psia   24 9 mbar   2 49 bar      2 49 bar   34 5 mbar abs      2 49 bar   34 5 mbar abs     2 49 bar   34 5 mbar abs   4 3 psi 300 psi    300 psi 0 5 psia    300 psi 0 5 psia    300 psi 0 5 psia   0 20 bar   20 6 bar    20 6 bar   34 5 mbar abs    20 6 bar   34 5 mbarabs     20 6bar   34 5 mbar abs   5 20 psi 2000 psi     2000 psi 0 5 psia NA NA     2000 psi 0 5 psia   1 38 bar   137 9 bar    137 9 bar   34 5 mbar abs    137 9 bar   34 5 mbar abs      1  Range 0 only available with 3051CD  Range 1 only available with 3051CD or 3051CG     TABLE 2  Range and Sensor Limits          3051CA 305
20. 8 6 206859 7  atm 0 02041 2 04138 0 10207 10 207 0 54437 54 4368 2 72184 272 1841    When using a HART communicator   5  adjustment is allowed on the sensor limit to allow for unit conversions     Pressure 40    Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009 Rosemount 3051    Pressure 41    Product Data Sheet  00813 0100 4001  Rev HA    Rosemount 3051 Catalog 2008   2009    Standard Terms and Conditions of Sale can be found at www rosemount com terms_of_sale   The Emerson logo is a trade mark and service mark of Emerson Electric Co    Rosemount  Annubar  ProPlate  and the Rosemount logotype are registered trademarks of Rosemount Inc   PlantWeb is a registered trademark of one of the Emerson Process Management group of companies   Instrument Toolkit is a registered trademark of Emerson Process Management    Complete Point Solutions  Coplanar and Multivariable are trademarks of Rosemount Inc    HART is a registered trademark of the HART Communications Foundation    Hastelloy is a registered trademark of Haynes international  Inc     Monel is a registered trademark of the Special Metals Corporation group of Companies    Syltherm 800  Dow Corning  and D C  are registered trademarks of Dow Corning Co    Neobee M 20 is a registered trademark of Stephan Chemical Co    The 3 A symbol is a registered trademark of the 3 A Sanitary Standards Symbol Council    FOUNDATION fieldbus is a registered trademark of the Fieldbus Foundation    Fluorinert is a registered trademar
21. 91  0 97  25  1 31  33  5 65  143   4  102  3 6  91  0 97  25  1 31  33  5 65  143   ASME B16 5  ANSI  600 2  51  2 12  54  0 97  25  1 31  33  7 65  194   3  76  3 6  91  0 97  25  1 31  33  7 65  194   DIN 2501 PN 10 40 DN 50 2 4  61  0 97  25  1 31 33  5 65  143   DIN 2501 PN 25 40 DN 80 3 6  91  0 97  25  1 31 33  5 65  143   DN 100 3 6  91  0 97  25  1 31 33  5 65  143   DIN 2501 PN 10 16 DN 100 3 6  91  0 97  25  1 31 33  5 65  143      1  Tolerances are 0 040  1 02      0 020  0 51      Pressure 24    Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009 Rosemount 3051    Ordering Information    TABLE 11  3051C Differential  Gage  and Absolute Pressure Transmitters       Not Applicable       Applicable    Model Transmitter Type  Select One  CD CG CA  3051CD Differential Pressure Transmitter            3051CG Gage Pressure Transmitter            3051CA Absolute Pressure Transmitter             Code Pressure Ranges  Range Min  Span  cD CG CA   3051CD 3051CG 3051CA  0     3to3inH4O 0 1 inH2O Not Applicable Not Applicable            7 5 to 7 5 mbar 0 25 mbar   1    25 to 25 inH2O 0 5 inH2O    25 to 25 inH20O 0 5 inH2O 0 to 30 psia 0 3 psia         762 2 to 62 2 mbar 1 2 mbar    62 1 to 62 2 mbar 1 2 mbar   0 to 2 1 bar 20 7 mbar   2    250 to 250 inH20 2 5 inH2O    250 to 250 inH20 2 5 inH2O 0 to 150 psia 1 5 psia          623 to 623 mbar 6 2 mbar    621 to 623 mbar 6 2 mbar   0 to 10 3 bar 0 1 bar   3    1000 to 1000 inH 0 10 inH 0    393 to 1000 inH 0 10in H20
22. C4 3 in  DN 80 Hastelloy C276 4 in  100 mm  C6 3 in  DN 80 Hastelloy C276 6 in  150 mm  DO 4 in  DN 100 Hastelloy C276 Flush Mount  D2 4 in  DN 100 Hastelloy C276 2 in  50 mm  D4 4 in  DN 100 Hastelloy C276 4 in  100 mm  D6 4 in  DN 100 Hastelloy C276 6 in  150 mm  EO 3 in  DN 80 Tantalum Flush Mount Only  FO 4 in  DN 100 Tantalum Flush Mount Only    Pressure 31    Product Data Sheet  00813 0100 4001  Rev HA  Rosemount 3051 Catalog 2008   2009    TABLE 13  3051L Flange Mounted Liquid Level Transmitter  Code Mounting Flange    Size ASME B 16 5  ANSI  or DIN Flange Rating Material   M 2 in  Class 150 CS   A 3 in  Class 150 CS   B 4 in  Class 150 CS   N 2 in  Class 300 CS   C 3 in  Class 300 CS   D 4 in  Class 300 CS   P 2 in  Class 600 CS   E 3 in  Class 600 CS   X 2 in  Class 150 SST   F 3 in  Class 150 SST   G 4 in  Class 150 SST   Y 2 in  Class 300 SST   H 3 in  Class 300 SST   J 4 in  Class 300 SST   Z 2 in  Class 600 SST   L 3 in  Class 600 SST   Q DN 50 PN 10 40 CS   R DN 80 PN 40 CS   S DN 100 PN 40 CS   V DN 100 PN 10 16 CS   K DN 50 PN 10 40 SST   T DN 80 PN 40 SST   U DN 100 PN 40 SST   Ww DN 100 PN 10 16 SST   e  1 Process Fill High Pressure Side Temperature Limits   A Syltherm XLT    100 to 300   F   73 to 135   C    C D  C  Silicone 704 60 to 400   F  15 to 205   C    D D  C  Silicone 200    40 to 400   F     40 to 205   C    H Inert  Halocarbon     50 to 350   F   45 to 177   C    G Glycerine and Water 0 to 200   F   17 to 93   C    N Neobee M 20 0 to 400   F     
23. Code Process Connection HD HG   Process Flange Material Drain Vent  2 SST SST      7 SST Hastelloy C276       Code Process Isolating Diaphragm HD HG  2 316L SST      3  Hastelloy C276      5 Tantalum       Code O ring Material HD HG  A Glass Filled PTFE       Code Process Fill Fluid HD HG  D D C  200 Silicone      H Inert      N Neobee M 20       Code Sensor Module Isolator Material HD HG  2 SST       Code Sensor Module Fill Fluid HD HG  1 Silicone      2 Inert  Halocarbon        Code Housing Material Conduit Entry Size HD HG  A Polyurethane covered Aluminum 72 14 NPT      B Polyurethane covered Aluminum M20 x 1 5  CM20       C Polyurethane covered Aluminum PG 13 5      D Polyurethane covered Aluminum Gh      J SST 72 14 NPT      K SST M20 x 1 5  CM20       L SST PG 13 5      M SST G         Code PlantWeb Functionality  Optional   A01 Advanced Control Function Block Suite       D01 FOUNDATION fieldbus Diagnostics Suite  Code Integral Mount Primary Elements  Optional  HD HG  S4 Factory Assembly to Rosemount Primary Element  Rosemount Annubar or Rosemount 1195 Integral Orifice          With the primary element installed  the maximum operating pressure will equal the lesser of either the  transmitter or the primary element  Option is available for factory assembly to range 1   4 transmitters only     Pressure 35    Product Data Sheet  00813 0100 4001  Rev HA  Rosemount 3051 Catalog 2008   2009    TABLE 14  3051H Pressure Transmitter for High Temperature Processes       Not Appli
24. L6  Monel Bolts     2  Not applicable to fieldbus     Pressure 37    Product Data Sheet  00813 0100 4001  Rev HA    Rosemount 3051 Catalog 2008   2009  Rosemount 3051C Coplanar Flange and 3051T Bracket Shipping Weights  Option mm   TABLE 15  Transmitter Weights without Options  B4 Bracket Tor 2 in  Pipe or Panel Mounting Transmitter Add Weight In Ib  kg     For use with the standard Coplanar  flange configuration 3051C 6 0  2 7     Bracket for mounting of transmitter on 2 in  pipe or panel 3051L Table 16 on page 38    Stainless steel construction with stainless steel bolts 3051H 13 6  6 2   3051T 3 0  1 4     Rosemount 3051H Bracket Options  B5 Bracket for 2 in  Pipe or Panel Mounting      For use with the 3051H Pressure Transmitter for high process TABLE  107200 Weights without Options  temperatures Flush 2 in  Ext  4 in  Ext  6 in  Ext   Flange Ib   kg  Ib  kg  Ib  kg  Ib  kg          Carbon steel construction with carbon       steel bolts 2 in   150 12 5  5 7               B6 B5 Bracket with SST Bolts 9 in  150 17 5  7 9  19 5  8 8  20 5  9 3  21 5  9 7     Same bracket as the B5 option with Series 300 stainless steel 4 in   150 23 5  10 7  26 5  12 0  28 5  12 9  30 5  13 8    bolts  2 in   300 17 5  7 9               3 in  300 22 5  10 2  24 5  11 1  25 5  11 6  26 5  12 0   Traditional Flange Bracket Options 4 in  300 32 5  14 7  35 5  16 1  37 5  17 0  39 5  17 9    B1 Bracket for 2 in  Pipe Mounting 2 in   600 15 3  6 9             For use with the traditional flange 
25. Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009    Rosemount 3051    Rosemount 3051 Pressure Transmitter    THE PROVEN INDUSTRY LEADER IN  PRESSURE MEASUREMENT      Best in Class performance with 0 04  High  Accuracy option      Industry first installed five year stability    Unmatched Dynamic Performance      Coplanar    platform enables integrated  pressure  flow  and level solutions    Advanced PlantWeb   Functionality to  increase plant productivity                   Contents       CE                FOUNDATION    Product Offering  s  eces cesse bee a E ee a page Pressure 3    Specifications  s o ae OG RERO E ER A ea e anir ls E e i page Pressure 4    Product Certifications         aasa auaa aaaea  HART Protocol sesasi bd nate vee EE EAR ERE Reden EEA  Fieldbus Protocol  ocs sciare rce eee eae   Dimensional Drawings  s  csreisnsa dtaa didaba ee eee    Ordering Information      n   anaana aaa    ROSEMOUNT    page Pressure 12  page Pressure 12  page Pressure 15  page Pressure 17    page Pressure 25    EMERSON        www rosemount com    Process Management    Rosemount 3051    Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009    Setting the Standard for Pressure Measurement    Industry s best total performance  a flexible Coplanar platform  and installed five year stability  has made the    Rosemount 3051 the standard in pressure measurement     Industry s best in class total performance   of  0 15    Total performance is the true measure of   
26. S Process Connection   RC 74 Flange with RC 72 Flange Adapter         P8 0 0496 accuracy to 5 1 turndown  Range 2 4         P9 4500 psig Static Pressure Limit  3051CD Ranges 2 5 only             V5 9  External Ground Screw Assembly          Typical Model Number  3051CD 2 A 2 2 A 1 A B4     1  3051CG lower range limit varies with atmospheric pressure      2  3051CDO0 is available only with Output Code A  Process Flange Code 0  Alternate Flange H2  H7  HJ  or HK   Isolating Diaphragm Code 2  O ring Code  A  and Bolting Option L4      3  Not available with hazardous locations certification Options Codes I1  N1  E4  K6 and K8      4  Materials of Construction comply with recommendations per NACE MR0175 ISO 15156 for sour oil field production environments  Environmental limits  apply to certain materials  Consult latest standard for details  Selected materials also conform to NACE MRO0103 for sour refining environments      5     Assemble to    items are specified separately and require a completed model number     6  Not available with Low Power code M     7  Not available with Fieldbus  output code F  or Profibus  output code W      8  Local zero and span adjustments are standard unless Option Code J1 or J3 is specified    9  NAMUR Compliant operation is pre set at the factory and cannot be changed to standard operation in the field      10  The V5 option is not needed with the T1 option  external ground screw assembly is included with the T1 option     Pressure 28    Product Da
27. Safety and Dust Certification  N10  ATEX Type N and Dust Certification  E8 ATEX Flame proof and Dust Certification  E40 TIIS Flame proof Certification  C6 CSA Explosion proof and Intrinsic Safety Approval  Ke  CSA and ATEX Explosion proof and Intrinsic Safety Approval  combination of C6 and K8   KB FM and CSA Explosion proof and Intrinsic Safety Approvals  combination of K5 and C6   K7 SAA Flame proof and Intrinsic Safety Approvals  combination of I7  N7  and E7   Kg  ATEX Flame proof and Intrinsic Safety Approvals  combination of 11 and E8   Kp  CSA  FM  and ATEX Explosion proof and Intrinsic Safety Approval  combination of K5  C6  I1  and E8   I7 SAA Intrinsic Safety Certification  E7 SAA Flame proof Certification  N7 SAA Type N Certification  IA ATEX Intrinsic Safety for FISCO  for FOUNDATION fieldbus protocol only    Code Bolt for Flange and Adapters  Optional        L5 ASTM A 193  Grade B7M Bolts     e  1 Display Options       M5 LCD display for Aluminum Housing  Available with Housing codes A  B  C  and D only   M6 LCD display for SST Housing  Available with Housing codes J  K  L  and M only     Pressure 33    Product Data Sheet  00813 0100 4001  Rev HA  Rosemount 3051 Catalog 2008   2009    TABLE 13  3051L Flange Mounted Liquid Level Transmitter   e  1 Other Options    Q4 Calibration Data Sheet  Q8 Material Traceability Certification per EN 10204 3 1 B  Available with the diaphragm  upper housing  Coplanar flange  adapter   sensor module housing  lower housing flushing
28. The state of the art  fifth generation Rosemount 485 Annubar  combined with the 3051S or 3095MV MultiVariable transmitter  creates an accurate  repeatable and dependable insertion type  flowmeter     Compact Orifice Flowmeter Series  Rosemount  3051SFC  3095MFC  and 405    Compact Orifice Flowmeters can be installed between existing  flanges  up to a Class 600  PN100  rating  In tight fit applications   a conditioning orifice plate version is available  requiring only two  diameters of straight run upstream     ProPlate   Flowmeter Series  Rosemount ProPlate   Mass ProPlate  and 1195    These integral orifice flowmeters eliminate the inaccuracies that  become more pronounced in small orifice line installations  The  completely assembled  ready to install flowmeters reduce cost and  simplify installation     Product Data Sheet    00813 0100 4001  Rev HA  Catalog 2008   2009 Rosemount 3051    Product Offering    Rosemount 3051C Differential  Gage  and Absolute    See ordering information on page Pressure 25        Performance up to 0 04  accuracy  Installed five year stability of 0 125     Coplanar platform enables integrated manifold   primary element and diaphragm seal solutions  Calibrated spans ranges from 0 1 inH20 to 4000 psi   0 25 mbar to 276 bar     316L SST  Hastelloy  C276  Monef   Tantalum  Gold plated  Monel  or Gold plated 316L SST process isolators       Rosemount 3051T Gage and Absolute    See ordering information on page Pressure 29     Performance up to 0 0496
29. Transmitter   TE i  2  gt   AY  n   3 4 G5    s   2 inch U Bolt     for Pipe Mounting      o  z  I 5  z Lu H  o  s    o   a    3 3     lt     6 0  152      7  83        Dimensions are in inches  millimeters     Pressure 18    Product Data Sheet    00813 0100 4001  Rev HA    Catalog 2008   2009       Traditional Flange Panel    5 16 x 7 8 Bolts for Panel  Mounting  Not Supplied     N  PANEL MOUNTING  BRACKET       Rosemount 3051    Traditional Flange Mounting Configurations with  Optional Brackets for 2 in  Pipe or Panel Mounting    Mounting Bracket  option B2 B8                    10 1  257                 2 7   67                                              Traditional Flange 2 in  Pipe Mounting Bracket  option B1 B7 BA      lt 4 2  106      va Impulse Piping                                                      1 1  28   dk  95   ryt 9 6  DE   243   R p  67   i i Yy          1 4  33             4 6  116                 0 75  20   Clearance for  Cover Removal    Terminal  Connections   gt     114 18 NPT on  Traditional Flange for  Pressure Connection   Without the Use of  Flange Adapters   Connection Per IEC  61518 2 126  54    0 12 in  Connection  Centers                112 14 NPT  Conduit  Connection   Two Places  Other Sizes  Available     Transmitter    Adaptors Can  Be Rotated to  Give  Connection  Centers of 2 00   51   2 126  54    or 2 25  57          r    Circuitry  7 9  202   1 2 14 NPT on  Optional  Flange  1 7  43  Adapters     3         a Bodo    Housing  Rotati
30. a Sheet  00813 0100 4001  Rev HA  Rosemount 3051 Catalog 2008   2009    TABLE 11  3051C Differential  Gage  and Absolute Pressure Transmitters       Not Applicable       Applicable       Code Housing Material Conduit Entry Size cD fete  CA  A Polyurethane covered Aluminum 72 14 NPT        B Polyurethane covered Aluminum M20 x 1 5  CM20         C Polyurethane covered Aluminum PG 13 5        D Polyurethane covered Aluminum G         J SST 12 14 NPT        K SST M20 x 1 5  CM20         L SST PG 13 5        M SST G      c   Code PlantWeb Functionality  Optional  cD CG CA   A01 Advanced Control Function Block Suite        D01 FOUNDATION fieldbus Diagnostics Suite         Code Alternate Flange Options  Requires Materials of Construction Code 0  cD fete  CA  H2 Traditional Flange  316 SST  SST Drain Vent         H3  Traditional Flange  Alloy C  Hastelloy C276 Drain Vent        H4 Traditional Flange  Monel  Monel Drain Vent         H7  Traditional Flange  316 SST  Hastelloy C276 Drain Vent        HJ DIN Compliant Traditional Flange  SST  1146 in  Adapter Manifold Bolting         HK DIN Compliant Traditional Flange  SST  10 mm Adapter Manifold Bolting        HL DIN Compliant Traditional Flange  SST  12mm Adapter Manifold Bolting  Not available on 3051CD0         FA Level Flange  SST  2 in   ANSI Class 150  Vertical Mount        FB Level Flange  SST  2 in   ANSI Class 300  Vertical Mount        FC Level Flange  SST  3 in   ANSI Class 150  Vertical Mount        FD Level Flange  SST  3 i
31. an 0 005 in   0 08 cm      Damping   Analog output response to a step input change is user selectable  from 0 to 36 seconds for one time constant  This software damping  is in addition to sensor module response time     Pressure 10    Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009    PHYSICAL SPECIFICATIONS    Electrical Connections    112 14 NPT  PG 13 5  G1 2  and M20 x 1 5  CM20  conduit  HART  interface connections fixed to terminal block     Process Connections  All Models except 3051L and 3051T   14 18 NPT on 2  e in  centers   1 2 14 NPT on 2   21 8   or 21 4 in  centers  Rosemount 3051L    High pressure side  2   3   or 4 in   ASME B 16 5  ANSI  Class  150  300 or 600 flange  50  80 or 100 mm  PN 40 or 10 16 flange    Low pressure side    4 18 NPT on flange   2 14 NPT on adapter  Rosemount 3051T    1 2 14 NPT female  A DIN 16288 Male  available in SST for  Range 1 4 transmitters only   or Autoclave type F 250 C   Pressure relieved 16 18 gland thread  1 4 OD high pressure  tube 60   cone  available in SST for Range 5 transmitters only      Process Wetted Parts  Drain Vent Valves    316 SST  Hastelloy C276  or Monel material  Monel not  available with 3051L or 3051H     Process Flanges and Adapters    Plated carbon steel  SST cast CF 8M  cast version of 316 SST   material per ASTM A743   C Type cast alloy CW12MW  or  Monel cast alloy M30C    Wetted O rings  Glass filled PTFE or Graphite filled PTFE  Process Isolating Diaphragms       o   9   a   9  Iso
32. ans less than 5 1  accuracy    URL   2 0  015  0  oos  SE SRL  of Span  3051T  Ranges 1 4  0 065  of span Ranges 2 4  For spans less than 10 1  accuracy   High Accuracy Option  P8  URL  0 04  of span    0 0075  RL  J  of Span For spans less than 5 1  accuracy      0 0075  RL    of Span  Spa  Range 5  0 075  of span  For spans less than 10 1  accuracy    ss      0 0075                 of Span    E d 2  3051CA  Ranges 1 4  0 065  of span Ranges 2 4  For spans less than 10 1  accuracy   High Accuracy Option  P8  URL  0 04  of span  a o  o07s  SRE       of Span For spans less than 5 1  accuracy    s o oors  URL     of Span  Spa  3051H 3051L    All Ranges  0 075  of span  For spans less than 10 1  accuracy      fo  025   0 005  URL  met of Span     1  For FOUNDATION fieldbus transmitters  use calibrated range in place of span  For zero based spans  reference conditions  silicone oil fill  SST materials     Coplanar flange  3051C  or 1 2 in    18 NPT  3051T  process connections  digital trim values set to equal range points     Pressure 4    Product Data Sheet    00813 0100 4001  Rev HA  Catalog 2008   2009 Rosemount 3051    Total Performance  For  50   F  28   C  temperature changes  up to 1000 psi  6 9 MPa  line pressure  CD only   from 1 1 to 5 1 rangedown     Models Total Performance    3051C   Ranges 2 5  0 15  of span  3051T   Ranges 1 4  0 15  of span    Long Term Stability    Models Long Term Stability    3051C  Ranges 2 5  0 125  of URL for 5 years   50   F  28   C  temper
33. ature changes  and up to 1000 psi  6 9 MPa  line pressure   3051CD Low Draft Range  Ranges 0 1  0 2  of URL for 1 year  3051T  Ranges 1 4  0 125  of URL for 5 years   50   F  28   C  temperature changes  and up to 1000 psi  6 9 MPa  line pressure   Rosemount 3051H  Ranges 2 3  0 1  of URL for 1 year  Ranges 4 5 x0 296 of URL for 1 year    Dynamic Performance  4 20 mA Fieldbus     HART protocol  protocol   Typical HART Transmitter Response Time       Total Response Time  Tg   T         3051C  Ranges 2 5  100 ms 152 ms                            Range 1  255 ms 307 ms  Range 0  700 ms 752 ms Transmitter Output vs  Time  3051T  100 ms 152 ms Pressure Released  3051H L  Consult factory Consult factory T    Dead Time  Dead Time  Td  45 ms  nominal  97 ms am Time Constant  Update Rate 22 times per second 22 times per second 100  sponse Time   T4 T      1  Dead time and update rate apply to all models and ranges  analog output only   2  Nominal total response time at 75   F  24   C  reference conditions  36 8  fom   3  Transmitter fieldbus output only  segment macro cycle not included         63 2  of Total  Step Change    0           Time       Line Pressure Effect per 1000 psi  6 9 MPa   For line pressures above 2000 psi  13 7 MPa  and Ranges 4 5  see user manual  Rosemount publication number 00809 0100 4001    3051CD Zero Error  Range 0  0 125  of URL 100 psi  6 89 bar   Range 1  0 25  of URL 1000 psi  68 9 bar     Ranges 2 3  0 05  of URL 1000 psi  68 9 bar  for line pressures f
34. cable     Applicable           Code Mounting Bracket Options HD HG  B5 Universal Mounting Bracket for 2 in  Pipe or Panel Mount  CS Bolts      B6 Universal Mounting Bracket for 2 in  Pipe or Panel Mount  SST Bolts   2    Code Hazardous Locations Certification Options HD HG  E5 FM Explosion proof Approval      I5 FM Non incendive and Intrinsic Safety Approval      K5 FM Explosion proof and Intrinsic Safety Approval       14  ATEX Intrinsic Safety and Dust Certification       N10  ATEX Type N and Dust Certification      E8 ATEX Flame proof and Dust Certification       E40  TIIS Flame proof Certification      C6 CSA Explosion proof and Intrinsic Safety Approval   p   Ke 9 CSA and ATEX Explosion proof and Intrinsic Safety Approval  combination of C6 and K8       KB FM and CSA Explosion proof and Intrinsic Safety Approvals  combination of K5 and C6       K7 SAA Flame proof and Intrinsic Safety Approvals  combination of I7  N7  and E7        KB  ATEX Flame proof and Intrinsic Safety Approvals  combination of 11 and E8        KD    CSA  FM  and ATEX Explosion proof and Intrinsic Safety Approval  combination of K5  C6  11  and E8       I7 SAA Intrinsic Safety Certification      E7 SAA Flame proof Certification      N7 SAA Type N Certification      IA ATEX Intrinsic Safety for FISCO  for FOUNDATION fieldbus protocol only      IE FM FISCO Intrinsic Safety  for FOUNDATION fieldbus protocol only                Code Bolt for Flange and Adapter Options HD HG  L4 Austenitic 316 SST Bolts G 
35. ied thread  adaptor     N7 SAA Type n  Non sparking   Certification No   AUS Ex 1249X  Ex n IIC T4  Tamb   70   C   IP66    Special Conditions for Safe Use  X     Where the equipment is installed such that there is an  unused conduit entry  it must be sealed with a suitable  blanking plug to maintain the IP40 degree of protection  Any  blanking plug used with the equipment shall be of a type  which requires the use of a tool to effect its removal  Voltage  source shall not exceed 35V dc     Combinations of Certifications   Stainless steel certification tag is provided when optional approval  is specified  Once a device labeled with multiple approval types is  installed  it should not be reinstalled using any other approval  types  Permanently mark the approval label to distinguish it from  unused approval types     K5 E5 and 15 combination   KB K5 and C6 combination   KD K5  C6  11  and E8 combination  K6  C6 11  and E8 combination   K8 E8 and 11 combination   K7 E7  17  and N7 combination    Product Data Sheet  00813 0100 4001  Rev HA    Catalog 2008   2009 Rosemount 3051    Dimensional Drawings    3051 Exploded View       Certification Label                 Span and Zero Adjustments    Standard     Electronics Housing    Terminal Block    Cover O ring    Cover    lectronics Board     a    Housing Rotation Set Screw   180  Maximum Housing Rotation  without Further Disassembly     Coplanar Flange    Drain Vent Valve    Flange Adapter O Ring    Flange Alignment Screw   Not Pre
36. ilable with HART Option Code A      m   C5  Measurement Canada Accuracy Approval  Limited availability depending on transmitter type and range  Eg 2 E   Contact an Emerson Process Management representative   C6 CSA Explosion proof and Intrinsic Safety Approval         K6    CSA and ATEX Explosion proof and Intrinsic Safety Approval  combination of C6 and K8     gt     KB FM and CSA Explosion proof and Intrinsic Safety Approvals  combination of K5 and C6         K7 SAA Flame proof and Intrinsic Safety Approvals  combination of I7  N7  and E7  t       K8    ATEX Flame proof and Intrinsic Safety Approvals  combination of 11 and E8      9   KD  FM  CSA  and ATEX Explosion proof and Intrinsically Safe combination of K5  C6  11  and E8 E i I  I7 SAA Intrinsic Safety Certification i   y  E7 SAA Flame proof Certification   g      N7 SAA Type N Certification     y  IA ATEX Intrinsic Safety for FISCO  for FOUNDATION fieldbus protocol only   t     Code Bolting Options  04B  fore   07   L4 Austenitic 316 SST Bolts        L5 ASTM A 193  Grade B7M Bolts        L6 Monel Bolts         Code Display Options cD fete   07   M5 LCD display for Aluminum Housing  Housing Codes A  B  C  and D only         M6 LCD display for SST Housing  Housing Codes J  K  L  and M only           Pressure 27    Product Data Sheet  00813 0100 4001  Rev HA  Rosemount 3051 Catalog 2008   2009    TABLE 11  3051C Differential  Gage  and Absolute Pressure Transmitters       Not Applicable       Applicable    Code Other Op
37. im the pressure sensor or recall  factory defaults     LCD Block  Configures the local display     2 Analog Input Blocks  Processes the measurements for input into other function  blocks  The output value is in engineering units or custom and  contains a status indicating measurement quality     PID Block    Contains all logic to perform PID control in the field including  cascade and feedforward     Backup Link Active Scheduler  LAS     The transmitter can function as a Link Active Scheduler if the  current link master device fails or is removed from the segment     Advanced Control Function Block Suite  Option Code A01   Input Selector Block    Selects between inputs and generates an output using specific  selection strategies such as minimum  maximum  midpoint   average or first    good       Arithmetic Block    Provides pre defined application based equations including flow  with partial density compensation  electronic remote seals   hydrostatic tank gauging  ratio control and others    Signal Characterizer Block  Characterizes or approximates any function that defines an  input output relationship by configuring up to twenty X  Y  coordinates  The block interpolates an output value for a given  input value using the curve defined by the configured  coordinates    Integrator Block    Compares the integrated or accumulated value from one or two  variables to pre trip and trip limits and generates discrete output  signals when the limits are reached  This block is useful f
38. isplay for SST Housing  Housing Codes J  K  L and M only   T1 Transient Protection Terminal Block   C16  Custom Software Configuration  Completed CDS 00806 0100 4001 required with order    C20  0 8 3 2 V dc Output with Digital Signal Based on HART Protocol  Output Code M only   c47  Analog Output Levels Compliant with NAMUR Recommendation NE 43  27 June 1996   CN  7  Analog Output Levels Compliant with NAMUR Recommendation NE 43  Low Alarm Configuration   P1 Hydrostatic Testing with Certificate   P2 Cleaning for Special Service   P3 Cleaning for   1 PPM Chlorine Fluorine   P8 0 0496 accuracy to 5 1 turndown  Range 1 4    V5 9 External Ground Screw Assembly  Typical Model Number  30511 G 5 F 2A 2 1 A B4        1  3051TG lower range limit varies with atmospheric pressure      2  Materials of Construction comply with recommendations per NACE MR0175 ISO 15156 for sour oil field production environments  Environmental limits  apply to certain materials  Consult latest standard for details  Selected materials also conform to NACE MRO0103 for sour refining environments      3     Assemble to    items are specified separately and require a completed model number     4  Not available with low power Option Code M     5  Not available with fieldbus  output code F  or Profibus protocols  output code W      6  Local zero and span adjustments are standard unless Option Code J1 or J3 is specified     7  NAMUR Compliant operation is pre set at the factory and cannot be changed to standard ope
39. k of 3M Company     All other marks are the property of their respective owners   Rosemount Model 3051 Smart Pressure Transmitters may be protected by one or more of the following U S  Patent Nos  4 370 890  4 466 290     4 612 812  4 791 352  4 798 089  4 818 994  4 833 922  4 866 435  4 926 340  4 988 990  and 5 028 746  Mexico Patentado No  154 961  May  depend on model  Other foreign patents issued and pending     Emerson Process Management    Rosemount Inc  Emerson Process Management Emerson Process Management Asia  8200 Market Boulevard Heath Place Pacific Private Limited  Chanhassen  MN 55317 USA Bognor Regis 1 Pandan Crescent  T  U S   1 800 999 9307 West Sussex PO22 9SH Singapore 128461  T  International   952  906 8888 England T  65  6777 8211  F  952  949 7001 T 44  0  1243 863121 F  65  6777 0947  F 44  0  1243 867554 Enquiries AP EmersonProcess com    www rosemount com    TRA EMERSON        2008 Rosemount Inc  All rights reserved  Process Management       
40. lating Diaphragm Material S  316L SST           Hastelloy C276          Monel      Tantalum      Gold plated Monel      Gold plated SST        Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009    Rosemount 3051L Process Wetted Parts   Flanged Process Connection  Transmitter High Side   Process Diaphragms  Including Process Gasket Surface    316L SST  Hastelloy C276  or Tantalum  Extension      CF 3M  Cast version of 316L SST  material per ASTM A743      or Hastelloy C276  Fits schedule 40 and 80 pipe   Mounting Flange    Zinc cobalt plated CS or SST  Reference Process Connection  Transmitter Low Side   Isolating Diaphragms    316L SST or Hastelloy C276  Reference Flange and Adapter    CF 8M  Cast version of 316 SST  material per ASTM A743     Non Wetted Parts  Electronics Housing    Low copper aluminum or CF 3M  Cast version of 316L SST   material per ASTM A743   NEMA 4X  IP 65  IP 66    Coplanar Sensor Module Housing  CF 3M  Cast version of 316L SST  material per ASTM A743   Bolts    ASTM A449  Type 1  zinc cobalt plated carbon steel   ASTM F593G  Condition CW1  Austenitic 316 SST   ASTM A193  Grade B7M  zinc plated alloy steel   Monel K 500    Sensor Module Fill Fluid    Silicone oil  D C  200  or Fluorocarbon oil  Halocarbon or  Fluorinert   FC 43 for 3051T     Process Fill Fluid  3051L and 3051H only     3051L  Syltherm XLT  D C  Silicone 704   D C  Silicone 200  inert  glycerin and water  Neobee M 20 or  propylene glycol and water    3051H  inert  Neobee M
41. meters       Output Information     Transmitter Information     LCD display Configuration     Hardware Selectable Information    Signal Selection    Refer to the  HART Protocol C1 Option Configuration Data Sheet   document number 00806 0100 4001     Tagging  3 options available      Standard SST hardware tag is wired to the transmitter  Tag  character height is 0 125 in   3 18 mm   56 characters  maximum      Tag may be permanently stamped on transmitter nameplate  upon request  56 characters maximum      Tag may be stored in transmitter memory  30 characters  maximum   Software tag is left blank unless specified     Commissioning tag  fieldbus only     A temporary commissioning tag is attached to all transmitters  The  tag indicates the device ID and allows an area for writing the  location     Optional Rosemount 304  305 or 306 Integral Manifolds    Factory assembled to 3051C and 3051T transmitters  Refer to the  following Product Data Sheet  document number  00813 0100 4839 for Rosemount 304 and 00813 0100 4733 for  Rosemount 305 and 306  for additional information      1  Not applicable to fieldbus     Rosemount 3051    Optional Diaphragm and Sanitary Seals    Refer to Product Data Sheet 00813 0100 4016 or  00813 0201 4016  for additional information     Output Information    Output range points must be the same unit of measure  Available  units of measure include     inH20 inH20 4   c   psi Pa  inHg ftH20 bar kPa  mmH20 mmH20 4   c   mbar torr  mmHg g cm2 kg cm2 atm     
42. n   ANSI Class 300  Vertical Mount        FP DIN Level Flange  SST  DN 50  PN 40  Vertical Mount        FQ DIN Level Flange  SST  DN 80  PN 40  Vertical Mount         Code Integral Mount Manifold Options  Requires Materials of Construction Code 0    S5 Assemble to Rosemount 305 Integral Manifold  specified separately  see the Rosemount 305 and 306         Integral Manifolds PDS  document number 00813 0100 4733      s6    Assemble to Rosemount 304 Manifold or connection system      Code Integral Mount Primary Elements  Optional  cD fete   07   S4 F         m    actory Assembly to Rosemount Primary Element  Orifice    With the primary element installed  the maximum operating pressure will equal the lesser of  either the transmitter or the primary element  Option is available for factory assembly to range 1   4  transmitters only      3  Factory Assembly to Rosemount 405 Primary Element M        Rosemount Annubar or Rosemount 1195 Integral    Diaphragm Seal Assemblies  Optional        NOTE  Standard flange and adapter bolts are austenitic 316 SST   S1 One Diaphragm Seal  Direct Mount or Capillary Connection Type         S20 Two Diaphragm Seals  Direct Mount or Capillary Connection Type             Optional All Welded Diaphragm Seal Systems  for high vacuum applications     NOTE  Standard flange and adapter bolts are austenitic 316 SST        S7 One Diaphragm Seal  All Welded System  Capillary Connection Type         S80 Two Diaphragm Seals  All Welded System  Capillary Connectio
43. n 10 5 to 55 V dc with no load     Load Limitations    Maximum loop resistance is determined by the voltage level of  the external power supply  as described by     Max  Loop Resistance   43 5  Power Supply Voltage     10 5        1935    1500    1000            Operating    Region         500    Load  Ohms           20 30 40  42 4       Voltage  V dc     Communication requires a minimum  loop resistance of 250 ohms     55     1  For CSA approval  power supply must not exceed 42 4 V     FOUNDATION fieldbus  output code F  and  Profibus  output code W   Power Supply    External power supply required  transmitters operate on 9 0 to  32 0 V dc transmitter terminal voltage     Current Draw  17 5 mA for all configurations  including LCD display option     FOUNDATION fieldbus Function Block Execution Times    Block Execution Time    Resource    Transducer    LCD Block    Analog Input 1  2 30 milliseconds  PID 45 milliseconds  Input Selector 30 milliseconds  Arithmetic 35 milliseconds  Signal Characterizer 40 milliseconds  Integrator 35 milliseconds    Pressure 8    Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009    FOUNDATION fieldbus Parameters    Schedule Entries 7  max    Links 20  max    Virtual Communications Relationships  VCR  12  max      Standard Function Blocks    Resource Block  Contains hardware  electronics  and diagnostic information     Transducer Block    Contains actual sensor measurement data including the sensor  diagnostics and the ability to tr
44. n Type             so  One Diaphragm Seal  All Welded System  Direct Mount Connection Type         S99   Two Diaphragm Seals  All Welded System  One Direct Mount and One Capillary Connection Type               Pressure 26    Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009 Rosemount 3051    TABLE 11  3051C Differential  Gage  and Absolute Pressure Transmitters       Not Applicable       Applicable    Code Mounting Bracket Options cD CG CA  B4 Coplanar Flange Bracket for 2 in  Pipe or Panel Mounting  all SST        B1 Traditional Flange Bracket for 2 in  Pipe Mounting  CS Bolts        B2 Traditional Flange Bracket for Panel Mounting  CS Bolts        B3 Traditional Flange Flat Bracket for 2 in  Pipe Mounting  CS Bolts        B7 B1 Bracket with Series 300 SST Bolts        B8 B2 Bracket with Series 300 SST Bolts        B9 B3 Bracket with Series 300 SST Bolts        BA SST B1 Bracket with Series 300 SST Bolts        BC SST B3 Bracket with Series 300 SST Bolts         Code Hazardous Locations Certification Options CD CG CA  E5 FM Explosionproof Approval        15 FM Non incendive and Intrinsic Safety Approval        IE FM FISCO Intrinsically Safe  for FOUNDATION fieldbus protocol only        K5 FM Explosionproof and Intrinsic Safety Approval        16  ATEX Intrinsic Safety G       N19 ATEX Type N and Dust Certification        E8 ATEX Flame proof and Dust Certification         E40 TIIS Flame proof Certification 2   g  14 TIIS Intrinsic Safety Certification  Only ava
45. n transmitter type and range  Contact an Emerson  Process Management representative   C6 CSA Explosion proof and Intrinsic Safety Approval  K6W  CSA and ATEX Explosion proof and Intrinsic Safety Approval  combination of C6 and K8   KB FM and CSA Explosion proof and Intrinsic Safety Approvals  combination of K5 and C6   K7 SAA Flame proof and Intrinsic Safety Approvals  combination of 17  N7  and E7   K8   ATEX Flame proof and Intrinsic Safety Approvals  combination of 11 and E8   KD     CSA  FM  and ATEX Explosion proof and Intrinsic Safety Approval  combination of K5  C6  11  and E8   I7 SAA Intrinsic Safety Certification  E4  TIIS Flame proof Certification  E7 SAA Flame proof Certification  N7 SAA Type N Certification  I1  ATEX Intrinsic Safety and Dust Certification  N1   ATEX Type N and Dust Certification  E8 ATEX Flame proof and Dust Certification  DW NSF drinking water approval  IA ATEX Intrinsic Safety for FISCO  for FOUNDATION fieldbus protocol only    Code Other Options    Q4 Calibration Data Sheet  Q8 Material Traceability Certification per EN 10204 3 1 B NOTE  This option applies to the process connection only   Q16 Surface finish certification for sanitary remote seals  Qz Remote Seal System Performance Calculation Report  QP Calibration certification and tamper evident seal  QS Certificate of FMEDA Data  J1  X6    ocal Zero Adjustment Only  J3  X    No Local Zero or Span Adjustment  M5 LCD display for Aluminum Housing  Housing Codes A  B  C  and D only   M6 LCD d
46. nctionality  The 3051 powers the PlantWeb  Y v architecture by delivering the best  POWERS     Sensor and transmitter  best installation  PlantWeh practices  and best in class field  intelligence  One component is the  enhanced diagnostic capabilities in  FOUNDATION fieldbus that provide an increase in  process visibility  enabling proactive maintenance   improving process availability and plant productivity     o     Rosemount Pressure Solutions    Rosemount 3051S Series of Instrumentation  Scalable pressure  flow and level measurement solutions improve  installation and maintenance practices     Rosemount 3095MV Mass Flow Transmitter   Accurately measures differential pressure  static pressure and  process temperature to dynamically calculate fully compensated  mass flow     Rosemount 305 and 306 Integral Manifolds  Factory assembled  calibrated and seal tested manifolds reduce  on site installation costs     Rosemount 1199 Diaphragm Seals  Provides reliable  remote measurements of process pressure and  protects the transmitter from hot  corrosive  or viscous fluids     Orifice Plate Primary Element Systems  Rosemount  1495 and 1595 Orifice Plates  1496 Flange Unions and  1497 Meter Sections   A comprehensive offering of orifice plates  flange unions and  meter sections that is easy to specify and order  The 1595  Conditioning Orifice provides superior performance in tight fit  applications     Pressure 2    Annubar  Flowmeter Series  Rosemount 3051SFA   3095MFA  and 485   
47. needed with the T1 option  external ground screw assembly is included with the T1 option      7  Not available with Option Codes AO  BO  and GO     Pressure 34    Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009 Rosemount 3051    TABLE 14  3051H Pressure Transmitter for High Temperature Processes       Not Applicable       Applicable                            Model Transmitter Type  Select One  HD HG  3051HD Differential Pressure Transmitter for High Temperature Processes        3051HG Gage Pressure Transmitter for High Temperature Processes         Code Pressure Ranges  Range  Min  Span    3051HD 3051HG   2    250 to 250 inH20 2 5 inH2O    250 to 250 inH20 2 5 inH2O    0 62 to 0 62 bar 6 2 mbar    0 62 to 0 62 bar 6 2 mbar    3    1000 to 1000 inH2O 10 inH2O    407 to 1000 inH2O 10in H2O    2 5 to 2 5 bar 25 mbar   71 01 to 2 5 bar 25 mbar    4    300 to 300 inH2O 3 psi    14 7 to 300 psi 3 psi    747 to 747 mbar 0 2 bar   71 01 to 20 7 bar 0 2 bar    5    2000 to 2000 psi 20 psi    14 7 to 2000 psig 20 psi   7138 to 138 bar 1 4 bar   71 01 to 138 bar 1 4 bar    NOTE  3051HG lower range limit varies with atmospheric pressure    Code Output HD HG  A 4 20 mA with Digital Signal Based on HART Protocol      M Low Power 1 5 V dc with Digital Signal Based on HART Protocol  See Option Code C2 for 0 8   3 2 V dc Output         Not available with hazardous certification Option Codes 11  N1  E4  K6  and K8    F FOUNDATION fieldbus Protocol      W Profibus     PA      
48. nmental limits apply  to certain materials  Consult latest standard for details  Selected materials also conform to NACE MR0103 for sour refining environments      2     Assemble to    items are specified separately and require a completed model number     3  Not available with low power Option Code M     4  Not available with fieldbus  output code F  or profibus protocols  output code W      5  NAMUR Compliant operation is pre set at the factory and cannot be changed to standard operation in the field      6  The V5 option is not needed with the T1 option  external ground screw assembly is included with the T1 option     Pressure 36    Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009    OPTIONS    Standard Configuration    Unless otherwise specified  transmitter is shipped  as follows     ENGINEERING UNITS    Differential Gage  inH20  Range 0  1  2  and 3  psi   Range 4 and 5   Absolute 3051T  psi  all ranges     4 mA  1 V dc     0  engineering units above   20 mA  5 V dc   Upper range limit   Output  Linear   Flange type  Specified model code option  Flange material  Specified model code option  O ring material  Specified model code option    Drain vent  Specified model code option  Integral meter  Installed or none   Alarm    Upscale   Software tag   Blank      1  Not applicable to fieldbus     Custom Configuration HART protocol only     If Option Code C1 is ordered  the customer may specify the  following data in addition to the standard configuration para
49. not capable of withstanding a  500V r m s  test to case  This must be taken into account on  any installation in which it is used  for example by assuring  that the supply to the apparatus is galvanically isolated     ATEX Flame Proof and Dust   Certification No   KEMA 00ATEX2013X     II 1 2 GD  EEx d IIC T6   50  lt  T4  lt  65   C    Dust rating T90   C  IP66   ce 1180   Vmax   55 V dc    Special Conditions for Safe Use  X     This device contains a thin wall diaphragm  Installation   maintenance  and use shall take into account the  environmental conditions to which the diaphragm will be  subjected  The manufacturer   s instructions for installation  and maintenance shall be followed in detail to assure safety  during its expected lifetime     Rosemount 3051    Japanese Certifications    E4    TIIS Flame Proof    Ex d IIC T6   Certificate Description   C15850 3051C D 1 4   20 mA HART      no display   C15851 3051C D 1 4   20 mA HART      with display   C15854 3051T G 1 4   20 mA HART  SST  Silicon      no display   C15855 3051T G 1 4 20 mA HART  Hastelloy C276   Silicon     no display   C15856 3051T G 1 4 20 mA HART  SST  Silicon      with display   C15857 3051T G 1 4 20 mA HART  Hastelloy C276     Silicon     with display  TIIS Intrinsic Safety    Ex ia IIC T4  Certificate Description  C16406 3051CD CG    Australian Certifications    I7    SAA Intrinsic Safety   Certification No   AUS Ex 1249X   Ex ia IIC T4  Tamb   70   C    IP66   When connected per Rosemount drawing 03
50. ode Fill Fluid    1 Silicone  2 Inert  Fluorinert   FC 43                   Code Housing Material Conduit Entry Size  A Polyurethane covered Aluminum      14 NPT  B Polyurethane covered Aluminum M20 x 1 5  CM20   C Polyurethane covered Aluminum PG 13 5  D Polyurethane covered Aluminum G   J SST 72 14 NPT  K SST M20 x 1 5  CM20   L SST PG 13 5    M    SST G   Code  PlantWeb Functionality  Optional   A01 Advanced Control Function Block Suite  D01 FOUNDATION fieldbus Diagnostics Suite  Code Integral Mount Manifold  Optional           S5 Assemble to Rosemount 306 Integral Manifold  specified separately  see the Rosemount 305 and 306 Integral  Manifolds PDS  document number 00813 0100 4733    Requires 1 2 in  process connection code 2B        Code Remote Diaphragm Seals Assemblies  Optional     S1 One remote diaphragm seal  Direct Mount or Capillary Connection Type   Requires Process Connection Style code 2B   Code Mounting Brackets  Optional   B4 Bracket for 2 in  Pipe or Panel Mounting  All SST    Pressure 29    Product Data Sheet  00813 0100 4001  Rev HA  Rosemount 3051 Catalog 2008   2009    TABLE 12  3051T Gage and Absolute Pressure Transmitter    Code Hazardous Locations Certifications  Optional     E5 FM Explosion proof Approval  I5 FM Non incendive and Intrinsic Safety Approval  IE FM FISCO Intrinsically Safe  for FOUNDATION fieldbus protocol only  K5 FM Explosion proof and Intrinsic Safety Approval  C5 Measurement Canada accuracy approval  Limited availability depending o
51. on  Set Screw          Dimensions are in inches  millimeters     Pressure 19          Product Data Sheet  00813 0100 4001  Rev HA  Rosemount 3051 Catalog 2008   2009    3051T Dimensional Drawings    1 2 14 NPT  Conduit Certification    Connection  Two Label    Places  Other 4 1  105   Sizes Available   ESNY  Was ZEN                        0 75  20   Clearance  for Cover  Removal    0 75 20      Clearance for  FY  Cover Removal j        Transmitter   Circuitry     183           Housing  Rotation  Set Screw          3051T Typical Mounting Configurations with Optional Mounting Bracket                                                                               Pipe Mounting Panel Mounting  Arn  ww  Ex min Z     O  rm 2  6  2   156     O  E ju g  le 6 3 G  3 5  160        o    f  4 8  120      gt   6 9 175                    Dimensions are in inches  millimeters     Pressure 20    Product Data Sheet    00813 0100 4001  Rev HA  Catalog 2008   2009 Rosemount 3051    3051H Pressure Transmitter Exploded View and Dimensional Drawings          Secondary  Filled System    High Side Process Flange    Process Isolating Diaphragm    Low Side Process Flange    Drain Vent Valve              Flange Bolts  1   2 14 NPT  5 0  127  Conduit Connection 4 1  105  Certification   Two Places  Other Label  4 3  110  Sizes Available            0 75  19   Clearance for  Cover Removal    0 75  19  Clearance     for Cover Removal                         Transmitter     Dates   Terminal  Circuitry CN    C
52. onnections          Housing Rotation  Set Screw          Nameplate    _                   Drain Vent  Valve                   1 2 3 4 1 1           30   86   28  A  112 14 NPT on Optional Mounting Adapters   1 2 18 NPT on Process Flange for Pressure Connection Adapters Can Be Rotated    Without the Use of Mounting Adapters to Give Adapter Connection Centers of 2 00  51    2 126  54   or 2 25  57                  Dimensions are in inches  millimeters     Pressure 21    Product Data Sheet  00813 0100 4001  Rev HA  Rosemount 3051 Catalog 2008   2009    3051H Mounting Brackets for 2 in  Pipe and Panel Mount  Option Code B5 B6                        PIPE MOUNTING CONFIGURATION           0 7  16              4 4  109        Impulse Piping                                                 PANEL MOUNTING CONFIGURATION  746 20x3 4 Bolts Supplied for  Attaching Bracket to Transmitter                   Dimensions are in inches  millimeters     Pressure 22    Product Data Sheet    00813 0100 4001  Rev HA  Catalog 2008   2009 Rosemount 3051    3051L Dimensional Drawings    2 in  Flange Configuring  Flush Mount Only  3  and 4 in  Flange Configuration       4 1  104  4 1  104     Housing  Rotation  Set  Screw      il    A H A  Extension H  H 2  4  or 6  51  102  or 152                                                  Flushing Connection    Diaphragm Assembly and  Mounting Flange                            Dimensions are in inches  millimeters     Pressure 23    Product Data Sheet  00813 0100 
53. option 3 in   600 25 2  11 4  27 2  12 3  28 2 12 8  29 2  13 2      Bracket for mounting on 2 in  pipe DN 50 PN 40 13 8  6 2                 Carbon steel construction with carbon DN 80 PN 40 19 5  8 8  21 5  9 7  22 5 10 2  23 5  10 6   steel bolts DN 100  17 8  8 1  19 8  9 0  20 8  9 5  21 8  9 9      Coated with polyurethane paint PN 10 16  B2 Bracket for Panel Mounting DN 100  23 2  10 5  25 2  11 5  26 2  11 9  27 2  12 3   PN 40      For use with the traditional flange option      Bracket for mounting transmitter on wall  or panel      Carbon steel construction with carbon TABLE 17  Transmitter Options Weights    steel bolts Add    Coated with polyurethane paint Code Option Ib  kg   B3 Flat Bracket for 2 in  Pipe Mounting J K  LM Stainless Steel Housing T  3 9  1 8     For use with the traditional flange option J K L M Stainless Steel Housing  C  L  H  P  3 1  1 4     Bracket for vertical mounting of transmitter on 2 in  pipe M5 LCD display for Aluminum Housing 0 5  0 2     Carbon steel construction with carbon M6 LCD display for SST Housing 1 25  0 6   steel bolts B4 SST Mounting Bracket for CoplanarFlange 1 0  0 5     Coated with polyurethane paint B1B2B3 Mounting Bracket for Traditional Flange 2 3  1 0   B7 B1 Bracket with SST Bolts B7 B8 B9 Mounting Bracket for Traditional Flange 2 3  1 0     Same bracket as the B1 option with Series 300 stainless steel BA BC SST Bracket for Traditional Flange 2 3  1 0   bolts B5B6 Mounting Bracket for 3051H 2 9  1 3   B8 B2 Bracke
54. or  calculating total flow  total mass  or volume over time     FOUNDATION fieldbus Diagnostics Suite  Option Code D01     The 3051C FOUNDATION fieldbus Diagnostics provide Abnormal  Situation Prevention  ASP  indictation  The integral statistical  process monitoring  SPM  technology calculates the mean and  standard deviation of the process variable 22 times per second   The 3051C ASP algorithm uses these values and highly flexible  configuration options for customization to many user defined or  application specific abnormal situations  The detection of  plugged impulse lines is the first available predefined  application     Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009    Low Power  Output Code M     Output    Three wire 1   5 V dc or 0 8   3 2 V dc  Option Code C2   user selectable output  Also user selectable for linear or square  root output configuration  Digital process variable superimposed  on voltage signal  available to any host conforming to the HART  protocol  Low power transmitter operates on 6   12 V dc with no  load     Power Consumption  3 0 mA  18 36 mW    Minimum Load Impedance  100 KQ  Vout wiring     Indication  Optional 5 digit LCD display    Overpressure Limits  Rosemount 3051CD CG     Range 0  750 psi  51 7 bar      Range 1  2000 psig  137 9 bar       Ranges 2   5  3626 psig  250 bar   4500 psig  310 3 bar  for option code P9    Rosemount 3051CA     Range 1  750 psia  51 7 bar      Range 2  1500 psia  103 4 bar      Range 3  1600 p
55. ration in the field      8  The V5 option is not needed with T1 option  external ground screw assembly is included with the T1 option     Pressure 30    Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009 Rosemount 3051    TABLE 13  3051L Flange Mounted Liquid Level Transmitter  Model Transmitter Type    3051L Flange Mounted Liquid Level Transmitter    Code Pressure Ranges  Range Min  Span              2    250 to 250 inH20 2 5 inH2O     0 6 to 0 6 bar 6 2 mbar   3    1000 to 1000 inH2O 10 inH2O   2 5 to 2 5 bar 25 mbar   4    300 to 300 psi 3 psi   20 7 to 20 7 bar 0 2 bar    e  1 Output  A 4   20 mA with Digital Signal Based on HART Protocol  M Low Power 1 5 V dc with Digital Signal Based on HART Protocol  See Option Code C2 for 0 8 3 2 V dc Output    Not available with hazardous certification Option Codes I1  N1  E4  K6  and K8   F FOUNDATION fieldbus Protocol  Ww Profibus     PA  High Pressure Side   e  1 Diaphragm Size Material Extension Length  GO 2 in  DN 50 316L SST Flush Mount Only  HO 2 in  DN 50 Hastelloy C276 Flush Mount Only  JO 2 in  DN 50 Tantalum Flush Mount Only  AO 3 in  DN 80 316L SST Flush Mount  A2 3 in  DN 80 316L SST 2 in  50 mm  A4 3 in  DN 80 316L SST 4 in  100 mm  A6 3 in  DN 80 316L SST 6 in  150 mm  BO 4 in  DN 100 316L SST Flush Mount  B2 4 in  DN 100 316L SST 2 in  50 mm  B4 4 in  DN 100 316L SST 4 in  100 mm  B6 4 in  DN 100 316L SST 6 in  150 mm  CO 3 in  DN 80 Hastelloy C276 Flush Mount  C2 3 in  DN 80 Hastelloy C276 2 in  50 mm  
56. rocess Fill Fluid   D C   Silicone 200    40 to 375   F   40 to 191   C     Inert     50 to 350   F   45 to 177   C   Neobee M 20    0 to 375   F   18 to 191   C     3051T  Process Fill Fluid   Silicone Fill Sensor    40 to 250   F   40 to 121   C     Inert Fill Sensor     22 to 250   F   30 to 121   C     3051L Low Side  Temperature Limits   Silicone Fill Sensor    40 to 250   F   40 to 121   C   Inert Fill Sensor  0 to 185   F   18 to 85   C  2   3051L High Side Temperature Limits  Process Fill Fluid   Syltherm   XLT    100 to 300   F   73 to 149   C   D C  Silicone 704   32 to 400   F  0 to 205   C   D C  Silicone 200    40 to 400   F   40 to 205   C   Inert    50 to 350   F     45 to 177   C   Glycerin and Water 0 to 200   F   18 to 93   C   Neobee M 20 0 to 400   F   18 to 205   C   Propylene Glycol and Water 0 to 200   F   18 to 93   C                             1  Process temperatures above 185   F  85   C  require derating the  ambient limits by a 1 5 1 ratio  0 6 1 ratio for the 3051H       2  220   F  104   C  limit in vacuum service  130   F  54   C  for  pressures below 0 5 psia      3  3051CDO process temperature limits are    40 to 212   F    45 to 100   C      4  160   F  71   C  limit in vacuum service    5  Not available for 3051CA   Humidity Limits  0   100  relative humidity    Turn On Time    Performance within specifications less than 2 0 seconds  10 0 s  for Profibus protocol  after power is applied to the transmitter    Volumetric Displacement  Less th
57. rom 0 to 2000 psi  0 to 13 7 MPa     Span Error  Range 0  0 15  of reading 100 psi  6 89 bar   Range 1  0 4  of reading 1000 psi  68 9 bar   Ranges 2 3 x0 196 of reading 1000 psi  68 9 bar   3051HD Zero Error   All Ranges 0 176 of URL 1000 psi  68 9 bar  for line pressures from 0 to 2000 psi  0 to 13 7 MPa     Span Error  All Ranges  0 1  of reading 1000 psi  68 9 bar      1  Can be calibrated out at line pressure     Pressure 5    Product Data Sheet  00813 0100 4001  Rev HA    Rosemount 3051 Catalog 2008   2009    Ambient Temperature Effect per 50  F  28  C     Models Ambient Temperature Effect    3051CD CG  Range 0   0 25  URL   0 05  span     Range 1    0 1  URL   0 25  span     Ranges 2 5   0 0125  URL   0 0625  span  from 1 1 to 5 1    0 025  URL   0 125  span  from 5 1 to 100 1    3051T  Range 1   0 025  URL   0 125  span  from 1 1 to 10 1    0 05  URL   0 125  span  from 10 1 to 100 1  Range 2 4   0 025  URL   0 125  span  from 1 1 to 30 1    0 035  URL   0 125  span  from 30 1 to 100 1  Range 5   0 1  URL   0 15  span     3051CA  All Ranges   0 025  URL   0 125  span  from 1 1 to 30 1      0 035  URL   0 125  span  from 30 1 to 100 1    3051H  All Ranges   0 025  URL   0 125  span   0 35 inH2O  from 1 1 to 30 1      0 035  URL   0 125  span   0 35 inH2O  from 1 1 to 30 1  3051L See Rosemount Inc  Instrument Toolkit  software     Mounting Position Effects    Models Mounting Position Effects   3051C Zero shifts up to  1 25 inH20  3 11 mbar   which can be calibrated out 
58. s meet all of the requirements of  EN61326  1997   A1  A2  and A3 and NAMUR NE 21    Ordinary Location Certification for Factory Mutual  As standard  the transmitter has been examined and tested to  determine that the design meets basic electrical  mechanical   and fire protection requirements by FM  a nationally recognized  testing laboratory  NRTL  as accredited by the Federal  Occupational Safety and Health Administration  OSHA      Pressure 12    HART PROTOCOL    Hazardous Locations Certifications  North American Certifications    FM Approvals    E5  Explosion Proof for Class I  Division 1  Groups B  C  and D   Dust Ignition Proof for Class II  Division 1  Groups E  F  and  G  Dust Ignition Proof for Class III  Division 1   Factory Sealed  Enclosure Type 4X    15 Intrinsically Safe for use in Class I  Division 1  Groups A  B   C  and D  Class II  Division 1  Groups E  F  and G  Class III   Division 1 when connected per Rosemount drawing  03031 1019  Non incendive for Class I  Division 2  Groups  A  B  C  and D    Temperature Code T4  Ta   40   C   T3  Ta   85   C    Enclosure Type 4X  For input parameters see control drawing 03031 1019     Canadian Standards Association  CSA     E6  Explosion Proof for Class I  Division 1  Groups B  C  and D   Dust Ignition Proof for Class II and Class III  Division 1   Groups E  F  and G  Suitable for Class I  Division 2 Groups  A  B  C  and D for indoor and outdoor hazardous locations   Enclosure type 4X  factory sealed    C6  Explosion
59. s transmitter failure  the analog  signal will be driven either below 3 75 mA or to 21 75 mA to alert  the user  NAMUR compliant values are available  option code  C4  High or low alarm signal is user selectable by internal  jumper    Output Code M  If self diagnostics detect a gross transmitter failure  the analog  signal will be driven either below 0 94 V or above 5 4 V to alert  the user  below 0 75 V or above 4 4 V for Option C2   High or  low alarm signal is user selectable by internal jumper    Output Code F and W  If self diagnostics detect a gross transmitter failure  that  information gets passed as a status along with the process  variable     Temperature Limits  Ambient       40 to 185   F   40 to 85   C    With LCD display       4 to 175   F   20 to 80   C   Storage      50 to 230   F   46 to 110   C    With LCD display     40 to 185   F   40 to 85   C   Process   At atmospheric pressures and above  See Table 4     1  LCD display may not be readable and LCD updates will be slower  at temperatures below  4   F   20   C      Pressure 9    Rosemount 3051    TABLE 4  3051 Process Temperature Limits    3051CD  3051CG  3051CA  Silicone Fill Sensor        40 to 250   F   40 to 121   C      with Coplanar Flange         40 to 300   F   40 to 149  C 2X9               with Traditional Flange  with Level Flange    40 to 300   F   40 to 149   C    with 305 Integral Manifold      40 to 300   F   40 to 149    C 2     Inert Fill Sensor  0 to 185   F   18 to 85  C   9     3051H  P
60. sia  110 3 bar      Range 4  6000 psia  413 7 bar   Rosemount 3051H     All Ranges  3626 psig  25 MPa   Rosemount 3051TG TA     Range 1  750 psi  51 7 bar      Range 2  1500 psi  103 4 bar      Range 3  1600 psi  110 3 bar      Range 4  6000 psi  413 7 bar      Range 5  15000 psi  1034 2 bar     For 3051L or Level Flange Option Codes FA  FB  FC  FD  FP  and  FQ  limit is O psia to the flange rating or sensor rating  whichever is  lower     TABLE 3  3051L and Level Flange Rating Limits    Standard Type CS Rating SST Rating  ANSI ASME Class 150 285 psig 275 psig  ANSI ASME Class 300 740 psig 720 psig  ANSI ASME Class 600 1480 psig 1440 psig    At 100   F  38   C   the rating decreases with  increasing temperature        DIN PN 10 40 40 bar 40 bar  DIN PN 10 16 16 bar 16 bar  DIN PN 25 40 40 bar 40 bar    At 248   F  120   C   the rating decreases  with increasing temperature     Rosemount 3051    Static Pressure Limit  Rosemount 3051CD Only    Operates within specifications between static line pressures of  0 5 psia and 3626 psig  4500 psig  310  3 bar  for  Option Code P9      Range 0  0 5 psia and 750 psig  3  4 bar and 51  7 bar   Range 1  0 5 psia and 2000 psig  3  4 bar and 137  9 bar     Burst Pressure Limits    Burst pressure on Coplanar  traditional  or 3051H process flange is  10000 psig  69 MPa      Burst pressure for the 3051T is  Ranges 1   4  11000 psi  75 8 MPa   Range 5  26000 psig  179 MPa     Failure Mode Alarm   Output Code A  If self diagnostics detect a gros
61. ssure Retaining        1  Span and Zero Adjustments are not available with fieldbus or profibus protocols        Pressure 17    Product Data Sheet  00813 0100 4001  Rev HA    Rosemount 3051 Catalog 2008   2009    3051C Coplanar Flange Dimensional Drawing     Differential Pressure Transmitter Shown              5 0  127  1 2 14 NPT Certification  4 3  110  Conduit Connection 4 1 Label  i  Two Places  Other  105   0 75  20  Clearance  _    me  20  paca Sizes Available    for Cover Removal      aaa echelon    Terminal    Transmitter M    Connections    Circuitry      a H                                                           ls 7 1  181   Nameplate           gt   8 2  209   Drain Vent Valve  N Housing Rotation  Set Screw  Coplanar Flange     y  Process Connection    I TY  Per IEC 61518  2 126  54  10 012 in  74 18 NPT on Coplanar Flange  6 4  163  Connection Centers for Pressure Connection without the Use       PA f Flange Adapt  112 14 NPT on Optional Flange Adapters  Adapters can be rotated Siege Adapters    to give connection centers of 2 00  51   2 126  54   or 2 25  57               Coplanar Flange Mounting Configurations with  Optional Bracket  B4  for 2 in  Pipe or Panel Mounting                                                                                                                                         5146 x 11 2 Bolts     for Panel Mounting  2 8  71  i   j   On  d  Not Supplied   z  Q  l  E Q    i  zZ  le 16 x 1 14 Bolts     amp    g for Mounting NN  E to 
62. t with SST Bolts H2 Traditional Flange 24  1 1     Same bracket as the B2 option with Series 300 stainless steel H3 Traditional Flange 2 7  1 2   bolts H4 Traditional Flange 2 6  1 2   B9 B3 Bracket with SST Bolts H7 Traditional Flange 2 5  1 1     Same bracket as the B3 option with Series 300 stainless steel FC Level Flange   3 in   150 10 8  4 9   bolts FD Level Flange   3 in   300 14 3  6 5   BA Stainless Steel B1 Bracket with SST Bolts FA Level Flange   2 in   150 10 7  4 8     B1 bracket in stainless steel with Series 300 stainless steel FB Level Flange   2 in   300 14 0  6 3   bolts FP DIN Level Flange  SST  DN 50  PN 40 8 3  3 8   BC Stainless Steel B3 Bracket with SST Bolts FQ DIN Level Flange  SST  DN 80  PN 40 13 7  6 2     B3 bracket in stainless steel with Series 300 stainless steel  bolts    Pressure 38    Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009 Rosemount 3051    3051C Differential Gage Pressure Transmitter Range Limits    Range 1 Span BEW  P AEST EU  Range 3 Span Range 4 Span Range 5 Span    min max min max min max min max min max       inH2O 0 5 25 2 5 250 10 1000 83 040 8304 553 60 55360  inHg 0 03678 1 8389 0 18389 18 389 0 73559 73 559 6 1081 610 81 40 720 4072 04  ftH20 0 04167 2 08333 0 20833 20 8333 0 83333 83 3333 6 9198 691 997 46 13 4613 31  mmH 0 12 7 635 5 63 553 6355 254 25421 2110 95 211095 14073 1407301  mmHg 0 93416 46 7082 4 67082 467 082 18 6833 1868 33 155 145 15514 5 1034 3 103430  psi 0 01806 0 903 0 0902 9 03183 0 3
63. ta Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009 Rosemount 3051    TABLE 12  3051T Gage and Absolute Pressure Transmitter  Model Transmitter Type    3051T Pressure Transmitter  Code Pressure Type          G Gage  A Absolute  Code Pressure Ranges  Range Min  Span   3051TG    3051TA  1    14 7 to 30 psi 0 3 psi   1 01 to 2 1 bar 20 7 mbar  0 to 30 psia 0 3 psia  0 to 2 1 bar 20 7 mbar   2    14 7 to 150 psi 1 5 psi   1 01 to 10 3 bar 103 4 mbar  0 to 150 psia 1 5 psia  0 to 10 3 bar 103 4 mbar   3    14 7 to 800 psi 8 psi     1 01 to 55 2 bar 0 55 bar  0 to 800 psia 8 psia  0 to 55 2 bar 0 55 bar   4    14 7 to 4000 psi 40 psi     1 01 to 275 8 bar 2 8 bar  0 to 4000 psia 40 psia  0 to 275 8 bar 2 8 bar   5    14 7 to 10000 psi 2000 psi     1 01 to 689 5 bar 138 bar  0 to 10000 psia 2000 psia  0 to 689 5 bar 138 bar     Code Output   A 4   20 mA with Digital Signal Based on HART Protocol   M Low Power 1   5 V dc with Digital Signal Based on HART Protocol  See Option Code C2 for 0 8   3 2 V dc Output     Not available with hazardous certification Option Codes I1  N1  E4  K6 or K8    F FOUNDATION fieldbus Protocol   Ww Profibus     PA  Code Process Connection Style   2B  2 14 NPT Female   2C G  A DIN 16288 Male  Available in SST for Range 1   4 only   2F Coned and Threaded  Compatible with Autoclave Type F 250 C  Only available in SST for Range 5   Code Isolating Diaphragm Process Connection Wetted Parts Material   2 316L SST 316L SST   30   Hastelloy C276 Hastelloy C276  C
64. the equipment shall be of a type  which requires the use of a tool to effect its removal  Voltage  source shall not exceed 55V dc     Combinations of Certifications   Stainless steel certification tag is provided when optional approval  is specified  Once a device labeled with multiple approval types is  installed  it should not be reinstalled using any other approval  types  Permanently mark the approval label to distinguish it from  unused approval types     K5 E5 and 15 combination   KB K5 and C6 combination   KD K5  C6  11  and E8 combination  K6  C6 11  and E8 combination   K8 E8 and 11 combination   K7  ET I7  and N7 combination    Pressure 14    Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009    Product Data Sheet  00813 0100 4001  Rev HA  Catalog 2008   2009    FIELDBUS PROTOCOL    Hazardous Locations Certifications    North American Certifications IA  FM Approvals  E5  Explosion Proof for Class I  Division 1  Groups B  C  and D     Dust Ignition Proof for Class II  Division 1  Groups E  F  and  G  Dust Ignition Proof for Class III  Division 1     Intrinsically Safe for use in Class I  Division 1  Groups A  B   C  and D  Class II  Division 1  Groups E  F  and G  Class lll   Division 1 when connected per Rosemount drawing  03031 1019  Non incendive for Class I  Division 2  Groups  A  B  C  and D     Temperature Code T4  Ta   60   C   T3  Ta   85   C    Enclosure Type 4X  For input parameters see control drawing 03031 1019     Canadian Standards Associa
65. tion  CSA     E6    C6    Explosion Proof for Class I  Division 1  Groups B  C  and D  N1  Dust Ignition Proof for Class II and Class III  Division 1    Groups E  F  and G  Suitable for Class I  Division 2 Groups   A  B  C  and D for indoor and outdoor hazardous locations    Enclosure type 4X  factory sealed    Explosion Proof and intrinsically safe approval  Intrinsically   safe for Class I  Division 1  Groups A  B  C  and D when   connected in accordance with Rosemount drawings   03031 1024  Temperature Code T3C    Explosion Proof for Class I  Division 1  Groups B  C  and D   Dust Ignition Proof for Class II and Class III  Division 1    Groups E  F  and G  Suitable for Class    Division 2 Groups E8  A  B  C  and D hazardous locations  Enclosure type 4X    factory sealed   For input parameters see control drawing 03031 1024     European Certifications    n    ATEX Intrinsic Safety and Dust   Certification No   BAS 98ATEX1355X     II 1 GD  EEx ia IIC T4  Tamb      60 to  60   C    Dust Rating  T70   C  Tamb    20 to 40   C  IP66   ce 1180    TABLE 7  Input Parameters    U    30V       300 mA  Pj213W  C    0 uF    Special Conditions for Safe Use  X     The device is not capable of withstanding the 500V  insulation test required by Clause 6 4 12 of EN50020 1994   This must be taken into account when installing the  apparatus     Rosemount 3051    ATEX FISCO Intrinsic Safety   Certification No   BAS 98ATEX1355X      II 1 G  EEx ia IIC T4  Tamp      60 to  60   C    IP66   ce 118
66. tions cD fore  coy   Q4 Calibration Data Sheet        Q8 Material Traceability Certification per EN 10204 3 1 B  Only available for the sensor module housing and   d l    Coplanar or traditional flanges and adapters  3051C   and for the sensor module housing and low volume  Coplanar flange and adapter  3051C with Option Code S1      Q16 Surface finish certification for sanitary remote seals        QZ Remote Seal System Performance Calculation Report     d  QP Calibration certification and tamper evident seal s   ig  QS Certificate of FMEDA Data s      J18  Local Zero Adjustment Only     3  J308  No Local Zero or Span Adjustment Y Y E  T1 Transient Protection Terminal Block        c1   Custom Software Configuration  Completed CDS 00806 0100 4001 required with order         C2U  0 8 3 2 V dc Output with Digital Signal Based on HART Protocol  Output Code M only         C3 Gage Calibration  3051CA4 only             C4UX9  Analog Output Levels Compliant with NAMUR Recommendation NE 43        CN  Analog Output Levels Compliant with NAMUR Recommendation NE 43 Alarm Configuration Low        P1 Hydrostatic Testing with Certificate        P2 Cleaning for Special Service        P3 Cleaning for  lt 1 PPM Chlorine Fluorine        P4 Calibrate at line pressure  Specify Q48 on order for corresponding certificate  E E    DF 1 2  14 NPT flange adapter s     Material determined by flange material   7    D7 Coplanar Flange Without Drain Vent Ports        D8 Ceramic Ball Drain Vents        D9 JI
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
壁掛けユニット 取扱説明書  Installation, operation & service manual AlarmScout A15  Tucano Leggero  User-Manual - Newegg.com  TouchSystems V463I6BOL Point Of Sale terminal  Mitel Speech Server User's Manual  FastPack Products FP-DFLEX-10K Customizable FLEX10K I/O    APC BACK-UPS RS 1000 User's Manual      Copyright © All rights reserved. 