1.     The ragulator starts operating as the furnace door closes  opening sensor of the door   supervises the  combustion process  temperature sensor of combustion  air choke valve   shuts off air supply as  there s the embers phase in the furnace  Additionally the regulator can increase the chimney draught  in the heating phase  flap drive of the by pass of the heat accumulation module     In emergency situations  power decrease as well  the choke valve opens  enabling a full burn out of  the fuel  The special input for connecting any external control device of CO concentration increases  the safety ofa fireplace user    The regulator is equipped with its own emergency power supply  The pause in power supply up  to 8secs doesn t affect regulator operation because during that time the buffer power supply  switches on  If the pause is longer the choke valve opens up in emergency and then the regulator  switches off     Advantages of the combustion optimizer     lowering the maximum combustion temperature    extending the combustion process    decreasing fuel consumption    extending the exploitation time of fireplace inputs    shutting off air supply after ending the combustion  preventing the furnace cool off    optimal use of the heat accumulation module    cooperation with CO sensors  opening up the fresh airing in emergency     The regulator can control a fireplace without the opening sensor of the door  In that case the  buttons on the front panel are used         CHIMNEY   
2.   PARAMETERS OF LEVEL 3    3 Service of the regulator   There are elements on the control panel  Fig  2   In the standby state only the green diode  7  lights  indicating the standby mode  The turn on of the regulator follows after opening the furnace door   After closing the door the combustion cycle starts  which is signaled by the green diode  8       CHOOSE           CONFIRM     Fig 2 Control panel view    Text display   Increase button          or START    Choice button of parameter   Decrease button         or STOP    Confirm button  or AUTO    Manual operation button    MAN      Status LED diode of the regulator  emergency red   standby  green   LED diode of combustion cycle  the green one    LED diode of choke valve operation  blinking means the overload of the drive        4       e ON a tS    WARRANTY    1 Warranty is valid  24  months from the date of sale    2 Producer does not take responsibility for any mechanical damages made by user   3 MAKING REPAIRS OR MODYFYING THE DEVICE BY USER IS   FORBIDDEN AND CAUSES WARRANTY CANCELATION   4 Warranty card is valid only with date of sale  seller s signature and stamp  5 Warranty and after warranty repairs should be done only by producer  damaged  regulators should be sent to producer in order to make all repairs needed   6 Warranty protection involves the EU   7 Warranty does not exclude  not restrict and not suspend buyer   s rights coming from  the incompatibility of the article with the agreement  Laws Journal No  14
3.   The choke valve first opens up and then  closes and there s the pass to the standby phase     20 ON    2 2 Air choke valve  The choke valve regulates air inflow to the combustion chamber dependent on the phase    During the flap move of the choke valve the diode  9  lights  The blinking means a temporary  overload of the drive affected by met resistances   2 3 Restricting the maximum temperature of the combustion  Exceeding the temperature defined by the parameter  T max  causes closing the air choke valve  within the range of 10    50   Parameter  ChokeVTH    and the alarm turns on  The closing  process begins with 50  C before reaching this limit  Cancelling the alarm and the return to the  standard operation of the air choke valve occur ifthe temperature falls to T max   50  C   2 4 Programs Variants of the operation of the regulator  The basic function of the regulator is to optimize the combustion process by controlling the air choke  valve  The regulator can control a distribution of produced heat in the following variants  Fig 3  presents the right operation diagrams    Program 1    MAC      1  During the normal operation heated exhaust gases pass through the heat accumulation  module  MAC   where they give back heat  cooling off   During the heating up when the fireplace is cold   its draught can be insufficient  The regulator sets  the flap    K1   in the position of bypassing the MAC and directs the exhaust gases into the chimney   After reaching the preset temper
4.  FIREPLACE    PP    Fig 1 Basic operation scheme of the regulator    Tl Temperature sensor of the combustion  D1 Opening sensor of the furnace door  option   PP Controlled air choke valve     n       Admission  date    Realization  date    Signature    Remarks                                                                                           NT TT ay Q  C 4  ISO 9001  2000  CE CONFORMITY DECLARATION    Ref  No  58 RT 01 2007 1 B    We  ZAK  AD ELEKTRONICZNY TATAREK Jerzy Tatarek  75 Swieradowska St    50 559 Wroclaw    declare under our sole responsibility that  the product  Regulator of heating system with solar collector    model  RT 08  RT 08K  RT 08P  RT 080s    is in conformity with the basic requirements included in Directive EMC 2004 108 WE of 15 12 2004  the  electromagnetic compatibility law of 13 04 07  and Directive LVD 2006 95 WE of 21 08 07  Laws Journal  of 2007 No  155 pos  1098  regarding the requirements for electric devices     To the conformity evaluation the following harmonized standards were used     PN EN 60730 2 1  2002   Automatic electric regulators for house usage and the like  Part 2 1   Specific requirements regarding electric regulators for electric house  devices   Automatic electric regulators for house usage and the like    Part 1  General requirements     PN EN 60730 1  2002      PN EN 55022  2000   Electromagnetic compatibility  EHMC   IT devices  Characteristics of radioelectric noises  Acceptable levels and measurement methods    Co
5.  HA 1200    lt    _ Combustion temp   T1  Possibly blinking   END     F1 50   Demand for replenishing the fuel     Level of choke valve opening    Phase of operation    Reaching the embers phase F7 is accompanied by a broken sound signal  switch off with the button   6     text    FuelOUT       and blinking of the green diode  8   which indicates the need for replenishing  the fuel in case of continuing the heating    The regulator can run in the automatic or manual mode  The longer pressing    MAN     6  about 2secs  causes the pass to the manual mode  That s signalled by blinking status diode  7   The choke valve  opens 100   From now on you can manually control the choke valve          4  causes the shutting  one  step 10   and         2  the opening  The comeback to the automatic mode occurs after pressing     AUTO     5     In the automatic mode each opening of the door causes the choke valve to be set at 100  and each  shutting of the door causes the combustion process started and the diode  8  lights    If the furnace is cold then after the time    DelayTim Ti STOP     see parameters of level 2  the  regulator closes the choke valve and passes to the standby state    Likewise the regualtor acts when the power turns on           During the operation without the opening sensor of the door the panel buttons are used for  controlling  Pressing    START     2  causes opening the choke valve and starting the cycle  Before  opening the door the choke valve should also be open
6.  Parameters of level 3 were chosen      CHOOSE    button   gt     TFlapOFF    shows up actual value      CONFIRM    button   gt  actual value to be changed begins blinking     7        gt  setting a new value     CONFIRM      gt  confirming the new value    repeatedly    CHOOSE    button till the          parameter end setting screen appears                                                           PARAMETERS OF LEVEL 4  NAME RANGE FACTORY SETTING FUNCTION  SETTING   NoProd 0   n 0 Number of the parameters set dependent on the  fireplace producer  PARAMETERS READONLY   Password 0   20 0 0 PASSWORD DEACTIVATED  1   20 PASSWORD ACTIVATED   Reset  1   0   n 0 Setting the value  n   0  n  calls back all the factory  settings linked to the  n th  parameters set and  causes the restart of the regulator   PARAMETER ONLY AVAILABLE WITH  THE ACTIVATED PASSWORD  Password    The changes of important parameters are possible only at unlocked password  To unlock thepassword you need to input proper sequence of  digits with the buttons           With the CHOOSE button  3  to change the digits position and CONFIRM button  5  to acknowledge all   and finish the procedure of changing the password  The unlocked password is set to    0000       Once again entering into the password change procedure causes a new password to be set     PASSWORD   9999    HAS CONSIDERABLE MEANING  IT CAUSES THE REACTIVATION OF THE PREVIOUS PASSWORD IF  PRESENT WITHOUT IT BEING EXPOSED      PASSWORD OF PRODUCER S SE
7.  The operation state is presented on the text display  1   The screens inform about the operation of  devices  temperature of the furnace  they make it possible to change the parameters etc   The change  of screen is done by pressing the CHOOSE button  3   If this is a screen that is able to change a  parameter  press the CONFIRM button 5   which causes blinking of the parameter field to be  changed  By pressing          2  or          4  one can alter its value    By clicking the CONFIRM button  5  one confirms the changes   the parameter field stops blinking   The changed parameter not confirmed for 10 secs is not accepted by the regulator and it recalls a  previous value of the parameter     3 1 Screens  Alarm screens is not seen till the following emergency situation takes place   1  Damage of the sensor T1      T Firep    shows up   2  Damage of the internal sensor of the reference temperature     Ref Temp    shows up   3  Exceeding of the limit concentration of CO by short circuiting the contacts X1      Gas    shows up        Emergency situation is accompanied both by a broken sound alarm that can be turned off by  pressing any button and a blinking of the red diode 7      Screen of the regulator operation shows actual temperature of fireplace  level of choke valve  opening  phase of operation and possibly combustion error     HA  By pass flap is turned on  program    MAC         WA  Activated flap that directs the heat into the water attachment program   W ATER       
8.  by pressing    START    2  or passing to the  MAN mode  After lighting the fuel and closing the door you must again press    START     2  or     AUTO    5  ifthe regulator is in the manual mode    MAN          In the MAN mode you must not close the choke valve completely before reaching the embers  phase because there can be a dangerously increased concentration of CO  poisonous carbon  monoxide       The screen of the water circuit  for the program    WATER    and    MIX     shows actual  temperature of the water attachment and the buffer  operation of the pump and the water attachment  flap           lt        Water temperature in the buffer  T3          Water temperature in the attachment  T2   The arrows before the temperatures show the heat flow    The arrow before T2 indicates the switch on of the flap that directs warm exhaust gases into the  water attachment  the attachment is feeded by heat      The arrow between T2 and T3 indicates the switch on of the pump that receives the heat from  the attachment and directs it to the buffer     Screen of setting the parameters       Menu  0    Normally the level of parameter setting  Menu  equals to    0     which means the parameters aren   t  available    After changing the level to    1        2      or  3  the successive screens show the values of  parameters    The last screen contains            after which it comes back to the above mentioned screens       PARAMETERS ADAPT THE REGULATOR TO THE PROPERTIES OF THE  FIREPLA
9.  the water attachment   Program 2  WATER    T2FlapON 20   100  C 70   C Water temperature in the attachment that turns  on the flap  directing exhaust gases through the water  attachment  The lower temperature activates  the water attachment   Program 2  WATER    T2FlapOF 20   100  C 85  C  Water temperature in the attachment that turns  off the flap   Exhaust gases don t pass through the wate  lattachment  The higher temperature deactivates  the water attachment   Program 2  WATER    T2PmpON 20   100  C 55   C Above this water temperature in the  attachment the pump feeding the buffer  turns on  Program 2  amp  3  WATER  amp  MIX    T2PmpOFF 20   100  C 50  C Below this water temperature in the  attachment the pump feeding the buffer  turns off  Program 2  amp  3  WATER  amp  MIX    dT2 T3 1   20  C oe Difference of water temperature between  the attachment and the buffer that activates  the feeding pump  Program 2  WATER    T2 MAX 80   99  C 95  C Water temperature in the attachment that switches on      m _  the alarm  Program 2  amp  3  WATER   amp  MIX                                    Demonstration change of the    TFlapOFF    parameter that defines the temperature at which  the flap of the MAC by pass  parameter of level 3  switches over   Press         press CHOOSE till the    ServNo 0    parameter setting screen appears     CONFIRM    button  gt    0    starts blinking    threefold button           gt    3    blinks     CONFIRM    button   gt    3    stops blinking 
10. 1 Pos  1176     WARNING     ANY MODIFICATION OF THE REGULATOR MADE BY USER CAN BE  THE CAUSE OF SAFETY CONDITIONS DETERIORATION AND CAN  EXPOSE THE USER TO ELECTRIC SHOCK OR DAMAGE DEVICES  SUPPLIED     Connection cable of regulator may be replaced only  by producer or his authorized service locations    WARNING   1  Producer does not take the responsibility for damage    caused by atmospheric discharge  2  and overvoltage in the mains  3  Burnt fuses are not subject to warranty replacement       Date of sale Seller s signature and stamp    ARGO FILM  Recycling Plant No  6  180 Krakowska st   52 015 Wroclaw    Register No   GIOS  E 0002240WZ    Worn out electronic    the utilization collection place  where will 0 515 122 142    be accepted for free       and electric devices must be transfered to Ph   071 794 43 01  T    ew E   INNTASS  a   Zak  ad elektroniczny TATAREK Jerzy Tatarek  50 559 Wroclaw  75 Swieradowska st  ph   071  367 21 67  373 14 88  fax 373 14 58  tax index number 899 020 21 48   Bank account   BZ WBK S A  O WROCLAW 6910901522 0000 0000 5201 9335  www tatarek com pl   E mail  tatarek tatarek com pl       RTO80s    Combustion curve with the marked parameters of the control    choke valve       ChokeVF4         my  Wee NEL     wane          ChokeVF5 E TT    wane    nenae     Senay  dl Tee  S   runan   aR       ChokeVF7    Temp  rc           T F5                v                    T F7max            a Ae eaan       o  gt  Time  Ti F7  min     EA  5e  N  AE   
11. CE  THEIR CHANGE SHOULD BE CONSULTED WITH THE PRODUCER  OF THE FIREPLACE  INCAUTIOUS CHANGES CAN CAUSE UNSTABLE AND  INEFFICIENT OPERATION OF THE SYSTEM              PARAMETRS OF LEVEL 1       FACTORY  SETTING    Signal OFF ON ON    NAME RANGE SETTING FUNCTION             Switch on Switch off of the sound alarms                                                       WATER i       L       CHIMNEY    HEAT  ACCUMULATION  MODULE        FIREPLACE             PP  choke valve                   SENSOR             T2          ALARM white    GREEN  T1 Alarm CO    P1  230V 50Hz    PE N L    MAINS  230V 50Hz    Fig 3C System scheme in the version of program 3   MIX       PP   X3     D1     T1     T2   P1     Electronically controlled air choke valve   Input to connect a control device of CO concentration  The input         has higher potential  it s important for  Open Collector Systems   Schort circuit of the contacts means the exceeding of permitted CO concentration   At the lack of CO control you leave the contacts not connected    Opening sensor of the furnace door  The type of the sensor is defined by the parameter  DoorMode     Short circuit sensor applied  at the door closed the contact D1 shorted   set  DoorMode  2    Open circuit sensor applied  at the door closed the contact D1 opened   set  DoorMode      Without the door sensor leave the contact D1 unconnected and set  DoorMode  1 or   short the contact D1 and set  DoorMode  2   Sensor of combustion temperature  Thermocouple ty
12. RVICE IS UNIQUE AND IS NOT DEPENDENT ON THE USER S PASSWORD  IT SHOUDN T BE  EXPOSED TO THE USER  INSTEAD OF THAT THE SERVICE CAN SET THE USER HIS OWN PASSWORD     Examples of passwords    1 The control unit is installed with the unlocked password  The user can enter his own password e g     1234     From this  moment the important parameters cannot be altered without the password being unlocked  that is  resetting the password  1234      After changing essential parameters the user can leave the controller unlocked  set any new password or enter     9999     which activates the password    1234      2  Producer gives the controller with the set password  The user cannot alter the important parameters    The servic can change the settings with its own secret password  At the end a serviceman enter the secret password or     9999     the user still hasn t access to the important parameters    3  Producer gives the controller with the set password  The user cannot alter the important parameters    The servic can change the settings with its own secret password  At the end a serviceman leaves the controller unlocked  the  user now has access to the important parameters  He can enter his own password like in example No  1    4  Producer gives the controller with the set password  The user cannot alter the important parameters  The servic can  change the settings with its own secret password At the end a serviceman sets the password e g     1234    and tells it to the  user  the u
13. WANASSX  Zak  ad elektroniczny TATAREK Jerzy Tatarek    50 559 Wroclaw  75 Swieradowska st   ph   071  367 21 67  373 14 88  fax 373 14 58  Tax index number 899 020 21 48   Bank account  BZ WBK S A  WROCLAW 6910901522 0000 0000 5201 9335  www tatarek com pl   E mail  tatarek tatarek com pl    6             WANA    RT080s 2015 v3 5 ANG TITANIUM    Zak  ad elektroniczny TATAREK Jerzy Tatarek       USER MANUAL    v 3 5  02 02 2015 program version from 3 5     FIREPLACE OS COMBUSTION OPTIMIZER  RT 080s TITANIUM       1 Basic technical parameters    Power   Auxiliary power source   Power consumption without load  Maximum connection power    Operation conditions    Housing protection class   Fuse   Number of outputs to control the flap drive  Number of nonvoltage control outputs   Number of outputs to control the choke valve drive  Number of temperature sensors   Temp  measurement precision    Temp  measurement resolution    Jotul Group  Accessories    230V 50Hz  Rechargeable battery 4 8V 60mA  5W  250W  0 40  C  humidity 10 90    no condensation   IP41  6 3A 250V  1   250W 230V 50Hz  1   NO and NC contacts  1   5V 500mA DC  1   Thermocouple type K 0    1300  C    5  C  1  C    2  Principle of operation    With the air choke valve the regulator controls the combustion process and maintains the embers  phase    By lowering the combustion curve in the phase of increasing temperature and by raising it in the  phase of decreasing temperature the regulator extends the combustion process
14. ature  chimney is heated up  tha flap position is changed and the  exhaust gases are directed into the MAC   2  To the regulator you can connect an external control device of CO concentration  In  emergency the choke valve opens up improving a room ventilation  additionally the alarm switches  on    3  The regulator turns on the output ALARM in case of damage of the temperature sensor of the  furnace  T1  or exceeding the limit concentration of CO2     Program 2    WATER      1  The fireplace is equipped with the water attachment  If water temperature in the  attachment reaches the preset value  sensor T2  and is higher than the buffer temperature  T3   then the pump    P1      which loads the buffer  switches on    2  The controlled flap    K1    directs warm exhaust gases into the water attachment when   there s a demand for warm water     PROGRAM 3  MIX      1  The fireplace is equipped with the water attachment  If water temperature in the  attachment reaches the preset value  sensor T2  then the pump    P1      which receives heat  it loads the  buffer   switches on    2  To the regulator you can connect an external control device of CO concentration  In  emergency the choke valve opens up improving a room ventilation  additionally the alarm  switches on    3  The regulator turns on the output ALARM in case of damage of the temperature sensor of the  furnace  T1  or exceeding the limit concentration of CO2       CHOICE OF THE PROGRAM AND ITS SETTINGS ARE AVAILABLE IN THE
15. d burning out exhaust gases  ChokeVF4 0   100   70  Level of choke valve opening at the start of F4  ChokeVF5 0   100   50  Level of choke valve opening at the start of F5  Choke VF7 0   100   5  Level of choke valve opening at the start of F7  TypChoke 1 2 1 Control type of the choke valve  1  Continuous control   servomotor of the  choke valve always active  2 Dynamic control   servomotor of the choke valve  active only if a position change of the choke valve   is needed   T max 400   1300   C 800   C Maximum temperature of the fireplace  ChokeVTH_   10   50  30  Opening level of the choke valve after exceeding  T max  DoorMode te 1 T p ree door closed the contact DI open   or no door sensor  2  short circuit sensor  at the door closed the contact DI shorted  PARAMETERS OF LEVEL 3  THE PARAMETERS CAN BE ALTERED BY DEACTIVATED PASSWORD  NAME RANGE ete   SETTING FUNCTION  SE i  Program 1 3 3 1 PROGRAM _  1     MAC    Fig  3A  2    WATER    Fig  3B  3   MEX    Fig  3C  TFlapOft 200   1000  C 700  C    Combustion temperature that closes the bypass flap   Activation of the module MAC  Program 1  MAC    T1FlapON 200   1000  C 440   C  Combustion temperature that turns on the flap   directing exhaust gases through the water  attachment  The higher temperature activates  the water attachment   Program 2  WATER    T1FlapOF 200   1000  C 370   C Combustion temperature that turns off the flap    Exhaust gases don t pass through the water  attachment  The lower temperature deactivates 
16. from the water attachment   Flap drive of the by pass of the heat accumulation module  option              PARAMETERS OF LEVEL 2  THE PARAMETERS CAN BE ALTERED BY DEACTIVATED PASSWORD       FACTORY                                                                                                                                                                                                    NAME RANGE SETTING SETTING FUNCTION  DelayTim 15   600secs 60secs Delay of regulation start  period of the phase F1   T Restar 10   51250  C 45  C Restart temperature after switching on   tii If after switching on the regulator temperature  in the furnace is higher than  T Restar  then  automatic start follows   Ti STOP 0   600secs 120secs After this time the transition to the standby phase   STOP  takes place if the temperature  T Restar   is not reached   T F3 30   1250  C 120  C start temperature of the phase F3  T F4 50   1250  C 270  C start temperature of the phase F4  T F5 50   1250  C 370  C start temperature of the phase F5  dT F5  F6  10    300  C  30  C Temperature drop in relation to the maximum  temperature  start of the phase F6   T F7max 50   1250  C 220  C start temperature of the phase F7  T F7min 50   1250  C 120  C start temperature of the phase F7 in case  the maximum temperature is reached in F3  or F4  There wasn t the phase F5   Ti F7 1   60 mins 20 mins Period of the phase F7  Ti PDM 0   10 mins 1 mins Period of the phase F8  Scavenge time Opening the  choke valve an
17. mplementary information   Laboratory  ASE 51 618 Wroclaw  1 Wystawowa st     Test report No  39 DL I 07 of 22 06 2007  41 DL 1 07 of 03 07 2007    Electronic Engineering Plant TATAREK  has initiated management system and complies with the following standard    ISO9001  2000 CERTIFICATE No  133 2004 of 01 2004  Polish Foreign Trade Chamber    The last two digits of the year in which the CE marking was affixed  07    Place of issue  Manufacturer representative     Wroclaw Miros  aw Zasepa  Lasgo  Date of issue  Position   08 2007 Konstruktor    2 1 Operation phases of the regulator  The regulator controls the combustion process as a cycle of the following phases    1  FO STOP   Standby phase  The regulator awaits opening the door and preparing the fuel  for the next heating  FO is a temporary state to STOP  In the STOP state the choke valve  is closed    2  Fl   Start phase  After loading the fuel and its lighting you close the furnace door  It s a  signal for the regulator that the combustion cycle has begun  The choke valve is fully  open    3  F2   Heating up phase  After reaching the limit temperature the pass to the phase F3   follows    F3  F4   Phase of increasing temperature  The choke valve is gradually closed    F5   Burning phase  Awaiting the maximum temperature of the process   F6   Phase of decreasing temperature  The choke valve is again gradually closed  F7   Embers phase  Signalling the demand for replenishing the fuel   F8   Phase of removing the exhaust gases
18. ms   Schort circuit of the contacts means the exceeding of permitted CO concentration  At  the lack of CO control you leave the contacts not connected    D1 Opening sensor of the furnace door  The type of the sensor is defined by the parameter  DoorMode     Short circuit sensor applied  at the door closed the contact D1 shorted   set  DoorMode  2   Open circuit sensor applied  at the door closed the contact D1 opened   set  DoorMode     Without the door sensor leave the contact D1 unconnected and set  DoorMode  1 or  short the contact D1 and set  DoorMode  2    Tl Sensor of combustion temperature  Thermocouple type K  the wire of higher potential is green  of lower one is  white   K1 Flap drive of the by pass of the heat accumulation module  option     
19. pe K  the wire of higher potential is green  of lower one is  white    Temperature sensor in the water attachment   Pump receiving the heat from the water attachment                      CHIMNEY       HEAT  ACCUMULATION  MODULE       FIREPLACE                         ee  Dib ooR                   SENSOR  T2  oH ae A  Hi WHITE    GREEN  PE    T3  eo T1  P1 i K1  230V 50Hz t   230V 50Hz  be N L  MAINS  230V 50Hz    Fig 3B System scheme in the version of program 2   WATER       PP  XI    D1    Tl    T2  T3  P1  K1    Electronically controlled air choke valve   Input to connect a control device of CO concentration  The input         has higher potential  it s important for  Open Collector Systems   Schort circuit of the contacts means the exceeding of permitted CO concentration   At the lack of CO control you leave the contacts not connected    Opening sensor of the furnace door  The type of the sensor is defined by the parameter  DoorMode     Short circuit sensor applied  at the door closed the contact D1 shorted   set  DoorMode  2    Open circuit sensor applied  at the door closed the contact D1 opened   set  DoorMode  1    Without the door sensor leave the contact D1 unconnected and set  DoorMode  1 or   short the contact D1 and set  DoorMode  2   Sensor of combustion temperature  Thermocouple type K  the wire of higher potential is green  of lower one is  white    Temperature sensor in the water attachment   Temperature sensor of the buffer  option    Pump receiving the heat 
20. ser has access to the important parameters but without knowing the password the other persons cannot make the  changes    5  The user has the unlocked controller or his own password  Serviceman decides  the user though oughtn t have access to  the important parameters  The serviceman locks the control unit with his secret password  which removes the user s  password and locks the controller    6  Serviceman doesn t have to know the user s password  Always he can use his own secret password and at the end lock  with the    9999     which reactivates the user s password      8             nang the regulator  THE REGULATOR IS SUPPLIED BY 230V 50HZ   ANY MOVES REGARDING INSTALLATION  SHOULD BE MADE ATTHE DISCONNECTED MAINS      THE REGULATOR HAS TO BE CONNECTED TO THE MAINS WITH THE ZERO PIN      THE REGULATOR SHOULD NOT BE EXPOSED TO WATER AFFECTING  ITS ENVIRONS OUGHT  TO BE CLEAN      THE PRODUCER DOESN T TAKE ANY RESPONSIBILITY FOR DAMAGES CAUSED BY WRONG  USAGE OF THE REGULATOR         CHIMNEY         HEAT  ACCUMULATION  MODULE       PP  choke valve  vcc RED    STER YELLOW BLUE   GND BLACK                                            e  D  DOOR   gt    SENSOR     ALARM wane    GREEN X3  T1 Alarm CO  K1 L MAINS  230V 50Hz nN 230V 50Hz  Fig 3A System scheme in the version of program 1    MAC     PP Electronically controlled air choke valve  X3 Input to connect a control device of CO concentration  The input         has higher potential  it s important for    Open Collector Syste
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
EFR Bedienungsanleitung Home Display  téléchargez le dans son intégralité [ PDF - 28p - 3.62 Mo ] - Athis-Mons  Télécharger - Conseil Régional de Franche  2002 Dimension One Spas Owner Manual  Axxon Smart Software-Paket  Magic Cappuccino SIN 017  Samsung SP-L331 Felhasználói kézikönyv  WiPro „all in one“ DE GB FR NL IT DK SE  Integrator/IM-PD1 User Guide  Wells H-115 User's Manual    Copyright © All rights reserved. 