Home

User Manual - DAVI Y CIA, S.L.

image

Contents

1. 4 Slide the right piece of the height rod until it touches the baby s feet 5 Takereading from Picture A 17 USER S MANUAL MA13 02 B 6 Pulloutto use 7 Remove baby 7 6 TROUBLESHOOTING If feet piece is loose please re assemble feet piece as below NOTE Ifthe reading has error please follow RESET procedure for calibration 7 7 TECHNICAL SPECIFICATIONS Model AC2080D AC2080M Scale mounted height rod Hold Reset Unit Measurement range 35 80cm Dimensions WKH x L297 62cm o Power Supply 2 AAArsizebatteries 10 C up to 40 C 18 USER S MANUAL MA13 02 B 8 TECHNICAL SPECIFICATIONS BS1015C 15 kgx2g lt 6 kg gt 5g Display LCD display with 5 and 1 2 digits Digit size 24mm Tray dimensions 550 x 290 mm Power supply AC adapter 15V 300mA Rechargeable Battery Key Functions ON OFF ZERO PRINT BMI HOLD PRE TARE TARE CLEAR ENTER 0 9 M1 5 Operation temperature 5 C 35 C 19 USER S MANUAL MA13 02 B 9 WARRANTY CERTIFICATE We provide a 1 year guarantee from the date of purchase The guarantee covers manufacturing defects or defects occurring as a result of normal use and operation It excludes all removable parts such as batteries wires power supply devices etc Faults falling within the guarantee period shall be rectified free of charge upon presentation of the purchase receipt for the appliance No other rights can be taken into consideration
2. Return shipment is at the customer s expense if the appliance is anywhere other than at the customer s headquarters In the event of damage during shipment guarantee rights will be granted only if the appliance is shipped in the original packaging You are therefore recommended to keep the original packaging Following expiry of the guarantee period all services requested will be dealt with by our specialist technicians at the user s expense 20 USER S MANUAL MA13 02 B 10 CE DECLARATION OF CONFORMITY CE DECLARATION OF CONFORMITY FABRICANTE PRODUCTO DAVI amp CIA S L PRODUCT MANUFACTURER DIRECCI N C Murcia 35 Nave G ADDRESS Pol gono Industrial Can Calder n E08830 Sant Boi de Llobregat BARCELONA ESPA A DECLARAN BAJO SU RESPONSABILIDAD QUE EL PRODUCTO DECLARE UNDER THEIR RESPONSIBILITY THAT THE PRODUCT Marca DAVI 8 CIA Brand Nombre BS1015C Name Tipo EQUIPO ELECTRONICO Type Electronic equipment Finalidad Prevista Equipo pesapersonas Intended Use Weighing equipment CUMPLE LOS REQUISITOS DE LAS DIRECTIVAS CONFORMS WITH THE REQUISITES OF THE DIRECTIVES EC Directive 2004 108 EC Directiva de Compatibilidad Electromagn tica Electromagnetic Compatibility Directive EC Directive 2006 95 EC Directiva de Baja tensi n Low Voltaje Directive EC Directive 93 42 EEC Aplicable nicamente a las b sculas con aprobaci n m dica Applies only to scales with medical approval FECHA 12 de Diciembr
3. BS1015C USER S MANUAL MA13 02 B 12 09 2011 DAVI amp CIA www davicia com USER S MANUAL MA13 02 B INDEX 8 9 DESCRIPTION INSTALLATION 2 1 Scale assembly 2 2 Location and setting 2 3 Startup OPERATION 3 1 LCD symbol description 3 2 Key functions 3 3 Weighing 3 4 Taring 3 5 Hold SETUP 4 1 Connecting with PC MAINTENANCE AND CLEANING 5 1 Instructions for charge and connect 5 2 Instructions for replacing batteries 5 3 Environmental 5 4 Equipment disposal TROUBLESHOOTING HEIGHT ROD ACCESSORIES 7 1 Height rod assembly 7 2 Battery installation 7 3 Key functions 7 4 Calibrating the height rod 7 5 Using the height rod 7 6 Troubleshooting 7 7 Specifications TECHNICAL SPECIFICATIONS WARRANTY CERTIFICATE 10 CE DECLARATION OF CONFORMITY Page NAB A oO 00 00 00 N N 10 12 12 12 12 12 13 14 14 15 15 16 16 18 18 19 20 21 D USER S MANUAL MA13 02 B 1 DESCRIPTION 1 Display unit 2 Display mounting column 3 Tray 4 Scale platform 5 Adjustable feet USER S MANUAL MA13 02 B 2 INSTALLATION Before putting the device into use please read with care the information given in the Operating Instructions They contain important instructions for installation proper use and maintenance of the device The manufacturer shall not be liable for damages arising out of failure to heed the following instructions
4. o When using electrical components under increased safety requirements always comply with the appropriate regulations Improper installation will render the warranty null and void Ensure the voltage marked on the power supply unit matches your main power supply This device is designed for use indoors Observe the permissible ambient temperatures for use The device meets the requirements for electromagnetic compatibility Do not exceed the maximum values specified in the applicable standards O O O O 2 1 SCALE ASSEMBLY Indicator can be installed in FIXED and ADJUSTABLE mode a mi ADJUSTABLE MODE _ a ssi Screw the hole below Screw the hole above USER S MANUAL MA13 02 B 1 Route the cable through the 2 Route the cable through the base column and screw column to base 3 Tighten the three base screws by 4 Connecting the cable turning clockwise 5 Align the bracket on the base and tighten the screws NOTE Make sure that the weighing tray is installed properly and at the right position 7 Install the tray to the proper location D USER S MANUAL MA13 02 B 9 Assembly finished 10 Adjust four rubber feet to center bubble level 2 2 LOCATION AND SETTING We strongly recommend you use this device on flat and hard surface Any soft surface like carpet will cause inaccuracy 2 3 STARTUP o Connect the equipment to the power supply using the
5. bit 1 bit Handshake RTS CTS Data code ASCII 11 USER S MANUAL MA13 02 B USER S MANUAL MA13 02 B 5 MAINTENANCE AND CLEANING The scale does not require any routine maintenance However we recommend checking the scale s accuracy at regular intervals The regularity of these checks is dependent on the level of use and the state of the scale o We would recommend using alcohol based wipes or similar when cleaning the scale o Please do not use large amounts of water when cleaning the scale as this will cause damage to the scale s electronics you should also refrain from using corrosive liquids or high pressure washers o Always disconnect the scale from the main power supply before cleaning 5 1 INSTRUCTIONS FOR CHARGE AND CONNECT If Lo is displayed on the LCD you should charge scale with AC adaptor Locate adaptor plug at the rear of indicator CAUTION Always connect the AC adaptor to the indicator before connecting to the main power supply Please disconnect the adaptor from ma n power supply before indicator 5 2 INSTRUCTIONS FOR REPLACING BATTERIES Remove the battery cover Take the battery housing out Replace new batteries Make sure batteries are well installed Reinstall the battery housing Reinstall the battery cover O O O O O 5 3 ENVIRONMENTAL All batteries contain toxic compounds disposal of batteries should be delegated to a competent organization complying with the deposit of Poisonou
6. result on the display determine stable weighing value ZERO setting key To reset the display to 0 0kg display Zero the scale 2 of full capacity TARE button Tare weight during weighing process 3 3 WEIGHING Switch on the scale with the ON OFF key The diagnostic scale self check is performed and then the software version is displayed The scale is ready for weighing when the 0 00 kg weight display is shown NOTE If 0 00 kg won t display on the screen press gt 0 key to zero the scale gt 0 can be used any time to zero the scale Place a person in the middle of the scale Wait until the stability display 0 is shown and then read the weighing result DIRECTION Ifa person is heavier than the weighing range the display will show the Err symbol overload 3 4 TARING Tare allows the user to zero the instrument to cancel the weight of a container clothes from the reading of the instrument thus giving the true weight ofthe product person being tested Turn on the scale using ON OFF key When 0 00 kg displays on the screen and scale beeps twice place the object clothes to be tared on the tray Press TARE key after the weight stabilizes and stable sign appears on the display Display will return to 0 00 kg Place the item baby to be weighed without removing the tare object The weighing result is the Net weight of the item baby o To delete the saved tare value remove the tare ob
7. AC adaptor o Press the ON OFF button in the indicator o Wait until 0 appears on display USER S MANUAL MA13 02 B 3 OPERATION Before reading detailed instructions on how to use all the weighing functions that are built into your scale please read the following important guidelines o Always be sure that the display shows Zero before use if it does not then please press the ZERO key o The equipment is designed to detect when a stable weight is achieved your reading should be taken at this point 3 1 LCD SYMBOL DESCRIPTION PRE TARE Indication HOLD Indication NET WEIGHT Indication BMI _ ro Indication Stable MEN Minor weight lt ___ a Zero symbol lt Low Battery lt __ Description Zero symbol If the scale does not show exactly zero value although the scale pan is unloaded press the 0 lt key After a short waiting time the scale will be zeroed again Stable symbol If the display shows the stabilization display 0 the scale is in the stable condition When the scale is in the unstable condition the stabilization display o disappears pu Hold function saving function is active The net weight is displayed neo The present weight value is displayed USER S MANUAL MA13 02 B 3 2 KEY FUNCTIONS PRE BMI HOLD TARE NET WEIGHT DAVI amp CIA TARE www davicia com EA ERr HOLD Function ON OFF switch Turn ON OFF the scale HOLD button To hold weighing
8. by a serious fault on that the signal from the load cellis the scales such as faulty load cell or wiring Please too low contact the local service representative Zero count over calibration zero Please recalibrate the instrument range 10 while power on Zero count under calibration zero Please recalibrate the instrument range 10 while power on EEPROM Error Indicates that This error is normally caused by a serious fault on there is a fault with the scale s the scales such as faulty load cell or wiring Please software contact the local service representative 13 USER S MANUAL MA13 02 B 7 HEIGHT ROD ACCESSORIES AC2080D AC2080D is a digital height rod to be mounted on the scale with measuring range of 35 80cm AC2080D have LCD display for convenient accurate and quick height measurement AC2080M AC2080M is a mechanical height rod to be mounted on the scale with measuring range of 35 80cm AC2080M don t have LCD display 7 1 HEIGHT ROD ASSEMBLY a 1 Fix bracket on the tray with two screws 2 14 Assemble the height rod to the bracket USER S MANUAL MA13 02 B 3 Pressthebuckle to secure the height rod is well 4 Assembly complete installed 7 2 BATTERY INSTALLATION AC2080M don t need batteries to operate AC2080D Installing battery AAA 1 5V x 2 in battery housing next to LCD display WARNING If the height rod is not in use for long time take out the batteries and store th
9. e de 2010 DATE 12 December 2010 Nombre J Masana Name Firmado Cargo Gerente Function DAVI 8 CIA 21 USER S MANUAL MA13 02 B This manual and other support documents are available on the web www davicia com DAVI amp CIA C Murcia 35 Nave G Pol industrial Can Calderon Tel 3493 654 32 32 info davicia com E 08830 Sant Boi de Llobregat Barcelona Spain Fax 34 93 654 16 62 www davicia com 22
10. em separately in case of any leakage from battery would damage the measuring rod 7 3 KEY FUNCTIONS Keys Description O Z gt Z S ON OFF Press to switch on and off UNIT To select the measurement unit between cm and inch To enable value store function during measuring Current height value of user will be stored HOLD and displayed Press again to disable the function RESET key is for user to calibrate false reading Slide right feet piece to the left at length of 35cm Press RESET key to calibrate the height rod LCD will display 35 0cm which means the height rod has been well calibrated 15 USER S MANUAL MA13 02 B 7 4 CALIBRATING THE HEIGHT ROD AC2080D 1 Installing battery 2 PressON OFF to switch on LCD 3 Sliding feet piece left to the end 4 Press RESET button to calibrate at 35 0cm 7 5 USING THE HEIGHT ROD AC1200D 1 Extend the height rod for use 2 Place the baby with his head touching the left top of the height rod 3 Straighten baby s feet 16 USER S MANUAL MA13 02 B 4 Slide the right piece of the height rod until it touches the baby s feet 5 The LCD is displaying the baby s lenght 6 Press HOLD button to memorize the length reading 7 Press HOLD again to disable the function and return to normal mode AC1200M 1 Extend the height rod for use 2 Place the baby with his head touching the left top of the height rod 3 Straighten baby s feet
11. ject from the tread platform and press TARE key O O O O USER S MANUAL MA13 02 B 3 5 HOLD The scale is provided with the integrated hold function determination of average value It enables people to be weighed accurately although they are not still on the scale plate NOTE Determination of average value is not possible when a person moves too much o Switch on the scale with the ON OFF key The scale self check diagnostic is performed The scale is ready for weighing when the 0 00 kg weight display is shown o Place a person in the centre of the scale plate o Press the HOLD key When the triangle is flashing on the display the scale takes some measuring values and then the calculated average value is displayed o Remove the object baby from the scale platform The object baby s weight reading will remain on the display o Press the HOLD key again to return the scale to the normal weighing mode o HOLD function can be activated before or after putting the weight on the platform In case of weighing babies that move alot it is recommended to press HOLD key before the person moves on the platform USER S MANUAL MA13 02 B 4 SETUP Switch ON the scale and long press ZERO key for 3 seconds First SETUP and then A OFF will display successively Auto off time setup This enables operator to select the auto turn OFF time of the device Auto off time 120 sec 180 sec 240 sec 300 sec Off Buz
12. s Waste Regulation 1972 Please do not incinerate batteries The optimum operating temperature for the scale is 5 C to 35 C although it will operate at higher and lower temperatures the scale s battery life will adversely be affected 5 4 EQUIPMENT DISPOSAL All electrical and electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities This crossed out wheeled bin symbol on the product means the product is covered by the European Directive 2002 96 EC The correct disposal and separate collection of the equipment will help prevent potential negative consequences for the environment and human health It is a precondition for reuse and recycling of used electrical and electronic equipment 12 USER S MANUAL MA13 02 B 6 TROUBLESHOOTING Error Message Reason Action Low Battery This warning shows Please replace a new battery or plug the AC that the voltage of battery is too adaptor for operation low to use Overload The total load exceeds Please reduce the loading and try again the maximum capacity ofthe scale Counting error too high Indicates This error is normally caused by a serious fault on that the signal from the load cellis the scales such as faulty load cell or wiring Please too high contact the local service representative Counting error too low Indicates This error is normally caused
13. zer on off setup This enables operator to select beep sound ON OFF Buzzer On Off RIS 3 ess ZERO key seconds HOLD SEEUP ARES dL DFF 05 1905 2405 3005 FPF key means a ADFF i bile E N Un OFF al e A ARE Eng NOTE To confirm the settings please press HOLD when END displays on the display 4 1 CONNECTING WITH PC The equipment can be connected to PC to transfer the weighing results 1 Start Hyper Terminal Start Hyper Terminal program from clicking Start Menu Programs Accessories gt Communication gt Hyper Terminal New Connection Description Give new connection a name then click OK Select Your COM Port Click Connect to select your COM port Usually there s only one option for select Then click OK Port Settings Click Bits per second to set up rate at 9600 Data bits at 8 Parity at None Stop bits at 1 and Flow control at Hardware Then click OK to complete your setting Output Data When the patient has been weighed and BMI calculated simply press the PRINT key to output data from scale to PC or an Optional Printer Parameters of RS232 interface Set parameters of the scale interface on the connected device It is not possible to change the scale parameters O Baud rate 9600 bps 10 O O O O Parity check None Data length 8 bits Stop

Download Pdf Manuals

image

Related Search

Related Contents

lh010 eco blackbox series (ajouts au guide d`utilisation)    Buffalo Technology Network Router WCA-G User's Manual  

Copyright © All rights reserved.
Failed to retrieve file