2711C-UM001F-EN-P PanelView Component HMI User Manual

image

Contents

1. Obtain an IP address automatically IP address 183 254 253 Subnet mask 255 255 255 0 Default gateway OH ap JC ve dd e maittomahrcalh Ubtain DN server address automaucali Use the following DNS server addresses Prefered DNS server Alternate DNS server 109 Appendix C PanelView Component Emulator Uninstall the Emulator 110 The PanelView Component Emulator Microsoft device emulator and Virtual PC programs are listed as separate items in the Windows Add or Remove Programs list If you have multiple versions of the PanelView Component emulator you can remove whichever version you want The Microsoft device emulator and Virtual PC programs are still needed by the PanelView Component emulators that remain installed The PanelView Component uninstaller will not uninstall those components because they may be used by other software packages You are required to uninstall them separately if desired The PanelView Component uninstaller removes all registry settings files directories and Windows Start menu items that were originally installed with this component for more information see PanelView Component Extended Support Follow these steps to uninstall the emulator components 1 Go to the Control Panel under the Windows Start Menu 2 Select Add or Remove Programs and highlight PanelView Component Emulator v1 x Multiple versions of the PanelView Component Emulator can reside
2. Reboot the terminal Contact technical support providing this data ID1 S 0 Param1 ID2 S 0 Param2 P1 S 0 Param3 P2 S 0 Param4 P3 S 0 Paramb Reboot the terminal Contact technical support providing this data ID1 S 0 Param1 ID2 S 0 Param2 P1 S 0 Param3 P2 S 0 Param4 P3 S 0 Param5 P4 S 0 Param6 Reboot the terminal Contact technical support providing this data ID1 S 0 Param1 ID2 S 0 Param2 P1 S 0 Param3 P2 S 0 Param4 P3 S 0 Param5 P4 S 0 Param6 P5 S 0 Param7 Reboot the terminal Publication 2711C UM001F EN P November 2010 PanelView Component Terminal Alerts Category Communication Communication Server Error Communication Communication Server Error Communication 10 Write Error for Alias S 0 Param2 Controller S 0 Param3 Address is S 0 Param4 Communication Flag is S 0 Param1 The terminal is having troublewriting the external tag at this controller and address Read Error for Alias S 0 Param2 Controller S 0 Param3 Address is S 0 Param4 Communication Flag is S 0 Param1 Communication The terminal is having trouble reading the external tag at this controller and address Publication 2711C UMO001F EN P November 2010 Troubleshoot the System Chapter 6 Contact technical support providing this data ID1 8 0 Param1 ID2 8 0 Param2 P1 S 0 Param3 P2 S 0 Param4 P3
3. Wiring and safety guidelines Connecting devices MicroLogix controller cable charts Ethernet connection Serial connections lt blue link gt USB Ports Use publication NFPA 70E Electrical Safety Requirements for Employee Workplaces IEC 60364 Electrical Installations in Buildings ot other applicable wiring safety requirements for the country of installation when wiring the devices In addition to the NFPA guidelines connect the device and other similar electronic equipment to its own branch circuit protect the input powet by a fuse or circuit breaker rated at no more than 15 A route incoming power to the device by a separate path from the communication lines cross power and communication lines at right angles if they must cross Communication lines can be installed in the same conduit as low level dc I O lines less that 10V shield and ground cables appropriately to avoid electromagnetic interference EMI Grounding minimizes noise from EMI and is a safety measure in electrical installation For more information on grounding recommendations refer to the National Electrical Code published by the National Fire Protection Publication 2711C UMO01F EN P November 2010 Association 59 Chapter4 Cable Connections and Communication Connecting Devices Use these cables for connecting devices to PanelView Component terminals Cables for PanelView Component Terminals 2 11C CBL UUO2 USB A host to US
4. C300 Function and Numeric Keys Allen Bradley PanelView C300 p Config Language File Manager Current Application C600 C1000 Touch Screen File Manager Communication Display System Information Current Application Config Language nalishi Portugues Fran ais Italiano Deutsch Espa ol st 0 Reset Terminal Month Minute m E Year Second Publication 2711C UMO01F EN P November 2010 Configuration Mode Chapter 2 PanelView Explorer Startup Window The PanelView Explorer Startup window lets you access the terminal through a web browser 10 2 3 AB PanelView Component QUALITY Terminal Settings File Transfer Help Sign Off m Applications 7 Status Name Initial T10C l Location Internal Mode Running Initial_T10C Yes Internal Terminal PanelView C600 Color Status Connected to Terminal via Ethern Rus New Application 7 Create amp Edit i English Portugu s Fran ais Italiano Deutsch Espa ol itt E30 PanelView Explorer Startup Window Item Description 1 Terminal Settings Use this link to view and change terminal display and communication settings view system information and enable terminal security while connected to the terminal 2 File Transfer Transfers files between the storage media of the terminal and your computer You can transfer applications images fonts user defined objects screensav
5. Italiano Deutsch Espa ol et tH Year Second System Information Reset Terminal 2009 Display Follow these steps to change the language on the C200 and C300 terminals 1 Click Config Language Allen Bradley PanelView C200 P k Config Language 4 Pa Current Application fs vi Cc pum 2 Press F1 to select the language The display changes to the language you select immediately Allen Bradley PanelView C200 At runtime diagnostic messages appear in the same language as the application if the application language is English Portuguese French Italian German Spanish Chinese or Korean For all other languages the diagnostic messages appear in the configuration language set on the terminal IMPORTANT Adjust the Display Brightness and Contrast You can modify the brightness and contrast of the terminal display You can use the default intensity of 50 for contrast and 100 for brightness or adjust the intensity for runtime operations On the C600 2711C T6T and C1000 terminals only the TIP brightness can be changed 26 Publication 2711C UMO01F EN P November 2010 Configuration Mode Chapter 2 Follow these steps to change the display brightness and contrast using the PanelView Explorer Startup window 1 Go to the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the Display Input tab 4 Drag the slider to adjust the brightness level between 1
6. and in Edit Test Run mode to unload the currently loaded application PanelView Component Terminal Settings File Transfer Help Sign Off Stop Button Applications Name Initial T10C Location Internal Mode Running Initial TT C Terminal PanelView C600 Color Status Connected to Terminal via Ethernet Edit Test New Application Create amp Edit English Portugu s Fran ais Italiano Deutsch Espa ol itt ta To stop an application from the terminal go to the main configuration screen and reset the terminal and then reboot If you have not saved changes to the application you are prompted to do so Once the application is unloaded the terminal displays the Configuration screen 2 Close the web browser connected to the terminal Publication 2711C UMO01F EN P November 2010 15 Chapter5 Upgrade Firmware 4 Verify the existing firmware revision of the terminal by looking in the Configuration Screens and compare to the firmware revision of the file to make sure you are performing the desired upgrade Allen Bradley System Information Firmware Version 01 30 006 Boot Code Version 00 00 AN Logic Board Version 10 Terminal On Time 90 Display On Time O Battery Status Not Available Memory Usage bytes Internal Used 1 804 288 Internal Free 19 079 168 Application Used 9 379 840 pplication Free 39 686 144 Refer to View System
7. 100 5 Drag the slider to adjust the contrast level between 1 100 6 Click Apply or click Cancel to restore the current terminal settings DisplayAnput System Information Communication Terminal Security Display Input Devices Brightness 100 C Enable key repeat SSS SSS 777 Key Repeat Rate Contrast 50 oEIHeUS UA EE RSL Key Repeat Delay 375 Screen saver mode r Enable Screen Saver and Dimmer Reboot Terminal APRON alte Calibrate Touch Screen 1 minute v Screen saver brightness 5 Publication 2711C UMO001F EN P November 2010 27 Chapter2 Configuration Mode Follow these steps to change the display brightness or contrast from the terminal 1 Click Display on the menu list C200 C300 C600 C1000 Allen Bradley PanelView C200 Current Application File Manager TI b Display Config Language Date and Time Communication glish Hour Portugu s Francais Italiano Month Minute Deutsch x Espa ol Ey Year Second Display System Information 2 Use the arrow keys to adjust the brightness or contrast up or down On the C200 and C300 terminals press F3 to go to the contrast adjustment screen The change takes effect immediately The C600 2711C T6T and C1000 have only a brightness TIP control C200 C300 Brightness Allen Bradley PanelView C200 C600 Brightness and Contrast Hnanthess v A Calibrate E dad id A Touch
8. Adjusting Settings on the Terminal From the terminal you can view and edit the terminal settings The settings take effect immediately By clicking the menu items on the screen you can e switch to the currently running application y g app configure the terminal language change the current application adjust the display brightness and contrast configure screen saver settings calibrate the touch screen if supported reboot or reset the terminal view system information change the startup application change the current date and time set Ethernet network communication Publication 2711C UM001F EN P November 2010 Configuration Mode Chapter 2 Terminal Main Menu C200 C600 and C1000 D Allen Bradley Panel View C200 EN b Configu Config Language C300 Communication mE Q Allen Bradley PanelView C300 Portugues Fran ais Display Italiano P Config Language l Deutsch File Manager Espa ol Yv F1 F2 F3 Fa Pu Current Application gr H System Information Reset Terminal These settings can also be changed using the PanelView Explorer Startup Window Publication 2711C UMO001F EN P November 2010 23 Chapter2 Configuration Mode Adjusting Settings on the PanelView Explorer Startup Window From the PanelView Explorer Startup window you can view and edit settings for the connected PanelView Component terminal The settings take effect immediately By
9. If DHCP is enabled for the Ethernet port the current fields show the IP addresses assigned by the network You can assign IP addresses manually by disabling DHCP and entering addresses in the static fields Follow these steps to set a static IP address for the Ethernet port of the connected terminal using the PanelView Explorer Startup window 1 Go to the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the Communication tab TAB PanelView Component QUALITY Dashboard File Transfer Help Sign Off Displaynput System Information Communication Terminal Security MAC ID 00 00 8C 38 26 6F Network Device Name USMKEEXJT test USB Settings Ethernet Settings IP address Current IP address N h 0 90 95 30 Subnet mask Current Subnet mask 255 255 254 0 Default gateway Current Default gateway I 0 90 94 1 Use DHCP Static IP address 131 200 55 108 Static Subnet mask 255 255 255 0 Static Default gateway 131 200 55 1 one Cancel English Portugu s Fran ais Italiano Deutsch Espa ol f amp ffcex 50 4 Uncheck Use DHCP to manually enter IP addresses 5 Enter an IP address in the Static IP address field 6 Enter the default mask in the Static Subnet mask field 7 Enter the default gateway in the Static Default gateway field 8 Click Apply or click Cancel to restore the current IP address Publ
10. PanelView Component Emulator PVcEmLaunch Error Codes 0x2000B LU Failed launching the emulator 0x2000C a S Emulator failed to start timeout 0x2000D a RENI Failed launching web browser 118 Publication 2711C UM001F EN P November 2010 Appendix D PanelView Component DesignStation 2 0 Overview PanelView Component DesignStation 2 0 is an offline programming software J for PanelView Component PVc DesignStation 2 0 provides a significantly faster design experience compared to developing applications online with a terminal or an Emulator Applications developed using PVc DesignStation 2 0 can only run on terminals with Firmware Version 1 50 or later d P c DesignStation Startup Microsoft Internet Explorer provided by Rockwell Automation ini x File Edit View Favorites Tools Help Ld About PanelView Component DesignStation gt 555 96 5 75 9 0 Address C Program Files Allen Bradley Panel iew Component DesignStation www Start htm Ej co Links iconvert ec PanelView Component File Transfer Help Quit Application Dashboard Applications r Status Name Version Mode Terminal PanelView C 1000 New Application PanelView Component DesignStation 2 0 1 50 Platform 2711C T10C Create amp E dit 2711C T10C 2711C T6C 2711C T6T Portugu s Francais italiano Deutsch Espa ol epi ERO 2711C T6M Copyright 2008 Rockwell Automation
11. Pequres the most desk Dass OQ Express Only instal the Paneles Component Emulator testura i Recommended i previous complete nial already exists on this a CO Custom aL Chose which program Features you Mant matabod and where they A well be nistalied Feccmimended for achvarced users eee J mers J cmn 5 If you selected custom setup you to select individual components to install select install paths where appropriate and select install options where appropriate LE E P P iS PanelView Component Emulator v1 0 Custom Setup Salart the program faatures you vean insala Click on an ic n in hes Est below Eo change hoa a astura iS inst slled Merosoft DeviceEmulstor Microsoft Locoback Adapter Microscit Virtual PC 2007 Extended Support E De CAPregr em Plesier ade 105 Appendix C PanelView Component Emulator 6 Click Install to continue with the installation cancel to cancel the 5 process or back to make changes to your installation The verification screen gives you a chance to cancel the installation process before any permanent changes occur ie PanelView Component Emulator v1 0 Ready to Install the Program The wizard k raad bo basin indtsliticon Ole Inicial fo begin the inst alisron IF you want bo revi or change any of your inctalisron carnes click Back Click Cancel to exit the vazard Several software components are required for the Panelview Component Emulator
12. Portugu s Fran ais italiano Deutsch Espa ol itt ERO Publication 2711C UM001F EN P November 2010 Configuration Mode Chapter 2 Publication 2711C UMO001F EN P November 2010 Follow these steps to change the terminal date and time from the C600 and C1000 terminals l Go to the Main configuration screen File Manager Current Application Config Language Date and Time Communication mm Day Hour Portugues 5 Fran ais i hala Italiano puer Deutsch z Espa ol O System Information Reset Terminal 2 Click on the number next to what you want to change under the Date and Time section A numeric keypad is displayed 3 Select the numbers you want and click the enter key Date and Time Month Minute E B Year Second system Information Reset Terminal 2000 E 43 Chapter 2 44 Configuration Mode Change Ethernet Settings You can establish an Ethernet connection between the connected PanelView Component terminal and computer using the Ethernet port or the host USB port on the terminal For the Ethernet port IP addresses can be set dynamically by the network if Dynamic Host Configuration Protocol DHCP is enabled If DHCP is disabled the IP addresses must be entered manually IMPORTANT If a terminal is set for DHCP and is not on a network or IS on a network that does not have a DHCP server or the server is not available it will automatically assign itself an Au
13. You will not be notified when Windows Firewall blacks programs Selections on the Exceptions tab will be ignored 9 Avoid using this setting Turning off Windows Firewall may make this computer more vulnerable to viruses and intruders Windows Firewall is using your domain settings Aa EEE E E Se lee D A M ME SC S E cC mcd Me Dre se dM Iq SEDIS IS D Tua meee E M hat elze should know about Windows Firewalls 6 Check that the Windows Firewall is off Click the OK button 7 Click the General tab for connection properties 136 Publication 2711C UMO01F EN P November 2010 Firmware Update Utility Appendix E 8 Check that the Internet Protocol TCP IP box is selected and no Publication 2711C UMO001F EN P November 2010 other protocols are selected J Local Area Connection 12 Properties Configure O WF Network Monitor Driver Ol iPass Protocol IEEE 802 1 v3 4 9 0 W Internet Protocol TCP IP I Install Uninstall Description Allows your computer to access resources on a Microsoft network Show icon in notification area when connected Notify me when this connection has limited or no connectivity 9 Select Internet Protocol TCP IP and click the Properties button 10 Check that the following IP address and Subnet Mask are set e IP address 169 254 254 1 e Subnet mask 255 255 0 0 Internet Protocol TCP IP Properties AETERNE General T ou can get IP
14. be lost Alert 2050 The value is not within the minimum and Enter a value within the allowable range If you do maximum range not know the range Edit the application to determine the allowable range for the device Alert 2051 Allow Autorun Press No to disallow Autorun Alert Application has been modified Allow Autorun Press No to disallow Autorun Edit the application and save prior to performing this operation otherwise changes to the application may be lost Alert 2053 Screen switching controlled by external source Screen navigation devices are disabled ifthe screen has been changed to via controller Alert Cannot reset the terminal in Safe mode Terminal reboot is disabled on the emulator Select Flash gt Save and then select File gt Reset gt Hard to reboot the emulator Alert 2055 Image exceeds maximum resolution of 800x800 Open file in image editor and reduce the resolution NO Co C1 NO NO c C1 I 88 Publication 2711C UM001F EN P November 2010 Troubleshoot the System Chapter 6 PanelView Component Terminal Alerts Alert 2056 Cannot copy recipe to a loaded application Please unload application and try again Alert 2057 Terminal is running low on application memory Please reset the terminal or this may lead to fatal lt Available_Virtual_Memory gt bytes error Alert 2058 Failed setting property S 0 Param1 S 0 Verify the range of the numeric display that uses the
15. i 4 Click Next to start the installation ie Panel iew Component Firmware Update Utility Installation Complete Panelview Component Firmware Update Utility has been successfully installed Click Close to exit Please use Windows Update to check for any critical updates ta the MET Framework Eancel 5 Click Close when the installation is complete This section shows how to update the firmware image on a nonoperating terminal Follow these steps to update the firmware image on the terminal 1 Connect the USB host port of your computer to the USB device port on the terminal 2 From the Start Menu select Programs gt Allen Bradley gt PanelView Component Firmware Update Utility Publication 2711C UMO01F EN P November 2010 Firmware Update Utility Appendix E 3 When the utility is running make sure Update Firmware is checked connect requeste x 4 Click the Browse Button to select an SC image for example SC 01 01 002 IMG The SC image is typically obtained from the PanelView Component technical support website When a valid SC image is opened the version information is extracted and displayed 5 Click the Begin Waiting for Connect Requests button to start the firmware update The utility is waiting for an update request from the terminal Started listening ror BOOTHE requests on port 382 6 Reset the terminal Momentarily open the USB connection at the same
16. 47 48 51 52 terminal settings 22 brightness and contrast 26 calibrate touch screen 34 39 date and time 42 enable terminal security 47 Publication 2711C UMO01F EN P November 2010 Ethernet 44 key repeat 33 on PanelView explorer startup window 24 22 reboot terminal 36 screen saver 29 50 terminal language 25 transfer applications 53 user defined objects 56 troubleshooting 81 90 alerts 81 check for power 90 status indicators 91 U Publication 2711C UMO01F EN P November 2010 Index Uninstall DesignStation 122 update firmware on nonoperating terminal 130 USB device port 65 flash drive 57 host port 64 install driver 65 ports 13 user defined objects 56 Using DesignStation 125 W wiring and safety guidelines 59 141 Index 142 Publication 2711C UMO01F EN P November 2010 Rockwell Automation Support Rockwell Automation provides technical information on the Web to assist you in using its products At http www rockwellautomation com support you can find technical manuals a knowledge base of FAQs technical and application notes sample code and links to software service packs and a MySupport feature that you can customize to make the best use of these tools For an additional level of technical phone support for installation configuration and troubleshooting we offer TechConnect support programs For more information contact your local distributor or Rockwell Automation re
17. C Program Files i Adobe 9 Adstream E 3 Allen Bradley H Panelview Component DesignStation C Config Fonts ic Images ic KeplektaData E KepServerEx ic Drivers i Projects ic MetaData G supo c Temp pps ic TextData 3 Validation E E wan 9 Cache DeviceIcons ic Image Zl i Script i Library 3 Validation Style The install directory under the root is named PanelView Component DesignStation This folder contains the files required for launching the software Launch PanelView Component DesignStation 2 0 via the Launch PVc DesignStation entry in your Windows Start Menu or by double clicking the Launch PVc DesignStation shortcut on your desktop Publication 2711C UM001F EN P November 2010 PanelView Component DesignStation 2 0 Appendix D Windows Start Menu The PanelView Component DesignStation 2 0 installer creates an entry in the Windows Start Menu that can be used to launch the software The shortcut is installed for all users l SUV LDI IUtuyc Adobe ExtendScript Toolkit CS4 Allen Bradley gt PanelView Component DesignStation beta Adobe Help Center fm Panel iew Component DesignStation HE P c DesignStation 3 Internet Explorer P c DesignStation Help Windows Media Player Windows Movie Maker Using PanelView PanelView Component DesignStation 2 0 lets you create applications without i i bei d inal Component DesignStation 8 e to a termina 2 0 TIP When using Pa
18. Cable Connections and Communication 6 If the Windows Logo Test warning dialog box is displayed click Continue Anyway Software Installation The software you are installing has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is i tant Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the software vendor for software that has passed Windows Logo testing STOP Installation 7 Click Finish in the Device Driver Installation Wizard dialog box Device Driver Installation Wizard Completing the Device Driver Installation Wizard The drivers were successfully installed on this computer You can now connect your device to this computer If your device came with instructions please read them first Driver Name Status E v Allen Bradley Company LLC Allen Bradley Ready to use gt 8 Click Finish in the PanelView USB RNDIS Driver dialog box i PanelView USB RNDIS Driver InstallShield Wizard Completed The InstallShield Wizard has successfully installed Panelview USB RNDIS Driver Click Finish to exit the wizard The drivers are now installed Publication 2711C UMO01F EN P November 2010 Cable Connections and Communication Chapter 4 Publication 2711C
19. Chapter 6 Chapt t OD EC IVES ia to eee user PET 81 View Systemi InFoFtHidtlO 29s vet pda pou EEEE E eee o1 SUI MENFE Sate eh TET T ds er ae ft Oe a CRI 81 Troubles hoon ea oam dade Gace tie a Sete Bal E uno pc dta ode 90 Returning to the Out of box Condition vere bTRRD PERS 92 Appendix A General SPeCINCANONS se vp d Ves dete dw e END DA DN ds 95 BE nvitontieblbll uer Wire es ie cbse de EEA E E 96 CCT CA TONG deal i o ih oe bh St Dp eh a eodd ei ee ISO dE 97 Appendix B JAowvallable DOBtscus e tuas ved eS SS en ORCA REE CAG EARS 99 Set up Fonts for PanelView Component DesignStation 2 0 99 Impott aA Font Dead aca eed ele ae SUR Donde ire ap dte Bae tre d 99 Remove a Font File serer er ensi hab nU pe 100 Appendix C AUS AUI ERANT RESET TI TII 103 Installhthe Emillatots conce rr Roh OCEa A EE E AL RC ene 103 Inmstallthe E imulator xxt t ardeo OS EPUEASDEDg e IER P 110 Directory Layoutand Content cua d reir bot t te Eae Renesas 112 Launch Meehafitsth a uuo E EEUU E ES Ip 114 Usihp tbe Emut Suus PESE FRE ILU P Ete aos 115 IE ELI E 3s ER ICPTTTITOCOTET T hha T ao TCPPDT 117 Appendix D Dae na Keira peer Sete Le A wie d ee din 8 Rebs Go UA p gud c ers D Bod 119 About PanelView Component DesignStation 2 0 119 Install the SOPfDBWAEG vv rx LIS AIRE ru EAE SR BSS 120 Uninstall the DesignStation Software 0 0 eee eee eee 123 Directory Mayout and CODtOHE osasi edhe e E C Re ees qs 124 Launch Mechanism
20. Configuration Mode Chapter 2 7 In the Reset Password dialog enter a new password confirm the password then click OK TIP Terminal user names and passwords are limited to 15 characters Reset Password Confirm New Password 30 minutes 8 Select a new idle timeout from the Terminal Idle Timeout list if needed or click Cancel to restore the current idle timeout The new password and idle timeout value take effect when the terminal is restarted To disable security uncheck the Terminal Security Enabled checkbox The next time the terminal is restarted the design environment is unsecured TIP The terminal user name and password is stored in a file that is separate from the application You can transfer this file to other terminals without having to manually re enter the information Use the File Transfer link on the PanelView Explorer Startup window and transfer the Terminal User file from internal storage to your computer USB or SD storage Publication 2711C UM001F EN P November 2010 49 Chapter2 Configuration Mode View System Information You can view system information about your terminal including information about the firmware boot code logic board battery status if applicable terminal on time and memory used Follow these steps to view system information using the PanelView Explorer Startup window 1 Go to the PanelView Explorer Startup window 2 Click the Terminal Settings li
21. Files Currently on the CD USB Driver File Folder 1 25 2008 12 59 PM Files Currently on the CD Emulator File Folder 1 25 2008 1 00 PM Files Currently on the CD Extended Support File Folder 1 25 2008 1 01PM Files Currently on the CD Publish this folder to Documents File Folder 1 25 2008 1 03 PM Files Currently on the CD the Web Tools File Folder 1 25 2008 1 04PM Files Currently on the CD File and Folder Tasks A ia Share this folder B Readme txt 1KB Text Document 9 11 2007 2 48 PM Files Currently on the CD Other Places 65 Chapter4 Cable Connections and Communication 2 Run the installer Panel View Component USB Drivet exe D AUSB Driver Fille Edit View Favorites Tools Help Qsek BD sede Folders 3 Address e D USB Driver Size Type 3 065KB Application 1 24 2008 2 49 AM Files Currently on the CD ix The installer extracts and runs an Install Shield Wizard InstallShield Wizard E Wi PanelView USB RNDIS Diver Setup is preparing the InstallShield See Wizard which will guide you through the program setup process Please wait Extracting Panelview USB RNDIS Drrver msi Cancel 3 Click Next when the Welcome dialog box appears i PanelView USB RNDIS Driver Welcome to the InstallShield Wizard for PanelView USB RNDIS Driver The InstaliShield R Wizard vill install Panelview USB RNDIS Driver on your computer To continue click Next WARNING This p
22. Input Devices Brightness 100 C Enable key repeat Key Repeat Rate o Contrast 50 2 7 Ja Key Repeat Delay LE 0 5 m Reboot Terminal Calibrate Touch Screen 36 Publication 2711C UMO01F EN P November 2010 Configuration Mode Chapter 2 Follow these steps to reboot the terminal from the C600 and C1000 terminals 1 Go to the Main configuration screen 2 Press Reset Terminal Current Application Config Language Date and Time Communication T Day Hour Portugues Frangais cu Italiana Dur Deutsch z Espa ol z st 01 System Information Reset Terminal 2 na File Manager 23 Confirm reset Follow these steps to reboot the terminal from the C200 and C300 terminals 1 Select Reset Terminal from the menu list Allen Bradley PanelView C300 Screen Saver Sistem Information b Reset Terminal 2 Press F1 to reset the terminal Allen Bradley PanelView C300 Publication 2711C UMO001F EN P November 2010 37 Chapter 2 38 Configuration Mode 4 Confirm restart Allen Bradley PanelView C300 Publication 2711C UMO01F EN P November 2010 Configuration Mode Chapter 2 Change the Startup Application You can select or change the application that runs on the terminal each time the terminal starts up You must also select the storage location of the application The options are internal storage of the terminal USB flash drive SD card or PC storag
23. application may result in unexpected ehavior 3 Click the Save icon to save the application 4 Click the Close Application icon to close the application Tra nsferring User defined You can transfer user defined objects chu also known as library objects Ob j ects created in one application to another terminal for use with other applications In your application the user defined objects are added to the graphics library of the object palette They are stored in terminal storage separate from the application and can be accessed from any application on the terminal or emulator The names of user defined objects must begin with an alpha character 56 Publication 2711C UM001F EN P November 2010 Chapter 3 Install and Replace Components Chapter Objectives This chapter shows how to install replace or upgrade various components of the PanelView component terminals e SD memory card e USB flash drive e Battery replacement SD Memory Card The SD memory card can be inserted in this location on the C600 and C1000 terminals SD Memory Card Slot USB Flash Drive The USB flash drive can be inserted in these locations on the terminals USB Connector C200 and C300 USB Connector C600 and C1000 Publication 2711C UMO01F EN P November 2010 57 Chapter 3 Install and Replace Components Battery Replacement The C600 and C1000 terminals contain a lithium battery that is intended to be replaced during the
24. components 57 intended audience 9 Internet Group Management Protocol IGMP 62 IP address of terminal 12 Fthernet port 13 44 USB port 13 44 K key repeat setting 33 L Launching DesignStation 124 M managing applications 52 files 52 MicroLogix cable charts 60 0 objectives 9 operating systems 18 out of box condition 92 overview 11 P PanelView Component DesignStation 2 0 119 PanelView component emulator 103 PanelView explorer window 21 brightness and contrast 27 calibrate touch screen 34 39 date and time 42 Ethernet settings 45 key repeat setting 33 reboot terminal 36 screen saver 29 50 terminal security 48 peripheral connection 16 reboot terminal 36 C200 and C300 37 PanelView explorer window 36 recovery operations 12 remove fonts 100 replace screen saver image 32 runtime 19 S screen saver 29 C200 and C300 31 30 modes 29 PanelView explorer window 29 replace image 32 SD memory card 57 serial connections 63 RS422 and RS485 64 Simple Network Management Protocol SNMP 62 SNMP Protocol 62 specifications 95 certifications 97 environmental 96 general 95 supported browsers 18 system information 50 81 C200 and C300 51 52 PanelView explorer window 50 T terminal brightness and contrast 28 calibrate touch screen 35 41 40 date and time C600 and C1000 43 Ethernet settings C600 and C1000 46 interface 20 language 25 26 reboot terminal C200 and C300 37 screen saver C200 and C300 31 30
25. eee 124 Publication 2711C UMO01F EN P November 2010 Firmware Update Utility Index Publication 2711C UMO001F EN P November 2010 Table of Contents Using PanelView Component DesignStation 2 0 125 Appendix E Cape ID OCU em 127 DOU He DIET mos irit eite a Suit dap eer dei Pe 123 PSA the UU ena d reto dob toria diag ene ra dci aa a ded 129 eate DIE ATE uuu esr ui an oye QNS GARA tas wis ated E MA eu eo 130 Clean File System or Clean Registry s cesi wears REP TRIP VES 133 Resolve Fitmware Upgrade Issues a cect wt ro C Ed eS 135 Software Vain tenance sins a auis oder a e o edo e ERA RS des 138 Table of Contents 8 Publication 2711C UMO001F EN P November 2010 Preface Objectives Intended Audience Additional Resources Publication 2711C UMO001F EN P November 2010 This preface provides information on these topics e ntended audience e Additional resoutces e Firmware upgrades Use this manual if you ate responsible for operating or troubleshooting the PanelView Component terminals This manual provides information for configuring the PanelView Component terminal You can configure the terminal on the terminal through a web browser on a computer connected to the terminal through the PanelView Component emulator or the PanelView Component DesignStation 2 0 This manual does not give procedures for creating applications that run on the terminal No special knowledge is required to und
26. firmware upgrade e A corrupted file system that blocks the operating system e A corrupted Windows registry that blocks the operating system The utility always requires a companion firmware image SC XX XX IMG even if you are only performing a Clean File System or Clean Registry operation The utility is on the CD that is shipped with your terminal and the firmware image is downloaded from the website http ab com eoi eraphicterminals panelviewcomponent html 127 Appendix E Firmware Update Utility The utility lets you perform these operations separately or together e Update Firmware installs a new or changed firmware image e Clean File System formats the entire file system All user added content and user applications in the file system are erased including all changes to the Windows registry The system reverts to a default registry This operation also performs a clean registry operation since the registry is a file e Clean Registry erases all changes to the Windows registry The system reverts to a default registry This operation removes registry settings such as the user s selected startup application but does not remove user applications from the terminal The main dialog of the utility looks like this You can perform maintenance operations separately or together by clicking the corresponding checkboxes The screen shows all boxes checked i Maintenance Utilities 9 Abc Begin waiting for Afte
27. life of the product The battery provides battery backup for the real time clock It is not used for application backup or retention Verify that power has been removed from the terminal prior to replacing the battery Work in a static free environment and wear a properly grounded electrostatic discharge ESD wristband Be careful when touching any of the exposed electronic components to prevent damage from ESD To avoid the danger of explosion only replace the battery with 2711P RY2032 or a manufacturers equivalent such as the Matsushita or Duracell DL2032 For safety information on the handling of lithium batteries see the Guidelines for Handling Lithium Batteries publication AG 5 4 Do not dispose of battery ina fire or incinerator Dispose of used batteries in accordance with local regulations The battery is on the back of the terminals No special tools are required to remove the battery cover and replace the battery This equipment is sensitive to electrostatic discharge ESD Follow ESD prevention guidelines when handling this equipment At the end of its life the used battery should be collected separately from any unsorted municipal waste and recycled 58 Publication 2711C UMO01F EN P November 2010 Chapter Objectives Wiring and Safety Guidelines Chapter 4 Cable Connections and Communication This chapter provides network and device connections for the terminals
28. password has been marked as unmodifiable Edit the application and go to the Security tab Check the Modifiable box associated with the username and password Alert 2039 Cannot change password because no user is Log on as one of the users defined in the application logged onto the terminal and retry Alert 2040 Old password does not match the password for Enter the current user s password for the Old the current user Password Alert 2041 Cannot reset password this is an unknown user Log on as one of the users defined in the application and retry Alert 2042 Cannot change password new and confirm Verify the new password matches the confirmed passwords don t match password and retry Alert 2043 Access Denied The username password is either incorrect or the user does not have the access right for the associated screen Alert 2044 Cannot run application while in Safe mode Reboot the terminal to exit Safe mode and retry Alert 2045 Cannot run applications from external storage Copy or save to internal storage and try again Alert 2046 Passwords cannot be modified while in test The change password and reset password devices mode are only enabled while in Run mode Alert 2047 File is read only Continue Choosing to continue will overwrite the read only file Alert 2048 Application has been modified Continue Edit the application and save prior to performingthis operation otherwise changes to the application may
29. to reload the application to see if the recipe is Param2 failed Cause Recipe file not still there or restore from a cha file from your accessible computer or SD card 1026 Recipe Upload Failed This message is for informational purposes No corrective action needed 1027 Recipe operation in progress This message is for informational purposes No corrective action needed 2000 Loading This message is for informational purposes No corrective action needed Unloading This message is for informational purposes No corrective action needed 2001 2002 Terminal is starting up This message is for informational purposes No corrective action needed 2003 Application is currently being edited user input is Put the application into Test or Run mode to enable disabled user input 2004 Copying file This message is for informational purposes No corrective action needed 2005 Deleting file This message is for informational purposes No corrective action needed 2006 Operation failed This message is for informational purposes No corrective action needed Operation succeeded This message is for informational purposes No corrective action needed 2007 2008 Cannot run application Application version Edit validate and then save the application with incompatible this version and try again 2009 Cannot run application Communication Terminal does not support the communication connection no
30. upload completed successfully This message is for informational purposes No corrective action needed Recipe 1012 Recipe restore failed Cause Operation This message is for informational purposes No cancelled corrective action needed Recipe 1013 The status data point for Recipe S 0 Param1 Check for operation could not be written to Data Point S 0 Param2 Communication errors Bad status data point specification The status value written is outside the Low EU and High EU limits of the numeric data point assigned These are optional OPC defined properties representing data point minimum and maximum values The status value could not be converted to the type of the data point assigned Recipe 1014 Recipe download failed Cause The value S 0 Correct the dataset value Param1 is less than the minimum value S 0 Param2 allowed for ingredient S 0 Param3 Recipe 1015 Recipe S 0 Param1 failed Cause No Selector Add a recipe selector device to the screen on display Recipe 1016 Recipe S 0 Param1 failed Cause No DataSet Add a dataset selector device to the screen Selector on display Recipe 1017 Recipe 5 0 Param1 failed Cause NoTable on Add a Recipe Table Panel device to the Screen display Recipe 1018 Recipe S 0 Param1 operation was not started Wait for a recipe operation to complete before because the system is currently busy performing starting the next
31. www rockwellautomation com Power Control and Information Solutions Headquarters Americas Rockwell Automation 1201 South Second Street Milwaukee WI 53204 2496 USA Tel 1 414 382 2000 Fax 1 414 382 4444 Europe Middle East Africa Rockwell Automation NV Pegasus Park De Kleetlaan 12a 1831 Diegem Belgium Tel 32 2 663 0600 Fax 32 2 663 0640 Asia Pacific Rockwell Automation Level 14 Core F Cyberport 3 100 Cyberport Road Hong Kong Tel 852 2887 4788 Fax 852 2508 1846 Publication 2711C UM001F EN P November 2010 Supersedes Publication 2711C UMO001E EN P April 2010 Copyright 2010 Rockwell Automation Inc All rights reserved Printed in the U S A
32. 01 30 006 Boot Code Version 00 00 Logic Board Version 10 MN Terminal On Time 90 Display On Time O Battery Status Not Available ii Memory Usage bytes Internal Used 1 804 288 Internal Free 19 079 168 Application Used 9 379 840 pplication Free 39 686 144 Refer to View Svstem Information on page 50 for instructions on how to view the current firmware version Publication 2711C UMO01F EN P November 2010 Upgrade Firmware Chapter 5 Publication 2711C UMO001F EN P November 2010 2 Insert the storage device into a USB host port or the SD card slot that is on your terminal 3 When prompted to run the Autorun press Yes or the F1 key The splash screen appears and the progress bar indicates a firmware installation is in process Do not remove the SD card or USB flash drive until upgrade OK is displayed When the firmware installation is complete and successful the progress bar stops with the success code OK 4 Remove the storage device and reboot the terminal 5 Open the system information screen to see the firmware version that is expected after the installation Allen Bradley PanelView C300 SIGN atoms Firmware Version 01 30 006 Boot Code Version 00 00 Logic Board Version 10 Terminal On Time 90 Display On Time O Battery Status Not Available Memory Usage bytes Internal Used 1 804 288 Internal Free 19 079 168 Application Used 9 379 840 ppli
33. 010 Follow these steps to configure the screen saver from the C200 and C300 terminals 1 Select Screen Saver on the menu list and press the enter key Allen Bradley PanelView C300 Display b Screen Saver System Information 2 Press F1 to select the Mode Mode Image Disable Dimmer Image and Dimmer Allen Bradley PanelView C300 Screen Saver giji ij HTI 3 Press F3 and use the arrows to select the brightness Brightness 1 100 increments of 1 Allen Bradley PanelView C300 Screen Saver Allen Bradley PanelView C300 5 Press F1 to select the time Choices are 1 2 5 10 15 20 30 or 60 min 31 Chapter 2 Configuration Mode Replace the Screen Saver Image The default screen saver image is a floating Allen Bradley logo in a bitmap format The name of the default screen saver is Screen Saver with a bmp file type You can replace the default screen saver with your own bitmap image but the file must have the same name as the default screen saver To replace the screen saver image 1 2 Create a small bitmap image no larger than 128 x 128 pixels Save your bitmap file to your computer a USB drive or and SD card Rename your file as Screen Savet and make sure the file type is bmp Click the File Transfer link in the PanelView Explorer Startup window then click New Transfer Select either My Computer or USB SD Storage as file source depending on where you saved y
34. 11C T6T and 2711C T10C only using an Ethernet connection to connect to the terminal e Windows XP e Windows Vista e Windows 7 Connecting to a terminal using a USB connection is not compatible with Windows 2000 operating system The PanelView Component Emulator is not compatible with Windows 2000 operating system A user application can be created or edited through a browser connected to a terminal or emulator or through PVc DesignStation Ethernet network and USB connections are supported for connection to a physical terminal For the emulator the emulator and browser must be on the same computer Internet Explorer 7 8 Firefox 3 0 Terminal and emulator Internet Explorer 7 8 PVc DesignStation 2 0 Publication 2711C UM001F EN P November 2010 AB QUALITY Applications Name Initial T10C Location Internal Mode Running initial Tt0C Configuration Mode Chapter 2 If you use a browser other than a recommended browser this message appeats PanelView Component Terminal Settings File Transfer Help Sign Off For an improved experience while using this application itis recommended that you use A e Microsoft Internet Explorer 7 0 or higher or e Mozilla s Firefox Do not ask me again Terminal PanelView C600 Color Status Connected to Terminal via Ethernet New Application Create amp E dit English Portugu s Fran ais Italiano Deutsch Espa ol ffc EtO
35. 50 x 308 x 54 mm 9 84 x 12 13 x 2 13 in Value 0 50 C 32 122 F 25 70 C 13 158 F 16 BTU hr 32 BTU hr 58 BTU hr 0 95 noncondensing 15gat11 ms 30 g at 11 ms 2 g at 10 500 Hz NEMA UL Type 4X indoor 12 13 and IEC IP54 IP65 2711C T6M 2711C T6C Series B only NEMA UL Type 12 13 and IEC IP54 Publication 2711C UM001F EN P November 2010 Specifications Appendix A Certifications Certifications when Value product is marked c UL us UL Listed Industrial Control Equipment certified for US and Canada See UL File E113724 CE European Union 2004 108 EC EMC Directive compliant with EN 61000 6 2 Industrial Immunity EN 61000 6 4 Industrial Emissions C Tick Australian Radiocommunications Act compliant with AS NZS CISPR 11 Industrial Emissions 1 See the Product Certification link at http ab com for Declarations of Conformity Certificates and other certification details Publication 2711C UM001F EN P November 2010 97 Appendix A Specifications Notes 98 Publication 2711C UM001F EN P November 2010 Appendix B Adding Font Files Available Fo nts These fonts reside on the terminal in the firmware image e Arial e Courier New e Tahoma e Asian Font Simsun Simplified Chinese You can change the Asian Font firmware image from Chinese to Korean or Korean to Chinese by using the firmware upgrade method described in Chapter 5 The Arial Courier and Tahoma fonts ca
36. 57xx Gigabit Controller LB Local Area Connection 40 LAN or High Speed Internet Connected Microsoft Loopback Adapter Wireless Network Connection LAN or High Speed Internet Disabled Dell Wireless 1390 WLAN Mini Card 41 1394 Connection LAN or High Speed Internet Disabled 1394 Net Adapter 2 Select Properties 3 Make sure the Internet Protocol TCP IP box is checked highlight Internet Protocol TCP IP and select Properties Local Area Connection 40 Properties General Advanced Connect using 2 Microsoft Loopback Adapter This connection uses the following items M E File and Printer Sharing for Microsoft Networks iPass Protocol IEEE 802 1 v3 4 9 0 Description Transmission Control Protocol Internet Protocol The default wide area network protocol that provides communication across diverse interconnected networks Show icon in notification area when connected Notify me when this connection has limited or no connectivity 108 Publication 2711C UMO01F EN P November 2010 PanelView Component Emulator Appendix C Publication 2711C UMO001F EN P November 2010 4 Vetify that this IP address and Subnet Mask are set IP address 169 254 253 15 Subnet mask 255 255 255 0 Internet Protocol TCP IP Properties a General You can get IP settings assigned automatically if your network supports this capability Otherwise you need to ask your network administrator for the appropriate IP settings
37. B B device cable 2 m C200 C300 C600 6 56 ft C1000 2711P CBL EX04 Ethernet crossover CAT5 cable 4 3 m 14 ft C600 C1000 2711C RCSD USB to SD adapter with secure digital SD C200 C300 C600 card C1000 1747 CP3 Serial 9 pin D shell to 9 pin D shell null C200 C300 C600 modem cable C1000 1761 CBL PM02 Serial 9 pin D shell to 8 pin mini DIN cable C200 C300 C600 2 m 6 56 ft C1000 2111C CBL ABO3 RS 485 5 pin to RJ45 cable C200 C300 C600 C1000 Micro Logix Co ntroller The chart provides a summary of terminal connections to controllers C abl e Ch arts and network interface modules PanelView Component Terminals to MicroLogix Controllers Protocol PanelView MicroLogix 8 pin MicroLogix MicroLogix MicroLogix Component Port Mini DIN 1000 9 pin D shell 1100 1400 RS485 1100 1400 Ethernet 1100 1400 1500LRP Ch 1 1763 NC01 1200LSP 1500LSP Ch 0 DFI RS232 1761 CBL PM02 1747 CP3 N A DH 485 RS232 1761 CBL PM02 1747 CP3 Use AIC module N A 1761 NET AIC connect to port 3 RS485l1 N A N A Belden 3106A or N A 9842 or equivalent Modbus RS232 1761 CBL PM02 1747 CP3 Use AIC module N A 1761 NET AIC connect to port 3 Ethernet Ethernet N A N A N A CAT 5 Ethernet MicroLogix ENI 2 RS485 is non isolated and is recommended for connecting to only one device with an isolated port 60 Publication 2711C UM001F EN P November 2010 Ethernet Connection Publication 2711C UMO001F EN P November 2010 Cabl
38. H Runtime Configuration The runtime configuration is when you make changes on the actual terminal Changes can be made whether an application is running or not running C200 C600 and C1000 Do Allen Bradley PanelView C200 D Config Language irati nain File Manager Current Application DA foto Config Language Date and Time Communication m Hour Portugu s Fran ais Italiano Month Minute Q Allen Bradley PanelView C300 Display Db Sento ignia iid Deutsch EJ File Manager Espanol uz Current Application S Year Second System Information Reset Terminal ENS Publication 2711C UMO001F EN P November 2010 19 Chapter2 Configuration Mode Configuration Interfaces C200 Function Keys D Allen Bradley Panel View C200 EN x Current Application 4 P C200 Function and Numeric Keys Allen Bradley PanelView C200 P Config Language Current Application 20 Terminal settings can be configured either on the terminal or through a web browser using the PanelView Explorer Startup window Terminal Interface The on terminal interface lets you make changes to the terminal configuration On the C200 and C300 terminals you have to use the arrows to scroll through the menu The C600 and C1000 terminals have the menu displayed on the left side of the terminal screen C300 Touch Screen Allen Bradley PanelView C300 gt Config Language File Manager Current Application v MET
39. ION If deleting a font from the emulator internal storage you need to Flash Save for it to be permanently stored in emulator Otherwise it will be lost once you shut down To save to internal storage select Flash and then Save from the emulator s main window menu Font files especially East Asian Fonts are large and consume significant space on Internal Storage Remove all unused fonts from the terminal 101 Appendix B Adding Font Files Notes 102 Publication 2711C UM001F EN P November 2010 Overview Install the Emulator Publication 2711C UMO001F EN P November 2010 Appendix C PanelView Component Emulator The PanelView Component terminal emulator is treated as a terminal and runs almost the exact same firmware The emulator has its own file system One folder of the file system PC Storage can be mapped to a folder in your computer s file system Anything stored in the mapped folder can be accessed by both the emulator and your computer By default on the emulator applications are saved to the mapped folder PC Storage The PanelView Component Emulator can be installed on computers running Windows XP SP2 or Windows Vista For better emulator performance your computer should have at least an Intel Pentium M 1400 MHz processor with 512MB RAM Your computer information can be found by right clicking on My Computer and selecting properties The PanelView Component Emulator Installer installs the fol
40. Inc All Rights Reserved 2711C T3M 2711C K3M z 2 Done 2711C F2M D My Computer Z In PanelView Component DesignStation 2 0 the following features are not yet implemented validation run mode test mode PanelView Component DesignStation 2 0 only supports Internet Explorer 7 and 8 No other Internet browsers are supported at this time Publication 2711C UMO001F EN P November 2010 119 Appendix D PanelView Component DesignStation 2 0 Install the Software PanelView Component DesignStation 2 0 can be installed on computers running Windows XP SP3 only Windows Vista or Windows 7 For better performance your computer should have at least an Intel Pentium M 1400 MHz processor with 512MB RAM Ensure that you install NET framework 3 5 before installing the software Your computer information can be found by right clicking My Computer and then selecting properties Follow these steps to install the software components 1 2 Click Next to continue the installation or Cancel to cancel installation 120 Insert the CD or go to the web site to install the components The initial splash screen announces that the installer is running It identifies the product being installed Panel iew Component DesignStation 2 0 InstallShield Wizard Preparing to Install Panelview Component DesignStation v2 0 Setup is preparing the InstallShield Wizard which will quide you through
41. Information on page 50 for instructions on how to view the current firmware version Firmwa re Installation Using The terminal can install firmware from a removable storage device Removable Storage Device 76 either a USB flash drive or an SD storage card The firmware consists of an Autorun executable and firmware images that is downloaded from the PanelView Component technical support website http Aab com eoi eraphicterminals panelviewcomponent html The firmware installation starts when the storage device is inserted either while the terminal is running or when the terminal is powered on During the firmware installation you can upgrade or downgrade one ot more of these firmware images e Windows CE Operating System e Application e Communication e Asian font Chinese or Korean The terminal has a firmware partition that accommodates one uset installable Asian font A Simsun Chinese font is factory installed Firmware images for the Simsun Chinese font and Gulim Korean font are on the CD that ships with the terminal and can be downloaded from the technical support website TIP The currently installed Asian font firmware image Is visible in the list of Configuration Languages on the Main Screen Publication 2711C UMO01F EN P November 2010 Publication 2711C UMO001F EN P November 2010 ATTENTION IMPORTANT Upgrade Firmware Chapter 5 Removing the USB flash drive or SD card from the PanelView Compon
42. N P November 2010 Removing the USB flash drive or SD card from the PanelView Component terminal while a firmware upgrade is in process could corrupt the firmware and make the terminal unusable Take precautions to prevent the USB flash drive or SD card from being accidentally disconnected Also do not power off the terminal while a firmware upgrade is in progress ATTENTION USB hubs can produce unexpected behaviors and as a result are not recommended USB Device Port You must connect the PanelView USB device port to a USB host that is connected to the same ground system This port can be used for connecting to a computer to transfer applications fonts and images IMPORTANT Before connecting your computer to the USB port of the PanelView Component terminal you must first install the Allen Bradley PanelView USB remote NDIS Network Device driver on your computer The USB RNDIS driver is only supported on Windows XP and Windows Vista operating systems It is not supported by the Windows 2000 operating system IMPORTANT Install the USB Driver Follow these steps to install the USB driver on your computet 1 Browse the Accessory CD and open the USB Driver folder File Edit View Favorites Tools Help ay QBak O BD sede Folders ily v EJ co Name Size Type Date Modified Location Files Currently on the CD J Write these files to CD Adobe Reader 8 File Folder 1 17 2008 7 18 PM
43. N P November 2010 63 Chapter4 Cable Connections and Communication USB Ports 64 RS 422 RS 485 Port The RS 422 RS 485 port is a nonisolated port that supports point to point communication RS 422 RS 485 Connector Pinout Pin Signal 1 2 T 3 4 R 59 Shield The RS422 485 port has integrated 121 ohm termination between the R and R signal pair This value is compatible with RS422 and RS485 electrical specifications Additional termination on the PanelView Component end of communication cables is not required The terminals have a USB device and USB host port USB Host Port You can power USB peripherals directly from the PanelView component terminal If the USB peripheral is not powered directly from the PanelView USB port either e install the USB peripheral in the same enclosure as the PanelView terminal and make sure it is connected to the same ground system e connect to the USB peripheral through a galvanically isolated hub You can use the USB host port to connect a USB Flash drive to transfer application files fonts and images Some USB flash drives might not be compatible with the PanelView Component terminal and might not support file transfers or firmware upgrades The 2711C RCSD memory card Is tested with the PanelView Component terminal to ensure compatibility Publication 2711C UM001F EN P November 2010 Cable Connections and Communication Chapter 4 Publication 2711C UMO001F E
44. NDIS Network Device Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for Allen Bradley PanelView USB Remote NDIS Network Device Click Finish to close the wizard Finish Driver Installation Note for Windows 7 and Windows Vista 1 During the initial installation of the USB RNDIS boot loader driver you may see the dialog box reporting an unsuccessful installation as shown here B Driver Software Installation ExT Device driver software was not successfully installed Please consult with your device manufacturer for assistance getting this device installed Allen Bradley PanelView Boot Loader USB Device unplugged Remote NDIS Network Device If so ignore this dialog box and click Close to continue installing the driver for Windows 73 Chapter 4 Cable Connections and Communication 74 2 After the driver installation is complete you may see a dialog box similar to the one shown here Device driver software was not successfully installed Please consult with your device manufacturer for assistance getting this device installed Allen Bradley PanelView Boot Loader USB Device unplugged Remote NDIS Network Device Allen Bradley PanelView USB Remote NDIS Ready to use Network Device Close Cycle power to the terminal and reconnect the USB cable 3 This dialog box appears E 57 Device Software Installation Window
45. PanelView Component HMI Terminals User Manual Catalog Numbers 2711C F2M 2711C K2M 2711C T3M 2711C K3M 2711C T6M 2711C T6C 2711C TO6T 2711C T10C Rockwell ALLEN BRADLEY e ROCKWELL SOFTWARE Automation Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment Safety Guidelines for the Application Installation and Maintenance of Solid State Controls publication SGI 1 1 available from your local Rockwell Automation sales office or online at http literature rockwellautomation com describes some important differences between solid state equipment and hard wired electromechanical devices Because of this difference and also because of the wide variety of uses for solid state equipment all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable In no event will Rockwell Automation Inc be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment The examples and diagrams in this manual are included solely for illustrative purposes Because of the many variables and requirements associated with any particular installation Rockwell Automation Inc cannot assume responsibility or lability for actual use based on the examples and diagrams No patent liability is assumed by Rockwell Automation Inc with respect to use o
46. Param2 value S 0 Param3 external tag as its write tag Is within the range of a tag validation should provide a warning if the range of the tag Is greater than the range of a numeric entry Make sure that the values of the state based objects that write to an external tag are within the range of the tag Make sure that the value that written to an external tag matches the tag type for example do not write a non numeric string into a numeric tag Alert 2059 Failed setting property S 0 Param1 S 0 Verify the range of the numeric display that uses the Param2 S 0 Param3 value S 0 external tag as its write tag Is within the range of a Param4 tag validation should provide a warning if the range of the tag Is greater than the range of a numeric entry Make sure that the values of the state based objects that write to an external tag are within the range of the tag Make sure that the value that written to an external tag matches the tag type for example do not write a non numeric string into a numeric tag Alert 2060 Terminal is running low on RAM Please reset the terminal or this may lead to fatal Available RAM bytes error Alert Out of memory Terminal cannot continue to run This is aout of memory critical message Dismissing and will be reset this dialog causes the terminal to reset After the terminal resets try to edit an application and reduce Its size by removing some objects for ex
47. Publication 2711C UM001F EN P November 2010 How to Display Help Publication 2711C UMO001F EN P November 2010 Overview Chapter 1 PanelView Explorer software provides extensive help for the design environment Context sensitive help is available for e cach navigation tab e cach object in the object palette e any dialog that has a Help button Click the on the application toolbar to view the help No Help Files Found To view help information in your browser you must copy the help files from the WebHelp folder of the CD that ships with your terminal to external media and then insert the media 1n the terminal External media can be a USB flash drive or an SD memory card Terminal Users Copy the help files to the WebHelp folder off the root directory of the SD memory card or USB flash drive into a folder named NWebHelp Emulator Users Copy the help files to the WebHelp folder in the shared directory of the emulator for example C Documents and Settings All Users Shared Documents Allen Bradley PanelView Component Emulator WebHelp View Help Files After copying the help files to external media and inserting the media in the terminal you can view the help files by closing this help window and clicking the help button again When receiving updated help files you may have to clear cache in your browser before the new help files display View the PanelView Explorer online Help for detailed Instruction
48. S 0 Param5 P4 S 0 Param6 P5 S 0 Param7 P6 S 0 Param8 Reboot the terminal Contact technical support providing this data ID1 S 0 Param1 ID2 S 0 Param2 Reboot the terminal Verify you have good communication to the controller Verify that the communication network cable is connected If new ladder logic is downloading to the controller you could see this message After the download communication should run normally If a remote device not responding alert is present then all external tags being written to will generate this alert Is the address configured in the controller If the address is configured as read only at the controller this address can not be written to Set this external tag as read and remove panel devices from your application that can write data to this external tag Verify you have good communication to the controller Verify that the communication network cable is connected If new ladder logic is downloading to the controller you could see this message After the download communication should run normally If a remote device not respondingalert was present then all external tags being read from will generate this alert Is the address configured in the controller If the address is configured as write only at the controller this address can not be read from Set this external tag as write and remove panel devices from your application that can read data from th
49. UMO001F EN P November 2010 Configure the Terminal for USB Connection Follow these steps to configure your terminal to be connected through a USB port to a computer 1 Connect the USB host port on the computer to the USB device port on the terminal IMPORTANT The terminal should be directly connected to a USB port on the computer Do not connect through some other device such as a USB port on a monitor keyboard or laptop computer docking station 2 Power up the terminal When the terminal connects to the computer for the first time the new USB device the PanelView Component terminal 1s discovered by the Windows Found New Hardware Wizard that guides you through the installation There are two instances of the driver There is one for the Boot Loader and one for the Windows CE Operating System The USB IP address is always 169 254 254 2 Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Read our privacy policy Can Windows connect to Windows Update to search for software O Yes this time only Yes now and every time connect a device Click Next to continue cee 69 Chapter 4 Cable Connections and Communication 70 3 Choose Install the software automatically and click next Found New H
50. actions are required by the PanelView Component Emulator Installer The only emulator main menu item you may need to use is Flash Save Select Flash Save to preserve settings for the next time the emulator is started such as after copying fonts or User Defined Objects into the emulator The other menu items on the main menu do not apply to the PanelView Component emulator Erik Allen Bradley PanelView C300 Flash Save Virtual PC Component The directory layout for the Virtual PC is defined by the Microsoft installer for this component No additional actions are required by the PanelView Component Emulator Installer Publication 2711C UMO01F EN P November 2010 PanelView Component Emulator Appendix C PanelView Component Emulator Component The root install location for the PanelView Component Emulator component is C Program Files VAllen Bradley The directory structure under the root location is shown Root Location Directory Structure E y My Computer E Set RAWXP F1 C ClearCase dell E3 Docs li c3 Documents and Settings 1386 C Lotus C midi O mvfslags C ORAWIN3Z E Program Files 7 Adobe Adstream E Allen Bradley 3 E PanelView Component Emulator 1 20 C 2711C F2M Lj 2711C K2M 9 2711C k3M O 2711C T3M C 2711C T amp C E 2711C T6M C 2711C T10C The install directory under the root is named PanelView Component Emulator This folder contains the script files re
51. ample user controls screens tags or alarms Alert 2055 Cannot copy recipe to a loaded application Please unload application and try again Alert 3001 Available memory is too low to run the Please try to release some memory or this may lead application to fatal error Multilanguage 8193 Language switch ignored Application was not Either add the specified language and associated configured with new language An attempt was strings or remove the unconfigured language made to switch to a language that is not selection configured for this application Publication 2711C UMO001F EN P November 2010 89 Chapter6 Troubleshoot the System Troubleshooting 90 If your terminal does not start up correctly check for adequate power observe the splash screen state message and status code indicator states or an application that is not running during powerup Determine what changed since the last time the terminal ran normally and decide if the change can be reversed Check for Adequate Power A terminal that does not receive adequate power could cause unpredictable behavior Verify the power requirements in the Specifications table Observe Splash Screen Various actions and status conditions of the terminal are reported on the splash screen including version information about the hardware and firmware State Hardware Message Version Ci Aes firarlay Boot Loader Status or Error Version Code Firmwa
52. ard slot only TTITAEUEE nalog touch screens are intended for single presses at a time If the touch screen is pressed in two locations at the same time the presses are averaged as a single press in between the two locations The terminals can be connected to a browser using either a USB port ot an Ethernet network connection Your computer should have at least an Intel Pentium M 1400 MHz processor with 512 MB RAM You must enter the IP address of the PanelView Component terminal into the address field of your browser You can find the IP address on the terminal configuration screen under Communications Publication 2711C UMO01F EN P November 2010 Publication 2711C UMO001F EN P November 2010 Overview Chapter 1 USB Port The PanelView Component terminals have a USB device port to support communication with the terminal using TCP IP ma before connecting your computer to the USB port of the PanelView Component terminal you must first install the Allen Bradley PanelView USB remote NDIS Network Device driver on your computer Refer to Install the USB Driver on page 65 With the USB device port connected to a computer use your computet s browser to connect to the terminal The IP address of the USB port is always 169 254 254 2 Tititetae ine USB device port is for maintenance or programming only and is not intended for normal run time operation Ethernet Port The C600 and C1000 terminals have an E
53. ardware Wizard This wizard helps you install software for Allen Bradley PanelView Boot Loader USB Remote NDIS Network Device If your hardware came with an installation CD lt 6 or floppy disk insert it now What do you want the wizard to do Install from a list or specific location Advanced Click Next to continue he wizatd searches for the files Found New Hardware Wizard Please wait while the wizard searches Ba Allen Bradley PanelView Boot Loader USB Remote NDIS Network Device Cancel 4 If the Windows Logo Test warning dialog box is displayed click Continue Anyway Hardware Installation The software you are installing for this hardware Allen Bradley PanelView Boot Loader USB Remote NDIS Network Device has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing STOP Installation Publication 2711C UMO01F EN P November 2010 Cable Connections and Communication Chapter 4 Publication 2711C UMO001F EN P November 2010 The software installs Found New Hardware Wizard Please wait while the wizard installs the
54. are faults Publication 2711C UMO001F EN P November 2010 91 Chapter6 Troubleshoot the System Returning to the Out of box Condition 92 At startup the Fault indicator is off except for a few brief flashes and the Comm indicator is on If the indicators remain off check the power cable After a successful startup both indicators are off and controlled by the application running on the terminal The table shows indicator states if the terminal stops during startup Fault Indicator States During Startup Comm Recommended Action Green Indicator State Fault Red Indicator State Description Potentially recoverable errors Blinking Off Last firmware download Reload the firmware failed Blinking Blinking EBC boot loader Reload the firmware firmware failed or is missing Blinking On Windows CE OS Reload the firmware firmware failed or is missing Nonrecoverable or fatal errors On Off Fatal hardware error Replace the terminal On Blinking Fatal display hardware Replace the terminal error You may want to return a terminal to the out of box condition to refresh the terminal or to recover from severe application misbehavior There is a special maintenance action that permits you to perform a complete reset and return to the out of box condition for the terminal Returning a terminal to an out of box condition does not affect the terminal firmware version or the installed font image Fol
55. asked if you want the mapped share folder removed 5 Click Yes or No on the Remove Share folder dialog Question Remove the Emulator mapped Share directory The directory C Documents and Settings All Users Documents Allen Bradley P c Emulator Is no longer being used Delete this directory and its contents Make note of this directory location if you plan to reinstall the emulator at a later date If you choose this same Share directory when reinstalling the emulator all your current files will be automatically available If you answer yes the folder and all its contents are deleted If you wish to preserve its contents answer no TIP By default the application files you create are stored in this folder If you wish to preserve the applications that you created answer no for the folder to remain on the computer 6 Follow the uninstall process for the Microsoft Device Emulator Microsoft Loopback Adapter and Virtual PC files from your computer if necessary The Microsoft Device Emulator Microsoft Loopback Adapter and Virtual PC could be used by other software packages 111 Appendix C PanelView Component Emulator Directory Layout and Content 112 This section describes where you can find the files that the installer loaded on yout computet Device Emulator Component The directory layout for the Device Emulator is defined by the Microsoft installer for this component No additional
56. bar that reads Image sent Check Terminal for reboot completion 8 The terminal reboots and automatically performs the requested Operations during startup 9 Check that the terminal reverts to the startup application 134 Publication 2711C UMO01F EN P November 2010 Firmware Update Utility Appendix E Resolve Firmware Upgrade If you experience problems with the firmware update utility check Issues that your USB RNDIS adapter settings are correct 1 Open the Windows Network Connections folder 2 Reset the Terminal Momentarily open the USB connection at the same time TIP power is cycled Otherwise the power from the USB connection may prevent the terminal from resetting 3 Right click the connection with name Allen Bradley PanelView Boot Loader USB Remote RNDIS Network Device when it appears then select Properties Note that this connection will disappear after a few seconds ac n Hetwork Connections File Edit View Favorites Tools Advanced Help a J Is Ej r O 7 d F Search p Folders b 4 X if Address e Network Connections v Mame Type Status Device Mame Phone or Dial up b MLIS Dial Dial up Disconnected Conexant HDA 0110 MDC v 92 Modem 65571090 LAN or High Speed Internet Oe Wireless Network Connection or High Speed Inter isable eli Wireless ini Car P wireless Network Connect LAN or High Speed Int Disabled Del
57. cation Free 39 686 144 Refer to View System Information on page 50 for instructions on how to view the current firmware version 79 Chapter 5 Notes 80 Upgrade Firmware Publication 2711C UM001F EN P November 2010 Chapter 6 Troubleshoot the System Chapter Objectives This chapter provides information on how to isolate and correct common operating problems with system components e View system information e Alerts e Troubleshooting View System Info rmation You can view current system information for the connected terminal You should provide this information when contacting technical suppott e Operating system version e Firmware version e Hardware version number e Status of the battery e Total power on time e Memory used in KBytes Follow these steps to view the system information on your terminal 1 Go to the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the System Information tab 4 View the information 5 Click Apply Alerts The terminal displays alerts at times during operation The alert consists of an ID number and a description Follow the corrective action to resolve the alert Publication 2711C UMO01F EN P November 2010 81 Chapter 6 Troubleshoot the System PanelView Component Terminal Alerts Data Access Error for Alias S 0 Param2 Controller S 0 Param3 Address is S 0 Param4 Communication Flag is S 0 Param1 Cat
58. ck start publication 27116 05001 A file transfer operation requires you to enter a source location file type and destination location e Source location the location of the file you want to transfer You can transfer a file from Internal Storage of the terminal USB Storage SD Storage or My Computer 52 Publication 2711C UMO01F EN P November 2010 Transferring Applications Publication 2711C UMO001F EN P November 2010 Configuration Mode Chapter 2 e Source File Type the type of file you want to transfer The types of files you can transfer include PanelView Component applications images user defined objects fonts recipes and the terminal security file Destination location The location where you want to transfer the selected file You can transfer a file to Internal Storage of the terminal USB Storage SD Storage or My Computet If transferring a file from or to USB or SD storage verify that the USB flash drive or SD card is inserted in the terminal before starting the file transfer Applications created on one PanelView Component terminal can be used on other PanelView Component terminals For example you might design an application on one terminal and then distribute the application to other terminals for production Transferring an application is a two step process e Export the application from the internal storage of the terminal to your computer a USB Flash Drive or SD card Import
59. clicking the Terminal Settings link on the PanelView Explorer Startup window you can access tabs to adjust the display brightness and contrast configure screen saver settings configure key repeat settings calibrate the touch screen if supported reset the terminal view system information change the startup application change the terminal language change the current date and time Ethernet communication change the passwotd of the system administrator Most of these settings are also adjusted from configuration mode on the terminal AB PanelView Component QUALITY Terminal Settings File Transfer Help Sign Off oe Status Applications Name Initial T10C Location Internal Mode Running DisplayAnput System Information Communication Terminal Security Display Input Devices Brightness 100 Cl Enable key repeat 00 Color Key Repeat Rate 0 Terminal via Ethernet Contrast 50 Key Repeat Delay 375 Screen saver mode _ Enable Screen Saver and Dimmer Reboot Terminal Screen Save aput Calibrate Touch Screen 1 minute Screen saver brightness 5 X Et 24 Publication 2711C UMO01F EN P November 2010 Publication 2711C UMO001F EN P November 2010 Configuration Mode Chapter 2 Select a Terminal Language You can change the terminal display language The terminal is shipped with the E
60. e IMPORTANT If the application list is empty the run copy delete and set as Startup functions will not perform any action Follow these steps to select or change the startup application using the PanelView Explorer Startup window 1 Go to the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the System Information tab 4 Select the name of the startup application from the Startup Application pull down list AB PanelView Component QUALITY Dashboard File Transfer Help Sign Off LA Displayinput System Information Communication Terminal Security Firmware version 01 10 Current Date R Month Day Year Boot Code version 01 10 August v z7 v 2008 vj Logic Board version IU D Gurren Time Battery status Good Hour Minute Second ls wii33 vil v Terminal on time minutes 35250 8 sa 33 06 v Memory used 36 HE Automatically adjust for daylight savings time Time zone GMT 08 00 Pacific Time US amp Canada Startup Application Initial T10C v Terminal Language English v English Portugu s Fran ais Italiano Deutsch Espa ol fitta 50 5 Click Apply or click Cancel to restore the current setting Publication 2711C UM001F EN P November 2010 39 Chapter 2 Configuration Mode Follow these steps to select or change the startup application from the C600 or C1000 terminal 1 C
61. e Connections and Communication Chapter 4 The C600 and C1000 terminals have an Ethernet port that supports e communication to a controller e connection to a computer for application design Ethernet Connector The base configured unit of the terminals has an RJ45 10 100 Base T connector for Ethernet network communication Ethernet Connector Pinout Pin Pin Name Looking into RJ45 TD Connector 1 8 TD RD Z C2 Z Z J O olJ Shield Connection Chassis Gnd C Hither a standard Ethernet cable ot a crossover cables such as 2711P CBL EX04 can be used when connecting directly to a logic controller or switch Cables The PanelView Component terminals require category 5 twisted pair cables The maximum cable length between the terminal s Ethernet port and a 10 100 Base T port on an Ethernet hub without repeaters ot fiber is 100 m 328 ft In industrial applications keep the cable length to a minimum For additional information refer to the EtherNet IP Media Planning and Installation Manual publication ENET IN001 61 Chapter4 Cable Connections and Communication Security Considerations IGMP Internet Group Management Protocol is used for IPv4 multicast A multicast is communication between a single sender and multiple recetvers on a network IGMP is used to exchange membership status data between IPv4 routers that support multicasting and member
62. e Exit 8 Press F4 to exit to the main menu 41 Chapter 2 42 Configuration Mode Change the Date and Time You can adjust the current date and time for terminal operations The time is set in 24 hour format You can also set the terminal to automatically adjust the time for daylight savings time Follow these steps to change the terminal date and time using the PanelView Explorer Startup window 1 Go to the PanelView Explorer Startup window Click the Terminal Settings link Click the System Information tab Update the Current date fields Update the Current time fields Check Automatically adjust for daylight savings time if you want the terminal to adjust for daylight savings time Click Apply or click Cancel to restore the current terminal settings AB PanelView Component QUALITY Dashboard File Transfer Help Sign Off Displayinput System Information Communication Terminal Security Firmware version o 10 Current Date Month Day Year Boot Code version 01 10 August R 27 J 2008 3 Logic Board version i RET UE Battery status Good Hour Minute Second Terminal on time minutes fms 8 33 x 06 x Memory used LN Automatically adjust for daylight savings time Time zone GMT 08 00 Pacific Time US amp Canada Startup Application Initial T10C v Terminal Language English v English
63. e is Admin The new password takes effect the next time the terminal 1s restarted As long as security is enabled any user that tries to access the terminal or the design time environment while connected to the terminal must first log in with a valid user name and password The terminal also secures itself when idle If terminal input is not received within the idle timeout period the user is logged out The user must log in again to access the terminal The default terminal idle timeout is 30 minutes IMPORTANT store your password in a safe place If you forget the password you will not be able to connect to the design environment Chapter2 Configuration Mode Follow these steps to secure the design environment 1 Go to the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the Terminal Security tab 4 Check Terminal Security Enabled PanelView Component Dashboard File Transfer Help Sign Off Displaynput System Information Communication Terminal Security Terminal Security C Terminal Security Enabled Terminal User Terminal User Name Admin Reset Terminal User Password Terminal Timeout Terminal Idle Timeout 30 minutes Y English Portugu s Fran ais ttaliano Deutsch Espa ol fiic 5 Optionally enter a new Terminal User Name 6 Click the Reset Terminal User Password button Publication 2711C UMO01F EN P November 2010
64. e previous dialog 3 Accept the license agreement and click Next to continue with the 4 Click Install to continue with the installation Cancel to cancel the The verification screen gives you a chance to cancel the installation process before any permanent changes occur ji Panel iew Component DesignStation v2 0 Ready to Install the Program The wizard is ready to begin installation Panel iew Component DesignStation 2 0 will be installed to C Program Files Allen Bradley Click Install to begin the installation If you want to review or change any of your installation settings click Back Click Cancel to exit the wizard The installation process may take several minutes to complete InstallShi Cancel 121 Appendix D PanelView Component DesignStation 2 0 The progress screen gives you a visual indication of the installation progress iz Panel iew Component DesignStation 2 0 Installing Panel iew Component DesignStation 2 0 The program features you selected are being installed Please wait while the InstallShield Wizard installs Panel iew Component DesignStation 2 0 This may take several minutes Status Updating component registration InstallShi 5 Click Finish to complete the installation The install complete screen is the final confirmation that the install has completed successfully is Panel iew Comp
65. eferred to as the Mapped Share folder The default location for this mapped share folder is shown zi y My Computer E s RAWXP F1 GCs ClearCase 3 dell C Docs 3 i Documents and Settings Administrator i All Users Application Data C Desktop i Favorites i C Shared Documents H O Adobe PDF i3 Allen Bradley gt ERES Component Emulator However the installer allows the user to optionally select a different location for this shared folder There are two primary ways to launch the PanelView Component emulator The first is via entries in the Windows Start Menu The second is via double clicking a PanelView Component user application file cha Publication 2711C UMO01F EN P November 2010 PanelView Component Emulator Appendix C Windows Start Menu The PanelView Component Emulator installer creates entries in the Windows Start Menu that can be used to launch a specific emulated terminal type There is also a shortcut named Applications which is simply a shortcut to the Mapped Share folder The shortcuts are installed for all users Usi ng the Emulator The emulator lets you create applications without being connected to a terminal By default anytime you create save an application on emulator it goes to the mapped share folder TIP When using the emulator to create or change applications make sure your pop up blocker is off Anything you pull into internal storage on the emulator
66. egory Communication Communication Communication Communication Communication Communication 82 T 3 4 9 The terminal is having trouble reading the external tag at this controller and address Communication Server Error Communication Server Error Communication Server Error Communication Server Error Communication Server Error Check that the communication network cable is connected If new ladder logic is downloading to the controller you could see this message After the download communication should run normally Verify you have good communication to the controller If a remote device not responding alert was present then all external tags being actively scanned will generate this alert Is the address configured in the controller If so make sure all addresses of external tags to this controller are configured at the controller If one address is outside of the range a block of addreses might show this condition If the address is configured as write only at the controller this address cannot be read Set this external tag as write only and remove panel devices from your application that want to display data from this external tag Contact technical support providing this data ID1 S 0 Param1 ID2 S 0 Param2 P1 S 0 Param3 Reboot the terminal Contact technical support providing this data ID1 S 0 Param1 ID2 8 0 Param2 P1 S 0 Param3 P2 S 0 Param4
67. en calibration is only supported on touch only terminals catalog numbers 2711C I3M 2711C T6C 2711C 16T 2711 T6M and 2711 1100 Follow these steps to calibrate the touch screen using the Panel View Explorer Startup window 1 Go to the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the Display Input tab 4 Click Calibrate Touch Screen PanelView Component Dashboard File Transfer Help Sign Off DisplayInput System Information Communication Terminal Security Display Input Devices Brightness 100 C Enable key repeat m 7 7 Key Repeat Rate Exe el Contrast 50 s E pd Key Repeat Delay Enable Screen Saver and Dimmer M Reboot Terminal ALAPA RAYENUNEOUNS Calibrate Touch Screen 1 minute Screen saver brightness 5 Refresh TN amet e 5 With a stylus press the center of the target on the screen Publication 2711C UMO01F EN P November 2010 Configuration Mode Chapter 2 Publication 2711C UMO001F EN P November 2010 6 Repeat step 5 as the target moves around the screen 7 Tap the screen when prompted to register saved data If you don t tap the screen within 30 seconds the calibration data is lost and the current settings are retained Follow these steps to calibrate the touch screen from the terminal 1 Click Display on the menu list 2 For C600 and C1000 terminals click Calibrate Touchscreen Brightn
68. ent terminal while a firmware upgrade is in process could corrupt the firmware and make the terminal unusable Take precautions to prevent the USB flash drive or SD card from being accidentally disconnected Also do not power off the terminal while a firmware upgrade Is in progress or during the subsequent boot up process that follows the firmware upgrade USB hubs can produce unexpected behaviors and as a result are not recommended some USB flash drives might not be compatible with the PanelView Component terminal and might not support file transfers or firmware upgrades The catalog number 2711C RCSD memory card was tested with the PanelView Component terminal to ensure compatibility Only the C600 and C1000 support the SD Storage Card he firmware version consists of a major and minor two digit number and a three digit revision number separated by a period for example 01 23 456 where 01 is the major 23 is the minor and 456 is the revision The firmware version for the terminal is displayed on the System Information screen he firmware version information appears in the filename of the firmware file that is downloaded from the PanelView Component technical support website for example 2711C FUP 01 23 EXE After upgrading your firmware you should clear your browser cache To clear cache in the Firefox browser select Tools gt Clear Private Data Verify the Cache checkbox is checked and click the Clear Private data b
69. epe ar Rl d ed did 17 CODHoUratiote ITHEeFITGES Soc Coe bet oer tad eeu ees 20 J etnia SENO Soo wes ta ea nd b Sel B dip UR ub Use es ote eased 22 Managing Applications and DMess cea vi ox ue e boa a 52 JTeanstertrino JXDDICAHOFTIS 625 4598 qud o Ur esce o E eae bete Rd 55 Malidatethe JApDHOXHOT s 2 ua dea RS eee doe 3 1d d odi dn 55 Transferring User defined Objects 4 0244 2000 HORT RR EE VES 56 Chapter 3 Ghapter DIOC Ves eua db E tau ees e AEN ed Ue edo 57 DIIMOTHOR Cadere aea a a edis UR hacen s ae 57 USB TASTI Vesir ettan aah E amt aed a oe dee 57 Battery Replacement 524 008 catet ee qnos E ER PR RUE QUOS ror 58 Chapter 4 Chapter OBIeCtly6Sctiag iet ht Vu vaa esses epa C qtii qd 59 Wirino and Safety Guidelines x 2 ce inte Rte doe eU FO c e eni ds 59 CoOnnectine Devices Au ssepe E a E oe ET OaE 60 MicroLogix Controller Cable CHAfts o 22d tori o ote saa 60 Eterne Contiec HOD c aos ps3 he aoe AERE A ur READ RETE 61 Oe COD CHONS 4095 0 ace oe BR Ind i ed uA EU E 63 IU SB OU Sete ae st eu Bet ees Siok datus arg ar RUE QU Wok sape oda es ua pra t Ad 64 Table of Contents Upgrade Firmware Troubleshoot the System Specifications Adding Font Files PanelView Component Emulator PanelView Component DesignStation 2 0 Chapter 5 Chapter ObieCivesoss eicere ie boh aub P Ead bri UR seats 75 Prepare Tor Fitmwate D DpStade Je veedoes exp iseia oie ek es T9 Firmware Installation Using Removable Storage Device 76
70. er bitmaps and recipes You can also delete applications from terminal storage and export the alarm history log Displays help for the PanelView Explorer startup window and the design time software 4 sign off Logs you off the Startup window leaving your browser open 5 Terminal Type and Status shows the current connection between your PanelView Component terminal and computer and the type of terminal 6 Language shows the current and available languages for the design time software 7 Create New Application Opens a new application in the design time environment window Se ZI LA 5 Publication 2711C UM001F EN P November 2010 21 Chapter 2 Configuration Mode PanelView Explorer Startup Window Item 8 9 10 Description Edit Test Run Use these buttons to edit test and run the currently loaded application Available Applications Shows a list of applications stored on the terminal USB memory SD card or PC Storage on the emulator The list also shows if the file has been validated for correct operation Stop Click the Stop button the stop sign shown when an app is loaded and in Edit Test Run mode to unload the currently loaded application If you have not saved changes to the application you are prompted to do so Once the application is unloaded the terminal displays the Configuration screen Terminal Settings Terminal settings can be set on the terminal or through the PanelView 22 Explorer Startup window
71. error detail information is required This is the error code The remaining two pieces are optional and their content varies according to the error code PVcEmClick Error Codes 0x10001 0 emdags mdangss Invalid command line 0x10002 Missing CHA file name path command argument NEN A CHA file name path argument ends in a lt name path gt CHA file name path does not contain path info 0x10003 0 lt keyname gt Emulator info not found registry 0x10005 0 lt erreode gt Error reading CHA file header Invalid CHA file header content 0x1000A a Failed calling launch script PVcEmLaunch Error Codes 0x20001 0 lt cmdargs Invalid command line 0x20003 C L a Emulator root not found registry lt keyname gt No matching emulator version found in registry lt version gt Best fit invalid version number format lt err Eccc ME Best fit failed enumerating installed versions Low Best fit no best fit found No TitleBar found in emulator skin XML file 0x20007 PY The emulator is already running 0x20008 err Unable to enumerate emulator registry parameters 0x20004 0x20006 0x20009 lt keyname gt Base emulator command string not found in registry Error constructing emulator command string lt keyname gt Base web browser command string not found in registry Error constructing web browser command string Publication 2711C UMO001F EN P November 2010 117 Appendix C
72. erstand this manual or operate the terminal Equipment installers must be familiar with standard panel installation techniques For additional information on the PanelView Component terminals refer to these publications that you can download from http literature tockwellautomation com Resource Description PanelView Component Terminal Installation Provides instructions for installing a Instructions publication 2711C INO01 PanelView Component terminal PanelView Component Operator Terminals Provides instructions on setting up a sample Quick Start publication 27116 05001 application on a PanelView Component terminal If you would like a manual you can e download a free electronic version from the Internet at http literature rockwellautomation com e purchase a printed manual by contacting your local Allen Bradley distributor or Rockwell Automation sales office Preface Preface Firmware Upgrades To receive firmware upgrades and other downloads for your PanelView Component terminal e call your local Rockwell Automation sales office or distributor access http ab com eoi eraphicterminals panelviewcomponent html 10 Publication 2711C UMO01F EN P November 2010 Chapter Objectives About the Terminals Publication 2711C UMO01F EN P November 2010 Chapter 1 Overview This chapter gives an overview of the PanelView component terminals e About the terminals e How to connect browser e PanelVie
73. es all files including user applications Cleaning the registry only removes registry settings such as the user s selected startup application but will not remove user applications from the terminal 1 Connect the USB host port of your computer to the USB device port on the terminal 2 From the Start Menu select Programs gt Allen Bradley gt PanelView Component Firmware Update Utility 3 When the utility is running make sure Clean File System Clean Registry ot both are checked When you check Clean File System Clean Registry is automatically checked because the registry is a file 4 Click the Browse button to select an SC image for example SC 01 01 002 IMG The SC image is typically obtained from the PanelView Component technical support website When a valid SC image is opened the version information is extracted and displayed Publication 2711C UMO001F EN P November 2010 133 Appendix E Firmware Update Utility 5 Click the Begin Waiting for Connect Requests button to send the selected operations to the terminal when requested C TempiSt 01 01 002 1h 2 Started fstening for BOOTHE requests on port 380 The utility is waiting for an update request from the terminal 6 Reset the terminal Momentarily open the USB connection at the same time TIP power is cycled Otherwise the power from the USB connection may prevent the terminal from resetting 7 Wait until you see the message on the progress
74. es to restart the terminal Alert 2018 File already exists Overwrite If you do not want to overwrite the file cancel the operation and rename the file beforeperforming this operation Alert 2019 Cannot copy over loaded application Unload Click OK to unload and overwrite the application application and continue with overwrite Alert 2020 Cannot copy over loaded application Unload application and try again Alert 2021 Insufficient space to complete file copy Remove files to free space from the destination and try again Alert 2022 Source and destination cannot be the same Verify the source and destination are not the same and retry Alert 2023 Application has been left in edit or test mode Reconnect the designer or press OK to proceed to the configuration screens Alert 2024 File not found Recipe 2025 Copy failed Only existing recipe files can be Create the recipe through the designer or rename updated this recipe to the existing recipe name and try again Recipe 2026 Copy failed Invalid recipe file The imported recipe must have the same number of ingredients and data sets as the existing recipe it is replacing Alarm 202 Alarm logs can only be copied from a loaded Load the application into Edit lest or Run mode and application retry Alert 2028 Files can only be copied to a secured application The application has been secured with design while editing the application rights Load the applicati
75. ess Tauchscreen Contrast 3 For C300 touch screen terminals press the right arrow to go to the calibration screen D Allen Bradley PanelView C300 C Anen Bradley Pane View C300 Alfen Hradiey Panel View Cag Startup Application Display Calibrate Touch Sereen be Display ee ran S E HE Z 4 Carefully press and briefly hold stylus on the center of the target Repeat as the target moves around the screen alen Bradley PanelView C1000 pe Aien Hradiey Paru View CO 35 Chapter2 Configuration Mode 5 Click OK within 30 seconds once the message appears to accept the changes or the old settings are kept Reboot the Terminal You can restart the terminal without having to disconnect and reapply power After a reset the terminal performs a series of startup tests and then either enters configuration mode or runs the startup application Follow these steps to reboot the terminal from the PanelView Explorer Startup window 1 Go to the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the Display Input tab 4 Click Reboot Terminal button NB QUALITY PanelView Component Dashboard File Transfer Help Sign Off Displavinput System information Communication J Screen saver mode Enable Screen Saver and Dimmer v Screen saver timeout lminute Screen saver brightness b _ Terminal Security Display
76. f information circuits equipment or software described in this manual Reproduction of the contents of this manual in whole or in part without written permission of Rockwell Automation Inc is prohibited Throughout this manual when necessary we use notes to make you awate of safety considerations Identifies information about practices or circumstances that can cause an explosion in a hazardous environment which may lead to personal injury or death property damage or economic loss IMPORTANT Identifies information that is critical for successful application and understanding of the product Identifies information about practices or circumstances that can lead to personal injury or death property damage or economic loss Attentions help you identify a hazard avoid a hazard and recognize the consequence ATTENTION STH awa Labels may be on or inside the equipment for example a drive or motor to alert people that dangerous voltage may be present PTT neva Labels may be on or inside the equipment for example a drive or motor to alert people that Surfaces may reach dangerous temperatures o A AN A A Rockwell Automation Allen Bradley TechConnect PanelView PanelView Component and MicroLogix are trademarks of Rockwell Automation Inc Trademarks not belonging to Rockwell Automation are property of their respective companies Summary of Changes The information below summarizes the changes to this man
77. fonts graphics has to be Flash Saved for it to be permanently stored in emulator Otherwise it s lost once you shut down To save to internal storage select Flash and then Save from the Emulator s main window menu On the emulator do not change terminal communication settings otherwise you need to uninstall and install the emulator and the data will be lost Follow defaults when installing the emulator it sets up the file structure TIP For more information on working with the emulator refer to the context sensitive help Publication 2711C UMO001F EN P November 2010 115 Appendix C 116 PanelView Component Emulator IP addresses for your emulator The following is a list of IP addresses to use with your emulator IP Addresses for Emulators Terminal Catalog Number 2711C T10C 2711C T6T 2711C T6M 2711C T6C 2711C 13M 2711C K3M 2711C K2M 2711C F2M IP Address 169 254 253 9 169 254 253 10 169 254 253 8 169 254 253 7 169 254 253 6 169 254 253 5 169 254 253 4 169 254 253 3 Publication 2711C UM001F EN P November 2010 PanelView Component Emulator Appendix C Error Codes There are a variety of failure conditions that can occur in the emulator browser launch process The launch mechanism contains a popup dialog to report errors to the user To avoid multi language issues the error reporting dialog simply contains a title bar and up to three pieces of error detail information The first piece of this
78. ialog In the Save As dialog accept the default file name and cha file type and click Save or enter another path Click Close when the download is complete Import an Application During an import the cha application file is transferred from a USB Flash Drive SD card ot computer to the internal storage of the terminal The transfer operation communicates with the terminal to import the file You cannot overwrite an application while the application is running You must unload the current application before overwriting the application You can import applications while another is running Follow these steps to import an application 1 25 Go to the PanelView Explorer Startup window If an application is currently loaded click the stop sign above the dashboard to unload the current application Click the File Transfer link Click New Transfer Select the source location of the application and click Next Select Application as the file type and click Next Click Browse to locate the cha file you want to import Select Internal Storage as the destination and click Transfer Publication 2711C UM001F EN P November 2010 Validate the Application Publication 2711C UMO001F EN P November 2010 Configuration Mode Chapter 2 The application is transferred to the internal storage of the terminal If an application with the same name already exists in internal storage you will be asked if you want to rep
79. ication 2711C UM001F EN P November 2010 45 Chapter 2 Configuration Mode Follow these steps to set the IP address for the Ethernet port of the connected terminal from the C600 and C1000 terminals 1 Click Communication from the menu list 2 Click Set Static IP Address Communication Protocol iu Status Unavailable Device Name PVeen T l IP Mode Static IP Address Mask Gateway Enable DHCP Set Static IP Address ETE The Static IP Address screen appears Static IP Address IP Address Gateway 46 Publication 2711C UMO01F EN P November 2010 Publication 2711C UMO001F EN P November 2010 Configuration Mode Chapter 2 3 Click on the area next to IP Address to enter an IP address in the Static IP address field A keypad displays to let you enter the address 4 Enter the subnet mask in the Static Subnet mask field 5 Enter the default gateway in the Static Default gateway field Ema s fa TIAL LEI LLL shit z x c v b nimp Lil pujwinee Po 4 ee ateway Enable Terminal Security Use terminal security to restrict user access to the terminal configuration screens and the PanelView Explorer Startup window For example you can require users to enter a user name and password before accessing or editing an application Initially the terminal and the PanelView Explorer Startup window are unsecured To enable security provide a password The default user nam
80. inching packages from Microsoft You yal be prompted bo begin he instalation of each package and then returned to the Panettew Component Emulator vazard The installabon process wall tala several mnubes to complete The progress screen gives you a visual indication of the installation progress TTITAECEMS ne Microsoft Device Emulator and Microsoft Virtual PC have their own installation procedure and agreements Once they are installed if you selected complete install or selected them for custom install you will be brought back to the finish dialog ie PanelView Co mponent Emulator v1 0 Installing PanelView Component Emulator v1 The program Features you selected are baing installed z Fasza mak whia thes Tricia Shedd Wiad inct as Paneles Component Emulator v1 0 This may Lake several mnubes Brabus 106 Publication 2711C UMO01F EN P November 2010 PanelView Component Emulator Appendix C 7 Click Finish to complete the installation The install complete screen is the final confirmation that the install has completed successfully It should be displayed only after all selected components have completed installation ie PanelView Component Emulator v1 0 mmm j i EE Installshield Wizard Completert The Iretalisteeld Wizaed has successfully installed Panef esa I E miistor vi Cirk Finish to edi tha strand PanelView Component Extended Support This is a Rockwell Automation provided accessory for the Pa
81. is external tag 83 Chapter6 Troubleshoot the System PanelView Component Terminal Alerts Communication 2 Remote Device S 0 Param1 is Not Verify all network connections are correct Responding Verify that the communication network cable is connected If new ladder logic is downloading to the controller you could see this message After the download communication should run normally Verify that the network address of the controller matches the terminal controller address configured in the Communication tab In the Communication tab verify that the protocol specifications are correct such as communication rate data bits stop bits These are all protocol specific Communication Invalid Data Address S 0 Param1 This is not syntactically a valid address Communication 30 Bad address in block S 0 Param1 to S 0 This can occur when a write only address for a Param2 on device S 0 Param3 controller has been set for read write in the external tag of the terminal Param1 to Param2 specifies the address block having the issue Somewhere within the range is where the write only address is defined in a PanelView external tag Set the external tag to write Recipe 1001 Recipe upload started This message is for informational purposes No corrective action needed Recipe 1002 Recipe save failed Cause Recipe in Table has not Make sure that the recipe table is modified before been modified the save operati
82. l Wireless 1390 WLAN Mini Card ila Local Area Connection LON or High Speed Inter Connected Broadcom Netxtreme 57xx Gigabit Controller zl MS Loopback LAN or High Speed Inter Connected Microsoft Loopback Adapter 2 8 Local Area Connection 12 LAN or High Speed Inter Disabled Allen Bradley Panelview Boot Loader USB Remote MOIS M Wizard Allen Bradley Panelview Boot Loader USB Remote NDIS Network Device ss Mew Connection Wizard Wizard NEN Publication 2711C UMO001F EN P November 2010 135 Appendix E Firmware Update Utility 4 Select Advanced Windows Firewall Protect my computer and network by limiting or preventing access to this computer fram the Internet Internet Connection Sharing Allow other network users to connect through this computer s Internet connection Home networking connection LV MERI ECC CIC MCI Rr A Select a private network connection adl LIII Learn more about Internet Connection Sharing qe i General Exceptions Advanced Windows Firewall helps protect your computer by preventing unauthorized users from gaining access to your computer through the Internet or a network 9 This setting blacks all outside sources from connecting to this computer with the exception of those selected an the Exceptions tab Select this when you connect to public networks in less secure locations such as airports
83. lace the existing application If the target terminal is a different type and size then the source terminal the application will be converted when in Edit Test Run or Run mode The application may require updates in design mode before running properly Before you can run an application on the PanelView Component it is strongly recommended that you validate the application for errors and warnings The application does not need to be error free to run in the application however it is good practice to fix both errors and warnings to ensure expected system behavior 1 Click the Validate icon on the application toolbar If the application passes validation the Validation Results dialog looks like this If the application detects warnings or errors the Validation Results dialog might look like this For each warning or error the message identifies the problem and its location Correct the problem and then revalidate the application The status bar shows a Validation Reports link that you can open It always shows the results of the last validation 2 Click Close 55 Chapter 2 Configuration Mode Ma warning or errors to report SRE oath Err WR Hol P ek ee a tel Close f LI m chat 1 Da Tyes Message A028 Warning Momentary Push Button PushButton does not have a Write Tag defined on Screen MOTOR_STATUS Application has been modified Please remember to save your application oO a non validated
84. lick File Manager from the Main menu Current Application File Manager Config Language Date and Time Espa ol ota 0 Year Second System Information Reset Terminal Communication nglish D ay Hour Portugues a Fran ais i z opens Italiana inut Display US aa Deutsch 2 Select the location of the application from the Source list either Internal USB or SD File Manager Source T D nitial TEC Copy Set As Startup 3 Select the name of the startup application from the Name list 4 Click Set As Startup 40 Publication 2711C UMO01F EN P November 2010 Configuration Mode Chapter 2 Publication 2711C UMO001F EN P November 2010 Follow these steps to select ot change the startup application from the C200 or C300 terminal 1 Click Startup Application from the Main menu C Allen Bradley PanelView C200 P Carmmunicatian E p P Startup Application v l 2 Press F1 to reset the startup application 0 ANen Bradiay Panel View C200 4 Press F4 to exit to the main menu 4 Click on File Manager from the main menu 5 Press F1 to select the source either internal or USB Allen Bradley PanelView C200 6 Press F3 to go to the list of applications and use the arrows to select the startup application D ANen Bradley PanelView C200 T i pnt al FzM i Dt F2 F4Ext F3 gt D Alfen Bradley PanelView C200 gt Set Startup mu F F
85. low these steps to return your terminal to the out of box condition 1 Connect an external USB keyboard to the terminal and hold the Ctrl and Shift keys simultaneously while starting up the terminal A dialog box appears with the prompt Return to Out of Box Condition Publication 2711C UM001F EN P November 2010 Publication 2711C UMO001F EN P November 2010 Troubleshoot the System Chapter 6 TTTIATUEo lt eyboards initialize at different times If the terminal boots normally to the configuration screen or the selected startup application the keyboard press was not recognized Restart the terminal and wait until the boot screen displays the INIT code N1 then press and hold the Ctrl and Shift keys until the dialog box appears 2 Press Yes ot F1 to return to the out of box condition or press No or F2 to cancel If you choose to return to the out of box condition the terminal resets On the subsequent boot the file system 1s formatted and removes the contents including applications logs recipes user installed fonts objects and graphics Most terminal configuration parameters are returned to their default values Returning to the out of box condition does not change the current firmware on your termnal If you upgraded the firmware on your terminal the upgraded firmware version remains unaffected Refer to page 76 for details on what is included in a firmware upgrade IMPORTANT If you set the terminal securi
86. lowing five components If you select Full Install all five of these components are installed If you select Custom Install you have the option of selecting which of these components are installed Microsoft Device Emulator Microsoft Virtual PC Microsoft Loopback adapter PanelView Component Emulator Extended support files fonts demos graphics help 103 Appendix C PanelView Component Emulator Follow these steps to install the emulator components 1 Insert CD or go to web site to install emulator components The InstallShield Wizard appears InstallShield Wizard ij Panelview Component Emulator v1 0 Setup is preparing the A InstallShield Wizard which will guide you through the program setup process Please wait Extracting PanelView Component Emulator 1 0 msi The initial splash screen announces that the installer is running It identifies the product being installed 2 Click Next to continue the installation or Cancel to cancel installation if PanelView Component Emulator v1 0 Welcome to the bnstallhield Wizard for Panehiew Component Emulator v1 0 The Irest ase Ri cand wil intial Pansies Component Emulator v1 0 cn your computer To continuis cik Nast WARNING Thes program ik protected bry copyright Lavy and international beasties 3 Accept the license agreement and click Next to continue with the emulator installation z lS FanelYiew Component Emulator v1 0 License Agree
87. m Information eminal On Time 51 Chapter 2 Configuration Mode Follow these steps to view system information using the C600 or C1000 PanelView Component terminal 1 Click System Information from the menu list The system information screen displays firmware version boot code version logic board version terminal on time display on time and battery status System Information Firmware Version 01 30 0086 Boot Code Version 00 00 Logic Board Version 10 Terminal Qn Time 90 Display On Time O Battery Status Not Available Memory Usage bytes Internal Used 1 804 288 Internal Free 19 079 168 Application Used 9 379 840 pplication Free 39 686 144 Managing Appl ications and The PanelView Explorer Startup window has a File Transfer link for Fil es transferring files to and from terminal storage media File names and tag names should start with an alpha character Avoid starting names with numeric ot special characters From the File Transfer view you can export or import applications user defined objects images the terminal secutity file recipes and fonts import screensaver bitmap files expott the alarm log from the currently running application delete applications user defined objects images font files terminal user file and recipes from terminal storage TIP For more information on creating applications and transferring files see PanelView Component Operator Terminals Qui
88. ment Pins raed tha Following Kara agreement carefully END USER LICENSE AGREEMENT FOR COMPLIMENTARY SOFTWARE IMPOETAMT READ CAREFULLY This End User License a Agreement Agreement is a legal contract between you Licensee or you and Rockwell Automation Inc Licensor for the software product entitled PanelView Component Emulator the Softwnre which is ring provided by Licensor to Licensee on a complimentary basis in AS IS condition for Licensee s internal use The So twnre includes all installed mme rme cma am memo moe 0m mm maram doo W amm fade Im mme 9 accept the terme in the Bcenza agreement m O1 de nct accept tha berms in tha canoe agreement 104 Publication 2711C UMO01F EN P November 2010 PanelView Component Emulator Appendix C Publication 2711C UMO001F EN P November 2010 4 Select the installation type You can select between Complete Express or Custom installation Complete installs all components at the default installation locations and with all default user options Custom causes the installer to bring up a dialog that allows you to customize the installation process Express only installs the PanelView Component Emulator Use Express install for upgrading the firmware of the emulator im PanelView Component Emulator v1 0 Setup Type Choose hha setup hype thak b st c gb your eads Pisassa celect a seti Hypa usi All program features wall be irstalled
89. n registry 133 computer requirements 12 configuration interfaces 20 PanelView explorer startup window 21 terminal 20 configuration mode 17 access 1 design time 18 runtime 19 connect a browser 12 Ethernet 13 USB ports 13 connect devices 60 Publication 2711C UMO01F EN P November 2010 Index date and time 42 C600 and C1000 43 PanelView explorer window 42 design time 18 operating systems 18 supported browsers 18 DesignStation browser support 119 DesignStation directory layout and content 124 DesignStation installation requirements 120 DesignStation software installation 120 DesignStation software uninstallation 123 display help 15 E emulator 103 custom setup 105 directory layout and content 112 124 emulator use 115 117 initial splash screen 104 120 107 122 103 120 108 105 122 launch mechanism 114 124 115 125 104 121 mapped share folder 114 overview 103 119 progress screen 106 uninstall 110 107 verify install 106 enable terminal security 4 Ethernet 13 cables 61 44 61 PanelView explorer window 45 security considerations 62 46 export applications 53 F firmware install from storage device 78 prepare for upgrade 75 78 upgrade 75 10 76 fonts adding 99 import 99 remove 100 H how to connect a browser 12 139 Index 140 display help 15 IGMP Protocol 62 Import applications 54 import font 99 install battery 58 SD memory card 57 USB flash drive 57 install and replace
90. ndow 2 Click the Terminal Settings link 3 Click the Display Input tab 4 Check Enable key repeat to enable repeat settings for keys PanelView Component Dashboard File Transfer Help Sign Off DisplayInput System Information Communication Terminal Security Display Input Devices Brightness 1 00 Cl Enable key repeat M A Key Repeat Rate L Contrast 50 S rl Key Repeat Delay J Enable Screen Saver and Dimmer j Reboot Terminal BEER EHVBCUIHOOUS Calibrate Touch Screen Tminute w Screen saver brightness 5 C M MM M Refresh ENTM e a 5 Drag the slider under Key Repeat Rate to adjust the speed at which a character repeats when a key is held down 6 Drag the slider under Key Repeat Delay to set the amount of time that elapses before a character begins to repeat when the key is held down 7 Click Apply or click Cancel to restore the current settings To disable key repeat settings uncheck Enable key repeat Publication 2711C UMO001F EN P November 2010 33 Chapter 2 34 Configuration Mode Calibrate the Touch Screen Over time you may notice that the objects and images on the display screen don t seem to fit the display area as well as they once did This is normal with a touch screen and can be easily fixed Use a plastic stylus device with a minimum tip radius of 1 mm 0 040 in to prevent damage to the touch screen Touch scre
91. nelView Component emulator This component consists of extended help files sample applications libraries and font files These files were originally installed in the Mapped Share folder Note multiple versions of the PanelView Component Emulator could be using the same Mapped Share folder During uninstallation of the PanelView Component Emulator a check is made to see if the Mapped Share folder is being used by any other versions of the emulator If other versions are using the same Mapped Share folder this step is skipped entirely If the PanelView Component Emulator version being uninstalled is the only version using this Mapped Share folder the uninstaller will ask if you want to remove the extended support files If you select Yes the files are deleted and the Mapped Share folder 1s removed If you select No this step is skipped and the files and directory remain Publication 2711C UMO001F EN P November 2010 107 Appendix C PanelView Component Emulator Errors During Installation If an error is reported while configuring the Loopback Adapter make sure the Loopback Adapter settings are correct Follow these steps to configure the Loopback Adapter settings 1 Open the Windows Network Connections folder and right click the connection with device name Microsoft Loopback Adapter Name Type Status Device Name LAN or High Speed Internet ab Local Area Connection LAN or High Speed Internet Connected Broadcom Netxtreme
92. nelView Component Designstation 2 0 to create or change applications make sure your pop up blocker is off For more information on working with PanelView Component TIP DesignStation 2 0 refer to the context sensitive help Publication 2711C UMO001F EN P November 2010 125 Appendix D PanelView Component DesignStation 2 0 Notes 126 Publication 2711C UM001F EN P November 2010 Chapter Objectives About the Utility Publication 2711C UMO001F EN P November 2010 Appendix E Firmware Update Utility This appendix shows how to use the PanelView Component Firmware Update Utility to perform recovery and maintenance operations on a PanelView Component terminal that is in a non operating state IMPORTANT Use the utility described in this appendix only if the terminal is not operable Always use the firmware upgrade described in Chapter 5 when you want to upgrade firmware to an operating terminal and functioning operating system TIP The PanelView Component Firmware Update Utility is a PC application that interacts with the Boot Loader on the terminal via a USB connection to perform maintenance actions on the terminal firmware The utility supports a firmware maintenance capability that is independent of the operating system and or the other firmware elements on the terminal Use the utility only to recover from fatal conditions e A non functioning operating system that resulted from a failed ot interrupted
93. nelView Component Firmware Update Utility on your computer WARNING This computer program is protected by copyright law and international treaties Unauthorized duplication or distribution of this program or any portion of it may result in severe civil or criminal penalties and will be prosecuted to the maximum extent possible under the law Cancel 2 Click Next m Panel iew Component Firmware Update Utility Select Installation Folder The installer will install Panelview Component Firmware Update Utility to the following folder Ta install in this folder click Next Ta install ta a different folder enter it below or click Browse Folder C Program Files Allen Bradley Paneliew Component Firmware Upde Browse Disk Cost Install Panelview Component Firmware Update Utility for yourself ar for anyone who uses this computer Evenone C Just me You have the option of clicking Browse to change the folder location and to install the utility for anyone who uses this computer or the person currently logged on 3 Click Next to install the utility to the folder location 129 Appendix E Firmware Update Utility Update Firmware 130 m PanelView Component Firmware Update Utility Confirm Installation The installer is ready to install Panelview Component Firmware Update Utility an your computer Click Next to start the installation Cancel Back
94. nglish Portuguese French Italian German Spanish and Chinese fonts installed Korean is available but you must first install the Korean font Refer to page 76 for information on how to install the font by upgrading the firmware Follow these steps to change the terminal language using the PanelView Explorer Startup window 1 Go to the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the System Information tab 4 Selecta language from the Terminal Language pull down list PanelView Component Dashboard File Transfer Help Sign Off Display ynput System Information CO muc aton T Termin i al Security Firmware version hy 10 Current Date Month Day Year Boot Code version 01 10 August v 27 3 2008 z Logic Board version i D urrenit time Battery status Good Hour Minute Second Terminal on time minutes 95250 s 33 os wj Memory used 96 a Automatically adjust for daylight savings time ere Time zone Startup Application GMT 08 00 Pacific Time US amp Canada Initial T10C vj Terminal Language English v 5 Click Apply or click Cancel to restore the current setting 25 Chapter 2 Configuration Mode On the C600 and C1000 terminals the default language is set on the Main menu Just click the up and down arrows to select the language Current Application Config Language File Manager Communication Portugu s Fran ais
95. nk 3 Click the System Information tab AB PanelView Component QUALITY Dashboard File Transfer Help Sign Off DisplayInput j System Information Communication Terminal Security Firmware version 01 10 Current Date Month Day Year Boot Code version 01 10 Anauet vl z v 2008 v Logic Board version io UE E Battery status Good Hour Minute Second Terminal on time minutes 525020 8 33 06 vj Memory used 36 m ClAutomatically adjust for daylight savings time en Time zone SR RUEEAGIBRCSUON GMT 08 00 Pacific Time US amp Canada Initial T10C x Terminal Language English v English Portugu s Fran ais Mallno Deutsch Espa ol f ffcPxt 30 50 Publication 2711C UMO01F EN P November 2010 Configuration Mode Chapter 2 Publication 2711C UMO001F EN P November 2010 Follow these steps to view system information using the C200 or C300 PanelView Component terminal 1 Select System Information from the menu list and press enter Allen Bradley Panel View C300 Screen Saver b System Information Reset Terminal The system information appears 2 Press F3 to see more information press F2 to go back or press F4 to exit to the main menu Q Allen Bradley PanelView C300 Q Allen Bradley PanelView C300 System Information Allen Bradley PanelView C300 Allen Bradley PanelView C300 Syste
96. nnot be altered Additional Windows CE licensed fonts can be added to the terminal Windows CE licensed fonts are distributed on the PanelView Component Accessory CD ot can be downloaded from the PanelView Component Tech Support website No other fonts are licensed for use on the terminal Set up Fonts for Ensure that you install a NET framework before setting up fonts PanelView Component Copy the fonts files to this folder c Program Files V Allen Bradley PanelView DesignStation 2 0 Component DesignStation Fonts Launch PVcDesignStation 2 0 to finish setting up the fonts Import a Fo nt FI le You can import a Microsoft Windows CE font to your terminal Other font files are not supported During the import the font file is transferred from a USB Flash Drive or SD card to the internal storage of the terminal The transfer operation communicates with the terminal to transfer the file You can use the imported font in any application on the terminal TIP Fonts cannot be exported for copyright reasons Follow these steps to add a font to the terminal 1 Open the PanelView Explorer Startup window Publication 2711C UMO001F EN P November 2010 99 Appendix B Adding Font Files Remove a Font File 100 Click File Transfer Click New Transfer Select the source location of the Font file typically My Computer and click Next Select Font as the file type and click Next Click Browse to locate and select the Fon
97. nput tab 4 Select a screen saver mode from the list AB PanelView Component QUALITY Dashboard File Transfer Help Sign Off DisplayInput System Information Communication Terminal Security Display Input Devices Brightness 1 00 Cl Enable key repeat S 7 Key Repeat Rate Contrast 50 77 j Key Repeat Delay 9 Screen saver mode Rc Enable Screen Saver and Dimmer v Reboot Terminal Screen saver imeat Calibrate Touch Screen 1 minute vi Screen saver brightness 5 C 29 Chapter 2 Configuration Mode 5 Select a time from the pull down list to adjust the screen saver timeout 6 Drag the slider to adjust the screen saver brightness 7 Click Apply or click Cancel to restore the current screen saver settings To disable the screen saver or dimmers select Disable Screen Saver and Dimmer from the screen saver mode list Follow these steps to configure the screen saver from the C600 and C1000 terminals 1 Click Display on the menu list 2 Select the Mode Mode Image Disable Dimmer Image and Dimmer 3 Select the brightness Brightness 1 100 increments of 1 4 Select the idle time Choices are 1 2 5 10 15 20 30 or 60 min Brightness aes Contrast va Touchscreen ij Brightness Timeout 30 Publication 2711C UM001F EN P November 2010 Configuration Mode Chapter 2 Publication 2711C UMO001F EN P November 2
98. ode of your PanelView component terminal Configuration mode Configuration interfaces Terminal settings Managing applications and files Transferring applications Transferring user defined objects The terminal can be configured from either the design time or the runtime user interface The design time user interface requires a computer browser connected to the terminal s web service where the runtime user interface uses configuration screens on the terminal The configuration data for a terminal refers to the collection of all of the system interface parameters Access to the Terminal s Configuration Running Internet Explorer or Firefox browser E USB or Ethernet connectivity On Terminal Configuration Publication 2711C UMO01F EN P November 2010 17 Chapter 2 Supported Browsers and Platforms Configuration Mode Operating System Windows 7 Windows Vista Windows XP SP2 18 Design time Configuration The design time configuration is when the terminal is actually hosting web server content that represents a visualization of the terminal s properties and files You can only design for the terminal type that you are connected to When a new application is created the design time automatically navigates to the first screen and assigns it as the startup screen The design time environment is compatible with these operating systems e Windows 2000 catalog numbers 2711C T6M 2711C T6C 27
99. on the same computet W Add or Remeve Programs a M4 Curienity Friik pr F1 Show updates zot bry Hara an Change or Marcial elus eC TOT Ta 3 X pec 5 Ert Privar m u Pheer iets Wirken bauri Varese ose J 628 Hri a Dipa curse yz Ss 2I ira MORAL 4 0 587 ce Tun Se A Progr ams rom a D sk deai iAd Se hip EE ene cheni Pantin v0 20RA Ses LOE i Pansies E rinm Enmulat or wii SN csi ris amaa Tih ern Le parcere arm fren yeu compe chk Hoch e l Power 5 7 Hes LAMB Set Progen y QuickTime See ANPE Aie aed Delauks jl hapresty Purper Erin Hee LE Bi 555 socurID Software Token Se SHE y Same Tee 3 0 RAZ We DL TMB iB sor Portal Shortcut BAZ us UIME E TAPDI SAT Patch 25 Frot End RAA 23 Click Remove 4 Click Yes to confirm that you want to remove the PanelView Component Emulator Add or Remove Programs 2 Are you sure you want to remove Panelview Component Emulator v1 0 From your computer Publication 2711C UMO01F EN P November 2010 PanelView Component Emulator Appendix C Publication 2711C UMO001F EN P November 2010 The computer goes through the removal process and shows a progress scteen PanelView Component Emulator v1 O fen Please wait while Windows configures PaneMView Component Emulator v1 Gathering required information Se DoS n en H DOSE Reem Cancel After the last version of Panel View Component Emulator is uninstalled you ate
100. on into Edit mode and retry Alert 2029 Files can only be copied from a secured The application has been secured with design application while editing the application rights Load the application into Edit mode and retry Alert 2030 Cannot delete a loaded application Unload application and try again Alert 2031 Files can only be deleted from a secured The application has been secured with design application while editing the application rights Load the application into Edit mode and retry Alert 2032 Return to out of box condition Press Yes to reboot the terminal and return to the out of box condition Alert 2033 Source file does not exist Make sure the source file exists and retry Publication 2711C UMO001F EN P November 2010 87 Chapter6 Troubleshoot the System PanelView Component Terminal Alerts Alert 2034 Destination folder does not exist Make sure the destination location exists and retry Alert 2035 Insufficient disk space Please free disk space and Remove files to free space by pressing the Delete try again File button on the File Transfer tab Alert 2036 This application is not validated Are you sure you Press Yes to continue running the invalid want to run a non validated application application or No to proceed to the configuration screens Then edit and validate the application Correct all validation errors save the application and try again Alert 2038 Cannot change password because
101. on is done Recipe 1003 Recipe save had errors This message is for informational purposes No corrective action needed Recipe 1004 Recipe save completed successfully This message is for informational purposes No corrective action needed Recipe 1005 Recipe download failed Cause Operation This message is for informational purposes No cancelled corrective action needed Recipe 1006 Recipe download started This message is for informational purposes No corrective action needed Recipe 1007 Recipe download completed with errors This message is for informational purposes No corrective action needed Recipe 1008 Recipe download completed successfully This message is for informational purposes No corrective action needed 84 Publication 2711C UM001F EN P November 2010 Troubleshoot the System Chapter 6 PanelView Component Terminal Alerts Recipe 1009 Recipe Download failed Cause Unable to write Check for to S 0 Param1 Communication errors Bad data point specification The ingredient value written is outside the Low EU and High EU limits of the numeric data point assigned These are optional OPC defined properties representing data point minimum and maximum values The ingredient value could notbe converted to the type of the data point assigned Recipe 1010 Recipe upload completed with errors This message is for informational purposes No corrective action needed Recipe 1011 Recipe
102. onent DesignStation 2 0 InstallShield Wizard Completed The InstallShield Wizard has successfully installed PanelView Component DesignStation v2 0 Click Finish to exit the wizard 122 Publication 2711C UMO01F EN P November 2010 PanelView Component DesignStation 2 0 Appendix D Uninstall the Software Publication 2711C UMO001F EN P November 2010 The PVc DesignStation Software removes all registry settings files directories and Windows Start menu items that were originally installed with this component Follow these steps to uninstall the components 1 Go to the Control Panel under the Windows Start Menu 2 Select Add or Remove Programs and highlight PanelView Component DesignStation 2 0 i Add or Remove Programs EN mj x es Currently installed programs Show updates Sort by Name Change or MF erosurc OTT TAME NAR 2 0 Jervice Far Size Tes UOrie T Remove Programs js Microsoft NET Framework 3 0 Service Pack 2 Size 169 00MB js Microsoft NET Framework 3 5 SP1 Size 28 23MB fy Ca Microsoft Office Professional Plus 2007 Size 271 00MB Add New Programs Mozilla Firefox 3 6 12 Size 31 24MB m m Add Remove Windows EX Oracle32 Forms 4 5 RA2 Size 36 32MB Components js MSXML 4 0 SP2 KB954430 Size 2 67MB 5 MSXML 6 0 Parser Size 1 46MB UE Panel iew Component DesignStation 2 0 ri Click here For support information Set P
103. our file then click Next Select Screen Saver Image as the file type then click Next Locate where you saved your bitmap file on your computer or external storage device Select Internal Storage as file destination then click Transfer The bitmap file is successfully transferred to the PVc terminal File Transfer Wizard From My Computer File To i Select file type to transfer Di Application q User Defined Object Image Al Font 22 Terminal User e Recipe Screen Saver Image The new screen saver takes affect the next time the screen saver is activated 32 TIP Your bitmap file should be small in size A large bitmap will impact performance of terminal operations Publication 2711C UMO01F EN P November 2010 Configuration Mode Chapter 2 Configure Key Repeat Settings You can configure key repeat settings for the terminal keys or attached keyboard of the connected terminal TIP You cannot change the key repeat settings from the on terminal configuration screens If you want to change this setting you must connect to the terminal through a web browser The repeat rate is the speed at which a character repeats per second when you hold down a key The repeat delay is the amount of time in milliseconds that elapses before a character begins to repeat when you hold down a key Follow these steps to change the repeat settings for keys l Go to the PanelView Explorer Startup wi
104. presentative or visit http www rockwellautomation com support Installation Assistance If you experience a problem within the first 24 hours of installation review the information that is contained in this manual You can contact Customer Support for initial help in getting your product up and running United States or Canada 1 440 646 3434 Outside United States or Use the Worldwide Locator at http www rockwellautomation com support americas phone_en html or contact Canada your local Rockwell Automation representative New Product Satisfaction Return Rockwell Automation tests all of its products to ensure that they are fully operational when shipped from the manufacturing facility However if your product is not functioning and needs to be returned follow these procedures United States Contact your distributor You must provide a Customer Support case number call the phone number above to obtain one to your distributor to complete the return process Outside United States Please contact your local Rockwell Automation representative for the return procedure Documentation Feedback Your comments will help us serve your documentation needs better If you have any suggestions on how to improve this document complete this form publication RA DU002 available at http www rockwellautomation com literature Rockwell Otomasyon Ticaret A S Kar Plaza Is Merkezi E Blok Kat 6 34752 erenk y Istanbul Tel 90 216 5698400
105. quired for launching the emulator Under the PanelView Component Emulator directory is the directory named HH where is the major and minor version number of the emulator This format allows later versions of the emulator to be installed without disrupting previous installations Publication 2711C UMO001F EN P November 2010 Emulator Versions 3 Allen Bradley A azz11c F2M 3 C Panelview Component Emulator I 711C K2M o 2711c K3M 3 711C F2M 92711C T3M C 2711C K2M 9 2711C Tac C 2711C K3M D 2711C T6M 3 2711C T3M 9 2711C T10c 3 2711C T6c E PvcEmul bin C 2711C T6M 3 2711C T10C 113 Appendix C PanelView Component Emulator Launch Mechanism 114 There is a subdirectory for each terminal type The subdirectory name is the catalog number for the respective terminal type These subdirectories contain the files that define each emulated terminal image and behavior The files making up the emulator contain the base name of the terminal catalog Terminal Subdirectory 3 Allen Bradley A 27110 T10C xml E PanelView Component Emulator g 2711C T10C Down bmp E 1 20 SN 2711C T10C Mask bmp 5 2711C F2M S 2711C T10C_Up bmp C 2711C k2M O 2711C K3M C 2711C T3M C 2711C T amp C C 2711C T6M 2er11c TIi UC Mapped Share Folder The emulator is launched with the command line option that maps a PC folder into the emulator s file system The given computer folder is r
106. r connection perform these operations P erowse CiTempisC 01 01 002 IMG Browse ps ra l Started isbenima for BOOTME requests on port 5 80 The utility always requires a companion firmware image SC XX XX IMG even if you are only performing a clean file system or clean registry operation The utility is on the CD that is shipped with your terminal and the firmware image is downloaded from the website http Aab com eoi eraphicterminals panelviewcomponent html The utility requires that you connect the USB host port of your computer to the USB device port on the terminal IMPORTANT Before connecting your computer to the USB port of the PanelView Component terminal you must first install the Allen Bradley PanelView USB remote NDIS Network Device driver on your computer Refer to Install the USB Driver on page 65 128 Publication 2711C UMO01F EN P November 2010 Firmware Update Utility Appendix E Install the Utility Publication 2711C UMO001F EN P November 2010 The firmware update utility is on the CD that ships with your computer Follow these steps to install the firmware update utility on your computer 1 Double click PVcFwUpSetup in the Firmware Firmware Utility folder on the CD ie Panel iew Component Firmware Update Utility Welcome to the PanelView Component Firmware Update Utility Setup Wizard The installer will quide you through the steps required to install Pa
107. re Progress Bar Version These tables describe the state messages and the status or error codes that appear on the splash screen Power on Self test POST Failures Message State Code POST Failed RAM 6C POST Stuck Key 31 POST Stuck Touch 3A Publication 2711C UMO01F EN P November 2010 Troubleshoot the System Chapter 6 Firmware Installation and Loading Message State Code Load Firmware Image into RAM 1E Write Firmware Image into Flash A5 Complete and Successful Firmware Installation OK Firmware Image Validation CRC Format Failure 1E Firmware Image Compatibility Failure 1F Firmware Write to Flash error A5 Firmware Read After Write Verify D2 Invalid or missing Firmware Image 0A Other Commonly Observed Status Codes Message State Code Boot Loader connects to PC via USB Device 0A Boot Loader loads Firmware Image into RAM E6 Boot Loader jumps to Operating System FF Operating System start up GO Operating System Initialize 1 JO Application Registration and Initialize N1 N3 Application Load and Execute N4 N6 POST errors are fatal and most likely due to failed hardware A fatal error during firmware installation and loading is most likely recoverable by installing the appropriate firmware Interpret the Status Indicators at Startup The C600 and C1000 terminals have indicators on the back of the unit to isolate operating problems e Comm indicator for communication e Fault indicator for hardw
108. recipe operation another Recipe operation Recipe 1019 Recipe S 0 Param1 failed Cause No recipe Select recipe and try again selected in Selector c NO c Recipe S 0 Param1 failed Cause Data type Change the type of the ingredient to match the type of data point S 0 Param2 is incompatiblewith of the data point or select a different data point ingredient type of ingredient S 0 Param3 which matches the type of the ingredient Recipe Publication 2711C UMO001F EN P November 2010 85 Chapter 6 Troubleshoot the System PanelView Component Terminal Alerts Category Recipe Recipe Recipe Recipe Recipe Recipe Recipe Alert Alert Alert Alert Alert Alert Alert Alert Alert Alert Alert Alert 86 1021 Recipe S 0 Param1 failed Cause Unable to Check the communication settings and data point read from S 0 Param2 specification 1022 Recipe S 0 Param1 failed Cause Unable to Check the communication settings and data point read from Tag specification 1023 Recipe download failed Cause The value S 0 Correct the dataset value Param1 is greater than the maximum value 8 0 Param2 allowed for ingredient S 0 Param3 1024 Recipe S 0 Param1 failed Cause Table does Restore the recipe in the table before doing a save not contain a recipe operation 1 025 Recipe S 0 Param1 of recipe S 0 Try
109. rogram Access and Defaults To remove this program from your computer click Remove amp PDFCreator RA4 Size r1 Razer Salmosa Size ur RoboSource Control 3 1 Size 34 94MB Roxio Creator DE 10 3 Size 18 07MB BSS RSA SecurID Software Token Size 2 59MB js Sametime Client v3 0 Size Symantec Endpoint Protection Size 4 Click Remove 4 Click Yes to confirm that you want to remove the software Add or Remove Programs X 1 Are you sure you want to remove PanelView Component DesignStation v2 0 From your computer No The computer goes through the removal process and shows a progress screen Panel iew Component DesignStation 2 0 AL Please wait while Windows configures PanelView Component g oF DesignStation v2 0 Gathering required information Cancel 123 Appendix D PanelView Component DesignStation 2 0 Directory Layout and Content Launch Mechanism 124 This section describes where you can find the files that the installer loaded on yout computer PanelView Component DesignStation 2 0 Component The root install location for the Panel View Component DesignStation 2 0 component is C Program Files Allen Bradley The directory structure under the root location is shown Root Location Directory Structure E y My Computer E Set RAWXP 71 C 5 acd4efeaFz486f5c e58455604a899df 72b4U04374eBalab9144400 3 dell C3 Documents and Settings C3 1386 Intel Cj ORAWIN3Z E
110. rogram is protected by copyright law and international treaties j Cancel 4 Click Install to begin the installation of the PanelView USB RNDIS Driver i PanelView USB RNDIS Driver Ready to Install the Program The wizard is ready to begin installation Click Install to begin the installation If you want to review or change any of your installation settings click Back Click Cancel to exit the wizard InstallShield Publication 2711C UMO01F EN P November 2010 Cable Connections and Communication Chapter 4 The progress indicator shows that the driver is installing i PanelView USB RNDIS Driver Installing Panel iew USB RNDIS Driver The program Features you selected are being installed Ld Please wait while the InstallShield Wizard installs Panelview USB RNDIS Driver This may take several minutes Status Installshield 5 Click Next when the Device Driver Installation Wizard dialog box appears Device Driver Installation Wizard Welcome to the Device Driver Installation Wizard This wizard helps you install the software drivers that some computers devices need in order to work To continue click Next Cancel The drivers install Device Driver Installation Wizard The drivers are now installing Please wait while the drivers install This may take some time to complete Cancel Publication 2711C UMO001F EN P November 2010 67 Chapter 4 68
111. s 15 Chapter 1 Overview Peripheral Connection Catalog Number Configuration 16 PanelView Component terminals have a USB host port You can power USB peripherals directly from the Panel View Component terminal If the USB peripheral is not powered directly from the PanelView USB port either e install the USB peripheral in the same enclosure as the PanelView terminal and make sure it is connected to the same ground system e connect to the USB peripheral through a galvanically isolated hub Removing the USB flash drive or SD card from the PanelView Component terminal while a firmware upgrade Is in process could corrupt the firmware and make the terminal unusable Take precautions to prevent the USB flash drive or SD card from being accidentally disconnected Also do not power off the terminal while a firmware upgrade is in progress USB hubs can produce unexpected behaviors and as a result are not recommended These are the available Panel View Component terminals 2711C F2M C200 Function Function keys 2 in Monochrome m p keys 2711C T3M C300 3 in 2711C K3M aoe Numeric and function a oem 2 11C T6M C600 Touch screen 6 in Monochrome 2711C T6C Color STN 2 11C T6T Color TFT ZWICTWC C1000 Color STN Publication 2711C UMO01F EN P November 2010 Chapter Objectives Configuration Mode Chapter 2 Configuration Mode This chapter covers topics that show how to use the Configuration m
112. s of multicast groups A router is an intermediary device on a communication network that expedites message delivery by finding the most efficient route for a message packet within a network or by routing packets from one sub network to another A sub network is a separate part of an organization s network identified through IP addressing PanelView Component terminals provide level 2 full support for IPv4 multicasting IGMP version 2 as described in RFC 1112 and REC 2236 SNMP Simple Network Management Protocol is used for internal network management and is not supported Ports 137 and 138 are normally open to support the NetBIOS protocol used by Windows CE NET similar to other Microsoft and IBM network operating systems 62 Publication 2711C UM001F EN P November 2010 Cable Connections and Communication Chapter 4 Serial Connections The terminals have a multi purpose serial RS 232 port that supports e DH 485 communication through a serial connection e DF1 full duplex communication with controllers using direct connections ot modem connections e third party point to point communication The serial port on the terminal is a 9 pin male RS 232 connector An example with the 1761 CBL PM02 cable is shown here 1T61 CBL PMO Series B Cable ath gcc cn 9 pin D shell Programming Device Conner The maximum cable length for serial communication is 15 24 m 50 ft at 19 2 Kbps Publication 2711C UMO001F E
113. s will now finish installing software from the manufacturer of this device Allen Bradley PanelView Boot Loader USB Remote NDIS Network Device Finish installing software recommended This additional software may be necessary for your device to function properly gt Ask me again later Windows will ask again the next time you plug in your device or log on Cancel 4 Select the Finish installing software recommended option to continue installing the boot loader driver 5 Installation is complete when this dialog box appears Allen Bradley PanelView Boot Loader USB Remote NDIS Network Device installed The software for this device has been successfully installed Allen Bradley PanelView Boot Loader USB Ready to use Remote NDIS Network Device Close Publication 2711C UMO01F EN P November 2010 Chapter Objectives Prepare for Firmware Upgrade Chapter 5 Upgrade Firmware This chapter provides topics on how to upgrade firmware in the terminal e Prepare for firmware upgrade e Upgrade firmware using a removable storage device The firmware upgrade runs an executable script on a removable storage device such as a USB flash drive or an SD card that copies a firmware image into the flash memory of the terminal Follow these steps before a firmware upgrade is started 1 Backup applications and library objects from the terminal 2 Click Stop the stop sign shown when an application 1s loaded
114. screen Allen Bradiey PanelView C200 UE Brightness 28 Publication 2711C UMO01F EN P November 2010 Configuration Mode Chapter 2 Publication 2711C UMO001F EN P November 2010 Configure the Screen Saver You can enable or disable the screen saver on the connected PanelView Component terminal The terminal has four screen saver modes screen saver dimmer screen saver and dimmer or disable e Screen saver activates after the idle timeout elapses using a default scteen saver image The screen saver deactivates when you press a key Dimmer dims the display from full brightness to the brightness level you set when the idle timeout elapses While the display is dimmed you can still see on screen activity When you press a key the display is restored to full brightness e Screen saver and dimmer activates the screen saver and dims the display when the idle timeout elapses Disable screen saver and dimmer keeps the display on The screen saver timeout is the amount of idle time that must elapse before the screen saver dimmer or screen saver and dimmer activates The idle time can be adjusted between 1 60 minutes The brightness intensity of the screen saver or dimmer can be adjusted between 1 100 Follow these steps to configure the screen saver using the Panel View Explorer Startup window 1 Go to the PanelView Explorer Startup window 2 Click the Terminal Settings link 3 Click the Display I
115. settings assigned automatically if your network supports this capability Othenwse you need to ask your network administrator for the appropriate IP settings C Obtain an IP address automatically Use the following IP address IP address 168 254 254 1 Subnet mask 255 255 Default gateway Use the following DNS server addresses Preferred ONS server Alternate ONS server 137 Appendix E Firmware Update Utility Softwa re Maintenance You can display the version information of the PanelView Component Firmware Update utility by clicking the About tab Use the Add or Remove Programs tool in the Control Panel of your computer to install a newer version or repair an existing installation of the PanelView Component Firmware Update utility 138 Publication 2711C UM001F EN P November 2010 A About PanelView Component DesignStation 2 0 119 about the terminals 11 access configuration mode 1 adding fonts 99 additional resources 9 alerts 81 applications export 53 Import 54 transfer 53 applications and files 52 available fonts 99 battery replacement 58 brightness and contrast 26 on terminal 28 PanelView Explorer window 27 C cables charts 60 59 Ethernet 61 calibrate touch screen 34 PanelView explorer window 34 terminal 35 catalog number configuration 16 change startup application 39 C200 and C300 41 40 PanelView explorer window 38 clean file system 133 clea
116. software Hg Allen Bradley PanelView Boot Loader USB Remote NDIS Network Device ae Setting a system restore point and backing up old files in case your system needs to be restored in the future 5 Click Finish in the Completing the Found New Hardware Wizard dialog box for the boot loader Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for Allen Bradley PanelView Boot Loader USB Remote NDIS Network Device Click Finish to close the wizard Finish 6 Click Next when the Found New Hardware Wizard dialog box for the PanelView USB Remote NDIS Network Device appears Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Read our privacy policy Can Windows connect to Windows Update to search for software Yes this time only C Yes now and every time connect a device Click Next to continue 71 Chapter 4 Cable Connections and Communication 72 7 Choose Install the software automatically and click next Found New Hardware Wizard This wizard helps you install software for Allen Bradley PanelView USB Remote NDIS Network Device If your hardware came with an installation CD lt 4 or floppy disk insert it now Wha
117. t do you want the wizard to do Install from a list or specific location Advanced Click Next to continue he wizatd searches for the files Found New Hardware Wizard Please wait while the wizard searches Baj Allen Bradley PanelView USB Remote NDIS Network Device Cancel 8 Ifthe Windows Logo Test warning dialog box is displayed click Continue Anyway Hardware Installation The software you are installing for this hardware Allen Bradley PanelView USB Remote NDIS Network Device has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Publication 2711C UMO01F EN P November 2010 Cable Connections and Communication Chapter 4 Publication 2711C UMO001F EN P November 2010 he software installs Found New Hardware Wizard Please wait while the wizard installs the software Bj Allen Bradley Panelview USB Remote NDIS Network Device AbUsbFuncRndisColnstaller dll To C WINDOWS system32 LLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLIS 9 Click Finish in the Completing the Found New Hardware Wizard dialog box for the PanelView USB Remote
118. t file then click Open Select Internal Storage as the destination for the font file and click Transfer Observe the informational message for Transferring File The terminal should be rebooted to load the added font and make it available to the design environment If importing a font to the emulator internal storage you need to Flash Save for it to be permanently stored in the emulator Otherwise it will be lost once you shut down To save to internal storage select Flash and then Save from the Emulator main window menu A font that was added to the terminal and is no longer used can be removed Follow these steps to remove a font from the terminal 1 pA Open the PanelView Explorer Startup window Click File Transfer Click Delete File Select the source location of the Font file typically Internal Storage and click Next Select Font as the file type and click Next Observe the list of all Font files that have been added to the Terminal Select the Font file that you want to delete and click Delete Observe the Confirmation message for the selected Font file and click OK Observe the informational message Deleting File Publication 2711C UM001F EN P November 2010 Publication 2711C UMO001F EN P November 2010 Adding Font Files Appendix B 9 Observe the deleted font file no longer appears in the list of all Font files 10 Reboot the terminal to remove the file from the design environment ATTENT
119. t supported connection configured in this application Edit the application and configure communication for the supported connection type 2010 his application is not validated Are you sure you If you do not want to run the invalid application want to run a non validated application cancel the operation then edit and validate the application Correct all validation errors save the application and try again 2011 Cannot run a modified application save the application and try again Publication 2711C UM001F EN P November 2010 Troubleshoot the System Chapter 6 PanelView Component Terminal Alerts Alert 2012 Application has been modified Continue without Edit the application and save prior to performing this saving operation otherwise changes to the application may be lost Alert 2013 Currently loaded application has been modified Edit the application and save prior to performing this All changes will be lost by running this operation otherwise changes to the application may application Continue be lost Alert 2014 Application was designed for a different terminal Edit the application on the terminal type that it is type and may not appear or operate as intended intended for Continue Alert 2015 Application will be unloaded and deleted Click Yes to continue with operation Continue Alert 2016 Confirm deletion Click Yes to delete the file Alert 017 Confirm restart Press Y
120. the program setup process Please wait Decompressing Panelview Component DesignStation v2 0 msi EE im PanelView Component DesignStation v2 0 Welcome to the InstallShield Wizard for PanelView Component DesignStation v2 0 The InstallShield R Wizard will install PanelView Component DesignStation v2 0 on your computer To continue click Next WARNING This program is protected by copyright law and international treaties Back Cancel Publication 2711C UMO01F EN P November 2010 PanelView Component DesignStation 2 0 Appendix D Publication 2711C UMO001F EN P November 2010 installation im PanelView Component DesignStation v2 0 License Agreement Please read the following license agreement carefully END USER LICENSE AGREEMENT FOR COMPLIMENTARY SOFTWARE IMPORTANT READ CAREFULLY This End User License Agreement Agreement is a legal contract between you Licensee or you and Rockwell Automation Inc Licensor for the software product entitled PanelView Component DesignStation the Software which is being provided by Licensor to Licensee on a complimentary basis in AS IS condition for Licensee s internal use The Software includes all installed x I accept the terms in the license agreement Print C Ido not accept the terms in the license agreement InstallShi lt Back Cancel installation or Back to go back to th
121. the application from a computer USB Flash Drive or SD card to the internal storage of another terminal If the target terminal is a different type and size than the source terminal some aspects of the application is converted and the remaining properties require updates If trying to run an application you are warned that the application was not created for the terminal but you are given an option to continue or cancel unless the differences make it impossible to run the application for example an Ethernet application on a terminal without an Ethernet network connection PanelView Component applications are saved with a cha file type You cannot edit the file outside of the PanelView Explorer design environment Export an Application During an export the application file is transferred from internal storage of the terminal to a USB Flash Drive SD card or computer The application is saved with its default name and cha file type Follow these steps to export an application 1 Go to the PanelView Explorer Startup window 2 Click the File Transfer link 53 Chapter 2 54 Configuration Mode 10 Click the New transfer button Select Internal Storage as the source location of the application and click Next Select Application as the file type and click Next Select the application you want to export and click Next Select the destination for the application and click Transfer Click Save in the File Download d
122. thernet port The Ethernet port supports both static IP addresses and Dynamic Host Configuration Protocol DHCP assigned IP addresses If using static IP addressing then you manually set the IP address the subnet mask and the default gateway If using DHCP then the server automatically assigns an IP address the subnet mask the default gateway and the DNS and WINS server IMPORTANT If a terminal is set for DHCP and is not on a network or IS on a network that does not have a DHCP server or the server is not available it will automatically assign itself an Automatic Private IP Address or auto IP address The auto IP address will be in the range of 169 254 0 0 through 169 254 255 255 he terminal makes sure the auto IP address is unique from any other auto IP address of other devices on the network The terminal can now communicate with other devices on the network that have IP addresses in the 169 254 xxx xxx range and a subnet mask of 255 255 0 0 13 Chapter 1 Overview PanelView Explorer 14 PanelView Explorer is the design environment for the PanelView Component terminals You access the design environment through yout browser while connected to the terminal Applications created in the design environment are simultaneously viewed on the connected terminal In addition to graphic objects and drawings the design environment provides support for communication tags alarms security recipes and language suppott
123. time TIP power is cycled Otherwise the power from the USB connection may prevent the terminal from resetting Publication 2711C UMO001F EN P November 2010 131 Appendix E Firmware Update Utility 7 Observe the progress bar and the Details window for status information as the images are downloaded to the terminal While the image is downloading the terminal displays UPDATE 1E on its splash screen 8 Wait until you see the message on the progress bar that reads Image sent Check Terminal for reboot completion MW 9 Wait for the terminal to write the new image to flash memory During this operation the terminal displays UPDATE A5 on the splash screen After about one minute the terminal displays Update Complete 132 Publication 2711C UMO01F EN P November 2010 Firmware Update Utility Appendix E The terminal reboots itself when the new image is successfully written to flash memory Please keep terminal powered on until it fully boots up A 10 Observe the firmware version information of the new image The firmware version is displayed on the startup screen and will also appear on the System Information screen when the terminal is in configuration mode Clean File System or The procedure shows how to clean the file system and the registry You can perform clean file system and clean registry operation separately or at the same Clean Registry T IMPORTANT Cleaning the Tile system remov
124. tomatic Private IP Address or auto IP address The auto IP address will be in the range of 169 254 0 0 through 169 254 255 255 The terminal makes sure the auto IP address is unique from any other auto IP address of other devices on the network The terminal can now communicate with other devices on the network that have IP addresses in the 169 254 xxx xxx range and a subnet mask of 255 255 0 0 For the USB port use the default IP address that is set when the terminal is connected to the computer This address is 169 254 254 2 It is not recommended to change this setting IMPORTANT Ethernet Settings Parameter Description MAC ID Read only field that defines the MAC ID of the PanelView Component terminal Each Ethernet device has a unique MAC ID Network Device Name Unique name that identifies the terminal on the network IP Address Unique address that identifies the terminal on the Ethernet network The format of the IP address is XXX XXX XXX XXX for example 10 90 95 30 The range of values for the first set of decimal numbers is 1 255 unless all fields are set to 000 The range of values for the last three sets of decimal numbers if 0 255 Subnet Mask Address that must be identical to the server subnet mask The subnet mask is formatted like the IP address Default Gateway Optional address that is formatted like the IP address Publication 2711C UM001F EN P November 2010 Configuration Mode Chapter 2
125. ty and forgot your password you can use this procedure to restore your terminal Remember it will remove all applications logs recipes user installed font files objects and graphics 93 Chapter 6 Notes 94 Troubleshoot the System Publication 2711C UM001F EN P November 2010 General Specifications Publication 2711C UMO001F EN P November 2010 Specifications Appendix A PanelView Component 2711C F2M 2711C K2M 2711C T3M 2711C K3M Attribute Display type C200 C300 C600 C1000 Display size C200 C300 C600 C1000 Display area C200 C300 C600 C1000 Resolution pixels C200 C300 C600 C1000 Backlight C200 C300 C600 and C1000 C600 2711C T6T Operator input C200 C300 C600 and C1000 Memory card C200 and C300 C600 and C1000 Programming port Battery life 2711C T6M 2711C T6C 2711C T6T 2711C T10C Value Monochrome transflective STN passive matrix Monochrome transflective FSTN passive matrix Monochrome transmissive FSTN passive matrix or Color transmissive CSTN passive matrix or Color transmissive TFT active matrix LCD Color transmissive TFT active matrix LCD 2 In 3 In 5 7 In 10 4 in 49 x 14 mm 1 93 x 0 55 in 67 x 33 mm 2 64 x 1 30 in 115 x 86 mm 4 53 x 3 39 in 211 x 158 mm 8 31 x 6 22 in 122 x 32 128 x 64 320 x 240 640 x 480 50 000 hours life min backlight not replaceable Yellow Green status indicator White stat
126. ual since the last publication To help you find new and updated information in this release of the manual we included change bars as shown to the right of this paragraph Topic Section Updated supported browsers and platforms page 18 Added section for adding PanelView page 99 Component DesignStation 2 0 fonts Added a chapter for PanelView Component page 119 DesignStation 2 0 Publication 2711C UMO001F EN P November 2010 3 summary of Changes Notes 4 Publication 2711C UM001F EN P November 2010 Summary of Changes Table of Contents Preface Overview Configuration Mode Install and Replace Components Cable Connections and Communication Publication 2711C UMO001F EN P November 2010 Table of Contents ODieCh esse bodas atia eee edt todo dap dort ott desde tuus 9 Intended ele HC E oua bone arrest andere eea 9 Addinonal RESOULCES s a 2a draia a o E ar PA rc CR ae es 9 Dnbvare Upotad Serea yee E E E A E AES 10 Chapter 1 Chapter ODicChVeS 4442 ninaa aa aa Eme d due aede 11 ADOG Ne Terni Ss 5r om e o wo ure 5 a A E ee 11 Howto Connect Browser cao REA USER AIR RE EES 12 Panel View EP Xplorer voveo v beach ates tebe eeu oh eee DI P ESSA 14 FON OSs Iai Cle cue tene eru aru Oda ioa p Eek erit pee 15 Peripheral COnnechOn ta dele rd EP E ei a i 16 Catalog Number Configuration aici sid dome bou arr e tinet eure 16 Chapter 2 Succ Sui CPP P oes Cee Rea a hate neo 17 Gonfe ratom MOGG caue dade d actor 0e bed
127. us indicator CCFL 40 000 hours life min backlight not replaceable White LED Function keys or combination function keys and numeric keypad Analog touch or combination function keys and numeric keypad Analog touch USB port USB port and Secure digital SD card USB device port 5 years min at 25 C 77 F 95 Appendix A Specifications Environmental 96 PanelView Component 2711C F2M 2711C K2M 2711C T3M 2711C K3M 2711C T6M 2711C T6C 2711C T6T 2711C T10C Attribute Real time clock C200 and C300 C600 and C1000 Input voltage range Power consumption max C200 and C300 C600 C1000 Weight approx C200 function key C200 keypad C300 keypad C300 touch C600 touch C1000 touch Dimensions HxWxD approx C200 function key C300 touch C200 keypad C300 keypad C600 touch C1000 touch Attribute Temperature operating Temperature nonoperating Heat dissipation C200 and C300 C600 C1000 Relative humidity shock operating shock nonoperating Vibration Enclosure type ratings Value No battery backup Battery backup 18 30V DC 24V DC nom 5 W 0 21 A at 24V DC 10 W 0 42 A at 24V DC 18 W 0 75 A at 24V DC 0 19 kg 0 40 Ib 0 30 kg 0 65 Ib 0 20 kg 0 43 Ib 0 68 kg 1 48 Ib 1 57 kg 3 41 Ib 80 x 116 x 54 mm 3 15 x 4 54 x 2 13 in 80 x 116 x 57 mm 3 15 x 4 54 x 2 23 in 119 x 139 x 55 mm 4 69 x 5 47 x 2 15 in 154 x 209 x 57 mm 6 0 x 8 23 x 2 25 in 2
128. utton To clear cache in the Internet Explorer browser select Tools gt Internet Options On the General tab click the Delete button under Temporary Internet Files to delete all temporary internet files including offline content 71 Chapter 5 Upgrade Firmware 78 Changing the firmware will likely change the behavior of the terminal Be aware of the firmware versions for the terminal versus the new firmware that is on the computer and be informed of the expected behavior after the new firmware is installed on the terminal Prepare the Storage Device Follow these steps to prepare the storage device to transfer firmware files 1 Insert the storage device into a USB host port or an SD card slot that is on your computer Open a web browser and access the PanelView Component technical support website Locate the new firmware file Observe the firmware version information that is in the name of the firmware file and confirm that this is the new desired firmware Download the firmware file to a folder on your computer then open the file and unpack the contents of the firmware file to an SD card or USB flash drive root directory Install the Firmware from the Storage Device Follow these steps to transfer firmware files from a storage device 1 Open the system information screen to see the firmware version information for the terminal Q Allen Bradley System Information Firmware Version
129. w Explorer e How to display help e Peripheral connection e Catalog number configuration PanelView Component terminals are operator interface devices for monitoring and controlling devices attached to a controller HMI applications are created using a Web application while your computer is connected directly to the terminal You see the direct result on the terminal display without having to download first PanelView Component C200 and C300 Terminals f PanelView C300 PanelView C200 Y 1 Function keys keypad or touch 4 USB device port display 2 24V DC power input Ea RS 232 serial port 3 RS 422 and RS 485 port USB host port 11 Chapter 1 Overview How to Connect Browser 12 PanelView Component C600 and C1000 Terminals 10 C600 Series C terminal shown H 1 Touch display 9 RS 232 serial port 2 24V DC power input 7 USB device port 3 10 100 MBit Ethernet port ia Diagnostic status indicator 4 RS 422 or RS 485 port Replaceable real time clock battery 5 Mounting slots for 2711C T6M ao USB host port 6C Series C or later 2711C T6T Series A or later E Secure digital SD c