Pyramix v9 Installation Guide
Contents
1. Pyramix DIGITAL AUDIO WORKSTATION 15 Index 34 Installation Guide V9 x Contents AMERGING Installation Guide Document Pyramix v9 x Installation Guide rev8 Date 14th May 2014 a Pyramix DIGITAL AUDIO WORKSTATION 1 Introduction Thank you Scope y Congratulations on your purchase of Pyramix Virtual Studio More than just a product this is a gateway to the future of sound recording editing mixing and mastering You have joined a worldwide community of users who have already discovered the Pyramix advantage Note IMPORTANT The first thing you need to do is register your software to acquire your Pyramix key s and to be included in our user support list http www merging com register Please also subscribe to the User Forum at http forum merging com Pyramix Virtual Studio is a powerful and flexible Digital Audio Workstation DAW integrating hard disk recording and editing digital audio mixing effects processing metering machine control video and mastering Complete turnkey systems are available This document is intended to get you up and running with Pyramix Pyramix MassCore and Pyramix MassCore RAVENNA as quickly as possible For more detailed information about the Horus Mykerinos and Mykerinos X hard ware and the Pyramix software please see their specific Guides Important If you are installing an upgrade to Pyramix please read For Users Per forming Upgrades on
2. 5 Select Internet Protocol Version 4 TPC IPv4 which is the only one activated and click on Properties 6 Switch to Use the following IP address and enter an IP address that is in the same range as the Horus IP address The Subnet Mask should be added automatically 7 Clickon OK in each dialog to accept the changes and close the dialogs Windows Firewall and UAC Recommendation If not configured correctly Windows Firewall can block communication between MassCore and Horus User Account Control should also be set to Never Notify Firewall Open the Windows Control Panel Open the System and Security section and under Windows Firewall disable the Firewall for the Public Network Go back to the Windows Control Panel and click on Windows Firewall Click on Change notification settings Ensure Block all incoming connections including those in the list of allowed programs is NOT ticked User Account Control Open the Windows Control Panel Open the User Accounts section and under Change User Account Control Settings move the slider down to Never Notify Antivirus Recommendation Merging also recommends that any Antivirus software be disabled Some Antivirus software such as Avast have been known to block the Horus discovery and RAVENNA I O connections Installation Guide MassCore RAVENNA a Pyramix DIGITAL AUDIO WORKSTATION 11 First launch Important After installation has been completed please reboot the PC bef
3. Please take all of the necessary precautions when handling the Mykerinos board and all other PC computer cards Mykerinos Card Installation Note Note for multiboard installation care must be taken in the selection of the PC chassis components to ensure adequate thermal dissipation through sufficient fan air cooling Inserting the Mykerinos Audio Board s Make sure the computer is turned off and unplugged before installing the Mykerinos board To avoid the possibility of static electricity damage to the PC or the Mykerinos board s please use an anti static strap to connect yourself to a known good earth Remove the computer covers required to gain access to the peripheral slots Locate a free PCI Mykerinos or PCl e Mykerinos X slot It is generally inadvisable to use the slot adjacent to an AGP slot Remove a slot bracket for the chosen slot s if needed Insert the Mykerinos board s into the chosen slot s Ensure each Mykerinos is properly seated in the slot Fit any extra break out connector brackets if applicable Fasten the mounting screw to secure the Mykerinos back plate to the PC frame Multi board Installation For multiboard installation it is advisable to insert all Mykerinos boards in adjacent slots sharing the same PCI bus segment Please refer to PC motherboard documentation In order to enable multi board operation all Mykerinos cards in the PC must to be connected together using a special HDTDM ribbon cab
4. VCube and Ovation Choosing Ovation will also install Pyramix You may exclude the installation of any of the individual components in the wizard if the device in question is not present on your machine or if you do not intend to use an item by un ticking the tick boxes next to the items listed in the wizard Note The security dongle or Mykerinos card must be in place and the security keys entered before attempting to launch the software Driver Signing There is no Driver Signing Options dialog in Windows 7 Windows throws up a warning dialog when unsigned drivers are installed To avoid the necessity of clicking on OK several times you may wish to check the Always Trust Drivers from Merging Technologies box Flux VS3 V3 plug ins The Flux plug ins are not bundled in the installer they must be installed separately Two versions are available 32 bit and 64 bit Download the appropriate installer and ensure you have valid Merging Flux v3 Keys in order to run these Flux VS3 plug ins https www fluxhome com download Installation Guide Pyramix Software Installation AMERGING a Pyramix DIGITAL AUDIO WORKSTATION Running the Installer y wn Note If you have a SafeNet dongle please remove this before installing Pyramix and replace it after installation is complete Note The HASP dongle is not supported on 64 bit systems If you have a HASP dongle please contact your Merging Technologies Sales Partner to purchase
5. click the Enter Key button and type your User Name Company Name and Key then click OK Repeat this step for each Keys listed in the email Changing or re entering a Key Should you need to subsequently change or re enter a Key follow the appropriate option above The key system is smart Only one key or set of keys is required regardless of the number of boards in a system Any card can hold this key set as the authorization is processed based on a Logical OR of all keys present on any and all Mykerinos boards Of course this Logical OR will only process keys with identical User Name and Company Name to the one entered in the key enabling window Installation Guide Pyramix Software Registration AMERGING Pyramix DIGITAL AUDIO WORKSTATION Evaluation Mode If started without a valid registration key the software will recognize that no valid key is available and will start in evaluation mode which only allows for basic operation of the software as follows Limited to 2 channels of I O on host soundcard No Project gt Save function Tone is added to new recordings All optional extra cost features are deactivated All editing functions playback file type conversions etc are fully functional Keys At any time you can check the serial number of your Security dongle or Mykerinos card s and check the software options enabled in your system in the MTSecurity application amp Merging Technologies
6. Guide System Requirements Pyramix DIGITAL AUDIO WORKSTATION Pyramix Native Certified Operating Systems OS We recommend and certify Pyramix Version 9 x under Windows 7 Professional 32 bit and 64 bit MassCore and Networks Increase Scheduling Priority For satisfactory operation over a network you must add the User Group to which the User belongs to Increase Scheduling priority policy with the help of gpedit msc If the Machine belongs to a domain the Administrator of the domain must do this if not then the Administrator of the system Procedure 1 Open the Local Group Policy Editor Start gt Accessories gt Run and type or paste gpedit msc File Action View Help Local Computer Policy 4 amp Computer Configuration _ Software Settings Windows Settings Scnpts Startup Shutdown a Deployed Printers 4 A Security Settings _ Account Policies 4 Local Policies Audit Policy User Rights Assignment T Security Options 3 Windows Firewall with Advanced Se _ Public Key Policies 1 Software Restriction Policies amp IP Security Policies on Local Compu gh Policy based QoS 1 Administrative Templates yl User Configuration C Software Settings Windows Settings Administrative Templates Policy Change the time zone Create a pagefile Create token object Create global objects Create permanent shared objects Create symbolic links Debug programs Deny access to this comp
7. Merging Technologies NET MSC GBEX1 PCle Ethernet Controller Card The NET MSC GBEX1 PCle card should be installed in your computer before installing Pyramix v9 x The NET MSC GB EX1 card Procedure 1 Power down your PC and switch it off at the wall Remove the screws securing the top or side of the case and carefully slide off the panel 2 Ananti static wristband is sensible precaution whenever working with sensitive electrical equipment Keep ing one hand on a metal part of the case will have the same effect though you may need both hands when installing certain items of hardware 3 Locate an empty PCle slot and remove the metal backing plate by removing the screw holding it in place and carefully sliding it up and out In some cases there no backing plates and you will need to remove a length of metal instead Do this using a flat blade screwdriver and or pliers taking care to avoid any sharp edges left behind Installation Guide MassCore RAVENNA AMERGING a Pyramix DIGITAL AUDIO WORKSTATION 4 Remove the NET MSC GBEX1 card from its protective anti static envelope and align it with the vacant PCle slot as shown below PEEL m ELEM MENS Lo mmn kab y mes ww 80008395 N S 4X3800 2 W13N Installing the NET MSC GB EX1 card 5 Push down gently at first ensuring you have the pins aligned correctly with the slot and then apply more pressure to slot the card fully home 6 Use the scr
8. NET MSC GBEX1 Ethernet card in your system You must have a MassCore 48 Base Key in order to proceed with the installation For 64 bit systems you must also have a MassCore 64bit Base key and an RTX 64 key Please contact your Merging Technologies Sales Partner if you do not have these options but want to use MassCore MassCore Installation 1 Install v9 x Pyramix exe 2 Restart your system after the Pyramix install 3 Enter Your Key s in MT Security Panel Make sure you have a valid MassCore key The MassCore 64bit and RTX64 keys are required for 64 bit systems 4 Forautomatic RTX licence validation on 64 bit systems ensure the system is connected to the Internet during the MassCore installation In the MT Security Panel select the MassCore Tab 6 Pressthe Install MassCore RunTime button will only be enabled if the MassCore Base Key is present 4 Merging Technologies Security Settings Keys MTActiveKey MassCore About y MassCore Unlimited e MassCore Run Time not installed on this computer Please install it Install MassCore Run Time VS3 merging Technologies Security Settings dialog 7 Restart System after the install Installation Guide MassCore Installation AMERGING a Pyramix DIGITAL AUDIO WORKSTATION 8 Launch the VS3 Control Panel 9 Inthe Platform section select MassCore 10 We recommend the use of Low latency mode by default Ultra low latency amp Extra low latency are
9. a SafeNet dongle and transfer your keys Once the NET MSC GBEX1 Ethernet card and or Mykerinos card s have been properly installed you can now install the Pyramix 9 x software To install the Pyramix Virtual Studio v9 x software insert the USB memory stick The installation program will auto start on a PC where auto start is configured on Otherwise double click on the USB memory stick icon Please follow the automatic installation procedure accepting the option to install unsigned drivers one per Mykerinos board and re boot your PC once setup is complete Note If the installation appears to freeze for a long period please check that the Driver Signing warning dialogue is not hidden behind another Window Installation will not continue until you click OK in this dialog WARNING Certain computers do not properly shut down despite the reboot command issued by the installer but only perform a log off In this case please activate a full shut down manually Installation Guide Pyramix Software Installation a Pyramix DIGITAL AUDIO WORKSTATION 8 Pyramix Software Registration The Pyramix Virtual Studio software and its various software options are protected by an authorization key mechanism which uses a unique registration key number generated by Merging Technologies Based on pur chased software components this key is unique to your security dongle or Mykerinos board serial number your Company Name and your User name Once
10. install the new version of MassCore N n P gt b N Reboot the machine Note A second automatic reboot will occur after the first login Note After the installation you should see two Interval Zero entries in Windows Con trol Panel gt Programs and Features which are For 32 bit systems 1 Interval Zero RTX 2011 with Service Pack 1 Runtime Professional 2 Interval Zero RTX 2011 with Service Pack 1 Update 5 Installed For 64 bit systems 1 Interval Zero RTX64 2013 Runtime with Service Pack 1 If these entries are not present please refer to the troubleshooting advice document here http www merging com uploads assets Installers Pyramix 8 1 IntervalZeroRTX Uninstall Troubleshoot pdf Installation Guide For Users Performing Upgrades AMERGING a Pyramix DIGITAL AUDIO WORKSTATION 4 System Requirements Wintel platforms tend to increase in number of cores speed and performance at a tremendous rate New and faster processors are released almost on a monthly basis Therefore we have not included suggested Motherboard or Processor specifications here We maintain a list of up to date PC configurations in the Support Section of our website at http www merging com pages pcconfig Other Components Graphics Card In many situations the Intel Integrated Graphics where supported by the motherboard and CPU are perfectly adequate If a graphics card is desired or required Merging recommend the ATI FIREPRO seri
11. same computer we recommend a quad core Processor PC with one or two CPUs a dedicated hard drive for the video and Windows 7 Professional Installation Guide PC Setup AMERGING a Pyramix DIGITAL AUDIO WORKSTATION Recommended options Internet Connection this will allow you to upgrade the software easily by connecting to our Web site and to communicate queries or suggestions to Merging by Email PCI MIDI Interface card where none is fitted to the motherboard or Sound Card with Midi interface or USB MIDI driver where appropriate for customers wishing to use Pyramix MIDI functions for example to interface Pyramix with an external Midi remote controller such as J L Cooper MCS series Raditek SAC 2k Mackie Control or external digital mixer such as y wn Sony DMX R100 Yamaha DM 2000 Yamaha DM 1000 Yamaha 02R 96 Installation Guide PC Setup a Pyramix DIGITAL AUDIO WORKSTATION 6 Mykerinos Installation IMPORTANT NOTICE Mykerinos cards are supported ONLY on 32 bit systems Please read the following information very carefully before attempting any installation Failure to comply with the precise instructions may result in damage to your Merging hardware Please read the entire chapter carefully before installation STATIC DANGER NOTICE Please note that the Mykerinos Audio Board contains delicate electronic components that can be damaged or even destroyed when exposed to static electricity
12. you have registered your software you will be provided with this Key or Keys depending on the chosen options Ina multi board system only one key is required for all connected boards The master board validates the others If you did not receive this key have lost it or would like to change the user and or company name please contact your Merging Sales Partner with your Mykerinos serial your User Name your Company Name and the list of pur chased software components Usually a key can be issued within one business day after the verification of your personal data has been completed Entering your Key s After the Pyramix installation process you will be prompted to enter your Authorization Key If you click Yes the MT Security Settings dialog will be launched automatically allowing the Key or Keys to be entered immediately If you choose not to enter your Key at this point you can do so later by choosing one of the following procedures 1 Double click the file YourPersonalKeyXXXXX mtk This is attached to the email containing your Key s 2 Open the MT Security Settings Control Panel Windows Task Bar Start gt Control Panel gt MT Security Settings click the Import Key button and browse for your Key file called YourPersonalKeyXXXXX mtk 3 Open the MT Security Settings Control Panel as above in the Registration section select the board num ber corresponding to the serial number for your Keys or HASP SafeNet Key for a dongle
13. 1 MassCore Dedicated Latency 9 Low latency 5 33ms 48 96 192 384KHz Extra low latency 2 66ms 48 96 192 384KHz i Ultra low latency 1 33ms 48 96 192 384KHz Hardware On Bus Video TC Monitor Jack zm m o Ravenna Audio Bridge Disable ASIO Number of Channels 1 0 16 Rewire oo a VS3 Merging Technologies Virtual Studios Control Panel 1 Launch the VS3 Control Panel Start All Programs gt Merging Technologies gt VS3 Runtime gt VS3 Control Panel 2 Cores Allocation Leave on the default setting for now ad For now leave Latency on the default setting Low Latency only mode supported at present on 32bit sys tems Select Platform MassCore Select Hardware On Bus as RAVENNA box ticked Audio Bridge Set as required Click on the OK button When the VS3 panel Do you want to save routing dialog box appears click on OK o0 o N o m the VS3 control panel will close Before First Launch Before launching Pyramix v9 you must ensure that a PTP Master is present on your RAVENNA network Merging Technologies recommends using its Horus converter as PTP Master The Precision Time Protocol PTP is a protocol used to synchronize clocks throughout a computer network Note As of v9 x RAVENNA mode supports all three Latency modes VS3 Control Panel To enable RAVENNA I O connections please refer to the separate RAVENNA Easy Connect Guide Note Horus us
14. E CHEETA Enterthe object names to select examples Installation Guide System Requirements a Pyramix DIGITAL AUDIO WORKSTATION Select the types of objects you want to find Object types v Built in security principals V Users Object Types dialog 6 Ensure that Groups is ticked and click on OK to close the dialog 7 Inthe Select Users or Groups dialog type the name of the User Group the user or users belong to e g Users in the Enter the object names to select field and click on the OK button to close the dialog 8 The Group name you typed in step 5 should now appear in the increase scheduling priority Properties dialog list 9 Clickon the OK button to close the dialog Note that the Groups selection in the Object Types dialog is temporary and must be selected every time you wish to add or remove a Group Installation Guide System Requirements AMERGING a Pyramix DIGITAL AUDIO WORKSTATION 5 PC Setup Motherboard Drivers and Utilities Motherboard drivers should be updated to current versions Motherboard Utilities should NOT be installed BIOS Settings Recommended BIOS Settings The following features can create MassCore overloads blinking red MSC Intel Hyperthreading Technology is supported on 64 bit MassCore systems but NOT on 32 bit systems this set ting must be disabled for the relevant CPU s This setting is commonly found in Main Bios page or under CP
15. Menu All Programs Merging Tech nologies Merging RAVENNA ASIO Driver Merging RAVENNA ASIO Panel please see details in the Merging RAVENNA ASIO and CoreAudio Guide available in Start Menu gt All Programs gt Merging Technologies gt Documen tation Merging RAVENNA ASIO Driver Merging RAVENNA ASIO Panel Select ASIO RAVENNA in the VS3 Control Panel Start Menu Control Panel VS3 Control Panel Mykerinos only Not supported on version 9 upgrade to MassCore mandatory Installation Guide Pyramix Versions Compatibility and Installation Steps AMERGING a Pyramix DIGITAL AUDIO WORKSTATION MassCore with Mykerinos Compatibility Windows 7 Professional 32 bit ONLY Installation Steps Mykerinos Installation See Mykerinos Installation on page 16 Pyramix Software Installation See Pyramix Software Installation on page 17 Entering Authorization Keys See Pyramix Software Registration on page 19 MassCore Installation See MassCore Installation on page 21 Select MassCore with Mykerinos in the VS3 Control Panel Start Menu gt Control Panel gt VS3 Control Panel MassCore with RAVENNA and Horus Compatibility Windows 7 Professional 32 bit or 64 bit Installation Steps NET MSC GBEX1 Installation See Installing the Merging Technologies NET MSC GBEX1 PCIe Ethernet Controller Card on page 23 Pyramix Software Installation See Pyramix Software Installation on page 17 Entering Authorization Key
16. Net amp IntervalZero HASP THis solution requires the purchase of an additional dongle Please contact your local Merging Technologies sales office if you require this option Installation Guide MassCore Installation AMERGING Pyramix DIGITAL AUDIO WORKSTATION Re licencing MassCore 64 bit RTX If a systems needs to be re licenced for example after a Windows OS re installation process or if it is necessary to move the licence to another system then you will have to contact Interval Zero in order to complete the re licenc ing process as Merging is not able to provide this service Ensure that you have the RTX64 Authorization Key num ber RTX64 XXX2000CXXXX when doing so Interval Zero Support team http www intervalzero com technical support Installation Guide MassCore Installation AMERGING a Pyramix DIGITAL AUDIO WORKSTATION 10 MassCore RAVENNA Certified Operating Systems OS for RAVENNA Pyramix Version 9 x MassCore in RAVENNA mode is certified under Windows 7 Professional 32 bit and 64 bit ver sions ONLY System Requirements We maintain a list of up to date PC configurations in the Support Section of our website at http www merging com pages pcconfig Please refer to the MassCore RAVENNA recommendations Quad Core is the minimum requirement Required Hardware The Merging Technologies NET MSC GBEX1 PCle Ethernet controller card is required for MassCore RAVENNA Installing the
17. Pyramix DIGITAL AUDIO WORKSTATION Installation Guide v Pyramix DIGITAL AUDIO WORKSTATION y No part of this documentation may be reproduced in any form whatsoever or be stored in any data retrieval system without prior written permission of the copyright owners This documentation is supplied on an as is basis Information contained within this documenta tion is subject to change at any time without notice and must not be relied upon All company and product names are or Registered Trademarks of their respective owners Windows 7 Windows Vista and Windows XP are trademarks of Microsoft Corporation Merging Technologies makes no warranties express or implied regarding this software its qual ity performance merchantability or fitness for a particular purpose The software is supplied as is you the purchaser are assuming the entire risk of the results of using this Merging Technolo gies software In no circumstances will Merging Technologies its owners directors officers employees or agents be liable to you for any consequential incidental or indirect loss or damages including loss of time loss of business loss of profits loss of data or similar resulting from the use of or inability to use the Merging Technologies hardware and or software or for any defect in the hardware software or documentation Copyright Merging Technologies Inc 2014 All rights reserved Merging Technologies Le
18. Security Settings Keys MTActiveKey MassCore About Regestration 74 SsfeNet Key V Include Keys tored on SafeNet Donges n MT Securty Sensl Number 50000XXXX User Name Ricardo Ryan Company Name Merging Technologies Keys Ogtoes Vabdty Pyramix Core 29 Sep 2014 Erter Key High Sampling Frequency 23 Sep 2014 Surround Mong 29 Seo 2014 t TemeCode Support 29 Sep 2014 Remove Al Keys Machine Control Support 29 Sep 2014 f WterChange Final Cut Pro XML 23 Sep 2014 Remete Control Support 29 Sep 2014 Pyromix Native Audo Enabled 29 Sep 2014 Update User Extended Native Audio Suppot 23 Sep 2014 Native Audo Support 23 Sep 2014 Limted Native Audio Suppod CO R Support 29 Sep 2014 DDP Suppot 23 Sep 2014 SACD DSD Suppe 23 Sep 2014 Cue Sequencer Cue Sheet Prrter 29 Sep 2014 kterChange Akai DO Senes 23 Sep 2014 kterchange OMF 23 Sep 2014 kteChange Open TL 29 Sep 2014 E m MT Security Settings Keys tab Installation Guide Pyramix Software Registration AMERGING a Pyramix DIGITAL AUDIO WORKSTATION 9 MassCore Installation System Requirements A quad core Intel processor is the minimum requirement Conditions You MUST be logged in as an Administrator to install MassCore Note You do not need to be logged in as an Administrator to RUN Pyramix with Mass Core just to install it You must have at least one Mykerinos board or a
19. U configuration see the motherboard manual for further details Intel Speedstep Technology also known as Enhanced Intel SpeedStep as well as CPU C State or Intel C State features must be disabled in the BIOS Some Recent Intel boards have a global setting to disable those features known as Intel Dynamic Power Technol ogy If present this should be turned off These settings are commonly found in BIOS Power options or CPU Config uration Overclocking is not supported Display Settings Pyramix requires a minimum display resolution of 1280x1024 in 256 colors which MUST be set to small fonts mode We strongly recommend turning OFF the Aero feature for maximum performance Power Management N B As with other Digital Audio Workstations and Non Linear Editors we recommend setting the PC to an Always On Power management scheme This allows the monitor to be turned off by the system but disables hard disk spin down and Standby MassCore is not designed to support Standby modes Aero graphics Disable AERO themes for maximum performance Indexing In the interests of better performance we recommend turning Indexing OFF for all Data drives in the system Other Applications Like all Digital Audio Workstations Pyramix works best when there are no other unnecessary applications or ser vices running Video and Pyramix on one PC To ensure a very smooth system especially for seeking when playing video with Pyramix on the
20. Verney 4 1070 Puidoux Switzerland Tel 41 21 946 04 44 e Fax 41 21 946 04 45 www merging com O Pyramix DIGITAL AUDIO WORKSTATION Installation Guide V9 x IMPORTANT NOTICE Please read the following information very carefully before attempting any installation Failure to comply with the precise instructions may result in damage to your Merging hardware Please read this entire section of the manual carefully before installation STATIC DANGER NOTICE Please note that the Mykerinos and Mykerinos X boards contain delicate electronic components that can be dam aged or even destroyed when exposed to static electricity Take all necessary precautions not to discharge static electricity when touching any of the Mykerinos components INFORMATION FOR THE USER 7 Mykerinos Mykerinos X and their daughter cards comply with the following specifications EMC Emissions EN 55022 1994 A1 1995 A2 1997 Class A ITE emissions requirements EU FCC 47 CFR Part 15 Class A emissions requirements USA EMC Immunity EN 50082 1 1992 EMC residential commercial and light industrial generic immunity standard FCC Notice This product has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interfer ence and 2 This device must accept any interference received includin
21. available for Horus users with Pyramix v9 x recommended configurations http www merging com pages pcconfig Merging Technologies Virtual Studio Settin n Application Pyramix Virtual Studio Platform MassCore Latency Ultra low latency 1 33ms 48 96 192 384KHz C Extra low latency 2 66ms 48 96 192 384KHz Low latency 5 33ms 48 96 192 384KHz Hardware On Bus Video TC AES EBU 211291 168MHz ADAT 811290 168MHz OK Cancel VS3 Merging Technologies Virtual Studios Settings dialog 64 Bit MassCore Notes Double licence protection both MassCore 64bit and RTX64 keys are required BEFORE MassCore installa tion The MassCore 64 bit installation can be performed only if these two keys are present The RTX64 Activation key licence is authorized by an online tool on Interval Zero s site after the Merging software MassCore installation is complete Note that the RTX64 MassCore licence can only be installed ONCE since it is locked to the system At present if there is a requirement use MassCore Pyramix on two different computers regularly it will be necessary to purchase a second MassCore 64bit Base key Note that a solution exists for those who would like to have their MassCore RTX64bit keys stored on a dongle Hasp IntervalZero instead of having them linked to a unique system This allows users to move their MassCore RTX64 licensing to different systems by carrying two dongles Merging Safe
22. ers should refer to the Horus User Manual for configuration set up with Pyramix Installation Guide MassCore RAVENNA AMERGING a Pyramix DIGITAL AUDIO WORKSTATION Troubleshooting y RAVENNA Horus amp Network configuration Merging recommend that the Ethernet MassCore card and Horus are configured to obtain an IP address automat ically Setting Horus and Network Card to Obtain IP Addresses Automatically Network Card 1 Open Network Connections in the Windows Control Panel 2 Right click on the MassCore Ethernet card NET MSC GBEX1 and open Properties 3 Select Internet Protocol Version 4 TPC IPv4 which is the only one activated and click on Properties 4 Selectthe Obtain an IP address automatically option 5 Clickon OK in each dialog to accept the changes and close the dialogs Horus 1 Open the Horus Setup Advanced gt Network page 2 Inthe IP address section select Auto Setting Fixed IP addresses 1 First check the IP address of the Horus device under Setup Network To be able to see each other the Merging Technologies Network card and Horus must be in the same range of addresses for example 192 168 xxx xx 2 The Horus IP address can be checked and changed if required in the Horus Setup page Network 3 ThelP address of the MT Network card can be changed in Windows Control Panel Change Adapter Set tings 4 Right click on the Merging Technologies NIC and select Properties
23. es of PCle graphics cards Sufficient HD space and speed for your audio media files The speed and amount of disk space required depends on sample rate wordlength number of tracks and length of program material A typical 7200 RPM SATA drive is sufficient for 48 tracks at 48 kHz Higher track counts and or higher sam pling rates will require an SSD drive and or multiple drives configured in Raid 0 1 10 or 5 We recommend disks should be formatted as NTFS volumes with 64kB block sectors BD DVD CD ROM combo drive or better Multiple 19 or larger monitors highly recommended Minimum resolution 1280x1024 3 button mouse Mykerinos Systems Certified Operating Systems OS We recommend and certify Pyramix Version 9 0 and later under Windows 7 Professional 32 bit version Note Although not certified Pyramix has also been observed to work under the Home edi tions of Windows 7 32 bit without any known edition related issues to date Note NEVER attempt to install Pyramix on Windows NT Server Pyramix MassCore Systems y wn Certified Operating Systems OS We recommend and certify Pyramix Version 9 0 and later under Windows 7 Professional Note MassCore RAVENNA is ONLY certified under Windows 7 Professional 32 bit or 64 bit versions Note Although not certified Pyramix with MassCore has also been observed to work under the Home editions of Windows 7 without any known edition related issues to date Installation
24. ew which was used to retain the backing plate to secure the card in place and check that the card sits comfortably 7 Finally replace the case cover s and switch the machine back on at the socket 8 At the next power up and boot Windows will discover the Merging Ethernet PCle card Pyramix v9 can now be installed Reguired Software In order to operate Pyramix with RAVENNA and Horus Pyramix v9 or later must be installed The Pyramix installer includes the MT Discovery tool along with Apple bonjour Note Driver signing Please tick Always trust Merging Technologies when the first warning message about unsigned drivers appears Enter your Pyramix keys Launch MTSecurity settings and enter your Pyramix v9 keys Please see Entering your Key s on page 21 Install MassCore Please see MassCore Installation on page 23 Note A valid MassCore Base key is mandatory The MassCore key is held on the Safenet dongle Please make sure that you are in posses sion of a dongle and valid keys in order to operate Pyramix in MassCore RAVENNA mode Note The NET MSC GBEX1 Ethernet card requires MassCore in order to function Installation Guide MassCore RAVENNA AMERGING a Pyramix DIGITAL AUDIO WORKSTATION Configure RAVENNA in the VS3 Control Panel r Merging Technol 1 Application Pyramix Virtual Studio gt Platform MassCore J Cores Allocation shared bv all applications Windows 3 0
25. g interference that may cause undesired operation These limits are designed for providing reasonable protection against harmful interference in a residential installa tion This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions contained in this manual may cause harmful interference to radio and television communications However there is no guarantee that interference will not occur in a particular installation Note Connecting this device to peripheral devices that do not comply with CLASS A requirements or using an unshielded peripheral data cable could also result in harmful interference to radio or television reception The user is cautioned that any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment To ensure that the use of this prod uct does not contribute to interference it is necessary to use shielded I O cables CE Notice Such a C marking is indicative that this system s devices meet the following applicable technical standards EN 55022 Information Technology Equipment Radio disturbance characteristics Limits and methods of measurement EN 50082 1 1992 Electromagnetic compatibility Generic immunity standard Part 1 Residential com mercial and light industry Installation Guide V9 x Pyramix DIGITAL AUDIO WORKSTATION T
26. his product is classified for use in a typical Class A commercial environment and is not designed or intended for use in other EMC environments The user of this product is obliged for proper use and installation of the product and for taking all steps necessary to remove sources of interference to telecommunications or other devices Hardware Warranty Information y wn This product is warranted to be free of defects in materials and workmanship for a period of one year from the date of purchase Merging Technologies Inc extends this Limited Warranty to the original purchaser In the event of a defect or failure to confirm to this Limited warranty Merging Technologies Inc will repair or replace the product without charge within sixty 60 days In order to make a claim under this limited warranty the purchaser must notify Merging Technologies Inc or their representative in writing of the product failure In this limited warranty the customer must upon Merging Technologies Inc request return the product to the place of purchase or other local designation for the necessary repairs to be performed If the consumer is not satisfied with the repair Merging Technologies Inc will have the option to either attempt a further repair or refund the purchase price This warranty does not cover 1 Products which have been subject to misuse abuse accident physical damage neglect exposure to fire water or excessive changes in the climate or
27. le with 30 pin plugs This cable has to be plugged into the multi pin connectors located on the top edge of the I O daughter cards Please contact your Merging Technologies Sales Partner for information on how to order the HDTDM ribbon cable Note to reduce the risk of electro magnetic interference being induced by other PCI cards into the highly sensitive Mic Preamp circuitry systems equipped with Merging s DUAL Analog AES daughtercard are best installed in a slot with no other card inserted in the immediately adjacent slot I e the component side of the card which will be on the left looking from the front of a conventional PC chassis Installation Guide Mykerinos Installation AMERGING a Pyramix DIGITAL AUDIO WORKSTATION 7 Pyramix Software Installation Note You must have full Administrator Access to install Pyramix Installation Overview Note If you have purchased hardware options such as Mykerinos cards the NET MSC GBEX1 PCle Ethernet card the Sync Board and or an AJA video card please install these following the instructions in the accompanying documentation The drivers for all of these are installed automatically with the Pyramix software Installer The Pyramix software uses an automated installer wizard which will install all necessary prerequisites We use a unified installer package containing the current versions of Pyramix VCube and Ovation The initial installer screen offers the choice of Pyramix
28. m 30 Single board system 29 30 Flux VS3 V3 plug ins 19 H Hardware Warranty Information 4 Import Key 21 Increase Scheduling Priority 13 Increase scheduling priority 14 Indexing 16 INFORMATION FOR THE USER 3 Introduction 8 K Keys 22 L Latency modes 28 M MassCore RAVENNA 26 y wn MassCore 64 bit RTX relicencing 25 MassCore and Networks 13 MassCore Network Permissions 13 MassCore Systems 12 MIDI 17 Midi remote controllers 17 MT Security Settings 21 Multi board Installation 18 Mykerinos Card Installation 18 Inserting Audio Board 18 Installation 18 serial number 22 Mykerinos Systems 12 N Native Install 20 O Other Applications 16 P PC Setup 16 Power Management 16 R RAVENNA 26 Recommended options 17 S SafeNet dongle 20 small fonts 16 Software Installation 19 Software Registration 21 STATIC DANGER 18 STATIC DANGER NOTICE 3 System Requirements 12 T Thank you 8 Troubleshooting 32 U UAC 29 User Account Control 29 V Video and Pyramix on one PC 16 VS3 control panel 28 30 Windows Firewall 29 31 Y YourPersonalKey 21 y wn
29. nch Pyramix Please see important information on next page Installation Guide First launch AMERGING a Pyramix DIGITAL AUDIO WORKSTATION Note At the first launch a firewall approval dialog may appear P Windows Security Alert x e Windows Firewall has blocked some features of this program Windows Firewall has blocked some features of Pyramix Virtual Studio Application on all public and private networks Name Pyramix Virtual Studio Application Publisher Merging Technologies S A Path C program files merging technologies pyramix virtual studiolpyramix exe Allow Pyramix Virtual Studio Application to communicate on these networks 7 Private networks such as my home or work network r Public networks such as those in airports and coffee shops not recommended because these networks often have little or no security What are the risks of allowing a proaram through a firewall Windows Security Alert dialog Windows Firewall Click on Allow access since this is necessary to ensure correct VT2 Virtual Transport 2 functioning Note For further information about options available in the VS3 Control Panel please see the Pyramix User Manual Note At first Pyramix launch and or after installing MassCore the following alert box may appear If it does please reboot the computer one more time o MassCore RunTime is not properly configured configuration updated Please rebo
30. ore attempting to launch Pyramix Virtual Studio Then open the VS3 control panel applica tion Start gt All Programs gt Merging Technologies gt VS3 Runtime gt VS3 control panel For Systems with MassCore Follow the instructions above depending on whether you have one or multiple boards fitted with this exception First choose MassCore from the Platform drop down list For Systems with MassCore and RAVENNA Please see Configure RAVENNA in the VS3 Control Panel on page 28 For Pyramix systems with a single Mykerinos board Leave all default selections as they are making sure the On Bus checkbox for your Mykerinos card is indeed checked For now leave all other settings as they are Click on the OK button When the VS3 panel Do you want to save routing dialog box appears click on OK the VS3 control panel will close For Pyramix systems with a multiboard configuration Make sure there is a check mark in the On Bus boxes for each board installed Check that the Application combo box is showing Pyramix Virtual Studio If not select it from the list Select which board is to provide an external Video TC reference with the radio buttons next to the board icons For now leave all other settings as they are Click on the OK button When the VS3 panel Do you want to save routing dialog box appears click on OK the VS3 control panel will close Launch Pyramix Double click on the Pyramix Virtual Studio desktop icon to lau
31. ot the computer VS3 error alert box Documentation The User Manual and Quick Start Guide are available from within Pyramix and may be accessed via the Help menu or by pressing F1 or online at http www merging com downloads y Installation Guide First launch AMERGING a Pyramix DIGITAL AUDIO WORKSTATION 12 Troubleshooting Please visit regularly www merging com for the latest Troubleshooting Guide and FAQ sections 13 Lost or Stolen Merging Technologies Security Keys SafeNet HASP USB Dongles The Merging USB Key carries all the value of your Merging software and the software licence authorization to use it Please ensure you do not lose the USB key as Merging Technologies cannot be held responsible if this is lost or stolen If your USB key is lost or stolen then please make a claim on your insurance in the usual way just as you would for any other item you own Merging will be happy to confirm the details and value of the software licence and USB key to your insurance company If your USB key is lost or stolen and a different user should attempt to register for this key Merging will notify you and the authorities in your country that an attempt has been made to register this stolen item If your USB key should become defective or is broken please ensure this key is returned to Merging after request ing and RMA Return Merchandise Authorization Only after the receipt of this key in the Merging Offices
32. page 11 first If you have purchased Pyramix Virtual Studio as an integrated Turnkey system the installation information in this guide will be redundant since these systems come with all hardware and software pre installed If you are config uring your own system please refer to the following instructions Installation Guide Introduction a Pyramix DIGITAL AUDIO WORKSTATION 2 Pyramix Versions Compatibility and Installation Steps Native ASIO on 3rd party hardware Compatibility Windows 7 Professional 32 bit or 64 bit Installation Steps Pyramix Software Installation See Pyramix Software Installation on page 19 Entering Authorization Keys See Pyramix Software Registration on page 21 Select ASIO and the correct card device in the VS3 Control Panel Start Menu gt Control Panel gt VS3 Control Panel Native with ASIO for RAVENNA and Horus Compatibility Windows 7 Professional 32 bit or 64 bit Installation Steps Install the Merging RAVENNA ASIO Driver provided with your Horus or available from http www merging com download Select ASIO and the correct card device in the VS3 Control Panel Start Menu gt Control Panel gt VS3 Control Panel Optional Pyramix Software Installation See Pyramix Software Installation on page 17 If Pyramix Software is installed Entering Authorization Keys See Pyramix Software Registration on page 19 Select the desired network adapter in Merging RAVENNA ASIO Panel Start
33. s See Pyramix Software Registration on page 19 MassCore Installation See MassCore Installation on page 21 Select MassCore with RAVENNA in the VS3 Control Panel Start Menu gt Control Panel gt VS3 Control Panel Quick Setup Checklist For Systems with Horus MassCore users MUST uninstall the previous MassCore version from the Windows Control Panel Interval Zero RTX runtime MassCore users MUST configure their BIOs settings Please see BIOS Settings on page 16 Disable Windows Firewall in Windows Control Panel Security Increase Scheduling Priority Please see MassCore and Networks on page 13 Install Google Chrome Install Pyramix v9 x or Ovation v4 x Enter your new v9 v4 keys in MT Security Settings Also in MT Security Settings install MassCore from the MassCore Tab yp 9 NO Wh MassCore SMP users recommended for i7 CPU configurations and above should launch the VS3 Control Panel and assign 2 cores to MassCore A reboot will be required Shut down the system and install the MassCore NET MSC GBEX1 PCle Ethernet controller card Card drivers are included in the Pyramix and Ovation installers In the VS3 Control Panel ensure that RAVENNA is selected in the Hardware section Configure the Switch Router if present Please refer to the RAVENNA Network Guide Launch Pyramix You can also launch the MTDiscovery application and double click on the Horus entry for browser remote access Ensure that the Horus is
34. set to the same sampling rate as Pyramix or Ovation A warning prompt will appear if this is not the case Configure I O as required in Pyramix Ovation and Horus RAVENNA users should consult the RAVENNA Easy Connect Guide Installation Guide Pyramix Versions Compatibility and Installation Steps AMERGING a Pyramix DIGITAL AUDIO WORKSTATION 3 For Users Performing Upgrades Note New v9 Keys have been issued for Pyramix v9 users Be aware that 8 x keys will only work with the Beta and Release Candidate versions of Pyramix 9 Pyramix We recommend uninstalling any previous version of Pyramix before installing Pyramix 9 From the Windows Control Panel select Programs and features Remove the installed version of Pyramix VCube Pyramix 9 can coexist with VCube Version 5 Be aware of recommended configurations Masscore MassCore users MUST remove the existing MassCore runtime Once you have installed Pyramix v9 x follow these steps 1 Ensure that you are logged on to your system with the User Account which was used to install MassCore in the first place This information can be retrieved with our MassCore Troubleshooting Guide see below Launch MT Security Settings and select the MassCore tab Click on the Uninstall MassCore Runtime button When the uninstall completes reboot the system After the system reboot return to MT Security Settings and select the MassCore tab Click on the Install MassCore to
35. temperature or operation outside maxi mum rating 2 Products on which warranty stickers or product serial numbers have been removed altered or ren dered illegible 3 The cost of installations removal or reinstallation 4 Damages caused to any other products Installation Guide V9 x a Pyramix DIGITAL AUDIO WORKSTATION Installation Guide V9 x Contents 1 Introduction 8 Thank you Scope 2 Pyramix Versions Compatibility and Installation Steps 9 3 For Users Performing Upgrades 11 4 System Requirements 12 Mykerinos Systems 12 Pyramix MassCore Systems 12 Pyramix Native 13 MassCore and Networks 13 5 PC Setup 16 Motherboard Drivers and Utilities 16 BIOS Settings 16 Display Settings 16 Power Management 16 Aero graphics 16 Indexing 16 Other Applications 16 Video and Pyramix on one PC 16 Recommended options 17 6 Mykerinos Installation 18 Mykerinos Card Installation 18 7 Pyramix Software Installation 19 Installation Overview 19 Driver Signing 19 Flux VS3 V3 plug ins 19 Running the Installer 20 8 Pyramix Software Registration 21 9 MassCore Installation 23 64 Bit MassCore Notes 24 10 MassCore RAVENNA 26 Installing the Merging Technologies NET MSC GBEX1 PCle Ethernet Controller Card 26 Troubleshooting 29 11 First launch 30 12 Troubleshooting 32 13 Lost or Stolen Merging Technologies Security Keys 32 14 Contacting Merging 33 International Office 33 UK 33 USA 33 Installation Guide V9 x Contents AMERGING
36. uter fr Deny log on as a batch job Deny log on as a service Deny log on locally Deny log on through Terminal Enable computer and user Force shutdown from a remote Generate security audits Impersonate a client after authe Increase a process working set Load and unload device drivers Lock pages in memory Log on as a batch job Log on as a service Manage auditing and secunty I Security Setting LOCAL SERVICE Adm Administrators LOCAL SERVICE NET Administrators Administrators Guest ASPNET S 1 5 21 78 ASPNET Administrators LOCAL SERVICE NET LOCAL SERVICE NET Users Administrators ASPNET_ACTUser S ASPNET Administrators 2 Rights Assignment y wn MassCore Windows GPO Editor Window Installation Guide System Requirements Navigate to Computer Configuration gt Windows Settings gt Security Settings gt Local Policies gt User y wn O Pyramix DIGITAL AUDIO WORKSTATION 3 Double click on Increase scheduling priority to open the Increase scheduling priority Properties dialog Increase scheduling priority Properties 550 m L x Local Securty Setting Explain Increase scheduling prionty Increase scheduling priority Properties dialog 4 Clickon the Add User or Group button to open the Select Users or Groups dialog Select this object type Users or Built in security principals From this location M
37. will it be determined if it may be exchanged under warranty free of charge or if the damage is outside the warranty scope in which case only a modest fee to replace it with a new key will be charged and not the entire value of the soft ware Installation Guide Troubleshooting AMERGING Pyramix DIGITAL AUDIO WORKSTATION 14 Contacting Merging International Office Uk USA 7 Merging Technologies S A Le Verney 4 CH 1070 Puidoux Switzerland Phone 41 21 946 0444 Fax 41 21 946 0445 Merging UK Emerging 23 Easter Park Benyon Road Silchester Reading UK RG7 2PQ Phone 44 0 118 402 5090 Fax 44 0 870 1231747 Email salesemerginguk com Merging USA Independent Audio 43 Deerfield Road Portland ME 04101 1805 United States of America Phone 1 207 773 2424 Fax 1 207 773 2422 For all documentation inquiries or suggestions for improvement http www merging com Installation Guide Contacting Merging O Pyramix DIGITAL AUDIO WORKSTATION Index Numerics 64 Bit MassCore Notes 24 A Aero graphics 16 Antivirus 29 B BIOS Settings 16 C CE Notice 3 Changing or re entering a Key 21 Contacting Merging 33 D Digital mixers 17 Display Settings 16 Do you want to save routing 28 30 Driver Signing 19 DUAL 18 E EMC Emissions 3 EMC Immunity 3 Entering Keys 21 F FCC Notice 3 Firewall 29 First launch Multi board syste
Download Pdf Manuals