Home
TOBY-L2 series - U-Blox
Contents
1. GPIO UART ring indicator GPIO UART data carrier detect GPIO UART data terminal ready GPIO UART ready to send UART clear to send Advance Information TOBY L2 series Data Sheet Remarks Leave unconnected All GND pins must be connected to ground 3 0 V typical generated by the module when VCC supply voltage is within valid operating range See section 4 2 2 for detailed electrical specs Note leave unconnected as VUSB_DET functionality is not supported by 00 01 and 50 product versions Input for VBUS 5 V typical USB supply sense See section 4 2 11 for detailed electrical specs 1 8 V typical generated by the module when it is switched on See section 4 2 2 for detailed electrical specs This pin has special function it must be connected to GND to allow module to work properly Leave unconnected Leave unconnected Leave unconnected Note UART DSR not supported by TOBY L200 00S TOBY L210 00S TOBY L200 50S TOBY L210 50S GPIO not supported by 00 01 50 product versions Circuit 107 DSR in ITU T V 24 configurable as GPIO PU PD class H Value at internal reset T PU See section 4 2 12 for detailed electrical specs Note UART RI not supported by TOBY L200 00S and TOBY L210 00S module product versions GPIO not supported by 00 01 50 product versions Circuit 125 RI in ITU T V 24 configurable as GPIO PU PD class H Value a
2. UBX 13004573 R07 Advance Information Appendix Page 43 of 46 b OX TOBY L2 series Data Sheet Related documents 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Le u blox AT Commande Manual Docu No UBX 13002752 u blox TOBY L2 MPCI L2 series System Integration Manual Docu No UBX 13004618 u blox Android RIL Production delivery Application note Docu No UBX 13002041 u blox Windows Embedded RIL Production delivery Application note Docu No UBX 13002043 u blox GNSS Implementation Application Note Docu No UBX 13001849 u blox Mux Implementation Application Note Docu No UBX 13001887 u blox GNSS Implementation Application Note Docu No UBX 13001849 u blox Wi Fi Cellular Integration Application Note Docu No UBX 14003264 u blox Package Information User Guide Docu No UBX 14001652 3GPP TS 27 007 AT command set for User Equipment UE 3GPP TS 27 005 Use of Data Terminal Equipment Data Circuit terminating Equipment DTE DCE interface for Short Message Service SMS and Cell Broadcast Service CBS 3GPP TS 27 010 Terminal Equipment to User Equipment TE UE multiplexer protocol 3GPP TS 26 267 Technical Specification Group Services and System Aspects eCall Data Transfer In band modem solution General description 3GPP TS 36 521 1 Evolved Universal Terrestrial Radio Access User Equipment conformance specification Radio transmis
3. na A L so D az KS wo SG SE oO OO 2 g ZS E L0 lt X 6 u 1892 5 J SISSQTSRSGCEITSSGELZELESE ce BIR S m a T T mn O a UO d 33 o OU d DZ d Do oC o An d 245 850 900 TOBY L200 4 7 17 24 6 AWS 12 Quad IP Ie Soo E ip Se EE EE ars ee i 1900 2100 2 4 5 E TOBY L201 4 13 17 24 6 850 1900 F F F e gt F F F F e F o F o o o F o USCH 850 900 E F TOBY L210 4 7 8 20 24 6 1900 2100 12 Quad IP Ir ip i Ol F F lie OPP ips IP ip e 1 3 5 850 900 TOBY L280 4 7 8 28 24 6 1900 2100 12 Quad F FF ooe FF F e F oe FFF F o e supported by all product versions o supported by all product versions except product version o supported by product version 50 and future product versions F supported by future product versions Table 1 TOBY L2 series main features summary UBX 13004573 RO7 Advance Information Functional description Page 5 of 46 b OX TOBY L2 series Data Sheet 1 3 Block diagram ANT D I PAs po M weoi Eh SH Kl SIM r LNAs Filters 2 d Filters gt gt ES gt H DDC I2C lt _ _ _ _ PAs Filters ar e ES gt s SDIO lt LNAs Filters i Fes Ly gt gt Transceiver Memory lt e VART y Cellular USB Ges LNAs R Ee Base band GPIO smin SE gt E Processor 9 _ gt Le 32 768 kHz Digital a
4. Leave unconnected All GND pins must be connected to ground Leave unconnected All GND pins must be connected to ground Leave unconnected Leave unconnected Leave unconnected Note not supported by 00 01 50 product versions S word alignment otherwise configurable as GPIO PU PD class M Value at internal reset T PD See section 4 2 12 for detailed electrical specs Note not supported by 00 01 50 product versions S transmit data out otherwise configurable as GPIO PU PD class M Value at internal reset T PD See section 4 2 12 for detailed electrical specs Note not supported by 00 01 50 product versions PS serial clock otherwise configurable as GPIO PU PD class M Value at internal reset T PD See section 4 2 12 for detailed electrical specs Note not supported by 00 01 50 product versions PS receive data in otherwise configurable as GPIO PU PD class M Value at internal reset T PD See section 4 2 12 for detailed electrical specs Note not supported by 00 01 50 product versions Fixed open drain No internal pull up Value at internal reset T See section 4 2 13 for detailed electrical specs Note not supported by 00 01 50 product versions Fixed open drain No internal pull up Value at internal reset T See section 4 2 13 for detailed electrical specs See section 4 2
5. Leave unconnected All GND pins must be connected to ground Leave unconnected All GND pins must be connected to ground Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected Leave unconnected Pin definition Page 20 of 46 No 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 Name RSVD GND RSVD GND RSVD RSVD RSVD 125_WA 125_TXD 125_CLK 125_RXD SCL SDA SIM_CLK SIM IO SIM_RST VSIM GPIO5 GPIO6 HOST_SELECT1 SDIO_D2 SDIO_CLK SDIO_CMD UBX 13004573 RO7 Power domain GND GND GDI GDI GDI GDI DDC DDC SIM SIM SIM 1 0 N A N A N A N A N A N A N A VO 1 0 O 1 0 VO 1 0 1 1 0 1 0 1 0 1 0 1 0 1 0 1 0 Description RESERVED pin Ground RESERVED pin Ground RESERVED pin RESERVED pin RESERVED pin PS word alignment GPIO PS transmit data GPIO PS clock GPIO PS receive data GPIO FC bus clock line PC bus data line SIM clock SIM data SIM reset SIM supply output GPIO GPIO Input for the selection of module configuration by the host processor SDIO serial data 2 SDIO serial clock SDIO command Advance Information TOBY L2 series Data Sheet Remarks
6. Notified Body number CE Conformit Europ enne Notified Body number FCC US Federal Communications Commission FCC identification number IC Industry Canada IC certification number Anatel Brazilian Certification RCM Regulatory Compliance Mark Australia NCC National Communications Commission Taiwan KC Korea Certification Giteki Mark Japanese Certification AT amp T Mobile Network Operator Verizon Mobile Network Operator TOBY L200 YES YES YES 1588 YES 1588 YES XPYTOBYL200 YES 8595A TOBYL200 YES YES Table 28 TOBY L2 series main certification approvals summary TOBY L201 YES YES YES 1588 YES 1588 YES XPYTOBYL201 YES 8595A TOBYL201 YES YES TOBY L210 YES YES YES 1588 YES 1588 YES XPYTOBYL210 YES 8595A TOBYL210 YES YES YES YES TOBY L280 YES YES YES 1588 YES 1588 YES XPYTOBYL280 YES 8595A TOBYL280 YES YES For the complete list of approvals and for specific details on all country and network operators certifications see our website www u blox com or please contact the u blox office or sales representative nearest you UBX 13004573 RO7 Advance Information Qualification and approvals Page 35 of 46 b OX TOBY L2 series Data Sheet 7 Product handling amp soldering 7 1 Packaging TOBY L2 series modules are delivered as hermetically sealed reeled tapes to enable efficient production production
7. GND 70 VCC 71 VCC 72 VCC 73 GND 74 GND 75 ANT_DET 76 GND 77 RSVD 78 GND 79 GND 80 GND 81 ANT1 82 GND 83 GND 84 RSVD 85 GND 86 GND 87 ANT2 88 GND 89 GND 90 GND 91 RSVD 92 GND 93 152 GND Table 5 TOBY L2 series pin out Le Le UBX 13004573 RO7 1 0 1 0 1 0 1 0 N A N A N A N A N A N A N A N A 1 0 N A N A N A N A N A N A N A N A N A N A N A Description SDIO serial data 0 SDIO serial data 3 SDIO serial data 1 Ground Module supply input Module supply input Module supply input Ground Ground Antenna detection Ground RESERVED pin Ground Ground Ground Primary antenna Ground Ground RESERVED pin Ground Ground Secondary antenna Ground Ground Ground RESERVED pin Ground Ground TOBY L2 series Data Sheet Remarks Note not supported by 00 01 product versions PU PD class M Value at internal reset T PD See section 4 2 12 for detailed electrical specs Note not supported by 00 01 product versions PU PD class M Value at internal reset T PD See section 4 2 12 for detailed electrical specs Note not supported by 00 01 product versions PU PD class M Value at internal reset T PD See section 4 2 12 for detailed electrical specs All GND pins must be connected to ground All VCC pins must be connected to external supply See sections 4 2
8. for GSM E GSM bands e Power Class E2 26 dBm for DCS PCS bands Data Rate e GPRS multi slot class 12 CS1 CS4 up to 85 6 kb s DI UL e EDGE multi slot class 12 MCS1 MCS9 up to 236 8 kb s DL UL The TOBY L2 series modules support AT commands according to 3GPP standards TS 27 007 10 TS 27 005 11 and the u blox AT command extension Manual 1 For the complete list of all supported AT commands and their syntax see the u blox AT Commands RIL Radio Interface Layer software for Android and Embedded Windows is available for TOBY L2 series modules free of charge see the Android RIL Production delivery 3 and Windows Embedded RIL Production delivery 4 application notes for the supported software deliveries and more information HSDPA category 24 capable gt GPRS EDGE multi slot class determines the number of timeslots available for upload and download and thus the speed at which data can be transmitted and received with higher classes typically allowing faster data transfer rates GPRS EDGE multi slot class 12 implies a maximum of 4 slots in DL reception and 4 slots in UL transmission with 5 slots in total UBX 13004573 RO7 Advance Information Functional description Page 8 of 46 biox TOBY L2 series Data Sheet 1 6 Supported features Table 3 lists the main features supported by TOBY L2 modules For more details see TOBY L2 MPCI L2 series System Integration Manual 2 and u blox AT Com
9. lot set up and tear down For more information about packaging see the u blox Package Information User Guide 9 7 1 1 Reels TOBY L2 series modules are deliverable in quantities of 150 pieces on a reel The modules are delivered using the reel Type B described in the Figure 4 and in the u blox Package Information Guide 9 IN N e al ul it i i 1 HA WI Measured at h vrai Deco CO a a g H DEPRESSION L D 02202 000 J SEH 2 240200 Tape Size Flan mbination Norminal 4 mm ange Combinatio Hub Width W 56 C9F2 C9F2 57mm 57 0 5 0 0 mm 28 5mm 28 5mm NOTE ALL DIMENSIONS IN MILLIMETERS Figure 4 TOBY L2 series modules reel Parameter Specification Reel Type B Delivery Quantity 150 Table 29 Reel information for TOBY L2 series modules Quantities of less than 150 pieces are also available Contact u blox for more information UBX 13004573 RO7 Advance Information Product handling 8 soldering Page 36 of 46 b OX TOBY L2 series Data Sheet 7 1 2 Tapes Figure 5 shows the position and the orientation of TOBY L2 modules as they are delivered on the tape while the Table 30 specifies the tape dimensions Pin 1 Sprocket hole ce 1588 ce 1588 Made in Austria 008 00 a is DO 3 3 os DO Model TOBY L200 870300 0706 000 IMEI 352254060083497 Model TOBY L200 FCC IO xPYTONYL200 IC BREA TOBYL2O0 EH EH Cb biox Sp Feed direc
10. re ete inner ane retenu 25 424 LT E RF characteristics sienne 26 A PP AA ne ae ys 28 42 6 26 RE characteristics edi ee nr en M cs evn Ne re it 29 4 2 7 ANT IDET Dl eege 29 4 2 8 del CR en EENS n de 20 4 2 9 RESET Chen ENEE 30 A KO Mees LL PP CP O 0 A ieee 31 42 11 USB A A Y AA 31 4 2 12 Generic Digital Interfaces pins MN 32 42 13 DDC PC PINS ER CY AA 32 43 Parameters for ATEX applications bise 33 5 Mechanical specifications Cd ecc nnne ennenen annene ennn 34 6 Qualification and approvals tisse 35 6 1 AELA a E E em Ne 35 6 2 Approvals st 35 7 Product handling amp soldering s nn nnnnnnnnrnnnnnnnns 36 7 1 Packaging 0 A ie 36 7 1 1 A A nr ee ee et 36 7 1 2 ADO A de a AN 37 7 2 Moisture Sensitivity Levels oc Me Moca 38 KE ENN e Ee le DEE fito Mil A ee 38 HAs le Let e IEN WEE tn me tintin nn ae tr des andy it ent 38 8 Default settings AO AA 39 9 Labeling and ordering information 40 9 1 dee RC I Teen 40 9 2 Explanation of codes sienne 40 9 2 ORO 1 d el 41 APP anna 42 A amp Lo y GE o A A 42 Related doc ments A 44 Revision MIS TON Venant eee tannins Eaa Eaa 45 Conta GU ee rr nr rr ataa na nin na a ma ntn aa aa na njn mija aaa aaja aa aaa aaia aaia 46 UBX 13004573 R07 Advance Information Contents Page 4 of 46 b OX TOBY L2 series Data Sheet 1 Functional description 1 1 Overview The TOBY L2 series comprises LTE 3G 2G
11. receive TOBY L2 series modules include a UE Power Class 3 3G transmitter see characteristics according to 3GPP TS 34 121 1 15 TOBY L2 series modules 3G receiver characteristics are compliant to 3GPP TS receiver sensitivity performance described in Table 15 Parameter Receiver input sensitivity Band 5 850 MHz Receiver input sensitivity Band 8 900 MHz Receiver input sensitivity Band 4 AWS 1700 MHz Receiver input sensitivity Band 2 1900 MHz Receiver input sensitivity Band 1 2100 MHz Min Typical Max 112 0 112 0 Condition 50 Q source other settings as per 3GPP TS 34 121 1 15 Table 15 3G receiver sensitivity performance UBX 13004573 RO7 Unit Remarks dBm Downlink dBm Downlink dBm Downlink dBm Downlink dBm Downlink Advance Information Table 2 with output power and 34 121 1 15 with 3G conducted RF leve RF leve RF leve RF leve RF leve for R for R for R for R for R C BER lt 0 1 C BER lt 0 1 C BER lt 0 1 C BER lt 0 1 C BER lt 0 1 Electrical specifications Page 28 of 46 b OX TOBY L2 series Data Sheet 4 2 6 2G RF characteristics The 2G bands supported by each TOBY L2 series module are defined in Table 2 while the following Table 16 describes the Transmitting and Receiving frequencies for each 2G band according to 3GPP TS 51 010 1 16 Param
12. to the known position The power saving configuration is by default disabled but it can be enabled and configured using the UPSV AT command When the power saving is enabled the module automatically enters the low power idle mode whenever possible reducing current consumption During idle mode the module processor core runs with the RTC 32 kHz reference clock which is generated by the internal 32 kHz oscillator Allows SMS via embedded IP Multimedia Subsystem Table 3 TOBY L2 series main supported features L u blox is extremely mindful of user privacy When a position is sent to the Celllocate server u blox is unable to track the SIM used or the specific device Not supported by 00 01 and 50 product versions Not supported by 00 and 50 product versions UBX 13004573 RO7 Advance Information Functional description Page 10 of 46 b OX TOBY L2 series Data Sheet 2 Interfaces 2 1 Power management 2 1 1 Module supply input VCC TOBY L2 series modules must be supplied through the VCC pins by a DC power supply Voltage must be stable because during operation the current drawn from VCC can vary significantly based on the power consumption profile of the LTE 3G 2G technologies described in the TOBY L2 MPCI L2 series System Integration Manual 2 2 1 2 RTC supply input output V_BCKP When VCC voltage is within the valid operating range the internal Power Management Un
13. 0 02 0 02 0 8 0 8 mil O Central Pin Height and Width mm 1 1 43 3 mil 0 02 0 02 0 8 0 8 mil P1 Horizontal Edge to Corner Pin Pitch mm 1 1 43 3 mil 0 20 0 20 7 9 7 9 mil P2 Horizontal Edge to Corner Pin Pitch mm 1 25 49 2 mil 0 20 0 20 7 9 7 9 mil P3 Horizontal Edge to Corner Pin Pitch mm 2 85 112 2 mil 0 20 0 20 7 9 7 9 mil Weight Module Weight g lt 7 Table 27 TOBY L2 series dimensions UBX 13004573 RO7 Advance Information Mechanical specifications Page 34 of 46 biox 6 Qualification and approvals 6 1 Reliability tests TOBY L2 series Data Sheet Tests for product family qualifications according to ISO 16750 Road vehicles Environmental conditions and testing for electrical and electronic equipment and appropriate standards 6 2 Approvals Products marked with this lead free symbol on the product label comply with the Directive 2002 95 EC of the European Parliament and the Council on the Restriction of Use of certain Hazardous Substances in Electrical and Electronic Equipment RoHS TOBY L2 series modules are ROHS compliant No natural rubbers hygroscopic materials or materials containing asbestos are employed Table 28 summarizes the main approvals for TOBY L2 series modules Directive Standard Regulatory Operator GCF Global Certification Forum PTCRB PCS Type Certification Review Board R amp TTE Radio and Telecommunications Terminal Equipment EU Directive
14. 01 Band 5 850 MHz D Band 2 1900 MHz TOBY L210 Band 5 850 MHz Band 8 900 MHz Band 2 1900 MHz D Band 1 2100 MHz TOBY L280 Band 5 850 MHz Band 8 900 MHz Band 2 1900 MHz D Band 1 2100 MHz Advance Information 2G GSM GPRS EDGE 3GPP Release 8 Enhanced Data rate GSM Evolution EDGE GSM EGPRS Radio Access GERA Time Division Multiple Access TDMA DL Advanced Rx Performance Phase 1 Band support e TOBY L200 GSM 850 MHz E GSM 900 MHz DCS 1800 MHz PCS 1900 MHz e TOBY L210 GSM 850 MHz E GSM 900 MHz DCS 1800 MHz PCS 1900 MHz e TOBY L280 GSM 850 MHz E GSM 900 MHz DCS 1800 MHz PCS 1900 MHz Functional description Page 7 of 46 NE biox 4G LTE 3G UMTS HSDPA HSUPA LTE Power Class WCDMA HSDPA HSUPA Power Class e Power Class 3 23 dBm e Power Class 3 24 dBm for LTE mode for UMTS HSDPA HSUPA mode Data rate Data Rate e LTE category 4 e TOBY L200 and TOBY L201 up to 150 Mb s DL 50 Mb s UL e HSDPA cat 14 up to 21 Mb s DU e HSUPA cat 6 up to 5 6 Mb s UL e TOBY L210 and TOBY L280 e HSDPA cat 24 up to 42 Mb s DL HSUPA cat 6 up to 5 6 Mb s UL Table 2 TOBY L2 series LTE 3G and 2G characteristics 1 5 AT command support TOBY L2 series Data Sheet 2G GSM GPRS EDGE GSM GPRS GMSK Power Class e Power Class 4 33 dBm for GSM E GSM bands e Power Class 1 30 dBm for DCS PCS bands EDGE 8 PSK Power Class e Power Class E2 27 dBm
15. 10 for detailed electrical specs Internal 4 7 kQ pull up resistor to VSIM See section 4 2 10 for detailed electrical specs See section 4 2 10 for detailed electrical specs VSIM 1 8 V typical or 3 0 V typical generated by the module according to the SIM card chip voltage type See section 4 2 2 for detailed electrical specs Note not supported by 00 01 50 product versions PU PD class M Value at internal reset T PD See section 4 2 12 for detailed electrical specs Note not supported by 00 01 50 product versions PU PD class M Value at internal reset T PD e section 4 2 12 for detailed electrical specs Note not supported by 00 01 50 product versions PU PD class M Value at internal reset T PD e section 4 2 12 for detailed electrical specs Note not supported by 00 01 product versions PU PD class M Value at internal reset T PD e section 4 2 12 for detailed electrical specs H Note not supported by 00 01 product versions PU PD class M Value at internal reset T PD e section 4 2 12 for detailed electrical specs 1 Note not supported by 00 01 product versions PU PD class M Value at internal reset T PD See section 4 2 12 for detailed electrical specs Pin definition Page 21 of 46 No Name 66 SDIO_DO 67 SDIO_D3 68 SDIO_D1 69
16. 2 4 2 3 for detailed electrical specs All VCC pins must be connected to external supply See sections 4 2 2 4 2 3 for detailed electrical specs All VCC pins must be connected to external supply See sections 4 2 2 4 2 3 for detailed electrical specs All GND pins must be connected to ground All GND pins must be connected to ground Note not supported by 00 01 50 product versions All GND pins must be connected to ground Leave unconnected All GND pins must be connected to ground All GND pins must be connected to ground All GND pins must be connected to ground 50 Q nominal characteristic impedance Main Tx Rx antenna interface See section 4 2 4 4 2 5 4 2 6 for details All GND pins must be connected to ground All GND pins must be connected to ground Leave unconnected All GND pins must be connected to ground All GND pins must be connected to ground 50 Q nominal characteristic impedance Rx only for Down Link MIMO 2x2 and Rx diversity See section 4 2 4 4 2 5 4 2 6 for details All GND pins must be connected to ground All GND pins must be connected to ground All GND pins must be connected to ground Leave unconnected All GND pins must be connected to ground All GND pins must be connected to ground For more information about the pin out see the TOBY L2 MPCI L2 series System Integration Manual 2 See Appendix A for an explanation of abbreviations and te
17. 2 cellular modules available for communication between the u blox cellular module and the u blox short range Wi Fi module The AT commands interface is not available on the SDIO interface of TOBY L2 series modules The SDIO interface supports 50 MHz bus clock frequency which allows a data throughput of 200 Mb s For more details regarding the SDIO interface usage and the integration with a u blox Wi Fi module see the TOBY L2 MPCI L2 series System Integration Manual 2 the Wi Fi Cellular Integration Application Note 8 and the Wi Fi AT commands description in the u blox AT Commands Manual 1 2 6 Audio L Audio is not supported by 00 01 and 50 product versions TOBY L2 series modules include a 4 wire FS digital audio interface I2S_TXD 12S_RXD 12S_CLK DS WA that can be configured by AT command to transfer digital audio data with an external device as an audio codec For more details regarding the Va digital audio interface usage and the integration with an external digital audio device as an audio codec see the TOBY L2 MPCI L2 series System Integration Manual 2 and the audio AT commands description in the u blox AT Commands Manual 1 UBX 13004573 RO7 Advance Information Interfaces Page 16 of 46 Le biox 2 7 GPIO TOBY L2 series Data Sheet GPIOs are not supported by 00 01 and 50 modules product version except for o Wireless Wide Area Network status indication configured
18. 6 biox Parameter Receiver i Receiver i Receiver i Band 20 Band 17 700 MHz Band 13 750 MHz nput sensitivity nput sensitivity nput sensitivity 800 MHz Receiver i nput sensitivity Band 5 850 MHz Receiver i nput sensitivity Band 8 900 MHz Receiver Band 4 Receiver Band 3 Receiver Band 2 Receiver input sensitivity 700 MHz input sensitivity 800 MHz input sensitivity 900 MHz input sensitivity Band 1 2100 MHz Receiver input sensitivity Band 7 2600 MHz Condition 50 Q source Throughput gt 95 dual receiver QPSK modulation Other settings as per 3GPP TS 36 521 1 14 Min Typical 103 5 100 5 105 0 102 5 103 0 97 0 109 0 103 0 100 5 110 0 104 5 101 5 109 5 103 5 98 0 110 0 104 5 98 5 110 0 104 0 98 0 104 5 98 5 102 5 97 0 Table 13 LTE receiver sensitivity performance UBX 13004573 RO7 Max Unit dBm dBm dBm dBm dBm dBm dBm dBm dBm dBm dBm dBm dBm dBm dBm dBm dBm dBm dBm dBm dBm dBm dBm dBm dBm Advance Information Remarks Channel bandw Channel bandw Channel bandw Channel bandw Channel bandw Channel bandw Channel bandw Channel bandw Channel bandw Channel bandw Channel bandw Channel bandw Channel bandw Channel bandw Channel bandw Channel bandw Channel bandw Channel bandw Channel bandw Channel
19. 746 Hz odule receive Frequency range Uplink 177 787 Hz odule transmi Band 13750 MHz Downlink 746 756 Hz odule receive Frequency range Uplink 703 748 Hz odule transmi Barid 281730 MHZ Downlink 758 803 Hz odule receive Frequency range Uplink 832 862 Hz odule transmi panid ZO SONMEZ Downlink 791 821 Hz odule receive Frequency range Uplink 824 849 Hz odule transmi Bandis 850 MHz Downlink 869 894 Hz odule receive Frequency range Uplink 880 915 Hz odule transmi Bandia 300M2 Downlink 925 960 Hz odule receive Frequency range Uplink 710 755 Hz Module transmi pence 00M Downlink 2110 2155 Hz odule receive Frequency range Uplink 710 785 Hz odule transmi Band ODM Downlink 805 880 Hz odule receive Frequency range Uplink 850 910 Hz odule transmi Band 2 41300 MHz Downlink 930 1990 Hz odule receive Frequency range Uplink 920 980 Hz odule transmi Band 1 2100 MHz Downlink 2110 2170 Hz odule receive Frequency range Uplink 2500 2570 Hz odule transmi Band 7 2600 MHz Downlink 2620 2690 Hz odule receive Table 12 LTE operating RF frequency bands TOBY L2 series modules include a UE Power Class 3 LTE transmitter see Table 2 with output power and characteristics according to 3GPP TS 36 521 1 14 TOBY L2 series modules LTE receiver characteristics are compliant to 3GPP TS 36 521 1 14 with LTE conducted receiver sensitivity performance described in Table 13 UBX 13004573 RO7 Advance Information Electrical specifications Page 26 of 4
20. 8 x 2 6 mm 150 pcs reel TOBY L210 505 LTE bands 1 3 5 7 8 20 DC HSPA bands 1 2 5 8 E GPRS bands 850 900 1800 1900 module mainly designed for operation in Europe Asia and other countries supporting UART and SDIO interfaces 35 6 x 24 8 x 2 6 mm 150 pcs reel TOBY L280 005 LTE bands 1 3 5 7 8 28 DC HSPA bands 1 2 5 8 E GPRS bands 850 900 1800 1900 module mainly designed for operation in South East Asia and Oceania supporting UART 35 6 x 24 8 x 2 6 mm 150 pcs reel Table 34 Product ordering codes UBX 13004573 RO7 Advance Information Labeling and ordering information Page 41 of 46 TOBY L2 series Data Sheet biox Appendix A Glossary Name Definition 16QAM 16 Quadrature Amplitude Modulation 8 PSK 8 Phase Shift Keying modulation ACM Abstract Control Model ADC Analog to Digital Converter BER Bit Error Rate CDC Communications Device Class CSFB Circuit Switched Fall Back DDC Display Data Channel FC compatible Interface DL Down link Reception DRX Discontinuous Reception ECM Ethernet networking Control Model EDGE Enhanced Data rates for GSM Evolution ERS External Reset Input Signal ESD Electrostatic Discharge FOAT Firmware update Over AT commands FOTA Firmware update Over The Air FW Firmware GDI Generic Digital Interfaces power domain GMSK Gaussian Minimum Shift Keying modulation GND Ground GNS
21. ANT_DET Host Select functions General Purpose Inputs Outputs GPIO TOBY L2 series modules provide 4G LTE 3G WCDMA DC HSPA 2G GSM E GPRS multi mode technology TOBY L200 and TOBY L201 are mainly designed for operation in America TOBY L210 is mainly designed for operation in Europe Asia and other countries TOBY L280 is mainly designed for operation in south east Asia and Oceania 4G LTE 3GPP Release 9 Long Term Evolution LTE Evolved Uni Terrestrial Radio Access E UTRA Frequency Division Duplex FDD DL Multi Input Multi Output MIMO 2 x 2 Band support e TOBY L200 Band 17 700 MHz Band 5 850 MHz Band 4 1700 MHz Band 2 1900 MHz Band 7 2600 MHz e TOBY L201 Band 17 700 MHz Band 13 750 MHz Band 5 850 MHz Band 4 1700 M Band 2 1900 MHz e TOBY L210 Band 20 800 MHz Band 5 850 MHz Band 8 900 MHz Band 3 1800 MHz I N De H Band 1 2100 MHz Band 7 2600 MHz e TOBY L280 Band 28 750 MHz Band 5 850 MHz Band 8 900 MHz D Band 3 1800 MHz Band 1 2100 MHz Band 7 2600 MHz UBX 13004573 RO7 3G UMTS HSDPA HSUPA 3GPP Release 8 Dual Cell HS Packet Access DC HSPA UMTS Terrestrial Radio Access UTRA Frequency Division Duplex FDD DL Rx diversity Band support TOBY L200 Band 5 850 MHz Band 8 900 MHz Band 4 AWS i e 1700 MHz D Band 2 1900 MHz D Band 1 2100 MHz TOBY L2
22. Fi enable Enable disable the supply of the external Wi Fi chip or GPIO1 GPIO4 DSR module connected to the cellular module Wi Fi data ready Sense when the external Wi Fi chip module connected to GPIO3 DTR the cellular module is ready for sending data by the SDIO waking up the cellular module from low power idle mode Wi Fi reset Reset the external Wi Fi chip or module connected to the GPIO3 DCD cellular module Wi Fi power saving Enable disable the low power mode of the external Wi Fi GPIOZ RI chip module connected to the cellular module 32 kHz clock output 32 kHz clock output for an external Wi Fi chip or module GPIO6 Antenna tuning 4 bit tunable antenna control signals mapping the actual 125_RXD 12S_TXD operating RF band over a 4 pin interface provided for the 125_CLK DS WA implementation of external antenna tuning solutions DSR DTR DCD RI DSR UART data set ready output DSR DSR DTR UART data terminal ready input DTR DTR DCD UART data carrier detect output DCD DCD RI UART ring indicator output RI RI General purpose input Input to sense high or low digital level All General purpose output Output to set the high or the low digital level All Pin disabled Tri state with an internal active pull down enabled All Table 4 GPIO custom functions configuration UBX 13004573 R07 Advance Information Interfaces Page 17 of 46 biox 3 Pin definition 3 1 Pin assignment RSVD GND RSVD RSVD RSVD RSVD RS
23. S Global Navigation Satellite System GPIO General Purpose Input Output GPS Global Positioning System GS Global System for Mobile Communication H High HSDPA High Speed Downlink Packet Access HSIC High Speed Inter Chip HSUPA High Speed Uplink Packet Access l nput means that this is an input port of the module PC nter Integrated Circuit Interface PS nter IC Sound Interface IMEI nternational Mobile Equipment Identity IMS P Multimedia Subsystem L Low LGA Land Grid Array LTE Long Term Evolution MBIM obile Broadband Interface Model MIMO ulti Input Multi Output N A Not Applicable NCM Network Control Model O Output means that this is an output port of the module OD Open Drain PCN IN Product Change Notification Information Note PD Pull Down UBX 13004573 RO7 Advance Information Appendix Page 42 of 46 b OX TOBY L2 series Data Sheet Name Definition POS Power On Input Signal PU Pull Up QPSK Quadrature Phase Shift Keying modulation RMC Reference Measurement Channel RMI Reduced Media Independent Interface RNDIS Remote Network Driver Interface Specification SDIO Secure Digital Input Output SIM Subscriber Identity Module T Tristate TBD To Be Defined UART Universal Asynchronous Receiver Transmitter serial interface UL Up link Transmission UMTS Universal Mobile Telecommunications System USB Universal Serial Bus VoLTE Voice over LTE Table 35 Explanation of abbreviations and terms used
24. SVD 34 RSVD 35 RSVD 36 RSVD 37 RSVD 38 RSVD 39 RSVD 40 RSVD 41 RSVD 42 RSVD UBX 13004573 RO7 Power domain GDI GDI POS GDI GDI ERS GDI GDI GDI USB USB GND GND 1 0 N A N A 1 0 1 0 1 0 1 0 1 0 1 0 N A N A N A N A N A N A N A N A N A N A N A N A N A N A Description UART data input UART data output RESERVED pin RESERVED pin Power on input GPIO GPIO External reset input GPIO GPIO Input for the selection of module configuration by the host processor USB Data Line D USB Data Line D RESERVED pin Ground RESERVED pin Ground RESERVED pin RESERVED pin RESERVED pin RESERVED pin RESERVED pin RESERVED pin RESERVED pin RESERVED pin RESERVED pin RESERVED pin Advance Information TOBY L2 series Data Sheet Remarks Note UART TXD not supported by TOBY L200 00S and TOBY L210 00S module product versions Circuit 103 TxD in ITU T V 24 nternal active pull up to V_INT PU PD class M Value at internal reset T PD See section 4 2 12 for detailed electrical specs Note UART RXD not supported by TOBY L200 00S and TOBY L210 00S module product versions Circuit 104 RxD in ITU T V 24 PU PD class M Value at internal reset T PU See section 4 2 12 for detailed electrical specs Leave unconnected Leave unconnected nternal active pull up to VCC enabled See section 4 2 8 for detailed electric
25. System Integration Manual 2 and the u blox AT Commands Manual 1 UUSBCONF AT commana Power Saving AT UPSV 0 Disabled Network registration AT COPS 0 Self network registration Table 31 Default settings UBX 13004573 RO7 Advance Information Default settings Page 39 of 46 b OX TOBY L2 series Data Sheet 9 Labeling and ordering information 9 1 Product labeling The labels of TOBY L2 series series modules include important product information as described in this section Figure 6 illustrates the label of all the TOBY L2 series modules and includes u blox logo production lot Pb free marking product type number IMEI number certification numbers CE marking with the Notified Body number and production country ner 82 xxS 00 Model TOBY xxxx a Se 8XXXXX XXXX 000 ae IMEI XXXXXXXXXXXXXXX XXXXX XXXXXXXXXXX XXXXX XXXXXXXXXXX d 1 588 XXXXX XXXXXXXXXXX Made in Austria o Figure 6 TOBY L2 series module label 9 2 Explanation of codes Three different product code formats are used The Product Name is used in documentation such as this data sheet and identifies all the u blox products independent of packaging and quality grade The Ordering Code includes options and quality while the Type Number includes the hardware and firmware versions Table 32 details these 3 different formats Format Structure Product Name TOBY TGVV Ordering Code TOBY TGVV TTQ Type Number TOBY TGVV TTQ XX Table 32 Product Code F
26. TOBY L2 series LTE DC HSPA EGPRS modules Data Sheet Abstract Technical data sheet describing TOBY L2 series multi mode cellular modules The modules are a complete and cost efficient LTE 3G 2G multi mode solution offering up to 150 Mb s download data rate and up to 50 Mb s upload data rate covering up to six LTEbands up to five WCDMA DC HSPA bands and four GSM EGPRS bands in the compact TOBY form factor www u blox com UBX 13004573 RO7 oc ki uy LU biox biox Document Information Title Subtitle Document type Document number TOBY L2 series LTE DC HSPA EGPRS modules Data Sheet UBX 13004573 Revision and date RO7 Document status Document status explanation Objective Specification Advance Information Early Production Information Production Information Advance Information This document applies to the following products Name TOBY L200 TOBY L201 TOBY L210 TOBY L280 Type number TOBY L200 00S 00 TOBY L200 50S 00 TOBY L201 01S 00 TOBY L210 00S 00 TOBY L210 50S 00 TOBY L280 00S 00 Modem version 09 71 09 71 09 87 09 71 09 71 09 90 TOBY L2 series Data Sheet 29 May 2015 Document contains the final product specification Application version A01 15 A01 57 A01 01 A01 15 A01 57 A01 02 Document contains target values Revised and supplementary data will be published later Document contains data based on early testing Revised and
27. VD RSVD RSVD RSVD RSVD RSVD RSVD GND RSVD BEBE H RSVD RSVD RSVD 125_WA 125_TXD 125_CLK 125_RXD SCL SDA SIM_CLK SIM_IO SIM_RST VSIM GPIO5 GPIO6 HOST_SELECT1 SDIO_D2 SDIO_CLK SDIO_CMD SDIO_DO SDIO_D3 SDIO_D1 GND vcc vcc vcc GND GND ANT_DET 3 a D a N a KI EI w Ki w N BB 3 w e E E El 2 TOBY L2 Top view Pin 93 152 GND 107 R a N Kal FERE iiie v A N _ N N N GND g g GND Figure 2 TOBY L2 series pin assignment top view UBX 13004573 RO7 RSVD Advance Information O GND GND PEE EEE EEEEEEEEEEEEEEEEEEEE TOBY L2 series Data Sheet RSVD USB_D USB_D HOST_SELECTO GPIO4 GPIO3 RESET_N GPIO2 GPIO1 PWR_ON RSVD RSVD RXD TXD CTS RTS DTR DCD RI DSR RSVD RSVD RSVD RSVD V_INT VUSB_DET V_BCKP GND RSVD Pin definition Page 18 of 46 biox No 11 12 13 14 15 Name RSVD GND V_BCKP VUSB_DET V_INT RSVD RSVD RSVD RSVD DSR RI DCD DTR RTS CTS UBX 13004573 RO7 Power domain GND VBUS GDI GDI GDI GDI GDI GDI GDI 1 0 N A N A 1 0 N A N A N A N A O 1 0 O 1 0 O 1 0 1 1 0 Description RESERVED pin Ground RTC supply Input Output VBUS USB detect input Generic Digital Interfaces supply output RESERVED pin RESERVED pin RESERVED pin RESERVED pin UART data set ready
28. al specs Note not supported by 00 01 50 product versions PU PD class M Value at internal reset T PD See section 4 2 12 for detailed electrical specs Note not supported by 00 01 50 product versions PU PD class M Value at internal reset T PD See section 4 2 12 for detailed electrical specs nternal active pull up to VCC enabled See section 4 2 9 for detailed electrical specs Note not supported by 00 01 50 product versions PU PD class M Value at internal reset T PD See section 4 2 12 for detailed electrical specs Note not supported by 00 01 50 product versions PU PD class M Value at internal reset T PD See section 4 2 12 for detailed electrical specs Note not supported by 00 01 50 product versions PU PD class M Value at internal reset T PD See section 4 2 12 for detailed electrical specs 90 Q nominal differential impedance Pull up pull down and series resistors as required by he USB Revision 2 0 specification 18 are part of the USB pin driver and need not be provided externally See section 4 2 11 for detailed electrical specs 90 Q nominal differential impedance Pull up pull down and series resistors as required by he USB Revision 2 0 specification 18 are part of the USB pin driver and need not be provided externally See section 4 2 11 for detailed electrical specs
29. ation 19 for detailed electrical characteristics Parameter Min Internal supply for GDI domain Low level input 0 30 High level input 1 17 Low level output Input output leakage current 500 Clock frequency on SCL Table 24 DDC FC pins characteristics UBX 13004573 RO7 Typical Max 1 80 0 00 100 0 63 2 10 0 45 500 Unit V Vv V V nA kHz Advance Information Remarks Digital I O Interfaces supply V_INT Max value at 2 0 mA OV lt V lt 0 63 V or 1 17 V lt V lt 2 10 V Electrical specifications Page 32 of 46 b OX TOBY L2 series Data Sheet 4 3 Parameters for ATEX applications This section provides useful parameters and information to integrate TOBY L2 series modules in applications intended for use in areas with potentially explosive atmospheres ATEX describing Total internal capacitance and inductance of TOBY L2 series modules see Table 25 Maximum RF output power and voltage at the antenna pin of TOBY L2 series modules see Table 26 L Any specific applicable requirement for the implementation of the apparatus integrating TOBY L2 series modules intended for use in potentially explosive atmospheres must be fulfilled according to the exact applicable standards check the detailed requisites on the pertinent normative for the application as for example the IEC 60079 0 20 IEC 60079 11 21 IEC 60079 26 22 standards L The certification of the application de
30. bandw Channel bandw Channel bandw Channel bandw Channel bandw Channel bandw TOBY L2 series Data Sheet idth 5 MHz idth 10 MHz idth 5 MHz idth 10 MHz idth 5 MHz idth 20 MHz idth 1 4 MHz idth 5 MHz idth 10 MHz idth 1 4 MHz idth MHz idth 10 MHz idth 1 4 MHz idth 5 MHz idth 20 MHz idth 1 4 MHz idth 5 MHz idth 20 MHz idth 1 4 MHz idth 5 MHz idth 20 MHz idth 5 MHz idth 20 MHz idth 5 MHz idth 20 MHz Electrical specifications Page 27 of 46 biox 4 2 5 3G RF characteristics TOBY L2 series Data Sheet The 3G bands supported by each TOBY L2 series module are defined in Table 2 while the following Table 14 describes the Transmitting and Receiving frequencies for each 3G band according to 3GPP TS 34 121 1 15 Parameter Frequency range Band 5 850 MHz Frequency range Band 8 900 MHz Frequency range Band 4 AWS 1700 MHz Frequency range Band 2 1900 MHz Frequency range Band 1 2100 MHz Table 14 3G operating RF frequency bands Uplink Uplink Uplink Uplink Uplink Downli Downli Downli Downli Downli Min Max 824 849 869 894 880 915 925 960 1710 1755 2110 2155 1850 1910 1930 1990 1920 1980 2110 2170 Unit Remarks Hz Module transmi Hz Module receive Hz odule transm Hz Module receive Hz odule transm Hz odule receive Hz Module transm Hz Module receive Hz Module transmit Hz odule
31. d Sides views Parameter Description Typical Tolerance A Module Height mm 35 6 1401 6 mil 0 20 0 20 7 9 7 9 mil B Module Width mm 24 8 976 4 mil 0 20 0 20 7 9 7 9 mil C Module Thickness mm 2 6 102 4 mil 0 27 0 17 10 6 6 7 mil D Horizontal Edge to Lateral Pin Pitch mm 2 4 94 5 mil 0 20 0 20 7 9 7 9 mil E Vertical Edge to Lateral Pin Pitch mm 2 25 88 6 mil 0 20 0 20 7 9 7 9 mil F Edge to Lateral Pin Pitch mm 1 45 57 1 mil 0 20 0 20 7 9 7 9 mil G Lateral Pin to Pin Pitch mm 11 43 3 mil 0 02 0 02 0 8 0 8 mil H1 Lateral Pin Height mm 0 8 31 5 mil 0 02 0 02 0 8 0 8 mil H2 Lateral Pin close to ANT1 and ANT2 Height mm 0 9 35 4 mil 0 02 0 02 0 8 0 8 mil Lateral Pin Width mm 165 59 1 mil 0 02 0 02 0 8 0 8 mil Ji Lateral Pin to Pin Distance mm 0 3 11 8 mil 0 02 0 02 0 8 0 8 mil J2 Lateral Pin to Pin close to ANT Distance mm 0 2 7 9 mil 0 02 0 02 0 8 0 8 mil K Horizontal Edge to Central Pin Pitch mm 3 15 124 0 mil 0 20 0 20 7 9 7 9 mil L Vertical Edge to Central Pin Pitch mm 7 15 281 5 mil 0 20 0 20 7 9 7 9 mil M1 Central Pin to Pin Horizontal Pitch mm 1 8 70 9 mil 0 02 0 02 0 8 0 8 mil M2 Central Pin to Pin Horizontal Pitch mm 5 2 204 7 mil 0 02 0 02 0 8 0 8 mil M3 Central Pin to Pin Horizontal Pitch mm 4 5 177 2 mil 0 02 0 02 0 8 0 8 mil N Central Pin to Pin Vertical Pitch mm 2 1 82 7 mil
32. d operates between the module DCE and the application processor DTE allowing a number of simultaneous sessions over the physical link UART the user can concurrently use AT interface on one MUX channel and data communication on another MUX channel The following virtual channels are defined for more details see the Mux Implementation Application Note 6 Channel 0 control Channel 1 5 AT commands data connection Channel 6 GNSS tunneling Channel 7 SIM Access Profile SAP UBX 13004573 RO7 Advance Information Interfaces Page 14 of 46 b OX TOBY L2 series Data Sheet 2 5 2 USB interface TOBY L2 series modules include a high speed USB 2 0 compliant interface with maximum 480 Mb s data rate representing the main interface for transferring high speed data with a host application processor The module itself acts as a USB device and can be connected to any USB host equipped with compatible drivers The USB_D USB_D lines carry the USB data and signaling providing all the functionalities for the bus attachment configuration enumeration suspension or remote wakeup according to USB 2 0 specification 18 The additional VUSB_DET input is available as an optional feature to sense the host VBUS voltage 5 0 V typical L The VUSB_DET functionality is not supported by 00 01 and 50 product versions the pin should be left unconnected or it should not be driven high by any external device because a hi
33. dle output level High speed data signaling output high level High speed data signaling output low level Chirp J level output differential voltage Chirp K level output differential voltage Table 22 USB pins characteristics UBX 13004573 RO7 Min Typical 4 40 5 00 0 00 100 100 525 10 360 10 700 900 Advance Information Max 5 25 1 30 150 625 500 10 440 10 1100 500 Unit Remarks V V uA mV mV mV mV mV mV mV mV Electrical specifications Page 31 of 46 Le biox 4 2 12 Generic Digital Interfaces pins Parameter Min Internal supply for GDI domain Low level input 0 30 High level input 1 17 Low level output High level output 1 35 Input output leakage current 500 Internal active pull up resistance 30 30 Internal active pull down resistance 30 30 Table 23 GDI pin characteristics 4 2 13 DDC IC pins Typical Max 1 80 0 00 1 80 0 63 2 10 0 45 500 130 180 150 180 TOBY L2 series Data Sheet Remarks Digital I O Interfaces supply V_INT Max value at 2 0 mA Min value at 2 0 mA OV lt V lt 0 63 V or 1 17 V lt V lt 2 10V Pull Up class H Pull Up class M Pull Down class H Pull Down class M The DDC FC interface is not supported by 00 01 and 50 product versions DDC FC lines SCL and SDA are compliant to the I C bus standard mode specification See the lC Bus Specific
34. dvance Information document status Updated module pin 4 definition VUSB_DET instead of RSVD Updated UART GPIOs and SIM detection support Updated receiver sensitivity performance Updated VCC current consumption Updated PWR_ON and RESET_N timings characteristics Added and updated minor electrical characteristics Early Production Information document status Updated VUSB_DET description the VUSB_DET functionality is not supported and the pin should be left unconnected or it should not be driven high Added and updated minor electrical characteristics Added description of TOBY L2xx 50S modules the 50 product version Updated UART SDIO GPIO sections and added consumption figures with USB not connected Extended the document applicability to TOBY L201 01S and TOBY L280 00S Updated status to Advance Information Corrected UART supported functionalities description Added current consumption figures with module in low power idle mode Advance Information Revision history Page 45 of 46 biox Contact For complete contact information visit us at www u blox com u blox Offices North Central and South America u blox America Inc Phone 1 703 483 3180 E mail info_usQu blox com Regional Office West Coast Phone 1 408 573 3640 E mail info_usQu blox com Technical Support Phone 1 703 483 3185 E mail support_us u blox com UBX 13004573 RO7 Headquarters Europe Middle East Africa u blo
35. emperature Supervisor SIM Access Profile SAP In Band Modem Power saving SMS via IMS TOBY L2 series Data Sheet Description Constant monitoring of the module board temperature Warning notification when the temperature approaches an upper or lower predefined threshold Shutdown notified and forced when the temperature value is outside the specified range shutdown suspended in case of an emergency call in progress The Smart Temperature Supervisor feature can be enabled and configured through the USTS AT command LS The sensor measures board temperature which can differ from ambient temperature Allows access and use of a remote SIM card chip instead of the local SIM card chip directly connected to the module SIM interface The module acts as an SAP client establishing a connection and performing data exchange to an SAP server directly connected to the remote SIM The modules provide a dedicated USB SAP channel and dedicated multiplexer SAP channel over UART for communication with the remote SIM card In Band modem solution for eCall and ERA GLONASS emergency call applications over cellular networks implemented according to the 3GPP TS 26 267 specification 13 When activated the in vehicle eCall ERA GLONASS system IVS creates an emergency call carrying both voice and data including vehicle position data directly to the nearest Public Safety Answering Point PSAP to determine whether rescue services should be dispatched
36. eries Data Sheet Contents Contents nn o errr rs trr err fre 3 1 Functional des siennes 5 Ne ne nn men A nette et in den 5 m Ee 5 1 37 ele EE tr 6 1 4 Product AECA Neri anaa a e eree Ahea onssa 7 1 5 AT command support sisi ea gee eeaeee 8 L Supported features und A eta 9 2 Md d WE 11 2 1 POW manage MeN ss nantes A Y AA 11 2 1 1 Module supply input OC 11 2 1 2 RTC supply input output ON BCE r A cnc cnn nc n cnn crac 11 2 1 3 Generic digital interfaces supply output INT 11 22 Antenna INTE ACES n Win TEE 11 2 2 1 A Y A O A 11 2 2 2 Antenna detection sise 11 23 System leet EEN nee et tete end er teed ed aed aed 11 2 3 1 Module POWER sir iii 11 Kee ee EE WEE 12 2 33 MMM oe eee tea era ee 12 2 3 4 Module configuration selection by host processor 12 PE SNe ect sees ee cies prs DEE 13 2 4 1 SIM interface e AU A 13 EES SIM GETACHON Mo TE 13 2 5 Serial COMMUTATION we 13 2 5 1 ERT Met SC de ne ol 13 25 2 SOTO lg 15 2 5 3 DDC PC interface coin enanas 16 2 54 O A E 16 A Miel 16 LA EEE 17 3 Pin definition E 18 Bile dE ellen 18 4 Electrical specifications reos cr RAN 23 4 1 Absolute maximum rating siennes 23 4 1 1 Maximum ES DER id E A te A 23 4 2 Operating conditions sister 24 UBX 13004573 RO7 Advance Information Contents Page 3 of 46 b OX TOBY L2 series Data Sheet 4 2 1 Operating temperature range siens 24 42 2 E ele ele gl 24 4 23 Current CONSUMPTION nm no ter nn nee
37. eter Min Max Unit Remarks Frequency range Uplink 824 849 Hz Module transmi GSM 850 Downlink 869 894 Hz Module receive Frequency range Uplink 880 915 Hz Module transm E GSM 900 Downlink 925 960 Hz odule receive Frequency range Uplink 1710 1785 Hz odule transm DCS 1800 Downlink 1805 1880 Hz odule receive Frequency range Uplink 1850 1910 Hz Module transm PCS 1900 Downlink 1930 1990 Hz Module receive Table 16 2G operating RF frequency bands TOBY L2 series modules include a GMSK Power Class 4 transmitter for GSM E GSM bands GMSK Power Class 1 transmitter for DCS PCS bands 8 PSK Power Class E2 transmitter for all 2G bands see Table 2 with output power and characteristics according to 3GPP TS 51 010 1 16 TOBY L2 series modules 2G receiver characteristics are compliant to 3GPP TS 51 010 1 16 with conducted receiver sensitivity performance described in Table 17 Parameter Min Typical Max Unit Remarks Receiver input sensitivity 110 0 dBm Downlink RF level BER Class Il lt 2 4 GSM 850 E GSM 900 Receiver input sensitivity 109 0 dBm Downlink RF level BER Class Il lt 2 4 DCS 1800 PCS 1900 Condition 50 Q source other settings as per 3GPP TS 51 010 1 16 Table 17 2G receiver sensitivity performance 4 2 7 ANT_DET pin L Antenna detection ANT_DET is not supported by 00 01 and 50 product versions Pin Name Parameter Min Typical Max Unit Remarks ANT_DET Output DC cur
38. gh logic level applied to the pin will represent a module switch on event additional to the ones listed in section 2 3 1 and will prevent reaching the minimum possible consumption with power saving enabled TOBY L2 series modules provide by default the following set of USB functions CDC ACM modem AT commands interface is available over this modem COM port RNDIS network adapter Ethernet over USB connection is available over this network adapter The USB of TOBY L2 series modules can be configured by the AT UUSBCONF command to select different sets of USB functions available in a mutually exclusive way The configured USB profile can thus consist of a specific set of functions with various capabilities and purposes such as CDC ACM for AT commands and data CDC ACM for GNSS tunneling CDC ACM for SIM Access Profile SAP CDC ACM for diagnostic RNDIS for Ethernet over USB CDC ECM for Ethernet over USB CDC NCM for Ethernet over USB MBIM for Ethernet over USB L CDC ACM for GNSS tunneling CDC ACM for SIM Access Profile SAP CDC NCM and MBIM are not supported by 00 01 and 50 product versions For more details regarding the USB configurations and capabilities see the TOBY L2 MPCI L2 series System Integration Manual 2 and the u blox AT Commands Manual 1 UUSBCONF AT command USB drivers are available for the following operating system platforms Windows Vista Windows 7 Windows 8 Windows 8 1 Windows Embedded Com
39. he external SIM card chip The electrical characteristics fulfill regulatory specification requirements The values in Table 21 are for information only Parameter Min Low level input 0 30 0 30 High level input 1 17 2 00 Low level output High level output 1 35 2 60 Input Output leakage current 500 Clock frequency on SIM_CLK Internal pull up resistor on SM IO Table 21 SIM pins characteristics 4 2 11 USB pins Typical Max Unit 0 63 V 0 80 V 2 10 V 3 30 V 0 00 0 45 V 0 00 0 40 V 1 80 V 2 90 V 500 nA 3 25 MHz 4 7 kQ Remarks VSIM 1 8 V VSIM 3 0 V VSIM 1 8 V VSIM 3 0 V VSIM 1 8 V Max value at 2 0 mA VSIM 3 0 V Max value at 2 0 mA VSIM 1 8 V Min value at 2 0 mA VSIM 3 0 V Min value at 2 0 mA 0OV lt V lt 0 63V or 1 17 V lt V lt 2 10V O V lt V lt 0 80 V or 2 00 V lt V lt 3 30 V Internal pull up to VSIM supply USB data lines USB_D USB_D are compliant to the USB 2 0 high speed specification See the Universal Serial Bus Revision 2 0 specification 18 for detailed electrical characteristics Parameter VUSB_DET pin High level input VUSB_DET pin Low level input VUSB_DET pin Current sink High speed squelch detection threshold input differential signal amplitude a High speed disconnect detection threshold input differential signal amplitude High speed data signaling input common mode voltage range High speed i
40. hutdown occurs on TOBY L2 series modules when a low level is applied on the RESET_N pin which is normally set high by an internal pull up for a valid time period see the section 4 2 9 This causes an abrupt shutdown of the module the current parameter settings are not saved in the module s non volatile memory and a proper network detach is not performed An over temperature or an under temperature shutdown occurs on TOBY L2 modules when the temperature measured within the cellular module reaches the dangerous area if the optional Smart Temperature Supervisor feature is enabled and configured by the dedicated AT command For more details see the TOBY L2 MPCI L2 series System Integration Manual 2 and the u blox AT Commands Manual 1 USTS AT command L Smart Temperature Supervisor is not supported by 001 01 and 50 product versions 2 3 3 Module reset TOBY L2 series modules can be reset rebooted by AT CFUN command see the u blox AT Commands Manual Dh This causes an internal or software reset of the module The current parameter settings are saved in the module s non volatile memory and a proper network detach is performed An abrupt external or hardware reset occurs when a low level is applied to the RESET_N pin which is normally set high by an internal pull up for a valid time period see the section 4 2 9 This causes an external or hardware reset of the module The current para
41. ication FW update by means of the FOAT feature and for diagnostic purpose UART features are Complete serial port with RS 232 functionality conforming to the ITU T V 24 Recommendation 17 with CMOS compatible signal levels 0 V for low data bit or ON state and 1 8 V for high data bit or OFF state Data lines RXD as output TXD as input hardware flow control lines CTS as output RTS as input modem status and control lines DTR as input DSR as output DCD as output RI as output are provided Hardware flow control default value software flow control or none flow control are supported L Software flow control is not supported by 00 01 and 50 module product versions UBX 13004573 RO7 Advance Information Interfaces Page 13 of 46 b OX TOBY L2 series Data Sheet Power saving indication available on the hardware flow control output CTS line the line is driven to the OFF state when the module is not prepared to accept data by the UART interface Power saving control over the RTS input or the DSR input can be enabled via AT UPSV command for more details see u blox AT Commands Manual 1 and TOBY L2 MPCI L2 series System Integration Manual 2 The following baud rates are supported 9600 19200 38400 57600 115200 default baud rate when autobauding is disabled or not supported 230400 460800 and 921600 b s One shot autobauding is supported and it is by default enabled automatic baud rate detec
42. iod Maximum 340 mA 2G GMSK call 1 Tx 1 Rx slot 850 900 MHz Averaged current value over a 10 second period Maximum 280 mA 2G GMSK call 1 Tx 1 Rx slot 1800 1900 MHz 3G Connected Mode Averaged current value over a 10 second period 55 dBm 250 mA Tx Rx call enabled 3G call with Low data rate 0 dBm 265 mA 12 dBm 350 mA 18 dBm 460 mA Maximum 600 mA Averaged current value over a 10 second period Maximum 640 mA 3G call with Maximum data rate LTE Connected Mode Averaged current value over a 10 second period 55 dBm 295 mA Tx Rx call enabled LTE call with Low data rate 0 dBm 310 mA 12 dBm 390 mA 18 dBm 490 mA Maximum 610 mA Averaged current value over a 10 second period Maximum 660 mA LTE call with Maximum data rate Table 11 Module VCC current consumption Typical values with a matched antenna Maximum values with a mismatched antenna Y It is recommended to use this figure to dimension maximum current capability of power supply UBX 13004573 R07 Advance Information Electrical specifications Page 25 of 46 b OX TOBY L2 series Data Sheet 4 2 4 LTERF characteristics The LTE bands supported by each TOBY L2 series module are defined in Table 2 while the following Table 12 describes the Transmitting and Receiving frequencies for each LTE band according to 3GPP TS 36 521 1 14 Parameter Min Max Unit Remarks Frequency range Uplink 704 716 Hz odule transmi a Downlink 734
43. it PMU supplies the Real Time Clock RTC and the same supply voltage is available on the V_BCKP pin H the VCC voltage is under the minimum operating limit e g during not powered mode the V_BCKP pin can externally supply the RTC 2 1 3 Generic digital interfaces supply output V_INT TOBY L2 series modules provide a 1 8 V supply rail output on the V_INT pin which is internally generated when the module is switched on The same voltage domain is used internally to supply the generic digital interfaces of the modules The V_INT supply output can be used in place of an external discrete regulator 2 2 Antenna interfaces 2 2 1 Antenna RF interfaces The modules have two RF pins with a characteristic impedance of 50 Q The primary antenna pin ANT1 supports both Tx and Rx providing the main antenna interface while the secondary antenna pin ANT2 supports Rx only for the LTE MIMO 2x2 and 3G Rx diversity configurations 2 2 2 Antenna detection L The antenna detection is not supported by 00 01 and 50 product versions The ANT_DET pin is an Analog to Digital Converter ADC input with a current source provided by TOBY L2 modules to sense the antenna presence as an optional feature It evaluates the resistance from ANT1 and ANT2 pins to GND by means of an external antenna detection circuit implemented on the application board For more details see the TOBY L2 MPCI L2 series System Integration Manual 2 and the u b
44. lox AT Commands Manual 1 2 3 System functions 2 3 1 Module power on TOBY L2 series can be switched on in one of the following ways Rising edge on the VCC pin to a valid voltage for module supply i e applying module supply Low level on the PWR_ON pin which is normally set high by an internal pull up for a valid time period when the applied VCC voltage is within the valid operating range see section 4 2 8 The PWR_ON line should be driven by open drain open collector or contact switch UBX 13004573 RO7 Advance Information Interfaces Page 11 of 46 b OX TOBY L2 series Data Sheet Low level on the RESET_N pin which is normally set high by an internal pull up for a valid time period when the applied VCC voltage is within the valid operating range see section 4 2 9 The RESET_N line should be driven by open drain open collector or contact switch RTC alarm i e pre programmed scheduled time by AT CALA command 2 3 2 Module power off TOBY L2 series can be properly switched off by AT CPWROFF command see the u blox AT Commands Manual 1 The current parameter settings are saved in the module s non volatile memory and a proper network detach is performed An abrupt under voltage shutdown occurs on TOBY L2 series modules when the VCC supply is removed If this occurs it is not possible to store the current parameter settings in the module s non volatile memory or to perform the proper network detach An abrupt s
45. mands Manual 1 Feature Network Indication Antenna Detection Jamming detection Embedded TCP and UDP stack FTP FTPS HTTP HTTPS GNSS via modem Embedded AssistNow Software Celllocate Hybrid Positioning Wi Fi via modem Firmware update Over AT commands FOAT Firmware update Over The Air FOTA LTE DL MIMO 2x2 and 3G DL Rx Diversity Description GPIO configured to indicate the network status registered home network registered roaming voice or data call enabled no service The feature can be enabled through the UGPIOC AT command The ANT_DET pin provides antenna presence detection capability evaluating the resistance from ANT1 and ANT2 pins to GND by means of an external antenna detection circuit implemented on the application board The antenna detection feature can be enabled through the UANTR AT command Detects artificial interference that obscures the operator s carriers entitled to give access to the radio service and reports the start and stop of such conditions to the application processor AP The AP can react appropriately by e g switching off the radio transceiver to reduce power consumption and monitoring the environment at regular intervals The feature can be enabled and configured through the UCD AT command Embedded TCP IP and UDP IP stack including direct link mode for TCP and UDP sockets Sockets can be set in Direct Link mode to establish a tra
46. meter settings are not saved in the module s non volatile memory and a proper network detach is not performed The RESET_N line should be driven by open drain open collector or contact switch H 2 3 4 Module configuration selection by host processor L The selection of the module configuration by the host application processor over HOST_SELECTO and HOST_SELECT1 pins is not supported by 00 01 and 50 product versions TOBY L2 series modules include two input pins HOST_SELECTO HOST_SELECT1 for the selection of the module configuration by the host application processor UBX 13004573 RO7 Advance Information Interfaces Page 12 of 46 Qb OX TOBY L2 series Data Sheet 2 4 SIM 2 4 1 SIM interface A SIM card interface is provided on the VSIM SIM_IO SIM_CLK SIM_RST pins the high speed SIM ME interface is implemented as well as the automatic detection of the required SIM supporting voltage Both 1 8 V and 3 V SIM types are supported 1 8 V and 3 V ME Activation and deactivation with automatic voltage switch from 1 8 V to 3 V is implemented according to ISO IEC 7816 3 specifications The SIM driver supports the PPS procedure for baud rate selection according to the values proposed by the SIM card chip 2 4 2 SIM detection L The SIM detection is not supported by 00 01 and 50 product versions TOBY L2 series modules provide the SIM detection function over GPIO to sense the SIM card physical p
47. multi mode modules in the very small LGA form factor 35 6 x 24 8 mm that are easy to integrate in compact designs TOBY L2 series modules support up to six LTE bands five UMTS DC HSPA bands and four GSM E GPRS bands for voice and or data transmission TOBY L2 series modules are form factor compatible with the other popular u blox cellular module families this allows customers to take the maximum advantage of their hardware and software investments and provides very short time to market With LTE category 4 data rates at up to 150 Mb s downlink and 50 Mb s uplink the modules are ideal for applications requiring the highest data rates and high speed internet access TOBY L2 series modules are the perfect choice for consumer fixed wireless terminals mobile routers and gateways and applications requiring video streaming They are also optimally suited for industrial M2M applications such as remote access to video cameras digital signage telehealth and security and surveillance systems 1 2 Product features Module LTE UMTS GSM Positioning Interfaces Audio Features Grade a x o gt gei o Lo Val 2 zo GG E Yoo gt E e 5838582 e a 2 gt 5 oe ix Oe O y Si gt amp E 5 8 8 o So o Z g gt Kal oO 00 lt lt De I a B ZS S D E zs D GE 2 oO o o lt S Dm UO O g on 2 5 ng D ei Gei cs a uu O o 2 2 y os Li os PSS o H a un lt lt vu vu A 5 N Y ul slo O e SM
48. nsitive electronic circuitry and are Electrostatic Sensitive Devices ESD Handling TOBY L2 series modules without proper ESD protection may destroy or damage them permanently TOBY L2 series modules are Electrostatic Sensitive Devices ESD and require special ESD precautions typically applied to ESD sensitive components Table 7 reports the maximum ESD ratings of the TOBY L2 series modules Proper ESD handling and packaging procedures must be applied throughout the processing handling and operation of any application that incorporates TOBY L2 series module ESD precautions should be implemented on the application board where the module is mounted as described in the TOBY L2 MPCI L2 series System Integration Manual 2 Failure to observe these recommendations can result in severe damage to the device UBX 13004573 RO7 Advance Information Product handling amp soldering Page 38 of 46 b OX TOBY L2 series Data Sheet 8 Default settings Item AT Settings Comments USB interface Enabled TOBY L2 series modules provide by default the following set of USB functions CDC ACM for AT command and data RNDIS for Ethernet over USB connection The USB can be configured by the AT UUSBCONF command to select different sets of USB functions available in mutually exclusive way configuring the active USB profile consisting of a specific set of functions with various capabilities and purposes for more details see the TOBY L2 MPCI L2 series
49. nsparent end to end communication with an already connected TCP or UDP socket via serial interface File Transfer Protocol as well as Secure File Transfer Protocol SSL encryption of FTP control channel functionalities are supported via AT command s Hyper Text Transfer Protocol as well as Secure Hyper Text Transfer Protocol SSL encryption functionalities are supported via AT commands HEAD GET POST DELETE and PUT operations are available Full access to u blox positioning chips and modules is available through a dedicated DDC IC interface This means that from any host processor a single serial port can control the cellular module and the positioning chip or module For more details see the GNSS Implementation Application Note 5 Embedded AssistNow Online and AssistNow Offline clients are available to provide better GNSS performance and faster Time to First Fix An AT command can enable disable the clients Enables the estimation of device position based on the parameters of the mobile network cells visible to the specific device based on the CellLocate database Normal scan only the parameters of the visible home network cells are sent Deep scan the parameters of all surrounding cells of all mobile operators are sent CellLocate is available via a set of AT commands for CellLocate service configuration and position request The current module position is provided by a u blox positioning chip or module or the estimated posi
50. on GPIO1 of 00 and 01 product versions o Wi Fi enable function configured on the GPIO1 of 50 product version TOBY L2 series modules include 14 pins GPIO1 GPIO6 125 TXD 12S_RXD DS LK DS WA DTR DSR DCD RI that can be configured as general purpose input output or to provide custom functions as summarized in Table 4 for further details see the TOBY L2 MPCI L2 series System Integration Manual 2 and the u blox AT Commands Manual Dh Function Network status indication GNSS supply enable GNSS data ready GNSS RTC sharing SIM card detection SIM card hot insertion removal PS digital audio Description Network status registered home network registered roaming data transmission no service Enable disable the supply of u blox GNSS receiver connected to the cellular module Sense when u blox GNSS receiver connected to the module is ready for sending data by the DDC FC Real Time Clock synchronization signal to u blox GNSS receiver connected to the cellular module SIM card physical presence detection SIM card hot insertion removal PS digital audio interface Default GPIO GPIO1 GPIO2 GPIO3 GPIO4 GPIO5 125_RXD 125_TXD Configurable GPIOs GPIO1 GPIO2 GPIO3 GPIO4 GPIO5 GPIO5 125_RXD 12S_TXD interface 125_CLK DS WA 12S_CLK DS WA 26 MHz clock output 26 Mhz clock output for an external audio codec or an GPIO6 GPIO6 external Wi Fi chip module Wi
51. ormats Table 33 explains the parts of the product code UBX 13004573 RO7 Advance Information Labeling and ordering information Page 40 of 46 b OX TOBY L2 series Data Sheet Code Meaning Example TOBY Form factor TOBY TG Platform Technology and Generation L2 Technology G GSM U HSUPA L LTE C CDMA 1xRTT D EV DO Generation 1 9 VV Variant function set based on the same platform 00 99 00 TT Major product version 00 99 00 Q Quality grade S S professional A automotive XX Minor product version not relevant for certification Default value is 00 Table 33 Part identification code 9 3 Ordering information Ordering No Product TOBY L200 005 LTE bands 2 4 5 7 17 DC HSPA bands 1 2 4 5 8 E GPRS bands 850 900 1800 1900 module mainly designed for operation in America 35 6 x 24 8 x 2 6 mm 150 pcs reel TOBY L200 505 LTE bands 2 4 5 7 17 DC HSPA bands 1 2 4 5 8 E GPRS bands 850 900 1800 1900 module mainly designed for operation in America supporting UART and SDIO interfaces 35 6 x 24 8 x 2 6 mm 150 pcs reel TOBY L201 01S LTE bands 2 4 5 13 17 DC HSPA bands 2 5 module mainly designed for operation in America supporting UART and embedded TCP UDP HTTP FTP 35 6 x 24 8 x 2 6 mm 150 pcs reel TOBY L210 005 LTE bands 1 3 5 7 8 20 DC HSPA bands 1 2 5 8 E GPRS bands 850 900 1800 1900 module mainly designed for operation in Europe Asia and other countries 35 6 x 24
52. pact 7 TOBY L2 series modules are compatible with standard Linux Android USB kernel drivers UBX 13004573 RO7 Advance Information Interfaces Page 15 of 46 b OX TOBY L2 series Data Sheet 2 5 3 DDC IC interface L The DDC FC interface is not supported by 00 01 and 50 product versions TOBY L2 series modules include an FC bus compatible DDC interface SDA SCL available to communicate with a u blox GNSS receiver and with external UC devices as an audio codec the TOBY L2 module acts as an VC master which can communicate with IC slaves in accordance with the UC bus specifications 19 For more details regarding the DDC FC interface usage and the integration with a u blox GNSS receiver see the TOBY L2 MPCI L2 series System Integration Manual 2 the GNSS Implementation Application Note 7 and the FC and GNSS AT commands description in the u blox AT Commands Manual 1 2 5 4 SDIO interface L The SDIO interface is not supported by 00 01 modules product versions TOBY L2 series modules include a 4 bit Secure Digital Input Output interface SDIO_DO SDIO_D1 SDIO_D2 SDIO_D3 SDIO_CLK SDIO_CMD designed to communicate with an external u blox short range Wi Fi module the TOBY L2 cellular module acts as an SDIO host controller which can communicate over the SDIO bus with a compatible u blox short range Wi Fi module acting as SDIO device The SDIO interface is the only one interface of TOBY L
53. perature range Parameter Min Typical Max Unit Remarks Normal operating temperature 20 25 65 SE Normal operating temperature range fully functional and meet 3GPP specifications Extended operating temperature 40 85 Extended operating temperature range Occasional deviations from 3GPP specifications may occur though the module is functional Table 8 Environmental conditions 4 2 2 Supply power pins Symbol Parameter Min Typical VCC Module supply normal operating input voltage 3 40 3 80 Module supply extended operating input voltage 3 20 3 80 V_BCKP Real Time Clock supply input voltage 1 4 _BCKP Real Time Clock supply average current consumption 2 at V_BCKP 1 8 V Table 9 Input characteristics of Supply Power pins Symbol Parameter Min Typical VSIM SIM supply output voltage 1 76 1 80 2 84 2 90 V_BCKP Real Time Clock supply output voltage 3 00 _BCKP Real Time Clock supply output current capability V_INT Generic Digital Interfaces supply output voltage 1 76 1 80 V_INT_RIPPLE Generic Digital Interfaces supply output voltage ripple LINT Generic Digital Interfaces supply output current capability Table 10 Output characteristics of Supply Power pins Max 4 35 4 35 4 2 Max 1 85 2 94 1 85 45 70 Input voltage at VCC must be above the normal operating range minimum limit to switch on the module Occasional deviations from the 3GPP specifications may occur Ensure that input vol
54. rent 26 UA Generated by means of the AT UANTR pulse value command Output DC current 3 6 ms Generated by means of the AT UANTR pulse time length command Table 18 ANT_DET pin characteristics UBX 13004573 RO7 Advance Information Electrical specifications Page 29 of 46 biox 4 2 8 PWR ON pin Pin Name Parameter PWR_ON nternal supply for Power On Input Signal Low level input High level input Pull up resistance Low level input current PWR_ON low time Table 19 PWR_ON pin characteristics 4 2 9 RESET_N pin Pin Name Parameter RESET_N Internal supply for External Reset Input Signal Low level input High level input Pull up resistance Low level input current RESET_N low time Table 20 RESET_N pin characteristics UBX 13004573 RO7 Min 0 0 7 VCC 35 Min 0 0 7 VCC 35 18 2 1 16 Typical Max 3 8 0 3 VCC VCC 50 76 Typical Max 3 8 0 3 VCC VCC 50 76 800 15 Advance Information Unit kQ pA ms Unit kQ uA ms TOBY L2 series Data Sheet Remarks Module supply input VCC Internal active pull up to VCC Low time to switch on the module Remarks Module supply input VCC Internal active pull up to VCC Low time to switch on the module Low time to reset the module Low time to switch off the module Electrical specifications Page 30 of 46 biox 4 2 10 SIM pins TOBY L2 series Data Sheet The SIM pins are a dedicated interface to t
55. resence las an optional feature when the specific GPIO pin of the module is properly connected to the mechanical switch of the SIM car holder for more details see the TOBY L2 MPCI L2 series System Integration Manual 2 2 5 Serial communication TOBY L2 series provides the following serial communication interfaces UART interface asynchronous serial interface available for the communication with a DTE host application processor AT commands data communication FW update by means of FOAT and for diagnostic USB interface High Speed USB 2 0 compliant interface available for the communication with a USB host application processor AT commands data communication FW update by means of the FOAT feature for FW update by means of the u blox EasyFlash tool and for diagnostic DDC interface UC bus compatible interface available for the communication with u blox GNSS positioning chips modules and with external I C devices as an audio codec SDIO interface Secure Digital Input Output interface available for the communication with an external Wi Fi chip or module 2 5 1 UART interface L The UART interface is not supported by TOBY L200 00S and TOBY L210 00S modules versions L The DTR DSR and DCD signals are not supported by TOBY L200 50S TOBY L210 50S modules versions TOBY L2 series modules include a 9 wire unbalanced asynchronous serial interface UART for communication with an application host processor AT commands data commun
56. rms used Advance Information Pin definition Page 22 of 46 biox 4 Electrical specifications Stressing the device above one or more of the ratings listed in the Absolute Maximum Rating section may cause permanent damage These are stress ratings only Operating the module at these or at any conditions other than those specified in the Operating Conditions sections section 4 2 of the specification should be avoided Exposure to Absolute Maximum Rating conditions for extended periods may affect device reliability TOBY L2 series Data Sheet L Operating condition ranges define those limits within which the functionality of the device is guaranteed L Where application information is given it is advisory only and does not form part of the specification 4 1 Absolute maximum rating L Limiting values given below are in accordance with the Absolute Maximum Rating System IEC 134 Symbol Description Condition Min Max Unit VCC odule supply voltage Input DC voltage at VCC pin 0 3 6 0 V V_BCKP RTC supply voltage Input DC voltage at V_BCKP pin 0 3 6 0 V USB USB D D pins Input DC voltage at USB interface pins 3 6 V GDI Generic digital interfaces Input DC voltage at Generic digital interfaces pins 2 2 V DDC DDC interface Input DC voltage at DDC interface pins 2 2 V SIM SIM interface Input DC voltage at SIM interface pins 0 3 3 6 V ERS External reset signal Input DC voltage at RESET_N pin 0 3 6 0 V POS Po
57. sion and reception Part 1 Conformance Testing 3GPP TS 34 121 1 User Equipment conformance specification Radio transmission and reception FDD Part 1 Conformance specification 3GPP TS 51 010 1 Mobile Station conformance specification Part 1 Conformance specification ITU T Recommendation V24 02 2000 List of definitions for interchange circuits between Data Terminal Equipment DTE and Data Connection Equipment DCE Universal Serial Bus Revision 2 0 specification http www usb org developers docs usb20_docs TC bus specification and user manual Rev 5 9 October 2012 NXP Semiconductors http www nxp com documents user_manual UM10204 paf IEC 60079 0 Explosive atmospheres Part 0 Equipment general requirements IEC 60079 11 Explosive atmospheres Part 11 Equipment protection by intrinsic safety i IEC 60079 26 Explosive atmospheres Part 26 Equipment with EPL Ga For regular updates to u blox documentation and to receive product change notifications please register on our homepage www u blox com UBX 13004573 RO7 Advance Information Related documents Page 44 of 46 biox Revision history Revision RO1 RO2 RO3 RO4 RO5 RO6 RO7 Date 02 Dec 2013 23 Jul 2014 30 Sep 2014 28 Nov 2014 30 Jan 2015 04 Mar 2015 29 May 2015 UBX 13004573 RO7 Name jpod sses sses sses sses sses sfal sses TOBY L2 series Data Sheet Status Comments Initial release A
58. supplementary data will be published later Document contains data from product verification Revised and supplementary data may be published later PCN IN UBX 14044437 UBX 15004131 UBX 15016217 UBX 14044437 UBX 15004131 UBX 15016802 u blox reserves all rights to this document and the information contained herein Products names logos and designs described herein may in whole or in part be subject to intellectual property rights Reproduction use modification or disclosure to third parties of this document or any part thereof without the express permission of u blox is strictly prohibited The information contained herein is provided as is and u blox assumes no liability for the use of the information No warranty either express or implied is given including but not limited with respect to the accuracy correctness reliability and fitness for a particular purpose of the information This document may be revised by u blox at any time For most recent documents please visit www u blox com Copyright O 2015 u blox AG u blox is a registered trademark of u blox Holding AG in the EU and other countries Trademark Notice Microsoft and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United States and or other countries All other registered trademarks or trademarks mentioned in this document are property of their respective owners UBX 13004573 RO7 Page 2 of 46 b OX TOBY L2 s
59. t internal reset T PD See section 4 2 12 for detailed electrical specs Note UART DCD not supported by TOBY L200 00S TOBY L210 00S TOBY L200 50S TOBY L210 50S GPIO not supported by 00 01 50 product versions Circuit 109 DCD in ITU T V 24 configurable as GPIO PU PD class H Value at internal reset T PU See section 4 2 12 for detailed electrical specs Note UART DTR not supported by TOBY L200 00S TOBY L210 00S TOBY L200 50S TOBY L210 505 GPIO not supported by 00 01 50 product versions Circuit 108 2 DTR in ITU T V 24 configurable as GPIO nternal active pull up to V_INT when set as DTR PU PD class H Value at internal reset T PD See section 4 2 12 for detailed electrical specs Note UART RTS not supported by TOBY L200 00S and TOBY L210 00S module product versions Circuit 105 RTS in ITU T V 24 nternal active pull up to V_INT PU PD class H Value at internal reset T PU See section 4 2 12 for detailed electrical specs Note UART CTS not supported by TOBY L200 00S and TOBY L210 00S module product versions Circuit 106 CTS in ITU T V 24 PU PD class H Value at internal reset T PU See section 4 2 12 for detailed electrical specs Pin definition Page 19 of 46 No Name 16 TXD 17 RXD 18 RSVD 19 RSVD 20 PWR_ON 21 GPIO1 22 GPIO2 23 RESET_N 24 GPIO3 25 GPIO4 26 HOST_SELECTO 27 USB_D 28 USB_D 29 RSVD 30 GND 31 RSVD 32 GND 33 R
60. tage at VCC never drops below the extended operating range minimum limit during module operation the cellular module may switch off when the VCC voltage value drops below the extended operating range minimum limit UBX 13004573 RO7 Advance Information Unit A Unit mA mVpp mA Electrical specifications Page 24 of 46 b OX TOBY L2 series Data Sheet 4 2 3 Current consumption Mode Condition Tx power Min Typ Max Unit Power Off Mode Averaged current value over a any period 15 UA odule switched off Idle Mode Averaged current value over a 100 ms period 1 1 mA Power Saving enabled by AT UPSV USB not connected module in low power idle mode a equivalent to CFUN 4 or COPS 2 Averaged current value over a 100 ms period 1 3 mA USB connected and suspended Cyclic Idle Active Mode Averaged current value over a 10 minute period 2 7 mA Power Saving enabled by AT UPSV USB not connected Module registered with network 8 Averaged current value over a 10 minute period 2 9 mA USB connected and suspended Active Mode Averaged current value over a 10 minute period 35 mA Power Saving disabled by AT UPSV USB not connected Module registered with network Averaged current value over a 10 minute period 44 mA USB connected and not suspended 2G Connected Mode Pulse current during a 1 slot GMSK Tx burst Maximum 1 9 2 5 A Tx Rx call enabled 850 900 MHz bands Averaged current value over a 10 second per
61. tion gt Figure 5 Orientation for TOBY L2 modules on tape 21 5 0 1 E 0 12 80 15 0 1 ebe gelies B _0 3 0 05 i Ree ECK SA 4 amp amp 6 00 Ki e OO OO 2i l 2 e ei A ES 8 Mi 2 i i SOO FSSOOOOOO4 O99 00000000000 X B BB 28 0 Vu 40 1 2 D2 0 1 21 5 0 N A or oe O N LG oO i 1 lt AO 25 6 0 15 Sc 1 X i T A A NOTE ALL DIMENSIONS IN MILLIMETERS Table 30 TOBY L2 series modules tape UBX 13004573 RO7 Advance Information Product handling amp soldering Page 37 of 46 A b OX TOBY L2 series Data Sheet 7 2 Moisture Sensitivity Levels TOBY L2 series modules are Moisture Sensitive Devices MSD in accordance to the IPC JEDEC specification The Moisture Sensitivity Level MSL relates to the packaging and handling precautions required TOBY L2 series modules are rated at MSL level 4 For more information regarding moisture sensitivity levels labeling storage and drying see the u blox Package Information Guide 9 L For MSL standard see IPC JEDEC J STD 020 can be downloaded from www jedec org A A A 7 3 Reflow soldering Reflow profiles are to be selected according to u blox recommendations see TOBY L2 MPCI L2 series System Integration Manual 2 Failure to observe these recommendations can result in severe damage to the device 7 4 ESD precautions TOBY L2 series modules contain highly se
62. tion from CellLocate depending on which method provides the best and fastest solution according to the user configuration Hybrid positioning is available via a set of AT commanas that allow the configuration and the position request Full access to u blox short range communication Wi Fi modules is available through a dedicated SDIO interface This means that from any host processor a single serial port can control the cellular module and the short range communication module Allthe management software for the Wi Fi module operations runs inside the cellular module in addition to those required for cellular only operation Wi Fi driver Web User Interface WebUl Connection Config Manager For more details see the Wi Fi Cellular Integration Application Note 8 Firmware module update over AT command interfaces UART USB The feature can be enabled and configured through the UFWUPD AT command Firmware module update over the LTE 3G 2G air interface The feature can be enabled and configured through the UFWINSTALL AT command Improved cellular link quality and reliability on all operating bands Not supported by 50 product versions Not supported by 00 01 and 50 product versions Not supported by 00 and 50 product versions Not supported by 00 and 01 product versions UBX 13004573 RO7 Advance Information Functional description Page 9 of 46 biox Feature Smart T
63. tion is performed only once at module start up After the detection the module works at the fixed baud rate the detected one and the baud rate can only be changed via AT command see u blox AT Commands Manual 1 IPR L The automatic baud rate recognition autobauding is not supported by 50 module product version Frame format can be 8N2 8 data bits no parity 2 stop bits 8N1 8 data bits no parity 1 stop bit default frame configuration 8E1 8 data bits even parity 1 stop bit 801 8 data bits odd parity 1 stop bit 7N2 7 data bits no parity 2 stop bits 7N1 7 data bits no parity 1 stop bit 7E1 7 data bits even parity 1 stop bit 701 7 data bits odd parity 1 stop bit oOo 00 0 0 0 0 L Automatic frame format recognition is not supported by 00 01 and 50 module product versions UART serial interface can be conveniently configured through AT commands For more details see the u blox AT Commands Manual 1 IPR ICF IFC amp K AQ UPSV AT command and TOBY L2 MPCI L2 series System Integration Manual 2 2 5 1 1 Multiplexer protocol L The GNSS tunneling and the SIM Access Profile SAP multiplexer virtual channels are not supported by 00 01 and 50 modules product version TOBY L2 series modules include multiplexer functionality as per 3GPP TS 27 010 12 on the UART physical link This is a data link protocol which uses HDLC like framing an
64. udio 125 Filters LNAs Filters E LEE gt gt fh t Host Select VCC Supply ee H l Power On alt BCEE RTC Power Management Unit gt External Reset i 5 V_INT VO mmer Figure 1 TOBY L2 series block diagram L The TOBY L200 00S and TOBY L210 00S modules do not support the following interfaces which should be left unconnected and should not be driven by external devices o VBUS USB detect VUSB_DET UART interface SDIO interface DCC FC interface S digital audio interface Antenna detection ANT_DET Host Select functions General Purpose Inputs Outputs GPIO L The TOBY L201 01S and TOBY L280 00S modules do not support the following interfaces which should be left unconnected and should not be driven by external devices o VBUS USB detect VUSB_DET SDIO interface DCC FC interface S digital audio interface Antenna detection ANT_DET Host Select functions General Purpose Inputs Outputs GPIO DD 0 0 0 6 O DD UBX 13004573 RO7 Advance Information Functional description Page 6 of 46 biox TOBY L2 series Data Sheet LS The TOBY L200 50S and TOBY L210 50S modules i e the 50 product versions do not support the following interfaces which should be left unconnected and should not be driven by external devices o VBUS USB detect VUSB_DET 00000 1 4 Product description DCC FC interface PS digital audio interface Antenna detection
65. uplicators boosters etc except for the primary antenna ANT1 pin which maximum RF output power and corresponding maximum voltage into a 50 Q system is illustrated in Table 26 UBX 13004573 RO7 Advance Information Electrical specifications Page 33 of 46 b OX TOBY L2 series Data Sheet 5 Mechanical specifications Bin K Mi Mi 2 Mi Mi M3 P Indicator P3 Pi UN 5 na H L ye _ La y 1 aril C ANT2 pin H2 DRE IE B G GO EA LILY LT i Un THI Lil si EA H2 ANT1 pin HI 2 2 o T HI i t 0 ol H1 LULU LI D G H F A c Figure 3 TOBY L2 series dimensions Bottom an
66. vice that integrates a TOBY L2 series module and the compliance of the application device with all the applicable certification schemes directives and standards required for use in potentially explosive atmospheres are the sole responsibility of the application device manufacturer Table 25 describes the maximum total internal capacitance and the maximum total internal inductance considering internal parts tolerance provided by TOBY L2 series modules Module Parameter Description Value Unit TOBY L200 Ci Maximum total internal capacitance 267 UF TOBY L201 Li Maximum total internal inductance 12 8 pH TOBY L210 Ci Maximum total internal capacitance 267 UF TOBY L280 Li Maximum total internal inductance 12 9 pH Table 25 TOBY L2 series maximum total internal capacitance and maximum total internal inductance Table 26 describes the maximum RF output power transmitted by TOBY L2 series modules from the primary antenna ANT1 pin as Power Class 4 Mobile Stations for GSM 850 E GSM 900 bands and the corresponding maximum voltage into a 50 Q system load Module Parameter Description Value Unit All ANT1 Pout Maximum RF output power from ANT1 pin 35 0 dBm ANT1 Vout on 50 Q Maximum voltage from ANT1 pin into a 50 Q system load 12 6 Vrms Table 26 TOBY L2 series maximum RF output power and corresponding maximum voltage into a 50 Q load L The TOBY L2 series modules do not contain internal blocks which increase the input voltage e g like step up d
67. wer on input Input DC voltage at PWR_ON pin 0 3 6 0 Vv Rho_ANT Antenna ruggedness Output RF load mismatch ruggedness at ANT pins 10 1 VSWR Tstg Storage Temperature 40 85 RS Table 6 Absolute maximum ratings A The product is not protected against overvoltage or reversed voltages If necessary voltage spikes exceeding the power supply voltage specification given in table above must be limited to values within the specified boundaries by using appropriate protection devices 4 1 1 Maximum ESD Parameter Min Typical Max Unit Remarks ESD sensitivity for all pins 1000 V Human Body Model according to JESD22 A114 except ANT1 ANT2 pins ESD sensitivity for ANT1 ANT2 pins 1000 V Human Body Model according to JESD22 A114 ESD immunity for ANT1 ANT2 pins 4000 V Contact Discharge according to IEC 61000 4 2 8000 Vv Air Discharge according to IEC 61000 4 2 Table 7 Maximum ESD ratings A u blox cellular modules are Electrostatic Sensitive Devices and require special precautions when handling See section 7 4 for ESD handling instructions UBX 13004573 RO7 Advance Information Electrical specifications Page 23 of 46 biox 4 2 Operating conditions TOBY L2 series Data Sheet L Unless otherwise indicated all operating condition specifications are at an ambient temperature of 25 C Operation beyond the operating conditions is not recommended and extended exposure beyond them may affect device reliability 4 2 1 Operating tem
68. x AG Phone 41 44 722 74 44 E mail info u blox com Support support u blox com Advance Information TOBY L2 series Data Sheet Asia Australia Pacific u blox Singapore Pte Ltd Phone 65 6734 3811 E mail info_ap u blox com Support support_ap u blox com Regional Office Australia Phone 61 2 8448 2016 E mail info_anz u blox com Support support_ap u blox com Regional Office China Beijing Phone 86 10 68 133 545 E mail info_cn u blox com Support support_cn u blox com Regional Office China Shenzhen Phone 86 755 8627 1083 E mail info_cn u blox com Support support_cn u blox com Regional Office India Phone 91 959 1302 450 E mail info_in u blox com Support support_in u blox com Regional Office Japan Phone 81 3 5775 3850 E mail info_jp u blox com Support support_jp u blox com Regional Office Korea Phone 82 2 542 0861 E mail info_kr u blox com Support support_kr u blox com Regional Office Taiwan Phone 886 2 2657 1090 E mail info_tw u blox com Support support_tw u blox com Contact Page 46 of 46
Download Pdf Manuals
Related Search
Related Contents
Hydrometric Data Feed User Manual 取扱説明書 (3.14 MB/PDF) Operating Instructions PT-FX400E ICD-B300 全溶連 保安文書等申込書 - 全国高圧ガス溶材組合連合会 Mark Entry User Manual ACT-IR210 Manual - ACTiSYS Corporation network mediaplayer-450 wlan : pour des loisirs Manual del Usuario para Microsoft Portable Power (DC-21) Copyright © All rights reserved.