Home
        CM17202 PC/104-Plus Fast Ethernet Controller utilityModule
         Contents
1.     17202  PC 104 Plus Fast Ethernet  Controller utility Module      User s Manual               RTD Embedded Technologies  Inc      Real Time Devices   Accessing the Analog World   amp     BDM 610020025    1509001 and AS9100 Certified    CM17202  PC 104 Plus Fast Ethernet Controller  utilityModule     User   s Manual    RTD Embedded Technologies  INC   103 Innovation Blvd   State College  PA 16803 0906    Phone   1 814 234 8087  FAX   1 814 234 5218    E mail  sales  rtd com  techsupport  rtd com    web site  http   www rtd com    Revision History    04 08 2002 Version 1 0 Initial Release  Rev  A New Manual Naming Method    Published by     RTD Embedded Technologies  Inc   103 Innovation Blvd   State College  PA 16803 0906    Copyright 1999  2002  2003 by RTD Embedded Technologies  Inc        rights reserved  Printed in U S A     The RTD Logo is a registered trademark of RTD Embedded Technologies  cpuModule and utilityModule are  trademarks of RTD Embedded Technologies  PhoenixPICO and PheonixPICO BIOS are trademarks of Phoenix  Technologies Ltd  PS 2  PC XT  PC AT and IBM are trademarks of International Business Machines Inc  MS   DOS  Windows  Windows 95  Windows 98 and Windows NT are trademarks of Microsoft Corp  PC 104 is a  registered trademark of PC 104 Consortium  All other trademarks appearing in this document are the property of  their respective owners     Table of Contents    CHAPTER 1    INTRODUCTION Lascccutenti testes tesu estos eto itt retos Ree eR  1  ELECTRI
2.   Saeed OE ere iN ues 15   CHAPTER 4 RETURN POLICY AND WARRANTY wiccccssssssssssssssssssssssssssscsssssssssssssssssssssssssssssssssessseses 16  RETURN aO  E Sa eterne    BR a de be 16    LIMITED  WARRANTY                                                                      17    Table of Figures    FIGURE 4  COMPONENTEOCATIONS     eet eee i eee ee         ye ce E        eo ee o eee ed ue ee T eA Ob uet ee ue uec  3  FIGURE 2    RJ 45 JACK  CONNECTOR                                                10  FIGURE 3  PCI SELECTOR ROTARY SWITCH          13  Table of Tables   TABLE 1  LIST OF CONNECTORS AND SWITCHES  e a a E Ea a aa E aaa EOS is EE EEE iOS eiS 4  TABLE Z PC 104 XT BUS CONNECTOR         r rure er eet eiu sert eter e nre e eee PE Edge 5  TABLE3  PCAO4  AT BUS CONNECTOR      aia ede eere bie o UIN Deere Renin el aeree tesis e    6  TABLE 4  PC 104 PLUS BUS SIGNAL   55              5        1     7  TABLE 5  RJ45 SIGNAL   55                            10  TABLE 6  CN5 SIGNAL ASSIGNMENTS                                               sese                                  esee sees ases esses aseo 11  TABLE 7       INTERFACE CONNECTOR                    12             8 LED INDICATORS 33 ee neret eMe 13    TABLE 9  CONNECTOR JUMPER 5          5 8      15    Chapter 1 INTRODUCTION    e This manual gives information on the CM17202 PC 104 Plus Fast Ethernet Controller  utilityModule M     This module provides a twisted pair 100 Mbit ethernet connection to support the Real Time  
3.  is supported by DOS  Windows 3 1  Windows 95  Windows NT  Windows 2000   VxWorks and QNX  For DOS and Windows 3 1  drivers can be downloaded from the Intel Developer web  site at the 21143 Drivers page  For Windows 95  Windows 98  Windows NT  and Windows 2000  the  drivers are supplied by Microsoft along with the operating system  The latest drivers for all of the above  mentioned operating systems can also be found at the Intel Developer web site at the 21143 Drivers page   For VxWorks and QNX please contact them directly     CM17202 Fast Ethernet Controller utilityModule    2 RTD Embedded Technologies  Inc     Chapter2 CM17202 LAYOUT    Finding Pin 1 of Connectors    The three possible ways to determine pin 1 on the connectors are   l  Asquare white area silk screened on the PC board  2  Asquare solder pad visible on the bottom of the PC board  3  Anumeral 1 silk screened near pin 1 on the top of the PC board    Component Locations    The figure below shows switch and jumper locations           CN3  PCI Connector          CN6  MII Interface  LEDs  10 100 Mbit s Connector  Receive  Transmit  Link  Activity  Collision    U6  PLCC Socket    5  5  5   8      2         E  5         8               Jumpers    CN5  10 Pin Twisted Pair    CN4  RJ45 Connector     gt  Connector  Optional                   XT Bus       RSWI  PCI Rotary Switch CN2  AT Bus    Figure 1  Component Locations    CM17202 Fast Ethernet Controller utilityModule    3 RTD Embedded Technologies  Inc     List of 
4. 04 Plus or PCI 104 stack  To do this  you will connect the PCI and or ISA  bus connectors on the CM17202 to the respective connectors of your stack     Before you can use this module you have to set the PCI board selector rotary switch located on the module   SW1   If this module is the first module from the CPU module select  0   if it is the second module select       etc              Figure 3  PCI Selector Rotary Switch    LED Indicators    The LEDs on the board are used to indicate various operations of the on board physical layer chip  These LEDs  do not indicate any operations that may be occurring on an add on physical layer board which is connected  through the      connector  Listed below are the LEDs starting with the one closest to the PC 104 connector      s jw                Table 8  LED Indicators    CM17202 Fast Ethernet Controller utilityModule    13 RTD Embedded Technologies  Inc     Chapter 3 INSTALLING THE UTILITYMODULE       WARNING   Like all equipment using CMOS devices  the CM17202 must be protected from static    discharge  Never touch any of the parts except at static free workstation  Use anti static  bag shipped with the CM17202 to handle the board    The following sections contain information on configuring the CM17202 PC 104 Plus Fast Ethernet Controller  utilityModule     Please read the entire section before attempting to use the utilityModule        Recommended procedure     We recommend you follow the procedure below to ensure the stacking of 
5. CAL SPECIFICATIONS    eec eet                                     ie t cred tcv ete deed dritter te te             1  MECHANICAL SPECIFICATIONS         ERR he RO    1  IMMO 110 INH V N Og 2  To na HnI                           n 2   CHAPTER 2 CM17202 LAYOUT                        RR eb edet ie 3  FINDING PIN  T OF CONNECTORS             tse eet      credet          cere rd eese crece ie        Nee Hee 3  COMPONENT  LOCATIONS                            3  LIST OECONNECTORS AND SWITCHES            eeu eee          4  PC 104 Bus CONNECTORS         AND CN2                         eee thnnne seen              5  PC 104 PrUS PCI CONNECGTOR                                    eese eer          7   PC IO4 Plus PCI Bus Signals    ee eee eere dee ee RR Pe yes                       E e        8  RJ45 TWISTED PAIR ETHERNET                              10  TWISTED PAIR ETHERNET      5         0002   2   2 0 0000000000000000000000000000000000000                        E 11  MIT CONNECTOR  GNO    e                          od ee bete etes dece dba 12  PCI BOARD SELECTOR ROTARY SWITCH  51              13  ELED INDICATORS                                                                                                                                          13   CHAPTER 3 INSTALLING THE UTILITYMODULE    0    ccsccessssscsssssssssssssssssssssssessssssssssssssssssssssseses 14  RECOMMENDED PROCEDURE      5                                                      14  JUMPER SETTINGS ie                 
6. CULAR PURPOSE  ARE LIMITED TO THE  DURATION OF THIS WARRANTY  IN THE EVENT THE PRODUCT IS NOT FREE FROM  DEFECTS AS WARRANTED ABOVE  THE PURCHASER S SOLE REMEDY SHALL BE REPAIR OR  REPLACEMENT AS PROVIDED ABOVE  UNDER NO CIRCUMSTANCES WILL RTD Embedded  Technologies BE LIABLE TO THE PURCHASER OR ANY USER FOR ANY DAMAGES   INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES  EXPENSES  LOST PROFITS   LOST SAVINGS  OR OTHER DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE  PRODUCT     SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR  CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS  AND SOME STATES DO NOT  ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS  SO THE ABOVE  LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU     THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS  AND YOU MAY ALSO HAVE OTHER  RIGHTS WHICH VARY FROM STATE TO STATE     CM17202 Fast Ethernet Controller utilityModule    17 RTD Embedded Technologies  Inc     RTD Embedded Technologies  Inc   103 Innovation Blvd   State College PA 16803 0906  USA    Our website  www rtd com    CM17202 Fast Ethernet Controller utilityModule   18 RTD Embedded Technologies  Inc     
7. Connector CN3 carries the signals of the PC 104 Plus PCI bus  These signals match definitions of the PCI Local  Bus specification Revision 2 1  The following tables list the pinouts of the PC 104 Plus bus connector     a     I           _p_    L   L  GNDSOVKEY    Reseved   8          _                                       3   aws     p   aoa              4                   ob   ao       5                                   6   am   vwo   ao               3 3       5  0   PAR     PERR             ox   op                                            _    ADI C BE2              an            GND              GND            Ros   vwo      vwo     m       GND                                 ae                                   SJNIDE            a ae    Table 4  PC 104 Plus Bus Signal Assignments       Note  The KEY pins are to guarantee proper module installation  Pin A1 will be removed and the  female side plugged for 5 0V I O signals and Pin D30 will be modified in the same manner for  3 3V I O  It is recommended that both KEY pins  A1 and D30  be electrically connected to  GND for shielding     CM17202 Fast Ethernet Controller utilityModule    7 RTD Embedded Technologies  Inc     PC 104 Plus PCI Bus Signals  The following table contains brief descriptions of the PC 104 Plus PCI bus signals     Address and Data  AD 31 00     Address and Data are multiplexed  A bus transaction consists of an address cycle followed by one  or more data cycles   C BE 3 0      Bus Command Byte Enable
8. Connectors and Switches                                     Connector Function Dimension  CNI  CN2 XT AT Bus Connector 64   32 pins  CN3 PCI Bus Connector 120 pins  CN4 Twisted Pair Ethernet Connector RJ45  CN5 Twisted Pair Ethernet Connector 10 pins  CN6 MII Interface Connector 40 pins  SWI  PCI Board Selector Rotary Switch Rotary Switch       Table 1  List of Connectors and Switches    CM17202 Fast Ethernet Controller utilityModule    4 RTD Embedded Technologies  Inc     PC 104 Bus Connectors  CN1 and CN2    Connectors CN1 and CN2 provide PC 104 bus connections  CN1 carries XT bus signals  and CN2 carries  additional signals for the AT bus      m                                              3       meme                               QN       Table 2  PC 104 XT Bus Connector    CM17202 Fast Ethernet Controller utilityModule   5 RTD Embedded Technologies  Inc          104      Bus Connector  CN2           me   mene     3  us   xe      3 f ws   me _   owe  mes           m   3  oue   beue         s    ww          Table 3  PC 104 AT Bus Connector       Note  Two locations on the bus have mechanical keying pins to help prevent misconnection of the  PC 104 bus  These keying pins are a part of the PC 104 standard  and we strongly recommend  you leave them in place     If you have other modules without keying pins  we suggest you modify them to include  keying     CM17202 Fast Ethernet Controller utilityModule   6 RTD Embedded Technologies  Inc     PC 104 Plus PCI connector  CN3    
9. Devices    PC 104 Plus cpuModules    and other PC 104 Plus processor modules     Features  The following are major features of      CM17202 utilityModule      Intel 21143 TD PCI Fast Ethernet Controller and ICS1892Y 10 100BaseTX integrated  physical transceiver     MII Interface    Electrical Specifications    e Compatible with PCI Specification  e Compatible with PC 104 Plus Specification    Mechanical Specifications    e Compatible with PC 104 Plus Specification when using the 10 pin twisted pair connector   CN5  This connector is not the default factory installed connector  The factory default  connector is the RJ45 connector  CN4  Please note that all RJ45 connectors  default  configuration   violate the height limit of all PC 104 Specifications  If height limit is required   the RJ45 connector cannot be installed  and the optional 10 pin connector must be installed by  the factory    e Dimensions  3 8 x 3 9x 0 6   97 x 100 x 16 mm    e Weight  mass   3 0 ounces  85 grams     CM17202 Fast Ethernet Controller utilityModule    1 RTD Embedded Technologies  Inc     Environmental    e Operating Temperature   40   to 85   C  e Storage Temperature   40   to  85   C     Non Condensing Relative Humidity   lt  95  at 40  C    WARNING  Like all equipment using CMOS devices  the CM17202 must be protected from static  discharge  Never touch any of the parts except at static free workstation  Use anti   static bag shipped with the CM17202 to handle the board    Software    The 21143 TD
10. c registers to a known state     CM17202 Fast Ethernet Controller utilityModule    8 RTD Embedded Technologies  Inc     Interrupts  INTA     Interrupt A is used to request Interrupts     INTB     Interrupt B is used to request Interrupts only for multi function devices   INTC     Interrupt C is used to request Interrupts only for multi function devices   INTD     Interrupt D is used to request Interrupts only for multi function devices     Power Supplies and VIO   5V     5 volt supply     12V     12 volt supply    12V     12 volt supply    3 3V     3 3 volt supply   VIO    This signal typically is the I O power to the bus drivers on a PCI bus card     CM17202 Fast Ethernet Controller utility Module    9 RTD Embedded Technologies  Inc     RJ45 Twisted Pair Ethernet      4    Connector CN4 is for UTP  Unshielded Twisted Pair  wiring normally used for 10 100Base T Ethernet  It is the  default factory installed twisted pair connector on the board     The following table gives the pinout of CN4       Pin   Signal   Function    in out          _   NC   Reserved        5   NC   Notcomeced                 RX    Receive    imn     27   NC   Notconnected          5   NC   Notcomeced           Table 5  RJ45 Signal Assignments    The figure below shows the pin numbering of CN4 when looking into the connector     12345678    Figure 2  RJ 45 Jack Connector    CN4 is a standard female RJ 45 connector     Note         RJ45 connector exceeds the height limit of the PC 104 specifications  The 
11. fects in materials and workmanship for one year following the date of shipment  from RTD Embedded Technologies  INC  This warranty is limited to the original purchaser of product and  is not transferable     During the one year warranty period  RTD Embedded Technologies will repair or replace  at its option  any  defective products or parts at no additional charge  provided that the product is returned  shipping prepaid   to RTD Embedded Technologies  All replaced parts and products become the property of RTD Embedded  Technologies  Before returning any product for repair  customers are required to contact the factory for an  RMA number     THIS LIMITED WARRANTY DOES NOT EXTEND TO ANY PRODUCTS WHICH HAVE BEEN  DAMAGED AS A RESULT OF ACCIDENT  MISUSE  ABUSE  such as  use of incorrect input voltages   improper or insufficient ventilation  failure to follow the operating instructions that are provided by RTD  Embedded Technologies   acts of God  or other contingencies beyond the control of RTD Embedded  Technologies   OR AS A RESULT OF SERVICE OR MODIFICATION BY ANYONE OTHER THAN  RTD Embedded Technologies  EXCEPT AS EXPRESSLY SET FORTH ABOVE  NO OTHER  WARRANTIES ARE EXPRESSED OR IMPLIED  INCLUDING  BUT NOT LIMITED TO  ANY  IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR  PURPOSE  AND RTD Embedded Technologies EXPRESSLY DISCLAIMS ALL WARRANTIES NOT  STATED HEREIN  ALL IMPLIED WARRANTIES  INCLUDING IMPLIED WARRANTIES FOR  MECHANTABILITY AND FITNESS FOR A PARTI
12. optional CN5  connector is also a 10 100Base TX connection and can be factory installed if the RJ45  connector height is a problem    CM17202 Fast Ethernet Controller utilityModule    10 RTD Embedded Technologies  Inc     Twisted Pair Ethernet      5    This is an optional connector which can be factory installed in place of the RJ45 connector  This connector is not  installed when the RJ45 connector  CN4  is installed             Signal   _ Function      ivout   in  TX  out     NC   Notcomeced f       i    NC   Notcomeced        NC   Reserved       NC   Notcomeced        NC   Notcomeced      Not connected         Table 6  CN5 Signal Assignments             CM17202 Fast Ethernet Controller utilityModule    11 RTD Embedded Technologies  Inc     MII Connector  CN6    28  29  30  31  32  33    34  35  36  37  38  39     2       mm              Management Data Input Output     Management Data Input Output   Input Output   o            memo       o                     os  epo pem          7 17          o0  eom pee  ce       s  epo m              o  eom  ee            ow          emm       mm  d          ow fe fm    meam        ow  e  m                 9 elm el           Table 7  MII Interface Connector Layout       CM17202 Fast Ethernet Controller utilityModule    12 RTD Embedded Technologies  Inc     PCI Board Selector Rotary Switch  SW1    Since the utilityModule    uses stack through buses  the only hardware installation you will need to do is to  place the module onto the PC 1
13. s are multiplexed  During the address cycle  the command is defined   During the Data cycle  they define the byte enables   PAR    Parity is even on AD 31 00  and C BE 3 0   and is required     Interface Control Pins  FRAME     Frame is driven by the current master to indicate the start of a transaction and will remain active  until the final data cycle   TRDY     Target Ready indicates the selected devices ability to complete the current data cycle of the  transaction  Both IRDY  and TRDY   must be asserted to terminate a data cycle   IRDY     Initiator Ready indicates the master s ability to complete the current data cycle of the transaction   STOP     Stop indicates the current selected device is requesting the master to stop the current transaction   DEVSEL     Device Select is driven by the target device when its address is decoded   IDSEL    Initialization Device Select is used as a chip select during configuration   LOCK     Lock indicates an operation that may require multiple transactions to complete     Error Reporting                 Parity Error is for reporting data parity errors     SERR     System Error is for reporting address parity errors     Arbitration  Bus Masters Only     REQ     Request indicates to the arbitrator that this device desires use of the bus   GNT     Grant indicates to the requesting device that access has been granted     System  CLK    Clock provides timing for all transactions on the PCI bus     RST     Reset is used to bring PCI specifi
14. the modules does not damage  connectors or electronics    0 Turn off power to the PC 104 Plus system or stack    1 Select and install standoffs to properly position the utilityModule    on the PC 104 Plus stack   Touch a grounded metal part of the stack to discharge any buildup of static electricity   Remove the utilityModule    from its anti static bag     Check to see if the keying pins in the PCI bus connector are properly positioned        A    N    Check the stacking order and set the PCI Board Selector Rotary Switch  RSW1  see Section  2 13     6 Hold the utilityModule    by its edges and orient it so that the bus connector pins line up with  the matching connector pins on the stack     7 Gently and evenly press the utilityModule    onto the PC 104 Plus stack     CAUTION  Do not force the module onto the stack  Wiggling the module or applying too much force  may damage it  If the module does not readily press into place  remove it  check for bent  pins or out of place keying pins  and try again     CM17202 Fast Ethernet Controller utilityModule   14 RTD Embedded Technologies  Inc     Jumper Settings    You cannot use both the RJ45 connector and the MII connector at the same time  Table 10 lists the Jumper  settings to select each of the connectors          Selected  JP2    Table 9  Connector Jumper Settings       Note   Inorder to use the MII Connector for an external transceiver  the user must set Jumpers JP1   JP3  and     4 to the 2 3 position and JP2 to the 1 2 posi
15. tion  Likewise  the user must set  Jumpers JP1  JP2  JP3  and JP4 to the 1 2 position to use the RJ45 Connector     CM17202 Fast Ethernet Controller utilityModule   15 RTD Embedded Technologies  Inc     Chapter 4 RETURN PoLICY AND WARRANTY    Return Policy  If you wish to return a product to the factory for service  please follow this procedure   Read the Limited Warranty to familiarize yourself with our warranty policy   Contact the factory for a Return Merchandise Authorization  RMA  number     Please have the following available        Complete board name    Board serial number    A detailed description of the board s behavior    List the name of a contact person  familiar with technical details of the problem or situation  along  with their phone and fax numbers  address  and e mail address  if available      List your shipping address      Indicate the shipping method you would like used to return the product to you     We will not ship by next day service without your pre approval   Carefully package the product  using proper anti static packaging   Write the RMA number in large  1   letters on the outside of the package   Return the package to     RTD Embedded Technologies  Inc     103 Innovation Blvd   State College PA 16803 0906    USA    CM17202 Fast Ethernet Controller utilityModule    16 RTD Embedded Technologies  Inc     Limited Warranty    RTD Embedded Technologies  Inc  warrants the hardware and software products it manufactures and  produces to be free from de
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Xilinx UG363 Virtex-6 FPGA Memory Resources User Guide    RST-BA_Fork_D-GB  RTV86073 Span 13Sept  Nº MODELO WV-SFR531/WV-SFN531 - psn  CogniBlox Hardware Manual  user manual - Bioinformatics  ALU SPOT  Soleus Air MAC 7500 User's Manual  WID380 300 Mbps Wireless Enhanced USB Adapter User Manual    Copyright © All rights reserved. 