1. DATA TRANSPORT Below in standard list project menu of SKWorkshop there is Data Transport function it is an important function because it allows to send variables from one Instrument to another one or from one Instrument to Touch Panel and or viceversa It is enough to fill the Address field with Source and Destination address and to define the event that produce the updating of the data exchanged this event can be a trigger variable to 1 defined by address or a time in this case it is necessary to set the time interval in step of seconds 1s minimum in case of more transfer with the same time only the last one will be executed p r e Invensys Eliwell Controls s r l Via dell Industria 15 Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 8 www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 Then this function can be used to transfer data coming from an external Source to internal memory as Destination it allows to define and to adjust data addressed only in the Data Trans port table without the need to update all single menu Very useful a combination of Data Transfer function and macro the best use of communication line between Instrument and Touch Panel consist to exchange variables regarding the only page displayed to have speed updating of value
2. In the main menu select File F then New Pro N In the window define the Project Properties i e Project Name Path type of screen and Model a New Project Project Properties Project Name Path Model SK 070A5 Show Model Horizontal Model Parameters Model Size 7inch Resolution 800x480 Pixels VGA Color 262 144 Colors TFT LCD User Memor 12M Power Supp DC24V 15 COM1 RS232 RS422 RS485 COM2 RS232 RS422 RS485 USB 2 Ports B type A Type Ethernet RJ45 A second window will follow to define the serial communication channel and mode See example the connecting channel COM1 uses Modbus protocol i e Modbus RTU special It means Master special defines that only command 10 is used instead of commands 10 and 6 to write registers Please note also the PLC Continuous Address in the example is set to 16 These are the num ber of continuous registers readable or writeable the number is depending from the electronic control used as Slave P New Link Link ID 1 Link Name Linki Connecting I COM1 Device Servic Modbus vl Modbus RTU Special PLC Continuous Addres 16 vl Invensys Eliwell Controls s r l Via dell Industria 15 Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 3 www eliwell com eei Touch Graphical Interface Application Notes r
3. To obtain this behaviour in Data Transfer setting set as Source the address variable and num ber of words single variable or group of variables with successive addresses of Instrument and internal storage LWxx as Destination then set as trigger for this Data Transfer an internal storage variable LBxx and Automatic Reset PUTES SP Data Transfer ejr f Data Iransfer Attribute Attribute Timed Interval 1 O Ti Triggered Triggered Trigger Bits LB1 Address Type Bit v Automatic Reset Number of Word 1 E Address Type Word iv a Source Addres LBO Number of Word 5 Ge Destination AdLBO La Source Addres 4x8335 Destination AdLW 1 After that build a macro that set to 1 the over defined LBxx see Macro paragraph for details now in the menu where those variables shall be used insert the Timer function it is an object in the object menu specifying the macro to be launch and its interval p r e Invensys Eliwell Controls s r l Via dell Industria 15 Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page Q www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 In the next picture the object Timer call every 100ms the macro Marco0 ee General ID T0001 Properties Run Condition Always Perform vl Q Frequenc
4. Pr Invensys Eliwell Controls s r l Via dell Industria 15 Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 1 6 www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 USE CASE FREE SMART FILE FREE SMART zip What SUPERVISOR R W RAM EEPROM locations probes status alarms Set basic commands ON OFF Alarm Logging ModBus RTU Communication Display number with with without decimal point Display Alarms List and Alarm Logging Enumerators Object Function used TEXT e e Static Picture e Bit Lamp e Screen Button e Numeric Display e Numeric Entry e Alarm Control Other e Alarm Log MODBUS MAST ER T tre TGIO43AE S Connection FIELD RS485 RS485 in ModBus RTU Controller example NETWORK Ethernet SK 043AS Touch Screen FREE Smart SUPERVISOR RS485 Ethernet p r Ir vETIS me Eliwell Controls s r l Via dell Industria 15 e Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 17 www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 USE CASE FREE SMART EWCM EO FILE EWCM EO zip 1 FREE SMART and SK 043AS Touch Screen What NETWO
5. 0 1 e g tri er p r e invens s Eliwell Controls s r l Via dell Industria 15 Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 GENERAL DESCRIPTION Target of this document is to give the basic information to develop a Touch Screen project as interface with an Eliwell Controls device SKWorkshop V4 0 tool is the instrument to develop the project Run the CD on your computer and follow the specific instruction to install For more information please refer to following documents Available Literature Data Sheet CT123179 80 81 Overview Instruction Sheet 91924278 Installation instructions User Manual 9MA10234 Full SKWorkshop description TGI MODELS 3 5 4 3 7 MEL TGIO35AE TGIO43AS B TGIO7AS TGI0350100400 TGI0430110400 TGI0700210400 TET LCD display Dimensions o o a USB DRIVERS See APPENDIX p r e Invensys Eliwell Controls s r l Via dell Industria 15 Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 2 www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 INITIAL SETTINGS
6. Ethernet Invensys Eliwell Controls s r l Via dell Industria 15 Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 20 www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 USE CASE FREE EVOLUTION FILE FREE EVOLUTION zip 2 FREE EVOLUTION on SK 070AS Touch Screen What NETWORK Share variables probes status alarms Set basic commands ON OFF What SUPERVISOR Share variables probes status alarms Set basic commands ON OFF Variables numeric and strings Bridge Variables Logging MODBUS MASTER DUIIIIIIIIIIIIIIIII ETHERNET MODBUS TCP IP 3rd PARTY MODBUS TGIO70AS ou BINDING o FREE Studio WEB ACCESS ae id x a LA simultaneously Connection RS485 in ModBus RTU ETHERNET Controller example FREE Evolution EVS Plugin FIELD RS485 NETWORK Ethernet SUPERVISOR RS485 Ethernet e Invensys Eliwell Controls s r l Via dell Industria 15 Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 21 www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 APPENDIX TIPS FREE Family Modbus Address Fo
7. S Connection FIELD RS485 RS485 in ModBus RTU Controller example NETWORK Ethernet FREE Smart EWCM EO SUPERVISOR RS485 Ethernet p r e Invensys Eliwell Controls s r l Via dell Industria 15 e Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 1 Q www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 USE CASE FREE EVOLUTION FILE FREE EVOLUTION zip 1 FREE EVOLUTION AHUOS3 on SK 070AS Touch Screen What NETWORK Share variables probes status alarms Set basic commands ON OFF What SUPERVISOR Share variables probes status alarms Set basic commands ON OFF R W Controller Parameter and Variables numeric and strings Bridge Variables Logging Object Function used e TEXT e Timer e Static Picture e Historical Trend e Bit Lamp e Alarm Control e GIF display Other e Screen Button also with Macro e Alarm Log e Functional Button e Setting of Language by functional button e Numeric Display e On Off Buzzer on the Touch by functional button e Numeric Entry also with Macro e Data Transport e Ascii Character Entry with Macro e Macro MODBUS MASTER RS485 MODBUS SLAVE TGIO70AS Connection RS485 in ModBus RTU Controller example FREE Evolution FIELD RS485 NETWORK Ethernet SUPERVISOR RS485
8. display B Historica E Keyboard Components E P Alarm Log We 000 Analog Alar amp Recipe E Recipe 1 v X Marco REED OK L 23818 4s ni Eh S nk Compiles successfully Top m Size Width p Height L E m start fam 9 Esplora risorse gm SKWorkshop C I2 QuickStartTouchs bandieraUSA bmp M Adobe Reader File Flag of the U CLOCK SETTING Important thing to do is to set if shown the clock of HMI Each HMI has 5 Dial switch normally these dial switches are OFF set dip1 amp dip3 to ON at the next power on it will be possible to set the clock and other parameters Once time has been set set again the dip in OFF state and turn off on the HMI SIMULATION Before to simulate the project itis necessary to compile the project by clicking on Knocker Image By clicking on EE afterwards it is possible to debug the application The communication channel will be required set the COM address of own PC this COM has to be connected to external device with opportune tool p r e Invensys Eliwell Controls s r l Via dell Industria 15 e Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 14 www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 DOWNLOAD TO HMI Before to download the project to HMI i
9. next power on it will be possible to set a fixed IP address and other parameters Once you have set turn the dip in OFF state again and turn off on the HMI Master setting example Communication Port Properties alps 4 Communication Port Properties General Parameter General Parameter IP address set Other Link ID 3 ie IP Address 192 168 1 a 111 HMI Address 0 Link Name i gt Port number 502 PLC Address 4 Connecting Int Ethernet iv Communication T 20 HMI Site Local iv Setting IP 192 168 1 110Port number 8000 iq ie ie Overtime time 1 1000 Connection Ser Modbus v Modbus Master TCP IP DIU ie Retry Times 3 Ea Address Model Standard Mc v PLC Continuous addres 16 Spare set parameters Spare paramet 0 Spare paramet 0 Spare paramet 0 Spare paramet 0 Lx IMPORTANT NOTE IP address here above is the Slave IP address where Master sends the message p r e Invensys Eliwell Controls s r l Via dell Industria 15 Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 5 www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 Slave setting example 4s Communication Port Properties f s Communication Port Properties General Parameter General Parameter IP addr
10. over the screen To open a window over the current screen use a screen button in the same way for a screen it is necessary to specify number of screen here called window to be opened RECIPE Useful to write or to load a set of values to or from a Device With RECIPE it is possible to define the type of data with reference address then send or to receive this recipe use Functional Button p r e Invensys Eliwell Controls s r l Via dell Industria 15 e Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 1 3 www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 FUNCTIONAL BUTTON Important action is reserved to functional button it allows to perform touch panel setting as selection language buzzer on touch on off and other several functions zx SKWorkshop C AsamKoonW reeEvolutionW reeEvolution shm SET PROBE More Button i Numentric Display On T lig Numerical Input Display BELLA DEN ii asc chorater ocv a8 ASCII Charater Entry Y BitLamp c Multistate Switch Multistate Lamp 8 Message Display Time Date E oes amp Static Picture PLC Cor Picture Display GIF Display Bar Graph TEMPERATURA C UMIDITA RELATIVA rH 008 Window an 009 Window Recipe selector amp Historical Da J Recipe data
11. RK Share variables probes status alarms Set basic commands ON OFF What SUPERVISOR R W Controller Parameter and Variables numeric and strings Bridge Alarm Logging Object Function used TEXT Static Picture Bit Lamp Multistate Lamp Bit Button Screen Button Numeric Display Numeric Entry Alarm Control Other e Alarm Log ETHERNET MODBUS MODBUS MASTER TCP IP Ser EE ERER T I LA p TGIO43AE S Connection FIELD RS485 RS485 in ModBus RTU Controller example NETWORK Ethernet FREE Smart EWCM EO Invensys SUPERVISOR RS485 Ethernet A Eliwell Controls s r l Via dell Industria 15 Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 1 8 www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 USE CASE FREE SMART EWCM EO FILE EWCM EO zip 2 EWCM EO MK504 on SK 0070AS and SK 043AS Touch Screen What NETWORK Share variables probes status alarms Set basic commands ON OFF What SUPERVISOR Share variables probes status alarms Set basic commands ON OFF R W Controller Parameter and Variables numeric and strings Bridge Variables Logging MODBUS MASTER RS485 free TGIO43AE S ETHERNET MODBUS TCP IP MODBUS MASTER TGIO43AE
12. e Number of Sampling Read Address LW1 Ez Sampling Method 9 Time _Interval 1_ second s Triggerec Clocked menu AILI TEMPERATURE TREND Link h E PLC Cor 7 G Cock GIF Display Eliwell Controls s r l Via dell Industria 15 Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 1 2 www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 MACRO By action on sxx itis possible to write a Macro The Macro are subroutine writable in C language they can manage algorithm also complex they can be triggered by Timer Object at specified time interval or by an event i e button Here an example of macro used to set to 1 the variable trigger1 then used to trigger a Data Transport event Macro Editor a7 xXBD VG Number 0 Macro Name Marco include MacroInit h void Macro main IN p t MarcoInit ToDo triggeri i Specification of variables Variable Name DataClass Bytes B id Write Prope Address Type Address onnection Typ PLC Station 1 triggeri bool 1 read write LB Dd dick the right mouse button T 100 2 Debug Information Output WINDOW The definition of Window in the project menu is very close to Screen definition the only differ ences are the size and position
13. e of beep sound if a button is actived There is also if Load Screen to set the first screen during start up if not set a demo will appear In the Alarm Setting menu a beep sound can be set it will occur in case of Alarm see Alarm Log for details Other pages as Set User Password HMI connected to the printer Setting Storage Location are available to define password to limit the access to connect a printer and to save data in internal flash or connected memory standard key 4s HMI Parameter Setting HMI Parameter Setting Set User Password HMI connected to the printer Settings Storage locations lt gt Model Other HMI Model SK 043AS x Hide the mouse cursor Floating point Settings Display Type Horizontal mi Standard Appoint HMI Start Setting This set of some agreement effective only Splash creen Saver Time 1 Flicker Frequency 10 Touch Voice A voice tips C Screensavers Screen Touch invalid labeled C Use guest system labeled if Load Screen sceen2 v Show Time 1s iv Alarm setting Alarm Voice No sound reminders C Alarm occurs picture Flash Operation Mode e Touch Type Operat USBeMouse Action e Disabling the buzzer To disable the buzzer select no sound reminders option in the Touch voice combo box If the Buzzer has been disable the function bottom Touch Voice sound on off is disabled SCREEN DEFINITION AND OBJECT The defini
14. eei Touch Graphical Interface Application Notes code 91S24295 1 rel 30 07 13 Touch Graphical Interface Contents DEFINITIONS esesesesesesesesesessssssssssssssosos 1 FUNCTIONAL BUTTON ee eee eee 14 GENERAL DESCRIPTION 2 CLOCK SETTINGS oro riI EXE p FREE EPdR Idee 14 TGI MODELS 2 ericsiio sinc ee ose E as 3 SIMULATION iciose oe ee iN FE EEPR EYE Re HA Fra al 14 INITIAL SETTINGS e c eee eee 3 DOWNLOD TO HMI DIAL SWITCH 15 ETHERNET IP SETTINGS 5 DOWNLOADS cii re esse bya e Sup Re Rea eee Ye er YES sUs 16 HMI PARAMETERS SETTINGS 7 A SE CASES E cuternncsvseserccucereussseseesss 17 SCREEN DEFINITION AND OBJECTS 7 FREE SMART oit Qo PIRE TIVE 17 ALARM LOG oo E EIRRRESA RISE Ex X eE nidore 8 EWCM EO a ise tex OREXVR ER PETPERENS 18 DATA TRANSPORT eee ee eee eee eee ooe 8 FREE EVOLUTION e eee 20 HISTORICAL DATA sies esa E a O aa epa ao aF ee es 12 APPENDIX TIPS eseososesesessesesesessosose 22 MACRO WINDOW RECIPE 13 DEFINITIONS e DIAL SWITCH Other name for Dip Switch TOUCH VOICE Other name for Buzzer HMI Human Machine Interface Macro C language subroutine PLC Programmable Logic Controller i e FREE Smart or Evolution Modbus special Modbus com mands 10 and 6 only BB Bit Button Binary button
15. el 30 07 13 The next window will define the starting screen color and shape You may select also a picture as screen background FJ New Screen Screen Name Background Defaut 8G Calor FG Color l Pattern L Solid v tting Z HMI Parameter Setting SW_in_progress Adobe Reader 5 Rai TV La diretta LY Microsoft Word By clicking on Link 1 it is possible to set e Parameter for serial communication Baudrate HMI Address touch screen address PLC address it is the electronic control serial address or leave default values for other parameters Invensys Eliwell Controls s r l Via dell Industria 15 Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 4 www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 Please Note Only PLC Continuos Address has to be set considering the capability of electronic control regarding the maximum number of registers sending in the serial channel ETHERNET IP SETTING Alternative to 485 communication is in some cases the Ethernet line In such case as mandatory step set the IP address of HMI for first Each HMI has 5 dial switch typically dip switches are all OFF By setting dip1 amp dip3 to ON at the
16. ess set Other Link ID 1 IP Address 192 168 HMI Address E Link Name Linki Port number 502 PLC Address D Connecting Int Ethernet 7 Communication T 29 gt I i e I HMI Site Local v Setting IP 192 168 1 110Port number 8000 Overtime time 1 1000 Connection Ser Modbus x Modbus Slave TCP IP PEE vertime time Retry Times Address Model Standard Mv PLC Continuous addres 16 x Spare set parameters Spare paramet 0 Spare paramet 0 Spare paramet 0 Spare paramet 0 IMPORTANT NOTE P address here above is the IP address of slave itself the same address defined by dip switch or HMI Plaese Note HMI and PLC Master Slave addresses are swapped Master HMI address 0 Slave HMI address 1 Master PLC address 1 Slave PLC address O p r e Invensys Eliwell Controls s r l Via dell Industria 15 Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 6 www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 HMI PARAMETER SETTING To set or to change the setting of HMI by clicking over HMI Parameter Setting in the first page of this menu itis possible to define the type of the screen the starting screen the screen saver time and screen name the enabl
17. lay Select All A Ctrl A Time Date 7 sin LETTTTEEENEN Layer amp Picture Display Assemble amp GIF Display Paste P Ctrl V A Delete D Del Zoom gt Dynamic Diagram B Bar Graph Rex Meter Emulation Mode Pie Graph HH Grid Screen P Chart Historical data display Alarm 3 Timer Message Board coo Ill Recipe selector Ez Recipe data display atmega32 Ce Adobe Reader T mar pene ee Ty QuickStartTou After the Welcome screen it is possible to define others screen containing the wished infor mation by object Screen Button is easy to move to different screens then there are several objects to write a Text to insert a Picture to read write a variable from Instrument etc They are intuitive easy to use functions use the User manual for reference and the examples into the listed applications at the end of this document ALARM LOG In standard list project menu of SKWorkshop there is Alarm Log function In this page is possi ble to check the status of one bit for each digital alarm and the threshold upper or lower limit of one analog value for each analog alarm To see the log with the alarm status is necessary to create a screen putting an Insert top side main menu then Alarm then function Alarm Con trol or other similar available Note HMI Parameter Setting of project menu allows to set a beep sound in case of alarm
18. nitor Address LW32 Font System i Justification Zero Suppr Font Size 10 Leading Ze Total Digits 3 Leading Sp Fractional Digits 1 Macro Use Macro Macro Name Marco3 ID 3 Data Transfer Data Transfer Attribute Attribute Timed Timed 9 Triggered Trigger Bits LB2 Triggered Trigger Bits B4 Automatic Reset Automatic Reset Address Type Word m Address Type Number of Word ca Number of Word 1 T Source Addres 4x 16383 Source Addres LW62 Destination AdLW30 m Destination Adr4x 16385 NI HN p r e Invensys Eliwell Controls s r l Via dell Industria 15 e Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 11 www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 HISTORICAL DATA To collect data to be then used i e for graph select in the project menu the function Historical Data Logger in the following window select the variable to log and sampling details Historical data collector Genarel Name Historical Data Logger 0 Memory Sample Full Processing Sample tegi j Number of S 100 C Stop Sampling C Notify MemoryRequre2200 Remarks Memory Required 2 20 The total bytes of datatyp
19. r work with free family at the modbus address must be subtract 1 Work around BIT BUTTON To use BB to write the Boolean value must be convert in Integer with macro p r e Invensys Eliwell Controls s r l Via dell Industria 15 e Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 22 www eliwell com
20. t is necessary to compile the project by clicking on Knocker Image Then clicking on EL it is possible to download by USB or Ethernet cable the application DIAL SWITCH On the back of Touch Panel a rubber cover is present Under the cover 5 dial switch in OFF po sition as default are available Set dip 1 and 3 ON at successive power on the Touch Panel will show its internal set up in terms of IP address Time Date Backlight intensity etc Change the settings then turn OFF dip1 and dip2 At next power on the touch panel will work with new settings p r e Invensys Eliwell Controls s r l Via dell Industria 15 e Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 1 5 www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 DOWNLOADS Installation setup USB drivers and documentation are also available from the Restricted Area of the website www eliwell com http www eliwell it content aspx id 29991 once you have registered Available Literature USB DRIVERS Available downloads USE CASES Available downloads In the next pages a brief description of the Use Cases available NOTES Projects simulation shall be loaded on your PC at following path C SAMKOON Win 7 users Launch Samkoon exe tool and after that open relevant project use case
21. tion of screen is the core of develop the other things are the setting of HMI consider ing the wished connection with external devices In a screen page it is possible to put as objects as wished an object consist in images or gener al graphic items to compose to obtain a figure but overall numbers or information coming from or going to connected devices To switch between screens a screen button can be used See following example p r e Invensys Eliwell Controls s r l Via dell Industria 15 Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 7 www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 Define a starting Screen with only a picture for example an Eliwell logo right key of the mouse or by selecting Insert in the main menu then select Static Picture here you can select a picture from standard library or from your picture file a SKWorkshop C FreeSmart shm screenZ File F Edit E View Draw H Insert Screen P Setting S Do WS x y E Bit Button w Word Button il More Button Z HMI Parameter Setting Attribute A HMI Status ce PLC Control A Numerical Input Display E Clock Library gb ASCII Charater Display X utm Ctri x 38 ASCII Charater Entry Copy C Ctrl C 4 BitLamp Cg MultiState Switch Multistate Lamp 8s Message Disp
22. y 1 x100ms Run Times 0 Note if the execution times for m It means Function Function Type x Name Marco0 gt ID 0 IMPORTANT NOTE Data Transfer works in one direction only Source to Destination To update parameters or other itis mandatory to create another transfer between former Destination now Source to former Source now Destination in the next picture see a parameter definition where the read value is coming from internal storage LW32 and the written value is send to LW62 then exist 2 data transfer the first one involve LW32 as Destination from Source specified Instrument address the second one involve LW62 as Source to Destination the same specified Instrument address note also the macro Marco3 used to produce the triggering to send this transfer p r e Invensys Eliwell Controls s r l Via dell Industria 15 Zona Industriale Paludi e 32010 Pieve d Alpago BL ITALY Telephone 39 0437 986 111 e Fax 39 0437 989 066 Technical helpline 39 0437 986 250 E mail eliwell freeway invensys com page 1 0 www eliwell com eei Touch Graphical Interface Application Notes rel 30 07 13 s Nameric Entry General ID NE0000 Border Color FG Color BG Color Text Color Pattern Data Type 16 Bit Unsigned Int iv Display Type 16 Bit Unsigned Decimal iv Write Address LW62 Ez _ Monitor Address Identical to V Password i Mo

Download Pdf Manuals

image

Related Search

Related Contents

Philips D8479 User's Manual      Grundfos 96860172 Instructions / Assembly  MB SAFETY`  Utica Boilers BC Series II Operation and Installation Manual  Frigidaire FFEW2725PB Product Specifications Sheet  Metall-Detektor MD 3006 Bedienungsanleitung  Summit X480 Series Fixed Configuration Switches Data Sheet  Untitled  