Home

VACON NX QUICK HELP Start

image

Contents

1. CAN bus communication Application Control unit Device change Device added Device removed Device unknown IGBT temperature Encoder fault Device change default param Device added default param Division by zero application Analogue input lin lt 4mA selected signal range 4 20 mA External fault Keypad communication fault Fieldbus fault Slot fault PT100 temperature fault Identification Brake Follower communication Monitoring values Signal name Output frequency Frequency reference Motor speed Motor current Motor torque Motor power Motor voltage DC link voltage Unit temperature Motor temperature Voltage input Current input DIN1 DIN2 DIN3 DIN4 DIN5 DIN6 DO1 RO1 RO2 Analogue output current Multimonitoring items NOTE Different All in One applications embody more monitoring values Cooling Speed error UTER ETI Emergency stop Input switch open Actual value special display The Actual value special display parameters are used to convert and display the actual value signal in a form more informative to the user The Actual value special display parameters are available in P D Control Application and Pump and Fan Control Application ParID Parameter name Parameter code in Parameter code in PID ctrl applic Pump amp Fan ctrl applic ID1033 Actual value sp
2. 5 13 95 Hz RUN R CZ Yi GE 13 95 Hz Keypad shortcuts 1 Quick activation of keypad contol If you have selected either the I O terminal control 0 term or the fieldbus control Bus Comm as the active control place but wish to take over the control from these to the keypad this can be done in two different ways A Swap between keypad control and another control as active control place With the I O terminals or fieldbus selected as the active control place it is also possible to change the control to the local keypad and back to the original control place Irrespective of your location in the menu structure keep the a button pushed down for 5 seconds This will activate the Start amp Stop keypad control The display will jump to the editing mode of R3 2 Keypad Refer ence and you will be able to enter the desired frequency on the keypad Push the start button to start the drive Pushing the button again for 5 seconds returns the control to the original control place active control place P3 1 and its reference NOTE The motor starts if the start command of the active control place is ON and run at the formerly set reference The keypad display will show monitoring value V7 7 Output Frequency If any of the parameter values in menu M is changed in between the swapping the keypad reference will be reset to 0 00 Hz B Activate the keypad control and copy the output reference to the keypad When motor is runni
3. VACON NX QUICK HELP Start up wizard The Start Up Wizard is activated when the power to the drive is turned on for the first time or if the Start Up Wizard is activated from the System menu P6 5 3 AND the power is turned OFF and back ON The Start up Wizard is a feature on the control keypad to facilitate the commissioning of the fre quency converter If selected active default the Start up Wizard prompts the operator for the lan guage and application of his her choice plus for the values for a set of parameters common to all applications as well as for a set of application dependent parameters Always accept the value with the Enter button scroll options or change values with the Browser buttons up and down arrows More information on the use of the control panel in Chapter 7 of the User s Manual Startup wizard Press enter Language English Application Standard Setup starts Press enter Repeat setup lt No Yes gt Min Frequency 0 00 Hz Faults and fault codes Overcurrent Overvoltage Charging switch Emergency stop Saturation trip System fault Brake chopper supervision Frequency converter under temperature Frequency converter overtemperature Motor stalled Motor overtemperature Motor underload Unbalance EEPROM checksum fault Counter fault Microprocessor watchdog fault Start up prevented Safe Disable IGBT temperature hardware Fan cooling
4. ecial display minimum 2 2 46 2 9 29 ID1034 Actual value special display maximum 2 2 47 2 9 30 ID1035 Actual value special display decimals 2 2 48 2 9 31 ID1036 Actual value special display unit 2 2 49 2 9 32 Example The actual value signal sent from a sensor in mA represents the amount of waste water pumped from a tank per second The signal range is 0 4 20mA Instead of receiving the level of the actual value signal in mA on the display you wish to receive the amount of water pumped in m s You then set a value for par ID1033 to correspond to the minimum signal level 0 4 mA and another value for par ID1034 to correspond to the maximum signal level 20 mA The number of decimals needed can be set with par ID1035 and the unit m s with par ID1036 The level of the actual value signal is then scaled between the set min and max values and displayed in the selected unit The following units can be selected par ID1034 0 NotUsed o1 A ae ENS NEMO CNANO Pp m Pd Ea ee ae eee m3 min NOTE The maximum number of characters that can be shown on keypad is 4 This means that in i qe dj F o 18 gal s 19 gal min some cases the display of the unit on the keypad does not comply with the standards Selection of language Find the System Menu M6 Enter the Language selection page S6 1 Push the Menu button rightto make the name of language blink Browse t
5. hrough the languages with the Browser buttons and select another language with the Enter button foe Donc For closer information on language selection see User s Manual Chapter 7 3 6 READY READY Mp S5 Gi S ystem Menu Language 12 811 English READY o5 GED Language English Selection of application Find the System Menu M6 Enter the Application selection page S6 2 Push the Menu button rightto make the name of application blink Browse through the applications with the Browser buttons and select another application with the Enter button Feba ma For closer information on application change see User s Manual Chapter 7 3 6 cody M5 cho GE System Menu Application S19S11 Standard CEDG Shc ED Application Application Standard Multi step Control panel menus gp P I Expander boards G13G5 Mp m System Menu 512359 READY wo Fault history H129H3 M4 Active faults FO M3 Keypad control P123 P3 READY we lt p Parameters G13G9 MI Monitor V12V15 aad cD lt p gt Output frequency cep ce 611 6711 P A NXOPTA1 Parameters G1 gt G1 P19P3 STOP READY READY S6 m Change p Language value English P3 lt P Control Place Change A Browse value O Terminal Qa gy READY bc D A Pe 1c lt P Basic parameters P Min Frequency Change A B rowse value P19P1
6. ng Keep the button pushed down for 3 seconds The keypad will become the active control place and the current frequency reference and direction will be copied to the keypad When motor is stopped Keep the button pushed down for 3 seconds The keypad will become the active control place and the current frequency reference and direction will be copied to the keypad These features will not work unless you are in menu M3 If you are in any other than M3 menu and try to start the motor by pressing the START button when the keypad is not selected as the active control place you will get an error message Keypad Control NOT ACTIVE If you are in any other than M3 menu and press the STOP button the motor will stop See point 3 below QQQ 2 Copy elsewhere set frequency reference to keypad Copy the frequency reference set elsewhere 1 0 fieldbus to the keypad by keeping the button pushed down for 3 seconds This shortcut will not change control places This feature will not work unless you are in menu M3 QQQ 3 Stopping the drive regardless of the active control place By default the motor can be stopped at all times by pushing the e button regardless of the selected control place This default setting can be inactivated by giving parameter Stop Button Activated P3 4 or P3 6 menu M3 the value 0 With this value given to the parameter pushing the STOP button stops the motor only when the keypad has been selected as the active control
7. place