User Manual - QED Productions
Contents
1. Velocity Digital Video Extension System 6 Dual Link DVI Transmitter STEP 5 Connect the video source M CPU to the Tx with the supplied 2 meter DVI D M M Dual Link Cable CBL 000023 002MR A local display can also be connected using a similar Transmitter DVI D M M Dual Link cable Local ST SC or LC type Optical Fibers up to 1000 meters Monitor L1 Data Tx to Rx amp Video Primary L2 Data Rx to Tx L3 Video Secondary STEP 3 Connect the fiber optic cables between the Rx and Tx units STEP 2 Connect the supplied AC Power Adapter PWR 000022 R to the Rx and plug it into a standard AC source Power Supply PWR 000022 R thinklogical Velocity Digital Video Extension System 6 Dual link DVI Receiver DVI to Display DDC DVI to Display Lower Connector Upper Connector L3 Video L2 lt Data L1 Video Data Powered by Technology Receiver eueve Projector Secondary i P STEP 1 Connect the Rx Primary Port to a projector Primary Due Port di video monitor or other viewing device with a DVI D M 5 M Dual link Cable A second device can be installed using a similar cable Turn the DVI video devices ON June 2010 45 REVISION D thinklogical A 4 VEL 6 Velocitydvi Digital Video Extender 6 A V Installation Overview STEP 4 Connect the supplied AC Powe
2. 37 5 1 Safely Regq ire ments a de ee med Mle a an oam edo oe t a us 37 5 1 1 Symbols Found on Our Products ec eren ie eade ket 37 5 1 1 1 Class 1 Laser Labeling mE 37 5 2 Regulatory Compliance da 37 5 2 A Norti America i RIA e niens 37 5 2 2 Australia amp New Zealand sees eene memes 38 5 2 9 European Uhlons iniecto Hn ege A ge ee ee es 29 5 2 3 1 Declaration of Conformity 38 5 2 3 2 Standards With Which Our Products Comply 38 5 2 4 Supplementary Information i nti 39 5 2 5 Product Serial Number ci Itb ea fete gute ote ta nes a o aes Tea tab a 39 June 2010 3 REVISION D thinklogical 6 How to Contact ina iu sis asian a a i O d a a i i i i 40 6 1 Customer SUD DOM ins A i ki is 40 40 G 2 Email ERE kas ia 421 1 o 40 64 Telephone eet d de Paquete dd Conte mcd ert 40 que 225 454585 55424556 anas N 41 6 2 Product Cm 41 6 2 1 Wa
3. 5031 501 15 XL 01 X4 Jeqy ON Bulusel ejge yoq 10 X XH UI ou 5 poN OLIS 12907 peusiiqeise 9014 MalLIWSNVHL saa1snivis XL SHUN JOJJILISUBJI y 0 Seoinos 1ndlno ay j12euuoo ol peijddns y 9 4315 ug pearbopyury REVISION D 48 June 2010 thinklogical Appendix B DVI Extender Mounting Each VelocitvDVI Extender 3 and 6 can be used as a desk top or wall mounted device Mounting centers are provided with kevhole slots Users mav choose the most appropriate fasteners and anchors to mount each unit according to the requirements of each application VelocityDVI 33 and 63 chassis can be desk top feet provided or standard EIA 19 rack mounted Be sure to leave adequate clearance 3 inch minimum bend radius for your Fiber Cable 3 inches minimum UNIT Vel 3 Short Body Vel 3 Long Body Vel 3 with Neutrik Vel 3 AV Short Vel 3 AV Long Vel 3 AV w Neutrik Vel 3 AN Vel 3 AN w Neutrik Vel 6 Vel 6 with Neutrik Vel 6 AV Vel 6 AV w Neutrik Vel 6 AN Vel 6 AN w Neutrik Vel 33 rack mount Vel 63 rack mount June 2010 4 thinklogical Velocity D
4. LCL REM SERIAL OUT DVI to Display DDC DVI to Display a thinklogical The Future of access and Control Velocity Digital Video Extension System 3 A V with Neutrik Connector Transmitter DVI from CPU Video Data lt L1 Neutrik Connector Data gt L2 gt S a 2 a ri 9 a e 8 Powered by Technology FIGURE 8 Velocity 3A V with Neutrik OpticalCon DUO Connector June 2010 19 REVISION D thinklogical 5 0 0 o d Contro 8 gt n 5 AM D 5 NM a a 0 6 O DVI to Local Display a e E o a a 7 00 177 80mm L x 7 49 190 25mm W x 1 10 27 94mm H On the RJ45 connector Network Status LEDs 100 10 Green LED Link When lit speed of link is 100 Mb Yellow LED blinking Activity When off speed of link is 10 Mb FD COL When lit indicates operation in Full Duplex When off indicates operation in Half Duplex When blinking indicates Collision FIGURE 9 Velocity 3 A N Transmitter June 2010 20 REVISION D thinklogical Velocity 3 A N Receiver Audio Network DVI to Dlsplay DVI to Display DDC E o a a Receiver On the RJ
5. DVI from CPU DVI to Local Display o E 7 75 196 85mm L 7 49 190 25mm W 2 00 50 80mm H On the RJ45 connector Network Status LEDs 100 10 Green LED Link When lit speed of link is 100 Mb Yellow LED blinking Activity When off speed of link is 10 Mb FD COL When lit indicates operation in Full Duplex When off indicates operation in Half Duplex When blinking indicates Collision FIGURE 19 Velocity 6A N Transmitter with Neutrik amp QUAD Connector June 2010 30 REVISION D thinklogical DVI to Display DVI to Display DDC o 7 75 196 85mm L 7 49 190 25mm W 2 00 50 80mm H On the RJ45 connector Network Status LEDs 100 10 Green LED Link When lit speed of link is 100 Mb Yellow LED blinking Activity When off speed of link is 10 Mb FD COL When lit indicates operation in Full Duplex When off indicates operation in Half Duplex When blinking indicates Collision FIGURE 20 Velocity 6A N Receiver with Neutrik amp QUAD Connector June 2010 31 REVISION D thinklogical CAUTION Replace with same type and rating fuse E Ig i DDCMODE MODE DDC MODE CN E facauine ununun mmmuusam _ FIN n O Ot OI r HHH eo AN
6. YALLINSNVYL aaow NI IAC SHUN eui 1ndlno oepiA ay joeuuoo seilge Perddns eui 9 4316 Jeorboprury ical 01 thinklo A 6 VEL 63 NO y pue 106 Ov 5 ejoeydeoe 5 01 H 900000 HMd P109 Ov pailddns y uonisod 0 440 eui U SI U9IIMS JEU ensu3 2 4315 OVA Gunes pue ewes ym exerde siumo 1941 jo y aaas pue VS eui ur POJUUH siu u 6002 14044400 uod 81110 si LNO IAQ sured eui jo 104 5 NO IAG 8 0 ndino peursep y q IAG prepueis Buisn 4315 2 001 19388 7 101 ee A suinoov oaa 0001 01 dn 54841 jeondo d y ens eq pue sajqeo eui youd 10 JOU oq s191SW 0001 0 dn siu xg pue eur ugamjaq sejqeo ondo
7. The EDID table can be loaded before the TX is installed Limitations No communication link from the CPU to the display This prevents the use of HDCP or monitor configuration color tuning and may result in loss of remote video if a display with lower resolution capability is connected to the RX 3 1 3 Load Default EDID Table Holding both buttons for 5 seconds will reload the default DDC table into the TX and switch the DDC mode to Remote Static The TX Status LED will turn Orange while the default table is loaded and then change to Green Advantages Sends a valid EDID table to the CPU in order for the graphics adapter to boot Limitations Default EDID table may not support required resolutions Feature Remote Remote Pass Thru Local Static Load Default Dynamic Static mde No No Yes No No HDCP Supports No No Yes No No monitor alibration No No Yes No No EDID table Yes Yes Yes No No loaded from Rx EDID table No No No Yes No loaded from x EDID table Yes Yes No Yes Yes tored in non volatile memory Fibers 2 2 initially 2 1 1 required then L1 only System 3 Fibers 3 3 initially 3 2 2 required then L1 and ystem 6 L3 only TABLE 2 EDID Capability Summary June 2010 34 REVISION D thinklogical 3 1 4 DDC LEDs and Mode Button Operation DDC MODE ACQUIRE TX LCL REM SELECT e Acquire Button The upper button is the Acquire Button This button is use
8. The receiver unit provides an interface to the monitor s and audio serial amp network devices in A V and A N models Each Transmitter TX features a video input and local video output which can be used for DDC modification and for displaying video at the source The TX also has fiber connectors used for transferring video and data to the Receiver Status LEDS and DDC Mode buttons are provided for system configuration Each Receiver RX features 2 video outputs The DVI to Display DDC output on the left looking at the back of the unit is the primary output The RX also has fiber connectors used for transferring data to the TX and receiving video and data from the TX Status LEDS and DDC Mode buttons are provided for system configuration June 2010 5 REVISION D thinklogical thinklogical Velo Velocitydvi 19 ri Digital Video Extension System 3 Single Link DVI Single Link DVI Receiver 114 Video Data Powered by ideo Data Powered by MRTS Technology MRTS Technology VEL 3 Transmitter VEL 3 Receiver Velocitydvi Digital Video Extender 3 thinklogical 4 Velocityc v Velocitycvi Digital Video Extension System 6 2 Digital Video Extension System 6 Dual Link DVI Transmitter Dual Link DVI Receiver Lower Connectors Upper tor L1 4 Video Data 12 Data L3 lt Video Powered by L1 gt Video Data Powered by MRTS Tec
9. x o 0 0 l 1 P o d Contro EK X DVI from CPU DVI to Local Display o a a 7 00 177 80mm L x 7 49 190 25mm W x 1 10 27 94mm H On the RJ45 connector Network Status LEDs 100 10 Green LED Link When lit speed of link is 100 Mb Yellow LED blinking Activity When off speed of link is 10 Mb FD COL When lit indicates operation in Full Duplex When off indicates operation in Half Duplex When blinking indicates Collision FIGURE 17 Velocity 6A N Transmitter June 2010 28 REVISION D thinklogical E e 100 10 e gt o MN WU o E ll D a W 5 a 0 e Did deo O R 8 d b 5 5 8 ej eje u Q T g e a o o a 7 00 177 80mm L x 7 49 190 25mm W x 1 10 27 94mm H On the RJ45 connector Network Status LEDs 100 10 Green LED Link When lit speed of link is 100 Mb Yellow LED blinking Activity When off speed of link is 10 Mb FD COL When lit indicates operation in Full Duplex When off indicates operation in Half Duplex When blinking indicates Collision FIGURE 18 Velocity 6A N Receiver June 2010 29 REVISION D thinklogical
10. 3y 10994100 d31S faepuooes z o piA 6 9 7 sse sejoejdeoo4 110 IAG y eui joeuuoo 5 PJEPUEJS 6 4316 XL O XH eleq 8 S ZT pue XH XI Z y 17 Auedoud Bugeiedo SUOIJJUN 5 5 184 eansu3 NO y uin pue eounos OV pJepueis B ojui eui 4 900000 HMd p109 OV perddns 0 440 ay UI S U9 IMS 124 einsu3 5 4315 OVA OSZ YZL H 09 05 6 0 002 001 esny pue edi ewes uj eot 100 _ BI 1110 zano 1110 LIAG me dom see 3unoov 900 NI IAG T NIZIAQ 110 auinoov oaa AGINS LYVLS W9JSAS uolsu 1x3 o piA IAPAJDOJSA e XH 01 X ON Bulysey pod pejoeuuoo JAQ ON JONVHO pajege uod 1NO IAG xui poo seu
11. 4315 4 LNO 95 25 aaow 1 101 R zanor NI IAQ ass a ee pue aaow 199135 1 9 e 281110 LIAG 5 MOINS UI9 S S O9PIA 199195 1 101 ee aaow S10 99UU023 ad 91 10 9S 16 oapiA 5 0001 01 dn 9414 jeondo OGG 10 SI Y uo 0 SUL e XH 01 X ON Sejoeideoe1 reuiud JOHUOW JAQ ON 3ONYHO LNO IAG L pelegel uod 1NO 1ndino IAG Alewlid sey JOHUOW N33H9 O9PIA eui 12euuoo saa1snivis tm TAg XL 01 XY ON peljddns Buisn 6 4315 nu umop 10 X XH Jeg ou pejoejes 1215 901 39NVHO peusiiqeise poof pejoeuuoo 9014 5031 SNLVLS XL
12. Class 1 digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment uses generates and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications in which case the user may be required to correct the interference A NOTE This Class 1 digital apparatus complies with Canadian ICES 003 and has been verified as compliant within the Class A limits of the FCC Radio Freguency Device Rules FCC Title 47 Part 15 Subpart B Class A measured to CISPR 22 1993 limits and methods of measurement of Radio Disturbance Characteristics of Information Technology Eguipment This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Cet appareil numerique de la classe A respecte toutes les exigencies du Reglement sur le material brouilleur du Canada A wore The user may notice degraded audio performance in the presence of electro magnetic fields 5 2 5 Product Serial Number The VelocityDVI Extender products have a unique serial number imprinted on a small silver label that is placed on the bottom of the chassis The serial number includes a date code The format for the date code is two digits for the month two digits for the day and two digi
13. DUAL FIBER 50M OR 350M OR 1000M SC OR ST VEL 000M06 LCRX VELOCITY 6 DVI VIDEO EXTENDER DUAL LINK DVI AUX DUAL DVI OUTPUT DDC MULTIMODE RX LC VEL 000M06 LCTX VELOCITY 6 DVI VIDEO EXTENDER LOCAL DUAL DVI PORT DDC MULTIMODE TX LC June 2010 8 REVISION D thinklogical VEL 000M06 SCRX VELOCITY 6 DVI VIDEO EXTENDER DUAL LINK DVI AUX DUAL DVI OUTPUT DDC MULTIMODE RX SC VEL 000M06 SCTX VELOCITY 6 DVI VIDEO EXTENDER LOCAL DUAL DVI PORT DDC MULTIMODE TX SC VEL 000M06 STRX VELOCITY 6 DVI VIDEO EXTENDER DUAL LINK DVI AUX DUAL DVI OUTPUT DDC MULTIMODE RX ST VEL 000M06 STTX VELOCITY 6 DVI VIDEO EXTENDER LOCAL DUAL DVI PORT DDC MULTIMODE TX ST VEL 000M63 LCRX 3 in 1 VELOCITY 6 DVI VIDEO EXTENDER DUAL LINK DVI AUX DUAL DVI OUTPUT DDC MULTIMODE RX LC VEL 000M63 LCTX 3 in 1 VELOCITY 6 DVI VIDEO EXTENDER LOCAL DUAL DVI PORT DDC MULTIMODE TX LC VEL 000M63 SCRX 3 in 1 VELOCITY 6 DVI VIDEO EXTENDER DUAL LINK DVI AUX DUAL DVI OUTPUT DDC MULTIMODE RX SC VEL 000M63 SCTX 3 in 1 VELOCITY 6 DVI VIDEO EXTENDER LOCAL DUAL DVI PORT DDC MULTIMODE TX SC VEL 000M63 STRX 3 in 1 VELOCITY 6 DVI VIDEO EXTENDER DUAL LINK DVI AUX DUAL DVI OUTPUT DDC MULTIMODE RX ST VEL 000M63 STTX 3 in 1 VELOCITY 6 DVI VIDEO EXTENDER LOCAL DUAL DVI PORT DDC MULTIMODE TX ST VEL AV0S06 SCRX VELOCITY 6 A V DVI VIDEO EXTENDER DUAL DVI AUX DUAL DVI OUTPUT DDC SERIAL AUDIO SINGLEMODE RX SC APC VEL AV0S0
14. DVI VIDEO EXTENDER DUAL LINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTIMODE TX NEUTRIK VOP M05 VELOCITY 6 OPTICS OPTION FOR TX OR RX MULTIMODE 3 FIBERS 50M OR 350M OR 1000M LC OR NEUTRIK LC June 2010 9 REVISION D thinklogical VOP M02 VELOCITY 6 AV OPTICS OPTION FOR TX OR RX MULTIMODE 3 FIBERS 50M OR 350M OR 1000M SC OR ST VEL AN0S06 SCRX VELOCITY 6 A N DVI VIDEO EXTENDER DUAL LINK DVI AUX DUAL DVI OUTPUT DDC SERIAL AUDIO SINGLEMODE RX SC APC VEL AN0S06 SCTX VELOCITY 6 A N DVI VIDEO EXTENDER DUAL LINK DVI LOCAL DUAL DVI PORT DDC SERIAL AUDIO SINGLEMODE TX SC APC VEL AN0S06 NKRX VELOCITY 6 A N DVI VIDEO EXTENDER DUAL LINK DVI AUX DUAL DVI OUTPUT DDC SERIAL AUDIO SINGLEMODE RX NEUTRIK LC VEL AN0S06 NKTX VELOCITY 6 A N DVI VIDEO EXTENDER DUAL LINK DVI LOCAL DUAL DVI PORT DDC SERIAL AUDIO SINGLEMODE TX NEUTRIK LC VOP S08 VELOCITY 6 OPTICS OPTION FOR TX OR RX SINGLEMODE 3 FIBERS 10KM SC APC VOP S12 VELOCITY 6 A N OPTICS OPTION FOR TX OR RX SINGLEMODE 3 FIBERS 10KM NEURTIK LC APC VEL ANOMO6 LCRX VELOCITY 6 A N DVI VIDEO EXTENDER DUAL LINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX LC VEL ANOMO6 LCTX VELOCITY 6 A N DVI VIDEO EXTENDER DUAL LINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTIMODE TX LC VEL ANOMO6 SCRX VELOCITY 6 A N DVI VIDEO EXTENDER DUAL LINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX SC VEL ANOMO6 SCTX VELOCI
15. RX The RX cannot send any information to the TX In this mode the RX buttons are inoperative Also DDC information can only be gathered from the TX local port or the Thinklogical default EDID table 2 4 Dual Fiber Operation System 3 In this mode video information is transmitted from the TX to the RX over fiber L1 Fiber L2 is used as a data return path from the RX to the TX Providing a back channel from the RX to the TX allows the RX to modify DDC configuration via the Acquire and Select buttons and allows the RX to send DDC information to the TX DDC information exchange allows the PC to gather information about the connected monitor to determine the display properties 2 5 Fiber Operation System 6 System 6 operates in Dual fiber or Triple fiber operation In dual fiber operation fibers L1 and L3 are used to transmit data and video from the TX to the RX and in three fiber mode fiber L2 transmits data from the RX back to the TX 2 6 Technical Specifications Systems 3 6 33 and 63 TABLE 1 Technical Specifications Systems 3 6 33 63 Video Resolution Vel 3 Any single link DVI resolution Vel 6 Any single link or dual link DVI resolution Panel Connections Transmitter Video DVI D 2 Power 2 5 mm power connector Fiber Connections ST SC or LC Receiver Video DVI D 2 Power 2 5 mm power connector Fiber Connections ST SC or LC e e LIL 0 50 C 32 122 F 5 95 RH non condensing
16. VELOCITY 3 SINGLE LINK DVI DDC MULTIMODE TX ST VEL 000M33 LCRX 3 in 1 VELOCITY 3 SINGLE LINK DVI DDC MULTIMODE RX LC VEL 000M33 LCTX 3 in 1 VELOCITY 3 SINGLE LINK DVI DDC MULTIMODE TX LC VEL 000M33 SCRX 3 in 1 VELOCITY 3 SINGLE LINK DVI DDC MULTIMODE RX SC VEL 000M33 SCTX 3 in 1 VELOCITY 3 SINGLE LINK DVI DDC MULTIMODE TX SC VEL 000M33 STRX 3 in 1 VELOCITY 3 SINGLE LINK DVI DDC MULTIMODE RX ST VEL 000M33 STTX 3 in 1 VELOCITY 3 SINGLE LINK DVI DDC MULTIMODE TX ST VEL AV0S03 SCRX VELOCITY 3 A V DVI VIDEO EXTENDER SINGLE LINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO SINGLEMODE RX SC APC VEL AV0S03 SCTX VELOCITY 3 A V DVI VIDEO EXTENDER SINGLE LINK DVI LOCAL DVI OUTPUT DDC SERIAL AUDIO SINGLEMODE TX SC APC VEL AV0S03 NKRX VELOCITY 3 A V DVI VIDEO EXTENDER SINGLE LINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO SINGLEMODE RX NEUTRIK LC VEL AV0S03 NKTX VELOCITY 3 A V DVI VIDEO EXTENDER SINGLE LINK DVI LOCAL DVI VOP S05 VOP S11 VEL AVOM03 LCRX VEL AVOMO3 LCTX VEL AVOM03 SCRX VEL AVOM03 SCTX June 2010 OUTPUT DDC SERIAL AUDIO SINGLEMODE TX NEUTRIK LC VELOCITY 3 AV OPTICS OPTION FOR TX OR RX SINGLEMODE DUAL FIBER 10KM SC APC VELOCITY 3 AV OPTICS OPTION FOR TX OR RX SINGLEMODE DUAL FIBER 10KM NEUTRIK LC VELOCITY 3 A V DVI VIDEO EXTENDER SINGLELINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX LC VELOCITY 3 A V DVI VIDEO E
17. amp Video 3 5mm Audio cables and the L2 Data Rx to Tx RJ45 CAT5 cable STEP 3 Connect the fiber optic cables between the Rx and Tx units DVI to Local Display DVI from CPU L1 lt Video Data Transmitter STEP 2 Connect the supplied AC Power Adapter PWR 000022 R to the Rx and plug it into a standard AC source Power Supply PWR 000022 R thinklogical The Fi Serial Port External Lighting sensors etc Velocit hz Digital Video hil S 3 A V LESI STEP 1 Connect the Rx Primary Port to a projector video monitor or other viewing device with a DVI D M M Cable A secondary device can be installed using a similar cable Connect your Mic IN Line OUT and CAT5 Serial devices to the appropriate Receiver i Receiver LO ports Turn the Secondary devices ON Device Projector Primary DDC Port Receiver DVI to Display DDC DVI to Display 12 lt Data 11 Video Data Powered by Technology June 2010 44 REVISION D thinklogical A 3 VEL 6 Velocitv dvi Digital Video Extender 6 Installation Overview STEP 4 Connect the supplied AC Power Adapter PWR 000022 R to the Tx and CPU plug it into a standard AC source Power Supply PWR 000022 R thinklogical DVI Local Display DVI from CPU
18. and Humidity Storage Temperature 20 to 70 C 4 to 158 F Indicators LEDs on each DVI Extender unit Front Power Connection Status Rear DDC Modes Local Remote 1 Ib 0 45 kg each Vel 3 Vel 6 4 Ib 1 81 kg each Vel 33 Vel 63 Dimensions See page 13 Shipping Weight 4 Ib 1 81 kg pair Vel 3 Vel 6 13 Ib 5 89 kg pair Vel 33 Vel 63 Weight June 2010 12 REVISION D Optical Cable Optical Distance Supply Voltage Power Consumption DC Adapter DB9 to RJ45 Adapters Copper Video Cables Compliance Warranty UNIT Vel 3 Short Body Vel 3 Long Body Vel 3 with Neutrik Vel 3 AV Short Vel 3 AV Long Vel 3 AV w Neutrik Vel 3 AN Vel 3 AN w Neutrik Vel 6 Vel 6 with Neutrik Vel 6 AV Vel 6 AV w Neutrik Vel 6 AN Vel 6 AN w Neutrik Vel 33 rack mount Vel 63 rack mount June 2010 thinklogical Sys 3 2 fibers Sys 33 6 fibers Sys 6 3 fibers Sys 63 9 fibers available not supplied Up to 350 meters using 50 125um type OM2 Up to 1000 meters using 50 125um type OM4 Up to 10 kilometers using 9 125um 45 0 VDC Vel 3 Vel 6 90 264 VAC Vel 33 Vel 63 6 watts per unit Vel 3 Vel 6 20 watts per unit Vel 33 Vel 63 AC DC adapter universal input 90 264 VAC supplied Vel 3 6 With AV models only DB9M to RJ45 ADP 000019 R DB9F to RJ45 ADP 000025 R CBL000009 002MR Single link DVI D Male to Male 2 me
19. is now possible to position your monitor or projector in any setting from office to lecture hall to boardroom while keeping the computer secure in a remote controlled location Each DVI Extender system includes the following features e Supports one Single Link System 3 or one Dual Link System 6 video signal e Supports three Single Link System 33 or three Dual Link System 63 video signals e DDO2B compliant e Extends DVI up to 1000 meters 3280 feet using OM4 multi mode fiber e Signal transmission via fiber optic cable no RF interference e Flawless image quality with no frame dropping e Class 1 laser product e Simple plug and play e Small form factor 2 2 Basic operation The unit transmits video and data information from the Transmitter to the Receiver through fiber L1 The data return path from the Receiver to the Transmitter is fiber L2 VelocitydviDigital Video Extender 3 Installation Overview Transmitter Receiver Output ill Monitor i Power Supply Power Supply PWR 000022 R PWR 000022 R thinklogical tl MEL thinklogicalr L1 L1 and L2 L2 ST SC or LC type Optical Fibers m M up to 1000 meters Projector Primary DDC Port FIGURE 2 VelocitvDVI Extender Overview June 2010 11 REVISION D thinklogical 2 3 Single Fiber operation System 3 The unit will operate with a single fiber from the TX to the RX In this mode of operation the TX can transmit video and status LED information to the
20. of our representatives at any time Each of our sales and service representatives has a direct number to accommodate your calls 6 1 4 Fax Our company facsimile number is 1 203 783 9949 Please indicate the nature of the fax on your cover sheet and provide return contact information including your phone number 6 2 Product Support Thinklogical s support personnel are available Monday through Friday from 8 30am to 5 30pm Eastern Time Zone If you require assistance at some time outside of our normal business hours please contact us beforehand and we will do our best to make arrangements to assist you 6 2 1 Limited Warranty Information Thinklogical LLC Thinklogical warrants this product against defects in materials and workmanship for a period of one 1 year from the date of delivery ordinary wear and tear excluded This limited warranty does not cover defects resulting from i use of the product other than as described in the applicable documentation for the product ii modifications to or repairs of the product that are made by any party other than Thinklogical or a party acting on Thinklogical s behalf or iii combination of the product with third party products that is not consented to by Thinklogical Occurrences of events described in i iii shall void the foregoing warranty This warranty gives you specific legal rights and you may also have other rights which vary from state to state Except for the expres
21. on pages 43 48 Appendix B DVI Extender Mounting on page 49 and Appendix C RJ 45 Adapter Pin outs on page 50 5 Regulatory and Safety Compliance 5 1 Safety Requirements 5 1 1 Symbols Found on Our Products Markings and labels on our products follow industry standard conventions Regulatory markings found on our products comply with all domestic and many international requirements 5 1 1 1 Class 1 Laser Labeling The DVI Extenders models VEL 3 6 33 and 63 are designed and identified as Class 1 LASER products CLASS 1 LASERS do not require any special precautions under conditions of normal use 52 Regulatory Compliance Thinklogical VelocityDVI Extender products are designed and made in the USA VelocityDVI Extender products have been tested by a nationally recognized testing laboratory and found to be compliant with the following standards both domestic USA and many international locations 5 2 1 North America These products comply with the following standards Safety ANSI UL60950 1 1 Edition 2003 CAN CSA C22 2 No 60950 1 03 Laser Safety CDRH 21 CFR 1040 10 Class 1 Laser Product VEL 3 VEL 6 VEL 33 VEL 63 Accession Number TBD June 2010 37 REVISION D thinklogical Electromagnetic Interference FCC CFR47 Part 15 Class A Industry Canada ICES 003 Issue 2 Revision 1 5 2 2 Australia amp New Zealand This is a Class A product In a domestic environment this pr
22. thinklogical Velocity 3 A V Short 1 10 TRANSMITTER 27 94mm DVI to Local Display DVI from CPU DDC MODE p V Ga STATUS ACQUIRE MIC LINE oo o LCL REM SERIAL OUT IN PONES C I 1 10 RECEIVER 27 94mm DVI to Display DDC DVI to Display DDC MODE Fi STATUS ACQUIRE 1 MIC LINE 4 LCL REM SERIAL IN OUT POWER 5 C ET m 09 061 094 01 991 0S 9 h 7 00 4 177 80mm Physical dimensions are the same for both the Transmitter and Receiver chassis FIGURE 6 Velocity 3 A V Short Body June 2010 17 REVISION D thinklogical Velocity 3 A V Long TRANSMITTER DVI from CPU DVI to Local Display 6 STATUS 2 DDC MODE ACQUIRE POWER Q 5 WY RECEIVER STATUS POWER BN 5 WY FIGURE 7 Velocity 3A V Long Body June 2010 18 REVISION D thinklogical Velocity 3 A V with Neutrik OpticalCon DUO Connector TRANSMITTER POWER 5VDC DDC MODE ACQUIRE e LCL REM SELECT SERIAL DVI to Local Display DVI from CPU RECEIVER DDC MODE AGQUIRE N MIC LINE
23. 3 A N DVI VIDEO EXTENDER SINGLE LINK DVI LOCAL DVI OUTPUT DDC SERIAL AUDIO SINGLEMODE TX NEUTRIK LC VOP S05 VELOCITY 3 A N OPTICS OPTION FOR TX OR RX SINGLEMODE DUAL FIBER 10KM SC APC VOP S11 VELOCITY 3 A N OPTICS OPTION FOR TX OR RX SINGLEMODE DUAL FIBER 10KM NEUTRIK LC VEL ANOMO3 LCRX VELOCITY 3 A N DVI VIDEO EXTENDER SINGLELINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX LC VEL ANOMO3 LCTX VELOCITY 3 A N DVI VIDEO EXTENDER SINGLELINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTIMODE TX LC VEL ANOMO3 SCRX VELOCITY 3 A N DVI VIDEO EXTENDER SINGLELINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX SC VEL ANOMO3 SCTX VELOCITY 3 A N DVI VIDEO EXTENDER SINGLELINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTIMODE TX SC VEL ANOMO3 STRX VELOCITY 3 A N DVI VIDEO EXTENDER SINGLELINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX ST VEL ANOMO3 STTX VELOCITY 3 A N DVI VIDEO EXTENDER SINGLELINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTIMODE TX ST VEL ANOMO3 NKRX VELOCITY A N DVI VIDEO EXTENDER SINGLELINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX NEUTRIK VEL ANOMO3 NKTX VELOCITY 3 A N DVI VIDEO EXTENDER SINGLELINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTIMODE TX NEUTRIK VOP M04 VELOCITY 3 OPTICS OPTION FOR TX OR RX MULTIMODE DUAL FIBER 50M OR 350M OR 1000M LC OR NEUTIK LC VOP M01 VELOCITY 3 A N OPTICS OPTION FOR TX OR RX MULTIMODE
24. 45 connector Network Status LEDs 100 10 Green LED Link When lit speed of link is 100 Mb When off speed of link is 10 Mb FD COL When lit indicates operation in Full Duplex J9Al929H When off indicates operation in Half Duplex When blinking indicates Collision FIGURE 10 Velocity 3 A N Receiver June 2010 21 REVISION D thinklogical 100 DVI from CPU DVI to Local Displav 5 a a 7 00 177 80mm L x 7 49 190 25mm W 2 00 50 80mm On the RJ45 connector Network Status LEDs 100 10 Green LED Link When lit speed of link is 100 Mb Yellow LED blinking Activity When off speed of link is 10 Mb FD COL When lit indicates operation in Full Duplex When off indicates operation in Half Duplex When blinking indicates Collision FIGURE 11 Velocity 3 A N Transmitter with Neutrik amp DUO Connector June 2010 22 REVISION D y thinklogical DVI to Display DVI to Display DDC o 7 00 177 80mm L 6 50 165 10mm W x 1 10 27 94mm On the RJ45 connector Network Status LEDs 100 10 Green LED Link Yellow LED blinking Activity When lit speed of link is 100 Mb When off speed of link is 10 Mb FD COL When lit indi
25. 6 SCTX VELOCITY 6 A V DVI VIDEO EXTENDER DUAL LINK DVI LOCAL DUAL DVI PORT DDC SERIAL AUDIO SINGLEMODE TX SC APC VEL AVOS06 NKRX VELOCITY 6 A V DVI VIDEO EXTENDER DUAL LINK DVI AUX DUAL DVI OUTPUT DDC SERIAL AUDIO SINGLEMODE RX NEUTRIK LC VEL AV0S06 NKTX VELOCITY 6 A V DVI VIDEO EXTENDER DUAL LINK DVI LOCAL DUAL DVI PORT DDC SERIAL AUDIO SINGLEMODE TX NEUTRIK LC VOP S08 VELOCITY 6 OPTICS OPTION FOR TX OR RX SINGLEMODE 3 FIBERS 10KM SC APC VOP S12 VELOCITY 6 AV OPTICS OPTION FOR TX OR RX SINGLEMODE 3 FIBERS 10KM NEURTIK LC APC VEL AVOM06 LCRX VELOCITY 6 A V DVI VIDEO EXTENDER DUAL LINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX LC VEL AVOM06 LCTX VELOCITY 6 A V DVI VIDEO EXTENDER DUAL LINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTIMODE TX LC VEL AVOMO6 SCRX VELOCITY 6 A V DVI VIDEO EXTENDER DUAL LINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX SC VEL AVOMO6 SCTX VELOCITY 6 A V DVI VIDEO EXTENDER DUAL LINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTIMODE TX SC VEL AVOM06 STRX VELOCITY 6 A V DVI VIDEO EXTENDER DUAL LINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX ST VEL AVOMO6 STTX VELOCITY 6 A V DVI VIDEO EXTENDER DUAL LINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTIMODE TX ST VEL AVOMO6 NKRX VELOCITY 6 A V DVI VIDEO EXTENDER DUAL LINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX NEUTRIK VEL AVOMO6 NKTX VELOCITY 6 A V
26. AMA o 9 99 2 DVI 1 OUT DVITIN re DVI2 OUT DVIZIN ey DVI3 OUT DDC MODE DDC MODE DDC MODE ACQUIRE gs pt eo The ef trr IE HEE EE 22 0 200 ES DVI 3 OUT 1 DVI30UT2 DDC MODE DDC MODE DDC MODE ACQUIRE gt gt gt es e ih 25122 9 seror seuscr seror L4 DDC MODE DDC MODE DDC MODE GED eo MD om GD LCL REM aeni L J LCL REM FRERE LCL l L SELECT DVI I DVI 1 0UT 2 SELECT DVI 2 OUT 2 SELECT DVI Sath DVI3 OUT2 100 240V 0 5A 50 60 Hz T2A 250 VAC FIGURE 22 VELOCITY 63 Transmitter top and Receiver 3 1 DDC and EDID 3 1 1 DDC Display Data Channel and EDID Extended Display Identification Data DDC is a VESA standard transport medium between a CPU s graphics adapter and monitor The DDC is used to pass EDID Extended Display Identification Data which is stored in the monitor and describes its characteristics vendor name serial number frequency range etc With this information the CPU and video card can determine what resolutions the monito
27. Erates wena 11 2 3 Single Fiber Operation 3 2 be tese ed dece i a rdi 12 2 4 Dual Fiber Operation System 3 tc a i ra opu dax Vers ege Re 12 2 5 Fiber Operation System 6 ak a i a 12 2 6 Technical Specifications Systems 3 6 33 and 63 12 Table 1 Technical Specifications een s de i e 12 3 Connecting the DVI Extender Figures 3 22 14 3 1 DDC and EDID E 32 3 1 1 DDC Display Data Channel and EDID Extend Display Identification Data 32 3 1 2 Derault DDG i i crudi deua ur a iler Res E dpa tas 33 3 1 2 1 Remote Dynamic Mode nr 33 3 1 2 2 Remote Static Mode iii teet ed GR E aa L ok Se pde 33 341 2 9 Pass Thru Mode i A A KA A Eee 33 3 14 24 Local 18 82 o eto dean icq b e Eae adn dts 34 3 1 3 Load Default EDID is isir 34 Table 2 EDID Capability Summary A fel 34 3 1 4 DDC LEDs and Mode Button Operation a 35 OW D a A a A t d LL C AA UE 36 4 JInstallation iece e eor aed ai 37 4 1 Order of Installation Events iem al PR eet aaa l a aa a 37 5 Regulatory and Safety
28. LC June 2010 41 REVISION D thinklogical Attn RMA Insert the RMA issued to you by Thinklogical here 100 Washington Street Milford CT 06460 USA 6 2 3 Our Address If you have any issues with our products have product questions or need technical assistance with your VelocityDVI Extension System please call us at 1 203 647 8700 and let us help If shipping something with an RMA or if you d like to write us our address is Thinklogical a subsidiary of Logical Solutions Inc 100 Washington Street Milford CT 06460 USA Telephone 1 203 647 8700 June 2010 42 REVISION D thinklogical Appendix A Installation Overview A 1 VEL 3 Velocity dvi Digital Video Extender 3 Installation Overview STEP 4 Connect the supplied AC Power Adapter PWR 000022 R to the Tx and plug it into a standard AC source Power Supply PWR 000022 R DVI from CPU Velocity Digital Video Extension System 3 Transmitter DVI Local STEP 5 Connect the video source CPU to the lean Foo d RN Tx with the supplied 2 meter DVI D M M Cable CBL 000009 002 MR A L1 4VIDEO DATA Transmitter local display can also be connected using the supplied 1 meter DVI D ST SC or LC type Optical Fibers up to 1000 meters M M Cable CBL 000021 001MR L1 Data Tx to Rx amp Video L2 Data Rx to Tx STEP 3 Connect the fiber optic cables between the Rx and Tx units STEP 2 Connect the supplie
29. Line Receiver lt d ports Turn the devices ON L3 ower Connecto pper E A secondary device can be OUT and 5 Serial devices Projector Primary DDC Port June 2010 46 REVISION D A 5 VEL 33 Siaumo ennoedsoi jo Kuedoid ere Syet eoyues pue v s n UI Panase 6002 1uBu doo I NO uin pue sainos OY e 1 Jewod S 9AI929 4 y H 900000 HMd p109 Ov peijddns J98UU09 uonisod 0 440 8U ur SI YOUMS 164 2 4415 s uoul ugy SS ou d y ens eq pue sajqeo JO jou oq S19 9W 0001 01 dn sun pue x 9U u w q sajqeo odo y 1990000 6 4316 Auadoud uu s s Jeu einsu3 1 NO y uin pue 5 B gjoejda0el Jamod SJOJILISUBI L 01 H 900000 HMd DV perjddns ay 12euuo2 uonisod 0 440 u SI YMS ey 3 p 4315 5 unes pue adh eures eod uod eu 5 LNO IAG ndino 88JU y JO uoee 104 sepejdeoei NO IAG SHUN y 0 5 indino j2euuoo piepueis
30. TY 6 A N DVI VIDEO EXTENDER DUAL LINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTIMODE TX SC VEL ANOMO6 STRX VELOCITY 6 A N DVI VIDEO EXTENDER DUAL LINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX ST VEL ANOMO6 STTX VELOCITY 6 DVI VIDEO EXTENDER DUAL LINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTIMODE TX ST VEL ANOMO6 NKRX VELOCITY 6 A N DVI VIDEO EXTENDER DUAL LINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX NEUTRIK VEL ANOMO6 NKTX VELOCITY 6 A N DVI VIDEO EXTENDER DUAL LINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTIMODE TX NEUTRIK VOP M05 VELOCITY 6 OPTICS OPTION FOR TX OR RX MULTIMODE 3 FIBERS 50M OR 350M OR 1000M LC OR NEUTRIK LC VOP M02 VELOCITY 6 OPTICS OPTION FOR TX OR RX MULTIMODE 3 FIBERS 50M OR 350M OR 1000M SC OR ST 1 4 Laser Information The DVI Extender models Velocity 3 6 33 and 63 are designed and identified as Class 1 LASER products CLASS 1 LASERS do not require any special precautions under conditions of normal use June 2010 10 REVISION D thinklogical 2 Svstem Features 2 1 General Svstem Features Thinklogical s VelocityDVI Extender Systems are designed for high resolution video extension applications such as remote projection centers theaters and assembly halls and for secure computer installations The ability to remotely locate the CPU away from the monitor allows more control of your computer environment It
31. Velocitydvi Digital Video Extension System Velocitydvi 3 Velocitydvi 33 Velocitydvi 6 Velocitydvi 63 Single Link and Dual Link Fiber Extension Systems PRODUCT MANUAL Thinklogical Inc 100 Washington Street Milford Connecticut 06460 U S A Telephone 1 203 647 8700 Fax 1 203 783 9949 www thinklogical com thinklogical thinklogical thinklogical Copyright Notice Copyright O 2010 All rights reserved Printed in the U S A Thinklogical a subsidiary of Logical Solutions M Inc 100 Washington Street Milford Connecticut 06460 U S A Telephone 1 203 647 8700 All trademarks and service marks are the property of their respective owners Powered by Technology Subject VelocityDVI 3 VelocityDVI 6 VelocityDVI 33 and VelocityDVI 63 Extenders Revision D June 2010 June 2010 2 REVISION D thinklogical Table of Contents 15 41 a ag A a won ovata ala 5 18 ka Au a hdc a asa MAE aka a GA 5 1 2 Product a a D ue LL 5 Figure 1 VelocitvDVI Extenders U U emen nemen enne 6 1 3 The Models e ERO deir rei u i E IRI 7 1 4 Laser Information i eds edes 10 2 System Features i i AME 11 2 1 General System Features co uae e a E e 11 2 2 Basic OBE ABO jA A BAT MT ta TTIP 11 Figure 2 VelocityDVI Extender Overview uds
32. XTENDER SINGLELINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTIMODE TX LC VELOCITY 3 A V DVI VIDEO EXTENDER SINGLELINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX SC VELOCITY 3 A V DVI VIDEO EXTENDER SINGLELINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTIMODE TX SC 7 REVISION D thinklogical VEL AVOM03 STRX VELOCITY A V DVI VIDEO EXTENDER SINGLELINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX ST VEL AVOM03 STTX VELOCITY A V DVI VIDEO EXTENDER SINGLELINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTIMODE TX ST VEL AVOM03 NKRX VELOCITY 3 A V DVI VIDEO EXTENDER SINGLELINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO MULTI MODE RX NEUTRIK VEL AVOMO3 NKTX VELOCITY A V DVI VIDEO EXTENDER SINGLELINK DVI LOCAL DVI PORT DDC SERIAL AUDIO MULTIMODE TX NEUTRIK VOP M04 VELOCITY 3 OPTICS OPTION FOR TX OR RX MULTIMODE DUAL FIBER 50M OR 350M OR 1000M LC OR NEUTIK LC VOP M01 VELOCITY 3 AV OPTICS OPTION FOR TX OR RX MULTIMODE DUAL FIBER 50M OR 350M OR 1000M SC OR ST VEL AN0S03 SCRX VELOCITY 3 A N DVI VIDEO EXTENDER SINGLE LINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO SINGLEMODE RX SC APC VEL AN0S03 SCTX VELOCITY 3 A N DVI VIDEO EXTENDER SINGLE LINK DVI LOCAL DVI OUTPUT DDC SERIAL AUDIO SINGLEMODE TX SC APC VEL AN0S03 NKRX VELOCITY A N DVI VIDEO EXTENDER SINGLE LINK DVI AUX DVI OUTPUT DDC SERIAL AUDIO SINGLEMODE RX NEUTRIK LC VEL AN0S03 NKTX VELOCITY
33. al Velocity 6 A V TRANSMITTER DVI to Local Display DVI from CPU DDC MODE ACQUIRE MIC LINE y STATUS 2 A m LCL REM SERIAL OUT IN POWER fa 5 voc RECEIVER DVI to Display DDC to Display MIC LINE 158 s 6 STATUS U POWER 5 SERIAL IN OUT thinklogical The Future of access and Control Velocity Digital Video Extension System 6 A V Dual Link DVI Transmitter DVI from CPU IN Lower Connector Upper Connector L1 lt Video Data L2 Data L3 lt Video gt 5 a 2 a K o 2 8 2 a Powered by Technology FIGURE 15 Velocity 6 A V June 2010 26 REVISION D thinklogical Velocity 6 A V with Neutrik OpticalCon QUAD Connector TRANSMITTER STATUS e MIC LINE AN SERIAL IN RECEIVER MIC LINE SERIAL IN OUT DVI to Display DDC DVI to Display thinklogical The Future of access and Control Velocity Digital Video Extension System 6 A V with Neutrik Connector Dual Link DVI Transmitter DVI from CPU Video gt L3 Neutrik Connector Data lt L2 Video Data p L1 F DVI to Local Display Powered by Technology FIGURE 16 Velocity 6A V with Neutrik amp OpticalCon QUAD Connector June 2010 27 REVISION D thinklogical E
34. cates operation in Full Duplex When off indicates operation in Half Duplex When blinking indicates Collision FIGURE 12 Velocity 3 A N Receiver with Neutrik amp DUO Connector June 2010 23 REVISION D June 2010 thinklogical Velocity 6 DVI to Local TRANSMITTER Display DVI from CPU DDC MODE ACQUIRE G LCL REM SELECT STATUS DDC MODE ACQUIRE LCL REM SELECT STATUS 919 W e Future of access and Contro E a 0 Dife deo E 5 q deo U D olog FIGURE 13 Velocity 6 Dual Link DVI 24 REVISION D thinklogical Velocitv 6 with Neutrik transmitter OpticalCon QUAD Connector x DDC MODE ACQUIRE 5 o PIT LCL REM SELECT STATUS POWER 5 NE RECEIVER DVI to Local Display DVI from CPU DDC L3 O Oj L1 DDC MODE E GREED SELECT AC Q STATUS e POWER 4 5 amp DVI to Display DDC DVI to Display 919 WW e of acce and Contro 0 O m O ecto deo U a e 5 BI IC deo O Co a FIGURE 14 Velocity 6 with Neutrik OpticalCon QUAD Connector June 2010 25 REVISION D thinklogic
35. d AC Power Adapter PWR 000022 R to the Rx and plug it into a standard AC source Local Monitor Power Supply PWR 000022 R DVI to Display Digital Video Extension System 3 Receiver DVI to Display L2 DATA L1 P gt VIDEO DATA Powered by Technology Receiver Projector STEP 1 Connect the Rx Primary Port to a projector Primary DDC Port video monitor or other viewing device with a DVI D li M M Cable A second device can be installed using June 2010 43 REVISION D a similar cable Turn on the DVI video devices thinklogical A 2 VEL 3 A V 5 Velocitydvi Digital Video Extender 3 A V Installation Overview STEP 4 Connect the supplied AC Power Adapter PWR 000022 R to the Tx and plug it into a standard AC source Power Supply PWR 000022 R i a lt Line IN thinklogical e Mic OUT gt Serial Port E Velocity Digital Video Extension System 3 A V Transmitter STEP 5 Connect the video source CPU to the Tx with the supplied 2 meter DVI D M M bs ER Cable CBL 000009 002MR A IRTS Technology local display can also be connected to the TX using the supplied 1 meter DVI D M M 4 cable 000021 001 Monitor Connect the Line IN Mic OUT and Serial Ports from the CPU to ST SC or LC type Optical Fibers up to 1000 meters the Tx using the two supplied L1 Data Tx to Rx
36. d to initiate DDC collection This button works with all modes except Pass Thru e Select Button The lower button is used to select the DDC Mode of operation The modes will cycle through Remote Dynamic Remote Static PassThru and Local Static e Both Buttons Held 5 seconds Holding both buttons for 5 seconds will reload the default DDC table into the TX and switch to Remote Static mode e Local and Remote LED Mode Indication LCL REM DDC MODE DESCRIPTION CN EDID READ FROM REMOTE DISPLAY e 1 AND UPDATED EACH TIME REMOTE GREEN DISPLAY CHANGES ORANGE GREEN STATIC WHEN ACQUIRE BUTTON IS PRESSED e e ACTS AS A DIRECT CONNECTION PASS THRU BETWEEN CPU AND DISPLAY NO GREEN GREEN EMULATION IS PERFORMED LOCAL EDID READ FROM LOCAL DISPLAY GREEN ORANGE STATIC WHEN ACQUIRE BUTTON IS PRESSED June 2010 35 REVISION D thinklogical e T STATUS L1 L2 1586 e TX Status LED The status LED indicates the connection status of the TX Extender Green Fiber L2 is connected and a good link is established Orange Local Static Mode selected and no fiber link from RX to TX L2 is not connected or both buttons are held down and the unit is waiting to reload the default DDC table Red Flashing No Fiber Link from RX to TX Not available in Local Static mode For Vel 6 models there is no LED indication for Fiber L3 In single link mode video is not affected if L3 is not connected In dual link mode there will b
37. e no video if L3 is not connected e RX Status LED The status LED indicates the connection status of the RX Extender Green Good Link and DVI monitor connected to primary port port on left looking at DVI connectors Orange No monitor connected to primary port Red Flashing No Fiber Link from TX to RX L1 is not connected e Power LED When lit the Green LED near the power jack indicates that 5VDC power is applied to the unit e Grounding Stud A grounding stud located below the power jack allows the unit to be hard wired to electrical ground if required 3 2 AC Power Vel 3 and Vel 6 Two wall pack AC DC adapters PN PWR 000022 R are included with the Vel 3 and Vel 6 models The AC wall pack has a universal power rating 100 240 VAC 50 60Hz and also has interchangeable wall plug adapters for various AC power receptacles found throughout the world shown below Use the appropriate plug for your country or location 5VDC Continuous Short Circuit Protection Y Over Voltage Protection Conductive EMI Meets CISPR FCC Class B high efficiency 75 Typical t June 2010 36 REVISION D thinklogical 4 Installation 4 1 Order of Installation Events If you intend to mount your VelocityDVI 3 or 6 Extenders instructions are included in Appendix B on page 49 It is recommended that you securely mount the unit s before installing the cabling and power sources See Appendix A Installation Overview
38. hnology Technology VEL 6 Transmitter VEL 6 Receiver Velocitydvi Digital Video Extender 6 thinklogical Velocityc vi STATUS Digital Video Extension System 33 Tran STATUS Velocitydvi Digital Video Extender 33 L STATUS STATUS Velocitydvi Digital Video Ext STATUS tension System 63 Velocitvdvi Digital Video Extender 63 FIGURE 1 Ve ocitvDVI Extenders June 2010 6 REVISION D 1 3 VEL 000S03 SCRX VEL 000S03 SCTX VOP S05 VEL 000S06 SCRX VEL 000S06 SCTX VOP S08 thinklogical The Models VELOCITY 3 DVI VIDEO EXTENDER SINGLE LINK DVI AUX DVI OUTPUT DDC SINGLEMODE SC APC VELOCITY 3 DVI VIDEO EXTENDER SINGLE LINK DVI LOCAL DVI OUTPUT DDC SINGLEMODE SC APC VELOCITY 3 OPTICS OPTION FOR TX OR RX SINGLEMODE DUAL FIBERS 10KM VELOCITY 6 DVI VIDEO EXTENDER DUAL LINK DVI AUX DUAL DVI OUTPUT DDC SINGLEMODE SC APC VELOCITY 6 DVI VIDEO EXTENDER DUAL LINK DVI LOCAL DUAL DVI OUTPUT DDC SINGLEMODE SC APC VELOCITY 6 OPTICS OPTION FOR TX OR RX SINGLEMODE 3 FIBERS 10KM VEL 000M03 LCRX VELOCITY 3 SINGLE LINK DVI DDC MULTIMODE RX LC VEL 000M03 LCTX VELOCITY 3 SINGLE LINK DVI DDC MULTIMODE TX LC VEL 000M03 SCRX VELOCITY 3 SINGLE LINK DVI DDC MULTIMODE RX SC VEL 000M03 SCTX VELOCITY 3 SINGLE LINK DVI DDC MULTIMODE TX SC VEL 000M03 STRX VELOCITY 3 SINGLE LINK DVI DDC MULTIMODE RX ST VEL 000M03 STTX
39. igital Video Extension System 3 itte DIMENSIONS inches 5 375 W x 7 0 D x 1 1 H m Local DVI froi 3 inches minimum eorbOpj rijj Display DDC CPU T mu T o 2 5 3 DVI from Display DDC CPU u DIMENSIONS metric 136 65mm x 177 80mm x 27 94mm 5 5 W 10 0 D x 1 1 H 139 70mm x 254 00mm x 27 94mm 5 375 W x 7 0 D x 2 0 H 136 65mm x 177 80mm x 50 80mm 7 5 W x 7 0 D x 1 1 H 190 50mm x 177 80mm x 27 94mm 7 5 W x 10 0 D x 1 1 H 190 50mm x 254 00mm x 27 94mm 7 5 W x 7 0 D x 2 0 H 190 50mm x 177 80mm x 50 80mm 7 5 W x 7 0 D x 1 1 H 190 50mm x 254 00mm x 27 94mm 7 5 W x 7 0 D x 2 0 H 190 50mm x 177 80mm x 50 80mm 5 5 W x 7 75 D x 1 1 H 139 70mm 196 85mm 27 94mm 5 375 W x 7 0 D x 2 44 H 136 65mm 177 80mm 61 98mm 7 5 W x 7 75 D x 1 1 H 190 50mm x 196 85mm 27 94mm 7 5 W x 7 0 D x 2 44 H 190 50mm x 177 80mm x 61 98mm 7 5 W x 7 75 D x 1 1 H 190 50mm x 196 85mm x 27 94mm 7 5 W x 7 75 D x 2 0 H 190 50mm x 196 85mm x 50 80mm 19 0 W x 10 0 D x 1 72 H 482 60mm x 254 00mm x 43 69mm 19 0 W x 7 84 D x 1 72 H 482 60mm x 199 14mm x 43 69mm 49 REVISION D thinklogical Appendix C RJ 45 Adapter Pin outs Tx Rx Velocity 3 6 A V and Tx Velocity 3 6 A V and A N Rx ADP 000025 R DB9 Female ADP 000019 R DB9 Ma
40. lTanty i E DU D a 41 6 2 2 Return Merchandise Authorization 41 6 2 3 UE 5 GS ntt one iati eel et Leere 42 Appendix A Installation Overview u ananasas anas saaa 43 ASA zc pL 43 AQ VEL S AW dc peste Ando L a aq ca GEM ELI aS d Ub I die 44 VEL cnr 45 A V cce RT 46 AS MEL BB outside a asun i i a ten a 47 A6 VEL add a a ii a a a a a a a a a end ata 48 Appendix B DVI Extender U J Q 49 Appendix C RJ45 Adapter Pin outs esee eene eene eene nenne 50 June 2010 4 REVISION D thinklogical 1 Introduction 1 1 Contents When you receive your Thinklogical VelocityDVI Extension System you should find the following items DVI Extender Transmitter DVI Extender Receiver DVI D Male to Male Cable 2 Meter CBL 000009 002MR DVI D Male to Male Dual Link Cable 2 Meters CBL 000023 002MR Universal AC Power Adapters PWR 000022 R Quantity 2 Vel 3 6 AC Power Cord PWR 000006 R Quantity 2 Vel 33 63 CAT5 Cable Assembly CBL000001 002MR 3 5mm Audio Cable Quantity 2 000016 006 DB9F Adapter ADP 000025 R and DB9M Adapter ADP 000019 R CD Product Manual For VelocityDVI 3 Qty 1 each For VelocityDVI 33 Qty 3 each 2 For VelocityDVI 6 Qty 1 each For VelocityDVI 63 Q
41. le RJ 45 RJ 45 1 RTS 1 DTR 2 x 5 Signal Ground ADP 000019 R DB9 Male June 2010 50 REVISION D
42. oduct may cause radio interference in which case the user may be required to take corrective measures 5 2 3 European Union 5 2 3 1 Declaration of Conformity Product name VelocityDVI Digital Video Extension System 3 VelocityDVI Digital Video Extension System 6 VelocityDVI Digital Video Extension System 33 VelocityDVI Digital Video Extension System 63 These products comply with the requirements of Low Voltage Directive 72 23 EEC and EMC Directive 89 336 EEC 5 2 3 2 Standards With Which Our Products Comply Safety CENELEC EN 60950 1 1 Edition 2001 Laser Safety IEC60825 2001 Parts 1 and 2 Class 1 Laser Product Electromagnetic Emissions EN55022 1994 IEC CSPIR22 1993 EN61000 3 2 A1 4 2000 EN61000 3 3 1994 Electromagnetic Immunity EN55024 1998 Information Technology Equipment Immunity Characteristics EN61000 4 2 1995 Electro Static Discharge Test EN61000 4 3 1996 Radiated Immunity Field Test EN61000 4 4 1995 Electrical Fast Transient Test EN61000 4 5 1995 Power Supply Surge Test EN61000 4 6 1996 Conducted Immunity Test EN61000 4 8 1993 Magnetic Field Test EN61000 4 11 1994 Voltage Dips amp Interrupts Test June 2010 38 REVISION D thinklogical 5 2 4 Supplementary Information The following statements may be appropriate for certain geographical regions but might not apply to your location NOTE This equipment has been tested and found to comply with the limits for a
43. ors Refer to the Installation Overviews included in Appendix A B amp C on pages 43 through 50 Velocity 3 Short Body DVI to Local TRANSMITTER Display DVI from CPU N O il STATUS ACQUIRES to E PEN LCL REM C SELECT 223 RECEIVER N N u STATUS ACQUIRE co bun Ad gt PA LCL REM ig Tu 897961 GLES 617111 616 7 00 177 80mm Physical dimensions are the same for both the Transmitter and Receiver chassis FIGURE 3 VELOCITY 3 Short Body June 2010 14 REVISION D thinklogical Velocity 3 Long Body TRANSMITTER DVI from CPU DVI Local Display STATUS STATUS LCL REM SELECT ere WW e ol access And One FIGURE 4 VELOCITY 3 Long Body June 2010 15 REVISION D thinklogical Velocity 3 with Neutrik Connector TRANSMITTER DDC MODE ACQUIRE 4 d nca STATUS 0 4 s e 5VDC DVI to Local Display RECEIVER DDC ee LCL REM seteer DVI from CPU DDC MODE ACQUIRE ee LCL REM SELECT DVI to Display DDC DVI to Display FIGURE 5 VELOCITY 3 with Neutrik amp OpticalCon DUO Connector June 2010 16 REVISION D
44. r Adapter PWR 000022 R to the Tx and plug it into a standard AC source Power Supply PWR 000022 R a lt Line IN 910 Mic OUT gt Serial Port 45 STEP 5 Connect the video ju source CPU to the Tx with the mm supplied 2 meter DVI D M M B similar cable Connect the Line IN Mic OUT and Serial Ports L1 Data Tx to Rx amp Video Primary L2 Data Rx to Tx Dual Link Cable CBL 000023 002MR A local display can also i Transmitter Local Monitor from the CPU to the Tx using the ST SC or LC type Optical Fibers up to 1000 meters two supplied 2 5mm Audio cables and the RJ45 CAT5 cable L3 Video Secondary STEP 3 Connect the fiber optic cables between the Rx and Tx units STEP 2 Connect the supplied AC Power Adapter PWR 000022 R to the Rx and plug it into a standard AC source Power Supply PWR 000022 R Line OUT Serial Port External Lighting sensors etc 23 SE 2 l ilu STEP 1 Connect the eco Rx Primary Port to a projector video monitor or 8 other viewing device with a He pata 5 installed using a similar cable TUA deo Data Po air oaa to the appropriate Receiver a pe DVI D M M Dual Link Cable Connect your Mic IN
45. r is capable of The DDC bus can be unidirectional or bidirectional A bidirectional bus supports content protection HDCP and display calibration software High bandwidth Digital Content Protection is a specification used to encrypt and protect digital video and audio signals transmitted between two HDCP enabled devices A NOTE Most DVI D graphics adapters will not boot if a valid EDID table is not received at power up June 2010 32 REVISION D thinklogical 3 1 2 Default DDC Modes 3 1 2 1 Remote Dvnamic Mode Svstem 3 2 fibers required Svstem 6 3 fibers required The unit acts as a direct connection between the RX and TX In this mode DDC data is read at the RX and sent to the TX Once verified at the TX the information is written into a PROM on the TX and provided to the CPU video card The RX will not send DDC data to the TX unless a different display is connected to the RX Advantages Allows CPU video card to boot when there is no fiber connection to the RX Limitations No communication link from the CPU to the display Prevents the use of HDCP or monitor configuration color tuning When switching between DDC modes except Pass Thru you will need to press the Acquire button to activate the new mode 3 1 2 2 Remote Static Mode Sys 3 2 fibers required to acquire DDC data 1 fiber thereafter Sys 6 3 fibers required to acquire DDC data 2 fibers thereafter Remote Static Mode is a subset of Dynamic Mode in
46. s warranty set forth above to the fullest extent permitted under applicable law Thinklogical LLC and its suppliers disclaim any and all other warranties express and implied including without limitation the implied warranties of merchantability fitness for a particular purpose title and non infringement If the defective product is returned to the authorized dealer within one 1 year of the delivery date repair or replacement of the product will be made Repairs may be made with refurbished parts If repair or replacement is not possible Thinklogical may keep the defective product and refund the amount that you paid for the defective product These are Thinklogical s sole obligations and your exclusive remedies for a breach of the limited warranty set forth above To return a defective product contact the Thinklogical authorized dealer from whom you purchased the product Do not return a product directly to Thinklogical without prior authorization from your dealer If you have received prior authorization from your dealer and are returning a product directly to Thinklogical 1 Contact your sales representative or call Customer Support at 800 291 321 1 203 647 8700 2 Describe the defect with the product and Customer Support will issue a Return Merchandise Authorization Number RMA 3 Pack the product in all of its original packing if possible and write the RMA number on the box 4 Return the product to Thinklogical L
47. ses for your various needs Info thinkloqical com Information about Thinklogical and our products sales thinklogical com Sales Department orders or questions support thinklogical com Product support technical issues or questions product repairs and request for Return Authorization 6 1 3 Telephone Telephone Sales Contact our expert sales staff via telephone in Milford CT at 1 203 647 8700 or if in the continental US you may use our toll free number 1 800 291 3211 We are here Monday through Friday from 8 30am to 5 30pm Eastern Time Zone Be sure to ask for your sales representative s direct dial phone number when you call Telephone Product Support Please contact our expert Product Support staff via telephone in Milford Connecticut at 1 203 647 8700 The support lines are manned Monday through Friday 8 30am to 5 30pm Eastern Time Zone June 2010 40 REVISION D thinklogical International Sales Please contact our US Sales Staff in Milford Connecticut at 1 203 647 8700 We are here Monday through Friday 8 30am to 5 30pm Eastern Time Zone same as New York City If leaving a voice message please provide a preferred time to call back so we may reach you at your convenience Our switchboard attendant will direct your call during regular business hours We have an automated attendant answering our main telephone switchboard after regular business hours and on holidays You may leave a voice message for any
48. ters 1 each Vel 3 3 each Vel 33 CBL000023 002MR Dual link DVI D Male to 2 meters 1 each Vel 6 each Vel 63 Approvals for US Canada and European Union 12 months from date of shipment Extended warranties available at time of purchase DIMENSIONS inches 5 375 W x 7 0 D x 1 1 H DIMENSIONS metric 136 65mm x 177 80mm x 27 94mm 5 5 W 10 0 D x 1 1 H 139 70mm x 254 00mm x 27 94mm 5 375 W x 7 0 D x 2 0 H 136 65mm x 177 80mm x 50 80mm 7 5 W x 7 0 D x 1 1 H 190 50mm x 177 80mm x 27 94mm 7 5 W x 10 0 D x 1 1 H 190 50mm x 254 00mm x 27 94mm 7 5 W x 7 0 D x 2 0 H 190 50mm x 177 80mm x 50 80mm 7 5 W x 7 0 D x 1 1 H 190 50mm x 254 00mm x 27 94mm 7 5 W x 7 0 D x 2 0 H 190 50mm x 177 80mm x 50 80mm 5 5 W x 7 75 D x 1 1 H 139 70mm x 196 85mm x 27 94mm 5 375 W x 7 0 D x 2 44 H 136 65mm x 177 80mm x 61 98mm 7 5 W x 7 75 D x 1 1 H 190 50mm x 196 85mm x 27 94mm 7 5 W x 7 0 D x 2 44 190 50mm x 177 80mm x 61 98mm 7 5 W x 7 75 D x 1 1 H 190 50mm x 196 85mm x 27 94mm 7 5 W x 7 75 D x 2 0 H 190 50mm x 196 85mm x 50 80mm 19 0 W x 10 0 D x 1 72 H 482 60mm x 254 00mm x 43 69mm 19 0 W x 7 84 D x 1 72 H 482 60mm x 199 14mm x 43 69mm TABLE 1 Technical Specifications 13 REVISION D thinklogical 3 Connecting the DVI Extender All physical connections to these products use industry standard connect
49. that once a transfer from the RX to the TX is completed successfully no other transfer will be made unless specifically requested by using the Acquire Button The DDC data stored in the TX PROM will not change regardless of display changes Advantages Allows the user to acquire and use an EDID table regardless of changes in connection at the RX Limitations No communication link from the CPU to the display Prevents the use of HDCP or monitor configuration color tuning May result in no video if a display with lower resolution capability is subsequently connected 3 1 2 3 Pass Thru Mode Sys 3 2 fibers required Sys 6 3 fibers required The units act as a direct connection between the TX and RX This mode allows the CPU to communicate directly with the monitor Advantages Allows monitor color tuning and HDCP Limitations If a monitor is not connected to the RX most video cards will not boot June 2010 33 REVISION D thinklogical 3 1 2 4 Local Static Mode Sys 3 1 fiber required Sys 6 2 fibers required Local Static mode operates in the same manner as Remote Static mode except that the EDID table is read from a monitor plugged into the local port of the TX Once the Acquire button is pressed the TX will begin reading the DDC from the locally connected monitor until a valid EDID table is read The table will then be stored on the TX and presented to the CPU Advantages The TX does not need to be connected to the video card or RX
50. ts for the year and two or three digits for a unique unit number This serial number is also found on the original shipping carton June 2010 39 REVISION D thinklogical 6 How to Contact Us 6 1 Customer Support Thank you for choosing Thinklogical products for your application We appreciate your business and are dedicated to helping you successfully use our products Thinklogical is always here to help you To contact us please use the following telephone numbers and internet based methods 6 1 1 Website Visit our website for more product information current updates and the full line of Thinklogical products Internet www thinklogical com Our internet website offers product information on all current systems including technical specification sheets and Quick Start Guides for viewing online or for download product diagrams showing physical connections and other information you might need We are continually updating our website so be sure to update your browser when visiting the Thinklogical website to see our most up to date information A NOTE Most online documents are stored as Adobe Acrobat PDF files If you do not have the Adobe Acrobat reader needed to view PDF files visit www adobe com for a download 6 1 2 Email Thinklogical is staffed Monday through Friday from 8 30am to 5 30pm Eastern Time Zone We will try to respond to your email inquiries promptly Please use the following email addres
51. ty 3 each With A V and A N models With A V models only 1 2 Product Overview MRTS Technology 6 25 Gbps allows for Full Frame Rate Transmission of uncompressed DVI Powered by Thinklogical s cutting edge patent pending MRTS Multi Rate Transmission System Technology our DVI extension systems transport every frame of a DVI video stream seamlessly with no compression or dropped frames In addition all high speed peripherals function with no latency Leveraging standard SFP transceivers the system uses multi mode fiber optic cable to permit the placement of a digital monitor or projector up to 1000 meters 3280 feet away from the controlling computer without loss of resolution Installation is plug and play and no adjustments are necessary Each Vel 3 single link and Vel 6 dual link system consists of one transmitter per chassis and one receiver per chassis The rack mountable Vel 33 system single link and the rack mountable Vel 63 system dual link each feature three transmitters per chassis and three receivers per chassis All models support Data Display Channel DDC with a variety of modes to meet each unique requirement All models are connected by multi mode fiber optic cable s the count of which varies depending upon the DDC mode to provide communications to and from the transmitter The transmitter unit connects to the CPU with supplied DVI D cables and audio serial amp network cables in A V and A N models