1. 1 Back Panel Check back panel that corresponds to model you have chosen frat Rincon RS232 Port This ensures that the UPS can be monitored using a computer software This is used to protect UPS against overload and short circuit Input Socket This is the socket for mains connection Output Sockets These are the sockets for load connections These are used for cooling the UPS Contact Cover This is used to prevent the contact with live contacts External Battery This is wh bl d 7 Cabin Contacts on This is where cable connections are made th cabin if optional external battery cabin is used Table 2 1 Back Panel Operation Page 8 L2 2 3kVA v1 0 1 2 3 Connection for the model with connection terminal o 00 BAT BAT TIN IN F R Na No Connection Terminal BAT EB O BAT BATTERY External Battery pole Cabin a U OUTN2 2 Table 2 2 Connection Terminal Operation OUT OUT E1 u N2 E2 2 4 Communication with PC You can monitor the UPS over RS232 port using UPSilon2000 software that you will install on your computer this is optional and therefore UPS software and RS232 cable must be ordered prior to use of this option Using this software you can monitor real time UPS voltage and current information battery information malfunctioning warnings etc and save long term logs with graphics In addition software shuts down your computer and
2. Table of Contents NVEFOGUICTIONN descrita aut 2 Important Safety Information Be Sure to Read cccecessesseeeeeeeeseeeeeeees 3 Ta OMC Wo a aa aE a 5 A E E A E E EE a ele E A 5 AFONRERE a AT E 6 Zs WAST ANAC ONY ela 7 2 ace Me ta 7 22 BACK PAM al caras 8 2 3 Connection for the model with connection terminal oo oocionnom 9 ZA COMMUN AUIS WII PE eh a shaw alg i a gel Lae os das a als 9 9 Operator ia 10 SA A A 10 OZ SWITCHING Ostia id 12 SS Operan MOLES a ai 13 AO CAOS a o it e 14 3 5 Automatic Battery Test ooccococccconconnonoconoonoconconoonocononnonconancanonnnno 15 E A O ON 15 AUDE Vanidad dt da tdt tala 15 3 0 SOLUIMOGS MEMU seccatid dd dida ide 16 4 WF OUDICSIOOUING oi kes nee pence in ecaicanue Seve vise etnaesuerrceeienaccaesinesveaicevisesnmeeeneesanes 18 de Mamntena nte ieee a a AS 19 6 Technical SPecifiCatONS ia dd da cid 20 L2 2 3kVA v1 0 1 Page 1 Introduction Thank you for choosing our Uninterruptible Power Supply product for protection of your electrical devices The L2 Series Uninterruptible Power Supply UPS was manufactured using the latest technology We recommend you to read this manual to learn many specifications and superior features of your new UPS We do pay attention to the environmental impacts of this product Example of some of our measures to protect environment are as follows Y Product design is based on economical size and high efficiency approac
3. ains connection Press ON button until an audible warning is heard meanwhile observe that NORMAL LED is turned on Figure 3 7 Along with audible warning all LED lights will flash and UPS will start up Observe that battery indicators LED lights are on and press ON button briefly Figure 3 8 Figure 3 7 Figure 3 8 b Following 2 consecutive audible warnings INVERTER LED will turn on Figure 3 9 At this stage you can connect your loads to output sockets for models with patch cable Figure 3 10 or turn on your loads connected to UPS output for models with contact AD 02 TTERY ane INVERTER MM __ _ _ NORMAL x BS TEMP HIGH CURR FAULT Ey E e gt ag The UPS will also start up on battery in cases where although a mains connection Is available mains voltage and or mains frequency is out of tolerance limits L2 2 3kVA V1 0 1 Page 11 3 2 Switching Off 1 If UPS is in Normal Operation Mode Turn off your loads safely Briefly press OFF button Figure 3 11 and observe that NORMAL LED turns off Press and hold OFF button until audible warning silences Figure 3 12 and observe that el indicator LED lights turn su ro o o o aa NO INVERTER LOAD ntti NORMAL INVERTER Figure 3 11 Figure 3 12 Before fully switching off the UPS operating in normal mode switch off the output by briefly pressing OFF button A When disconnecting cable connection of models with patch cable
4. ation modes Transfer AVR Switch Filter Mains Output Charger Battery Inverter Figure 3 16 Mains Interactive UPS Operation Principle Normal Mode Mains voltage is fed through filter and Automatic Voltage Regulation AVR units and transferred to output via transfer switch Meanwhile battery charger unit charges batteries with voltage supplied from input unit Battery Mode Battery charger and Automatic Voltage Regulation AVR units does not operate Inverter unit generates appropriate voltage by discharging battery power Generated voltage is transferred to output via output switch Sleep Mode This operation mode ensures that battery capacity is used efficiently and battery life is maintained UPS operates on Sleep mode in following cases a When the UPS is connected to mains it begins operating in Sleep mode Batteries are charged even if the UPS is not switched on b When the load percentage is less than 5 during battery mode the UPS will switch off the output and switch to Sleep mode Output switch off when load percentage is less than 5 during battery operation can be cancelled See 3 8 Settings L2 2 3kVA V1 0 1 Page 13 c When the battery capacity is 0 the UPS will switch off the output and switch to Sleep mode Once mains voltage and mains frequency are within the tolerance limits again UPS will begin running in normal mode automatically 3 4 Indicators Battery Indicator Rema
5. epth mm eee 175 x 265 x 485 T Backup Time Net Weight kg min UPS Cabin External Battery 100 load 50 Cabin load 2KVA 3KVA 15 9 17 9 o o an IS 176 TESIS Table 1 2 External Battery Cabin Dimensions and Weights Figure 1 2 External Battery Cabin L2 2 3kVA V1 0 1 Page 5 1 2 Front Panel 7 4 10 Y l DA iil _ E OVER LOAD 00 BATTERY GE HIGH 100 i y N INVERTER 00000 CA O GG Norma N A OVER BATT OVER OUTPUT 100 h TEMP HIGH CURR FAULT y 4 N FAULT A ES Low N Figure 1 3 Front Panel No INDICATOR Explanation Ea BATTERY This shows the remaining battery life in percentage This shows the percentage of power utilized by loads LOAD connected to output in comparison to total UPS output Capacity fe ae ene a EN OVERLOAD See 3 6 Overload 3 6 Overload UPS is loaded UPS is loaded 0 to 100 to 100 INVERTER a is operating on UPS is not operating on battery battery See 3 7 Audible ES FAULT Warnings No malfunction or warning Mains Voitageis al gasi Mains voltage is within the LOW 10 lower than normal age tolerance limits voltage NORMAL Mains voltage is within Mains voltage is out of the tolerance limits tolerance limits Mans Valea Is Ar gast Mains voltage is within the 10 greater than normal eee tolerance limits voltage gt 3 seconds lt 3 seconds BUTTON Press and hold longer Press less than 3 than 3 second
6. eries Battery poses electric shock hazard and short circuit risks Replace only with batteries of same type capacity number and dimensions Battery replacement must be carried out by trained service personnel only Remove metal accessories such as wristwatch ring etc and wear rubber shoes and gloves to prevent accidents and personal injury Use tools with isolated handles Make sure that battery connections are not grounded by mistake Do not leave tools or metal pieces on batteries Batteries must be recycled Return mutilated batteries to any recycling facility or to company where you initially purchased them along with packaging material of new batteries UPS must be installed in strict adherence to following standards v HD 384 4 42 S1 Electrical Installation in Buildings Chapter 4 Safety Protection Group 42 Protection Against Thermal Effects v HD 384 4 482 S1 Electrical Installation in Buildings Chapter 4 Safety Protection Group 48 Choosing Protective Measures Against External Effects Section 482 Fire Protection in Places Bearing Special Risks or Dangers Page 4 L2 2 3kVAV1 0 1 1 Overview 1 1 L2 Series UPS Cabin UPS Power WIVA Width x Height x Depth mm 1400 2000 175 x 265 x 485 2100 3000 Backup Time Net Weight kg min 100 load 50 Figure 1 1 UPS Cabin Table 1 1 UPS Cabin Dimensions and Weights External Battery Cabin optional Width x Height x D
7. h Y Quality and uninterruptible power is provided without distorting source voltage Y Manufacturing is carried out in our ISO 14001 2004 Environment Management System certified factory v It is ensured that battery and metal wastes are disposed properly To discover the entire range of our products and to receive up to date information please visit our web site Before you call us If you require assistance for a failure or any related issues call our Technical Support Center For quick assistance please have the following information available Model L2 Series Power KVA heen ace teeeeeeenneneeeeneeenaeneeeen Serial Number aananannunnnnunnnunnunnnnnnnnnnnnnne Purchase Date gt ha uucuuuuuuuucuuuunuuueuuuuueuueeeas Installation Date ha cccueuucccuccuucnuuuuueuueeueeuaas Mains Voltage Frequency _ cccceeeeseeeeeeneeenseneeees Battery Quantity x AN nassssssssssnnnnnnnnnnnnnnnnnnennnne Company cc rr rr The L2 Series products are protected under a patent Therefore implementation of our proprietary technology by competitors is not permitted Given the relevant standards and technology device hardware configuration may be changed without notice Technical specifications and dimension information are not binding unless formally confirmed by us Page 2 L2 2 3kVAV1 0 1 Important Safety Information Be Sure To Read Life Safety Use UPS in an access restricted room EN 62040 1 2 The UPS has its o
8. ies are malfunctioned Table 4 1 Troubleshooting Table Contact the Technical Service Figure 4 1 See the one that corresponds to model you have chosen Page 18 12 2 3kVAV1 0 1 5 Maintenance The UPS should only be opened by authorized personnel The UPS must be completely off during maintenance Mains and battery connections must be disconnected and batteries must be moved away from the UPS Follow the Important Safety Information and Installation instructions during the maintenance The electronic boards and the fans should be cleaned regularly The ventilation holes on the lid should be cleaned regularly The UPS body should be cleaned with a soft and moist cloth The sturdiness of cable connections screws and sockets should be checked The board supply voltages should be measured and checked The components on the boards and the other hardware should be checked The voltages of the batteries should be checked by measuring the voltages separately The accuracy of the calibration and the adjustments should be checked The dust the heat and the temperature in the UPS room should be checked The instructions in the Important Safety Information and Installation should be complied D D D D D D 0 L2 2 3kVA V1 0 1 Page 19 6 Technical Specifications Power KVA Voltage Voltage tolerances Frequenc Frequency tolerances Voltage Voltage tolerances Frequenc F
9. in overly humid environments Never allow water or foreign substances to penetrate in the UPS Strictly do not clog ventilation grids of the UPS Never expose the UPS to direct sunlight or a direct heat source The UPS usetul life is 10 years L2 2 3kVA V1 0 1 Page 3 Special Safety Information UPS electrical connections must be provided as shown in the manual Be sure to check the compatibility of the UPS power to mains voltage and to total load that will be supplied with UPS UPS must be stored in a dry environment between 10 C and 45 C temperature prior to commissioning UPS must be operated at least once a month continuously for 24 hours to charge the batteries Because the battery life commences on the manufacture date storage life is limited UPS is designed to operate at height operating environment temperature relative humidity rate and handling and storage conditions described in UPS manual Special design and protection measures are essential for non normal operating conditions Such non normal operating conditions include Harmful fume dust abrasive dust Humidity vapor bad weather frost Explosive dust and gas mixtures Extreme temperature changes Poor ventilation Exposure to direct or radiated temperature from other sources Intensive electromagnetic fields and harmful radioactive levels Insects pests fungus etc Change and Recycling of Batt
10. ining Battery Capacity LED Display Between 0 and 25 a 100 Between 26 and 50 ee TT JE 100 Between 51 and 75 ae Y JE 100 Between 76 and 90 JE 100 More than 91 BATTERY E A C 100 Figure 3 1 Battery Indicator Table Load Indicator Loading Ratio LED Display Between 0 and 9 A OVER BATT OVER OUTPUT 100 TEMP HIGH CURR FAULT Between 10 and 25 meets OVER BATT OVER OUTPUT 100 TEMP HIGH CURR FAULT Between 26 and 50 a a oe OVER BATT OVER OUTPUT 100 TEMP HIGH CURR FAULT Between 51 and 75 a T OVER BATT OVER OUTPUT 100 TEMP HIGH CURR FAULT Between 76 and 95 OVER BATT OVER OUTPUT 100 TEMP HIGH CURR FAULT More than 96 LOAD a A ME gt OVER BATT OVER OUTPUT 100 TEMP HIGH CURR FAULT Figure 3 2 Load Indicator Table Page 14 12 2 3kVAV1 0 1 Battery indicator s 0 25 LED and capacity used indicator s more than 96 LED are red and indicate that the device is at dangerous apeiaton limits 3 5 Automatic Battery Test The UPS self diagnoses the batteries by running on battery automatically at every 30 days The testing process is run when UPS is in normal operation mode At the end of the test the condition of the batteries usable or not is provided When the Battery Test is negative please contact with the Technical Service The Automatic Battery Test may also be run after long power FS Outages In thi
11. nical Service A Cable connections and fuse checks must be performed by authorized personnel only o Possible Failure Solution ON button is pressed too Press and hold ON button for at least 3 shortly seconds Batteries run out fully UPS must be connected to mains UPS is not turned on Mains voltage and or Mains voltage and frequency must be and the lights are not frequency is out of limits checked lit Press the fuse inwards Figure 4 1 Problem with patch cord Battery connections must be checked connections Contact the Technical Service Mains voltage and or Mains voltage and frequency must be frequency is out of limits checked UPS operates on Fuse blown Press the fuse inwards Figure 4 1 battery constantly Problem with mains o mle beredd connection Contact the Technical Service J Battery Failure warning See 3 5 Automatic Battery Test Check UPS loading ratio and Error LED is on and Overheat warning environment temperature Switch off UPS is constantly UPS and wait for a while emitting audible Over current warning aii Output Fault warning Battery High warning Overload LED is on and UPS is veto warih Check loading ratio Reduce loads constantly emitting g connected to UPS output audible warning Batteries are not fully Try again once batteries are charged for Battery operation charged at least 8 hours time is too short Battery charger or batter
12. or server safely in case of any electrical power outage Or RS232 o ie ee 103 6121918 UPB Cormrkd 100 SS Eisen rl mae al 100000 Figure 2 3 RS232 Communication L2 2 3kVA V1 0 1 Page 9 3 Operation 3 1 Switching On 1 Switching on mains voltage a For models with patch cable Firstly plug in the patch cable to mains socket Figure 3 1 later plug it in to input socket Figure 3 2 For models with terminals Make sure that cable connections were provided appropriately Figure 3 1 Figure 3 2 b Press ON button until an audible warning is heard meanwhile observe that NORMAL LED is turned on Figure 3 3 Along with audible warning all LED lights flash and UPS starts up Observe that battery indicator LED lights are on and briefly press ON button Figure 3 4 3 T ieee OVER LOAD BATTERY HIGH OVER LOAD N 100 y N Figure 3 3 Figure 3 4 c If mains voltage and mains frequency are within the limits NORMAL LED will be on constantly Figure 3 5 if they are out of limits NORMAL LED will not turn on See Starting on Battery At this stage you can connect your loads to output sockets for models with patch cable Figure 3 6 or turn on your loads connected to UPS output for models with contact Figure 3 5 Figure 3 6 Page 10 12 2 3kVAV1 0 1 2 Cold Start a The UPS has Cold Start feature It means that the UPS can be started on battery without m
13. remove input socket first and later the mains socket Figure 3 13 2 eo A A Figure 3 13 2 If UPS is in Battery Operation Mode Turn off your loads safely Briefly press OFF button and observe that INVERTER LED turns off Figure 3 14 Press and hold OFF button until audible warning silences and observe that battery indicator LED lights turn off Figure 3 15 m OVER LOAD BATTERY wmm E HIGH y NOVER LOAD 4 N Figure 3 14 Figure 3 15 A Before fully switching off the UPS operating in battery mode switch off the output by briefly pressing OFF button Page 12 12 2 3kvA v1 0 1 3 3 Operation Modes L2 Series has Line Interactive UPS technology When mains voltage and mains frequency are within the tolerance limits UPS performs Automatic Voltage Regulation AVR and over current protection transfers the mains voltage to loads and meanwhile charges the batteries When mains voltage and or mains frequency are out of tolerance limits UPS begins supplying loads with battery power discharge Switching to battery operation will not be sensed by the loads Thanks to its Automatic Voltage Regulation AVR feature L2 Series is able to reduce increase voltage transferred to output by 15 when mains voltage increased decreased at percentages between 10 to 25 If mains voltage is greater or less than normal voltage by more than 25 UPS begins supplying loads from battery L2 Series UPS has following oper
14. requency tolerances Voltage Voltage tolerances Frequenc Frequency tolerances Power factor THDv Crest factor 110 125 150 gt 150 Technolog Control Communication Transfer time Remote monitoring Cold start Operating temperature Relative humidit Maximum altitude Noise level Dimensions W x D x H 175 x 485 x 265 mm Weight kg Degree of protection Colour Internal battery quantit Ah External battery cabinet Standard socket STANDARDS Safety EMC UPS LIFETIME Page 20 L2 2 3kVAV1 0 1 AUTHORIZED TECHNICAL SERVICE L2 2 3kVA V1 0 1 Page 21
15. s 50Hz and UPS will start up Load indicator led can be progressed by pressing ON button and battery indicator LED can be progressed by pressing OFF button until desired settings achieved dj y hos aR parreny IT ES HIGH y g A N Cx INVERTER LOAD HE NoRMAL h iN OVER BATT OVER OUTPUT 100 EN TEMP HIGH CURR FAULT i FAULT A i e Y a Figure 3 17 ee y BATTERY OVER LOAD 32 an HIGH y INVERTER MN LOAD NORMAL N OVER BATT OVER OUTPUT 100 S TEMP HIGH CURR FAULT U FAULT LOW x A E Y Figure 3 18 Page 16 L2 2 3kVAV1 0 1 LED DISPLAY See nee LOAD INDICATOR BATTERY INDICATOR 50Hz 5 ATER 100 LOAD n OVER BATT OVER OUTPUT 100 TEMP HIGH CURR FAULT 60Hz i 100 220VAC 5 ATER 100 aac 230VAC LCD OVER BATT OVER OUTPUT 100 BATTERY 9100 TEMP HIGH CURR FAULT 240VAC 5 ATER 100 r areva ES 100 LOA To D OVER BATT OVER OUTPUT 100 TEMP HIGH CURR FAULT DN 100 rs 5 ATER ES 100 Z 5 gt O o LL LLI ad E sa O gt ou O sa n LOAD A ATTE OVER BATT OVER OUTPUT 100 TEMP HIGH CURR FAULT 100 CURRENT ONO O 100 BATTERY CHARGING sarro 100 Table 3 3 Settings Table Settings menu must be used by authorized personnel only Please contact our Technical Support Center for detailed information L2 2 3kVA v1 0 1 Page 17 4 Troubleshooting A Make sure you go through the table below before contacting the Tech
16. s case the Battery Failure test result should be disregarded N An Automatic Battery Test on batteries charged for at least 10 Cs hours should be regarded 3 6 Overload During overload UPS may run in normal operating conditions for below defined periods UPS shuts the output when the below defined periods are exceeded Loading Ratio Power VA Eee 2000S Ss eases 2 Running Time Table 3 3 Overload Table 3 7 Audible Warnings 2 times consecutively in 60 Ocerstion on Better seconds p y Battery Over temperature Battery High Table 3 4 Audible Warnings Table L2 2 3kVA V1 0 1 Page 15 3 8 Settings Menu The UPS has a settings menu where Mains Frequency Mains Voltage Sleep Mode and Battery Charging Current settings can be changed This menu consists of the following Mains Frequency Mains frequency options are 50Hz and 60Hz Mains Voltage Mains voltage options are 220VAC 230VAC and 240VAC Sleep Mode Sleep Mode options are On and Off Battery Charging Current Battery charging current options are 0 74 2A 4A 6A and 104 The UPS must be connected to mains and must be fully switched off before entering to Settings Menu Press and hold OFF button until an audible warning is heard meanwhile observe that NORMAL led turns on Figure 3 17 Along with the audible warning INVERTER led load and battery indicators first step led lights will turn on Figure 3 18 if the mains frequency i
17. s seconds Y Switch On Y On If output is off es fully switched v Turn on off audible warning Y Switch off fully Y Turn off output Table 1 3 Front Panel Operation Page 6 L2 2 3kVA v1 0 1 2 Installation 2 1 Placement UPS Placement Do not install the UPS on an uneven ground or in outdoors Note that ventilation holes on side covers must not be clogged Do not install the UPS in places with liquid installation or places subject to fire risks Do not install the UPS in places where it will be exposed to direct sunlight or affected of heat sources Heed to minimum distance requirement between the UPS and nearby walls and or devices Do not install the UPS in places where it may be subject to vibration or impacts Do not install the UPS in environments with excessive too high or too low humidity levels Do not operate the UPS in dusty or filthy environments Do not leave any materials on or around the UPS to facilitate and expedite maintenance and repair operations A The UPS may overheat if distance requirements are not met Moreover this may complicate maintenance and repair operations The UPS must be installed in a room with restricted access Authorized Personnel Only External Battery Cabin Placement Heed to UPS placement instructions when placing the external battery cabin L2 2 3kVA V1 0 1 Page 7 2 2 Back Panel i 1 5 o 2 2 3 3 SS 4 4 L 7 5 2 6 Figure 2
18. wn power source batteries Therefore there may be live power at the output even if the mains voltage is disconnected There is dangerous level of voltage in the UPS and it must be opened by an authorized service personnel only The UPS must be grounded in adherence to the rules Do not expose batteries to extreme high temperatures to prevent fire risks Do not attempt to open the battery Chemical composition of the battery may be dangerous for your skin and eyes Adhere to all regulations that govern disposal of waste batteries Safe Handling Be careful while carrying loads Do not carry heavy loads without help Slide roller devices on smooth and even surfaces Do not use slopes with angles over 10 Adhere to following recommendations about load weights An adult can carry loads up to 18 kg weight Two adults can carry loads up to 32 kg weight Three adults can carry loads up to 55 kg weight Use pallet jack forklift or similar devices for carrying loads over 55 kg weight Keep packaging material for use in case the UPS has to be transported to an authorized service or to another location UPS Safety The UPS must be safeguarded against voltage overload or short circuit voltages by means of a readily accessible circuit breaker Do not operate the UPS at environment temperatures or relative humidity that exceeds the limits given in the manual Never operate the UPS in liquid environments or