Home

2201 Rack Chassis User Manual

image

Contents

1. User Manual 2 1 EdgeAccess Universal Chassis System 7 Slide the power monitor board into the slot next to the power supply s and firmly seat it in the power distribution board then push in the retainer latches at the front 8 Mount the chassis in a standard 19 inch relay rack or in a 23 inch rack The chassis ships with mounting brackets for a standard 19 inch relay rack e Fora 19 inch rack position the chassis in the rack and secure the brackets to the rack with four screws e For a 23 inch rack secure the optional 23 inch extender brackets with four screws then position the chassis in the rack and secure the brackets to the rack with four screws 9 AtALRM and ALRMC common or ground at the rear panel connect a device to receive alarm information see Figure Error Reference source not found Figure 2 2201 Rear Panel 10 To connect power to the power supply s follow these steps e Foran AC supply plug the power cord into the socket at the rear then plug the cord into the power source e For a DC supply loosen the screws for the GND and BV terminals at the rear then slide the wires under the square washers and tighten the screws See Figure 2 Connect the power cables according to the power source e For 48 V or 24V input connect V to GND connect V to BV e For 48 V or 24V input connect V to BV connect V to GND Note To turn off the power unplug the AC power cord or turn off the DC supply 11 In
2. buzzes For specifications for the power supplies see Chapter 3 Figure 1 shows the 2201 with the power monitor board The chassis includes alarm output terminals at the rear panel Use the ALRMC and ALRM terminals to connect to an external device that can receive alarm information If an alarm condition occurs in the chassis power supply notification is sent to the external device The front panel includes one pushbutton for alarm acknowledgement which turns off the buzzer and two LEDs that light red if the primary or secondary power fails 2201 Rack Chassis User Manual 1 1 1 2 EdgeAccess Universal Chassis System 2201 Rack Chassis User Manual EdgeAccess Universal Chassis System Chapter 2 Installing and Troubleshooting the Chassis This section describes how to set up and install the chassis Installing the Chassis Before setting up the chassis make sure these items are available e Chassis with application modules e Power cables 14 or 16 gauge wire for DC power e Contact wires for the Alarm optional Caution Equipment intended only for installation in a RESTRICTED ACCESS LOCATION accessible only to electrically skilled persons and electrically instructed persons with the proper authorization Follow these steps to install the chassis 1 Plan the installation considering these characteristics e Place the chassis within 7 ft 2 134 m of the power source e Plan to use one or more of these locations fo
3. located inside the power supply one fuse for each group of slots If needed you can move a modem from a faulty slot to an empty slot For more information see Table 1 e Ifa fuse blows after you replace it it can indicate a fault on a modem on that output circuit To isolate a modem swap each modem on that output circuit to slots on the other output circuits If a different fuse blows the fault is on that modem replace it For more information see Table 1 Table 1 Power Supply Cable Pinout Pin Number Function 1 Return 2 Key 3 4 Power for slots 1 2 and 3 5 6 Power for slots 4 5 and 6 7 8 Power for slots 7 8 9 and 10 9 10 Return 2201 Rack Chassis User Manual 2 3 2 4 EdgeAccess Universal Chassis System 2201 Rack Chassis User Manual EdgeAccess Universal Chassis System Chapter 3 Specifications Chassis dimensions 8 8 Hx 19 W x 12 8 D 223 5 mm x 482 6 mm x 325 1 mm Weight Chassis empty 7 7 lbs 3 49 kg AC power supply 9 0 Ibs 4 08 kg DC power supply 3 0 Ibs 1 36 kg Power supply monitor board 0 5 Ibs 0 23 kg Power Redundancy Optional AC AC DC DC or AC DC AC power supply 115 VAC 10 47 to 63 Hz 2 2 A Max 230 VAC 10 47 to 63 Hz 1 1 A Max optional Heat dissipation max 825 BTU hr DC power supply 48 VDC 5 A Max Heat dissipation max 825 BTU hr Environment Operating temperature 0 to 50 C Humidity 10 to 95 non condensing 2201 Rack Chassis User Manual 3 1 3 2 E
4. 0 T o I O lt o O B LL CANOGA PERKINS 2201 Rack Chassis User Manual EdgeAccess Universal Chassis System CAUTION This product may contain a laser diode operating at a wavelength of 1300 nm 1600 nm Use of optical instruments e g collimating optics with this product may increase eye hazard Use of controls or adjustments or performing procedures other than those specified herein may result in hazardous radiation exposure Under normal conditions the radiation levels emitted by this product are under Class 1 limits in 21 CFR Chapter 1 Subchapter J ATTENCION Cet quipement peut avoir une diode laser mettant des longueurs d onde allant de 1300nm 1600nm L utilisation d instruments optiques par exemple un collimateur optique avec cet quipement peut s av rer dangereuse pour les yeux Proc der des contr les des ajustements ou toute proc dure autre que celles d crites ci apr s peut provoquer une exposition dangereuse des radiations Sous des conditions normales le niveau des radiations mises par cet quipement est en dessous des limites prescrites dans CFR21 chapitre 1 sous chapitre J NOTICE This device contains static sensitive components It should be handled only with proper ElectroStatic Discharge ESD grounding procedures NOTE Cet quipement contient des composants sensibles aux d charges lectro statiques Il doit absolument tre manipul en resp
5. dgeAccess Universal Chassis System 2201 Rack Chassis User Manual EdgeAccess Universal Chassis System Appendix A Warranty Information Current Warranty information is available on line in the Client Login Area of the Canoga Perkins web site www canoga com or by contacting Technical Support at 800 360 6642 voice or fiber canoga com email 2201 Rack Chassis User Manual A 1 CANOGA PERKINS CANOGA PERKINS CORPORATION 20600 Prairie Street Chatsworth California 91311 6008 USA Phone 818 718 6300 FAX 818 718 6312 Web Site www canoga com Email fiber canoga com
6. ectant les r gles de mise la terre afin de pr venir de telles d charges 2201 Rack Chassis User Manual EdgeAccess Universal Chassis System NOTICE Canoga Perkins has prepared this users manual for use by customers and Canoga Perkins personnel as a guide for the proper installation operation and or maintenance of Canoga Perkins equipment The drawings specifications and information contained in this document are the property of Canoga Perkins and any unauthorized use or disclosure of such drawings specifications and information is prohibited Canoga Perkins reserves the right to change or update the contents of this manual and to change the specifications of its products at any time without prior notification Every effort has been made to keep the information in this document current and accurate as of the date of publication or revision However no guarantee is given or implied that the document is error free or that is accurate with regard to any specification Canoga Perkins Corporation 20600 Prairie Street Chatsworth California 91311 6008 Business Phone 818 718 6300 Monday Friday 7 a m 5 p m Pacific Time FAX 818 718 6312 24 hrs Web Site www canoga com Email fiber canoga com Copyright 1994 2005 Canoga Perkins Corporation All Rights Reserved EdgeAccess 2201 Rack Chassis User Manual Product Number 6910040 Rev K 01 2008 EdgeAccess and Canoga Perkins are registered trademarks of Canoga Pe
7. r the connection to Earth Ground e The grounding prong on the AC power cord e The ground of the DC terminal strip e The mounting hardware for the rack if the rack is tied to Earth Ground e Place the chassis adjacent to other Canoga Perkins or related equipment 2 Unpack the chassis cables and modems and inspect all parts for damage and compare them with the packing list Set the packaging aside in case you need to return the equipment 3 Onthe power monitor board in the slot next to the power supply s check the switch and jumpers a Set Power Switch to A for one power supply or to A B for two power supplies b Install a jumper at W1 to isolate the Signal and Chassis grounds or at W2 to connect the grounds then check that a jumper is installed at W4 4 On the Power Distribution board located inside the back panel install a jumper at W1 if you will connect a normally closed alarm or at W2 if you will connect a normally open alarm 5 Remove the front cover for the power supply then slide the power supply s into the front of the chassis Install the primary A supply in the lower bay and the secondary B supply in the upper bay Secure each retaining screw finger tight and then re install the power supply cover 6 Plug each power supply output cable into its connector on the power distribution board plug the primary A supply into the lower connector and the secondary B supply into the upper connector 2201 Rack Chassis
8. rkins Corp To reference Technical Advisories and Product Release Notes go to Canoga Perkins website http www canoga com ii 2201 Rack Chassis User Manual EdgeAccess Universal Chassis System Table of Contents Chapter 1 Overview assis nee o Soie de PME uU 1 1 Chapter 2 Installing and Troubleshooting the Chassis 2 1 Installing th ChassiS cido pees GEN HO ERE EE PITE einer sinus 2 1 Troubleshooting the Power Supply S eese nnne tnter enne 2 3 Chapter 3 Specificatlons visor alan NE QE NN SERES Qd 3 1 Appendix A Warranty Information A 1 List of Figures Eigure 1 2201 Rack Chassis eR nee en ee teo etit Pe e ihe et efect 1 1 Figure 2 2201 R r Panel aie Ei ii LEN 2 2 List of Tables Table 1 Power Supply Cable Pinout ss 2 3 2201 Rack Chassis User Manual iii EdgeAccess Universal Chassis System 2201 Rack Chassis User Manual EdgeAccess Universal Chassis System Chapter 1 Overview The 2201 Rack Chassis houses and supplies power to Canoga Perkins fiber optic modem modules in the 2200 series including the 2240 2262 2270 and 2290 Although the chassis is not managed it supports up to 10 fiber optic modems Figure 1 2201 Rack Chassis The 2201 supports one or two AC and or DC power supplies in the chassis The power monitor board includes an LED for each power supply if a supply fails the LED for that supply lights red and an alarm
9. sert the modems into the chassis for details see the user manual for each modem 12 Turn on the chassis power supply s The LEDs on all modules may blink during the power on sequence then the PWR LEDs light steady 13 To configure each modem in the chassis see the user manual for that modem 2 2 2201 Rack Chassis User Manual EdgeAccess Universal Chassis System Troubleshooting the Power Supply s If the Power LED on the power monitor board lights red and the alarm buzzer sounds it indicates a problem with the power supply Press the alarm reset switch to silence the alarm then make these checks e If the Power Monitor board indicates a fault but the Power LEDs on all modems are lit check that the A A B switch on the Power Monitor board is set correctly for one A or two A B power supplies e Unplug the cable for the failing power supply and check the voltage between ground on pins 1 9 or 10 and supply on pins 3 4 5 6 7 or 8 see Table 1 For an AC supply 9 VAC is normal For a DC supply 9 or 9 VDC is normal e Check the voltage between pins 3 and 4 5 and 6 or 7 and 8 see Table 1 For an AC supply normal voltage is 18 VAC For a DC supply normal voltage is 18 VDC e If all voltages are faulty unplug the power cord for the faulty supply and check the main fuse for that power supply e If voltages are faulty on only one pair of pins unplug the power cord for the faulty supply and check the secondary fuses