1. 10 TROUBLESHOOTING 10 SD LEPINI CANONS acabe oe EUER Na 10 COMBINATION POSSIBILITIES amp TRAPPING RISKS 11 CE MARKING 15 COMER TIAIN 16 Introduction If you want to avoid unnecessarily risk of trapping when installing several Ropox electrical height adjustable frames in one system you can do so by using our Smartbox The intelligent anti trapping system can be used when you have more electrical frames mounted next to each In these situations the Smartbox system will remove eliminate the extra risk of trapping which is not covered by the standard Safety strips and safty stopplates Up to 4 FlexiElectric can be connected side by side with the use of the Smartbox Above this you can also connect up to 4 VertiElectric side by side This means that you can connect a maximum of 8 Smartboxes in one system To see your combination possibilities please refer to section 9 omartboxes must only be used together with Ropox products such as FlexiElectric VertiElectric or 4SingleElectric and only when mounting and daily use are according to this manual and the relevant manuals for FlexiElectric VertiElectric or 4SingleElectric The Smartbox will only be used if you have two or more units mounted close together and in this situations you
2. Side 12 2 14 e Side 13 47 4118 a L 3 La 1 3 5 7 Side 14 10 hereby declare under sole responsibility that the following product 30 69001 Smartbox conform to the following directives and standards DIRECTIVES 73 2 3 Low voltage directive e 89 336 EEC EMC Directive STANDARDS DS EN 60335 1 2002 5 61000 6 1 2001 5 61000 6 3 2001 Side 15 11 Complaints We refer to our general Terms of sale and delivery on our homepage www ropox com Side 16
3. master Flexi 3 DIP switch Pos 10 switches from OFF to ON NS 4Flashes Numbers Smartboxes variates from original Communication error Stopping all movements on master Awaiting feedback Stopping all movements on this Smartbox Faulty DIP switch settings Stopping all movements on this Smartbox Number of Smartboxes variates Stopping all UP movements on all Smartboxes downward is ok if the Safety strips is ok oide 10 9 Combination possibilities amp trapping risks When you have a combination of Ropox electrical frames you can remove all trapping risk by using the Ropox Smartbox On top of using the standard Safety strip and safetystopplates this shows where the trapping risk will occur when putting up a system like this By using the Smartbox you will solve this and make your system even safer to use IMPORTANT It is very important that the layout is according to this schematic and the Smartbox has been installed according to this manual and the manuals for FlexiElectric and VertiElectric has been followed Arrows shows the extra risk of trapping that are covered by using this Smartbox Ex FlexiElectric No 3 will stop upwards movement if safetystopplate on No 2 4 amp are activated or the Safety strip on Flexi No 1 amp 5 are activated Wallunit mounted on a VertiElectric ALWAYS even No Worktop mounted FlexiElectric ALWAYS uneven Side 11
4. need one Smartbox per Controlbox in the system This document must ALWAYS be kept with the product and have been read and understood by the user The correct use operation and inspection are decisive factors for efficient and safe performance Prior to assembly check that all parts have been provided See list of components page 3 Side 2 List of components Smartbox 30 69001 8 The smartbox comprise 1 Smartbox 98002100 2 Extension cable 98002104 L 3 5 cm male male plug Pos 2 to safety strip 3 Communication cable 98002105 L 250 cm male male plug Pos 3 to previous smartbox 4 Communication cable 98002106 L 50 cm modular cord Pos 4 to controlbox 5 Communication cable 98002107 550 Din 7Polet plug Pos 5 to controlbox 6 Extension cable 98002008 2250 cm male female plug Pos 6 to next smartbox Pos 3 11 Spiral extension cable 98002016 225 100 cm black to safety strip Between Pos 6 amp 3 at the smartboxes Common parts 96000155 Adhesive pads Cable tidy strips The equipment should always be assembled by competent personnel oide 3 1 pc 1 pc 1 pc 1 pc 1 pc 1 pc 1 pc 1 set 5 pcs 10 pcs 11 3 Connection of Smartbox 3 1 Descriptions 6 Connection to next Smartbox Comm Out 10 Dip switch indicates first and last Smartbox connected 3 Communication input from previous Smartbox Comm In 9 Dip switch for Smart
5. PDT AW 1102 Better ways to better days BLE SEF Smartbox 30 69001 8 User Manual Mounting Instructions Keep always this folder with product PDF 5956 01 01 2011 Contents 1 10 11 1 INTRODUCTION 2 LIST OF COMPONEN DS 3 CONNECTION OF SMART BOX CE VE VUA SR NUN 4 Dik DSTA PU 4 3 2 cdConneclomor smaribox CONTIOID ON ca 2 LONEN DO YOS sae cati esta o data estatal ema aiat idea id 2 3 4 Connection of 8 Smartboxe in tb ette INITIALIZING THE SMART BON 7 41 Numbering the Smartbox the 8 polet DIP switch Pos 9 222 7 4 2 Indicate Set first and last Smartbox in the system Pos 10228882 7 45 Pom Master YOSEL 52 ER 8 PERFORMANCE TES pec 9 6 1 Performance test electrically operated 9 CLEANING AND MAINTENANCE 10
6. artbox ON Smartbox OFF Smartbox OFF Smartbox OFF Smartbox No 2 Smartbox No 4 Smartbox No 6 Smartbox No 8 FlexiElectric FlexiElectric FlexiElectric FlexiElectric First Smartbox ON Smartbox OFF Smartbox OFF Smartbox OFF Smartbox No 1 Smartbox No 3 Smartbox No 5 Smartbox No 7 Side 6 4 Initializing the Smartbox Up to 4 FlexiElectric can be connected side by side by the use of the Smartbox Above this you can also connect up to 4 VertiElectric side by side This means that you can connect a maximum of 8 Smartboxes in one system To see your combination possibilities please refer to page 9 N All Smartboxes are given a unique number FlexiElectric Can only achieve uneven numbers as 1 3 5 og 7 VertiElectric Can only achieve even numbers as 2 4 6 og 8 N Smartbox No 3 is ALWAYS master and must ALWAYS be a part of your system 4 1 Numbering the Smartbox on the 8 polet DIP switch Pos 9 Set the dipswitch with the number of the unit FlexiElectric or VertiElectric this example is for FlexiElectric No 3 which also are the master box See also schematics page 8 A 4 2 Indicate Set first and last Smartbox in the system Pos 10 You need to tell the system how many Smartboxes you have in the system You have to indicate set the first and the last Smartbox in the system Use the DIP switch pos 10 by setting No 1 in ON position both on the first and also on the last Smartbox All other Smart
7. box settings naming the Smartbox 8 Led light to be used at power up and trouble shooting 2 Connection of Safety strip SAFETY LED SELECT COMM END COMM STRIP INFO MODULE IN BUS OUT TERM 8 119 3 10 ROPOX SMARTBOX HC 4 5 78 128 CONTROLBGX CONTROLBOX HANDSET HANDSET SAFETY INPUT HANDSET TABLE CABINET 4 Connection to Controlbox modular plug Controlbox pinch input 5 Connection to controlbox Din plug To controlbox handset 7 Connection of the control switch for the table 12 Connection of the control switch for the VertiElectric optional Pos 3 is not being used on the first Smartbox in the system Pos 6 is not being used on the last Smartbox in the system Side 4 3 2 Connection of Smartbox to controlbox Motor connections Safetystrip connection Antipinch connection to Smartbox Din plug To controlbox handset 4 VertiElectric Table 3 3 Connection between Smartboxes From Smartbox Com From Smartbox Com out to Smartbox Com out to Smartbox In From Smartbox Com out Com In Not in use if this is the to Smartbox Com In Not in use if this is the first Smartbox in the Use cables pos 6 11 3 Part No last Smartbox in the system 98002008 98002016 98002105 system ROPOX Side 5 3 4 Connection naming of 8 Smartboxe a system VertiElectric VertiElectric VertiElectric VertiElectric Last Sm
8. boxes in the system has to be OFF See also schematics page 8 4 3 Perform Master reset Connect main power to all the controlboxes in the system Perform a reset of the master Smartbox No 3 Deactivate the master by setting DIP switch Pos 9 to OFF Activate again by setting it back to ON When you make this reset the master will count the numbers of Smartboxes connected in the system and the LED Pos 8 will flash the numbers After this procedure the LED will turn off and work as normal By activating the Safety strip the LED will light up Make a performance test according to section 6 Side 7 5 Examples See more combinations page 12 ast Smartbox Smartbox No 4 12 1234 5678 First Smartbox ON Smartbox No 3 Master Smartbox OFF L ast Smartbox ON Smartbox No 4 Smartbox No 2 mh 4 12345678 12 1234 5678 Mme 12345678 12 First Smartbox Smartbox No 1 Smartbox OFF 1234 585679 ast Smartbox ON Smartbox No 2 Smartbox OFF Smartbox No 4 12345678 17 12345678 12 vu wh 12345679 Frst Smartbox ON Smartbox No 3 Master Smartbox OFF Smartbox No 6 y_rsstd C 12345678 Smartbox No 3 Master Side 8 Performance test 6 1 Performance test electrically operated frame After installation and prior t
9. o use all anti pinch functions of FlexiElectric and VertiElectric must be tested The test must be carried out by competent personnel Subsequently the test shall be carried out at least once a year 10 11 12 13 14 Testing prior to connection of mains voltage Check that the mounting instructions have been observed Check that all cables have been connected correctly and that the plugs have been pressed home Check that there are no load on the FlexiElectric or VertiElectric frames Check that there is nothing preventing the FlexiElectric or VertiElectric from moving freely within the height adjustment range Now connect mains voltage to the control unit and proceed as follows Check that LED on master Smartbox No 3 flashes with the number of connected Smartboxes For every FlexiElectric the following tests must be carried out Press DOWN on the control switch move the FlexiElectric frame to bottom position and check that the movement is even and smooth Press UP on the control switch move the FlexiElectric frame to top position and check that the movement is even and smooth Test of the safety between the FlexiElectric frames Safety strip downwards movement on every FlexiElectric must be tested See also instructions in the FlexiElectric Manual Move the first FlexiElectric to the top position and the next FlexiElectric to the bottom position Press UP on the control switch next FlexiElect
10. ric and let the frame move 2 5 cm upward Now activate the safety strip on the first FlexiElectric by pressing it lightly The frame must stop the upward movement move 1 2 cm downward and stop Test the rest of the FlexiElectric frames according to these procedures to make sure that all risk of trapping has been tested and found safe Test of the safety between the FlexiElectric frames and the above VertiElectric First perform a performance test according to the VertiElectric Manual on each unit Test one FlexiElectric at a time by moving it upwards pressing the safety stopplate on the above VertiElectric shall stop the upward movement move 1 2 cm downward and stop Follow the above instructions to make sure that all combinations trapping risk has been passed refer to combination possibilities section 9 If all these tests are ok the system of frames are ready for use Side 9 l Cleaning and Maintenance 7 1 Cleaning N The frame must not be connected to the mains voltage during cleaning A N Do not flush electrical components with water N Smartbox must only be cleaned with a soft dry cloth 8 Trouble shooting 8 1 LED indications No light Everything is ok X oteady light Safety strip activated or fault on safety strip on this omartbox RE NM 1 Flash 2 Flashes Awaiting feedback from other smartboxes 3 Flashes Faulty DIP switch settings 2 8 Flash Indicates the number of connected Smartboxes at power up or when