inBio-160 Installation Guide
Contents
1. CoESS Advanced Solutions Total Security 1 Cautions Please pay attention to the following items Mis operation may lead to equipment failure or personal injury 1 Do not power on the system before the installation is complete Do not install or repair while power is on 2 All external devices must be grounded 3 It is recommended that all wires run through PVC or galvanized conduit 4 We recommend that the exposed part of all wires be shorter than 4 mm to avoid short circuiting or communication failure 5 It is recommended that the card reader and the exit button be installed at a height of about 1 4 1 5m 6 It is recommended to use separate power supplies for the control panel and the lock Description of normal working state Power on the system the power indicator red is on constantly in normal working state the run indicator green is flashing the communication indicator yellow is flashing when communicating 2 Components Panel Box Appearance Panel Box Inside 3 Installation After the following installation fix the panel to the track first and then install other components 4 LED Indicators and Wire Illustration 1 Meaning of LED indicators LINK indicator green Constant light indicates TCP IP communication is normal ACT indicator yellow Flashing indicates data is transmitting through TCP IP communication EXT RS485 indicator yellow amp green Flashing indicates it is sending or receivi
2. As shown in the figure above turn number 8 of the DIP switches of the 1 and 8 at ON status O 201 Circle Drive N Suite 116 Piscataway NJ 08854 Tel 732 412 6007 Fax 732 412 6008 www zkaccess com
3. en when power is on so COM and NO terminals should be used For NC lock it is normal closed when power is on so COM and NC terminals should be used 2 The control panel supports dry mode and wet mode by using the jumper For wet mode short terminals 2 3 and 4 5 The control panel and the lock use separate power supplies One is connected with 12V and 201 Circle Drive N Suite 116 Piscataway NJ 08854 Tel 732 412 6007 Fax 732 412 6008 www zkaccess com CoLESS Advanced Solutions Total Security GND of POWER interface for the control panel the other is connected with V and V of LOCK interface for the lock For detailed settings for dry mode and wet mode please refer to the Installation Guide The factory default is dry mode 3 For the Wiegand reader and the inBIO reader the standard power supply is 12V 3A So we do not recommend that the lock and the control panel share a common power supply If it is necessary to do so we suggest using a larger one such as 12V 5A Not including the power reserve there are 2A current for the lock For the common electrical lock the stand by current is 300mA the maximum current is 500mA the maximum connected locks is 4 4 When the electrical lock is connected to the access control system you need to parallel an Fr107 diode included in the package to prevent self induced EMF from affecting the system Do not reverse the polarities Diagram on Pa
4. eparate power supplies to ensure steady operation 8 Equipment Communication The PC software can communicate with the panel according to the communication protocols RS485 and TCP IP for data exchange and remote management The communication cable should be as far away from high voltage lines as possible Do not keep the communication cable parallel to power cords or bind them together I TCP IP Communication 1 Control Panel 2 Control Panel 8 Control Panel Ds RS485 Communication 1 Control Panel 2 Control Panel 8 Control Panel 1 Internationally accepted RVVP shielded twisted pair wires should be used for communication to effectively avoid interference RS485 communication wires should be connected by means of bus cascade connection 2 It is recommended that the RS485 bus should be less than 600 meters to help aid communication stability 3 One RS485 bus may hold 63 control panels but it is not recommended to connect with less than 32 access control panels 4 For the inBIO reader connection if the reader and the control panel use the same power it is recommended that the wire be less than 100 meters If greater length is required please use a separate power supply 5 To enhance the stability of communication when the wire is longer than 300 meters it is necessary to keep the number 8 switch of the first and last control panel at ON status That adds the RS485 terminal resistance 120 ohm of the two devices to the system
5. nel 4 Insert a screw driver to the rectangular hole in the four corners of the panel back Push it in until hearing the click sound Then remove the case from the panel The following is wet mode lock connection with external power supply 7 485 Reader GnBIO Reader Connection The control panel supports inBIO biometric verification reader and Wiegand reader All inBIO reader operations are execute from the control panel including storage verification etc Re registering fingerprints is not required when replacing the reader Make the biometric reader connection inBIO reader connection First of all set the 485 address device number of the reader by software DIP switch or keypad Readers 1 and 2 the odd number is for the entry reader and the even number is for the exit reader are for door number 1 And the 485 address is 1 2 as in the figure below For more information please refer to the software user manual In the inBIO reader connection a single EXT485 interface can supply 500mA 12V current maximum So the entire current consumption should be less than this max value when the reader shares power with the panel For example when you use the F11 reader the standby current is less than 100mA the max current is less than 120mA for the inBIO reader connection the max number is 4 readers For this type of panel 2 readers can be connected at most For some of the devices with much greater consumption we suggest using s
6. ng data through RS485 communication PC RS485 indicator yellow amp green Flashing indicates it is sending or receiving data through RS485 communication RUN indicator green Flashing indicates the system is working normally CARD indicator yellow Flashing indicates a card is punched on reader Diagram on Panel 3 Ethernet Interface DIP Switch PC RS485 Interface Auxiliary Output Control Panel Power 5 DIP Switch Settings 1 Switches 1 6 are used to set the control panel number in RS485 communication It is adopted binary coding and little endian the address number is set by placing these 6 switches as shown in the figure below Before setting the address please keep the system powered off Place the corresponding switches to the desired status The address number should not be repeated in the network For example Set the device number as 39 39 1 2 4 32 the switch s status is 111001 that is set number 1 2 3 and 6 switches at ON 2 Number 7 switch is used to restore the factory defaults Switch it three times within 10 seconds and restart the device then all data will be cleared and the system restored to factory default settings 3 Number 8 switch is used to set terminal resistance in RS485 communication Switch it to ON status which adds a terminal resistance of 120 ohm between 485 and 485 6 Lock Connection 1 The control panel provides lock control output interfaces For NO lock it is normal op