1. 60m Large 120m X Large 120m 17 5 Maintenance and Service Maintenance of your Super ActivO is required every 500 hours in order to insure trouble free performance The Super ActivO keyboard will display a message indicating that 500 hours of operation have been reached by displaying Needs Service If you have a good pair of hands and follow these instructions carefully this 3 step procedure should take you about 1 hour CAUTION DISCONNECT POWER FROM THE SUPER ACTIVO BEFORE BEGINNING PROCEDURE BEGINS NEXT PAGE 18 Step 1 Clean Dust Filter 25 in picture at bottom of this page a Remove black front grill panel 26 by unscrewing 6 screws What you will then see is shown in the picture at the bottom of this page b Loosen 6 screws in frame around dust filter 25 so you can slide filter out Do not remove the earth cable connected to the grill c Gently slide filter up and out of its frame see picture d Place the filter under warm tap water and wash out dust It is ok to use a mild liquid soap if needed to loosen the dust Rinse and dry ok to use hair dryer e Slide Dust Filter back into its frame and retighten loosened screws 19 Grill s ground cable 4 outlet amp Ground connection 5 Front Grill 26 Dust Filter 25 Electrical Ozone Filtering Connector unit 17 to Singlet Step 2 Clean Ozone Ge
2. and only then connect it to the power source socket 6 1 Controller settings 9 ActivO HO Beer Q Press STOP Red button to Reset o STOP RESET The display will present a code followed by the alternating prompt Ready and Set Room Size C Select Room Size by pressing the respective keypad button Note You may choose between the following 4 room sizes Small for room volumes below 30m Medium for room volumes between 30m and 60m Large for room volumes between 60m and 120m Lele X Large for room volumes from 120m to 500m 10 The display will now prompt Set Time Select the Short Intermediate Long time cycle D by pressing the respective button on keypad Note Select length of cycle to correspond L5 Short Cycle Time Light odor Intermediate Cycle Time Average odor Long Cycle Time Strong odour x Q Refine Time setting optional by pressing the Up or Down blue arrow buttons to extend or to shorten the operation cycle time respectively Please refer to reference chart on page 13 lA Up to extend cycle time 11 Down to shorten cycle time Note Time is indicated on LCD in hours and minutes h hours and m minutes For example 3 hours and 20 minutes would be indicated so 3h 20m 12 Q Press green I button for START CAUTION Before starting operation verify that the treated area h
3. Super ActivO User Manual 2014 E nvironmentally activated by ECC i recu User Manual Table of contents Unpacking is aide va paa si cee Qi raa ERE ERR DERE DEXEE AE EUR E ME based General Information ob oEN E ERE SU ER AVENA SD Declaration of Conformity is eres eer nde ara ex eee nere Exe ovi oie Safety Precautions amp Warnings c eeeee eee eee eee eee ee ees E The Super ActivO control panel and other 5 Technical Specifications asa eed e Controller Stings eer eee pe Eat oven redes dest Activation Deactivation and Total Operating Time 13 Maintenance and Service eeeeeeeeeeeeeeeeeeee eee eee ene eene eee L4 Troubleshooting cire cai cas yas 3o daro Seo aRCUE kao FP ERI o TIRE Ea Reina Sra LER uis epu WALPANly PRA UNPACKING Open top flaps of carton Gently place carton on its side Lift unit up slightly and then pull out by rolling on its wheels C Place handle on top panel and fasten 3 hex screws on each side Handle 1 General Information A Ecozone s Super ActivO is a mobile and easy to use deodorizing system for indoor use This robust computer controlled and automatic system is characterized by high safe
4. as been vacated of people animals plants and items containing natural rubber EXAMPLES OF USE OF ITEMS CONTAINING NATURAL RUBBER Items made of natural rubber gum are many and differ in their rubber content the more rubber content the greater their susceptibility to degradation by ozone Among the common items that may contain natural rubber are computer keyboards rubber under the keys floor squeegees tubes for bicycles crepe soles for shoes rubber bands various gloves Latex smoked sheets underlay and more The common sense rule when in doubt about whether the item contains natural rubber remove the item before treating the space Or alternatively smear the item s surface with Vaseline or equivalent before exposing it to ozone TUBING LINING GASKET OLD REFRIG DOORS UNDERLAY i 2 FOR SHOE SOLES 13 Eg START Operation Place unit in CENTER of room When treating smaller rooms you do not need to use air movers in order to circulate ozone since your Super ActivO sends ozone at a high rate of 265 CFM to the ceiling where it spreads out and drifts downward to cover all surfaces Note If treating a crawl space attach 4 diameter ducting to Super ActivO Outlet page 5 When using Super ActivO in this manner there will be no ozone deactivation However ozone in the crawl space will deactivate naturally typically in 3 6 hours The display will prompt you to Get Out of Room an
5. d the amber Hazard light will begin flashing Important The system will begin generation of ozone after a 60 second delav in order to allow vou to You must leave the room immediately Windows and doors Remaining in the treated area while unit is in operation or entering before completion of cycle may be hazardous to your health should be closed to prevent ozone leakage Outside the room you will hear a prolonged audio alert signal indicating that ozone generation has begun After the full operation cycle is completed including removal of the ozone you will hear a second audio alert signal indicating that operation is completed gt Upon entering the treated room the display should read Operation Complete and the amber light should have stopped flashing N CAUTION In the event indications do not correspond to the above leave the room immediately and call for ECOZONE service After the operation has ended and before moving the machine elsewhere be sure to disconnect the power cord from the power socket 15 ATTENTION If at any time you need to reset the keyboard settings press STOP button red O on keypad Activation Deactivation and Total Operating Times Total Cycle Time T Room Volume Small lt 30 Medium 60m Large 120m X Large gt 120m Room Volume Small lt 30 Medium
6. er s decision to replace a machine the customer should arrange on his account to deliver the machine to manufacturer s facility for reparation or for replacement by the manufacturer 24 THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ALL OF WHICH ARE EXPRESSLY EXCLUDED AND DISCLAIMED ECOZONE WILL NOT BE LIABLE FOR LOSS OF PROFITS ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES WHICH PURCHASER MAY SUSTAIN OR PUNITIVE DAMAGES EVEN IN THE EVENT OF NOTICE OF THE POSSIBILITY OF SUCH DAMAGES IN NO EVENT SHALL LIABILITY UNDER THIS WARRANTY EXCEED THE PURCHASE PRICE OF THE SUPER ACTIVO PRODUCT SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE Contact information Ecozone Technologies Ltd Hasharon Industrial Park P O B 5014 Kadima 60920 Israel Phone 972 98 91 24 41 Fax 972 98 91 24 45 info ecozone technologies com www ecozone technologies com 25
7. ical Connector to Singlet Connecting Screws for Filtering unit Ozone Filtering Unit 17 Step 3 Close black front grill panel 26 picture above page 16 a Replace the front grill making sure the dust filter is on the inside of the unit Make sure the earth cable to the grill is completely inside the unit b Re screw the 6 screws around the frame of the panel 6 Troubleshooting Problem Possible Solution 22 Display is blank and keypad does not function Check power cord connections Check fuse picture below If fuse is blown replace it If it blows a second time STOP and call Ecozone for assistance Display prompts Ready but keypad does not function Disconnect and reconnect power cord Wait for Ready prompt Press STOP button red on keypad Press hard RESET button yellow on keypad D D we Mo Red light fault indication is ON and the display indicates one of the following fault codes a AL Presso Stat b AL Micro Switch Make note of fault code indicated on the display C Disconnect power cord CALL ECOZONE service Display shows Needs Service This notification will appear every 500 hours of use Upon notification please refer to Section 6 above page 15 Other Call local ECOZONE distributor for technical support 23 7 Warranty WARRANTY ECOZONE warrants to the original re
8. ignal 20 This system is equipped with a ventilation inlet and a ventilation DO NOT BLOCK inlet outlet or place foreign objects in their vicinity which may block air flow Place unit in the CENTER of the room Ory m DO NOT disconnect cable cord from mains socket before the operation of the system is completed AN AVOID ELECTRICAL SHOCK This unit is supplied with a earthed cable Attempting to bypass the earth or to connect the unit to an un earthed socket is strictly prohibited Under no circumstances should the unit be operated with the front panel grill loose or missing Prior to removing the grill for maintenance always disconnect the unit from power There are no user serviceable parts inside the Super ActivO removal of back panel by unauthorized personnel will result in voiding the WARRANTY 3 Technical Specifications Mp 5 1 Description The Super ActivO system is a portable high duty and rugged system It features the most advanced technology in the field of odour control and air treatment The Super ActivO employs Ecozone s state of the art and patented Singlet Unit which is characterized by relatively high activation rate and enhanced reliability 5 2 Technical Specifications Input Voltage 230V 50Hz Air Flow Rate 450 m3 n Ozone output 12g h 12 000 mg h Operation Fully Automatic Activation amp Deactivation Cycles Cycle time Minimum 15 minutes Maximum 48 hours With special inp
9. nerating Cores Singlets 15 below a There are two 2 Singlets to remove and clean They are shown side by side as 15 in this picture Leading Screws for Singlet 20 Singlet PentaRod 15 2 Nuts for Singlet Ozone Filtering unit 17 2 of 3 Screws for Filtering unit b Remove the electrical connector from each purple circles picture on next page c Unscrew the 2 nuts holding each Singlet unit white circles above d Gently pull out in parallel each Singlet from its leading screws exposed in white circles in picture below shown after removal of Singlets Handle unit carefully e Clean the units under warm tap water especially the gaps between the tubes You may use a soft brush to remove any accumulated dirt Use care not to wet the electrical connector f Dry the Singlet units with a soft towel Continued Next Page Note the tubes used in the Super ActivO are unlike tubes used in competitive ozone machines which are often fragile and easily broken The Super ActivO tubes are specially designed for use in rugged DR disaster recovery environments 21 g Re mount each Singlet on its leading screws slide in parallel Be sure to re insert Singlets so that the 3 tubes are on the side facing you Re attach the electrical connector to each Singlet purple circles below Be sure the connectors are dry i Re screw on the two nuts to each Singlet Aluminum Stand 16 Ekctr
10. tail purchaser or licensee of the Super ActivO Purchaser that the Super ActivO will conform to and perform in accordance with the published technical specifications and any accompanying written materials supplied by ECOZONE and will be free from defects in materials and workmanship under normal use and conditions for the applicable warranty period indicated below This warranty does not extend to Super ActivO s that have been subject to misuse accident exposure to corrosive substances tampering or use in a manner not approved by ECOZONE in writing The Ozone Filtering Unit shown in the picture on page 18 as 17 is a consumable and is expressly excluded from this warranty Warranty period is 1 year commencing on the date of purchase Under this warranty Purchaser must first return the Super ActivO to ECOZONE together with proof of purchase from an authorized dealer of ECOZONE a Dealer either directly or through the Dealer from whom Purchaser purchased the Super ActivO for examination by ECOZONE of entitlement under the terms of this warranty All shipping handling travel service call and or other incidental and or related charges are fully payable by Purchaser only and are not included in this warranty In the case of machine s fault which requires reparation that can be done by the customer on his site but must be executed upon manufacturer s exclusive discretion at the manufacturer s facility or in the case of manufactur
11. ty standards The system incorporates ECOZONE s unique ADA system a double stage operating cycle that creates ozone and subsequently removes it allowing the immediate reoccupation of treated spaces In the first stage the room is enriched with ozone generated from the air using Ecozone s multi patented technology at a particularly high rate in order to reach homogeneous conditions and a high concentration level within the shortest possible time In the second stage any after treatment residual ozone is decomposed into oxygen so as to leave the treated room well within the regulated levels 2 Declaration of Conformity Model No POCS 500 POCS Portable Odour Control System This unit fully complies with CE amp FCC rules of EMC regulations EN 61000 61 EN 61000 62 EN 61010 1 EN 5501 EMC FCC Part 15 Safety of Low Voltage Directive 73 23 EEC as Amended EN 61010 1 Federal C Communications Commission Safety Precautions amp Warnings e Read this manual carefully before operating the unit WM Do not expose this equipment to rain or moisture Should any AS liquid come into contact with the system unplug it and have it serviced by qualified personnel before operating it further Unplug the system power plug when it is not in use When unplugging never pull the plug by the cord itself DO NOT enter the treated room during the operation of the system or before hearing the completion of cycle audio alert s
12. ut code 72 hours ozone generation only Control Digital keyboard Display LCD 16 Digits Safety Circuit breaker 5A Amber Flashing Light Indicator Super ActivO in operation Red Fault Indicator Buzzer Alarm operation has begun operation has ended Differential Pressure Regulator air flow obstructed Door Interlock front panel not closed Dimensions 50 x 40 x 100 cm with handle attached 66 x 53 x 94 cm packed for shipping handle detached Ozone outlet duct 4 diameter Weight 34 kg packed for shipment 40 kg Enclosure Metal and ABS Wheels leave no tracks Low EM Noise Certification CE amp FCC 5 3 Normal Environmental Conditions Indoor use only Temperature 5 C to 40 C Humidity maximum relative humidity 95 ECOZONE Technologies has a policy of continuous product improvement and reserves the right to modify or change this specification at any time without notice 4 Operation Preparation and Connections CAUTION OZONE IS A POWERFUL OXIDIZER USE THIS EQUIPMENT WITH CARE AND IN UNINHABITED AREAS ONLY READ ALL OPERATING INSTRUCTIONS BEFORE USING THIS MACHINE RE OCCUPY TREATED ROOM ONLY AFTER PRESET OPERATING TIME HAS ELAPSED AND THE AMBER FLASHING LIGHT HAS STOPPED FLASHING INDICATING THAT THE MACHINE IS NO LONGER IN OPERATION DO NOT ATTEMPT TO ENTER THE ROOM WHILE MACHINE IS IN OPERATION VENTILATE ROOM AFTER USE N A Connect power cord to socket on Super ActivO s rear panel bottom