Home

USER MANUAL - UsedLighting.com

image

Contents

1. 5 until the display shows SLA indicating operation in SLA SLAVE mode In this mode the unit is set to DMX channel 001 in order to receive the signals from a master unit of the Multiform LS series being in mode A or C The unit interprets CH1 as Out1 level CH2 as Out2 level and CH3 as Out3 level CH4 is not in use and the potentiometer 1 is disabled This mode can also be used for remotely controlling the unit if no specific DMX address is needed and channels 001 003 can serve as a default To indicate that the unit is controlled by an external DMX signal the DMX LED 3 is lit d Mode DMX Mode Press the MODE button 5 until the display shows d indicating operation in d DMX mode Shortly after that the display shows the DMX starting address You can choose any DMX starting address by simply using the UP DOWN buttons 6 7 The chosen DMX address comes effective approximately 3 seconds later and will show up on the display 2 in alternation to the d This allows control of the unit by any external DMX signal sending on the chosen channel In this mode the potentiometer 1 is disabled The unit receives DMX values on a packet of four channels and mirrors the received data on the DMX output 13 If a DMX signal is present the DMX LED 3 will turn on The four channels control the unit as follows DMX channel Value Range Function CH1 Outt level CH2 Out2 level CH3 Outs level CH
2. Shock hazard Equipment must be properly grounded WARNING Hot surface Risk of skin burn or skin irritation WARNING Fire hazard WARNING Laser radiation Risk of surface damage WARNING LED light emission Risk of eye injury Security advice before use gt eS D V1 00 05 2012 General advice Read this manual completely before using the product Keep this manual in your records for future reference Follow all instruction printed in this manual Follow all printed security advice on the product itself Take care of enough distance between this product and sources of hum and noise like electric motors and transformers Carry this product with greatest care Punches big forces and heavy vibration may damage this product mechanically a Protection from eye injury 1 Warning Depending on the configuration of the device this device may reach or exceed the limits of EN62471 risk group 2 and may hence reach to risk group 3 2 To avoid eye injury do not look into the beam from a distance of less than 8 5 m 27 ft 11 ins from the front surface of the fixture without protective eyewear such as shade 5 welding goggles At larger distances light output is harmless to the naked eye provided that the eye s natural aversion response is not affected 3 Do not view the beam directly with optical instruments such as magnifiers telescopes binoculars or similar optical instruments that may concentrate the li
3. be 30000 to 50000 hours or less if the LED is exposed to excessive heat which can be caused by continuously running all LEDs inside this device at full power and operating the unit in high environmental temperatures If improving the lifespan expectancy is a priority take care of providing for lower operational temperatures This may include forced external cooling and or the reduction of overall projection intensity m Unpacking Please check that the box contains the following items and contact your dealer immediately for replacement if any part is missing Main parts 1 pc Multispot HP LS1012 passive RGB LED panel 1 pc PSO20A 2 DMxX controlled 3 channel power supply 1 pc Power cord 1 pc Operation manual Getting started connecting assembly In case your dealer did not pre connect assemble the Multispot HP LS1012 passive RGB LED panel for you with the PSO20A 2 DMX controlled 3 channel power supply or any other compatible power supply you need to connect assemble it before use Risk of electric shock Do not connect the mains cable before the following steps are accomplished For assembly there are two basic choices 1 Fix the PSO20A 2 DMxX controlled 3 Channel power supply on a wall by using two screws at the correct distance which do not protrude more than 4mm from the wall surface Fix the screws on the wall first then slide the PSO20A 2 DMxX controlled 3 Channel power supply on the screws using the slots on the rear sid
4. decision Multiform is one of the leading global manufacturers of professional lighting equipment and has decades of experience in design production and quality assurance To meet your requirements this unit has been designed and built to the highest standards so that we can assure you that you have made a good and satisfying investment To take full advantage of all possibilities and for your own safety and the safety of your environment please read these operating instructions carefully before you start using the unit Description The MultiSpot HP LS1012 is a high power passive RGB LED panel designed to be combined with the PSO20A 2 DMxX controlled 3 output power supply or other compatible power supplies along with it constitutes a powerful yet compact light fixture for indoor applications which range from architectural purposes to stage lighting With its compact design high efficiency drive electronics and advanced cooling system this fixture has been designed for both flexibility and reliability SAFETY INFORMATION Read the safety precautions in this chapter before installing powering up operating or servicing this device Failure to do so may void the product warranty and releases the manufacturer from all product liability gt Symbols used in this manual The following symbols are used to identify important safety information on the product and in this manual WARNING Read manual before installation operation
5. installation area can hold a minimum point load of 10 times the device s weight e n fixed installations fix the unit with self locking screws nuts to the mounting point e When mounting the unit to truss be sure to secure an appropriately rated clamp to the hanging yoke using a M10 screw fitted through the center hole of the hanging yoke e Where required secure the installation with an appropriate safety cable Always use a certified safety cable according to DIN56927 that can hold 12 times the V1 00 05 2012 8 User Manual Multispot HP LS1012 amp PS020A 2 AV MULTIFORM weight of the device when installing the unit This secondary safety attachment should be installed in a way that no part of the installation can drop more than 20cm if the main attachment fails Never stand directly below the device when mounting removing or servicing the fixture Make sure the area below the installation place is free from unwanted persons during rigging de rigging and servicing The operator has to make sure that the safety relating and machine technical installations are approved by an expert before using them for the first time The installations should be re inspected every year Make sure to comply with applicable cooling requirements if any m Getting started making AC supply connections gt P Risk of fire Safety risk The Multispot HP LS1012 passive RGB LED panel and the PS020A 2 DMX controlled 3 Channel power supply requires a
6. 4 000 127 Master level Pp 128 227 Tact 128 slow 227 max speed 23Hz 228 255 Master level full on Tact off Addressing has to be done as follows 001 first device CH 1 4 factory default 005 second device CH 5 8 009 third device CH 9 12 013 fourth device CH 13 16 and so on This setting is stored even if the device is switched off V1 00 05 2012 13 User Manual Multispot HP LS1012 amp PS020A 2 AV MULTIFORM C Colour Mode Press the MODE button 5 until the first digit on the display shows C indicating operation in C mode Then choose by using the UP DOWN buttons 6 7 one of the 19 presets as shown in the list below Changing the setting becomes effective directly Knob 1 determines the output level In C mode the unit does not receive any values from the DMX input but generates related DMX values on the output according to the selected pattern so that other similar units from the Multiform LS series can show the same behaviour if they are connected by DMX signal cables and set to Slave Mode SLA NOTE The C Mode is automatically disabled and can not be chosen when an external DMX signal is received DMX indicator LED 3 is lit If you leave mode C for any reason and come back later into mode C the unit will recall the last chosen mix even if the unit was switched off in between Available colour presets C2 Out2 C12 Mixl c9 MixF C1
7. 9 All outputs full on V1 00 05 2012 12 User Manual Multispot HP LS1012 amp PS020A 2 AN MULTIFORM 4 The surface of the device may get hot during operation and heat sink areas may reach to or exceed the limits of EN60950 Do not touch heat sink areas of the device during operation and allow 20 minutes of cool down time after powering off before touching 5 If fluids have spilled into the unit or small parts have intruded the unit immediately switch off the unit and hand it over to the authorized service for a security check 6 Disconnect the unit from AC supply by pulling the AC plug out of the wall outlet or the unit s AC socket during a thunder storm in order to avoid any damage on the unit due to AC voltage peaks 7 In cause of not correct function of this unit or damaged AC cord or other damaged parts pull immediately the AC plug out of the wall outlet and hand the unit over to the authorized service for a security check 8 To meet all aspects of functionality and security during mainte nance work to be preformed on this unit all parts should be replaced by genuine spare parts Consequently take care of your dealer or maintenance company to be authorized by the manufacturer Health advice This unit produces and absorbs electromagnetic radiation The strength of radiation and the sensitivity for disturbing interference matches the CE and FCC requirements A corresponding sign is printed on the backside of the unit An
8. User Manual Multispot HP LS1012 amp PS020A 2 AN MULTIFORM DMX channel assignment overview Mode gt A C P P SLA DMX CH3 lt 50 CH3 gt 50 CH4 o Of Tact Tact bevelTact 0 m Maintenance This unit does not need regular maintenance The internal circuit is protected by a 250V 2A slow blow fuse 5x20mm fuse If this fuse fails this usually indicates an internal fault requiring servicing by a qualified engineer Technical data MULTISPOT HP LS1012 amp PS020A 2 Panels Output 250 caciieintaisiaic be cectabu taba ena Gessenctadeace daedshedstenet ce teeeads care 1 panel 1680 Im LED configuration 12x3W RGB 3 in 1 12 1W red 12x1W green 12x1W blue DUNS EPE EE S ae nee ee ee oe cee Secondary 25 degrees DMX Control amp Protocol cccc cece cece cena ee eeee eae enes 3 5 Channels DMX 512 1990 IP TRON arkcscasrctaudaracuanasumeaesneneuiessepouseincusskhstausuiaauataexendusesantanieaneeua 20 indoor PTA SUN sesio eee eE eae ESEESE eros AC100 250V 50 60Hz Power supply type max CONSUMPTION c cece cece e eee eeeeee ee eaaes switch mode 45W DMX COMING CLIONS a wis sacsiesine sa iaslaslaidun dee ERA AARSE 3 pin XLR Male Female Modulation FV DC utccrs venience aiiiverauvvenaniwonstassivawenss Pulse Density Modulation PDM Dimensions with straight bracket WxHxD 00000eee 269 0 x 275 7 x 115 0mm WY GIO iiag teat trade tadwecd e danke nce cob nde doce lonmnsuiamed ane ardiu
9. cabesa nn ibssus wnenancanies danke 2 8kg Standards This product complies with the following standards EU electrical safety cccccssececcseseeesseeeeeeeees EN60598 1 2008 EN60598 2 1 1989 EU General Saey site cied 36 chcteccne E E EN60598 2 1 7 EU photobiological Safety ccccccccccccsseeeeeeceeeeeeeseeseeeeaseeeeeseaeeeeeeseaneees EN 62471 2008 EU EMC ceeecceeeeeeeeeeennees EN55015 2006 A1 2007 EN61547 1995 A1 2000 E URON O S ae a EN61000 3 2 2006 EU CK GM peeso ised eka E epee eee eee ate eee EN61000 3 3 2008 US safety scac ceasadncnteare aiotaenieecidattdaceeanetecadaantatotansescacent esdenceeceaenteecona UL60065 U ENO oe sees eee ese E ee re eee eee eee tne FCC Part 15 This product meets both the EMC Directive 2004 108 EC and the Low Voltage Directive 2006 95 EC Ask your dealer or visit www multiform lighting com for more information V1 00 05 2012 16 USER MANUAL MULTISPOT HP LS1012 amp PSO20A 2 High Power RGB LED Panel DMX Controlled 3 Output Power Supply For firmware 50 010 0018 00110 1 00 LS series Revk ENGLISH Page 2 16 AIAN MULTIFORM Updated versions of this document may be available at WWW MULTIFORM LIGHTING COM RevA 05 2012 Order code 12 010 0253 80100 1 01 User Manual Multispot HP LS1012 amp PS020A 2 AN MULTIFORM a Introduction Dear customer congratulations on the purchase of a Multiform branded item and the trust having been put in us with this
10. d or reclined more than 45 degrees from being upright heatsink on top Do not operate the Multispot HP LS1012 passive RGB LED panel and the PSO20A 2 DMXxX controlled 3 Channel power supply in any closed environment smaller than 10cbm unless forced air convection is provided Getting started secure mounting The Multispot HP LS1012 passive RGB LED panel and the PSO20A 2 DMxX controlled 3 Channel power supply can be positioned for operation in various ways Floor standing operation e Turn the bracket to the lower side of the unit and fold out the second inlaying bracket e Place the unit in a secure position where it can neither be touched by anyone or could possibly become an objective for anyone to stumble e Make sure to comply with cooling requirements of the used power supply if any Hanging Rigging ceiling mounted operation Risk of injury Overhead mounting requires extensive experience like calculating working load limits knowledge installation materials and periodic safety inspection of all installation material and the unit If you lack such qualifications do not attempt the installation yourself Improper installation can result in body injury Be sure to complete all rigging and installation procedures before applying power to the unit e Leave the inner and outer bracket folded e The unit should be installed out of reach of people and outside areas where persons may walk by or be seated e Make sure that the
11. e Remove the cover of the PSO20A 2 DMxX controlled 3 Channel power supply and fix the wall screws through the holes provided in the units PCB Re fit the cover of the PSO20A 2 DMX controlled 3 Channel power supply Plug the optional extended connection cable into the PSO20A 2 DMxX controlled 3 Channel power supply on one side and the Multispot HP LS1012 passive RGB LED panel on the other side until the locking mechanism of the connector is secured Plug in the mains cable to the unit and verify the display V1 00 05 2012 6 User Manual Multispot HP LS1012 amp PS020A 2 AN MULTIFORM Upon the user s choice the unit can work stand alone or may be controlled by external DMxX controllers Available modes A Auto Mode Press the MODE button 5 until the first digit on the display shows A indicating operation in A AUTO mode Then choose your desired pattern by using the UP DOWN buttons 6 7 see list below Changing the setting becomes effective 1 second after the new setting is made to allow stepping through presets without previewing all intermediate presets NOTE The A Mode is automatically disabled and can not be chosen when an external DMX signal is received DMX indicator LED 3 is lit Whilst being in pattern A 1 static scene turning knob 1 determines the mix whereas being in one of the other 26 patterns knob 1 controls the speed or selects the sound activated function refer to below patte
12. ely Key lock Pressing the MODE button 5 for longer than 3 seconds locks all the buttons 5 7 and the potentiometer 1 The display shows LOC in alteration to the mode changing every 2 seconds Pressing the MODE button again for more than 3 seconds unlocks the button and potentiometer functions Please note If the display is in OFF mode it will take approximately 25 seconds before the display switches off It will be switched on again if any key is touched and will switch off again after 25 seconds if the keys are not unlocked by the procedure mentioned above Termination To avoid interference the last unit of a DMX chain should be terminated Therefore the DIP switch 9 of the last unit in the DMX chain must be switched ON Switch on condition The unit always returns to the last mode before it was switched off in DMX modes however DMX values are cleared if power is switched off DMX signal drop condition The device will retain the status that it was in before the DMX signal got lost but potential tact settings will be automatically cleared V1 00 05 2012 15 User Manual Multispot HP LS1012 amp PS020A 2 AN MULTIFORM P DMX Preset Mode If you want to run the pre programmed patterns and scenes by an external DMX controller you can use the DMX Preset Mode Press the MODE button 5 until the display shows P indicating operation in P DMX Preset mode Set the DMX starting address by simply usi
13. ght output 4 Ensure that during setup and DMX programming no persons are inside a 8 50m 27 ft 11 ins vicinity of the device s front surface to avoid that they may accidently be exposed to the light beam User Manual Multispot HP LS1012 amp PS020A 2 AN MULTIFORM 2 Where the mains plug or an appliance coupler is used as a dis connect device such device shall remain readily operable 3 To pull the AC Cord out of the wall outlet or the unit s AC socket never pull the cable itself but only the AC plug 4 Disconnect the unit from AC supply before any kind of cleaning on the product Use smooth and dry cloth only for cleaning 5 Do not expose this unit to any dripping or splashing liquids and do not place objects filled with liquids such as vases on the unit 6 Do not operate this unit near to open water or in high humidity 7 Choose the position of the AC cord according to the lowest risk of damage by foot steps or by squeezing it 8 Do not open the unit for service there are no user serviceable parts inside Warranty will be void in any case of unauthorized service by the user or other not authorized persons Protection from fire AAN 1 Take care of not placing the unit near sources of heat e g powerful amplifiers fog machines Protection from electric shock 1 Only connect this unit to a mains socket outlet with protective earth connection ground fault earth fault and overload protection 2 Allow a
14. n AC power source with sufficient power carriage and correct grounding to ensure safe operation The AC power source must be equipped with a circuit breaker and earth leakage detector Make sure to only use compliant AC supply lines Getting started making DMX control connections Connect the PSO20A 2 DMxX controlled 3 channel power supply to a suitable DMX controller where needed and interconnect several units by means of their DMX In Outputs as required The last unit shall be equipped with a proper 120 Ohm termination resistor equipped DMX plug as shown in below drawing Please make sure that all used DMX cables comply to below standard DMX output DMX output DMX input DMX input TERMINATION oe fF Jal SIGNAL SHIELD GROUND RETURN OV INNER CONDUCTOR DATA COMPLEMENT INVERTED Termination resistor INNER CONDUCTOR DATA TRUE NON INVERTED V1 00 05 2012 9
15. ng the UP DOWN buttons 6 7 The chosen DMX address comes effective approximately 3 seconds later and will show up on the display 2 in alternation to the P The unit receives DMX values on a packet of four channels and mirrors the received data on the DMX output 13 If a DMX signal is present the DMX LED 3 will turn on The four channels control the unit as follows If DMX value of channel 3 is lower than 50 the unit works with static colours DMX Channel _ Value Range 000 255 Output mix choice from presets see C mode 000 255 Master level 000 049 Static mix mode active 000 049 Tact off PL 050 255 Tact 050 slow 255 max speed 23 Hz Output mix presets can be activated by means of CH1 whilst the chosen mix can be adjusted with CH2 If the value of CH4 is above 50 the unit is set to tact mode The tact speed for any fixed output mix chosen on the first channel can be adjusted from zero value lt 50 to 23 cycles per second value 255 If DMX value of channel 3 is equal or higher than 50 the unit works in pattern mode CH1 Pattern CT CH _ Ssi Pattern Soft fade MixB MixC Hard switch MixD MixE Soft fade MixF MixG Hard switch Out1 Out2 Out3 121 135 Hard switch Out1 Out2 MixB Out3 MixC CH2 000 255 Level CH4 000 049 Tact off O 050255 Tact 050 slow 255 max speed 23 Hz V1 00 05 2012 14 User Manual Multispot HP LS1012 amp PS020A 2 AAN MULTIFORM D gt E gt EP gt WARNING
16. ode internal microphone 5 MODE selection button 6 UP button 7 DOWN button 8 Internal microphone 9 Switches on the termination for the last unit in the DMX chain 10 Switching the display on or off with delay 11 Maintenance not in use 12 Power Input 90 250V AC 13 DMX Output connector 14 DMX Input connector V1 00 05 2012 10 User Manual Multispot HP LS1012 amp PS020A 2 AV MULTIFORM shows A1 NOTE A1 is only shown if no external DMX signal is supplied to the unit Connect external DMX connections if any 2 Fix the PSO20A 2 DMxX controlled 3 Channel power supply on the back of the Multispot HP LS1012 passive RGB LED panel see illustration below Fix the screws to the Multispot HP LS1012 passive RGB LED panel into the provided mounting points first 1 leaving some clearance to slide on the PSO20A 2 DMX controlled 3 Channel power supply Then slide the PSO20A 2 DMxX controlled 3 Channel power supply on the screws using the slots on the rear side 2 Remove the cover of the PSO20A 2 DMxX controlled 3 Channel power supply and fix the screws through the holes provided in the units PCB Re fit the cover of the PSO20A 2 DMxX controlled 3 Channel power supply 3 Plug the provided connection cable into the PSO20A 2 DMxX controlled 3 Channel power supply on one side and the Multispot HP LS1012 passive RGB LED panel on the other side until the locking mechanism of the connector is secured Get the black plastic ca
17. or servicing WARNING Safety hazard Risk of injury or death WARNING Hazardous voltage Risk of severe or fatal electric shock gt D V1 00 05 2012 2 User Manual Multispot HP LS1012 amp PS020A 2 AN MULTIFORM The pre programmed soft fade or hard switching patterns can be chosen by means of CH1 whilst CH2 is used as a level channel CH3 allows to set the fade time or pattern speed from slow value 50 to very fast value 255 If channel 4 reaches a DMX value of 50 or above a tact function will be added to the chases The tact speed can be adjusted from slow value 50 to 23 pulses per second value 255 Note Whether the unit works in static mix mode or pattern mode only depends on the value of channel 3 So make sure the value of channel 3 is lower than 50 to be in static mix mode Otherwise you will be in pattern mode In this mode the potentiometer 1 is disabled Addressing has to be done as follows 001 first device CH 1 4 factory default 005 second device CH 5 8 009 third device CH 9 12 013 fourth device CH 13 16 and so on This setting is stored even if the device is switched off Display on off If you wish the display to be lit only when a change in operation is made the DIP switch 10 should be in the position off Now if any of the buttons is not pressed for more than approximately 25 seconds the display is switched off As soon as one of the buttons is pressed again the display switches on immediat
18. p fixed at the top end to cover the cable and to fix the power supply itself from sliding off Use the two black screws 4 Plug in the mains cable to the unit and verify the display shows A1 NOTE A1 is only shown if no external DMX signal is supplied to the unit Connect external DMX connections if any Note In some countries the Multispot HP LS1012 passive RGB LED panel may have been pre assembled with the PSO20A 2 DMxX controlled 3 channel power supply to facilitate out of the box usability In this case this assembly procedure is obsolete Getting started choosing a location Risk of fire The Multispot HP LS1012 passive RGB LED panel as well as the PSO20A 2 DMxX controlled 3 Channel power supply has been designed to work in dry indoor environments at environmental temperatures up to 35 degrees Celsius For proper operation the PSO20A 2 DMxX controlled 3 Channel power supply must be operated with its heatsink side up and unobstructed air convection to the heatsink V1 00 05 2012 7 User Manual Multispot HP LS1012 amp PS020A 2 AV MULTIFORM Note Do not operate the Multispot HP LS1012 passive RGB LED panel and the PSO20A 2 DMXxX controlled 3 Channel power supply in environments with more than 35 degrees environmental temperature or more than 75 relative humidity Do not operate the Multispot HP LS1012 passive RGB LED panel and the PSO20A 2 DMxX controlled 3 Channel power supply in any position incline
19. rn list The sound activated function can be activated by setting the knob 1 inside the first 10 degrees of its travel from left detent and it works from a built in microphone 8 which picks up the environmental sound Its activity is shown by the flashing of the right dot 4 in the display The level for all patterns is maximum In A mode the unit does not receive any values from the DMX input but generates connected by DMX signal cables and set to Slave Mode SLA If you leave mode A for any reason and come back later into mode A the unit will recall the last chosen pattern even if the unit was switched off in between Pattern list Function of Knob 1 None Mix Speed Speed Speed Speed Speed Speed Speed Speed 10 Sound activation Speed 1 Sound activation Speed Sound activation Speed Sound activation Speed P P P S P S P gt NI gt on BR oo ro a o gt oe gt z gt gt gt NO aa w rs V1 00 05 2012 11 User Manual Multispot HP LS1012 amp PS020A 2 AV MULTIFORM m Operation All user controls are located on the rear bottom and side of the PSO20A 2 DMX controlled 3 Channel power supply User interface overview _ In A Mode Speed Control except A1 Mix Control In C Mode Level Control 2 Display showing the Mode DMX address LOC function etc 3 Indicates presence of a DMX signal 4 Indicates the sound activated m
20. t least about 0 15m 6 ins between this unit and other devices or a wall to allow for proper cooling 3 Take always care of sufficient air convection in the unit s environment to avoid overheating Make sure air convection slots are not blocked Do not operate this unit in environmental temperatures exceeding 40 degrees Celsius 4 Be sure this fixture is kept at least 0 75m 30ins away from any flammable materials decoration etc 5 Do not stick filters masks or other materials directly on the LEDs or the LED cover screen 6 Check the total maximum power of your AC wall outlet if you connect several units to one wall outlet and avoid any overloading 7 If the device itself has an AC outlet for providing power to other units make sure to not exceed the specified maximum load Protection from injury and damage A N 1 Never use any accessories or modifications not authorized by the manufacturer of this unit l 2 Choose a location for operation where the unit is protected from AN vibration and where a fixed mounting position is provided In case of overhead mounting follow applicable rigging requirements 3 Before plugging the AC cord in the wall outlet check whether the AC plug the mains voltage and frequency are the same as this product is specified for If not contact you dealer immediately V1 00 05 2012 4 User Manual Multispot HP LS1012 amp PS020A 2 AAN MULTIFORM SLA DMX Slave Mode Press the MODE button
21. y change or modification may affect the behavior of the unit concerning electromagnetic radiation with the CE requirements eventually not to be met any more The manufacturer takes no responsibility in this case Functional advice This unit is immune to the presence of electromagnetic disturbances both conducted and radiated up to a certain level Under peak conditions the unit is classified to show a class C performance criteria and may encounter temporary degradation or loss of function which may need manual help to recover In such case disconnect the AC power from the unit and reconnect it again to recover u Environmental advice This unit is built to conform to the ROHS standards and the WEEE directive 2002 96 EC of the European Parliament and of the Council of the European Union Under these regulations the product shall not be discarded into regular garbage at the end of its life but shall be returned to authorized recycling stations LX V1 00 05 2012 5 User Manual Multispot HP LS1012 amp PS020A 2 AN MULTIFORM LED Lifetime advice LED lifetime is determined by the gradually declining brightness of a LED over time with a point of 50 brightness reduction marking the defined end of its lifetime The driving factor of this effect is the heat that the chip inside the LED is exposed to While a chip may under ideal circumstances reach to more than 100000 hours of lifetime the real world lifetime may only