Home

USER MANUAL - Mega Systems

image

Contents

1. Function Perform Function ESC ENTER DOWN UP 0000 This function allows you to set your DMX Start Channel First make sure you have a proper DMX connection from your controller using the 3 or 5 pin XLR con nection If there is no DMX connection the red LED indicator will flash If there is proper DMX connection the red LED indicator will be off To Set the DMX Start Channel press Enter Use the Down or Up to select the desired DMX Start Channel and press Enter to confirm your setting To reset the fixture press Enter Use the Up or Down for Yes or No press Enter to confirm your setting This function allows the unit to output DMX signal to operate the same as the Master unit All preset settings will be copied the other fixtures Press Enter Use the Up or Down for Yes or No press Enter to confirm your set ting Note All other fixtures must be connected via XLR Connection And must be put on DMX address Channel 001 This function allows the unit to activate the built in programs Press Enter Use the Up or Down for 000 001 or 002 press Enter to confirm your setting You can record a scene by selecting the performance function you want to use from O to 2 Then accessing the ManDim function and setting the desired intensi ty then press Enter to confirm The fixture was a capability to operate in 2 different modes of DMX control Mode 1CH is Dimmer Mode 2CH is Dimmer and Strobe Press Enter Use the Up or Down for 1CH
2. included Mechanical Specifications DMX Connectors 3 and 5 pin XLR connectors in out Power Connections Neutrik Power con In and Out Power Cable 4 Ft 7 Inch PowerCon to Nema 5 15 Cable Thermal Maximum ambient temperature 104 4 16 Maximum surface temperature 140 Display Digital LED Fastening System Mounting Yoke 12 Size 25 L x 10 5 W x 16 16 H Size 31 X 12 5 X 12 5 Weight 22 lbs Weight 25 lbs Electrical Specifications LED Type 1 COB LED EN LED Watts 200 LED Color Temp CW Cool White 5600K 8 5 WW Warm White 3200K CRI 285Ra LED AVG Lifetime 60 000 to 100 000 hours Zoom Manual Zoom from 20 to 45 Fan Heat Pipe Cooling with low noise fan s Power Consumption Universal 100 240V 50 60 Hz Ballast Electronic 8 25 10 5 with Knobs Power Consumption Watts 242 Amps 2 12 Control amp Programming Protocol DMX 512 DMX Channels 2 Operating Modes 1 Channel Dimmer 2 Channel Dimmer Strobe Operating mode Stand alone 255 step Dimmer setting via display Main Power Connection Caution if Do not connect fixture to a dimmer system 2 This unit has Auto switching power supply It will resoond to 110V or 220V automatically 3 This unit must be earthed electronically grounded 4 Replace fuse only with the specified type and rating The occupation of the connection cable is as follows This fixture is equipped with an electron
3. repaired under warranty will be returned to the owner with the freight prepaid by MSI via the most economical means of shipment Repair or replacement as provided for under this warranty is the exclusive remedy of the consumer MEGA SYSTEMS INC makes no warranties express or implied with respect to any product and Mega Systems specifically disclaims any warranty of merchantability or fitness for a particular purpose Mega Systems shall not be liable for any indirect inci dental or consequential damage including lost profit sustained or incurred in connection with any product or caused by product defect or the partial or total failure of any product regardless of the form of action weather in contract tort including negligence strict liability or otherwise and weather or not such damage was foreseen or unforeseen Warranty is void if the product is misused damaged modified in any way or for unauthorized repairs or parts This warranty gives you specific legal rights and you may also have other rights which vary from state to state Mega Lite 5718 Kenwick St san Antonio TX 78238 Ph 210 684 2600 Fax 210 855 6279 www mega lite com info mega lite com
4. MEGAG DRAMA LED USER MANUAL Table of Contents Safety Information Specifications Main Power Connection DMX 512 Connection A e e joc CO ER e A Main Control Menu Rigging the I atrapan Cleaning amp Maintenance cccccccsseccseeeceeeceeeceeeceeesaeeeeeeesueeseueesseesaaeess Parts List 8 Check that the unit has not been damaged during transport Read all cautions and warnings prior to operation of this equipment Protection Against Fire Fire Maintain a minimum of 1 foot distance from any type of flame Replace fuse only with the specified type and rating Do Not install the unit to close to a heat source Make sure cable are properly secured away from unit movement Maximum surface operating temperature 104 D o E goa Protection Against Fire A Electrical Disconnect power before servicing For connection to main power supply proceed to page 5 This unit must be earthed electronically grounded Do not expose unit to rain or moisture a a a Protection Against Mechanical Hazards 1 Use safety chain when hanging unit ak 2 Use quality clamps or bolts when positioning unit 3 Do not open unit while it is on risk of electrical shock Mechanical Technical Information Part Numbers Fixture 7035 CW Drama Z Wide Cool White 200 Cool White 7035 WW Drama Z Wide Warm White 200 Warm White 7030 GH Removable Gobo Holder accessory included 7030 JH Removable Gel Holder accessory
5. ed 2 There must not be any deformations on the housing fixation and installation spots ceiling suspension trussing 3 The electronic power supply cables must not show any damages material fatigue e g porous cables or sediments Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed Note There is no serviceable parts inside the device except for the LED s Maintenance and service operations are to be carried out by authorized dealers Replacing the fuse Only replace the fuse with the same type and rating F3 15AL250 Replacing the power cable If the power cable of this device becomes damaged it has to be replaced by author ized dealers or trained professional only Should you have further questions please contact your dealer Parts List Warranty Information Warranty Conditions Unless otherwise stated in writing your product is covered by a one year parts and labor limited warranty LEDs are not guaranteed to match in color temperature or output It is the owner s responsibility to furnish receipts or invoices for verification of purchase date and reseller or distributor If purchase date cannot be provided date of manufacture will be used to determine warranty period Goods returned under warranty must follow the proper authorization procedure and must be accompanied by a copy of the original invoice Goods
6. ic power supply that will let the unit operate from 100V to 240V from 50Hz to Cable USA Cable EU Z L 110V Connection 220V Connection L e amp a DMX 512 Connection The fixture is equipped with 3 pin XLR Sockets for DMX input and output The sockets are wired in parallel Only use a shielded twisted pair cable designed for RS 485 and 3 pin XLR plugs and connectors in order to connect the controller with the fixture or the fixture with another DMX input DMX output 1 Shield l ML 2 Signal Caution 5 N A At the last fixture the DMX signal needs to be terminated with a terminator Solder a 120 Ohm resistor between the and the signal into a 3 pin XLR plug and plug it in to the last fixture on the signal run Pre manufactured terminator plugs are availa ble for purchase from your Mega Lite dealer P DMXT DMX Profile Drama Z 200 W Mode 1 CH DMX Chanel LED intensit 0 255 Drama Z 200 W Mode 2 CH DMX Chanel LED intensit 0 255 Pulse Off slow to fast 160 191 Random Strobe slow to fast 192 255 NoFunction Strobe slow to fast 1 127 2 Strobe Pulse On slow to fast 128 159 Main Control The control board on the fixture base is your interface to access and control all the functions on the unit It s digital display gives you a code view of the options and functions The following will explain each func tion and its options Reset Function Master
7. or 2CH press Enter to confirm your setting This function let you set the Dimmer intensity via display Press Enter Use the Up or Down from 000 to 255 press Enter to confirm your setting Operating Software Rigging the fixture Caution 1 The installations must be carried out by an authorized dealer or trained profes sional 2 Unit may cause severe injures if you have doubts concerning the safety do not install When rigging a unit it is very important that you follow common safety procedures Rigging requires extensive experi ence including but not limited to calculating working loads material being used and periodic safety inspections If you lack these qualifications do not attempt the installation yourself instead use a professional structural rigger When rigging the unit always be secured with a secondary safety attachment The installation location of the projector has got to be built in the way that it can hold 10 times the weight for 1 hour with out any harming Installation should be checked at least one time a year by a skilled person Cleaning and maintenance Installation Maintenance The operator has to make sure that the unit is operating safely and has the installa tions and electronics checked by an expert every 2 years The following points have to be considered during the inspection 1 All screws used for installing the device or part of the device have to be tightly connected and must not be corrod

Download Pdf Manuals

image

Related Search

Related Contents

  Desa GVC65PA User's Manual  User Manual - Wayne Reaves Software  Poulan 199340 Snow Blower User Manual  Goodram 2GB DDR2 SO-DIMM  Samsung 731BF Brugervejledning  ASUS B400V LT7602 User's Manual  Opus 100 Mk II  RCA RP5620 Clock Radio User Manual  

Copyright © All rights reserved.
Failed to retrieve file