Home

TBS 1m range Card Reader User Manual

image

Contents

1. 2 beeps 5 3 1 3 digit index code Range from 001 999 card can be deleted by this code 5 3 2 When the enrolling multiple cards every card index code will be calculated in order For example card one s index code is 015 card two s will be 016 5 4 Delete valid Card 5 4 1 delete by index code Press 7 3 digit code1 2 beeps 3 digit code2 2 beeps 3 digit code n 2 beeps 2 beeps 5 4 2 Delete by presenting Card Press 7 presenting card1 beep 2beeps presenting card 2 beep 2beeps presenting card n beep 2beeps 2 beeps 5 4 3 Delete all cards Please restore the factory default 5 5 Exit programming Mode Press 2 beeps 5 6 Open Door Mode 5 6 1 card or code mode Press 1 0 2 beeps 5 6 2 card personal code mode Press 1 1 2 beeps 5 7 Code 5 7 1 code include personal code and public code 5 7 2 Disable changing personal code Press 1 2 2 beeps 5 7 3 Enable Changing personal code Press 1 3 2 beeps 5 7 4 Change Personal code not under programming mode Press for 5 seconds show card input 4 digit old code input 4 new digit code confirm the new code 2 beeps 5 7 5 Change public code Press 3 4 digit code defaulted 1234 When the public pin is 0000 the pin is avail in card or pin mode 5 8 Change Door Open Time Press 2 TT TT stands for the delay time such as door open time is 3 seconds then TT 03 5 9 Anti break alarm 5 9 1 closed anti break alarm press 4 0 5 9
2. 2 Open anti break alarm press 4 1 5 10 Door contact sensor 5 10 1closed door contact sensor press 6 0 5 10 2 Open door contact sensor press 6 1 5 11 Door sensor alarm 5 11 1 Close sensor alarm press 8 0 5 11 2 Open sensor alarm press 8 1 After turning on this function the controller will give off continuous long beep when the door is not closed after normal opening or the door is not opened through the controller 5 12 Alarm delay time Press 82 TT TT is time interval in second For example if the delay time is 3 seconds then TT 03 When the door is locked TT seconds if the door contact sensor is in alarm status the controller is in alarm mode This function should be used when the door sensor alarm is on 6 Restore factory default Press 9 86 there will be 2beeps 3 beeps and 3beeps after 5 seconds then the factory defaults are restored 7 User s instruction 7 1 card or pin mode 7 1 1 The pins should be entered in 2 seconds 7 1 2 Press ff key o cancel pin input 7 2 card Private Pin mode 7 2 1 Reading card 2 beeps Private Pin 7 2 2 Press key to cancel pin input 8 Reset programming pin See Wiring Diagram Notes 9 FAQ Symptom Possible solutions After the lock is opened there are 8 short beeps The controller needs higher voltage the power supply should be checked The card reading distance is short or cad cannot be 1 If the controller is on metal s
3. IStanalone Controller MT601 User Manual 1 Product Specification Item specification power DC12V 10 1 2A Lock Relay 12VDC 2A Temperature working 0 C gt 45 C storage 10 C 55 C Relative Humidity working 40 90 RH storage 20 90 RH User Capacity 1000 Frequency 125KHz or 13 56Mhz Card Type EM card Read range EM 5 15cm External Reader One extra W26 reader Other Connections Lock exit button bell door sensor alarm 2 Factory Defaulted Set Item Defaulted Value Programming Code 881122 Open Door Mode Card or public code 1234 Door open time 3 seconds Anti break Alarm able Door Magnet Alarm disabled lock status disabled Alarm delay 0 second Change Personal Code Function disabled 3 the LED and Buzzer 3 1Normal working status 3 1 1 Valid command short beep 3 1 2 In valid command long beep 3 2Programming state 3 2 1Green LED on 3 2 2 Valid command two short beeps 3 2 3 In valid command Three beeps 4 Cancel Command Press key to cancel command before finish it 5 Functions amp Setup 5 1 Enter the programming mode Press 6 digit code default 881122 5 2 Modify the programming pin Press 0 new 6 digit pin confirm the new 6 digit pin 5 3 Enroll card Press 5 3 digit index code 2beeps card 1 Beep two beeps card 2 Beep two beeps card n Beep two beeps
4. urface it should be moved to other place Read 2 Check the power supply After reading card there are 3 beeps and lock is not open 1 It s in card pin mode 2 key is pressed wait for 5 seconds to present the card The enrolled card cannot open the door 1 Check if the door sensor is in alarm status 2 Disable the door sensor alarm Press programming pin there is long beep and cannot enter the programming mode Other keys are pressed before pressing the key Keep on pressing key after long beep then enter the programming mode again Press key there is long beep and cannot enter the programming mode Other keys ate pressed before pressing the key Keep on pressing key after long beep then press the programming key again Press 5 there are 3 beeps The controller has full card capacity Press 5 index code 3 beeps This index code is in use select another index code Press 5 index code 2 beeps presenting card 3 beeps This card is in use The controller exit programming mode In programming mode if there is no input in 20 seconds the controller exits programming mode automatically 10 Wiring Diagram

Download Pdf Manuals

image

Related Search

Related Contents

Copyright © All rights reserved.
Failed to retrieve file