Home

Temperature / Humidity Data Logger DR

image

Contents

1. value of Humidity value display Minimum value of Humidity Temperature value Temp Max Min Maximum value of Temp value display M e Minimum value of Temp Ky i Humidity value Humidity Alarm Hi A value of Humidity value display A nin Lo A value of Humidity H Temperature value Temp Alarm Hi A value of Temperature value display Lo A value of Temperature M Troubleshooting Issue Data Logger Frozen Possible Cause 1 Either unplug data logger from DFC 201U or Unplug USB cable from PC when processing data download or other setting 2 button be pressed for a long time 3 Battery power exhausted The data logger will stop recording automatically when power is less than 10 but user still could download data Solution Please contact your local distributor or our service department X There is no user serviceable components inside the DR 20 series Do not attempt to disassemble the data logger The wrong operating could cause damage Only a factory qualified person should change and properly dispose of the data logger N Precautions a This instrument with waterproof function please avoid using it in a high temperature environment or with corrosive materials to avoid leakage or damage b When taken out put in the logger to a huge temperature varies environment the difference range will more over than specifications indicate because of the dew on the logger s surface Please place the logger on well
2. 22D Lo b and blink simultaneously e a 2 DR 20 22 ae Green and Red LED blink simultaneously ADR 20D 22D aDR 20 22 G Quick Start Guide gt lt Detailed of software applications please refer to DFC 201U Software Manual 1 Install software DFC 201U Ver1 05 1 1 Connect the USB flash drive to computer 1 2 Double click Setup on the USB contents screen to install DFC 201U software 2 Connect the Data Logger X Depending on your operating system version and other factors the PC may not be able to detect the data logger automatically Please restart the software again 2 1 Attach the logger to PC via DFC 201U docking station and interface cable Please rip off the Remove before use sticker 2 2 Double click Q DFC 201U Ver1 05 to execute software 2 3 Click o or 5 to connect data logger to PC it will automatically detect the identity and content of the logger which including Model no S N Record Location Number of Records Sampling rate Start End Time Click a to connect with logger automatically Select model number amp COMPORT and Click Y to connect with PC 3 3 Set the Data Logger 3 1 Click Set_on the dialog box to setting the desired start parameters for your application please make sure the old data is cleared 3 2 Click Start on the Data Logger Set dialog box to start recording 3 3 Click on the main screen to disconnect the data logger from computer 4 Download Clear Set func
3. DFC 201U software As described below 4 Stop Recording Connect the logger to PC via DFC 201U docking station and USB interface cable Press amp or click Device gt Stop to stop data logging When the memory capacity is full or the battery is exhausted the logger will stop recording Power Saving X The logger is built in long effectiveness battery The power life can be maintained for several years under correct operation as the following precautions 1 Please do not turn on LCD display frequently The data logger can achieve power economized status when it is not displayed 2 Based on your need to extend the sampling interval 3 Please do not plug the data logger on docking station when the data logger is not in use 4 User could press button to display the measurement value for 3 seconds even you turn off the display function 5 Alarm warning will consume a lot of battery power please STOP the logger via software to shut down the alarm warning 6 Please stop logger and storage it at normal temperature and dry place when the logger is not in use J Operation of LCD display type DR 20D 22D 1 Display Mode Device Set tick Display function box The recording values will display in LCD continuously while recording Display type only User could press and hold button for 5 seconds to turn off LCD display Press button again to turn on LCD display 2 None Display mode Default Device gt Set NOT tick Display functio
4. ventilated environment for a while then it will be restored to normal c In order to connect the Logger with computer the optional docking station DFC 201U kit is necessary d Do not press or stab to the breathable waterproof membrane which is on front of logger s right side Please also avoid letting it stain with oil or viscous substance e Do not put the logger in a location of strong electric or electromagnetic wave to avoid the logger s circuit is damaged f The connection endpoint three metal dots is the main channel to connect with computer please try to keep it clean g Please keep the temperature Humidity steadied at least 10 minutes to get a more accurate measured value h When the logger is not in use for a long time please put the logger and its accessories in the protective case please storage it in a clean and dry environment and please avoid directly sunlight i Please keep the logger away from children to avoid the occurrence of accidents j The logger has one year warranty Guarantee will not apply to the damages caused by nature disasters faulty usages or consumable purposes k If there are any operation questions or malfunction please contact your local distributor or our service department X Be sure to comply with the required regulations of battery recycling DR 20 Series specifications Model No DR 20 DR 20D DR 22 DR 22D Measuring Temperature Temperature 40 85 C Range 40
5. 85 C 40 185 F Humidity 0 100 RH 0 5 C 0 9 F 43 RH Accuracy 0 5 C 0 9 F at 20 80 RH Temp 25 C 5 C 1 1 0 1 C 0 1 F 0 1 C 0 1 F 0 1 RH 500 000 readings 250 000 readings per channel DR 20 DR 22 1 Red amp Green LED Indicator Display DR 20D DR 22D 1 Red amp Green LED Indicator 2 LCD Display Temperature Humidity Max Min Hi Lo Alarm Memory Battery capacity icon Sensor Precision semiconductor sensor Sample Rate 1 second to 24 hours 10 years typical at 25 C 15 minute sampling rate and turn off the Battery Life display alarm function Main Three start modes Instant start Button start Delay start Feat Real Time Red Green LED indicator Hi Low Alarm settings Build in eatures S N IP 65 Dust amp Splash proof 80X53X16mm Weight DR 20 22 54g DR 20D 22D 60g Approvals RoHS CE IP65 Specifications are subject to change without notice Required Accessories Including USB Docking station USB Flash Drive for software amp DFC 201U KIT manual and USB Computer interface cable
6. Raritan can t 11 Save Save the settings into data logger Do not Start Save the setting only 12 Start Select start method 9 and click Start to start tart Exit recording 11 12 13 13 Exit Click Exit to close Data Logger Set dialog box H Start amp Stop Logging 1 Instant Start On main screen s toolbar click Device gt Set setting the desired start parameters for your application tick Instant Start function box then click Start to start recording 2 Delay start On main screen s toolbar click Device gt Set tick Delay Start function box to unlock delay start timer and set the length of delay time The timer can be set up to 99 days 23 hours and 59 minutes Press Start to begin the countdown 3 Button Start On main screen s toolbar click Device Set tick Button Start function box and then click Start to finish setting The data logger will in a dormant standby state Press button on the Logger for 3 seconds to start recording Red amp Green LED will light up Delay Start Button Start r amp Download clear Sampling R lt Before start recording please check there are no data in the logger and finish setting the desired start parameters XW hile finish setting and start recording please do not unplug the logger from DFC 201U docking station until the remind message box show up X To avoid occurring any accident which is caused by wrong operation the logger can only be stopped via
7. Temperature Humidity Data Logger DR 20 series Instruction Manual Regarding the operation of software and USB Docking station please refer to DFC 201U Software Operation Manual A Standard Equipment Unpack and inspect the contents of the container Please check all the items listed below are included in the carton e DR 20 series Data Logger Instruction Manual Please note that DFC 201U Optional is a necessary accessory for DR 20 series to setting the relative functions in PC DFC 201U Kit includes the following accessories e DFC 201U USB Docking station e DR USB S USB Flash driver for software e DR USB W USB computer interface cable e DR 1 05M Software Ver 1 05 and User s manual B Initial status of DR 20D DR 22D The brand new DR 20D DR 22D can t function until user connects it to PC and set the related setting Please press button which is in the lower left corner of the data logger to confirm the logger can work well X Press button one time to observe the LCD content it will display for 3 seconds X Press button continually to scroll through the content as the following flowchart C Instrument descriptions Multi Function LCD Display Start Button l Power Indicator Green LED l e23 Alarm Indicator Red LED D4 Breathable Waterproof Membrane z Serial No H Connection Endpoint 7 Hang Hole CONOOKRWND gt NOTE _ 1 Do not damage or obstruct Breathable waterpro
8. n box User could press button to display the measurement value for 3 seconds even turn off the display function K Real Time Display X Real Time record mode only available when connected data logger to PC 1 The data logger display type will update the real time value on PC synchronous 2 The data logger display type will show up blink r t symbol if user unplugs the logger while processing real time function There are three ways to deal with it 2 1 Re plug logger to docking station within 30 seconds to continue real time function 2 2 Press button within 30 seconds to stop real time function instantly 2 3 The data logger will stop real time function automatically if user unplug data logger from docking station over 30 seconds L LCD Display Flowchart 1 DR 20D l ___ Temperature Max Min Values lt _ Temperature Alarm Values LCD Display of DR 20D described as below Display content LCD Display Temperature value Temperature Max Maximum Temp value Min value display Minimum Temp value Temperature value Temperature Alarm Hi A of Temperature value value display a Lo Lo A of Temperature value ue 2 DR 22D Humidity and Temp Humidity Max and Min Temp Max and Min Temp Alarm Humidity Alarm The LCD Display of DR 22D described as below Display content LCD Display Humidity Temp Humidity value value display Temperature value Humidity value Humidity Max Min Max
9. of membrane 6 to ensure the logger can keep its accuracy 2 Before using the logger please remove the Transparent protective sticker which is pasted on the connection endpoint D aBreathable aProtective Membrane sticker D Display descriptions DR 20D 22D LILA HIA MAX LoA MIN Oooo OC ee EE O a a a a E B C A Digit zone CIFE C Celsius F Fahrenheit Relative humidity units X User could turn on off the LCD display function via software Please refer to DFC 201U Software Operation Manual X Turn off LCD display function will help user with saving battery power User could press button to display the measurement value for 3 seconds even you turn off the display function 2 E LED Indicator 1 Power Indicator Green LED The green LED indicator will blink at 10 second intervals to indicate the logger is in action 2 Alarm Indicator Red LED User could set up alarm range in the software the alarm warning red LED indicator blink at 10 second intervals while the alarm range is out of user setting x Please STOP the logger via software to shut down the alarm warning X Alarm warning will consume a lot of battery power e eo ex e AGreen LED Indicator aRed LED Indicator F Power Shortage Warning an X The data logger will stop recording while the battery power is less than 10 Please download the record data immediately 1 DR 20D
10. tions Download Download record data to software the data is not saved to PC yet Clear Clear record data Please do not unplug the logger until clear function finished The Red LED warning indicator on the data logger will flash quickly when cleaning data To clear data logger s record data Device Clear Device Data Set Setting the desired start parameters for your application To set start parameters Device Set As DFC 201U Record System Ver1 05 File Device Language About Start i B00 con7 y mes UU Number o a Data li o Software Data mping 1 Sampling Rate 1 second to 24 hours available 2 Temperature Unit C or F Mz Data Logger Set 3 Location Register storage location up to 10 letters Sampling Rate 1100 15 00 4 Display Tick the Display function box to display the Temperature Unit aideg c recording values on LCD Location Enalish Oni SIRixen English Only Rixen 5 Tick Alarm function box to unlock the Hi A Lo A function E Display Display Type Only 6 Hi A Lo A Setting Hi A high point alarm and Lo A low point alarm 7 CAL Click CAL to unlock the REF function 8 Delay Tick Delay Start function box and select desired 5 Alarm 8 delay start time Delay Day Hour Minute 9 Start option Instant Start Delay Start Button Start oo FZ Joo zoo 10 Tick this function box and click Save to save settings JEU at i Delay Start gt 9 but not start recording